Loading...
HomeMy WebLinkAboutNC0025321_Application (ATC)_20210414 APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC-12-14) Application for Authorization to Construct Permit (FORM ATC-12-14) Page 1 State of North Carolina Department of Environmental Quality Division of Water Resources SECTION 1: INSTRUCTIONS AND INFORMATION A. The Division of Water Resources will accept this application package for review only if all of the items are provided and the application is complete. Failure to submit all of the required items will result in the application package being returned as incomplete per 15A NCAC 02T .0105(b). B. Plans and specifications must be prepared in accordance with 15 NCAC 02H. 0100, 15A NCAC 02T, North Carolina General Statute 133-3, North Carolina General Statute 143-215.1, and Division of Water Resources Minimum Design Criteria for NPDES Wastewater Treatment Facilities. C. The plans and specifications submitted must represent a completed final design that is ready to advertise for bid. D. Any content changes made to this Form ATC-12-14 shall result in the application package being returned. E. The Applicant shall submit ONE ORIGINAL and ONE DIGITAL COPY (CD) of the application, all supporting documentation and attachments. All information must be submitted bound or in a 3-ring binder, with a Section tab for each Section, except the Engineering Plans. F. Check the boxes below to indicate that the information is provided and the requirements are met. G. If attachments are necessary for clarity or due to space limitations, such attachments are considered part of the application package and must be numbered to correspond to the item referenced. H. For any project that requires review under the State Environmental Policy Act (SEPA), an Authorization to Construct cannot be issued prior to the completion of a State Clearinghouse advertisement period for a FONSI, EIS, etc. unless the project qualifies for a Determination of Minor Construction Activity. I. For more information, visit the Division of Water Resources web site at: https://deq.nc.gov/about/divisions/water-resources/water- resources-permits/wastewater-branch/npdes-wastewater/authorization-to-construct. J. In addition to this Authorization to Construct, the Applicant should be aware that other permits may be required from other Sections of the Division of Water Resources (for example: reclaimed water facilities permits; Class A or B biosolids residuals permit). SECTION 2: APPLICANT INFORMATION AND PROJECT DESCRIPTION A. APPLICANT Applicant’s name Town of Waynesville Signature authority’s name per 15A NCAC 02T .0106(b) Rob Hites Signature authority’s title Town Manager Complete mailing address 16 South Main Street, Waynesville, NC 28786 Telephone number 828.452.2491 Email address rhites@waynesvillenc.gov B. PROFESSIONAL ENGINEER Professional Engineer’s name Keith Webb Professional Engineer’s title Vice President North Carolina Professional Engineer’s License No. 12809 Firm name McGill Associates, P.A. Firm License number C-0459 Complete mailing address 55 Broad Street, Asheville, NC 28801 APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC-12-14) Application for Authorization to Construct Permit (FORM ATC-12-14) Page 2 State of North Carolina Department of Environmental Quality Division of Water Resources Telephone number 828.252.0575 Email address C. NPDES PERMIT NPDES Permit number NC0025321 Current Permitted flow (MGD) – include permit flow phases if applicable 6 MGD D. PROJECT DESCRIPTION Provide a brief description of the project: installation of an influent Parshall flume, installation of primary treatment including dual-channel screens, vortex grit removal system, and primary disc filters; installation of an influent pump station; rehabilitation of aeration basins, replacement of diffusers, and installation of new blowers, demolition of two primary clarifiers and installation of two 100-ft clarifiers, conversion of the intermediate pump station to return activated sludge/wastewater activated sludge station, modification of chlorine contact basins, conversion of gas disinfection and dechlorination systems to liquid chemical systems, installation of effluent reuse pump station, replacement of thickening mechanisms in two gravity thickeners, replacement of existing 1.5-meter belt filter press to a new 2-meter belt filter press, installation of a septage receiving station and a scum holding tank, installation of two electrical and control buildings, installation of system transfer and backup generator, and installation of PLC based instrumentations and controls package for monitoring and operating treatment facilities. SECTION 3: APPLICATION ITEMS REQUIRED FOR SUBMITTAL FOR ALL PROJECTS A. Cover Letter The letter must include a request for the Authorization to Construct; the facility NPDES