Loading...
HomeMy WebLinkAboutWQ0042462_Application (FTSE)_20210420BOHLER ENGINEERING NC, PLLC 1927 South Tryon Street Suite 310, Charlotte, NC 28203 Professional Engineering Services Telephone: (980)272-3400 Fax: (980)272-3401 LETTER OF TRANSMITTAL VIA: FedEx TO: NC DEQ RE: Private Sewer Main Extension NCDEQ Permit Water Resources 610 East Center Avenue, Suite 301 Everbrook Academy Huntersville Mooresville, NC 28115 RECEIVED/NCDEQ/DWR ATTN: Ori Tuvia/Barry Love DATE: April 19, 2021 JOB NO: NCC182115 APR 2 0 2021 WOROS MOORESVILLE REGIONAL OFFICE WE ARE SENDING YOU ❑ Shop drawings ❑ Copy of letter ®Attached ❑ Prints ❑ Change order These Are Transmitted: REMARKS: COPIES DESCRIPTION 1 Utility Plans 1 USGS Map 1 Fee ($480) 1 FTA 1 FTSE/Willingness to serve 1 Cover Letter ❑ For approval ® For review and comment ❑ Returned for corrections For your use As requested ❑Approved as submitted Approved as noted If you have any questions or require additional information, please do not hesitate to contact this office at (980) 272-3400. COPY TO: SIGNED: Michael Theberge, P.E. Project Manager Project: Fast Track Sewer Extension Cover Letter 12918 Eastfield Road — Eastfield Daycare Huntersville PID: 02708402 Charlotte Mecklenburg, NC Project #: NCC182115 Date: April 19th, 2021 As part of the Fast Track Sewer Application (specific to all private sewer main onsite) for the Eastfield Daycare Huntersville project, it is required that a Cover Letter accompany the application. This project will include the construction of (1) Daycare facility on (1) constructed private street and (1) private drive aisle within Mecklenburg County, NC, as well as associated utilities, drainage, and landscaping. The proposed sanitary sewer system will tie-in to an existing sanitary sewer system to both the south and north of the project site. The required flow allocation for this project is 4,475 GPD. This package includes the information listed below in order to permit the project described above for a private sewer main extension. • Cover letter RotaI Acccp er, / cTs • Sewer FTA Application , • Application Fee ($480) • USGS Topo Ma • Flow Tracking Form Please feel free to contact this office at 980-272-3400 if you have any questions or need further clarifications. Professional Engineer: Michael A. Theberge Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION FIR1Flu n/NCDEQ/DWR Application Number: o be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: APR 2 0 2021 WQROS MOORESVILLE REGIONAL OFFICE 1. Applicant's name: Ambrosino Consultant Corporation (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual 1 Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ❑ Municipal 3. Signature authority's name: Michael Ambrosino per I5A NCAC 02T .0106(b) Title: President 4. Applicant's mailing address: 155 15t Street City: Mineola State: NY Zip: 11501- 5. Applicant's contact information: Phone number: (516) 644-2222 Email Address: mambrosinoAambrosinocorp.com ❑ Other II. PROJECT INFORMATION: 1. Project name: Eastfield Daycare Huntersville 2. Application/Project status: Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00 and issued date: If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Mecklenburg 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.374939° Longitude: -80.8024° 5. Parcel ID (if applicable): 02708402 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Michael Theberge License Number: 043610 Firm: Bohler Engineering Mailing address: 1927 South Tryon St. Suite 310 City: Charlotte State: NC Zip: 28203- Phone number: (980) 272-3400 Email Address: mtheberge(abohlereng.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Rocky River WWTF Permit Number: NC0036269 Owner Name: WSACC V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ Downstream (Receiving) Sewer Size: inch System Wide Collection System Permit Number(s) (if applicable): WQCS Owner Name(s): FORM: FTA 04-16 Page 1 of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? El Yes ❑No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑No ®N/A 3. If the Applicant is a Home/Property Owners' Association, has an Operational Agreement (FORM: HOA) been attached? ❑ Yes ❑No ZN/A 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Residential Leased ® School / preschool / day care ❑ Food and drink facilities ❑ Businesses / offices / factories ❑ Retail (stores, centers, malls) ❑ Retail with food preparation/service ❑ Medical / dental / veterinary facilities ❑ Church ❑ Nursing Home 5. Nature of wastewater : % Domestic/Commercial 100 % Commercial % Industrial (See 15A NCAC 02T .0103(20)) ❑ Car Wash ❑ Hotel and/or Motels ❑ Swimming Pool /Clubhouse ❑ Swimming Pool/Filter Backwash ❑ Other (Explain in Attachment) >Is there a Pretreatment Program in effect? ❑ Yes 6. Has a flow reduction been approved under 15A NCAC 02T .0114(f}? ❑ Yes ® No ➢ If yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: ❑ No Establishment Type (see 02T.0114(f)) Daily Design Flow a,b No. of Units Flow Daycare 25 gal/person 179 4475 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 4475 GPD a See 15A NCAC 02T .01 14(b), (d), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01 14] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 4475 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & DC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 130 PVC ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: . Longitude: - ° 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at 5. Summarize the force main to be permitted (for this Pump Station): feet total dynamic head (TDH) Size (inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B): ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(1)): 1. Does the project comply with all separations found in 15A NCAC 02T .0305(f) & (g) ➢ 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: ❑ Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage ➢ If noncompliance with 02T.0305(f) or (g), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ❑ Yes ❑ No ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected / 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No Ai N/A ➢ This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer Permitting Branch ❑ Yes 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ❑ Yes Q No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermi s or deteriorates the sewer. ❑ Yes ❑ No NIA ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with I5A NCAC 02T, the Minimum Design Criteria for the Pertnittina of Purnp Stations and Force Mains (latest version). and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: I, i�h/e/ r0,e (Professional Engineer's name fr Application Item III.1.) attest that this application for has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T .0106(b): �O (Signature Authority's name & title from Application Item 1.3.) attest that this application for has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not o exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: FORM: FTA 04-16 Page 5 of 5 CHARLOTTE January 26, 2021 Mr. Tom Crouch Full Moon of Union, LLC 231 Post Office Drive Suite B-8 Indian Trail, NC 28079 SUBJECT: WATER AND SEWER FLOW ACCEPTANCE EASTFIELD AND PROSPERITY DAYCARE AND RETAIL 12918 EASTFIELD ROAD, CHARLOTTE, NC 28078 CLTWATER TRACKING # 202134 After analysis of the sanitary sewer associated with the proposed design of project 202134, EASTFIELD AND PROSPERITY DAYCARE AND RETAIL, it was determined that there is sufficient capacity to accommodate the proposed sewer flow of 4,475 gallons per day (Daycare, 179 persons x 25 gpd/person) at the connection point(s) indicated on the submitted utility plan for transmission to the Rocky River Wastewater Treatment Plant; NPDES permit number NC0036269, located in Cabarrus County, for treatment. This acceptance of flow is based on the existing capacity of the designated publicly owned treatments works. Please see the attached WASCC-FTSE form. CLTWater agrees to furnish water to the subject project. The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986 and The Water Supply Management Plan, PWS ID # 0160010 on file with the Public Water Supply Section of NCDEQ. However, CLTWater cannot guarantee a constant pressure or quality of flow. CLTWater does not expect any of the above conditions to preclude water or sewer service to the subject site. However, the applicant should understand that due to the involvement of other agencies and continuing growth of the water and sewer system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the CLTWater and sewer system is accepted on a first come, first served basis. The applicant should understand that this letter is not authorization