HomeMy WebLinkAboutNC0001406_Inspection_20100519ri
NCDENR
North Carolina Department of Environment and Natural Resources
Division of Water Quality
Beverly Eaves Perdue Coleen H. Sullins Dee Freeman
Governor Director Secretary
May 19, 2010
Steve Ward
Director of Public Utilities
P. O. Box 1119
Lillington, NC 27546
SUBJECT: April 29, 2010 Compliance Evaluation Inspection
County of Harnett
Erwin WWTP #2
Permit No: NC0001406
Harnett County
Dear Mr. Ward:
Enclosed please find a copy of the Compliance Evaluation Inspection form from the inspection conducted on April
29, 2010. The Compliance Evaluation Inspection was conducted by Mark Brantley, Environmental Chemist, of
the Fayetteville Regional Office. The cooperation of Mr. Thomas Ray, Grade III ORC, was greatly appreciated.
The facility was found to be in Compliance with permit NC0001406. As a reminder, preservation of the Waters of
the State can only be achieved through consistent NPDES Permit compliance.
Comments
• Facility was not discharging at the time of the inspection.
• The February 2010 DMR and laboratory bench sheets were reviewed and appeared to be in order.
Please refer to the enclosed inspection report for additional observations and comments. If you or your staff have
any questions, please call me at 910-433-3327.
Sincerely,
Mark Brantley
Environmental Chemist
Surface Water Protection Section
Fayetteville Regional Office
cc: Thomas Patterson Ray, ORC
Cent al e
North Carolina Division of Water Quality/Aquifer Protection Section 225 Green St./ Suite 714 Fayetteville, NC 28301 Phone (910) 433-3300
FAX (910) 486-0707 Internet: h2o.enr.state.nc.us Customer Service 1-877-623-6748
NorthCarolina
Naturally
An Equal Opportunity/Affirmative Action Employer — 50% Recycled/10% Post Consumer Paper
United States Environmental Protection Agency
EPA Washington, D.C. 20460
Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection
1 INI 2 15131 NC0001406 111 121 10/04/29 117
Type Inspector Fac Type
181 CI 191sI 20I II
1 1 1 1 1 1 1 1 1 1 1 1 1 1 l 166
Remarks
211 1 1 1 1 1 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I
Inspection Work Days Facility Self -Monitoring Evaluation Rating . B1 QA Reserved
671 169 70 13 I 711 NI 721 NI 731 I 174 751
I I I I I I 180
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES permit Number)
Erwin WWTP #2
411 S 20th St
Erwin NC 28339
Entry Time/Date
11:30 AM 10/04/29
Permit Effective Date
07/10/01
Exit Time/Date
12:15 PM 10/04/29
Permit Expiration Date
11/09/30
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
///
Thomas Patterson Ray/ORC/910-893-2424/
Other Facility Data
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Charles L Fiero, //910-814-3074/
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Flow Measurement • Operations & Maintenance Records/Reports
Self -Monitoring Program Facility Site Review
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date
Mark Brantley FRO WQ//910-433-3300 Ext.727/
Molt- 6 s-- , G-10
Signature of Management Q A Reviewer y444110.6 Agency/Office/Phone and Fax Numbers Date I
Belinda S Henson ✓ FRO WQ//910-433-3300 Ext.726/ 5 -2 a `/ b
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page # 1
31
NPDES
NC0001406 I11 12
yr/mo/day
10/04/29
Inspection Type
117 18I C I
1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Facility was not discharging at the time of the inspection.
The February DMR and laboratory data were reviewed and appeared to be in order.
Page # 2
Permit: NC0001406 Owner - Facility: Erwin WWTP #2
Inspection Date: 04/29/2010 Inspection Type: Compliance Evaluation
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? ■ n n n
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge n n n •
Judge, and other that are applicable?
Comment:
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new application? n ❑ • El
Is the facility as described in the permit? • ❑ n n
# Are there any special conditions for the permit? n ❑ ■ n
Is access to the plant site restricted to the general public? • ❑ ❑ ❑
Is the inspector granted access to all areas for inspection? ■ n . n n
Comment:
Record Keeping Yes No NA NE
Are records kept and maintained as required by the permit? • ❑ ❑ ❑
Is all required information readily available, complete and current? ■ ❑ ❑ n
Are all records maintained for 3 years (lab. reg. required 5 years)? ■ n n ❑
Are analytical results consistent with data reported on DMRs? ■ ❑ n ❑
Is the chain -of -custody complete? • n ❑ n
Dates, times and location of sampling ■
Name of individual performing the sampling ■
Results of analysis and calibration ■
Dates of analysis ■
Name of person performing analyses ■
Transported COCs. ■
Are DMRs complete: do they include all permit parameters? ■ ❑ n ❑
Has the facility submitted its annual compliance report to users and DWQ? n n n •
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? n n ■ ❑
Is the ORC visitation log available and current? ■ ❑ n n
Is the ORC certified at grade equal to or higher than the facility classification? • n ❑ ❑
Is the backup operator certified at one grade less or greater than the facility classification? ■ n
Is a copy of the current NPDES permit available on site? • n n ❑
Page # 3
Permit: NC0001406 Owner - Facility: Erwin WWTP #2
Inspection Date: 04/29/2010 Inspection Type: Compliance Evaluation
Record Keeping
Facility has copy of previous year's Annual Report on file for review?
