Loading...
HomeMy WebLinkAboutSW3210402_2021-04-14 - Cuthbertson Townhomes - 1st Submittal_20210426CLIENT Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-CS1.dwg, 4/14/2021 3:23:23 PM, Bernard, AndrewThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CONTACT PROJECT DIRECTORY REVISIONS N0.DATE CONSTRUCTION DRAWINGS FOR: CUTHBERTSON TOWNHOMES UNION COUNTY NORTH CAROLINA, 28173 PROJECT NUMBER: DWH-19010 FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 SITE VICINITY MAP NTS 16 CUTHBERTSON RDGRAY B Y R U M R D PINE OAK R D SKI TR AI L L N MI L L P O N D D R MARC VAN DINE vandine@mcadamsco.com PHONE: 704.527.0800 CUTHBERTSON ROAD UNION COUNTY, NORTH CAROLINA, 28173 CONSTRUCTION DRAWINGS PROJECT NUMBER: DWH-19010 DATE: APRIL 14, 2021 CUTHBERTSON TOWNHOMES SHEET INDEX SEALED DATE REVISION # C COVER SHEET 04. 14. 2021 C0.00 PROJECT NOTES 04. 14. 2021 C1.00 TOPOGRAPHIC SURVEY (BY OTHERS)03. 09. 2021 C1.01 TREE SURVEY (BY OTHERS)03. 09. 2021 C1.02 TREE SURVEY (BY OTHERS)03. 09. 2021 C1.03 FINAL PLAT (BY OTHERS)02. 18. 2021 C1.04 FINAL PLAT (BY OTHERS)02. 18. 2021 C1.05 FINAL PLAT (BY OTHERS)02. 18. 2021 C2.00 OVERALL SITE PLAN 04. 14. 2021 C3.00 OVERALL GRADING & STORM DRAINAGE PLAN 04. 14. 2021 C3.01 GRADING & STORM DRAINAGE PLAN - S 04. 14. 2021 C3.02 GRADING & STORM DRAINAGE PLAN - N 04. 14. 2021 C3.03 STORM DRAINAGE SCHEDULE 04. 14. 2021 C5.00 PLAN AND PROFILE - ENCORE LANE STA. 10+00 THRU STA. 12+08.51 04. 14. 2021 C5.01 PLAN AND PROFILE - STREET 'A' STA. 10+00 THRU STA. 19+93.33 04. 14. 2021 C5.02 PLAN AND PROFILE - STREET 'B' STA. 10+00 THRU STA. 17+50 04. 14. 2021 C5.03 PLAN AND PROFILE - STREET 'B' STA. 17+50 THRU STA. 25+40.96 04. 14. 2021 C5.04 PLAN AND PROFILE - STREET 'C' STA. 10+00 THRU STA. 15+98.93 04. 14. 2021 C5.05 PLAN AND PROFILE - LINE OF SIGHT INTERSECTION OF ENCORE LANE AND CUTHBERTSON RD 04. 14. 2021 C5.06 PLAN AND PROFILE - LINE OF SIGHT INTERSECTION OF STREET 'A' AND CUTHBERTSON RD 04. 14. 2021 C5.07 PLAN AND PROFILE - LINE OF SIGHT INTERSECTION OF ENCORE LANE AND STREET 'A'04. 14. 2021 C5.08 PLAN AND PROFILE - LINE OF SIGHT INTERSECTION OF STREET 'B' AND STREET 'A'04. 14. 2021 C5.09 PLAN AND PROFILE - LINE OF SIGHT INTERSECTION OF STREET 'C' AND STREET 'A'04. 14. 2021 C5.10 PLAN AND PROFILE - LINE OF SIGHT INTERSECTION OF STREET 'C' AND STREET 'B'04. 14. 2021 C6.00 OVERALL EROSION & SEDIMENT CONTROL PLAN - STAGE I 04. 14. 2021 C6.01 EROSION & SEDIMENT CONTROL PLAN - STAGE I - S 04. 14. 2021 C6.02 EROSION & SEDIMENT CONTROL PLAN - STAGE I - N 04. 14. 2021 C6.03 OVERALL EROSION & SEDIMENT CONTROL PLAN - STAGE II 04. 14. 2021 C6.04 EROSION & SEDIMENT CONTROL PLAN - STAGE II - S 04. 14. 2021 C6.05 EROSION & SEDIMENT CONTROL PLAN - STAGE II - N 04. 14. 2021 C6.06 OVERALL EROSION & SEDIMENT CONTROL PLAN - STAGE III 04. 14. 2021 C6.07 EROSION & SEDIMENT CONTROL PLAN - STAGE III - S 04. 14. 2021 C6.08 EROSION & SEDIMENT CONTROL PLAN - STAGE III - N 04. 14. 2021 C6.09 EROSION & SEDIMENT CONTROL DETAILS 04. 14. 2021 C6.10 EROSION & SEDIMENT CONTROL DETAILS 04. 14. 2021 C6.11 EROSION & SEDIMENT CONTROL DETAILS 04. 14. 2021 C8.00 SITE DETAILS 04. 14. 2021 C8.01 STORM DRAINAGE DETAILS 04. 14. 2021 C8.02 STORM DRAINAGE DETAILS 04. 14. 2021 C9.00 STORMWATER CONTROL MEASURE "A" PLAN VIEW 04. 14. 2021 C9.01 STORMWATER CONTROL MEASURE "A" DETAILS 04. 14. 2021 C9.02 STORMWATER CONTROL MEASURE "A" DETAILS 04. 14. 2021 C9.03 STORMWATER CONTROL MEASURE "A" LANDSCAPE PLAN 04. 14. 2021 C9.100 STORMWATER CONTROL MEASURE "B" PLAN VIEW 04. 14. 2021 C9.101 STORMWATER CONTROL MEASURE "B" DETAILS 04. 14. 2021 C9.102 STORMWATER CONTROL MEASURE "B" DETAILS 04. 14. 2021 C9.103 STORMWATER CONTROL MEASURE "B" DETAILS 04. 14. 2021 LS2.00 LANDSCAPE PLAN OVERALL 04. 12. 2021 LS2.01 LANDSCAPE PLAN - S 04. 12. 2021 LS2.02 LANDSCAPE PLAN - N 04. 12. 2021 LS2.03 LANDSCAPE NOTES AND DETAILS 04. 12. 2021 C0.00 N / A PROJECT NOTES CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-N1.dwg, 4/14/2021 10:33:49 AM, Bernard, AndrewThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-N1 CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R GENERAL NOTES: 1.ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE OWNER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO THE CONTRACTOR FOR ANY WORK DONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF SUCH NOTIFICATION HAS NOT BEEN GIVEN. 2.MEASUREMENTS ARE TO THE EDGE OF PAVEMENT UNLESS OTHERWISE NOTED. CONTRACTOR TO VERIFY ALL DIMENSIONS AND GRADES PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE OWNER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO THE CONTRACTOR FOR ANY WORK DONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF SUCH NOTIFICATION HAS NOT BEEN GIVEN. 3.THERE ARE WETLANDS WITHIN THIS SITE. IT IS THE OWNER'S RESPONSIBILITY FOR WETLANDS JURISDICTION AND PERMIT DISTURBANCE PRIOR TO ANY GRADING ACTIVITY. 4.FLOOD NOTE: PORTIONS OF THIS PROPERTY ARE LOCATED IN SPECIAL FLOOD HAZARD ZONE "AE" AS DEFINED BY FEMA F.I.R.M. MAP NOS. 3710447400J, DATED OCTOBER 16, 2008. 5.WITHIN THE SIGHT DISTANCE TRIANGLES SHOWN, NO OBSTRUCTION BETWEEN 30" AND 72" IN HEIGHT ABOVE THE CURB LINE ELEVATION SHALL BE LOCATED IN WHOLE OR IN PART. OBSTRUCTIONS INCLUDE BUT ARE NOT LIMITED TO ANY BERM, FOLIAGE, FENCE, WALL, SIGN, OR PARKED VEHICLE. 6.ALL CONSTRUCTION SHALL CONFORM TO THE LATEST UNION COUNTY, UNION COUNTY PUBLIC WORKS, AND NCDOT STANDARDS AND SPECIFICATIONS. 7.OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS FOR EXCAVATIONS; FINAL RULE 29CFR PART 1926, SUBPART "P" APPLIES TO ALL EXCAVATIONS EXCEEDING FIVE (5) FEET IN DEPTH. EXCAVATION EXCEEDING TWENTY (20) FEET IN DEPTH REQUIRES THE DESIGN OF A TRENCH SAFETY SYSTEM BY A REGISTERED PROFESSIONAL ENGINEER, PROVIDED BY CONTRACTOR RESPONSIBLE FOR EXCAVATION. 8.EQUIPMENT AND PRODUCTS OTHER THAN THOSE SPECIFIED MAY BE USED PROVIDED APPROVAL HAS BEEN OBTAINED FROM THE OWNER IN WRITING PRIOR TO ORDERING OR INSTALLATION. THE CONTRACTOR SHALL WAIVE ANY CLAIM FOR ADDITIONAL COST RELATED TO THE SUBSTITUTION OF ALTERNATE EQUIPMENT. 9.CONTRACTOR SHALL MAINTAIN AN "AS-BUILT" SET OF DRAWINGS TO RECORD THE EXACT LOCATION OF ALL PIPING PRIOR TO CONCEALMENT. DRAWINGS SHALL BE GIVEN TO THE OWNER UPON COMPLETION OF THE PROJECT WITH A COPY OF THE TRANSMITTAL LETTER TO THE ENGINEER. 10.EXISTING IMPROVEMENTS SLATED TO REMAIN THAT ARE DAMAGED DURING CONSTRUCTION SHALL BE REPLACED/RESTORED TO THEIR ORIGINAL CONDITION OR TO THE SATISFACTION OF THE OWNER BY THE CONTRACTOR RESPONSIBLE FOR THE DAMAGE. 11.SOIL UNDER BUILDINGS AND PAVED AREAS SHALL BE COMPACTED TO STANDARD PROCTOR MAXIMUM DRY DENSITY OR AS RECOMMENDED BY THE GEOTECHNICAL ENGINEER. 12.THE CONTRACTOR SHALL NOTE THAT THE DRAWINGS MAY NOT SHOW EVERY OFFSET, TRANSITION, FITTING, ETC. THAT MAY BE REQUIRED. THE CONTRACTOR SHALL INSTALL SUCH STANDARD APPURTENANCES AS REQUIRED TO CLOSELY FOLLOW THE GRADES AND ALIGNMENTS DEPICTED ON THE PLANS. 13.CONTRACTOR SHALL NOTIFY "NORTH CAROLINA 811" (1-800-632-4949) AT LEAST 48 HOURS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR TO CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NORTH CAROLINA ONE CALL". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. 14.CONTRACTOR IS RESPONSIBLE FOR COORDINATING CONSTRUCTION ACTIVITIES WITH THE APPROPRIATE UTILITY COMPANIES FOR ANY REQUIRED RELOCATION (I.E. POWER POLES, TELEPHONE PEDESTALS, WATER METERS, ETC.). 15.EXISTING UTILITIES SHOWN ARE BASED ON FIELD SURVEYS AND THE BEST AVAILABLE RECORD DRAWINGS. THE CONTRACTOR SHALL VERIFY CONDITIONS PRIOR TO BEGINNING CONSTRUCTION. ANY DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND THE PLANS SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. 16.PRIOR TO STARTING CONSTRUCTION, THE GENERAL CONTRACTOR SHALL HOLD A PRE-CONSTRUCTION CONFERENCE. 17.PAVEMENT SECTIONS SHALL BE CONFIRMED BY GEOTECHNICAL ENGINEER PRIOR TO BEGINNING CONSTRUCTION. TOTAL DISTURBED AREA = 16.50 AC. RETAINING WALL NOTES 1.THE RETAINING WALL ALIGNMENT SHOWN ON THESE PLANS DEPICTS THE LOCATION OF THE FRONT FACE OF THE RETAINING WALL AT THE TOP OF THE WALL. THE CONTRACTOR IS RESPONSIBLE FOR ENSURING RETAINING WALLS ARE NOT LOCATED IN ANY STREAM BUFFERS, AND THEIR CONSTRUCTION DOES NOT ENCROACH INTO ANY ADJACENT PROPERTIES DUE TO ANY BATTER INCORPORATED IN THE DESIGN OF THE WALLS. 2.RETAINING WALLS ARE TO BE DESIGN-BUILD PROJECTS BY THE CONTRACTOR. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN FINAL CONSTRUCTION DRAWINGS FROM A REGISTERED ENGINEER AND GAIN ALL REQUIRED PERMITS NECESSARY FOR THE CONSTRUCTION OF THE RETAINING WALLS. 3.RETAINING WALLS SHALL BE ASSUMED TO BE BACKFILLED WITH OFF-SITE BORROW MATERIAL OR PROCESSED FILL, UNLESS THE CONTRACTOR CAN PROVIDE TO THE OWNER WITH CONFIRMATION FROM THE GEOTECHNICAL ENGINEER AND THE RETAINING WALL DESIGNER, THAT READILY AVAILABLE ON-SITE SOILS CAN BE USED. 4.THE TOP AND BOTTOM OF WALL ELEVATIONS SHOWN ON THESE PLANS IDENTIFY FINISHED GRADE ELEVATIONS ONLY. THE EXTENT THAT THE RETAINING WALL WILL BE EXTENDED BELOW GRADE TO THE FOOTING OR ABOVE GRADE TO THE TOP OF THE CAP BLOCK COURSE SHALL BE IDENTIFIED ON THE RETAINING WALL CONSTRUCTION DRAWINGS. 5.ALL RETAINING WALLS OVER 30" HIGH SHALL HAVE A SAFETY FENCE (DESIGN BY OTHERS). 6.ANY PART OF ANY RETAINING WALL THAT EXTENDS INTO THE RIGHT-OF-WAY WILL REQUIRE AN ENCROACHMENT AGREEMENT. ENCROACHMENT AGREEMENTS FOR RETAINING WALLS SHALL BE APPROVED PRIOR TO CONSTRUCTION DRAWING APPROVAL. 7.ANY TIEBACK SYSTEMS FOR THE RETAINING WALLS SHALL NOT BE ALLOWED WITHIN PUBLIC RIGHT-OF-WAY. 8.STORMWATER RUN-OFF SHALL BE DIRECTED AWAY FROM RETAINING WALLS. ANY RUN-OFF FLOWING TO AND OVER A RETAINING WALL SHALL BE KEPT TO AN ABSOLUTE MINIMUM AND BROUGHT TO THE ATTENTION OF THE WALL DESIGNER PRIOR TO THEIR DESIGN. GROUND STABILIZATION SITE AREA DESCRIPTION STABILIZATION TIME FRAME STABILIZATION TIME FRAME EXCEPTIONS PERIMETER DIKES, SWALES, DITCHES AND SLOPES 7 DAYS NONE HIGH QUALITY WATER (HQW) ZONES 7 DAYS NONE SLOPES STEEPER THAN 3:1 7 DAYS IF SLOPES ARE 10' OR LESS IN LENGTH AND ARE NOT STEEPER THAN 2:1, 14 DAYS ARE ALLOWED SLOPES 3:1 OR FLATTER 14 DAYS 7-DAYS FOR SLOPES GREATER THAN 50 FEET IN LENGTH ALL OTHER AREAS WITH SLOPES FLATTER THAN 4:1 14 DAYS NONE (EXCEPT FOR PERIMETERS AND HQW ZONES) DEMOLITION NOTES: 1.THE CONTRACTOR SHALL FIELD VERIFY AND LOCATE ALL EXISTING UTILITIES ON SITE PRIOR TO DEMOLITION. 2.THE CONTRACTOR SHALL PERFORM DEMOLITION ACTIVITIES AS NOTED AND SHOWN ON THESE PLANS AND AS DIRECTED BY THE OWNER. 3.IT WILL BE THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN ANY PERMITS AND PAY FEES REQUIRED FOR DEMOLITION AND HAUL-OFF FROM THE APPROPRIATE AUTHORITIES. THESE FEES ARE TO BE INCLUDED WITH THE BID. 4.THE CONTRACTOR SHALL PREPARE ALL DOCUMENTS AND ACQUIRE APPROPRIATE PERMITS AS REQUIRED PRIOR TO THE COMMENCEMENT OF DEMOLITION. 