Loading...
HomeMy WebLinkAboutNC0034967_Fact Sheet_20210426Fact Sheet NPDES Permit No. NC0034967 Permit Writer/Email Contact: Derek Denard, derek.denard@ncdenr.gov Date: 26Apr2021 Division/Branch: NC Division of Water Resources/Water Quality Permitting Section Compliance & Expediated Permitting Branch Fact Sheet Template: Version 28Mar2019 Permitting Action: ❑X Renewal ❑ Renewal with Expansion ❑ New Discharge ❑ Modification (Fact Sheet should be tailored to mod request) See Permit Application Attachment A Complete applicable sections below. If not applicable, enter NA. 1. Basic Facility Information Facility Information Applicant/Facility Name: Carolina Glove Company, Inc./ Carolina Glove Company Applicant Address: PO Box 999, Conover, NC 28613 Facility Address: 140 Glove Mill Road, Taylorsville, NC 28681 Permitted Flow: 0.015 MGD Facility Type/Waste: privately owned treatment systems treating 100% domestic wastewaters < 1. MGD Facility Class: Grade II Biological WPCS Treatment Units: Comminutor, aeration basin with 2 blower units, clarification charger with airlift recycle and skimmer, chlorine contact chamber [no chlorine usage at present], and sludge return. Pretreatment Program (Y/N) No County: Alexander Region Mooresville Briefly describe the proposed permitting action and facility background: Carolina Glove Company has applied for the renewal of NPDES permit NC0034967. The facility is an existing wastewater treatment facility for 100% domestic wastewaters generated from manufacturing plant with 65 employees. The collection system is separate (sanitary sewer only). [See Permit Application Attachment A] Page 1 of 7 2. Receiving Waterbodv Information: Receiving Waterbody Information Outfalls/Receiving Stream(s): Outfall 001 / Lower Little River Stream Index: 11-69-(0.5) Stream Classification: C Drainage Area (mi2): Maybe available in NPDES permit file with original WLA. Summer 7Q10 (cfs) 12.8 Winter 7Q10 (cfs): 21.7 30Q2 (cfs): 30.6 Average Flow (cfs): 71.4 IWC (% effluent): 0.18 [See Attachment B] 303(d) listed/parameter: 11-69-(0.5)b is listed for Fish Community (Nar, AL, FW) [See Attachment C] Subject to TMDL/parameter: Not applicable Basin/Sub-basin/HUC: Catawba / 03-08-32 / HUC: 030501011003 USGS Topo Quad: Taylorsville, NC 3. Effluent Data Summary Effluent data for Outfall 001 is summarized below for the period of Jan2015 through Jan2020. Table. Effluent Data Summary Outfall 001 (Compete table below or insert Excel Pivot Table.) Data Parameter V. Max Min 'Average Count PQL MA DM UoM 00010 - Temperature, 30 8 19.7 240 deg c Water Deg. 50050 - Flow, in 0.00332 0.0000758 0.000764 242 0.015 mgd conduit or thru C0310 - BOD, 5-Day 39.7 2 8.0 228 2 30 45 mg/I (20 Deg. C) - C0530 - Solids, Total 34 2.5 11.11 228 2.5 30 45 mg/I Suspended - PQL - Practical Quantitation Limit, MA - Monthly Average, DM - Daily Max, UoM - Units of Measurement Limits Page 2 of 7 4. Instream Data Summary Instream monitoring may be required in certain situations, for example: 1) to verify model predictions when model results for instream DO are within 1 mg/1 of instream standard at full permitted flow; 2) to verify model predictions for outfall diffuser; 3) to provide data for future TMDL; 4) based on other instream concerns. Instream monitoring may be conducted by the Permittee, and there are also Monitoring Coalitions established in several basins that conduct instream sampling for the Permittee (in which case instream monitoring is waived in the permit as long as coalition membership is maintained). If applicable, summarize any instream data and what instream monitoring will be proposed for this permit action: Not applicable. Is this facility a member of a Monitoring Coalition with waived instream monitoring (Y/N): Not applicable. Name of Monitoring Coalition: Not applicable. 5. Compliance Summary Summarize the compliance record with permit effluent limits (past 5 years): No violations noted for Mar2015 to Mar2020 data pull. [See Attachment D] Summarize the compliance record with aquatic toxicity test limits and any second species test results (past 5 years): Aquatic toxicity monitoring is not required. Summarize the results from the most recent compliance inspection: A March 28, 2019 compliance evaluation inspection indicated compliance. [See Attachment E] 6. Water Quality -Based Effluent Limitations (WQBELs) Dilution and Mixing Zones In accordance with 15A NCAC 2B.0206, the following streamflows are used for dilution considerations for development of WQBELs: 1Q10 streamflow (acute Aquatic Life); 7Q10 streamflow (chronic Aquatic Life; non -carcinogen HH); 30Q2 streamflow (aesthetics); annual average flow (carcinogen, HH). If applicable, describe any other dilution factors considered (e.g., based on CORMIX model results): Not applicable. If applicable, describe any mixing zones established in accordance with 15A NCAC 2B. 0204(b): Not applicable. Oxygen -Consuming Waste Limitations Limitations for oxygen -consuming waste (e.g., BOD) are generally based on water quality modeling to ensure protection of the instream dissolved oxygen (DO) water quality standard. Secondary TBEL limits (e.g., BOD= 30 mg/1 for Municipals) may be appropriate if deemed more stringent based on dilution and model results. If permit limits are more stringent than TBELs, describe how limits were developed: Not applicable. Page 3 of 7 Ammonia and Total Residual Chlorine Limitations Limitations for ammonia are based on protection of aquatic life utilizing an ammonia chronic criterion of 1.0 mg/1 (summer) and 1.8 mg/1 (winter). Acute ammonia limits are derived from chronic criteria, utilizing a multiplication factor of 3 for Municipals and a multiplication factor of 5 for Non -Municipals. Limitations for Total Residual Chlorine (TRC) are based on the NC water quality standard for protection of aquatic life (17 ug/1) and capped at 28 ug/1 (acute impacts). Due to analytical issues, all TRC values reported below 50 ug/1 are considered compliant with their permit limit. Describe any proposed changes to ammonia and/or TRC limits for this permit renewal: Not applicable. Reasonable Potential Analysis (RPA) for Toxicants Not applicable Toxicity Testing Limitations Permit limits and monitoring requirements for Whole Effluent Toxicity (WET) have