HomeMy WebLinkAboutWQ0036220_Regional Office Historical File Pre 2018NCDENR
North Carolina Department of Environment and Natural Resources
Beverly Eaves Perdue
Governor
Division of Water Quality
Charles Wakild, P. E Dee Freeman
Director Secretary
November 7, 2012
City of Kannapolis
Mr. Wilmer Melton, III -Director of Public Works
1401 Bethpage Road
Kannapolis, North Carolina 28081
Subject: Permit No.WQ0036220
Afton Ridge Apartments
Wastewater Collection. System Extension
Cabarrus, North Carolina
Dear Mr, Melton,
In accordance with your application received on October 31, 201.2, we are .forwarding herewith
Permit No.'WQ0036220, dated 'November '7, 2012, to the City of K.ann.apolis for the construction and
operation of the subject wastewater collection system extension. 'fins permit. shall he effective from the
date of issuance until rescinded, and shall be subject to the conditions and limitations as specific therein.
'This cover letter shall be considered a part of this permit and is therefhre incorporated therein by
refere.nce.
Please pay particular attention to Permit Condition 3 which requires that the wastewater
collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any
individual system -wide collection system permit issued to the Permittee.
:Permitting of this project does not constitute an acceptance of any part of the project that does
not meet I) 1 5A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum
Design Criteria adopted February, 12, 1996, as applicable; 3) and the Division's Minimum Design.
Criteria for the Fast-l'rack, Fern -lifting of Pump Stations and Force Mains adopted June 1, 2000, as
applicable, unless specifically ,mentioned herein, Division approval is based on acceptance of the
certification ,provided by a North Carolina -licensed Professional Engineer in the application. It shall be
the Permittee's responsibility- to ensure that the as -constructed project meets the appropriate design
criteria and rules. Failure to comply may result in, penalties in accordance with, North Carolina General
Statute §143-215,6A. through §143-215.6C, construction of additional or replacement wastewater
collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing
board..
One
aroluui
,Naturally
Mooresville Regional Office 610 East Center Ave., Suite 301 Moore- e., NC 28115 Phone: (704) 663-1699 Fax (704) 663-6040
Internet: www.ncrnwaterquality.org Customer Service_ 1-877-623(6748
An Equal Opportunity/Affirmative Action Employer — 50% Recycled/10% Past Consumer Paper
MMpIton
Page 2
November 7, 2012 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North
Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted
to Union County Public Works for the construction and operation of approximately 936 linear feet of 8-
inch gravity sewer, and the discharge of 34,560 gallons per day of col lected domestic wastewater into
Rocky River Regional Wastewater Treatrnent Plant, pursuant to the application received on October 31,
2012, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria
adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria tbr the Fast-',Frack
Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting
data subsequently filed and approved by the Department of Environment and Natural Resources and
considered a part of this permit.
Assessing subsequent impacts to the downstream collection system and treatment
facility is the complete responsibility of the Water and Sewer Authority of Cabarrus County
(WSACC). The (WSACC) must utilize whatever tracking tools necessary for planning additions
of sewer flow in order to maintain compliance with the WWTP permitted limits and the
WQCS00009 permit requirements.
Assessing subsequent impacts to the downstream collection system and treatment
facility is the complete responsibility of the City of Kannapolis. The City of Kannapolis must
utilize whatever tracking tools necessary for planning additions of sewer flow in order to
maintain compliance with the WWTP permitted limits and the collection system permit
WQCS00327.
The sewage and wastewater collected by this system shall he treated in the Rocky River
Regional Wastewater Treatment Plant WWTP (NPDES No.NC0036269) prior to being discharged into
the receiving stream.
If any parts, requirements, or limitations contained in this permit are unacceptable, you have the
right to request an adjudicator y hearing upon written request within 30 days following receipt of this
permit. This request :must be in the form of a written petition, conforming to Chapter 150B of North
Carolina General Statutes, and tiled with the Office of Administrative Hearings, 6714 Mail Service
Center, Raleigh, NC 27699-6714, Unless such demands are made, this permit shall, he final and binding.