Number; a brief project description that indicates whether the project is a new facility, facility modification, treatment process modification, or facility expansion; the construction timeline; and a list of all items and attachments included in the application package. If any of the requirements of 15 NCAC 02H. 0100, 15A NCAC 02T, North Carolina General Statute 133-3, North Carolina General Statute 143-215.1, and Division of Water Resources Minimum Design Criteria for NPDES Wastewater Treatment Facilities are not met by the proposed design, the letter must include an itemized list of the requirements that are not met. B. NPDES Permit Submit Part I of the Final NPDES permit for this facility that includes Part A (Effluent Limitations and Monitoring Requirements) for the monthly average flow limit that corresponds to the work that is requested for this project. C. Special Order by Consent If the facility is subject to any Special Orders by Consent (SOC), submit the applicable SOC. Not Applicable. D. Finding of No Significant Impact or Record of Decision Submit a copy of the Finding of No Significant Impact or Record of Decision for this project. Provide a brief description of any of the mitigating factors or activities included in the approved Environmental Document that impact any aspect of design of this project, if not specified in the Finding of No Significant Impact or Record of Decision. ___________________________________________________________________________________________ ___ APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC-12-14) Application for Authorization to Construct Permit (FORM ATC-12-14) Page 3 State of North Carolina Department of Environmental Quality Division of Water Resources Not Applicable. E. Engineering Plans Per 15A NCAC 02T .0504(c)(1), submit one set of detailed plans that have been signed, sealed and dated by a North Carolina Licensed Professional Engineer. Per 21 NCAC 56 .1103(a)(6), the name, address and License number of the Licensee’s firm shall be included on each sheet of the engineering drawings. Plans must be labeled as follows: FINAL DRAWING – FOR REVIEW PURPOSES ONLY – NOT RELEASED FOR CONSTRUCTION. 15A NCAC 02H .0124 requires multiple (dual at a minimum) components such as pumps, chemical feed systems, aeration equipment and disinfection equipment. Is this requirement met by the design? Yes or No. If no, provide an explanation: _____________________________ ___ ____ ____ Plans shall include: Plans for all applicable disciplines needed for bidding and construction of the proposed project (check as appropriate): Civil Not Applicable Process Mechanical Not Applicable Structural Not Applicable Electrical Not Applicable Instrumentation/Controls Not Applicable Architectural Not Applicable Building Mechanical Not Applicable Building Plumbing Not Applicable Plan and profile views and associated details of all modified treatment units including piping, valves, and equipment (pumps, blowers, mixers, diffusers, etc.) Are any modifications proposed that impact the hydraulic profile of the treatment facility? Yes or No. If yes, provide a hydraulic profile drawing on one sheet that includes all impacted upstream and downstream units. The profile shall include the top of wall elevations of each impacted treatment unit and the water surface elevations within each impacted treatment unit for two flow conditions: (1) the NPDES permitted flow with all trains in service and (2) the peak hourly flow with one treatment train removed from service. Are any modifications proposed that impact the process flow diagram or process flow schematic of the treatment facility? Yes or No. If yes, provide the process flow diagram or process flow schematic showing all modified flow paths including aeration, recycle/return, wasting, and chemical feed, with the location of all monitoring and control instruments noted. F. Engineering Specifications Per 15A NCAC 02T .0504(c)(2), submit one set of specifications that have been signed, sealed and dated by a North Carolina Licensed Professional Engineer. Specifications must be labeled as follows: FINAL SPECIFICATIONS – FOR REVIEW PURPOSES ONLY – NOT RELEASED FOR CONSTRUCTION. Specifications shall include: Specifications for all applicable disciplines needed for bidding and construction of the proposed project (check as appropriate): Civil Not Applicable APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC-12-14) Application for Authorization to Construct Permit (FORM ATC-12-14) Page 4 State of North Carolina Department of Environmental Quality Division of Water Resources Process Mechanical Not Applicable Structural Not Applicable Electrical Not Applicable Instrumentation/Controls Not Applicable Architectural Not Applicable Building Mechanical Not Applicable Building Plumbing Not Applicable Detailed specifications