been established in accordance with Division guidance (per WET Memo, 8/2/1999). Per WET guidance, all NPDES permits issued to Major facilities or any facility discharging "complex" wastewater (contains anything other than domestic waste) will contain appropriate WET limits and monitoring requirements, with several exceptions. The State has received prior EPA approval to use an Alternative WET Test Procedure in NPDES permits, using single concentration screening tests, with multiple dilution follow-up upon a test failure. Describe proposed toxicity test requirement: Aquatic toxicity monitoring is not required. Mercury Statewide TMDL Evaluation There is a statewide TMDL for mercury approved by EPA in 2012. The TMDL target was to comply with EPA's mercury fish tissue criteria (0.3 mg/kg) for human health protection. The TMDL established a wasteload allocation for point sources of 37 kg/year (81 lb/year), and is applicable to municipals and industrial facilities with known mercury discharges. Given the small contribution of mercury from point sources (-2% of total load), the TMDL emphasizes mercury minimization plans (M1VIPs) for point source control. Municipal facilities > 2 MGD and discharging quantifiable levels of mercury (>1 ng/1) will receive an MMP requirement. Industrials are evaluated on a case -by -case basis, depending if mercury is a pollutant of concern. Effluent limits may also be added if annual average effluent concentrations exceed the WQBEL value (based on the NC WQS of 12 ng/1) and/or if any individual value exceeds a TBEL value of 47 ng/1 Describe proposed permit actions based on mercury evaluation: Not required. Other TMDL/Nutrient Management Strategy Considerations If applicable, describe any other TMDLs/Nutrient Management Strategies and their implementation within this permit: Not applicable. Page 4 of 7 Other WQBEL Considerations If applicable, describe any other parameters of concern evaluated for WQBELs: Not applicable. If applicable, describe any special actions (HQW or ORW) this receiving stream and classification shall comply with in order to protect the designated waterbody: Not applicable. If applicable, describe any compliance schedules proposed for this permit renewal in accordance with 15A NCAC 2H.0107(c)(2)(B), 40CFR 122.47, and EPA May 2007 Memo: Not applicable. If applicable, describe any water quality standards variances proposed in accordance with NCGS 143- 215.3(e) and 15A NCAC 2B. 0226 for this permit renewal: Not applicable. 7. Technology -Based Effluent Limitations (TBELs) Are concentration limits in the permit at least as stringent as secondary treatment requirements (30 mg/l BOD5/TSS for Monthly Average, and 45 mg/l for BOD5/TSS for Weekly Average)? Yes, expect daily maximum is 45 mg/1. Used NPDES Application Form D for privately owned treatment systems treating 100% domestic wastewaters < 1. MGD. 8. Antidegradation Review (New/Expanding Discharge): The objective of an antidegradation review is to ensure that a new or increased pollutant loading will not degrade water quality. Permitting actions for new or expanding discharges require an antidegradation review in accordance with 15A NCAC 2B.0201. Each applicant for a new/expanding NPDES permit must document an effort to consider non -discharge alternatives per 15A NCAC 2H.0105( c)(2). In all cases, existing instream water uses and the level of water quality necessary to protect the existing use is maintained and protected. If applicable, describe the results of the antidegradation review, including the Engineering Alternatives Analysis (EAA) and any water quality modeling results: Not applicable. 9. Antibacksliding Review: Sections 402(o)(2) and 303(d)(4) of the CWA and federal regulations at 40 CFR 122.44(1) prohibit backsliding of effluent limitations in NPDES permits. These provisions require effluent limitations in a reissued permit to be as stringent as those in the previous permit, with some exceptions where limitations may be relaxed (e.g., based on new information, increases in production may warrant less stringent TBEL limits, or WQBELs may be less stringent based on updated RPA or dilution). Are any effluent limitations less stringent than previous permit (YES/NO): NO. If YES, confirm that antibacksliding provisions are not violated: Not applicable. Page 5 of 7 10. Monitoring Requirements Monitoring frequencies for NPDES permitting are established in accordance with the following regulations and guidance: 1) State Regulation for Surface Water Monitoring, 15A NCAC 2B.0500; 2) NPDES Guidance, Monitoring Frequency for Toxic Substances (7/15/2010 Memo); 3) NPDES Guidance, Reduced Monitoring Frequencies for Facilities with Superior Compliance (10/22/2012 Memo); 4) Best Professional Judgement (BPJ). Per US EPA (Interim Guidance, 1996), monitoring requirements are not considered effluent limitations under Section 402(o) of the Clean Water Act, and therefore anti - backsliding prohibitions would not be triggered by reductions in monitoring frequencies. For instream monitoring, refer to Section 4. 11. Electronic Reporting Requirements The US EPA NPDES Electronic Reporting Rule was finalized on December 21, 2015. Effective December 21, 2016, NPDES regulated facilities are required to submit Discharge Monitoring Reports (DMRs) electronically. Effective December 21, 2020, NPDES regulated facilities will be required to submit additional NPDES reports electronically. This permit contains the requirements for electronic reporting, consistent with Federal requirements. 12. Summary of Proposed Permitting Actions: A. Table. Current Permit Conditions and Proposed Changes — Outfall 001 Parameter Current Permit Proposed Change Basis for Condition/Change Flow (MGD) MA 0.015 MGD No change 15A NCAC 2B .0505 BOD 5-day (20°C) MA 30 mg/1 DM 45 mg/1 No change TBEL. Secondary treatment standards/40 CFR 133 / 15A NCAC 2B .0406 Total Suspended Solids (TSS) MA 30 mg/1 DM 45 mg/1 No change TBEL. Secondary treatment standards/40 CFR 133 / 15A NCAC 2B .0406 Temperature (°C) Monitor &Report No change State WQ standard, 15A NCAC 2B .0200 Electronic Reporting Electronic Reporting Special Condition Update In accordance with EPA Electronic Reporting Rule 2015. MGD — Million gallons per day, MA - Monthly Average, WA — Weekly Average, DM — Daily Max The draft permit includes the following significant changes from the existing permit: 1. The permit map and supplement to cover page was updated. 