to construct or extend private water or sewer systems, as the appropriate local or State permits are required prior to construction. If the appropriate authorization to construct permits are not obtained and construction has not started within two (2) years of issuance of this flow acceptance, and payment for any service connection(s) has not been received within two (2) years of issuance of this flow acceptance, this flow acceptance approval shall be rescinded, and a new flow acceptance request must be made. If you have any questions, please do not hesitate to contact me at (704) 432-5801. Sincerely, GU .rwvo- Awzota. Guillermo Anzola Engineering Assistant Charlotte Water 5100 Brookshire Blvcl, Charlotte, NC 28216 charlottewater.org Operated by the City of Charlotte ISO 14001;2015.11C Star Public Sector + OHSAS 18001:1001 March 1, 2021 Mr. Guillermo Anzola Engineering Assistant Charlotte Water 5100 Brookshire Blvd. Charlotte, NC 28216 Subject: Flow Acceptance Request Eastfield and Prosperity Daycare and Retail Charlotte Water Project Number 202134 Dear Mr. Anzola: WATER & SEWER AUTHORITY OF CABARRUS COUNTY 232 Davidson Hwy. Concord, NC 28027 704.786.1783 • 704.795.1564 Fax www.wsacc.org This is a notice of capacity for the flow acceptance request received by the Water and Sewer Authority of Cabarrus County (WSACC) from Charlotte Water on February 23, 2021. WSACC has or will have capacity at the Rocky River Regional Wastewater Treatment Plant and appropriate sewer interceptors to transport and treat the commercial wastewater from the proposed project entitled Eastfield and Prosperity Daycare and Retail. The referenced project will serve a commercial development with a 179-person daycare, with a projected wastewater flow of 4,475 gallons per day (gpd). The wastewater generated by this project will be conveyed through a proposed gravity system, through an existing gravity system, and then enter WSACC's system at the existing 15-inch Highland Creek Interceptor. If construction of this project does not commence within two (2) years of the date of this notice, the notice is rescinded and a second request and notice will be required before flow capacity is accepted. Please notify WSACC, in writing, when construction of this project is initiated. This sewer capacity allocation may also be cancelled pursuant to the conditions set forth in the WSACC Sewer Allocation and Commitment Policy. If you have any questions, please call me at (704) 786-1783, extension 228. Sincerely, is Thomas Hahn, PE Assistant Engineering Director cc: Keri Cantrell, PE/Charlotte Water Michael Wilson/WSACC Chad VonCannon, PE/WSACC Mark Lomax/WSACC Trent Gobble/WSACC WASTEWATER FLOW ACCEPTANCE FORM FOR THE WATER AND SEWER AUTHORITY OF CABARRUS COUNTY Jurisdiction Requesting Flow Acceptance: Date: 01-05-2021 ['City of Concord ❑City of Kannapolis ['Town of Harrisburg DTown of Mt. Pleasant ®Charlotte Water Project Title, Description, and Number of Lots/Unit: Project Title: Eastfield and Prosperity Daycare and Retail —Project #202134 Description: The Eastfield and Prosperity Daycare and Retail engineering plans and specifications, as prepared, by Michael A. Theberge, Bohler Engineering, NC, PLLC, for wastewater sewer laterals to serve Eastfield and Prosperity Daycare and Retail located on 12917 Eastfield Road, Charlotte, NC, with a wastewater discharge of 4,475 GPD. *Number of Lots: OR *Number of Units: 179 persons x 25 gpd/person *Must be included in request. Where will the new line be connected: Directly into a WSACC Interceptor ❑ Into the Jurisdiction's existing collection system ❑ Into a private line Describe the location of the tie-in line to which the new sewer line will connect: The proposed sewer laterals will tie- in to the existing 8-inch sanitary sewer system, which extends to the 15-inch RCP material WSACC Highland Creek Interceptor — Phase 1 Which WSACC Interceptor will the flow ultimately be discharged into: 15-inch RCP WSACC Highland Creek Interceptor — Phase 1. What is the WSACC manhole number that the flow will be discharged into? +/- Node 018848 What is the quantity of flow that will be discharged? 