for all treatment units and processes including piping, valves, equipment (pumps, blowers, mixers, diffusers, etc.), and instrumentation. Means of ensuring quality and integrity of the finished product including leakage testing requirements for structures and pipelines, and performance testing requirements for equipment. Bid Form for publicly bid projects. G. Construction Sequence Plan Construction Sequence Plan such that construction activities will not result in overflows or bypasses to waters of the State. The Plan must not imply that the Contractor is responsible for operation of treatment facilities. List the location of the Construction Sequence Plan as in the Engineering Plans or in the Engineering Specifications or in both: Specification Section 011000 Summary H. Engineering Calculations Per 15A NCAC 02T .0504(c)(3), submit one set of engineering calculations that have been signed, sealed and dated by a North Carolina Licensed Professional Engineer; the seal, signature and date shall be placed on the cover sheet of the calculations. For new or expanding facilities and for treatment process modifications that are included in Section 4.C, the calculations shall include at a minimum: Demonstration of how peak hour design flow was determined with a justification of the selected peaking factor. Influent pollutant loading demonstrating how the design influent characteristics in Section 4.B.2 of this form were determined. Pollutant loading for each treatment unit demonstrating how the design effluent concentrations in Section 4.B.2 of this form were determined. Hydraulic loading for each treatment unit. Sizing criteria for each treatment unit and associated equipment (blowers, mixers, pumps, etc.) Total dynamic head (TDH) calculations and system curve analysis for each pump specified that is included in Section 4.C.6. Buoyancy calculations for all below grade structures. Supporting documentation that the specified auxiliary power source is capable of powering all essential treatment units. APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC-12-14) Application for Authorization to Construct Permit (FORM ATC-12-14) Page 5 State of North Carolina Department of Environmental Quality Division of Water Resources I. Permits Provide the following information for each permit and/or certification required for this project: Permit/Certification Not Applicable Date Submitted Date Approved Permit/ Certification Number If Not Issued Provide Status and Expected Issuance Date Dam Safety x Soil Erosion and Sediment Control May 2021 June 2021 USCOE / Section 404 Permit x Water Quality Certification (401) x USCOE / Section 10 x Stormwater Management Plan May 2021 June 2021 CAMA x NCDOT Encroachment Agreement x Railroad Encroachment Agreement x Other: x J. Residuals Management Plan For all new facilities, expanding facilities, or modifications that result in a change to sludge production and/or sludge processes, provide a Residuals Management Plan meeting the requirements of 15A NCAC 02T .0504(j) and 15A NCAC 02T .0508; the Plan must include: A detailed explanation as to how the generated residuals (including trash, sediment and grit) will be collected, handled, processed, stored, treated, and disposed. An evaluation of the treatment facility’s residuals storage requirements based upon the maximum anticipated residuals production rate and ability to remove residuals. A permit for residuals utilization or a written commitment to the Applicant from a Permittee of a Department approved residuals disposal/utilization program that has adequate permitted capacity to accept the residuals or has submitted a residuals/utilization program application. If oil, grease, grit or screenings removal and collection is a designated unit process, a detailed explanation as to how the oil/grease will be collected, handled, processed, stored and disposed. Not Applicable. APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC-12-14) Application for Authorization to Construct Permit (FORM ATC-12-14) Page 6 State of North Carolina Department of Environmental Quality Division of Water Resources SECTION 4: PROJECT INFORMATION A. WASTEWATER TREATMENT PLANT FLOW INFORMATION – COMPLETE FOR NEW OR EXPANDING FACILITIES 1. Provide the following flow information: n/a; facility is not new or expanding Plant Flows Existing Plant Design MGD Current NPDES Permit Limit MGD Current Annual Average (past 12 months) MGD For Past 12 Months: Start Date: month/yr End Date: month/yr For Past 24 Months: Start Date: month/yr End Date: month/yr Maximum Month MGD MGD Maximum Day MGD MGD Peak Hour MGD MGD APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC-12-14) Application for Authorization to Construct Permit (FORM ATC-12-14) Page 7 State of North Carolina Department of Environmental Quality Division of Water Resources