5.THE DEMOLITION PLAN IS INTENDED TO DEPICT GENERAL DEMOLITION AND UTILITY WORK. IT IS NOT INTENDED TO IDENTIFY EACH ELEMENT OF DEMOLITION OF RELOCATION. CONTRACTOR SHALL COORDINATE WITH THE OWNER AND APPROPRIATE UTILITY COMPANY PRIOR TO WORK. 6.CONTRACTOR TO COMPLETELY DEMOLISH AND DISPOSE OF OFFSITE IN A LAWFUL MANNER EXISTING BUILDINGS, INCLUDING FOUNDATIONS AND ALL APPURTENANCES LOCATED ON AND AROUND THE PROPERTY INCLUDING BUT NOT LIMITED TO CURBS, SIDEWALKS, TREES AND SHRUBS. 7.ALL MATERIAL TO BE DEMOLISHED SHALL BE REMOVED FROM THE SITE AND DISPOSED OF AT A PERMITTED SITE IN ACCORDANCE WITH ALL LOCAL, STATE AND FEDERAL LAWS. 8.REMOVE AND DISPOSE OF ANY SIDEWALK, FENCES, STAIRS, WALLS, FOUNDATIONS, CONDUITS, LIGHT POLE BASES, DEBRIS AND RUBBISH REQUIRING REMOVAL FROM THE WORK AREA IN AN APPROVED LANDFILL. 9.REMOVE AND/OR PLUG EXISTING UTILITIES SUCH AS SANITARY SEWER, WATER, GAS, ELECTRIC, AND TELEPHONE AS SHOWN. THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING EACH UTILITY COMPANY TO COORDINATE REMOVAL OF ALL UTILITIES AND FOR DETERMINING HORIZONTAL AND VERTICAL LOCATIONS OF UTILITIES PRIOR TO COMMENCING WORK. 11. THE CONTRACTOR SHALL CUT AND PLUG, OR ARRANGE FOR THE APPROPRIATE UTILITY COMPANY TO CUT AND PLUG ALL SERVICE PIPING AT THE STREET LINE OR MAIN, AS REQUIRED, OR AS OTHERWISE NOTED. ALL SERVICES MAY NOT BE SHOWN ON THE PLAN. THE CONTRACTOR SHALL INVESTIGATE THE SITE PRIOR TO BIDDING TO DETERMINE THE EXTEND OF SERVICE PIPING TO BE REMOVED, CUT OR PLUGGED. 10.CONTRACTOR SHALL COORDINATE WITH UTILITY DEPARTMENT IN THE REMOVAL/RELOCATION OF EXISTING POWER POLES AND OVERHEAD POWER LINES. 11.THE CONTRACTOR SHALL ARRANGE FOR RESETTING OF CURB BOXES, VALVE BOXES AND REMOVAL AND/OR RELOCATION OF OVERHEAD UTILITIES AND POLES WITH THE APPROPRIATE UTILITY COMPANY. 12.INSTALL ALL EROSION AND SEDIMENT CONTROL DEVICES AND TREE PROTECTION PRIOR TO BEGINNING DEMOLITION WORK. 13.THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF ALL UTILITIES TO REMAIN IN PLACE. 14.THE CONTRACTOR IS RESPONSIBLE TO REPLACE ANY TREES THAT ARE DAMAGED DURING CONSTRUCTION THAT ARE TO BE PROTECTED AS SHOWN ON THE PLANS. 15.THE CONTRACTOR SHALL TAKE ALL PRECAUTIONS TO AVOID UNNECESSARY DAMAGE TO EXISTING ROAD SURFACE. 16.FINISH SURFACE TO BE REMOVED OR DEMOLISHED SHALL BE CUT ALONG LINES OF JOINTS WHICH WILL PERMIT A NEAT SURFACE WHEN RESTORED. 17.SAWCUT AT INTERFACE OF PAVEMENT OR CURB TO REMAIN. SAWCUT EXISTING PAVEMENT AT THE R/W. 18.ALL EXISTING ITEMS TO REMAIN WHICH ARE DAMAGED DURING CONSTRUCTION SHALL BE RESTORED TO ITS ORIGINAL CONDITION AT THE SOLE EXPENSE OF THE CONTRACTOR. 19.THE CONTRACTOR SHALL MAINTAIN ALL UTILITY SERVICES TO THE ADJOINING PROPERTIES DURING THE DEMOLITION PROCESS. 20.DO NOT INTERRUPT EXISTING UTILITIES SERVICING FACILITIES OCCUPIED AND USED BY THE OWNER OR OTHERS DURING OCCUPIED HOURS EXCEPT WHEN SUCH INTERRUPTIONS HAVE BEEN AUTHORIZED IN WRITING BY THE OWNER AND THE LOCAL MUNICIPALITIES. INTERRUPTIONS SHALL ONLY OCCUR AFTER ACCEPTABLE TEMPORARY SERVICE HAS BEEN PROVIDED. 21.SHOULD ANY UNCHARTED OR INCORRECTLY CHARTED EXISTING PIPING OR OTHER UTILITY BE UNCOVERED DURING EXCAVATION, CONSULT THE ENGINEER IMMEDIATELY FOR DIRECTIONS BEFORE PROCEEDING FURTHER WITH WORK IN THE IS AREA. 22.ASBESTOS OR HAZARDOUS MATERIAL, IF FOUND ON SITE, SHALL BE REMOVED BY A LICENSED HAZARDOUS MATERIAL CONTRACTOR. 23.IN ACCORDANCE WITH 40 CFR, PART 61, SUBPART M, A THOROUGH INSPECTION SHALL BE CONDUCTED FOR ASBESTOS-CONTAINING MATERIALS, PRIOR TO CONDUCTING A RENOVATION OR DEMOLITION ACTIVITY OF AN EXISTING STRUCTURE. THE ASBESTOS INSPECTION MUST BE CONDUCTED BY A NORTH CAROLINA ACCREDITED ASBESTOS INSPECTOR. ALL REGULATED AND/OR FRIABLE ASBESTOS-CONTAINING MATERIALS IDENTIFIED DURING THE SURVEY, WHICH WILL BE DISTURBED, MUST BE PROPERLY REMOVED BY ACCREDITED INDIVIDUALS BEFORE BEGINNING THE RENOVATION OR DEMOLITION ACTIVITY. IF REGULATED AND/OR FRIABLE ASBESTOS CONTAINING MATERIALS TO BE REMOVED EXCEED 160 SQUARE FEET, 260 LINEAR FEET OR 35 CUBIC FEET, A PERMIT SHALL BE APPLIED FOR THROUGH THE NORTH CAROLINA DEPARTMENT OF HEALTH AND HUMAN SERVICES. 24.UTILITY APPURTENANCES TO BE REMOVED INCLUDE BUT ARE NOT LIMITED TO HYDRANTS, FIRE DEPARTMENT CONNECTIONS, VALVES/VALVE BOXES, STORM DRAIN AND/OR SANITARY SEWER CLEANOUTS, STORM DRAIN INLETS. STORM DRAINAGE NOTES: 1.ALL WORK AND MATERIALS SHALL CONFORM TO THE LATEST EDITION OF THE UNION COUNTY, UNION COUNTY PUBLIC WORKS DETAILS AND SPECIFICATIONS, AND NCDOT STANDARD SPECIFICATIONS UNLESS OTHERWISE SPECIFIED IN THIS MANUAL. 2.ALL STORM DRAINAGE PIPES SHOWN SHALL BE REINFORCED CONCRETE (RCP) (MINIMUM CLASS III) UNLESS NOTED OTHERWISE. CONTRACTOR TO COORDINATE WITH THE GEOTECH TO VERIFY TYPE OF BEDDING REQUIRED BASED ON SOIL CONDITIONS. CONTRACTOR TO SELECT REQUIRED CLASS OF PIPE BASED ON DEPTH OF PIPE AND BEDDING PROVIDED PER THE AMERICAN CONCRETE PIPE ASSOCIATION GUIDELINES. 3.ONLY REINFORCED CONCRETE PIPE IS ALLOWED WITHIN THE PUBLIC ROW AND FOR PUBLIC STORM PIPE. 4.ALL PRIVATE STORM DRAINAGE PIPE SHALL BE REINFORCED CONCRETE PIPE, CONTECH CORRUGATED METAL PIPE, CORRUGATED METAL PIPE, OR HIGH DENSITY POLYETHYLENE (HDPE) PIPE, AS APPROVED BY THE CEC. NO OTHER TYPE OF PIPE SHALL BE USED WITHOUT PRIOR APPROVAL FROM THE CEC. ALL PIPES SHALL BE LAID WITH THE BELL OR GROOVE UPGRADE AND THE JOINT ENTIRELY INTERLOCKING. 5.ALL CONCRETE SHALL BE 3600 PSI COMPRESSIVE STRENGTH. IN ORDER TO USE PRE-CAST STORM DRAINAGE STRUCTURES IN ANY STREET RIGHTS-OF-WAY, PRIOR APPROVAL SHALL BE OBTAINED FROM THE CITY/COUNTY ENGINEER. 6.ALL HIGH-DENSITY POLYETHYLENE PIPE SHALL BE CORRUGATED EXTERIOR/SMOOTH INTERIOR, CONFORM TO THE REQUIREMENTS OF AASHTO SPECIFICATION M294 FOR CORRUGATED POLYETHYLENE PIPE AND SHALL REQUIRE COUPLING BANDS AND FITTINGS. 7.CONCRETE PIPE USED WITHIN THE STREET RIGHT-OF-WAY SHALL BE A MINIMUM OF CLASS III REINFORCED CONCRETE PIPE, WITH A MINIMUM DIAMETER OF FIFTEEN (15) INCHES (EIGHTEEN (18) INCHES MINIMUM ON CROSS DRAIN CULVERTS WITHIN THE COUNTY). 8.THE MINIMUM COVER FOR ALL PIPE IS TWO (2) FEET. SPECIAL APPLICATIONS FOR LESS THAN TWO (2) FEET OF COVER WILL BE REVIEWED INDIVIDUALLY. 9.CONCRETE MORTAR JOINTS SHALL BE USED FOR JOINING ALL CONCRETE PIPES. THE PIPE SHALL BE CLEAN AND MOIST WHEN MORTAR IS APPLIED. THE LOWER PORTIONS OF THE BELL OR GROOVE SHALL BE FILLED WITH MORTAR SUFFICIENT TO BRING THE INNER SURFACE FLUSH AND EVEN WHEN THE NEXT JOINT IS FITTED INTO PLACE. THE REMAINDER OF THE JOINT SHALL THEN BE FILLED WITH MORTAR AND A BEAD OR RING OF MORTAR FORMED AROUND THE OUTSIDE OF THE JOINT. THE APPLICATION OF INTERIOR MORTAR MAY BE DELAYED UNTIL BACKFILL IS COMPLETED WHEN THE PIPE IS LARGER THAN THIRTY (30) INCHES. 10.PREFORMED JOINT SEALER, WHICH CONFORMS TO AASHTO SPECIFICATION M-198 FOR TYPE B FLEXIBLE PLASTIC GASKETS, MAY BE USED IN LIEU OF THE MORTAR JOINING METHOD. 11.COUPLING BANDS AND FITTINGS SHALL BE USED FOR JOINING ALL HDPE PIPE. COUPLING BANDS SHALL COVER AT LEAST ONE FULL CORRUGATION ON EACH SECTION OF PIPE. GASKET COUPLING BANDS ARE REQUIRED BETWEEN ALL PIPE JOINTS. THE GASKET SHALL BE MADE OF CLOSED-CELL SYNTHETIC EXPANDED RUBBER MEETING THE REQUIREMENTS OF ASTM D1056, TYPE 2. THE PIPE MANUFACTURER SHALL INSTALL GASKETS ON THE COUPLING BAND. ALL COUPLING BANDS SHALL MEET OR EXCEED THE SOIL-TIGHTNESS REQUIREMENT OF AASHTO STANDARD SPECIFICATION FOR HIGHWAY BRIDGES, SECTION 23, PARAGRAPH 23.1.5.4(E). PIPEFITTINGS SHALL CONFORM TO AASHTO M252 OR AASHTO M294. 12.THE INTERIOR SURFACES OF ALL STORM DRAINAGE STRUCTURES SHALL BE POINTED UP AND SMOOTHED TO AN ACCEPTABLE STANDARD USING MORTAR MIXED TO MANUFACTURER'S SPECIFICATIONS. 13.ALL PIPES IN STORM DRAIN STRUCTURES SHALL BE FLUSH WITH THE INSIDE WALL. 14.ANY STORM DRAIN STRUCTURES OVER THREE (3) FEET AND SIX (6) INCHES IN HEIGHT MUST HAVE STEPS IN ACCORDANCE WITH STANDARD DETAILS. 15.ALL FRAMES, GRATES, RINGS, COVERS, ETC., MUST CONFORM TO THE STANDARDS. 16.ALL GRADED CREEK BANKS AND SLOPES SHALL BE AT A MAXIMUM OF TWO (2) FEET HORIZONTAL TO ONE (1) FOOT VERTICAL (2:1) AND NOT TO EXCEED 10' WITHOUT SLOPE STABILIZATION. 17.ALL BACKFILL SHALL BE NON-PLASTIC IN NATURE, FREE FROM ROOTS, VEGETATIVE MATTER, WASTE, CONSTRUCTION MATERIAL OR OTHER OBJECTIONABLE MATERIAL. SAID MATERIAL SHALL BE CAPABLE OF BEING COMPACTED BY MECHANICAL MEANS AND SHALL HAVE NO TENDENCY TO FLOW OR BEHAVE IN A PLASTIC MANNER UNDER THE TAMPING BLOWS OR PROOF ROLLING. 18.MATERIALS DEEMED BY THE GEOTECH OR ENGINEER AS UNSUITABLE FOR BACKFILL PURPOSES SHALL BE REMOVED AND REPLACED WITH SELECT BACKFILL MATERIAL. 19.BACKFILLING OF TRENCHES SHALL BE ACCOMPLISHED IMMEDIATELY AFTER THE PIPE IS LAID. THE FILL AROUND THE PIPE SHALL BE PLACED IN LAYERS NOT TO EXCEED EIGHT (8) INCHES, EACH LAYER SHALL BE THOROUGHLY COMPACTED TO 95% OF THE MAXIMUM DENSITY OBTAINABLE WITH THE STANDARD PROCTOR TEST (A DENSITY OF 100% STANDARD PROCTOR IS REQUIRED FOR THE TOP EIGHT (8) INCHES). 20.COMPACTION REQUIREMENTS SHALL BE ATTAINED BY THE USE OF MECHANICAL COMPACTION METHODS. EACH LAYER OF BACKFILL SHALL BE PLACED LOOSE AND THOROUGHLY COMPACTED IN PLACE. 21.UNDER NO CIRCUMSTANCES SHALL WATER BE PERMITTED TO RISE IN UNBACKFILLED TRENCHES AFTER THE PIPE HAS BEEN PLACED. 22.IF THE USE OF WAFFLE BOXES ARE ALLOWED AT THIS SITE, ALL PENETRATIONS FOR STORM DRAINAGE PIPES MUST BE MADE WITHIN THE KNOCK-OUT PORTION OF THE BOX AND NOT AT THE CORNERS WHERE THE STRUCTURAL INTEGRITY MAY BE COMPROMISED. CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-OAS1.dwg, 4/14/2021 2:09:24 PM, Bernard, AndrewThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-OAS1 C2.00 1"=60' OVERALL SITE PLAN GRAPHIC SCALE 0 30 60 120 1 inch = 60 ft. EXISTING CUTHBERTSON ROAD (PUBLIC R/W) ENCORE LANE (50' PUBLIC R/W) STREET 'A' (50' PUBLIC R/W) ST R E E T ' B ' (5 0 ' P U B L I C R / W ) S T R E E T ' C ' ( 5 0 ' P U B L I C R /W ) STORMWATER CONTROL MEASURE "A" STORMWATER CONTROL MEASURE "B" 10987654321 15 46 88 25 11 12 13 14 26 27 45 44 4387 86 89 16 17 18 19 20 28 29 30 31 32 33 34 35 53 81 82 83 84 85 80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 64 63 58 59 62 60 61 54 55 56 57 21 22 23 24 42 41 40 39 38 37 36 474850515249 90 91 92 93 SITE LEGEND CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R SITE VICINITY MAP NTS 16 CUTHBERTSON RDGRAY B Y R U M R D PINE OAK R D SKI TR AI L L N MI L L P O N D D R ENVIRONMENTAL HEALTH LAND USE NOTE: ·ANY WELLS AND/OR ON-SITE WASTEWATER DISPOSAL SYSTEMS DISCOVERED DURING THE SITE DEVELOPMENT PROCESS WILL BE ABANDONED IN ACCORDANCE WITH APPLICABLE NORTH CAROLINA LAWS AND RULES. ·NO ON-SITE WASTEWATER DISPOSAL SYSTEMS OR WELLS WERE LOCATED. PROPOSED USE: SITE AREA: UNIT COUNT: LOT DENSITY: TOWNHOMES ±43.547 AC 93 2.14 UNITS/AC SITE DATA PID: EXISTING ZONING: 061-35-002 R-4(CZ) MINIMUM SETBACKS FRONT: SIDE: REAR: CORNER: 20' 5' (APPLIES TO END UNITS ONLY) 25' 10' DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD, SUITE 275 CHARLOTTE, NC 28277 ATTN: SHANNON BOLING SBOLING@DWHOMES.COM 704. 