Loading...
HomeMy WebLinkAboutNC0020052_Permit (Issuance)_20050303 NPDES DOCUMENT SCANNIMG COVER SLEET NPDES Permit: NCO020052 McAdenville WWTP Document Type: ., ermit Issuanc Wasteload Allocation Authorization to Construct (AtC) Permit Modification Speculative Limits Compliance Instream Assessment (67B) Environmental Assessment (EA) Permit History Document Date: March 3, 2005 � LI:0 document ies prixzted axM ruse paper-Bore e.3My coateat o1,the re-%rez a INICIe NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Michael F. Easley, Governor William G. Ross,Jr., Secretary Alan W. Klimek, P.E., Director March 3,2005 Mr. Mike Church Town of McAdenville 100 Main Street McAdenville, North Carolina 28101 Subject: Issuance of NPDES Permit NC0020052 McAdenville WWTP Gaston County Dear,Mx, Churcli: Division personnel have reviewed and approved your application for renewal of the subject permit. Accordingly, we are forwarding the attached NPDES discharge permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215-1 and the Memorandum of Agreement between North Carolina and the U.S. Environmental Protection Agency dated May 9, 1994 (or as subsequently amended). This final permit includes no major changes from the draft permit sent to you on October 27, 2004. Please make special notice that this permit includes an effluent limit for Total Residual Chlorine, but this limit will not become effective until October 1,2006 (18 months following the effective date of the permit). If any parts, measurement frequencies or sampling requirements contained in this permit are unacceptable to you, you have the right to an adjudicatory hearing upon written request within thirty(30)days following receipt of this letter- This request must be in the form of a written petition, conforming to Chapter 150B of(lie North Carolina General Statutes,and filed with the Office of Administrative Hearings(6714 Mail Service Center,Raleigh,North Carolina 27699-6714). Unless such demand is made,this decision shall be final and binding. Please note that this permit is not transferable except after notice to the Division- The Division may require modification or revocation and reissuance of the permit. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Water Quality or permits required by the Division of Land Resources,the Coastal Area Management Act or any other Federal or Local governmental permit that may be required. If you have any questions concerning this permit, please contact Bob Sledge at telephone number(919) 733-5083,extension 547. Sincerely, ORIGINAL SIGNED BY SUSAN A. WILSON Alan W. Klimek,P.G. cc: Central Files Mooresville Regional Office/Surface Water Protection Section {NPDES Unit 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 One 512 N.Salisbury St.,Raleigh, North Carolina 27604 North Carolina Phone: 9 1 9-733-701 5 1 FAX 919.733.249611nternet::h2o,enr.state.nc.us An Equal OpportunitylAffinnative Action Employer-50%Recycled110%Post Consumer Paper ;Vaturally Permit NCO020052 STATE OF NORTH CAROLINA DEPARTMENT OF ENN71RONMENT AND NATURAL, RESOURCES DIVISION OF WATER QUALITY PERMIT TO DISCHARGE WASTEWATER UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYS7-F-I\4 In compliance urth the provision of North Carolina General Statute 143-215.1,other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission,and the Federal Water Pollution Control Act,as amended,the Town of McAdenville is hereby authorized to discharge wastewater from a facility located at the McAdenville WWTP Church Street Gaston County to receiving waters designated as the South Fork Catawba River in the Catawba River Basin in accordance with effluent limitations,monitoring requirements, and other conditions set forth in Parts I, II, III and IV hereof. 'I7iis permit shall become effective April 1, 2005. This permit and authorization to discharge shall expire at midnight on January 31, 2010. Signed this day March 3, 2005. ORIGINAL SIGNED BY SUSAN A. WILSON Alan ` , Klimek, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit NCO020052 SUPPLEMENT TO PERMIT COVER SHEET All previous NPDLS Permits issued to this facility,whether for operation or discharge are hereby revoked.As of this permit issuance,any previously issued permit hearing this number is no longer effective. 'Therefore, the exclusive authority to operate and discharge from this facility arises under the pernut conditions, requirements, ternis, and provisions included herein. The Town of McAdenville is hereby authorized to: 1_ Continue to operate an existing 0.13 MGD contact-stabilization wastewater treatment facility with the following components: ♦ Influent pump station ♦ Bar screen ♦ Grit chamber ♦ Contact aeration basin ♦ Reaeration basin ♦ Aerobic digester ♦ Clarifier ♦ Effluent disinfection ♦ Flow measuring device This facility is located at the McAdenville WWTP, at the end of Church Street in McAdenville in Gaston County. 2. Discharge from said treatment works at the location specified on the attached map into the South Fork Catawba River, classified CIS-V waters in the Catawba River Basin. Permit NCO020052 A. (1.) EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS During the period beginning on the effective date of this permit and lasting until expiration, the Perrnittee is authorized to discharge from outfall 001. Such discharges shall be limited and monitored by the Permittee as specified below: I~f=FLUEHT ors 'LIMITS .' MONITORING REQUIREMENTS, { CHARACTERISTICS Monthly `Weekly , (;daily Measurement Sample : Sarrtple Focation Average & vera a %Maxfmumu :'Fre uency , s Type T : 4, :r Y x•"= `; Flow 0.13 MGD Continuous Recording Influent or Effluent f30D,5-day(20°C)t 30.0 mglL 45.0 mglL Weekly Composite Influent and Effluent Total Suspended Solidsl 30.0 mglL 45.0 mglL Weekly Composite Influent and Effluent NH3 as N Weekly Composite Effluent Fecal Coliform 2001100 ml 4001100 ml Weekly Grab Effluent (geometric mean Total Residual Chlodne2 28 uglL 2/Week Grab Effluent Temperature(°C) Daily Grab Effluent: Total Nitrogen Quarterly Composite Effluent.. NO2+NO3+TKN Total Phosphorus Quarterly. Composite Effluent,,.,: pH3 Weekly Grab Effluent Footnotes: 1. The monthly average effluent BOD and-Total Suspended Residue concentrations shall not exceed 15%of the respective influent values (85%removal). 