B. WASTEWATER TREATMENT FACILITY DESIGN INFORMATION – COMPLETE FOR NEW OR EXPANDING FACILITIES AND FOR TREATMENT PROCESS MODIFICATIONS 1. Have all of the requirements of 15 NCAC 02H. 0100, 15A NCAC 02T, North Carolina General Statute 133-3, North Carolina General Statute 143-215.1, and Division of Water Resources Minimum Design Criteria for NPDES Wastewater Treatment Facilities been met by the proposed design and specifications? Yes or No. If no, provide justification as to why the requirements are not met, consistent with 15A NCAC 02T .0105(n): ______________________________________________ 2. Provide the design influent and effluent characteristics that are used as the basis for the project design, and the NPDES permit limits for the following parameters: Parameter Influent Concentration - Current Annual Average (past 12 months) if Available Project Basis of Design NPDES Permit Limits (monthly average) Design Influent Concentration (Must be supported by Engineering Calculations [Section 3.H]) Design Influent Load (Must be supported by Engineering Calculations [Section 3.H]) Design Effluent Concentration and/or Load Ammonia Nitrogen (NH3-N) mg/L 23.1 mg/L 1,156 lb/day 9 mg/L Summer 9 mg/L Summer 21 mg/L Winter 21 mg/L Winter Biochemical Oxygen Demand (BOD5) 173 mg/L 220 mg/L 11,009 lb/day 30 mg/L Summer 30 mg/L Summer 30 mg/L Winter 30 mg/L Winter Fecal Coliform 200 per 100 mL 200 per 100 mL Nitrate + Nitrite Nitrogen (NO3-N + NO2-N) mg/L mg/L Total Kjeldahl Nitrogen mg/L Total Nitrogen mg/L mg/L lb/year lb/year Total Phosphorus mg/L mg/L lb/day mg/L mg/L lb/year lb/year Total Suspended Solids (TSS) 219 mg/L 260 mg/L 13,010 lb/day 30 mg/L 30 mg/L 3. Based on the “Project Basis of Design” parameters listed above, will the proposed design allow the treatment facility to meet the NPDES Permit Limits listed above? Yes or No. If no, describe how and why the Permit Limits will not be met: 4. Per 15A NCAC 02T .0505(j), by-pass and overflow lines are prohibited. Is this condition met by the design? Yes or No If no, describe the treatment units bypassed, why this is necessary, and where the bypass discharges: APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC-12-14) Application for Authorization to Construct Permit (FORM ATC-12-14) Page 8 State of North Carolina Department of Environmental Quality Division of Water Resources 5. Per 15A NCAC 02T .0505(k), multiple pumps shall be provided wherever pumps are used. Is this condition met by the design? Yes or No. If no, provide an explanation: 6. Per 15A NCAC 02T .0505(l), power reliability shall be provided consisting of automatically activated standby power supply onsite capable of powering all essential treatment units under design conditions, or dual power supply shall be provided per 15A NCAC 02H. 0124(2)(a). Is this condition met by the design? Yes or No. If no, provide (as an attachment to this Application) written approval from the Director that the facility:  Has a private water supply that automatically shuts off during power failures and does not contain elevated water storage tanks, and  Has sufficient storage capacity that no potential for overflow exists, and  Can tolerate septic wastewater due to prolonged detention. 7. Per 15A NCAC 02T .0505(o), a minimum of 30 days of residual storage shall be provided. Is this condition met by the design? Yes or No. If no, explain the alternative design criteria proposed for this project in accordance 15A NCAC 02T .105(n): 8. Per 15A NCAC 02T .0505(q), the public shall be prohibited from access to the wastewater treatment facilities. Explain how the design complies with this requirement: The plant is enclosed by the fence and gate. 9. Is the treatment facility located within the 100-year flood plain? Yes or No. If yes, describe how the facility is protected from the 100-year flood: All improvements are designed to limit topography and floodplain impacts as much as practical. Best management practices for erosion and sediment control will be utilized during construction. The reuse pump station is watertight and vented 2 foot above the 100-year flood elevation. No WWTP components will be built in the floodway. The aeration basin modifications will be performed in an existing structure. The only space available within the boundaries of the WWTP that will permit the construction of large circular secondary clarifiers is the location of the existing primary clarifiers. While every effort will be made during the design process to locate the new secondary clarifiers outside the 100-year floodplain, they must be sized to perform adequately and constructed in a location that does not disrupt the hydraulic profile of the WWTP. C. WASTEWATER TREATMENT UNIT AND MECHANICAL EQUIPMENT INFORMATION – COMPLETE FOR NEW OR EXPANDING FACILITIES AND FOR MODIFIED TREATMENT UNITS 1. PRELIMINARY AND PRIMARY