2. The facility classification Grade II Biological Water Pollution Control System (WPCS) was added to the effluent page. 3. The electronic reporting permit special condition was updated. Page 6 of 7 13. Public Notice Schedule: Permit to Public Notice: 08/07/2020 [See Attachment F] Per 15A NCAC 2H .0109 & .0111, The Division will receive comments for a period of 30 days following the publication date of the public notice. Any request for a public hearing shall be submitted to the Director within the 30 days comment period indicating the interest of the party filing such request and the reasons why a hearing is warranted. 14. Fact Sheet Addendum (if applicable): Were there any changes made since the Draft Permit was public noticed (Yes/No): No. If Yes, list changes and their basis below: NA. 15. Fact Sheet Attachments (list in order of reference): A. NC0034967 Renewal (Application)_20191220_5p B. NC0034967 WLA NH3 TRC Fecallp C. 2018-NC-303-d--List-Final 45 D. NC0034967 MR Violations Jan2015_Jan2020_2p E. NC0034967_Inspection _20190328_7p F. Affidavit of Publication The Taylorsville Times_ 20200715_lpStaff Report_Ori Tuiva_20200617 G. Staff Report _Ori Tuiva 20200617_lp H. Peer Review Emily Phillilps_20200617_2p I. Electronic Transmittal Approval_ Daniel Nichols_20200707_2p J. NC0034967 Review Checklist_lp K. QAQC202104233p L. Electronic Transmittal Receipt_Daniel Nichols_2020426_2p Page 7 of 7 ROY COOPER Gmernor MICHAEL S. REGAN 5ccrcrc,r, LINDA CULPEPPER Carolina Glove Company, Inc. Attn: Daniel A. Nichols, Engineering Manager PO Box 999 Conover, NC 28613 Subject: Permit Renewal Application No. NC0034967 Carolina Glove Company Alexander County NORTH CAROLINA Environmental Quality December 20, 2019 Dear Applicant: The Water Quality Permitting Section acknowledges the December 20, 2019 receipt of your permit renewal application and supporting documentation. Your application will be assigned to a permit writer within the Section's NPDES WW permitting branch. Per G.S. 150B-3 your current permit does not expire until permit decision on the application is made. Continuation of the current permit is contingent on timely and sufficient application for renewal of the current permit. The permit writer will contact you if additional information is required to complete your permit renewal. Please respond in a timely manner to requests for additional information necessary to allow a complete review of the application and renewal of the permit. Information regarding the status of your renewal application can be found online using the Department of Environmental Quality's Environmental Application Tracker at: https://deq. nc.gov/permits-regulations/permit-guidance/environmental-application-tracker If you have any additional questions about the permit, please contact the primary reviewer of the application using the links available within the Application Tracker. Sincerely Wren Thedford Administrative Assistant Water Quality Permitting Section ec: WQPS Laserfiche File w/application North Caro ra Department of Env rormerle Qcs tti I D vsor of Water Resotroes Nsoresv,eReg ora Off.oel910East :erterAven&e,Sute3OiIMooresv e.North Caro na 29115 734.663-199 9 NPDES APPLICATION - FORM D For privately owned treatment systems treating 100% domestic wastewaters <1.0 MGD Mail the complete application to: N. C. DENR / Division of Water Quality / NPDES Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 NPDES Permit NC000034967 If you are completing this form in computer use the TAB key or the up - down arrows to move from one field to the next. To check the boxes, click your mouse on top of the box. Otherwise, please print or type. 1. Contact Information: Owner Name Carolina Glove Company, Inc. Facility Name Carolina Glove Company Mailing Address PO Box 999 City Conover DEC 2 0 2019 State / Zip Code NC Telephone Number 828-464-1132 NCDEQ/DWR/NPDES Fax Number (828)4641710 e-mail Address dnichols@carolinaglovecompany.com 2. Location of facility producing discharge: Check here if same address as above ❑ Street Address or State Road 140 Glove Mill Road City State / Zip Code County Taylorsville NC Alaxander 3. Operator Information: Name of the firm, public organization or other entity that operates the facility. (Note that this is not referring to the Operator in Responsible Charge or ORC) Name Mailing Address City State / Zip Code Telephone Number Fax Number Carolina Glove Company PO Box 999 Conover NC (828)464-1132 (828)464-1710 1 of 4 �I r G O " Form-D 05/08 NPDES APPLICATION - FORM D For privately owned treatment systems treating 100% domestic wastewaters <1.0 MGD 4. Description of wastewater: Facility Generating Wastewater(check all that apply): Industrial x❑ Number of Employees 65 Commercial ❑ Number of Employees Residential ❑ Number of Homes School ❑ Number of Students/Staff Other ❑ Explain: Describe the source(s) of wastewater (example: subdivision, mobile home park, shopping centers, restaurants, etc.): Manufacturing Plant Population served: 65 5. Type of collection system x❑ Separate (sanitary sewer only) ❑ Combined (storm sewer and sanitary sewer) 6. Outfall Information: Number of separate discharge points 1 Outfall Identification number(s) .001 Is the outfall equipped with a diffuser? ❑ Yes x❑ No 7. Name of receiving stream(s) (Provide a map showing the exact location of each outfall): Lower Little River 8. Frequency of Discharge: x❑ Continuous ❑ Intermittent If intermittent: Days per week discharge occurs: Duration: 9. Describe the treatment system List all installed components, including capacities, provide design removal for BOD, TSS, nitrogen and phosphorus. If the space provided is not sufficient, attach the description of the treatment system in a separate sheet of paper. The plant is a .015 MGD Extended air package system consisting of: 1 Comminutor, Aerotion Basin with 2 blower units, a Clarifacation Charger with Airlift recycle & skimmer, flow exits the plant through a small chlorine contact chamber (no CL used), outfall is through a small v-notch weir, exiting out a 6" PCV pipe into the Lower Little River. BOD-TSS removal