If you need additional information concerning this matter, please contact Saxnar Bou-Ghazale at
(704) 663-1699.
cc:
Mooresville Regional Office, Collection System .Permit File
Surface Water Protection Central Files
PERCS
NORTH CAROLINA
ENVIRONMENTAL MANAGEMENT COM JSSION
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
RALEIGH
WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT (MODIFICAT(ON)
This permit shall be effective from the date of issuance until rescinded and shall be subject to the
following specified conditions and limitations:
1. This permit shall become voidable unless the wastewater collection facilities are constructed in
accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's
(Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the
Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force
Mains adopted June 1, 2000, as applicable: and other supporting materials unless specifically
mentioned herein,
2. This permit shall be effective only with respect to the nature and volume of wastes described in the
application and other supporting data.
3, The wastewater collection facilities shall be properly maintained and operated at all times. The
Permittee shall maintain compliance with an individual system -wide collection system permit for the
operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual
permit is not required, the following performance criteria shall be met as provided in 15A NCAC 27
.0403:
a. The sewer system shall be effectively maintained and operated at all times to prevent
discharge to land or surface waters, and any contravention of the groundwater standards in
15A NCAC 2L ,0200 or the surface water standards in 15A NCAC 26 .0200.
b. A map of the sewer system shall be developed and shall be actively maintained.
c. An operation and maintenance plan shall be developed and implemented
d. Pump stations that are not connected to a telemetry system shall be inspected every day (Le.
365 days per year). Pump stations that are connected to a telemetry system shall be
inspected at least once per week.
e. High -priority sewer lines shall be inspected at least once per every six-month period of time.
f. A general observation of the entire sewer system shall be conducted at least once per year.
g. Inspection and maintenance records shall be maintained for a period of at least three years.
h. Overflows and bypasses shall be reported to the appropriate Division regional office in
accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by
North Carolina General Statute §143-215.1C.
4. rhis permit shaft not be transferable. In the event -There is Tdesire for the WaStewater collectidn
facilities to change ownership, or there is a name change of the Permittee, a formal permit request
shall be submitted to the Division accompanied by documentation from the parties involved, and
other supporting materials as may be appropriate. The approval of this request shall be
considered on its merits and may or may not be approved.
5, Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to
interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater
to the surface waters of the State.
Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these
permitted facilities, the completed Engineering Certification form attached to this permit shall be
submitted with the required supporting documents to the address provided on the form. A complete
certification is one where the form is fully executed and the supporting documents are provided as
applicable,
7 A copy of the construction record drawings shall be maintained on file by the Permittee for the life
of the wastewater collection facilities.
Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the
Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's
Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted
June 1, 2000 as applicable, and other supporting materials may subject the Permittee to an
enforcement action by the Division, in accordance with North Carolina General Statutes §143-
215.6A through §143-215,6C
In the event that the wastewater collection facilities fail to perform satisfactorily, including the
creation of nuisance conditions, the Permittee shall take immediate corrective action, including
those as may be required by this Division, such as the construction of additional or replacement
facilities,
10. The issuance of this permit shall not exempt the Permittee from complying with any and all
statutes, rules, regulations, or ordinances that may be imposed by other government agencies
(local, state and federal) which have jurisdiction, including but not limited to applicable river buffer
rules in 15A NCAC 2B ,0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4
and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands
under 15A NCAC 2B ,0200 and 15A NCAC 211 0500.
11 Noncompliance Notification:
The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville
Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than
24 hours or on the next working day, following the occurrence or first knowledge of the occurrence
of either of the following:
a Any process unit failure, due to known or unknown reasons, that renders the facility incapable
of adequate wastewater transport, such as mechanical or electrical failures of pumps, line
blockage or breakage, etc., or
b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters
without treatment of all or any portion of the influent to such station or facility.