TREATMENT (i.e., physical removal operations and flow equalization): Treatment Unit No. of Units Type Size per Unit Plan Sheet Reference Specification Reference Calculations Provided? (Yes or No) Manual Bar Screen MGD at peak hourly flow Mechanical Bar Screen 2 Perforated Plate 15 MGD at peak hourly flow MA Sheets 462153 Grit Removal 1 Vortex 15 MGD at peak hourly flow MA Sheets 462323 Flow Equalization -- gallons Primary Clarifier Circular ft diameter; ft side water depth Primary Clarifier Rectangular square feet; ft side water depth Other 3 Disc Filter 15 MGD with 2 units in operation MA Sheets 466141 2. SECONDARY TREATMENT (BIOLOGICAL REACTORS AND CLARIFIERS) (i.e., biological and chemical processes to remove organics and nutrients) APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC-12-14) Application for Authorization to Construct Permit (FORM ATC-12-14) Page 9 State of North Carolina Department of Environmental Quality Division of Water Resources Treatment Unit No. of Units Type Size per Unit Plan Sheet Reference Specification Reference Calculations Provided? (Yes or No) Aerobic Zones/ Tanks 4 615,000 gallons MB Sheets 465133 Anoxic Zones/ Tanks gallons Anaerobic Zones/Tanks gallons Sequencing Batch Reactor (SBR) -- gallons Membrane Bioreactor (MBR) -- gallons Secondary Clarifier 2 Circular 100 ft diameter; 15 ft side water depth MF Sheets 464321 Secondary Clarifier Rectangular square feet; ft side water depth Other 3. TERTIARY TREATMENT Treatment Unit No. of Units Type Size per Unit Plan Sheet Reference Specification Reference Calculations Provided? (Yes or No) Tertiary Clarifier Circular ft diameter; ft side water depth Tertiary Clarifier Rectangular square feet; ft side water depth Tertiary Filter square feet Tertiary Membrane Filtration square feet Post-Treatment Flow Equalization -- gallons Post-Aeration gallons Other 4. DISINFECTION Treatment Unit No. of Units Type Size per Unit Plan Sheet Reference Specification Reference Calculations Provided? (Yes or No) Ultraviolet Light (Parallel; in series) gal/day per bank at peak hourly flow; number of banks; number of lamps/bank Chlorination 2 liquid (Gas; tablet; liquid) 83,020 gallons of contact tank/unit MH and MG Sheets 434143, 463344,463366 Dechlorination 2 liquid (Gas; tablet; liquid) 1833.5 gallons of contact tank/unit MG Sheets 434143,463344 APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC-12-14) Application for Authorization to Construct Permit (FORM ATC-12-14) Page 10 State of North Carolina Department of Environmental Quality Division of Water Resources 5. RESIDUALS TREATMENT Treatment Unit No. of Units Type Size per Unit Plan Sheet Reference Specification Reference Calculations Provided? (Yes or No) Gravity Thickening Tank 2 Gravity 380 square feet; 10 ft side water depth; 616 square feet; 10 ft side water depth MI Sheets 467113 Mechanical Thickening/ Dewatering 1 Belt Filter Press 2000 dry lb/hour MJ Sheets 467621 Aerobic Digestion gallons Anaerobic Digestion gallons Composting dry lb/hour Drying dry lb/hour Other 6. PUMP SYSTEMS (include influent, intermediate, effluent, major recycles, waste sludge, thickened waste sludge and plant drain pumps) Location No. of Pumps Purpose Type Capacity of each pump Plan Sheet Reference Specification Reference GPM TDH Influent 4 Influent Submersible 3,472 37 MA 105 432500 Primary Sludge 2 Primary Sludge Submersible 225 41 MA 108 432500 WAS 2 Secondary Sludge Self-Priming, Solid- Handling 520 47 MF sheets 432300 Reuse 2 Effluent Reuse Submersible 750 144 MH-103 432500 Secondary Clarifiers 2 Scum Transfer Submersible Grinder 30 24 MF-106 432613 7. MIXERS Location No. of Mixers Purpose Type Power of each Mixer (HP) Plan Sheet Reference Specification Reference 8. BLOWERS APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC-12-14) Application for Authorization to Construct Permit (FORM ATC-12-14) Page 11 State of North Carolina Department of Environmental Quality Division of Water Resources Location No. of Blowers Purpose Type Capacity of each Blower (CFM) Plan Sheet Reference Specification Reference By aeration basins 4 Aeration Rotary Screw 2330 MC sheets 431251 9. ODOR CONTROL Location No. of Units Purpose Type Plan Sheet Reference Specification Reference D. SETBACKS – COMPLETE FOR NEW WASTEWATER TREATMENT STRUCTURES 1. The minimum distance for each setback parameter to the wastewater treatment/storage units per 15A NCAC 02T .0506(b) are as follows: Setback Parameter Minimum Distance Required from Nearest Treatment/Storage Unit Is Minimum Distance Requirement met by the Design? If “No”, identify Setback Waivers in Item D.2 Below Any habitable residence or place of assembly under separate ownership or not to be maintained as part of the project site 100 ft Yes No Any private or public water supply source 100 ft Yes No Surface waters (streams – intermittent