should be 90-95% respectively. Nitrogen @ 80-85%. No phosphate 2 of 4 Form-D 05/08 NPDES APPLICATION - FORM D For privately owned treatment systems treating 100% domestic wastewaters <1.0 MGD 3 of 4 Form-D 05/08 • NPDES APPLICATION - FORM D For privately owned treatment systems treating 100% domestic wastewaters <1.0 MGD 10. Flow Information: Treatment Plant Design flow .015 MGD Annual Average daily flow .0006 MGD (for the previous 3 years) Maximum daily flow .0001 MGD (for the previous 3 years) 11. Is this facility located on Indian country? ❑ Yes x❑ No 12. Effluent Data Provide data for the parameters listed. Fecal Coliform, Temperature and pH shall be grab samples, for all other parameters 24-hour composite sampling shall be used. If more than one analysis is reported, report daily maximum and monthly average. If only one analysis is reported, report as daily maximum. Parameter Daily Maximum Monthly Average Units of Measurement Biochemical Oxygen Demand (BOD5) 2.4 Mg/1 Fecal Coliform - n/a Total Suspended Solids 9 Rng/1 Temperature (Summer) 26 C Temperature (Winter) 3 C pH - n/a 13. List all permits, construction approvals and/or applications: Type Permit Number Type Hazardous Waste (RCRA) NESHAPS (CAA) UIC (SDWA) Ocean Dumping (MPRSA) NPDES NC0034967 Dredge or fill (Section 404 or CWA) PSD (CAA) Other Non -attainment program (CAA) 14. APPLICANT CERTIFICATION Permit Number I certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, complete, and accurate. DareteL ' 11icli00 EM5 me,e Printed name of Person Signing Title 00/144A) Ct at)) la- lb- ,o)c) Signature of Applicant Date North Carolina General Statute 143-215.6 (b)(2) states: Any person who knowingly makes any false statement representation, or certification in any application, record, report, plan, or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $25,000, or by imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $25,000 or imprisonment not more than 5 years, or both, for a similar offense.) 4 of 4 Form-D 05/08 IWC Calculations Facility: Carolina Glove Company, Inc. NC0034967 Prepared By: Derek Denard Enter Design Flow (MGD): Enter s7Q10 (cfs): Enter w7Q10 (cfs): 0.015 12.8 21.7 Total Residual Chlorine (TRC) Daily Maximum Limit (ug/I) s7Q10 (CFS) DESIGN FLOW (MGD) DESIGN FLOW (CFS) STREAM STD (UG/L) Upstream Bkgd (ug/I) IWC (%) Allowable Conc. (ug/I) Fecal Coliform Monthly Average Limit: (If DF >331; Monitor) (If DF<331; Limit) Dilution Factor (DF) 12.8 0.015 0.02325 17.0 0 0.18 9376 Ammonia (Summer) Monthly Average Limit (mg NH3-N/I) s7Q10 (CFS) DESIGN FLOW (MGD) DESIGN FLOW (CFS) STREAM STD (MG/L) Upstream Bkgd (mg/I) IWC (%) Allowable Conc. (mg/I) Ammonia (Winter) Monthly Average Limit (mg NH3-N/I) w7Q10 (CFS) Vet Required DESIGN FLOW (MGD) DESIGN FLOW (CFS) STREAM STD (MG/L) 551.54 Upstream Bkgd (mg/I) IWC (%) Allowable Conc. (mg/I) Total Residual Chlorine 1. Cap Daily Max limit at 28 ug/I to protect for acute toxicity Ammonia (as NH3-N) 1. If Allowable Conc > 35 mg/I, Monitor Only 2. Monthly Avg limit x 3 = Weekly Avg limit (Municipals); capped at 35 mg/I 3. Monthly Avg limit x 5 = Daily Max limit (Non-Munis); capped at 35 mg/I 4. BAT for Minor Domestics: 2 mg/I (summer) and 4 mg/I (winter) 5. BAT for Major Municipals: 1 mg/I (year-round) 12.8 0.015 0.02325 1.0 0.22 0.18 430.4 21.7 0.015 0.02325 1.8 0.22 0.11 1476.5 Fecal Coliform 1. Monthly Avg limit x 2 = 400/100 ml = Weekly Avg limit (Municipals) = Daily Max limit (Non -Muni) NPDES Server/Current Versions/WLA; TB 1/16/2009 2018 NC Category 5 Assessments "303(d) List" Final Catawba River Basin 11-69-(0.5)b Upper Catawba Subbasin 03050101 D_Es} WMUMlMrMMu..,\ -• Lower Little River From Lambert Fork to a point 0.5 mile upstream of mouth of Stirewalt Creek Classification C Length or Area 6 Units FW Miles Previous AU Number 11-69-(0.5) Assessment Criteria Status Reason for Rating Parameter of Interest Category Exceeding Criteria Fair Fish Community (Nar, AL, FW) 5 11-44-(3) McGalliard Creek From a point 0.6 mile upstream of mouth to Rhodhiss Lake, Catawba River Classification WS-IV;CA Length or Area 4 Units FW Miles Previous AU Number Assessment Criteria Status Reason for Rating Parameter of Interest Category Exceeding Criteria Poor Fish Community (Nar, AL, FW) 5 11-135-2 McGill Creek From source to Crowders Creek Classification C Length or Area 3 Units FW Miles Previous AU Number Assessment Criteria Status Reason for Rating Parameter of Interest Category Exceeding Criteria Fair Benthos (Nar, AL, FW) 5 11-76-5-(3) McLin Creek From a point 0.2 mile upstream of Catawba County SR 1722 to Lyle Creek Classification WS-IV;CA Length or Area 1 Units FW Miles Previous AU Number Assessment Criteria Status Reason for Rating ■ Paramter of Interest Category Exceeding Criteria 11-69-4 Fair Benthos (Nar, AL, FW) 5 Muddy Fork From source to SR 1409 Classification C Length or Area 7 Units FW Miles Previous AU Number Assessment Criteria Status Reason for Rating Exceeding Criteria Parameter of Interest Category Fair Benthos (Nar, AL, FW) 5 6/3/2019 2018 NC Category 5 Assessments "303(d) List" Approved by EPA May 22,2019 Page 45 of 262 MONITORING REPORT(MR) VIOLATIONS for: Report Date: 03/11/20 Page 1 of 2 Permit: NC0034967 MRs Betweel 3 - 2015 and 3 - 2020 Facility Name: % Param Name% Major Minor: % Region: County: % Violation Category:% Subbasin:% Program Category: Violation Action: % PERMIT: NC0034967 FACILITY: Carolina Glove Company - Carolina Glove Company COUNTY: Alexander REGION: Mooresville Monitoring Violation MONITORING OUTFACE REPORT LOCATION PARAMETER VIOLATION UNIT OF DATE FREQUENCY MEASURE LIMIT CALCULATED VALUE ok Over VIOLATION TYPE VIOLATION ACTION 07-2016 001 12-2016 001 07-2017 001 12-2017 001 07-2018 001 12-2018 001 12-2019 001 07-2016 001 12-2016 001 07-2017 001 12-2017 001 07-2018 001 12-2018 001 12-2019 001 07-2016 001 Effluent Effluent Effluent Effluent Effluent Effluent Effluent Effluent Effluent Effluent Effluent Effluent Effluent Effluent Effluent BOD, 5-Day (20 Deg. C) - Concentration BOD, 5-Day (20 Deg. C) - Concentration BOD, 5-Day (20 Deg. C) - Concentration BOD, 5-Day (20 Deg. C) - Concentration BOD, 5-Day (20 Deg. C) - Concentration BOD, 5-Day (20 Deg. C) - Concentration BOD, 5-Day (20 Deg. C) - 12/28/19 Concentration Flow, in conduit or thru