4,475 GPD Flow type: ❑ Domestic % EI Commercial 100 ❑ Industrial Name of wastewater treatment facility (WWTF) receiving wastewater: EK Rocky River Wastewater Treatment Facility — Permit #NC0036269 ❑ Muddy Creek Wastewater Treatment Facility — Permit #NC0081621 Design drawings of new lines will be submitted to WSACC with the request for acceptance. Drawings can be submitted as a digital file (DWG) or distance and bearing starting with the tap on existing infrastructure. If the new line is to connect directly into a WSACC interceptor, detailed drawings including specification of the tap, will be required before flow acceptance will be provided. Mark Lomax at 704-786-1783, ext. 231, must be notified 48 hours in advance of a connection into a WSACC interceptor. WSACC will inspect connection before, during, and after completion. If construction is not started within hvo (2) year from the date of approval of the flow acceptance for this project, the approval is rescinded and a second request and approval will be required for the project. WSACC USE ONLY: DATE: ❑� Current sewer model shows an Interceptor as being surcharged south of the manhole in question. E Approved ❑ Not Approved ❑ Current Sewer Model shows: SiAFFitntr EX..L. Ss CA?Act 'Or +r1 toLLC,L`rIOA `fir" y 1495 f,Rj Eti.A Cri 0/30,v 1-Low cowl (t I Ot State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking for Sewer Extension Applications Dlvlsllt of Water Resources (FTSE —10/18) (WSACC USE ONLY) Eastfield and Prosperity Daycare and Retail (Charlotte Water Project No. 202134) Section I. Name of wastewater treatment facility (WWTF) receiving wastewater: Rocky River Wastewater Treatment Facility — Permit #NC0036269 El Muddy Creek Wastewater Treatment Facility — Permit #NC0081621 WWTP facility's permitted flow, MGD 26.500 Estimated obligated flow not yet tributary to the WWTP, MGD 3.942 WWTP facility's actual avg. daily flow, MGD Total flow for this specific request, MGD Total actual and obligated flows to the facility, MGD Percent of permitted flow used 21.947 (82.82% of permit) 0.004 25.893 97.71% Section II. Pump stations along the route from the Jurisdiction's connection point to the WWTP. Pump Station (Name or Number) Pump Station Permit No. Firm Capacity MGD (A) Design Average Daily Flow ** (Firm/pt) MGD (B) Approx. Current Average Daily Flow MGD (C) Obligated, Not Yet Tributary Daily Flow MGD (D) = (B+C) Total Current Flow Plus Obligated Flow g MGD (E)=(A-D) Availablee* Capacity MGD Lower Rocky NC0036269 37.000 14,800 11.259 3.373 14.632 0.168 River PS * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. **Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pi) not less than 2.S, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. ***A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where Available Capacity is <0. Section III. WSACC Certification Statement: I, J. Thomas Hahn, PE, certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route from the connection to the WSACC interceptor to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Section I and Section II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates WSACC's guarantee of capacity for this wastewater flow. .L. 2c-.1 WSACC's Signing Official Signature Dte ITotal Demand w/ Peak= 3.10 gpm * 2.10 = 6.52 gpm Peak Factor = 2.10 Total Demand = 4,475 gpd * (1 Day/ 24 Hours) * (1 Hour/60 Minutes) = 3.10 gpm Total Demand = 4,475 gpd aycare with 155 Children and 24 Staff _i . _ . Overall Development Eastfield & Prosperity Rd. Full Moon Of Union, LLC Rezoning Petition No. 2013-072 A 25 Gal/Day/Person (Child & Employee) NCDENR Flow Demands (155 + 24) Person * 25 gpd/Person = 4,475 gpd 'Calculated Demand North Carolina Secretary of State Search Results Page 1 of 1 • Upload a PDF Filing • Order a Document Online • Add Entity to My Email Notification List • View Filings Professional Corporation Legal Name Ambrosino DePinto & Schmieder Consulting Engineers, PC Home State Name Ambrosino, DePinto & Schmieder Consulting Engineers, D.P.C. Information Sosld: 1872376 Status: Current -Active 0 Date Formed: 7/25/2019 Citizenship: Foreign State of Incorporation: NY Annual Report Due Date: Registered Agent: LicenseSure LLC Addresses Mailing Principal Office Reg Office 45 Broadway, Suite 1220 45 Broadway, Suite 1220 500 Westover Dr #5526 New York, NY 10006 New York, NY 10006 Sanford, NC 27330 Reg Mailing 500 Westover Dr #5526 Sanford, NC 27330 Professions Engineering services https://www.sosnc.gov/online_services/search/Business_Registration_Results 4/20/2021