and perennial, perennial waterbodies, and wetlands) 50 ft Yes No Any well with exception of monitoring wells 100 ft Yes No Any property line 50 ft Yes No 2. Have any setback waivers been obtained per 15A NCAC 02T .0506(d)? Yes or No. If yes, have these waivers been written, notarized and signed by all parties involved and recorded with the County Register of Deeds? Yes or No. If no, provide an explanation: ___________________ Water Resources ENVIRONMENTAL QUALITY State of North Carolina Department of Environmental Quality Division of Water Resources APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC-12-14) SECTION 5: APPLICATION CERTIFICATION BY PROFESSIONAL ENGINEER Professional Engineer's Certification per 15A NCAC 02T .0105: I, M. Keith Webb, attest that this application package for an Authorization to Construct (Typed Name of Professional Engineer) for the Wastewater Treatment Plant Improvements Phase I, (Facility and Project Name) was prepared under my direct supervisory control and to the best of my knowledge is accurate, complete and consistent with the information supplied in the engineering plans, specifications, calculations, and all other supporting documentation for this project. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with all applicable regulations and statutes, 15 NCAC 02H. 0100, 15A NCAC 02T, North Carolina General Statute 133-3, North Carolina General Statute 143-215.1, and Division of Water Resources Minimum Design Criteria for NPDES Wastewater Treatment Facilities, and this Authorization to Construct Permit Application, except as provided for and explained in Section 4.B.1 of this Application. I understand that the Division of Water Resources' issuance of the Authorization to Construct Permit may be based solely upon this Certification and that the Division may waive the technical review of the plans, specifications, calculations and other supporting documentation provided in this application package. I further understand that the application package may be subject to a future audit by the Division. Although certain portions of this submittal package may have been prepared, signed and sealed by other professionals licensed in North Carolina, inclusion of these materials under my signature and seal signifies that I have reviewed the materials and have determined that the materials are consistent with the project design. I understand that in accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal with written signature placed over or adjacent to the seal and dated: 1 800 : 4- 13 -2-1 Application for Authorization to Construct Permit (FORM ATC-12-14) Page 12 Water Resources ENVIRONMENTAL QUALITY State of North Carolina Department of Environmental Quality Division of Water Resources APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC-12-14) SECTION 6: APPLICATION CERTIFICATION BY APPLICANT Applicant's Certification per 15A NCAC 02T .0106(b): I, Rob Hites, Town Manager, attest that this application package for an Authorization to Construct (Typed Name of Signature Authority and Title) for the Wastewater Treatment Plant Improvements Phase L (Facility and Project Name) has been reviewed by me and is accurate and complete to the best of my knowledge. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. I further certify that in accordance with 15A NCAC 02T .0120(b), the Applicant or any affiliate has not been convicted of environmental crimes, has not abandoned a wastewater facility without proper closure, does not have an outstanding civil penalty where all appeals have been abandoned or exhausted, are compliant with any active compliance schedule, and does not have any overdue annual fees. I understand that the Division of Water Resources' issuance of the Authorization to Construct Permit may be based solely upon acceptance of the Licensed Professional Engineer's Certification contained in Section 5, and that the Division may waive the technical review of the plans, specifications, calculations and other supporting documentation provided in this application package. I further understand that the application package may be subject to a future audit. I understand that in accordance with General Statutes 143-215.6A and 143-215.6B any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,0000,, as well as civil penalties up to $25,000 peer violation. fi4 '/ �/ /C' / Date: �// / ' Signature: i � ��- t. � , =- THE COMPLETED APPLICATION AND SUPPORTING INFORMATION SHALL BE SUBMITTED TO: NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER RESOURCES/NPDES By U.S. Postal Service 1617 MAIL SERVICE CENTER RALEIGH, NORTH CAROLINA 27699-1617 By Courier/Special Delivery: 512 N. SALISBURY STREET, 9TH FLOOR RALEIGH, NORTH CAROLINA 27604 TELEPHONE NUMBER: (919) 707-3644 Application for Authorization to Construct Permit (FORM ATC-12-14) Page 13