Voice mail messages or faxed information is permissible, but shall not be considered as the
initial verbal report. Overflows and spills occurring outside normal business' hours may also be
reported to the Division of Emergency Management at telephone number (800) 858-0368 or
(919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by
completing Part I of Form CS-SSO (or the most current Division approved form), within five days
following first knowledge of the occurrence. This report shall outline the actions taken or
proposed to ensure that the problem does not recur, Part II of Form CS-SSO (or the most
current Division approved form) can also be completed to show that the SSO was beyond
control,
Permit issued this the 7Th day of November, 2012.
NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION
for Charles Wakild„ RE., Dire
Division of Water Quality
By Authority of the Environmental Management Commission
Permit Nurnher WQ003622()
tor
Fast Track Engineering Certification
Permit No W90036226
November 7, 2012
City of Kannapolis
Wilmer Melton, Ill
401 Bethpage Road
Kannapolis, NC 28081
Paul Campbell, PE
NorthEast Engineering, PA
41 Edgewood Ave, NE
Concord, NC 28128
Complete and submit this form to the permit issuing regional office with the following:
• One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection
system extension
• Supporting design calculations (selected pumps, system curve, operating point, available storage if poi/able
generator(s) or storage greater than longest past three year outage reliability option selected) for any pump
stations permitted as part of this project
• Changes to the project should be clearly identified on the record drawings or in written summary form Permit
modifications are required for any changes resulting in non-compliance with this permit, regulations or
minimum design criteria.
This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all
required supporting documentation have been received by the Division. Therefore, it is highly recommended
that this certification be sent in a manner that provides proof of receipt by the Division,
ENGINEER'S CERTIFICATION
Li Partial L] Final
, as a duly registered Professional Engineer in the State of North Carolina, having been
authorized to observe (El periodically, [11 weekly, full time) the construction of Afton Ridge Apartments, a
Cabarrus County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was
used in the observation of the construction such that the construction was observed to be built within substantial
compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design
Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track
Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials.
North Carolina Professional Engineer's
seal, signature, and date:
SEND THIS FORM & SUPPORTING DOCUMENTATION
WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS
MOORESVILLE REGIONAL OFFICE
SURFACE WATER PROTECTION
610 EAST CENTER AVENUE, SUITE 301
MOORESVILLE NC 28115
The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any
wastewater flow made tributary to the wastewater collection system extension prior to completion of this
Engineers Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate
enforcement actions.
!IFIFilir-
- USE THE TAB KEY TO MOVE FROM FIELD TO FIELD!
1 Owner/Permittee:
la. Ctly_of Kannapolis
Full Legal Name (company, municipality, HOA, utility etc.)
Application Number
(to be completed by DWQ) \x!
0 WilmerMelton, Director of Public Works
Signing Official Name and Title (Please review 15A NCAC 2T 0106 (b) for authorized signing officials!)
< lc. The legal entity who will own this system is:
Li individual Federal Municipality 1] State/County [12, Private Partnership [1] Corporation El] Other (specify):
C4
0 ld. 1401 Beth_page Rd Kannapolis
L.L. Mailing Address City
Z
ft NC lg. 28081
Z State Zip Code
1 0in 704-920-4200 _ .„ 1i, 1j. wrneltontkicityofkanaiapoliticom_
Telephone Facsimile
a.
a.
0
ce
0
LL
th
E-mail
2. Project (Facility) Information:
2a. Afton Rie Aprtrnents 2b Cabarrus
Brief Project Name (permit will refer to this name)
ContactPerson:
3a. Paul Campbell, desigp Engineer
Name and Affiliation of Someone Who Can Answer Questions About Application
31). 704-788-6372 3c. pcampbell@nee-pacorn
Phone Number E-mail
Project js New [I] Modification (of an existing permit) If Modification,. Permit No,:
2, Owner is Ni Public (skip to Item B(3))
2a. If private, applicant will be
County Where Project is Located
Ell Private (go to Item 2(a))
2bif sold, facilities owned by a (must choose one)
Retaining Ownership (i.e. store, church, single office, etc.) or
L] Leasing units, (lots, townhomes, etc„ - skip to Item B(3))
[Ij Selling units (lots, townhornes, etc. - go to Item B(2b))
3 Water & Sewer Authority of Cabarrus County
Owner of Wastewater 'Treatment Facility (WWTF) Treating Wastewater From This Project
4.a. Rocky River Reonal Wastewater Treatment Plant 4b. NC.0'0036269
Name of WWTF WWTF Permit No.