Comment:
Secondary Clarifier
Is the clarifier free of black and odorous wastewater?
Is the site free of excessive buildup of solids in center well of circular clarifier?
Are weirs level?
Is the site free of weir blockage?
Is the site free of evidence of short-circuiting?
Is scum removal adequate?
Is the site free of excessive floating sludge?
Is the drive unit operational?
Is the return rate acceptable (low turbulence)?
Is the overflow clear of excessive solids/pin floc?
Is the sludge blanket level acceptable? (Approximately'/ of the sidewall depth)
Comment:
Aeration Basins
Mode of operation
Type of aeration system
Is the basin free of dead spots?
Are surface aerators and mixers operational?
Are the diffusers operational?
Is the foam the proper color for the treatment process?
Does the foam cover less than 25% of the basin's surface?
Is the DO level acceptable?
Is the DO level acceptable?(1.0 to 3.0 mg/I)
Comment:
De -chlorination
Type of system ?
Is the feed ratio proportional to chlorine amount (1 to 1)?
Is storage appropriate for cylinders?
Yes No NA NE
Finn■
Yes No NA NE
■ Finn
■ Finn
■ Finn
■ Finn
■ Finn
■ Finn
■ Finn
■ Finn
■ Finn
■ Finn
■ Finn
Yes No NA NE
Ext. Air
Surface
■ Finn
■ Finn
Fin■n
■ Finn
■ Finn
■ Finn
■ Finn
Yes No NA NE
Liquid
■ Finn
■ Finn
Page # 4
9 # abed
00011
uuu■
000•
000•
uuu■
0•00
3N VN oN saA
000•
000•
000•
000•
000•
0•00
3N VN ON saA
000•
000•
000•
000•
000•
000•
3N VN ON saA
0•00
0•00
000•
3N VN ON saA
quewwo3
z(en!}e}ueseJdeJ ads(} 6ulidwes `iiouenbai;)1!wJad ay} Aq paqnbaJ se pewuoj ed 6ulidwes A}Rios} ay} si
6(snisiao seaJ6ep 0.g o} lenbe Jo uey} ssai }e }day{) e6eao}s aidwes Jo} }es ein}eJedwa} Jedoid sl #
6ueep 6uign} ails!
6pa}oalioo awnion iadoid si
6s}!un }uew}eaj} Ile moleq pa}oalioo eidwes si
aeuol}Jodad mog 6ulldwes a}isodwoo si
6ulidweg;uanl3
guawwoo
L}iwJad ay} o} 6uipJ000e pawwojad 6ulidwes si
6(snisiao saai6ep 0•9 o} ienba Jo uey} ssai }e }day{) a6eJo}s eidwes Jo} }es ein}ejedwa} Jedaid sl #
6ueaio align} ay} si
6pa}oalioo awnion Jedad si
,sweet}s apis anoge pa}oalioo eidwes si
6leuoi}JodaJd moi} 6ulldwes eusodwoo si #
6ulidweg;uanl;ul
4UGW WO3
,uogeuuolyo-ep o} Loud lenpisal auuolyo amyl si
6dnpiinq e6pnis Jo 'y}nnoJ6 jo Jegweyo }oe}uoo ay} si
olge}deooe ienp!seJ auuolyo Io lanai ay} si
(suielp uado/sNeei }o ear}) o}enbape ease }uawuie}uoo Nue} e6eJo}s mnq sl
6ieuoi}eJedo we sAs pea} dwnd si (e uolyoodI(H wnlpos)
}ue}oe4ulsip }o AIddns eiueseJ a enbape amyl si
pinbl1-uol;oa;ulsla
:luewwOo
,asn ui sagn} jo JagwnN
i,leuoi}eJedo sJo}euuolyo-ep }alga} any
odAl pue ezis Jadad ay} s}aige} ay} eN
quawwoQ
,sieuie}uoo auuolyo woJ} /came paJo}s eoue}sgns uol}euuolyo-ep si #
uol;eulaol43-ea
uoi;enien3 eoueildwoo :edi(1 uo!1oadsul 06OZ/6Z/170 :oleo uoi;oadsul
Z# d1MM uiAu3 :/ il!3ed - JeumO 90176000ON :31wiad
Permit: NC0001406 Owner - Facility: Erwin WWTP #2
Inspection Date: 04/29/2010 Inspection Type: Compliance Evaluation
Flow Measurement - Effluent
# Is flow meter used for reporting?
Is flow meter calibrated annually?
Is the flow meter operational?
(If units are separated) Does the chart recorder match the flow meter?
Comment:
Yes No NA NE
■ nnn
■ nnn
■ nnn
nnn■
Page # 6