972. 4205 WALTER ROBERT PFISTER & CHRISTINE L. PFISTER ATTN: SHANNON BOLING SBOLING@DWHOMES.COM 704. 972. 4205 THE JOHN R. MCADAMS COMPANY 3430 TORINGDON WAY, SUITE 110 CHARLOTTE, NC 28277 704.527.0800 ATTN: MARC VAN DINE VANDINE@MCADAMSCO.COM DEVELOPER/APPLICANT: PROPERTY OWNER: ENGINEER OF RECORD: TREE-SAVE AREA PROVIDED: OPEN SPACE: AREA OF SITE IN 100-YR FLOODPLAIN: ANTICIPATED START DATE: ANTICIPATED FINISH DATE: ±6.18 AC ±31.3 AC ±22.84 AC SEPTEMBER 2021 APRIL 2023 ·THOUGH IT MAY NOT BE ILLUSTRATED, SHOWN, LISTED, DENOTED, OR EXPRESSED: THIS PLAN SHALL COMPLY WITH ALL PROVISIONS OF THE UNION COUNTY DEVELOPMENT ORDINANCE AT TIME OF REVIEW AND APPROVAL ·ALL TOWNHOMES ARE TO BE SERVED BY COUNTY WATER AND SEWER SEE SHEET C0.00 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE AND UTILITY NOTES CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-OAG1.dwg, 4/14/2021 10:34:40 AM, Bernard, AndrewThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-OAG1 C3.00 1"=60' OVERALL GRADING & GRAPHIC SCALE 0 30 60 120 1 inch = 60 ft. EXISTING CUTHBERTSON ROAD (PUBLIC R/W)ENCORE LANE(50' PUBLIC R/W)STREET 'A ' (50' PUB L I C R / W ) ST R E E T ' B ' (5 0 ' P U B L I C R / W ) S T R E E T ' C ' ( 5 0 ' PU B L I C R /W ) STORMWATER CONTROL MEASURE "B" (SEE C9.00 SHEETS) 10987654321 15 46 88 25 11 12 13 14 26 27 45 44 4387 86 89 16 17 18 19 20 28 29 30 31 32 33 34 35 81 82 83 84 85 80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 64 63 58 59 62 60 61 54 21 22 23 24 42 41 40 39 38 37 36 474850515249 90 91 92 93 CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R GRADING LEGEND 53 55 56 57 STORMWATER CONTROL MEASURE "A" (SEE C9.00 SHEETS) STORM DRAINAGE PLAN TREE PROTECTION NOTES: ·PROPERTY OWNERS ARE RESPONSIBLE FOR ENSURING THAT ALL EXISTING TREES SHOWN ON APPROVED PLANS AS BEING RETAINED TO MEET THE REQUIREMENTS OF THIS ARTICLE ARE PROTECTED DURING THE CONSTRUCTION PROCESS FROM REMOVAL, DESTRUCTION, OR INJURY. BEFORE ANY EXCAVATION TAKES PLACE ON THE SUBJECT SITE, A BARRIER MUST BE ERECTED AROUND THE DRIP LINE OF ALL SUCH TREES SUFFICIENT TO PUT ON NOTICE ALL CONSTRUCTION PERSONNEL THAT ANY DISTURBANCE OF THE AREA WITHIN THE DRIPLINE OF SUCH TREES IS PROHIBITED, EXCEPT AS EXPRESSLY APPROVED BY THE ADMINISTRATOR. REQUIRED TREE BARRIERS MUST BE SHOWN ON CONSTRUCTION PLANS ·FOR PRESERVED VEGETATION, MAINTENANCE SHALL BEGIN AT THE TIME THAT THE ROOT PROTECTION ZONES ARE ESTABLISHED (PRIOR TO ROUGH GRADING) AND SHALL CONTINUE INDEFINITELY. FOR PLANTED MATERIALS, MAINTENANCE SHALL BEGIN AT THE TIME OF PLANTING AND SHALL CONTINUE INDEFINITELY SITE LEGEND DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD, SUITE 275 CHARLOTTE, NC 28277 ATTN: SHANNON BOLING SBOLING@DWHOMES.COM 704. 972. 4205 WALTER ROBERT PFISTER & CHRISTINE L. PFISTER ATTN: SHANNON BOLING SBOLING@DWHOMES.COM 704. 972. 4205 THE JOHN R. MCADAMS COMPANY 3430 TORINGDON WAY, SUITE 110 CHARLOTTE, NC 28277 704.527.0800 ATTN:MARC VAN DINE VANDINE@MCADAMSCO.COM 704.537.0800 DEVELOPER/APPLICANT: PROPERTY OWNER: ENGINEER OF RECORD: ENVIRONMENTAL HEALTH LAND USE NOTE: ·ANY WELLS AND/OR ON-SITE WASTEWATER DISPOSAL SYSTEMS DISCOVERED DURING THE SITE DEVELOPMENT PROCESS WILL BE ABANDONED IN ACCORDANCE WITH APPLICABLE NORTH CAROLINA LAWS AND RULES. ·NO ON-SITE WASTEWATER DISPOSAL SYSTEMS OR WELLS WERE LOCATED. SITE VICINITY MAP 16 CUTHBERTSON RDGRAY B Y R U M R D PINE OAK R D SKI TR AI L L N MI L L P O N D D R NTS 10 CB-221 CB-222 CB-248 CB-220 CB-223 CB-224 JB-225 CB-246 CB-247 DI-249 CB-245 CB-219 CB-218 DI-226 CB-234 CB-233 CB-235 CB-214 CB-215 CB-244 CB-236 DI-231 DI-217 JB-216 CB-213 CB-237 DI-230 CB-238 DCB-239 CB-232 DI-240 CB-211 CB-212 CB-228 CB-229 CB-210 CB-227 CB-209 DI-203 CB-207 CB-208 DI-202 CB-206 EW-20030" RCP15" RCP 1 5 " R C P24" RCP 2 4 " R C P 24" RCP2 4 " R C P 24" RC P 24" RCP24" RCP18" RCP18" RCP18" RCP 18" RCP18" RCP 18" RCP 15" RC P 15" R C P 15" RCP 15" R C P 15" RCP 15" RCP 15 " R C P 15" RCP1 5 " R C P 15" RCP 1 5 " R C P 15 " R C P 1 5 " R C P15" RCP15" RCP 1 5 " R C P 15" RCP15" RCP 15" RCP15" RCP 15" RCP15" RCP15" RCP15" RC P 15" RCP15" RCP15" RCP15" RCPPAD:567.60 11 PAD:567.60 12 PAD:569.10 13 PAD:569.10 14 PAD:569.10 15 PAD:569.50 16 PAD:569.50 17 PAD:569.50 18 PAD:569.50 19 PAD:569.50 20 PAD:567.70 21 PAD:567.70 22 PAD:567.70 23 PAD:566.99 24 PAD:566.80 1 PAD:555.50 2 PAD:555.50 3 PAD:557.00 4 PAD:557.00 5 PAD:559.40 6 PAD:560.90 7 PAD:560.90 8 PAD:562.40 9 PAD:562.40 89 PAD:555.50 90 PAD:555.50 91 PAD:556.50 92 PAD:556.50 93 PAD:556.50 80 PAD:547.00 81 PAD:547.00 82 PAD:548.50 83 PAD:550.00 84 PAD:550.00 85 PAD:555.80 86 PAD:555.80 87 PAD:557.80 88 PAD:557.80 46 PAD:562.90 45 PAD:562.90 44 PAD:564.40 43 PAD:564.40 42 PAD:567.30 41 PAD:567.30 40 PAD:568.80 39 PAD:568.80 38 PAD:569.30 37 PAD:569.30 36 PAD:569.30 25 PAD:565.60 26 PAD:565.60 27 PAD:564.60 28 PAD:564.60 29 PAD:563.10 30 PAD:563.10 31 PAD:561.10 32 PAD:561.10 33 PAD:560.10 34 PAD:560.10 35 PAD:560.10 47 PAD:557.70 48 PAD:557.70 49 PAD:556.70 50 PAD:556.70 51 PAD:554.70 52 PAD:554.70 79 PAD:543.00 78 PAD:543.00 77 PAD:541.50 76 PAD:541.50 75 PAD:540.00 74 PAD:540.00 73 PAD:538.00 72 PAD:538.00 71 PAD:537.00 70 PAD:537.00 69 PAD:536.00 PAD:538.50 54 PAD:539.50 53 PAD:539.50 CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-G1.dwg, 4/14/2021 10:35:11 AM, Bernard, AndrewThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-G1 C3.01 1"=40' GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft. ENCORE LANE (50' PUBLIC R/W) STREET ' A' (50' PU B L I C R / W ) ST R E E T ' B ' (5 0 ' P U B L I C R / W ) S T R E E T ' C ' ( 5 0 ' PU B L I C R /W ) CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R TREE PROTECTION NOTES: ·PROPERTY OWNERS ARE RESPONSIBLE FOR ENSURING THAT ALL EXISTING TREES SHOWN ON APPROVED PLANS AS BEING RETAINED TO MEET THE REQUIREMENTS OF THIS ARTICLE ARE PROTECTED DURING THE CONSTRUCTION PROCESS FROM REMOVAL, DESTRUCTION, OR INJURY. BEFORE ANY EXCAVATION TAKES PLACE ON THE SUBJECT SITE, A BARRIER MUST BE ERECTED AROUND THE DRIP LINE OF ALL SUCH TREES SUFFICIENT TO PUT ON NOTICE ALL CONSTRUCTION PERSONNEL THAT ANY DISTURBANCE OF THE AREA WITHIN THE DRIPLINE OF SUCH TREES IS PROHIBITED, EXCEPT AS EXPRESSLY APPROVED BY THE ADMINISTRATOR. REQUIRED TREE BARRIERS MUST BE SHOWN ON CONSTRUCTION PLANS ·FOR PRESERVED VEGETATION, MAINTENANCE SHALL BEGIN AT THE TIME THAT THE ROOT PROTECTION ZONES ARE ESTABLISHED (PRIOR TO ROUGH GRADING) AND SHALL CONTINUE INDEFINITELY. FOR PLANTED MATERIALS, MAINTENANCE SHALL BEGIN AT THE TIME OF PLANTING AND SHALL CONTINUE INDEFINITELY SITE VICINITY MAP 16 CUTHBERTSON RDGRAY B Y R U M R D PINE OAK R D SKI TR AI L L N MI L L P O N D D R NTS EXISTING CUTHBERTSON ROAD (PUBLIC R/W)SEE SHEET 3.02SEE SHEET C3.02 GRADING & STORM DRAINAGE PLAN - SOUTH GRADING LEGEND SITE LEGEND CB-213CB-211 CB-212 CB-228 CB-210 CB-227 CB-209 DI-203 CB-207 CB-208 DI-202 CB-206 CB-204 CB-205 DI-201 EW-20030" RCP15" RCP 1 5 " R C P 30" RCP 24" RCP 2 4 " R C P 24" RCP2 4 " R C P 24" RC P 24" RCP24" RCP15" RCP 15" R C P 15" RCP 15" RCP 15" RCP 80 PAD:547.00 81 PAD:547.00 82 PAD:548.50 83 48 PAD:557.70 49 PAD:556.70 50 PAD:556.70 51 PAD:554.70 52 DI-106 CB-103 JB-105 JB-104 CB-102 CB-101 EW-100 15" O-RING RCP 15" O-RING RCP 15" RCP15" RCP 15" RCP 15" R C P DI-303 JB-302 JB-301 EW-30015" RCP15" RCP 15" R C P 79 PAD:543.00 78 PAD:543.00 77 PAD:541.50 76 PAD:541.50 75 PAD:540.00 74 PAD:540.00 73 PAD:538.00 72 PAD:538.00 71 PAD:537.00 70 PAD:537.00 69 PAD:536.00 68 PAD:534.30 67 PAD:534.30 66 PAD:532.80 65 PAD:532.80 64 PAD:531.30 63 PAD:531.30 62 PAD:531.30 61 PAD:532.30 60 PAD:532.30 59 PAD:533.30 58 PAD:533.30 57 PAD:537.50 56 PAD:538.50 55 PAD:538.50 54 PAD:539.50 53 PAD:539.50 CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-G1.dwg, 4/14/2021 10:35:25 AM, Bernard, AndrewThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-G1 C3.02 1"=40' GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R GRADING LEGEND STORMWATER CONTROL MEASURE "A" (SEE C9.00 SHEETS) SITE LEGEND SITE VICINITY MAP 16 CUTHBERTSON RDGRAY B Y R U M R D PINE OAK R D SKI TR AI L L N MI L L P O N D D R NTS ST R E E T ' B ' (5 0 ' P U B L I C R / W ) STORMWATER CONTROL MEASURE "B" (SEE C9.00 SHEETS)SEE SHEET C3.01SEE SHEET C3.01 GRADING & STORM DRAINAGE PLAN - NORTH TREE PROTECTION NOTES: ·PROPERTY OWNERS ARE RESPONSIBLE FOR ENSURING THAT ALL EXISTING TREES SHOWN ON APPROVED PLANS AS BEING RETAINED TO MEET THE REQUIREMENTS OF THIS ARTICLE ARE PROTECTED DURING THE CONSTRUCTION PROCESS FROM REMOVAL, DESTRUCTION, OR INJURY. BEFORE ANY EXCAVATION TAKES PLACE ON THE SUBJECT SITE, A BARRIER MUST BE ERECTED AROUND THE DRIP LINE OF ALL SUCH TREES SUFFICIENT TO PUT ON NOTICE ALL CONSTRUCTION PERSONNEL THAT ANY DISTURBANCE OF THE AREA WITHIN THE DRIPLINE OF SUCH TREES IS PROHIBITED, EXCEPT AS EXPRESSLY APPROVED BY THE ADMINISTRATOR. REQUIRED TREE BARRIERS MUST BE SHOWN ON CONSTRUCTION PLANS ·FOR PRESERVED VEGETATION, MAINTENANCE SHALL BEGIN AT THE TIME THAT THE ROOT PROTECTION ZONES ARE ESTABLISHED (PRIOR TO ROUGH GRADING) AND SHALL CONTINUE INDEFINITELY. FOR PLANTED MATERIALS, MAINTENANCE SHALL BEGIN AT THE TIME OF PLANTING AND SHALL CONTINUE INDEFINITELY CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-G2.dwg, 4/14/2021 10:35:45 AM, Bernard, AndrewThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-G2 C3.03 N/A STORM DRAINAGE SCHEDULES SD-100 SD-200 SD-300 ENCORE GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft.Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-P1-Roads.dwg, 4/14/2021 10:36:11 AM, Bernard, AndrewCLIENT REVISIONS N0.DATE PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 The John R. McAdams Company, Inc. www.mcadamsco.com phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 3430 Toringdon Way Suite 110 Charlotte, NC 28277 PLAN INFORMATION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704.972.4205 FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION PLAN AND PROFILE 1"=40'/1"=4' DWH19010-P1-Roads CUTHBERTSON TOWNHOMES CONSTRUCTION DRAWINGS 2219 CUTHBERTSON ROAD WAXHAW, NORTH CAROLINA, 28173 C5.00 ENCORE LANE STA. 10+00 THRU STA. 12+08.51 10 11 9 8 42 41 43 44 45 46 ENCORE LANE (50' PUBLIC R/W)STREET 'A'(50' PUBLIC R/W)EXISTINGCUTHBERTSON ROAD(PUBLIC R/W) STREET A GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft.Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-P1-Roads.dwg, 4/14/2021 10:36:27 AM, Bernard, AndrewCLIENT REVISIONS N0.DATE PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 The John R. McAdams Company, Inc. www.mcadamsco.com phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 3430 Toringdon Way Suite 110 Charlotte, NC 28277 PLAN INFORMATION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704.972.4205 FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION PLAN AND PROFILE 1"=40'/1"=4' DWH19010-P1-Roads CUTHBERTSON TOWNHOMES CONSTRUCTION DRAWINGS 2219 CUTHBERTSON ROAD WAXHAW, NORTH CAROLINA, 28173 C5.01 STREET 'A' STA. 10+00 THRU STA. 19+93.33ENCORE LANE(50' PUBLIC R/W)STREET 'A' (50' PUBLIC R / W ) EXISTINGCUTHBERT S O N R O A D (PUBLIC R/ W )STREET 'B'(50' PUBLIC R/W)STREET 'C ' (50 ' PUB L IC R /W ) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 36 373839404142 43444546 87 8889 90 91 92 93 STREET B GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft.Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-P1-Roads.dwg, 4/14/2021 10:36:43 AM, Bernard, AndrewCLIENT REVISIONS N0.DATE PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 The John R. McAdams Company, Inc. www.mcadamsco.com phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 3430 Toringdon Way Suite 110 Charlotte, NC 28277 PLAN INFORMATION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704.972.4205 FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION PLAN AND PROFILE 1"=40'/1"=4' DWH19010-P1-Roads CUTHBERTSON TOWNHOMES CONSTRUCTION DRAWINGS 2219 CUTHBERTSON ROAD WAXHAW, NORTH CAROLINA, 28173 C5.02 STREET 'B' STA. 10+00 THRU STA. 17+50STREET 'A'(50' PUBLIC R/W) STREET 'B' (50' PUBLI C R / W )STREET 'C'(50' PUBLIC R/W)88 87 86 85 84 83 82 81 80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 64 58 59 5756555453 52 46 45 44 43 STREET B GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft.Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-P1-Roads.dwg, 4/14/2021 10:36:57 AM, Bernard, AndrewCLIENT REVISIONS N0.DATE PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 The John R. McAdams Company, Inc. www.mcadamsco.com phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 3430 Toringdon Way Suite 110 Charlotte, NC 28277 PLAN INFORMATION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704.972.4205 FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION PLAN AND PROFILE 1"=40'/1"=4' DWH19010-P1-Roads CUTHBERTSON TOWNHOMES CONSTRUCTION DRAWINGS 2219 CUTHBERTSON ROAD WAXHAW, NORTH CAROLINA, 28173 C5.03 STREET 'B' STA. 17+50 THRU STA. 25+40.96 STREET 'B' (50' PUBLIC R/W) 62616059 64 636566 STREET C GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft.Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-P1-Roads.dwg, 4/14/2021 10:37:13 AM, Bernard, AndrewCLIENT REVISIONS N0.DATE PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 The John R. McAdams Company, Inc. www.mcadamsco.com phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 3430 Toringdon Way Suite 110 Charlotte, NC 28277 PLAN INFORMATION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704.972.4205 FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION PLAN AND PROFILE 1"=40'/1"=4' DWH19010-P1-Roads CUTHBERTSON TOWNHOMES CONSTRUCTION DRAWINGS 2219 CUTHBERTSON ROAD WAXHAW, NORTH CAROLINA, 28173 C5.04 STREET 'C' STA. 10+00 THRU STA. 15+98.93STREET 'A'(50' PUBLIC R/W) STREET 'C' (50' PUBLI C R / W ) 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 41 40 39 38 37 36 47 48 49 50 51 52 STRE E T ' D ' (50' P U B L I C R / W ) C5.05 GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft.Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-P2-LOS.dwg, 4/14/2021 10:37:36 AM, Bernard, AndrewCLIENT REVISIONS N0.DATE PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 The John R. McAdams Company, Inc. www.mcadamsco.com phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 3430 Toringdon Way Suite 110 Charlotte, NC 28277 PLAN INFORMATION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704.972.4205 FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION PLAN AND PROFILE 1"=40'/1"=4' DWH19010-P2-LOS CUTHBERTSON TOWNHOMES CONSTRUCTION DRAWINGS 2219 CUTHBERTSON ROAD WAXHAW, NORTH CAROLINA, 28173 C5.05 LINGE OF SIGHT INTERSECTION OF ENCORE LANE AND CUTHBERTSON RDENCORE LANE(50' PUBLIC R/W)EXISTING CUTHBERTSON ROAD (PUBLIC R/W) INTERSECTION OF ENCORE LANE AND CUTHBERTSON RD (POSTED SPEED LIMIT: 45 MPH) C5.06 GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft.Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-P2-LOS.dwg, 4/14/2021 10:37:49 AM, Bernard, AndrewCLIENT REVISIONS N0.DATE PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 The John R. McAdams Company, Inc. www.mcadamsco.com phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 3430 Toringdon Way Suite 110 Charlotte, NC 28277 PLAN INFORMATION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704.972.4205 FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION PLAN AND PROFILE 1"=40'/1"=4' DWH19010-P2-LOS CUTHBERTSON TOWNHOMES CONSTRUCTION DRAWINGS 2219 CUTHBERTSON ROAD WAXHAW, NORTH CAROLINA, 28173 C5.06 LINGE OF SIGHT INTERSECTION OF STREET 'A' AND CUTHBERTSON RDSTREET 'A'(50' PUBLIC R/W)EXISTING CUTHBERTSON ROAD (PUBLIC R/W) INTERSECTION OF STREET 'A' AND CUTHBERTSON RD (POSTED SPEED LIMIT: 45 MPH) C5.07 GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft.Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-P2-LOS.dwg, 4/14/2021 10:37:59 AM, Bernard, AndrewCLIENT REVISIONS N0.DATE PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 The John R. McAdams Company, Inc. www.mcadamsco.com phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 3430 Toringdon Way Suite 110 Charlotte, NC 28277 PLAN INFORMATION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704.972.4205 FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION PLAN AND PROFILE 1"=40'/1"=4' DWH19010-P2-LOS CUTHBERTSON TOWNHOMES CONSTRUCTION DRAWINGS 2219 CUTHBERTSON ROAD WAXHAW, NORTH CAROLINA, 28173 C5.07 LINGE OF SIGHT INTERSECTION OF ENCORE LANE AND STREET 'A' INTERSECTION OF ENCORE LANE AND STREET 'A' (POSTED SPEED LIMIT: 25 MPH)ENCORE LANE(50' PUBLIC R/W)STREET 'A' (50' PUBLIC R/W) C5.08 GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft.Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-P2-LOS.dwg, 4/14/2021 10:38:08 AM, Bernard, AndrewCLIENT REVISIONS N0.DATE PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 The John R. McAdams Company, Inc. www.mcadamsco.com phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 3430 Toringdon Way Suite 110 Charlotte, NC 28277 PLAN INFORMATION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704.972.4205 FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION PLAN AND PROFILE 1"=40'/1"=4' DWH19010-P2-LOS CUTHBERTSON TOWNHOMES CONSTRUCTION DRAWINGS 2219 CUTHBERTSON ROAD WAXHAW, NORTH CAROLINA, 28173 C5.08 LINGE OF SIGHT INTERSECTION OF STREET 'B' AND STREET 'A' INTERSECTION OF STREET 'B' AND STREET 'A' (POSTED SPEED LIMIT: 25 MPH)STREET 'B'(50' PUBLIC R/W)STREET 'A' (50' PUBLIC R/W) C5.09 GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft.Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-P2-LOS.dwg, 4/14/2021 10:38:18 AM, Bernard, AndrewCLIENT REVISIONS N0.DATE PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 The John R. McAdams Company, Inc. www.mcadamsco.com phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 3430 Toringdon Way Suite 110 Charlotte, NC 28277 PLAN INFORMATION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704.972.4205 FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION PLAN AND PROFILE 1"=40'/1"=4' DWH19010-P2-LOS CUTHBERTSON TOWNHOMES CONSTRUCTION DRAWINGS 2219 CUTHBERTSON ROAD WAXHAW, NORTH CAROLINA, 28173 C5.09 LINGE OF SIGHT INTERSECTION OF STREET 'C' AND STREET 'A' INTERSECTION OF STREET 'C' AND STREET 'A' (POSTED SPEED LIMIT: 25 MPH) S T R E E T ' C ' ( 5 0 ' P U B L I C R /W ) STREET ' A' (50' PU B LI C R / W ) C5.10 GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft.Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-P2-LOS.dwg, 4/14/2021 10:38:29 AM, Bernard, AndrewCLIENT REVISIONS N0.DATE PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 The John R. McAdams Company, Inc. www.mcadamsco.com phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 3430 Toringdon Way Suite 110 Charlotte, NC 28277 PLAN INFORMATION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704.972.4205 FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION PLAN AND PROFILE 1"=40'/1"=4' DWH19010-P2-LOS CUTHBERTSON TOWNHOMES CONSTRUCTION DRAWINGS 2219 CUTHBERTSON ROAD WAXHAW, NORTH CAROLINA, 28173 C5.10 LINGE OF SIGHT INTERSECTION OF STREET 'C' AND STREET 'B' INTERSECTION OF STREET 'C' AND STREET 'B' (POSTED SPEED LIMIT: 25 MPH)STREET 'C'(50' PUBLIC R/W)STREET 'D' (50' PUBLIC R/W) CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-OAEC1.dwg, 4/14/2021 10:38:50 AM, Bernard, AndrewThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-OAEC1 C6.00 1"=60' OVERALL EROSION & GRAPHIC SCALE 0 30 60 120 1 inch = 60 ft. EXISTING CUTHBERTSON ROAD (PUBLIC R/W) CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R SEDIMENT CONTROL PLAN DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD, SUITE 275 CHARLOTTE, NC 28277 ATTN: SHANNON BOLING SBOLING@DWHOMES.COM 704. 972. 4205 WALTER ROBERT PFISTER & CHRISTINE L. PFISTER ATTN: SHANNON BOLING SBOLING@DWHOMES.COM 704. 972. 