rl Public Utility (Instruction Cl
Ej Homeowner Assoc./Developcir (Instruction D)
5aCity, of Kannapolis 5bGravity
Owner of Downstream Sewer !FReceiving Sewer Size Force Main 15°'
. 1„ _ iZ
6. The origin of this wastewater is (check all that app(y):
ri Residential Subdivision
LLiLi Apartments/Condominiums
[1 Mobile Home Park
0 School
LI Restaurant
Ei Office
Permit # of Downstream Sewer (Instruction Fi)
LJ Retail (Stores, shopping centers)
LIILiinstitution
LI Hospital
1111 Church
LI Nursing Home
El) Other (specify)
7 Volume of wastewater to be allocated or permitted for this particular project:34560
*Do not include future flows or previously permitted allocations
8. If the permitted flow is zero, indicate why,
'A Domestic/Commercial
c/0 Industrial (attach
description:
(RO: contact your Regional Office
Pretreatment staff)
% Other (specify):
_ gallons per day
0 Pump Station, Outfall or Interceptor Line where flow wilt be permitted in subsequent permits that connect 'Jts
E Flow has already been allocated in Permit No,
Er Rehabilitation or replacement of existing sewer with no ne
permit is required)
w expected (see 15A NCAC 02/1,0303 to deterrone LI a
FliA I 21E7
!PIIIFFP'
. ..
9 Provide the wastewater flow calculations used in determining the permitted flow n accordance with 15A NCAC 21 .0114 for
the value in item B(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in
Item B(7), Values, other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or yvaslewater us()
data in accordance with 15A NCAC 2T „0114 (f).
360 gpd per apartment at 96, apartments or 34,560 gpd
10. Summary of Sewer Lines to be Permitted (
h addit oie sheets if necessary)
Size (inches) Length (feet)
8935 64
New Gravity or Additional
Force Main
New gravity
Summary of Pump Stations wl associated Force Mains to be Permitted (attach additional sheets as necessary)
DI Pump Station Location ID (self chosen - as shown on plans/map for reference)
z
1-- Design Flow
Operational Point 1 - Power Reliability Option
Z (MGD)
GPM @TDH permanent generator MATS; Force Main Size Force Main Length
0 2 - portable generator wfMTS
0
0
1— Pump Station Location ID (self chosen as shown on plans/map for reference)
itt
5 Design Flow Power Reliability Option
(MGD} Operational Point GPM @TDH 1 permanent generator w/ATS; Force Main Size Force Main Length
O 2 - portable generator w/MTS
Lt.
z
Et Pump Station Location D (self chosen - as shown on plans/map for e e once)
LLi
Cl. Design Flow
Operational Point Power Reliability Option
(MGD) ai GPM @TDH 1 - permanent generator MATS; Force Main Size Force Main Length
2 - portable generator w/MTS
12 vi the wastewater flowin the proposed sewer lines or pump stations be able to be directed to another treatment facility'?
El Yes N No If Yes, permit number of 2rrd treatment facility
(Ro if "yes' to B,12 please contact the Central Office PERCS Unit)
13. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of F-kirrip Stations and irerce
Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 21 as
applicable?
Ni Yes 1 No If No, please reference the pertinent minimum design criteria or regulation and indicate why a
variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS
PERTINENT TO THE VARIANCE WITH YOUR APPLICATION
2/07
!IIPIFFPA Hayeithe following .permitstertifications been submitted for approval for the system or project to be served?