treatment plant Flow, in conduit or thru treatment plant Flow, in conduit or thru treatment plant Flow, in conduit or thru treatment plant Flow, in conduit or thru treatment plant Flow, in conduit or thru treatment plant Flow, in conduit or thru treatment plant Solids, Total Suspended - Concentration 07/09/16 12/31/16 07/08/17 12/30/17 07/07/18 12/29/18 Weekly Weekly Weekly Weekly Weekly Weekly Weekly 07/09/16 Weekly 12/31/16 Weekly 07/08/17 Weekly 12/30/17 Weekly 07/07/18 Weekly 12/29/18 Weekly 12/28/19 Weekly 07/09/16 Weekly mg/I mg/I mg/I mg/I mg/I mg/I mg/I mgd mgd mgd mgd mgd mgd mgd mg/I Frequency Violation Frequency Violation Frequency Violation Frequency Violation Frequency Violation Frequency Violation Frequency Violation Frequency Violation Frequency Violation Frequency Violation Frequency Violation Frequency Violation Frequency Violation Frequency Violation Frequency Violation No Action, Facility Reporting Error No Action, Facility Reporting Error No Action, BIMS Calculation Error No Action, BIMS Calculation Error No Action, BIMS Calculation Error No Action, BIMS Calculation Error No Action, BIMS Calculation Error No Action, Facility Reporting Error No Action, Facility Reporting Error No Action, BIMS Calculation Error No Action, BIMS Calculation Error No Action, BIMS Calculation Error No Action, BIMS Calculation Error No Action, BIMS Calculation Error No Action, Facility Reporting Error MONITORING REPORT(MR) VIOLATIONS for: Report Date: 03/11/20 Page 2 of 2 Permit: NC0034967 MRs Betweel 3 - 2015 and 3 - 2020 Facility Name: % Param Name% Major Minor: % Region: County: % Violation Category:% Subbasin:% Program Category: Violation Action: % PERMIT: NC0034967 FACILITY: Carolina Glove Company - Carolina Glove Company COUNTY: Alexander REGION: Mooresville Monitoring Violation MONITORING OUTFACE REPORT LOCATION PARAMETER VIOLATION UNIT OF DATE FREQUENCY MEASURE LIMIT CALCULATED VALUE ok Over VIOLATION TYPE VIOLATION ACTION 12-2016 001 07-2017 001 12-2017 001 07-2018 001 12-2018 001 12-2019 001 07-2016 001 12-2016 001 07-2017 001 12-2017 001 07-2018 001 12-2018 001 12-2019 001 Effluent Effluent Effluent Effluent Effluent Effluent Effluent Effluent Effluent Effluent Effluent Effluent Effluent Solids, Total Suspended - Concentration Solids, Total Suspended - Concentration Solids, Total Suspended - Concentration Solids, Total Suspended - Concentration Solids, Total Suspended - Concentration Solids, Total Suspended - Concentration Temperature, Water Deg. Centigrade Temperature, Water Deg. Centigrade Temperature, Water Deg. Centigrade Temperature, Water Deg. Centigrade Temperature, Water Deg. Centigrade Temperature, Water Deg. Centigrade Temperature, Water Deg. Centigrade 12/31/16 Weekly 07/08/17 Weekly 12/30/17 Weekly 07/07/18 Weekly 12/29/18 Weekly 12/28/19 Weekly 07/09/16 Weekly 12/31/16 Weekly 07/08/17 Weekly 12/30/17 Weekly 07/07/18 Weekly 12/29/18 Weekly 12/28/19 Weekly mg/I mg/I mg/I mg/I mg/I mg/I deg c deg c deg c deg c deg c deg c deg c Frequency Violation Frequency Violation Frequency Violation Frequency Violation Frequency Violation Frequency Violation Frequency Violation Frequency Violation Frequency Violation Frequency Violation Frequency Violation Frequency Violation Frequency Violation No Action, Facility Reporting Error No Action, BIMS Calculation Error No Action, BIMS Calculation Error No Action, BIMS Calculation Error No Action, BIMS Calculation Error No Action, BIMS Calculation Error No Action, Facility Reporting Error No Action, Facility Reporting Error No Action, BIMS Calculation Error No Action, BIMS Calculation Error No Action, BIMS Calculation Error No Action, BIMS Calculation Error No Action, BIMS Calculation Error ROY COOPER Governor MICHAEL S. REGAN Secretary LINDA CULPEPPER Director Mr. Daniel Nicholas Carolina Glove Company P.O. Box 999 Conover, NC 28613 Dear Mr. Nicholas: r NORTH CAROLINA Eetwiratimrrfted Quality March 28, 2019 Subject: Compliance Evaluation Inspection Carolina Glove Company WWTP NPDES Permit No. NC0034967 Alexander County Enclosed is a copy of the Compliance Evaluation Inspection for the inspection conducted at the subject facility on March 27, 2019, by Ori Tuvia. Brian Eades cooperation during the site visit was much appreciated. Please advise the staff involved with this NPDES Permit by forwarding a copy of the enclosed report. The report should be self-explanatory; however, should you have any questions concerning this report, please do not hesitate to contact Ori Tuvia at (704) 235-2190, or at ori.tuvia(a,ncdenr. gov. Cc: NPDES, MRO Files (Laserfiche) Sincerely, DocuSigned by: A44444v H P44,e4 F161FB69A2D84A3... fo r W. Corey Basinger Regional Supervisor Mooresville Regional Office Division of Water Resources State of North Carolina I Environmental Quality I Water Resources I Water Quality Regional Operations Mooresville Regional Office 1610 East Center Avenue, Suite 301 I Mooresville, North Carolina 28115 704 663 1699 United States Environmental Protection Agency EPA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction 1 IN I 21I I I I Code NPDES yr/mo/day Inspection 2 IL I 'I NC0034967 111 12 I 19/03/27 117 Type 18 I c I I I I I I Inspector Fac Type 19 I S I 201 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 166 l Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved 6711.0 I 70 LJ Id I 71 IN I 72 I N I 73 174 751 I I I I I 1 180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Carolina Glove Company 140 Glove Mill Rd Taylorsville NC 28681 Entry Time/Date 12:15PM 19/03/27 Permit Effective Date 15/07/01 Exit Time/Date 12:45PM 19/03/27 Permit Expiration Date 20/03/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Steve Brian Eades/ORC/828-632-5280/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Misty Smith, //828-396-4444/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance Records/Reports Self -Monitoring Program Facility Site Review Effluent/Receiving Waters Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) Ori A Tuvia of Inspector(s) Agency/Office/Phone and Fax Numbers Date 3/28/2019 f---DocuSigned by: MRO WQ//704-663-1699/ �� BB057A2DE017498... Signature of Management Q A Reviewer Agency/Office/Phone and Fax f Andrew Pitner MRO WQ//704-663-1699 Ext.21 uummberrsusigned by: Date A44144VHP4 \—F161F869A2D84A3... 