4205 THE JOHN R. MCADAMS COMPANY 3430 TORINGDON WAY, SUITE 110 CHARLOTTE, NC 28277 704.527.0800 ATTN:MARC VAN DINE VANDINE@MCADAMSCO.COM 704.537.0800 DEVELOPER/APPLICANT: PROPERTY OWNER: ENGINEER OF RECORD: ENVIRONMENTAL HEALTH LAND USE NOTE: ·ANY WELLS AND/OR ON-SITE WASTEWATER DISPOSAL SYSTEMS DISCOVERED DURING THE SITE DEVELOPMENT PROCESS WILL BE ABANDONED IN ACCORDANCE WITH APPLICABLE NORTH CAROLINA LAWS AND RULES. ·NO ON-SITE WASTEWATER DISPOSAL SYSTEMS OR WELLS WERE LOCATED. SITE VICINITY MAP 16 CUTHBERTSON RDGRAY B Y R U M R D PINE OAK R D SKI TR AI L L N MI L L P O N D D R NTS STAGE I SB-A DA=4.50 AC SB-B DA=3.32 AC SB-C DA=1.00 AC SB-D DA=1.60 AC SB-E DA=0.50 AC SB-F DA=1.39 AC SB-G DA=1.85 AC SB-H DA=10.00 AC DRAINAGE AREA NOTE: ALL SKIMMER BASINS ARE SIZED FOR THE MAXIMUM DRAINAGE AREA THAT WILL DRAIN TO THE BASIN DURING CONSTRUCTION SEE SHEET C0.00 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE AND UTILITY NOTES EROSION CONTROL LEGEND GRADING LEGEND SITE LEGEND CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-EC1.dwg, 4/14/2021 10:39:15 AM, Bernard, AndrewThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-EC1 1"=40' GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R SITE VICINITY MAP 16 CUTHBERTSON RDGRAY B Y R U M R D PINE OAK R D SKI TR AI L L N MI L L P O N D D R NTS EXISTING CUTHBERTSON ROAD (PUBLIC R/W)SEE SHEET C6.02SEE SHEET C6.02 SITE LEGEND SEE SHEET C0.00 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE AND UTILITY NOTES C6.01 OVERALL EROSION & SEDIMENT CONTROL PLAN STAGE I- S GRADING LEGEND EROSION CONTROL LEGEND SB-A (SEE SUMMARY TABLE ON SHEET C6.10) SB-B (SEE SUMMARY TABLE ON SHEET C6.10) SB-C (SEE SUMMARY TABLE ON SHEET C6.10) SB-D (SEE SUMMARY TABLE ON SHEET C6.10) CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-EC1.dwg, 4/14/2021 10:39:28 AM, Bernard, AndrewThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-EC1 1"=40' GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R SITE VICINITY MAP 16 CUTHBERTSON RDGRAY B Y R U M R D PINE OAK R D SKI TR AI L L N MI L L P O N D D R NTS SEE SHEET C6.01SEE SHEET C6.01 C6.02 OVERALL EROSION & SEDIMENT CONTROL PLAN STAGE I - N SITE LEGEND SEE SHEET C0.00 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE AND UTILITY NOTES GRADING LEGEND EROSION CONTROL LEGEND SB-E (SEE SUMMARY TABLE ON SHEET C6.10) SB-F (SEE SUMMARY TABLE ON SHEET C6.10) SB-G (SEE SUMMARY TABLE ON SHEET C6.10) SB-H (SEE SUMMARY TABLE ON SHEET C6.10) CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-OAEC2.dwg, 4/14/2021 10:39:50 AM, Bernard, AndrewThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-OAEC2 C6.03 1"=60' OVERALL EROSION & GRAPHIC SCALE 0 30 60 120 1 inch = 60 ft. EXISTING CUTHBERTSON ROAD (PUBLIC R/W) CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R SEDIMENT CONTROL PLAN DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD, SUITE 275 CHARLOTTE, NC 28277 ATTN: SHANNON BOLING SBOLING@DWHOMES.COM 704. 972. 4205 WALTER ROBERT PFISTER & CHRISTINE L. PFISTER ATTN: SHANNON BOLING SBOLING@DWHOMES.COM 704. 972. 4205 THE JOHN R. MCADAMS COMPANY 3430 TORINGDON WAY, SUITE 110 CHARLOTTE, NC 28277 704.527.0800 ATTN:MARC VAN DINE VANDINE@MCADAMSCO.COM 704.537.0800 DEVELOPER/APPLICANT: PROPERTY OWNER: ENGINEER OF RECORD: ENVIRONMENTAL HEALTH LAND USE NOTE: ·ANY WELLS AND/OR ON-SITE WASTEWATER DISPOSAL SYSTEMS DISCOVERED DURING THE SITE DEVELOPMENT PROCESS WILL BE ABANDONED IN ACCORDANCE WITH APPLICABLE NORTH CAROLINA LAWS AND RULES. ·NO ON-SITE WASTEWATER DISPOSAL SYSTEMS OR WELLS WERE LOCATED. SITE VICINITY MAP 16 CUTHBERTSON RDGRAY B Y R U M R D PINE OAK R D SKI TR AI L L N MI L L P O N D D R NTS STAGE II EROSION CONTROL LEGEND GRADING LEGEND SB-A SB-B SB-C SB-D SB-E SB-F SB-G SB-H SITE LEGEND SEE SHEET C0.00 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE AND UTILITY NOTES CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-EC2.dwg, 4/14/2021 10:40:15 AM, Bernard, AndrewThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-EC2 1"=40' GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R SITE VICINITY MAP 16 CUTHBERTSON RDGRAY B Y R U M R D PINE OAK R D SKI TR AI L L N MI L L P O N D D R NTS EXISTING CUTHBERTSON ROAD (PUBLIC R/W)SEE SHEET C6.05SEE SHEET C6.05 C6.04 OVERALL EROSION & SEDIMENT CONTROL PLAN STAGE II - S SB-A SB-B SB-C SB-D SITE LEGEND SEE SHEET C0.00 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE AND UTILITY NOTES GRADING LEGEND EROSION CONTROL LEGEND CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-EC2.dwg, 4/14/2021 10:40:28 AM, Bernard, AndrewThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-EC2 1"=40' GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R SITE VICINITY MAP 16 CUTHBERTSON RDGRAY B Y R U M R D PINE OAK R D SKI TR AI L L N MI L L P O N D D R NTS SEE SHEET C6.04SEE SHEET C6.04 C6.05 OVERALL EROSION & SEDIMENT CONTROL PLAN STAGE II - N SB-E SB-F SB-G SB-H SITE LEGEND SEE SHEET C0.00 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE AND UTILITY NOTES GRADING LEGEND EROSION CONTROL LEGEND CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-OAEC3.dwg, 4/14/2021 10:40:51 AM, Bernard, AndrewThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-OAEC3 C6.06 1"=60' OVERALL EROSION & GRAPHIC SCALE 0 30 60 120 1 inch = 60 ft. EXISTING CUTHBERTSON ROAD (PUBLIC R/W) CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R SEDIMENT CONTROL PLAN DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD, SUITE 275 CHARLOTTE, NC 28277 ATTN: SHANNON BOLING SBOLING@DWHOMES.COM 704. 972. 4205 WALTER ROBERT PFISTER & CHRISTINE L. PFISTER ATTN: SHANNON BOLING SBOLING@DWHOMES.COM 704. 972. 4205 THE JOHN R. MCADAMS COMPANY 3430 TORINGDON WAY, SUITE 110 CHARLOTTE, NC 28277 704.527.0800 ATTN:MARC VAN DINE VANDINE@MCADAMSCO.COM 704.537.0800 DEVELOPER/APPLICANT: PROPERTY OWNER: ENGINEER OF RECORD: ENVIRONMENTAL HEALTH LAND USE NOTE: ·ANY WELLS AND/OR ON-SITE WASTEWATER DISPOSAL SYSTEMS DISCOVERED DURING THE SITE DEVELOPMENT PROCESS WILL BE ABANDONED IN ACCORDANCE WITH APPLICABLE NORTH CAROLINA LAWS AND RULES. ·NO ON-SITE WASTEWATER DISPOSAL SYSTEMS OR WELLS WERE LOCATED. SITE VICINITY MAP 16 CUTHBERTSON RDGRAY B Y R U M R D PINE OAK R D SKI TR AI L L N MI L L P O N D D R NTS STAGE III STORMWATER CONTROL MEASURE "B" (SEE C9.00 SHEETS) STORMWATER CONTROL MEASURE "A" (SEE C9.00 SHEETS) SEE SHEET C0.00 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE AND UTILITY NOTES GRADING LEGEND SITE LEGEND EROSION CONTROL LEGEND CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-EC3.dwg, 4/14/2021 10:41:16 AM, Bernard, AndrewThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-EC3 1"=40' GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R SITE VICINITY MAP 16 CUTHBERTSON RDGRAY B Y R U M R D PINE OAK R D SKI TR AI L L N MI L L P O N D D R NTS EXISTING CUTHBERTSON ROAD (PUBLIC R/W)SEE SHEET C6.08SEE SHEET C6.08 GRADING LEGEND SITE LEGEND SEE SHEET C0.00 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE AND UTILITY NOTES C6.07 OVERALL EROSION & SEDIMENT CONTROL PLAN STAGE III - S EROSION CONTROL LEGEND CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-EC3.dwg, 4/14/2021 10:41:28 AM, Bernard, AndrewThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-EC3 1"=40' GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R STORMWATER CONTROL MEASURE "A" (SEE C9.00 SHEETS) SITE VICINITY MAP 16 CUTHBERTSON RDGRAY B Y R U M R D PINE OAK R D SKI TR AI L L N MI L L P O N D D R NTS STORMWATER CONTROL MEASURE "B" (SEE C9.00 SHEETS)SEE SHEET C6.07SEE SHEET C6.07 C6.08 OVERALL EROSION & SEDIMENT CONTROL PLAN STAGE III - N GRADING LEGEND SITE LEGEND SEE SHEET C0.00 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE AND UTILITY NOTES EROSION CONTROL LEGEND CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-EC4.dwg, 4/14/2021 10:41:51 AM, Bernard, AndrewThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-EC4 C6.09 N / A EROSION & SEDIMENTCONTROL DETAILS CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-EC4.dwg, 4/14/2021 10:42:01 AM, Bernard, AndrewThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-EC4 C6.10 N / A EROSION & SEDIMENTCONTROL DETAILS A B C D E F G 4.50 3.32 1.00 1.60 0.50 1.39 1.85 4.50 3.32 1.00 1.60 0.50 1.39 1.85 20.5 15.1 4.5 7.3 2.3 6.3 8.4 8100 5976 1800 2880 900 2502 3330 12864 9052 3142 3928 1246 4213 5523 6650 4910 1480 2360 740 2050 2730 7268 5088 1912 2485 902 2656 3207 1 1 1 1 1 1 1 2 2 2 2 2 2 2 3.5 3.5 3.5 3.5 3.5 4.0 3.5 20 15 10 10 10 10 10 1.5 1.5 1.5 1.5 1.5 2.0 1.5 5 5 5 5 5 5 5 2 2 2 2 2 2 2 1.75 1.75 1 1.25 0.75 1 1.25 G 10.0 10.0 45.4 18000 20336 14780 14898 1 2 4.0 30 2.0 10 2.5 2.5 CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-EC4.dwg, 4/14/2021 10:42:16 AM, Bernard, AndrewThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-EC4 C6.11 N / A EROSION & SEDIMENTCONTROL DETAILS CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-D1.dwg, 4/14/2021 10:42:42 AM, Bernard, AndrewThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-D1 C8.00 N / A SITE DETAILS CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-D1.dwg, 4/14/2021 10:42:52 AM, Bernard, AndrewThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-D1 C8.01 N / A STORM DRAINAGE DETAILS CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-D1.dwg, 4/14/2021 10:43:01 AM, Bernard, AndrewThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-D1 C8.02 N / A STORM DRAINAGE DETAILS CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-SWA.dwg, 4/14/2021 10:43:29 AM, Bernard, AndrewThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-SWA N / A C9.01 MEASURE "A" DETAILS STORMWATER CONTROL NOTES: 1. REMOVED TOPSOIL SHALL BE STOCKPILED FOR USE IN PLANTING (SEEDING) THE DAM EMBANKMENT ONCE FINAL GRADES (AS SHOWN ON THE GRADING PLAN) HAVE BEEN ESTABLISHED WITH COMPACTED FILL. PRIOR TO TOPSOIL INSTALLATION, THE CONTRACTOR SHALL SCARIFY THE TOP 2- TO 3-INCHES OF THE BERMN SECTION TO PROMOTE BONDING OF THE TOPSOIL WITH THE COMPACTED FILL. THE TOPSOIL DEPTH SHALL RANGE FROM 3- TO 4-INCHES ON THE DAM EMBANKMENT. PERMANENT DAM CROSS SECTION N.T.S. N.T.S. RISER JOINT CONNECTION DETAIL N.T.S. PERMANENT OUTLET STRUCTURE DETAILS NOTES: 1. CONCRETE ANTI-FLOTATION BLOCK TO BE PROVIDED WITH MINIMUM TEMPERATURE AND SHRINKAGE STEEL REINFORCEMENT. 2. TRASH RACKS NOT SHOWN FOR CLARITY. 3. THE NUMBER OF GUIDES FOR THE VALVE STEM SHALL BE DETERMINED IN THE FIELD BY THE CONTRACTOR. THE VALVE STEM MUST BE OPERABLE FROM THE TOP OF THE RISER VIA THE HANDWHEEL WITH AN INSIGNIFICANT AMOUNT OF PLAY IN THE VALVE STEM. 4. CONTRACTOR SHALL PROVIDE A JOINT IN THE OUTLET BARREL NO MORE THAN 5-FT FROM THE RISER. WET POND CROSS SECTION RISER TRASH RACK DETAIL N.T.S. 36" CONCRETE COLLAR DETAIL N.T.S. NOTES: 1.ALL REBAR TO BE #4 REBAR. 2.ALL REBAR AND ANGLES TO BE HOT-DIPPED GALVANIZED AND BE PROVIDED WITH AN EPOXY COATING. 3.THE HOT-DIPPED, GALVANIZED 2"x2"x1/4" ANGLES SHALL BE WELDED TO THE REBAR TRASH RACK. ONCE WELDED, THE ENTIRE ASSEMBLY SHALL BE PLACED ONTO THE RISER WITH ANGLES SITTING DIRECTLY ON TOP OF RISER. 4.CONTRACTOR SHALL ANCHOR THE TRASH RACK TO MANHOLE WALL WITH FOUR 4"x1/4" CONCRETE ANCHOR BOLTS THROUGH ANGLES. 5.CONTRACTOR SHALL OMIT OR ADJUST REBAR AS NECESSARY TO ALLOW FOR CONCRETE COLLAR. 6.ACCESS HATCH SHALL ALIGN WITH STEPS IN RISER. NOTES: 1.ALL REBAR TO BE #4 REBAR. 2.WRAP OUTSIDE OF PIPE WITH VOLCLAY WATERSTOP-RX® 101 (OR PRE-APPROVED EQUIVALENT) AT THE FACE OF THE PRECAST STRUCTURE WALL. PROVIDE 6" OVER LAP ON THE BOTTOM OF THE PIPE. FRONT VIEW SIDE VIEW CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-SWA.dwg, 4/14/2021 10:43:36 AM, Bernard, AndrewThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-SWA N / A C9.02 STORMWATER CONTROL MEASURE "A" DETAILS 6"Ø EMERGENCY DIP DRAIN TRASHRACK DETAILS N.T.S. N.T.S. OUTLET BARREL VELOCITY DISSIPATOR PLAN SECTION A-A NOTES: 1.A FILTER BLANKET IS TO BE INSTALLED BETWEEN THE RIPRAP AND SOIL FOUNDATION. THE FILTER BLANKET WILL CONSIST OF A MINIMUM 4" THICK LAYER OF STONE (NCDOT #57) UNDERLAIN WITH MIRAFI FILTER WEAVE 700 OR APPROVED EQUIVALENT N.T.S. SIPHON OUTLET DETAIL N.T.S. RISER BARREL/CRADLE CONNECTION DETAIL TOP VIEW SIDE VIEW SPILLWAY FILTER DETAIL N.T.S. N.T.S. 36" CONCRETE CRADLE DETAIL BARREL PIPE FLOWABLE FILL CRADLE CONSTRUCTION SEQUENCE 1. CONSTRUCT FORMWORK FOR FLOWABLE FILL CRADLE ON EXISTING GRADE. 