Wetland/Stream Crossings - General Permit or 401Certificat0 ion? Yes No Z NIA
Sedimentation and Erosion Control Plan? Z Yes 0 No D NiA
Stormwater? Z Yes 0 No D N/A
15, Does this projectinclude any high priority lines, [see 15A NCAC 02T _0402 (2)) involve aerial lines, siphons or interferonce
manholes)? These lines will be considered high priority and must be checked once every six months
(7,hieek. if Yes: E and provide details
1. OwnerlPermittee's Certification: (Signature of Signing Official and Project Name)
l, Wilmer Me/terL lit, Director of Public Works, attest that this application for
has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all require()
parts of this application are not completed ,and that if all required supporting documentation and attachments' het
included, this application package is subject to being returned as incomplete, Note: In accordance with Nord Carolina
General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement ropreseritaticro,
certification in any application shall he guilty of a Class 2 misdemeanor which may Include a fine not to exceed $10,000
as well as civil penalties up to $25:000 per violation,.
1a. ?
Signing Gftcial Signature Date
ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS
APPLICATION, THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIWTY
w TO OTHER UTILITIES, DESIGN CALCULATIONS ETC REFER TO 15A NCAC 02T .0305
0
F7- 2. Professional Engineer's Certification: (Signature of Design Engineer and Project Name)
d
Panl D, Campbell , attest that this application for Afton Ridge Apartments has beer reviewed
by me and is accurate, complete and consistent with the information in the engineering plans; COICEllatfbnS. and off other
supporting documentation to the hest of my knowledge. further attest that to the best of my ,know/edge Inc proposed
design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Crifero for
Gravity Sewers adopted February 121996, and the Minimum Design Criteria for the .Fast -Track Permitting of Pump
Stations and Force Mains adopted June 'I, 2000 and the watershed classification in accordance ,v'ith Divtsion gudance.
Although other professionals may have developed certain portions of this submittal package, inclusion of those t77atorwis
under my signature and seal signifies that I have reviewed this material and have judged it to be consistent the
proposed design: Note: In accordance ,,,vith NC General Statutes 143-215,6A and 143-215.6B, any person who knowmgry
makes any false statement, representation, or certification in any application shall be guilty of Class 2 misdomeanor
which may include a fine not to exceed $10, 000 as well as civil penalties up to .$2.5,000 per violation.
2a. Paul D. Campbell, PE
Professional Engineer Name ri
2b NorthEast Enaireeriftg, PA S,si •
Engineering Firm
2c. 41 Ectgewocd Ave, NE
Mailing Address
2d Concord, 2e, NC 2f, 28128
City State. Zip
2g. 704-788-.6.372 2h. 704-786-4756 2i. pcampbelignee:pa.born
Telephone Facsimile E-mail
\\\\lVdI Itiqh,//
WATER & SEWER AUTHORITY
OF CABARRUS COUNTY
Mr. Ntic.hael Legg
City Manager
City of Kannapol is
P.O. Box 1.199
Karmapolis, NC 28082-1199
Su
ect:
Dear Mr. Legg:
October 23, 2012
Flow Acceptance .Request City of Kannapolis
Afton Ridge Apartments
(Ake: 232 Davidson Hwy„
Corimmi,. NC 280)7'
Mail to: F.J. Box 428
C.,,i-icord, NC 28026-0428
Phone: 704.786„1783
Fax: 704,795.1564
This is an approval of flow acceptance that was received by the Water and Sewer Authority of Cabarrus
County (WSACC) for the City of Kannapolis on October 22, 2012. WSACC has or will have capacity at
the Rocky River Regional Wastewater Treatment Plant and appropriate sewer interceptors to transport
and treat the domestic wastewater from the proposed .Afton Ridge .Apartments project located along Glen
.Afton Boulevard southwest of the intersection with .Kannapolis Parkway', The referenced project includes
96 multi -family residential (3-bedroom) units with a projected wastewater flow of 34,560 gpd.
The wastewater generated by this project' N:vi 1 1. be conveyed. through. the City of Kannapolis' proposed and
existing gravity system., and then enter WSACC's system at the existing 27-inch Coddle Creek
Interceptor located south of the proposed. project. WSACC agrees to accept wastewater from the
proposed residential development based on information provided by Northeast .Engineering, .R.A. (Civil
Engineer for the project) using North Carolina Department of Environment and 'Natural Resources
(NCDENR) wastewater flow guidelines. 'the projected flow is 34,560 gpd; however 'WSACC expects die
actual wastewater flow to more closely approximate. 27,650 gpd. based upon Master Plan engineering
data.