3.28.19 EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# 1 NPDES yr/mo/day Inspection Type 31 NC0034967 111 121 19/03/27 117 18 LI 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Page# 2 Permit: NC0034967 Inspection Date: 03/27/2019 Owner - Facility: Carolina Glove Company Inspection Type: Compliance Evaluation Permit (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: The current permit expires on March 31, 2020. Record Keeping Are records kept and maintained as required by the permit? Is all required information readily available, complete and current? Are all records maintained for 3 years (lab. reg. required 5 years)? Are analytical results consistent with data reported on DMRs? Is the chain -of -custody complete? Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? Has the facility submitted its annual compliance report to users and DWQ? (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Facility has copy of previous year's Annual Report on file for review? Yes No NA NE ❑ ❑ • ❑ ▪ ❑ ❑ ❑ ❑ • ❑ ❑ MOD MOOD Yes No NA NE MOOD ❑ ❑ ❑ ■ ❑ ❑ ❑ • • ❑ ❑ ❑ ❑ ❑ ❑ • MODE• • ❑ ❑ � ❑ ❑ ❑•❑ ▪ ❑ ❑ ❑ ▪ ❑ ❑ ❑ ■ ❑ ❑ ❑ ▪ ❑ ❑ ❑ Comment: The permittee's records were organized and well maintained and records requested during the inspection were readily retrievable. DMRs, COCs, ORC logs and calibration logs were reviewed for the period September 2018 through January 2019. Effluent Sampling Yes No NA NE Page# 3 Permit: NC0034967 Inspection Date: 03/27/2019 Owner - Facility: Carolina Glove Company Inspection Type: Compliance Evaluation Effluent Sampling Is composite sampling flow proportional? Is sample collected below all treatment units? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Comment: Grab sampling is required by the subject permit. Laboratory Are field parameters performed by certified personnel or laboratory? Are all other parameters(excluding field parameters) performed by a certified lab? # Is the facility using a contract lab? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? Yes No NA NE ❑ ❑ • ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ▪ ❑ ❑ ❑ Yes No NA NE ▪ ❑ ❑ ❑ ▪ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ Comment: On -site analyses (temperature) are performed under field laboratory certification #5062 (Town of Taylorsville). A review of the field instrumentation used on site was performed during the Town of Taylorsville WWTP inspection (performed prior to this site inspection). Water Tech Labs, Inc. (Certification #50) performs all remaining permit -required effluent analyses Operations & Maintenance Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Yes No NA NE ▪ ❑ ❑ ❑ ❑ ❑ • ❑ Comment: The facility appeared to be well operated and maintained at the time of the inspection. Aeration Basins Mode of operation Type of aeration system Is the basin free of dead spots? Are surface aerators and mixers operational? Are the diffusers operational? Yes No NA NE Ext. Air Diffused ▪ ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ Page# 4 Permit: NC0034967 Inspection Date: 03/27/2019 Owner - Facility: Carolina Glove Company Inspection Type: Compliance Evaluation Aeration Basins Is the foam the proper color for the treatment process? Does the foam cover less than 25% of the basin's surface? Is the DO level acceptable? Is the DO level acceptable?(1.0 to 3.0 mg/I) Comment: Secondary Clarifier Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately'/ of the sidewall depth) Comment: Flow Measurement - Effluent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Yes No NA NE • ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ OM ❑ ❑ ❑ • Yes No NA NE • ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ ▪ ❑ ❑ ❑ ■ ❑ ❑ ❑ ▪ ❑ ❑ ❑ Yes No NA NE ❑ • ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ Comment: The facility was granted a conditional variance on 9/8/04 to use the facility's water usage records for the flow measurement calculations and these are being used by the ORC for DMR reporting. Effluent Pipe Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Comment: Yes No NA NE ▪ ❑ ❑ ❑ ▪ ❑ ❑ ❑ ❑ ❑ • ❑ Page# 5 Permit: NC0034967 Inspection Date: 03/27/2019 Owner - Facility: Carolina Glove Company Inspection Type: Compliance Evaluation Effluent Pipe Yes No NA NE Page# 6 Publisher's Certificate North Carolina Alexander County: I, Walter Lee Sharpe, Publisher of The Taylorsville Times, a weekly newspaper published at Taylorsville, Alexander County, North Carolina, being duly sworn says, that the attached notice was duly published in said paper for weeks, beginning with the issue dated the ¶S day of Signed Gla&i, VAIL Publisher -7 ioG. Date Fee $�'�;5 Subscribed and sworn before me this l day of �1,4C,'viS�l i 202D My Commission Expires t 120 /z-4 Q V 47 Public Notice North Carolina Environmental Management Commission/NPDES Unit 1617 Mail Service Center Raleigh, NC 27699-1617 Notice of Intent to Issue a NPDES Wastewater Permit NC0034967 Carolina Glove Company The North Carolina Environmental Management Commission proposes to issue a NPDES wastewater dis- charge permit to the persons) listed below. Written comments regard- ing the proposed permit will be accepted until 30 days after the publish date of this notice. The Director of the NC Division of Water Resources (DWR) may hold a public hear- ing should there be a sig- nificant degree of public interest. Please mail com- ments and/or information requests to DWR at the above address. Interested persons may visit the DWR at 512 N. Salisbury Street, Raleigh, NC to review information on file. Additional information on NPDES permits and this notice may be found on our website: http://deq.nc.gov/ about/divisions/water- resources/water-resourc- es-permits/was tewater- branch/npdes-wastewa- ter/public-notices,or by calling (919) 707-3601. Carolina Glove Company requested renewal of NPDES permit NC0034967 for its WWTP/Alexander County. Facility discharg- es treated wastewater to the Lower Little River/ Catawba River Basin. Currently no parameters are water quality limited. jul15-20c RE: Drafting Initiated for NC0034967 Carolina Glove Company Tuvia, Ori A <ori.tuvia@ncdenr.gov> Wed 6/17/2020 11:43 AM To: Denard, Derek <derek.denard@ncdenr.gov> Cc: Pitner, Andrew <andrew.pitner@ncdenr.gov> Derek, I