2. EXCAVATE TRENCH FOR CRADLE AND BARREL PER DIMENSIONS ON DRAWINGS. 3. PLACE BARREL PIPE ON CONCRETE BLOCKS TO GRADE. CONTRACTOR SHALL WRAP JOINTS WITH 2-FT WIDE STRIPS OF FABRIC AT THIS STEP. 4. PLACE FLOWABLE FILL FOR CRADLE FOR EACH SECTION FROM ONE SIDE OF THE TRENCH. ALLOW FLOWABLE FILL TO FILL ENTIRE AREA UNDER PIPE AND PIPE HAUNCHES AS TO LEAVE NO VOIDS UNDER THE PIPE BEFORE PLACING FLOWABLE FILL ON THE OPPOSITE SIDE OF THE TRENCH. PLACE ENTIRE CRADLE AS ONE LIFT (VERTICALLY) PER DRAWINGS. 5. FLOWABLE FILL CRADLE MAY BE ELIMINATED PER RECOMMENDATION FROM THE ON-SITE GEOTECHNICAL ENGINEER. ANY DEVIATION FROM THIS DETAIL SHALL BE SUBMITTED TO AND REVIEWED BY THE DESIGN ENGINEER PRIOR TO IMPLEMENTATION. IF THE CRADLE IS ELIMINATED, THEN A LETTER FROM AN NC PE CERTIFYING THAT ALL SOIL MATERIAL UNDER, AROUND, AND ABOVE THE BARREL PIPE MEETS THE BERM MATERIAL SPECIFICATIONS STATED ON SHEET C9.00 IS REQUIRED. 6. ALLOW CRADLE TO CURE FOR A MINIMUM OF 7 DAYS BEFORE ANY VIBRATING COMPACTION EQUIPMENT IS USED IN THE VICINITY OF THE BARREL PIPE. 7. TRENCH TO BE BACKFILLED IN 5" LIFTS WHEN COMPACTION IS BY HAND. BACKFILL IS IN 8" LIFTS WHEN CONDUCTED BY MACHINE. MINIMUM OF 2 FEET COVER MUST BE PRESENT ON 24"Ø RCP BEFORE DRIVING OVER WITH HEAVY EQUIPMENT. N / A C9.101 STORMWATER CONTROL MEASURE "B" DETAILS PERMANENT DAM CROSS SECTION A-A N.T.S. 15"Ø RCP INV. OUT EL. = 516.15 NOTES: 1. REMOVED TOPSOIL SHALL BE STOCKPILED FOR USE IN PLANTING (SEEDING) THE DAM EMBANKMENT ONCE FINAL GRADES (AS SHOWN ON THE GRADING PLAN) HAVE BEEN ESTABLISHED WITH COMPACTED FILL. PRIOR TO TOPSOIL INSTALLATION, THE CONTRACTOR SHALL SCARIFY THE TOP 2- TO 3-INCHES OF THE BERMN SECTION TO PROMOTE BONDING OF THE TOPSOIL WITH THE COMPACTED FILL. THE TOPSOIL DEPTH SHALL RANGE FROM 3- TO 4-INCHES ON THE DAM EMBANKMENT. CONCRETE ANTI-FLOTATION BLOCK CONTRACTOR SHALL FORM INVERT OF RISER STRUCTURE TO DRAIN POSITIVELY TO INVERT OF OUTLET BARREL USING NON-SHRINK GROUT A DOUBLE LAYER OF NON-WOVEN GEOTEXTILE FABRIC SHALL BE PLACED AROUND EACH JOINT OF 15"Ø O-RING RCP BARREL IN 2' WIDE STRIPS CENTERED ON JOINT. 32 LF CLASS III 15"Ø O-RING RCP (ASTM C76-LATEST) @ 2.03% FLOW TOP OF DAM EL. = 523.00 WQV STORM EL. = 520.54 15"Ø CLASS III O-RING RCP INV. = 516.15 APPROXIMATE LOCATION OF EXISTING GROUND 100-YEAR STORM EL. = 521.24 TRASH RACK (SEE DETAIL SHEET C9.102) 1" THICK JOINT FILLER MATERIAL NOTE: PRIOR TO CONSTRUCTION, THE ONSITE GEOTECHNICAL ENGINEER SHALL VERIFY THE FILTRATION AND PERMEABILITY ASPECTS OF THE PROPOSED SAND FILTER MATERIALS. SPECIAL ATTENTION SHALL BE PAID TO PREVENT MIGRATION OF FINER SOIL PARTICLES THROUGH UNDERLYING GRAVEL LAYERS. MATERIAL SPECIFICATIONS/ TEST METHOD SIZE NOTES SAND CLEAN AASHTO-M-6 OR ASTM-C-33 CONCRETE SAND 0.02" TO 0.04"SAND SUBSTITUTIONS SUCH AS DIABASE AND GRAYSTONE #10 ARE NOT ACCEPTABLE. NO CALCIUM CARBONATE OR DOLOMITIC SAND SUBSTITUTIONS ARE ACCEPTABLE. NO "ROCK DUST" CAN BE USED FOR SAND. UNDERDRAIN GRAVEL AASHTO-M-43 0.375" TO 0.75" GEOTEXTILE FILTER FABRIC ASTM-D-4833 (PUNCTURE STRENGTH-125LB) ASTM-D-4632 (TENSILE STRENGTH-300LB) 0.08" THICK EQUIVALENT OPENING SIZE OF #80 SIEVE MUST MAINTAIN 125 GPM PER SQ. FT. FLOW RATE. GEOTEX 117F - WOVEN MONOFILAMENT GEOTEXTILE OR APPROVED EQUIVALENT. UNDERDRAIN PIPING F 758, TYPE PS 25 OR AASHTO-M-252 6" SCHEDULE 40 OR SDR 35 SMOOTH WALL PVC 3/8" PERFORATIONS @ 6" ON CENTER, 4 HOLES PER ROW. MINIMUM OF 4" OF GRAVEL OVER PIPES EACH OBSERVATION WELL/CLEANOUT SHALL INCLUDE THE FOLLOWING: 1.FOR AN UNDERGROUND FLUSH MOUNTED OBSERVATION WELL/CLEANOUT, PROVIDE A TUBE MADE OF NON-CORROSIVE MATERIAL, SCHEDULE 40 OR EQUAL, AT LEAST THREE FEET LONG WITH AN INSIDE DIAMETER OF AT LEAST 6 INCHES. 2.THE TUBE SHALL HAVE A FACTORY ATTACHED CAST IRON OR HIGH IMPACT PLASTIC COLLAR WITH RIBS TO PREVENT ROTATION WHEN REMOVING SCREW TOP LID. THE SCREW TOP LID SHALL BE CAST IRON OR HIGH IMPACT PLASTIC THAT WILL WITHSTAND ULTRAVIOLET RAYS. *ABOVE DETAIL PROVIDED AS SCHEMATIC SCREW TOP P.V.C. WELL CAP ONLY N.T.S. EL. 520.54 EL. 520.00 EL. VARIES 1" MIN. EL. 519.00 19" MIN 12" 7" MIN 6" PONDING DEPTH SAND FILTER MATERIAL SPECIFICATIONS SAND FILTER CROSS SECTION CLEANOUT DETAIL N.T.S.N.T.S. 6"Ø PERFORATED SCHEDULE 40 OR SDR 35 SMOOTH WALL PVC UNDERDRAIN PIPE (PER AASHTO M252)WOVEN GEOTEXTILE FILTER FABRIC 6"Ø SOLID SCHEDULE 40 OR SDR 35 SMOOTH WALL PVC PIPE SEAL GASKET PANELLA TYPE CLEANOUT WITH COUNTERSUNK HEAD SCREW TOP LID* FINISHED GRADE SAND MEDIA NON-WOVEN GEOTEXTILE FILTER FABRIC WASHED #57 STONE OR APPROVED EQUIVALENT 1 2 1 2 FLOW TO OUTLET STRUCTURE 6" MIN #57 WASHED STONE TOP OF SAND MEDIA = 520.00 1% MINIMUM SLOPE 2 FT SAND FILTER PROFILE VIEW N.T.S. RIPRAP BERM NCDOT CLASS 'B' RIPRAP D50 = 8" PROPOSED GRADE THE UNDERDRAIN COLLECTION SYSTEM SHOULD BE EQUIPPED WITH 6"Ø MINIMUM PERFORATED SCHEDULE 40 OR SDR 35 SMOOTH WALL PVC. PERFORATIONS SHALL BE PER AASHTO M278 FOR PVC PIPE, AASHTO M252 DOUBLE WALL HDPE PIPE, OR BE 3 8-INCH IN DIAMETER SPACED 3 INCHES ON CENTER ALONG 2 LONGITUDINAL ROWS THAT ARE SPACED 90° APART. THE PIPES SHALL HAVE A MINIMUM SLOPE OF 0.50% AND A MAXIMUM SPACING OF 10 FEET ON CENTER. TOP OF RIPRAP BERM ELEV = 522.00 SAND-BASED BERMUDA SOD TO BE INSTALLED IN THE PRETREATMENT AREA FILTER BLANKET TO BE INSTALLED BETWEEN THE RIP RAP AND SOIL FOUNDATION. THE FILTER BLANKET WILL CONSIST OF A MINIMUM 4" THICK LAYER OF STONE (#57) UNDERLAIN WITH MIRAFI FILTER WEAVE 700 OR APPROVED EQUIVALENT 6"Ø SOLID WALL PVC CLEANOUTS (TYP.) SHALL HAVE A SECURELY FASTENED WATERPROOF CAP AND BE A MINIMUM OF 3" ABOVE THE SAND LAYER. THE CLEANOUTS SHALL BE CONNECTED TO THE 6"Ø PERFORATED SCHEDULE 40 OR SDR 35 SMOOTH WALL PVC UNDERDRAIN PIPES WITH A WYE-SECTION. FILTER MEDIA (SEE CROSS SECTION AND SPECIFICATIONS PROVIDED) 6"Ø @ 0.50% PERFORATED SCHEDULE 40 OR SDR 35 SMOOTH WALL PVC THE TOP OF THE SAND FILTER MEDIA MUST BE PROTECTED. USE A FILTER FABRIC WITH A LAYER OF WASHED #2 STONE ON TOP. FILTER FABRIC TOP OF MEDIA = 520.00 THE TOP OF THE SAND FILTER MEDIA MUST BE PROTECTED. USE A FILTER FABRIC WITH A LAYER OF WASHED #2 STONE ON TOP. TOP OF RISER EL. = 521.00 15"Ø RCP TOP OF PIPE = 517.60 1 3 5 FT COMPACTED BERM SECTION (SEE BERM AND SOIL COMPACTION SPECIFICATIONS ON SHEET C9.100) PROPOSED GRADE 5 FT. WIDE MINIMUM KEY TRENCH (SEE BERM AND SOIL COMPACTION SPECIFICATIONS, DETAIL SHEET C9.100) KEY TRENCH TO BE PROVIDED PER THE DIRECTION OF THE SITE GEOTECHNICAL ENGINEER 2.0' (MIN) CONCRETE CRADLE (SEE DETAIL ON SHEET C9.103) SPILLWAY FILTER (SEE DETAIL SHEET C9.103) 15" CLASS III O-RING RCP INVERT EL. = 515.50 ENDWALL PER NCDOT STD. 700.25 (SEE DETAIL ON SHEET C9.102) VELOCITY DISSIPATOR NCDOT CLASS 'A' RIPRAP MINIMUM DIMENSIONS 5'L X 3.3'W X 12" THICK D50 = 3" TO BE LINED WITH GEOTEXTILE FABRIC OR EQUIVALENT (SEE DETAIL SHEET C9.103) NOTES: 1. REMOVED TOPSOIL SHALL BE STOCKPILED FOR USE IN PLANTING (SEEDING) THE DAM EMBANKMENT ONCE FINAL GRADES (AS SHOWN ON THE GRADING PLAN) HAVE BEEN ESTABLISHED WITH COMPACTED FILL. PRIOR TO TOPSOIL INSTALLATION, THE CONTRACTOR SHALL SCARIFY THE TOP 2- TO 3-INCHES OF THE BERMN SECTION TO PROMOTE BONDING OF THE TOPSOIL WITH THE COMPACTED FILL. THE TOPSOIL DEPTH SHALL RANGE FROM 3- TO 4-INCHES ON THE DAM EMBANKMENT. CONCRETE COLLAR (TO BE CONSTRUCTED IN THE FIELD BY THE CONTRACTOR, SEE DETAIL SHEET C9.102) 10' WIDE EMERGENCY SPILLWAY BERM IS NOT USED FOR MAINTENANCE ACCESS. REFER TO SHEET C9.100 FOR ACCESS CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-SWB.dwg, 4/14/2021 10:44:07 AM, Bernard, AndrewThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-SWB 3 1 N / A C9.102 STORMWATER CONTROL MEASURE "B" DETAILS MAINTENANCE ACCESS STEPS N.T.S. PERMANENT OUTLET STRUCTURE DETAILS N.T.S. N.T.S. RISER TRASH RACK DETAIL NOTES: 1.ALL REBAR TO BE #4 REBAR. 2.ALL REBAR AND ANGLES TO BE HOT-DIPPED GALVANIZED AND BE PROVIDED WITH AN EPOXY COATING. 3.THE HOT-DIPPED, GALVANIZED 2"x2"x1/4" ANGLES SHALL BE WELDED TO THE REBAR TRASH RACK. ONCE WELDED, THE ENTIRE ASSEMBLY SHALL BE PLACED ONTO THE RISER WITH ANGLES SITTING DIRECTLY ON TOP OF RISER. 4.CONTRACTOR SHALL ANCHOR THE TRASH RACK TO MANHOLE WALL WITH FOUR 4"x1/4" CONCRETE ANCHOR BOLTS THROUGH ANGLES. 5.CONTRACTOR SHALL OMIT OR ADJUST REBAR AS NECESSARY TO ALLOW FOR CONCRETE COLLAR. 6.ACCESS HATCH SHALL ALIGN WITH STEPS IN RISER. N.T.S. CONCRETE COLLAR DETAIL FRONT VIEW SIDE VIEW PROVIDE TRASH RACK ACROSS WEIR CONCRETE ANTI-FLOTATION BLOCK CONTRACTOR SHALL FORM INVERT OF RISER STRUCTURE TO DRAIN POSITIVELY TO INVERT OF OUTLET BARREL USING NON-SHRINK GROUT CONCRETE COLLAR (TO BE CONSTRUCTED IN THE FIELD BY THE CONTRACTOR, SEE DETAIL) 15"Ø O-RING RCP PRECASTER SHALL PROVIDE A BLOCK OUT FOR THE 15"Ø O-RING RCP INVERT EL. = 518.29 CONCRETE ANTI-FLOTATION BLOCK FLOW TOP OF RISER EL. = 521.00 15"Ø O-RING RCP FLOW 15"Ø O-RING RCP CONCRETE COLLAR (TO BE CONSTRUCTED IN THE FIELD BY THE CONTRACTOR, SEE DETAIL ) 20" 0.50' 7.02 PRECASTER SHALL PROVIDE A BLOCK OUT FOR THE 15"Ø O-RING RCP 1" THICK JOINT FILLER MATERIAL CONTRACTOR SHALL PROVIDE STEPS IN ACCORDANCE WITH NCDOT STD. 840.66. STEPS SHALL BE PLACED AT 16" O.C. AND SHALL LINE UP WITH ACCESS HATCH. CONTRACTOR SHALL PROVIDE STEPS IN ACCORDANCE WITH NCDOT STD. 840.66. STEPS SHALL BE PLACED AT 16" O.C. AND SHALL LINE UP WITH ACCESS HATCH. 4.85' 7.00'5.00' 1.00' 1.00' 7.00' 5'1.00'1.00' N.T.S. RISER JOINT CONNECTION DETAIL 3.0" 1 2"Ø GRADE 8 STAINLESS STEEL CONCRETE LAG SCREW 12" X 4" X 1 2" GALVANIZED STEEL STRAP (4 PER RISER JOINT) 6" NOTES: 1. CONCRETE ANTI-FLOTATION BLOCK TO BE PROVIDED WITH MINIMUM TEMPERATURE AND SHRINKAGE STEEL REINFORCEMENT. 2. TRASH RACKS NOT SHOWN FOR CLARITY. 3. THE NUMBER OF GUIDES FOR THE VALVE STEM SHALL BE DETERMINED IN THE FIELD BY THE CONTRACTOR. THE VALVE STEM MUST BE OPERABLE FROM THE TOP OF THE RISER VIA THE HANDWHEEL WITH AN INSIGNIFICANT AMOUNT OF PLAY IN THE VALVE STEM. 4. CONTRACTOR SHALL PROVIDE A JOINT IN THE OUTLET BARREL NO MORE THAN 5-FT FROM THE RISER. 