The WSACC Capital Improvement .Program (CIP) has been on pa as you go since Fiscal Year 2005 —
2006 and has funded Capital Projects entirely from Capital Reserves, and expects to continue this policy
into the future. Projects on the CIP are subject to approval by WSACC' s Board of Directors, support
from local governing bodies, regulatory approval, and funding availability, At this time there are no
scheduled upgrades to WSACC facilities in. the current six year CIP that are located. downstream of this
proposed project, It should be noted that the list and schedule of CIP projects are tentative and are
revised periodically to reflect changing conditions and needs.
.If you have any questions, please call me at (704) 7.86-1783, extension 228.
a r
'Thomas A. Bach, RE.
Utility Systems Engineer
cc: Steve Bissinger, R.E./Kannapolis
Wilmer Melton/Karmapolis
Paul Campbell, PE/Northeast Engineering, P.A.
Coleman Keeter/WSACC
(.://had 'VonCannon, P,E./WSACC
Mark Loin axikk"S.A.CC
State of North Carolina
Department of Environment and Natural Resources
Division of Water Quality
Flow Tracking/Acceptance for Sewer Extension Permit Applications
( ['TS E — I 0/07 )
(WSACC USE ONLY) Afton Ridge Apartments Project
lon I. Name of wastewater treatment facility (WWTF) receiving' wastewater:
Rocky River Wastewater Treatment Facility ---- Permit No: NC0036269
Muddy Creek Wastewater Treatment Facility --- Permit No: NC0081621
\V\VIt' facility's permitted tlow, MGD
Estimated obligated flow not yet tributary to (he WWTP, MGD
WWTP facility's actual aysdaily flow, MGD
Total flow for this specific request, MGD
actual and obligated flows to the facility, MGD
Percent of permitted flow used
26.500
0.869
of_permiti
1035
15.524
58.58%
Section IL Pump stations along the route from the Jurisdiction's connection point to the WWTP.
(Fur eachexisting pump station to be impacted by this proposed sewer extension project, list each pump
station name, approximate pump station firm (design) capacity and approximate current average flow
(previous -12 months) for each pump station. Include the proposed flow for this project and other flows that
have been approved for the pump station but are not yet tributary.)
Pump Station Name:
'II Main PS
Approx. Capacity, MCiD Approx. Current Avg.
Wirt:II/Design) Daily How, MGD
554,10 9,810
Section 1111. WSACC Certification Sta
1. Thomas A. Bach.
certify that, to the best of my knowledge, the addition of thL
volume of 'wastewater to be permitted in this project has been evaluated along the route from the
connection to the interceptor to the receiving wastewater treatment facility and that the flow from this
project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any
clownstream pump station en route to the receiving treatment plant. This analysis has been preformed in
accordance with local established policies and procedures using the best available data, This certification
applies to those items listed above in Section I: and Section ff for which, to the best of my knowledge, will
not adversely affect the downstream sewer capacity. Signature of this form indicates acceptance of this
eater flow,
VI/SACC's Signing ( 'clot Signature
R evi n Dare: 02103/0-4
KANNAPOI
October 29, 201' 12501-18
NC Div of Environmental Management.
Department of Environment and Natural Reso urces Di ion of Water Quality
610 East Center Drive, Suite 301
Mooresville, North Carolina 28115
Re: Alton Ridge Apartments
Sewer Extension
City of Kannapolis - Cabarrus County
Dear Sir or Madam:
Please Lind attached for your review and approval thcc original and one copy of the permit
application and a cheek for 5480.00 for the processing fee for the above reference project. Also
enclosed is the flow acceptance letter from the Water & Sewer Authority of Cabarrus County
stating they will accept and treat the additional wastewater at the Rocky River Regional
Wastewater 'Treatment Plant.