do not have any special concerns regarding the permit renewal, however this is one of the few facilities that is not require to disinfect their wastewater prior to discharge. One item to note is that in the past year there was a major storm that caused the river to flood the entire surrounding area including the WWTP. The WWTP was completely underwater and was fully repaired. Before going back to operation. From: Denard, Derek Sent: Thursday, June 11, 2020 5:30 PM To: Tuvia, Ori A <ori.tuvia@ncdenr.gov> Cc: Pitner, Andrew <andrew.pitner@ncdenr.gov> Subject: Drafting Initiated for NC0034967 Carolina Glove Company Ori, I have started on the renewal for NC0034967 Carolina Glove Company. I will have a draft ready soon. Let me know if you have any information that comes to mind for the renewal. Thanks, Derek Denard Environmental Specialist N.C. Division of Water Resources N.C. Department of Environmental Quality 919 707 3618 office 919 707 9000 main DWR derek.denard@ncdenr.gov 1617 Mail Service Center Raleigh, NC 27699-1617 Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. RE: Peer Review for NC0034967 Carolina Glove Company Phillips, Emily <Emily.Phillips@ncdenr.gov> Thu 6/18/2020 1:51 PM To: Denard, Derek <derek.denard@ncdenr.gov> Everything looks really good. And I updated the PN system for you. I'm hanging in there. From: Denard, Derek Sent: Wednesday, June 17, 2020 4:29 PM To: Phillips, Emily <Emily.Phillips@ncdenr.gov> Subject: Peer Review for NC0034967 Carolina Glove Company Emily, Attached below is a shared peer review folder from my OneDrive. There is a Peer Review sub -folder that has everything you need with the folder for NC0034967 Carolina Glove Company. You can see all my other files for the project too if you want to see them. Can you put the public notice statement into Access for me? I still don't have VPN and this will be my first permit to public notice since the pandemic started. I feel like I am starting a new job and don't know the process. Hope you are doing well. Thanks, Derek E4 Peer Review Derek Denard Environmental Specialist N.C. Division of Water Resources N.C. Department of Environmental Quality 919 707 3618 office 919 707 9000 main DWR derek.denard@ncdenr.gov 1617 Mail Service Center Raleigh, NC 27699-1617 Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. 11/26/2020 Mail - Denard, Derek - Outlook [External] Re: Draft NPDES Permit NC0034967- Carolina Glove Company - Grade II Biological WPCS Daniel Nichols<dnichols@carolinaglovecompany.com> J 10:59 AM To: Denard, Derek <derek.denard@ncdenr.gov> CAUTIO External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment Derek: To the best of my ability, this looks fine Thank you Dan On Monday, July 6, 2020, 4:19:00 PM EDT, Denard, Derek <derek.denard@ncdenr.gov> wrote: Dear Mr. Nichols, Please find the attached draft NPDES Permit NC0034967 for Carolina Glove Company. A hard copy is being mail to you shortly. In order to provide more convenience, control, and security to our permittees and assist them in processing their transactions, The Division of Water Resources is currently transitioning towards electronic correspondence. This will hopefully provide more efficient service to our permittees and other partners and will allow us to more effectively process and track documents. We are writing to ask you for your approval of the transmittal of documents related to your permitting and related activities with the Division in an electronic format. Documents will be emailed to the appropriate contact person(s) in your organization in a PDF format. Please respond to me through email with verification that transmittal of your documents in an electronic manner is acceptable to you. If you have any questions, please feel free to contact me. Sincerely, Derek Denard Environmental Specialist N.C. Division of Water Resources N.C. Department of Environmental Quality 919 707 3618 office 919 707 9000 main DWR derek.denard@ncdenr.gov 1617 Mail Service Center Raleigh, NC 27699-1617 Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. https://outlook.office365.com/mail/AAMkADdhYTVmZDBILTE5ZDctNG15MC04Zj1iLWU4Mj VhZTBhMmJkMgAuAAAAAADg3GZR8iZnTYW56121 cjmNA... 1/2 11/26/2020 Mail - Denard, Derek - Outlook https://outlook.office365.com/mail/AAMkADdhYTVmZDBILTE5ZDctNG15MC04Zj1iLWU4Mj VhZTBhMmJkMgAuAAAAAADg3GZR8iZnTYW56121 cjmNA... 2/2 NPDES PERMIT NEW / RENEWAL DRAFT / FINAL CHECK LIST Permittee Carolina Glove Company, Inc. Facility Carolina Glove Company Permit No. NC0034967 Stream Class C Regional Office MRO Permit Writer Derek Denard Add. Info. Requested [BIMS Events]: NA Add. Info. Received [BIMS Events]: NA Permit Drafting Initiated [BIMS Events] (review application for completeness) 03/18/2020 RO staff report requested [BIMS Events], sent email to: Tuvia, Ori A <ori.tuvia@ncdenr.gov> 06/11/2020 RO staff report received [BIMS Events] : Tuvia, Ori A <ori.tuvia@ncdenr.gov> Pitner, Andrew <andrew.pitner@ncdenr.gov> 06/17/2020 EAA Review (new or expanding) NA Complete Draft Permit, Cover Letter, Create Edit Map 06/16/2020 Update/ Create Permit Outfall (Lat/Lon, HUC code, etc.) [BIMS] 12/04/2020 Data/RPA Review 06/17/2020 Draft Fact Sheet & Fact Sheet Binder 06/17/2020 Proof Read for Peer Review 06/17/2020 Submit Cover, Permit, Map, Factsheet Binder (including Application, Add. Info.) for Peer Review by Emily Phillips 06/17/2020 Peer Review Completed 06/18/2020 Region comments on draft requested to (see draft to whom list): Tuvia, Ori A <ori.tuvia@ncdenr.gov>; Pitner, Andrew <andrew.pitner@ncdenr.gov> 06/17/2020 07/06/2020 Region comments on draft received from: Tuvia, Ori A <ori.tuvia@ncdenr.gov>; Pitner, Andrew <andrew.pitner@cdenr.gov> Request for Approval of Electronic Transmittals Daniel Nichols <dnichols@carolinaglovecompany.com> 07/06/2020 Response Daniel Nichols <dnichols@carolinaglovecompany.com> 07/07/2020 Prepare Public Notice Statement 06/17/2020 Proof Read Draft for Public Notice 07/06/2020 Updated Public Notice System 06/18/2020 Submitted for Public Notice to Wren Thedford 07/06/2020 Draft to additional reviewers ATB [BIMS Events]: hannah.headrick@ncdenr.gov; cindy.a.moore@ncdenr.gov NA Draft from additional reviewers ATB [BIMS Events]: NA Draft to additional reviewers WOCG [BIMS Events]:Maureen.Kinney@ncdenr.gov 