6"Ø PERFORATED SCHEDULE 40 OR SDR 35 SMOOTH WALL PVC UNDERDRAIN PIPE @ 0.50% SLOPE (MIN.) (PER AASHTO M252) FROM SAND FILTER (TYP.) 6"Ø PERFORATED SCHEDULE 40 OR SDR 35 SMOOTH WALL PVC UNDERDRAIN PIPE (PER AASHTO M252)FROM SAND FILTER 6"Ø PERFORATED SCHEDULE 40 OR SDR 35 SMOOTH WALL PVC UNDERDRAIN PIPE (PER AASHTO M252)FROM SAND FILTER CONTRACTOR SHALL TIE SKIMMER PIPE INTO OPENING DURING CONSTRUCTON 4' OUTLET ENDWALL DETAILS N.T.S. CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-SWB.dwg, 4/14/2021 10:44:17 AM, Bernard, AndrewThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-SWB N / A C9.103 STORMWATER CONTROL MEASURE "B" DETAILS 1" THICK JOINT FILLER MATERIAL 15"Ø O-RING RCP 15"Ø O-RING RCP CONCRETE ANTI-FLOTATION BLOCK 1" THICK JOINT FILLER MATERIAL CONCRETE ANTI-FLOTATION BLOCK FLOW FLOW 1" THICK JOINT FILLER MATERIAL CONCRETE COLLAR (SEE DETAIL SHEET C9.02) NOTES: 1. CONTRACTOR SHALL PROVIDE A JOINT IN THE OUTLET BARREL NO MORE THAN 5-FT FROM THE RISER. TOP VIEW SIDE VIEW N.T.S. RISER BARREL/CRADLE CONNECTION DETAIL SPILLWAY FILTER DETAIL NO. 67 WASHED STONE ENCASED IN NON-WOVEN FILTER FABRIC (MIRAFI 180N OR EQUIVALENT) 1' MIN. 1' MIN. ENDWALL PER NCDOT STD. 838.80 15"Ø RCP FLOW PROPOSED GRADE 15"Ø RCP 4'-0" NO. 67 WASHED STONE ENCASED IN NON-WOVEN FILTER FABRIC (MIRAFI 180N OR EQUIVALENT) 17.5" O.D. 7'-7" ENDWALL PER NCDOT STD. 838.80 NOTE: 4" WEEPHOLES TO BE PROVIDED WITH VARMIT GUARD ON DOWNSTREAM SIDE AND GALVANIZED HARDWARE CLOTH ON UPSTREAM SIDE (1 4" MAXIMUM OPENINGS) 3'3' 59" NO. 67 WASHED STONE ENCASED IN NON-WOVEN FILTER FABRIC (MIRAFI 180N OR EQUIVALENT) ENDWALL PER NCDOT STD. 838.80 (2) 4" PERFORATED, CORRUGATED HDPE PIPE (DOUBLE-WALL SMOOTH BORE HDPE TYPE "S" OR ENGINEER APPROVED EQUIVALENT) (2) 4" PERFORATED, CORRUGATED HDPE PIPE (DOUBLE-WALL SMOOTH BORE HDPE TYPE "S" OR ENGINEER APPROVED EQUIVALENT) (2) 4" PERFORATED, CORRUGATED HDPE PIPE (DOUBLE-WALL SMOOTH BORE HDPE TYPE "S" OR ENGINEER APPROVED EQUIVALENT) 6" MIN. NOTES: 1.A FILTER BLANKET IS TO BE INSTALLED BETWEEN THE RIPRAP AND SOIL FOUNDATION. THE FILTER BLANKET WILL CONSIST OF A MINIMUM 4" THICK LAYER OF STONE (NCDOT #57) UNDERLAIN WITH MIRAFI FILTER WEAVE 700 OR ENGINEER APPROVED EQUIVALENT 2.HAVILAND DRAINAGE PRODUCTS 4" ALUMINUM ANIMAL GUARD ITEM NUMBER 40160420 (OR ENGINEER APPROVED EQUIVALENT) TO BE INSTALLED AT OUTLET OF 4" HDPE PIPES. 15"Ø RCP N.T.S. OUTLET BARREL VELOCITY DISSIPATOR PLAN SECTION A-A NOTES: 1.A FILTER BLANKET IS TO BE INSTALLED BETWEEN THE RIPRAP AND SOIL FOUNDATION. THE FILTER BLANKET WILL CONSIST OF A MINIMUM 4" THICK LAYER OF STONE (NCDOT #57) UNDERLAIN WITH MIRAFI FILTER WEAVE 700 OR APPROVED EQUIVALENT 24" CONCRETE CRADLE DETAIL N.T.S. 18" (TYP.) 3" COVER (MIN.) TO OUTSIDE OF #3 TIE BAR (TYP.) 18" C/C (TYP.) 3" FROM BOTTOM OF CRADLE TO CENTER OF #6 REBAR #6 REBAR (GRADE 60) #3 REBAR TIES (U-BARS) SPACED AT 10 FT. ON CENTER 1. IF OPTION 9.1 IS CHOSEN FROM NOTE 9 OF THE CONSTRUCTION SEQUENCE SHOWN ON SHEET C9.100, THEN BRING GRADE OF DAM EMBANKMENT TO SPRINGLINE OF PIPE ELEVATION. IF OPTION 9.2 IS CHOSEN FROM NOTE 9 OF THE CONSTRUCTION SEQUENCE, THEN CONSTRUCT FORMWORK FOR CONCRETE CRADLE ON EXISTING GRADE. 2. IF OPTION 9.1 IS CHOSEN FROM NOTE 9 OF THE CONSTRUCTION SEQUENCE SHOWN ON SHEET C9.100, THEN EXCAVATE TRENCH FOR CRADLE AND BARREL PER DIMENSIONS ON DRAWINGS. IF OPTION 9.2 IS CHOSEN FROM NOTE 9 OF THE CONSTRUCTION SEQUENCE, PROCEED TO STEP 3 BELOW. 3. PLACE REINFORCING STEEL AND JOINT FILLER MATERIAL PER DRAWINGS. ALL REINFORCING STEEL SHALL HAVE A MINIMUM OF 3" OF CONCRETE COVER (INCLUDING TIES). 4. PLACE BARREL PIPE ON CONCRETE BLOCKS TO GRADE. CONTRACTOR SHALL WRAP JOINTS WITH 2-FT WIDE STRIPS OF FABRIC AT THIS STEP. 5. POUR CONCRETE FOR CRADLE FOR EACH SECTION FROM ONE SIDE OF THE TRENCH. ALLOW CONCRETE TO FILL ENTIRE AREA UNDER PIPE AND PIPE HAUNCHES AS TO LEAVE NO VOIDS UNDER THE PIPE BEFORE POURING ON THE OPPOSITE SIDE OF THE TRENCH. POUR ENTIRE CRADLE AS ONE LIFT (VERTICALLY) PER DRAWINGS. 6. CONCRETE SHALL BE FINISHED "ROUGH" SO AS TO ACHIEVE A MORE ADEQUATE BOND BETWEEN THE CONCRETE IN THE CRADLE AND THE FIRST LIFT OF STRUCTURAL FILL. 7. ALLOW CRADLE TO CURE FOR A MINIMUM OF 7 DAYS BEFORE ANY VIBRATING COMPACTION EQUIPMENT IS USED IN THE VICINITY OF THE BARREL PIPE. NOTES: 1. ALL TIE BARS (U-BARS) ARE #3 (AS LABELED) REBAR (GRADE 60) SPACED AT 10 FT. CENTER TO CENTER ALONG THE LENGTH OF THE CRADLE. 2. MAINTAIN A MIN. COVER OF 3" OF CONCRETE (TO THE OUTSIDE OF THE REBAR) FOR ALL REINFORCEMENT. 3. TRENCH TO BE BACKFILLED IN 4" LIFTS WHEN COMPACTION IS BY HAND. BACKFILL IS IN 6" LIFTS WHEN CONDUCTED BY MACHINE. MINIMUM OF 2 FEET COVER MUST BE PRESENT ON 15"Ø RCP BEFORE DRIVING OVER WITH HEAVY EQUIPMENT. 4. REINFORCED CONCRETE CRADLE MAY BE REPLACED PER RECOMMENDATION FROM THE ON-SITE GEOTECHNICAL ENGINEER. ANY DEVIATION FROM THIS DETAIL SHALL BE SUBMITTED TO AND REVIEWED BY THE DESIGN ENGINEER PRIOR TO IMPLEMENTATION. 5. TESTING SHALL BE PERFORMED BY THE ON-SITE GEOTECHNICAL ENGINEER. A SLUMP TEST SHALL BE PERFORMED PRIOR TO PLACEMENT OF THE CRADLE. COMPRESSIVE STRENGTH TESTS SHALL BE PERFORMED TO ENSURE COMPLIANCE WITH SPECIFICATIONS LISTED TO THE RIGHT. BARREL PIPE CRADLE MATERIAL SPECIFICATIONS CONCRETE ·COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS (SEE NOTE #5) ·SHALL BE PLACED ON A 2- TO 2.5-INCH SLUMP (SEE NOTE #5) ·APPROVED MIX DESIGN ·4-6% AIR ENTRAINED ·MAXIMUM MIX TO POUR TIME OF 90 MINUTES ·FOUR CYLINDERS SHALL BE PREPARED FOR TESTING FOR EACH LIFT. ONE SHALL BE TESTED AT SEVEN DAYS, TWO AT 28 DAYS, AND THE FOURTH SHALL BE HELD FOR 54 DAYS. ·A MINIMUM OF 3" OF CONCRETE COVER ON ALL STEEL IS REQUIRED (INCLUDING TIES). ·CONCRETE TO BE VIBRATED VERTICALLY. WET CONCRETE SHALL NOT BE MOVED HORIZONTALLY WITH THE VIBRATOR. BARREL PIPE CONCRETE CRADLE CONSTRUCTION SEQUENCE STEEL ·ALL STEEL TO BE GRADE 60. ·ALL STEEL SHALL BE FREE OF RUST OR OTHER DEBRIS THAT MIGHT PREVENT BONDING TO THE CONCRETE. ·ALL STEEL SHALL BE BENT WITH A MINIMUM RADIUS OF 3DB (1.13" FOR #3) AS SHOWN ON THE DRAWINGS. ·THE #6 BARS IN THE CONCRETE CRADLE SHALL BE SPLICED WITH A MINIMUM OVERLAP OF 32". THE SPLICES SHALL BE SPACED SUCH THAT NO TWO SPLICES OCCUR WITHIN THE SAME LENGTH OF PIPE. 15"Ø O-RING RCP 54" MIN 8.00" (MIN.) 13.50" 1 1 (MIN.) 1 1 12" MIN. 5.94" C/C (TYP.) CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY MVD DRAWN BY AJB/JBW SCALE DATE 04.14.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-SWB.dwg, 4/14/2021 10:44:27 AM, Bernard, AndrewThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-SWB CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY DRAWN BY SCALE DATE 04.07.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-LS1.dwg, 4/12/2021 11:35:58 AM, Powell, BethThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-LS1 ANL BAP LS1.00 1"=40' CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R LANDSCAPE PLAN - OVERALL SITE LEGEND LANDSCAPE CALCULATIONS STREET TREES OVERALL TREES REQUIRED: 105 PROVIDED: 106 ENCORE LANE 300 LF TREES REQUIRED: 6 (1/50 LF) PROVIDED:6 STREET 'A' 1986 LF TREES REQUIRED: 40 (1/50 LF) PROVIDED:40 STREET 'B' 1798 LF TREES REQUIRED: 36 (1/50 LF) PROVIDED:36 STREET 'C'1134 LF TREES REQUIRED: 23 (1/50 LF) PROVIDED:24 PERIMETER BUFFER CUTHBERTSON ROAD FRONTAGE VARIABLE WIDTH BUFFER YARD SHADE TREES PROVIDED: 10 ORNAMENTAL TREES PROVIDED:57 EVERGREEN TREES PROVIDED:57 SHRUBS PROVIDED:193 GRAPHIC SCALE 0 30 60 120 1 inch = 60 ft. EXISTING CUTHBERTSON ROAD (PUBLIC R/W)ENCORE LANE(50' PUBLIC R/W)STREET 'A' (50' PUBLIC R/W) ST R E E T ' B ' (5 0 ' P U B L I C R / W ) S T R E E T ' C ' ( 5 0 ' P U B L I C R /W ) STORMWATER CONTROL MEASURE "A" STORMWATER CONTROL MEASURE "B" SB-A 540 SB-B 537 SB-C 541 SB-D 539 SB-H 516.0 0 CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY DRAWN BY SCALE DATE 04.07.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-LS1.dwg, 4/12/2021 11:36:07 AM, Powell, BethThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-LS1 ANL BAP LS1.01 1"=40' GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft. STREET 'A' (50' PUBLIC R/W) ST R E E T ' B ' (5 0 ' P U B L I C R / W ) S T R E E T ' C ' ( 5 0 ' PU B L I C R /W ) CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R TREE PROTECTION NOTES: ·PROPERTY OWNERS ARE RESPONSIBLE FOR ENSURING THAT ALL EXISTING TREES SHOWN ON APPROVED PLANS AS BEING RETAINED TO MEET THE REQUIREMENTS OF THIS ARTICLE ARE PROTECTED DURING THE CONSTRUCTION PROCESS FROM REMOVAL, DESTRUCTION, OR INJURY. BEFORE ANY EXCAVATION TAKES PLACE ON THE SUBJECT SITE, A BARRIER MUST BE ERECTED AROUND THE DRIP LINE OF ALL SUCH TREES SUFFICIENT TO PUT ON NOTICE ALL CONSTRUCTION PERSONNEL THAT ANY DISTURBANCE OF THE AREA WITHIN THE DRIPLINE OF SUCH TREES IS PROHIBITED, EXCEPT AS EXPRESSLY APPROVED BY THE ADMINISTRATOR. REQUIRED TREE BARRIERS MUST BE SHOWN ON CONSTRUCTION PLANS ·FOR PRESERVED VEGETATION, MAINTENANCE SHALL BEGIN AT THE TIME THAT THE ROOT PROTECTION ZONES ARE ESTABLISHED (PRIOR TO ROUGH GRADING) AND SHALL CONTINUE INDEFINITELY. FOR PLANTED MATERIALS, MAINTENANCE SHALL BEGIN AT THE TIME OF PLANTING AND SHALL CONTINUE INDEFINITELY EXISTING CUTHBERTSON ROAD (PUBLIC R/W)SEE SHEET LS1.02SEE SHEET LS1.02 LANDSCAPE PLAN - SOUTHENCORE LANE(50' PUBLIC R/W)SITE LEGEND SB-D 539 SB-E 517 SB-F 521.0 SB-G 518.0 0 SB-H 516.0 0 CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY DRAWN BY SCALE DATE 04.07.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-LS1.dwg, 4/12/2021 11:36:11 AM, Powell, BethThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-LS1 ANL BAP LS1.02 1"=40' GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R STORMWATER CONTROL MEASURE "A" (SEE C9.00 SHEETS)ST R E E T ' B ' (5 0 ' P U B L I C R / W ) STORMWATER CONTROL MEASURE "B" (SEE C9.00 SHEETS)SEE SHEET LS1.01SEE SHEET LS1.01 LANDSCAPE PLAN - NORTH TREE PROTECTION NOTES: ·PROPERTY OWNERS ARE RESPONSIBLE FOR ENSURING THAT ALL EXISTING TREES SHOWN ON APPROVED PLANS AS BEING RETAINED TO MEET THE REQUIREMENTS OF THIS ARTICLE ARE PROTECTED DURING THE CONSTRUCTION PROCESS FROM REMOVAL, DESTRUCTION, OR INJURY. BEFORE ANY EXCAVATION TAKES PLACE ON THE SUBJECT SITE, A BARRIER MUST BE ERECTED AROUND THE DRIP LINE OF ALL SUCH TREES SUFFICIENT TO PUT ON NOTICE ALL CONSTRUCTION PERSONNEL THAT ANY DISTURBANCE OF THE AREA WITHIN THE DRIPLINE OF SUCH TREES IS PROHIBITED, EXCEPT AS EXPRESSLY APPROVED BY THE ADMINISTRATOR. REQUIRED TREE BARRIERS MUST BE SHOWN ON CONSTRUCTION PLANS ·FOR PRESERVED VEGETATION, MAINTENANCE SHALL BEGIN AT THE TIME THAT THE ROOT PROTECTION ZONES ARE ESTABLISHED (PRIOR TO ROUGH GRADING) AND SHALL CONTINUE INDEFINITELY. FOR PLANTED MATERIALS, MAINTENANCE SHALL BEGIN AT THE TIME OF PLANTING AND SHALL CONTINUE INDEFINITELY SITE LEGEND CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY DRAWN BY SCALE DATE 04.07.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-LS1.dwg, 4/12/2021 11:36:14 AM, Powell, BethThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-LS1 ANL BAP LS1.03 1"=40' LANDSCAPE NOTES AND DETAILS CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R GENERAL LANDSCAPE NOTES: 1.ANY DEVIATION FROM THE PLANTS, SHRUBS OR TREES SELECTED WILL REQUIRE APPROVAL FROM UNION COUNTY PLANNING - URBAN FORESTRY. 