The Water and Sewer Authority of Cabarrus County Standard Specifications for Wastewater
Collections Systems were approved by your office and are being maintained by the Division of
Envu'onlnental Management, This project will be installed in accordance with these Standard
Specifications.
Please call nee at 704-938-1519 if you have any questions.
Sincerely,
Steppe J. E Tssinger, PE
Assistant City Engineer
12501-1 B Afton Ridge Apartments Sewer Permit
C 1 "i
0
ette
F K ANNA
0 1. i S
Engineer
P.O. Box 1248 t annap li v'C SC1 2-1248 120 S. Main St Kannapolis, NC 28081
T 704.938.1519 F 704 938.681w0
Permit Numbti WQ003622O
Central Files: AP'S SWP
11/07/12
— --rWrrnit Tracking -Sap
Program Category
Non -discharge
Permit Type Fast Trail,
Gravity Sewer Extension, Pump Stations, & Pressure Sewer
Extensions
Primary Reviewer
samar, bou-ghazale
Coastal SW Rule
Permitted Flow
34560
Facility
Facility Name
Afton Ridge Apartments
Location Address
Owner
Status
Active
Version
1,00
Project Type
New Project
Permit Classification
Individual
Permit Contact Affiliation
Major/Minor
Minor
Region
Mooresville
County
Cabarrus
Facility Contact Affiliation
Owner Name
City of Kannap I
Dates/Events
Orig Issue
11/07/12
App Received
10/31/12
Regulated Activities
Apartment complex
Condominium
Wastewater collection
Outfall NULL
Draft initiated
Scheduled
issuance
Owner Type
Government - Municipal
Owner Affiliation
Wilmer Melton III
DIR PUBLIC WORKS
1401 Bethpage Rd
Kannapolis NC
Public Notice Issue Effective
11/07/12 11/07/12
Requested/Received Events
Additional information requested
Additional information received
28081
Expiration
Waterbody Name
Stream Index Number Current Class Subbasin
6f 4560,531
2061
ACBC LLC.
336.629.5164
F'»D, BOX 280
ASHHEBORO, NC 27204
DAY 70THE
ORDER Of
T DANK
m«„w
Fast Track Engineering Certification
Permit No, W00036220
November 7, 2012
City of Kannapotis
Wilmer Melton, Ii
401 Bethpage Road
Kannapalis, NC 28081
Paul Campbell, PE
NorthBast Engineering, PA
41 Edgewood Ave, NE
Concord, NC 28128
Complete and submit this form to the permit issuing regional office with the following:
• One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection
system extension
• Supporting design calculations (selected pumps, system curve, operating point, available storage if portable
generator(s) or storage greater than longest past three year outage reliability option selected) for any pump
stations permitted as part of this project
Changes to the project should be clearly identified on the record drawings or in written summary form. Permit
modifications are required for any changes resulting in non-compliance with this permit, regulations or
minimum design criteria.
This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all
required supporting documentation have been received by the Division. Therefore, it is highly recommended
that this certification be sent In a manner that provides proof of receipt by the Division,
ENGINEER'S CERTIFICATION
El Partial
Final
\, as a duly registered Professional Engineer in the State of North Carolina, having been
authorized to observe 'odically, E] weekly, L full time) the construction of Afton Ridge Apartments, a
Cabarrus County projectprojectfor the Permittee, hereby state that, to the best of my abilities, due care and diligence was
used in the observation of the construction such that the construction was observed to be built within substantial
compliance of this permit, 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design
Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track
Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials,
North Carolina Professional Engineer's
seal, signature, and date:
SEND THIS FORM & SUPPORTING DOCUMENTATION
WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS
MOORESVILLE REGIONAL OFFICE
SURFACE WATER PROTECTION
610 EAST CENTER AVENUE, SUITE 301
MOORESVILLE NC 28115
The Permittee is responsible for tracking all partial certifications up until a final certification is received, Any
wastewater flow made tributary to the wastewater collection system extension prior to completion of this
Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate
enforcement actions.