07/06/2020 Draft from additional reviewers WOCG [BIMS Events]:Maureen.Kinney@ncdenr.gov None If stream class WS, Draft to additional reviewers PWS (see draft to whom list) [BIMS Events]: NA If stream class WS, Draft form additional reviewers PWS [BIMS Events]: NA Other agency comments requested(see draft to whom list, for S —DMF / Shellfish)[BIMS Events]: NA Other agency comments received [BIMS Events]: NA Public notice published [BIMS Events] 08/07/2020 BIMS Scheduled Issuance Date [BIMS Events - automatic] 09/21/2020 4/23/2021 Mail - Denard, Derek - Outlook Re: Issuance of NPDES Permit NC0034967 - Carolina Glove Company Denard, Derek <derek.denard@ncdenr.gov> Fri 4/23/2021 6:01 PM To: Weaver, Charles <charles.weaver@ncdenr.gov> Charles, A/QC looks good. Derek Derek Denard Environmental Specialist N.C. Division of Water Resources N.C. Department of Environmental Quality 919 707 3618 office 919 707 9000 main DWR derek.denard@nclenr.gov 1617 Mail Service Center Raleigh, NC 27699-1617 Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Weaver, Charles <charles.weaver@ncdenr.gov> Sent: Tuesday, January 19, 2021 12:40 PM To: Denard, Derek <derek.denard@ncdenr.gov> Subject: Re: Issuance of NPDES Permit NC0034967 - Carolina Glove Company NC0034967 has been issued in BIMS. You can QA/QC at your discretion. CHW Messages sent to or from this address are subject to the North Carolina Public Records Law. From: Denard, Derek <derek.denard@ncdenr.gov> Sent: Monday, January 18, 2021 1:34 AM To: Daniel Nichols Cc: Basinger, Corey; Tuvia, Ori A; Pitner, Andrew; Kinney, Maureen; Weaver, Charles Subject: Issuance of NPDES Permit NC0034967 - Carolina Glove Company https://outlook.office365.com/mail/AAMkADdhYTVmZDBILTESZDctNG15MC04Zj1iLWU4MjVhZTBhMmJkMgAuAAAAAADg3GZR8iZnTYW56121 cjmNA... 1/3 4/23/2021 Mail - Denard, Derek - Outlook Dear Mr. Nichols, Please find the issuance of NPDES Permit NC0034967 for Carolina Glove Company. A hard copy is being mail to you shortly. In order to provide more convenience, control, and security to our permittees and assist them in processing their transactions, The Division of Water Resources is currently transitioning towards electronic correspondence. This will hopefully provide more efficient service to our permittees and other partners and will allow us to more effectively process and track documents. We are writing to ask you for your approval of the transmittal of documents related to your permitting and related activities with the Division in an electronic format. Documents will be emailed to the appropriate contact person(s) in your organization in a PDF format. Please respond to this email confirming that you received the attached document(s), were able to open and view the document(s) and have saved/printed a copy for your records. Sincerely, Derek Denard Environmental Specialist N.C. Division of Water Resources N.C. Department of Environmental Quality 919 707 3618 office 919 707 9000 main DWR derek.denard@ncdenr.gov<mailto:derek.denard@ncdenr.gov> 1617 Mail Service Center Raleigh, NC 27699-1617 https://outlook.office365.com/mail/AAMkADdhYTVmZDBILTESZDctNG15MC04Zj1iLWU4MjVhZTBhMmJkMgAuAAAAAADg3GZR8iZnTYW56121 cjmNA... 2/3 4/23/2021 Mail - Denard, Derek - Outlook Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. https://outlook.office365.com/mail/AAMkADdhYTVmZDBILTESZDctNG15MC04Zj1iLWU4MjVhZTBhMmJkMgAuAAAAAADg3GZR8iZnTYW56121 cjmNA... 3/3 4/26/2021 Mail - Denard, Derek - Outlook [External] Re: Issuance of NPDES Permit NC0034967 - Carolina Glove Company Daniel Nichols <dnichols@carolinaglovecompany.com> Mon 4/26/2021 7:56 AM To: Denard, Derek <derek.denard@ncdenr.gov> CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Derek: The permit has been received ad fordwarded to Allen at the Taylorsville location. Thank you Dan Nichols On Friday, April 23, 2021, 5:44:57 PM EDT, Denard, Derek <derek.denard@ncdenr.gov> wrote: Mr. Nichols, Please verify that you are in receipt of the permit we issued in January so I may close out the files. Thanks, Derek Denard Environmental Specialist N.C. Division of Water Resources N.C. Department of Environmental Quality 919 707 3618 office 919 707 9000 main DWR derek.denard@ncdenr.gov 1617 Mail Service Center Raleigh, NC 27699-1617 Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Denard, Derek <derek.denard@ncdenr.gov> Sent: Monday, January 18, 2021 1:34 AM To: Daniel Nichols <dnichols@carolinaglovecompany.com> Cc: Basinger, Corey <corey.basinger@ncdenr.gov>; Tuvia, Ori A <ori.tuvia@ncdenr.gov>; Pitner, Andrew <andrew.pitner@ncdenr.gov>; Kinney, Maureen <Maureen.Kinney@ncdenr.gov>; Weaver, Charles <charles.weaver@ncdenr.gov> Subject: Issuance of NPDES Permit NC0034967 - Carolina Glove Company Dear Mr. Nichols, https://outlook.office365.com/mail/inbox/id/AAQkADdhYTVmZDBILTESZDctNGI5MC04ZjliLWU4MjVhZTBhMmJkMgAQAA8Ka7UF7YNPrs8Mgwc%2F... 1/2 4/26/2021 Mail - Denard, Derek - Outlook Please find the issuance of NPDES Permit NC0034967 for Carolina Glove Company. A hard copy is being mail to you shortly. In order to provide more convenience, control, and security to our permittees and assist them in processing their transactions, The Division of Water Resources is currently transitioning towards electronic correspondence. This will hopefully provide more efficient service to our permittees and other partners and will allow us to more effectively process and track documents. We are writing to ask you for your approval of the transmittal of documents related to your permitting and related activities with the Division in an electronic format. Documents will be emailed to the appropriate contact person(s) in your organization in a PDF format. Please respond to this email confirming that you received the attached document(s), were able to open and view the document(s) and have saved/printed a copy for your records. Sincerely, Derek Denard Environmental Specialist N.C. Division of Water Resources N.C. Department of Environmental Quality 919 707 3618 office 919 707 9000 main DWR derek.denard@ncdenr.gov 1617 Mail Service Center Raleigh, NC 27699-1617 Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. https://outlook.office365.com/mail/inbox/id/AAQkADdhYTVmZDBILTESZDctNGI5MC04ZjliLWU4MjVhZTBhMmJkMgAQAA8Ka7UF7YNPrs8Mgwc%2F... 2/2