2.FOR PRESERVED VEGETATION, MAINTENANCE SHALL BEGIN AT THE TIME THAT THE ROOT PROTECTION ZONES ARE ESTABLISHED (PRIOR TO ROUGH GRADING) AND SHALL CONTINUE INDEFINITELY. FOR PLANTED MATERIALS, MAINTENANCE SHALL BEGIN AT THE TIME OF PLANTING AND SHALL CONTINUE INDEFINITELY. 3.ALL MATERIALS AND METHODS OF CONSTRUCTION SHALL BE IN ACCORDANCE WITH UNION COUNTY AND THE STATE OF NORTH CAROLINA STANDARDS AND SPECIFICATIONS. 4.CONTRACTOR IS RESPONSIBLE FOR THE SITE INSPECTION BEFORE LANDSCAPE CONSTRUCTION AND INSTALLATION IN ORDER TO BECOME FAMILIAR WITH THE EXISTING CONDITIONS. 5.LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES BEFORE BEGINNING DEMOLITION OR INSTALLATION. 6.CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT OF ANY DISCREPANCIES BETWEEN THE NOTES, SPECIFICATIONS, DRAWINGS OR SITE CONDITIONS FOR RESOLUTION PRIOR TO INSTALLATION. 7.ANY DAMAGE TO UTILITIES SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE. 8.THIS PLAN IS FOR PLANTING PURPOSES ONLY. FOR INFORMATION REGARDING BUILDINGS, GRADING, WALLS, ETC., REFER TO ARCHITECTURE, SITE AND GRADING PLANS. 9.VERIFICATION OF TOTAL PLANT QUANTITIES AS SHOWN IN THE PLANT SCHEDULE SHALL BE THE RESPONSIBILITY OF THE LANDSCAPE CONTRACTOR. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE LANDSCAPE ARCHITECT. 10.CONTRACTOR TO ENSURE PROPER STABILIZATION AND SEEDING OF THE SITE IN ACCORDANCE WITH APPLICABLE REGULATIONS. 11.LANDSCAPE MATERIAL SHALL BE WELL FORMED, VIGOROUS, GROWING SPECIMENS WITH GROWTH TYPICAL OF VARIETIES SPECIFIED AND SHALL BE FREE FROM DAMAGE, INSECTS AND DISEASES. MATERIAL SHALL EQUAL OR SURPASS #1 QUALITY AS DEFINED IN THE CURRENT ISSUE OF “AMERICAN STANDARD FOR NURSERY STOCK” AS PUBLISHED BY THE AMERICAN NURSERY & LANDSCAPE ASSOCIATION. 12.ALL PLANT MATERIAL IS TO BE CAREFULLY HANDLED BY THE ROOT BALL, NOT THE TRUNK, BRANCHES AND/OR FOLIAGE OF THE PLANT. MISHANDLED PLANT MATERIAL MAY BE REJECTED BY THE LANDSCAPE ARCHITECT. 13.ALL PLANT MATERIAL IS TO BE WELL ROOTED, NOT ROOT BOUND, SUCH THAT THE ROOT BALL REMAINS INTACT THROUGHOUT THE PLANTING PROCESS. DEFICIENT PLANT MATERIAL MAY BE REJECTED BY THE LANDSCAPE ARCHITECT OR OWNER. 14.ALL PLANTS TO BE A MINIMUM OF WHAT IS SPECIFIED IN THE PLANT SCHEDULE. ANY CHANGES OR SUBSTITUTIONS SHALL BE APPROVED BY THE LANDSCAPE ARCHITECT AND GOVERNING JURISDICTION PRIOR TO ANY HOLE BEING DUG. 15.CONTRACTOR TO COORDINATE WITH OWNER'S REPRESENTATIVE AND LANDSCAPE ARCHITECT TO ESTABLISH THE EXTENTS OF MULCH/SEED/SOD IF NOT SPECIFICALLY SHOWN ON PLANS. 16.CONTRACTOR SHALL PROVIDE POSITIVE DRAINAGE IN ALL PLANTING AREAS. 17.PROPOSED TREES TO BE PLANTED A MINIMUM 10 FEET FROM ANY LIGHT POLE AS MEASURED FROM TRUNK OF THE TREE TO THE POLE. 18.PROPOSED TREES TO BE PLANTED A MINIMUM 5 FEET FROM ANY FIRE HYDRANT AS MEASURED FROM TRUNK OF THE TREE TO THE HYDRANT. 19.CONTRACTOR SHALL COMPLETE SOIL TEST IN ALL PLANTING AREAS TO DETERMINE SOIL AMENDMENT REQUIREMENTS UNLESS WAIVED BY OWNER'S REPRESENTATIVE. CONTRACTOR SHALL ADJUST PH AND FERTILITY BASED UPON THE SOIL TEST RESULTS. 20.TOPSOIL SHALL BE FREE OF MATERIAL LARGER THAN 1.0 INCH IN DIAMETER OR LENGTH AND SHALL NOT CONTAIN SLAG, CINDERS, STONES, LUMPS OF SOIL, STICKS, ROOTS, TRASH, CHEMICAL RESIDUES, OR OTHER EXTRANEOUS MATERIAL. 21.APPLY SOIL AMENDMENTS AND FERTILIZERS AS REQUIRED BY THE SOIL TEST RESULTS TO ACHIEVE A HEALTHY GROWING MEDIA AND MIX THOROUGHLY INTO TOP 4 INCHES OF SOIL. SPREAD PLANTING SOIL MIX TO A DEPTH OF 6 INCHES BUT NOT LESS THAN REQUIRED TO MEET FINISH GRADES AFTER NATURAL SETTLEMENT. DO NOT SPREAD IF PLANTING SOIL OR SUBGRADE IS FROZEN, MUDDY, OR EXCESSIVELY WET. 22.IF IMPORTED TOPSOIL IS REQUIRED, THE SUBGRADE SHALL BE SCARIFIED OR TILLED TO A DEPTH OF AT LEAST 6 INCHES PRIOR TO INSTALLATION OF IMPORTED TOPSOIL. FOLLOWING INSTALLATION OF IMPORTED TOPSOIL, THE TOPSOIL SHALL BE TILLED TO INTEGRATE THE SOIL PROFILES. 23.ALL TREE PLANTINGS SHALL BE MULCHED TO A DEPTH OF 3 INCHES, AND WITH A MINIMUM 4 FOOT RADIUS FROM BASE OF TREE OR TO DRIPLINE. MULCH SHALL BE FREE OF TRASH AND MAINTAINED WEED FREE. MULCH SHALL NOT COVER THE ROOT FLARE. CONFIRM MULCH SPECIFICATIONS WITH OWNER'S REPRESENTATIVE OR LANDSCAPE ARCHITECT. 24.PLANT MATERIALS ARE TO BE GUARANTEED FOR A PERIOD OF 12 MONTHS. PLANT MATERIALS WHICH REMAIN UNHEALTHY WILL BE REPLACED BY THE LANDSCAPE CONTRACTOR BEFORE THE EXPIRATION OF THE GUARANTEE PERIOD OR IMMEDIATELY IF SO DIRECTED BY THE OWNER'S REPRESENTATIVE OR LANDSCAPE ARCHITECT. 25.DO NOT PRUNE TREES AND SHRUBS BEFORE DELIVERY. PROTECT BARK, BRANCHES, AND ROOT SYSTEMS FROM SUN SCALD, DRYING, SWEATING, WHIPPING, AND OTHER HANDLING AND TYING DAMAGE. DO NOT BEND OR BIND-TIE TREES OR SHRUBS IN SUCH A MANNER AS TO DESTROY THEIR NATURAL SHAPE. PROVIDE PROTECTIVE COVERING OF EXTERIOR PLANTS DURING DELIVERY. DO NOT DROP EXTERIOR PLANTS DURING DELIVERY AND HANDLING. 26.DELIVER EXTERIOR PLANTS AFTER PREPARATIONS FOR PLANTING HAVE BEEN COMPLETED AND INSTALL IMMEDIATELY. IMMEDIATELY AFTER UNLOADING, STAND THE TREES UP TO REDUCE THE RISK OF SUN SCALD. PROPERLY STAGED TREES ARE STANDING, UNTIED AND SPACED. UNLESS IMMEDIATELY INSTALLED, SET EXTERIOR PLANTS AND TREES IN SHADE, PROTECT FROM WEATHER AND MECHANICAL DAMAGE, AND KEEP ROOTS MOIST. 27.SEE LANDSCAPE DETAILS FOR TREE STAKING REQUIREMENTS. 28.EXCAVATE EDGES OF ALL PLANTING BEDS TO 2 INCH DEPTH TO FORM A NEAT AND CRISP DEFINITION. 29.CONTRACTOR SHALL REMOVE DEBRIS AND FINE GRADE ALL PLANTING AREAS PRIOR TO INSTALLATION. 30.REMOVE GUY WIRES AND STAKES AT END OF WARRANTY PERIOD OR ESTABLISHMENT. 31.FINISH GRADING: GRADE PLANTING AREAS TO A SMOOTH, UNIFORM SURFACE PLANE WITH LOOSE, UNIFORMLY FINE TEXTURE. GRADE TO WITHIN PLUS OR MINUS 1/2 INCH OF FINISH ELEVATION. ROLL AND RAKE, REMOVE RIDGES, AND FILL DEPRESSIONS TO MEET FINISH GRADES. LIMIT FINISHED GRADING TO AREAS THAT CAN BE PLANTED IN THE IMMEDIATE FUTURE. CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY DRAWN BY SCALE DATE 04.07.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-LS1.dwg, 4/12/2021 11:36:22 AM, Powell, BethThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-LS1 ANL BAP LS1.04 1"=40' GRAPHIC SCALE 0 10 20 40 1 inch = 20 ft. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R TREE PROTECTION NOTES: ·PROPERTY OWNERS ARE RESPONSIBLE FOR ENSURING THAT ALL EXISTING TREES SHOWN ON APPROVED PLANS AS BEING RETAINED TO MEET THE REQUIREMENTS OF THIS ARTICLE ARE PROTECTED DURING THE CONSTRUCTION PROCESS FROM REMOVAL, DESTRUCTION, OR INJURY. BEFORE ANY EXCAVATION TAKES PLACE ON THE SUBJECT SITE, A BARRIER MUST BE ERECTED AROUND THE DRIP LINE OF ALL SUCH TREES SUFFICIENT TO PUT ON NOTICE ALL CONSTRUCTION PERSONNEL THAT ANY DISTURBANCE OF THE AREA WITHIN THE DRIPLINE OF SUCH TREES IS PROHIBITED, EXCEPT AS EXPRESSLY APPROVED BY THE ADMINISTRATOR. REQUIRED TREE BARRIERS MUST BE SHOWN ON CONSTRUCTION PLANS ·FOR PRESERVED VEGETATION, MAINTENANCE SHALL BEGIN AT THE TIME THAT THE ROOT PROTECTION ZONES ARE ESTABLISHED (PRIOR TO ROUGH GRADING) AND SHALL CONTINUE INDEFINITELY. FOR PLANTED MATERIALS, MAINTENANCE SHALL BEGIN AT THE TIME OF PLANTING AND SHALL CONTINUE INDEFINITELYSTREET 'A'(50' PUBLIC R/W)EXISTING CUTHBERTSON ROAD (PUBLIC R/W) TREE INVENTORYENCORE LANE(50' PUBLIC R/W)SITE LEGEND ENLARGEMENT 1 EXISTING TREES SUMMARY TREE LEGEND ENLARGEMENT 1 CONT. ENLARGEMENT 2 - EAST ENLARGEMENT 1 - WEST ENLARGEMENT 2 - EASTENLARGEMENT 1 - WESTENLARGEMENT 2 TREE#SPECIES DBHPLAN LOCATION TREE#SPECIES DBHPLAN LOCATION TREE LEGEND CLIENT REVISIONS PROJECT NO.DWH-19010 FILENAME CHECKED BY DRAWN BY SCALE DATE 04.07.2021 N0.DATE Y:\Projects\DWH\DWH-19010\04-Production\Engineering - Townhomes\Construction Drawings\Current Drawings\DWH19010-LS1.dwg, 4/12/2021 11:36:27 AM, Powell, BethThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 CUTHBERTSON TOWNHOMESCONSTRUCTION DRAWINGS2219 CUTHBERTSON ROADWAXHAW, NORTH CAROLINA, 28173SHEET PLAN INFORMATION FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION DAVID WEEKLEY HOMES - CHARLOTTE DIVISION 11430 NORTH COMMUNITY HOUSE ROAD SUITE 275, CHARLOTTE, NC 28277 PHONE: 704. 972. 4205 DWH19010-LS1 ANL BAP LS1.05 1"=40' GRAPHIC SCALE 0 10 20 40 1 inch = 20 ft. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R TREE PROTECTION NOTES: ·PROPERTY OWNERS ARE RESPONSIBLE FOR ENSURING THAT ALL EXISTING TREES SHOWN ON APPROVED PLANS AS BEING RETAINED TO MEET THE REQUIREMENTS OF THIS ARTICLE ARE PROTECTED DURING THE CONSTRUCTION PROCESS FROM REMOVAL, DESTRUCTION, OR INJURY. BEFORE ANY EXCAVATION TAKES PLACE ON THE SUBJECT SITE, A BARRIER MUST BE ERECTED AROUND THE DRIP LINE OF ALL SUCH TREES SUFFICIENT TO PUT ON NOTICE ALL CONSTRUCTION PERSONNEL THAT ANY DISTURBANCE OF THE AREA WITHIN THE DRIPLINE OF SUCH TREES IS PROHIBITED, EXCEPT AS EXPRESSLY APPROVED BY THE ADMINISTRATOR. REQUIRED TREE BARRIERS MUST BE SHOWN ON CONSTRUCTION PLANS ·FOR PRESERVED VEGETATION, MAINTENANCE SHALL BEGIN AT THE TIME THAT THE ROOT PROTECTION ZONES ARE ESTABLISHED (PRIOR TO ROUGH GRADING) AND SHALL CONTINUE INDEFINITELY. FOR PLANTED MATERIALS, MAINTENANCE SHALL BEGIN AT THE TIME OF PLANTING AND SHALL CONTINUE INDEFINITELY EXISTING CUTHBERTSON ROAD (PUBLIC R/W) TREE MITIGATIONENCORE LANE(50' PUBLIC R/W)SITE LEGEND ENLARGEMENT 2 ENLARGEMENT 1 TREES REMOVED SUMMARY ENLARGEMENT 2 CEDAR TOTAL DBH REMOVED 112 125% OF REMOVED DBH 140 PROVIDED MITIGATION DBH 142 MITIGATION TREES * JUNIPERUS VIRGINIANA / EASTERN RED CEDAR JUNIPERUS VIRGINIANA 'IDYLLWILD' / IDYLLWILD RED CEDAR 6' HT. MIN. QTY 57 TREE MITIGATION SUMMARY TREE#SPECIES DBHPLAN LOCATION CHERRY TOTAL DBH REMOVED 24 125% OF REMOVED DBH 30 PROVIDED MITIGATION DBH 36 MITIGATION TREES * AMELANCHIER ARBOREA / DOWNY SERVICEBERRY MALUS SARGENTII 'FIREBIRD' / SARGENT CRAB APPLE 2" CAL. MIN. 6' HT. MIN. QTY 18 SWEET GUM TOTAL DBH REMOVED 12 125% OF REMOVED DBH 15 PROVIDED MITIGATION DBH 15 MITIGATION TREES LIQUIDAMBAR STYRACIFLUA / SWEET GUM 2.5" CAL. MIN. 8' HT. MIN. QTY 6 OAK TOTAL DBH REMOVED 124 125% OF REMOVED DBH 155 PROVIDED MITIGATION DBH 155 MITIGATION TREES * QUERCUS LYRATA / OVERCUP OAK QUERCUS PHELLOS / WILLOW OAK QUERCUS SHUMARDII / SHUMARD OAK CARPINUS BETULUS 'FASTIGIATA' / PYRAMIDAL HORNBEAM CLEDITSIA TRIACANTHOS INERMIS 'SKYCOLE' / SKYLINE THORNLESS HONEY LOCUST SALIX BABYLONICA / WEEPING WILLOW 2.5" CAL. MIN. 8' HT. MIN. QTY 61 ENLARGEMENT 2 - EAST ENLARGEMENT 1 - WEST ENLARGEMENT 2 - EASTENLARGEMENT 1 - WESTSTREET 'A'(50' PUBLIC R/W)* PORTIONS OF THE TREE MITIGATION AREA ALONG CUTHBERTSON ROAD ARE WITHIN A 30' OVERHEAD POWERLINE EASEMENT. PLANTINGS WITHIN THE EASEMENT ARE REQUIRED TO REMAIN 15' MAX. HEIGHT. NATIVE TREE SPECIES ARE USED TO THE EXTENT POSSIBLE. SELECTED CULTIVARS OR VARIETIES ARE SIMILAR TO INVENTORIED SPECIES WHERE POWER EASEMENT LIMITS PLANT HEIGHT.