2. The limit wilt take effect on October 1,2006 (18 months after the effective date of the final permit). I The pH shall not be less than 6.0 standard units nor greater than 9.0 standard units. 'hltere shall be no discharge of floating solids or visible foam in other than trace amounts. vim WIN „ _ �.�-3�s_ ,i r _,Fs.:- F; `3" :-isyrf ,,F'. .... i y.t - - .� - •1 STATE 00 eVORrr1 �� ENVIRONMENTAL: MAN AFFIDAVIT OF INSERTION OF NPD S T°MMI '° 1617 MAIL SERVICE; ADVERTISEMENT CENTER RALEfGH,NC 27699-1617` The Gaston Gazette NOTIFICATION I A TENT TO ISSUU E A NPDES WASTEWATER PERMIT On the basis of thorough staff review and applica- tions of NC General Statute Gastonia, NC 143,21, Public law 92-5W and other lawful standards Gaston County and regulations, the North Carolina Environmental Management Commission' proposes to issue a Nation- al Pollutant Discharge I, Linda Seiboth Legal Advertising Clerk of The Gaston Gazette do certify that the Elimination System g c t y (NPDES) wastewater dis- advertlsement of charge permit to the per-Son(s) listed below effec- live 45 days from the pub- PUBLIC NOTICE lish date of this notice. Written comments regard- ENVIROI'lENTAL MANAGEMENT COMMISSION ing the proposed permit will be accepted until 30 days after the publish dale of this nodoe. All comments re- ceived prior to that date are de- Measuring10.14 Inches appeared in The Gaston Gazette a newspaper ublished in considered in the final the PP � p terminations regarding the Gaston County, Gastonia, NC, in issues: I proposed permit. The Di- rector of the NC Division of Water Quality may decide to hold n public meeting for the proposed permit should OCTOLBR:30 2004 the Division receive a sig- , s� h nificant degree of public in- . Copies .;�.-.__..._•-.__.. .. . -..-. _- _ ..__ . . .......�:_.�; /�� Copies of the draft permit and ottizr supporting infor- lVj U mation on file used to de- termine conditions present Linda Seiboth in the draft permit are avail- Legal Advertising able upon request and pay- IVO V 9 20�4 i ment of the costs of repro- duction. Mail comments and/or requests for infor- mation to the NC Division of Water Quality at the E�EF1R - W',:;TAT Ol;;t.LITY aladvi address or call Ms. Carolyn Bryant at (919) SWOrn.t dayof t {" 7 I 2004 733-5083, extension 520. 1 t i Please include the NPDES permit numoor NC0020052, in any com- munications. Interested _ persons may also visit the Division of Water Qualify at 512 N. Salisbury Street, Carla Norris Potter, Notar Public Raleigh, 27604-1148 y between thhee hours of 8:00 My Commission Expires September 14 2008 a.m,and on to review in- le. to on file. The Town of McAdenville S (100 Main Street, McAdenville, N.C. 28101), i has applied for renewal of ; NPDES Permit NCO020052 for the McAdenville WWTP in Gaston County. This fa- citify is permitted to dis- charge 0.13 MGO of treated wastewater to the South Fork Catawba River , in the Catawba River Ba- sin.Currently, total residual chlorine is water quality limited.This discharge may affect future allocations in this portion of the South Fork Catawba River. 1 C-October 30,2004 bt)b - 1. BOARD: n �j BOARD: u L Elizabeth M.Hagood y � i C Edwin H.Cooper,III Chairman Mark B.Kent Carl L Brazell Vice Chairman `- r . s[evcn.G. Kisner PROMOTE PROTECT PROSPER ' ':�•�•• L. Michael Blackmon Secretary C.Earl Hunter,Commissioner --__ _ Coleman.F.BuckhOLLse;;MI) Promoting and protecting the healtb of the pubfic and the envit Lg November 4, 2004 f bNOV �9 Ms. Carolyn Bryant ` NC Division of Water Quality _ r i ENR Environmental Management Commission/NPDES Unit °WATER QUAQYY PTNI SOURCF,Bj�A =t' 1617 Mail Service Center `�: `� Raleigh NC 27699-1617 RE: Notification of Intent to Renew a NPDES Wastewater Permit for Town of w McAdenville (NC0020052) dated October 27, 2004. Dear Ms. Bryant: We would like to submit comments on the above proposed NPDES permit renewal, which would continue the discharge of treated wastewater into the South Fork Catawba River. According to DHEC monitoring data, the Lake Wylie is impaired by copper levels above the Mill Creek arm at the end of road S-46-557. South Carolina's standard for copper is 2.9 ugll. In addition, Lake Wylie (Crowders Creek arm at SC highways 49 and 274) and the Catawba River (at South Carolina Highway 21) are impaired by fecal coliform bacteria. South Carolina's standards for fecal coliform in the Catawba River are "not to exceed a geometric mean of 2001100ml based on five day consecutive samples during any 30 day period; nor shall more than 10% of the total samples examined during any 30 day period exceed 4001100ml." Please ensure that any permitted activities will not contribute to violations of South Carolina standards. Thank you for considering these comments when reviewing, revising, and issuing this permit. If you need more information, please contact Mark Giffin at (803) 898-4203 or giffinma@dhec.sc.gov for assistance. Since eIy Kathy Stec er, Manager Watersheds and Planning Section MKS:MAG cc: Mark Giffin Rheta Geddings SOUTH CAROLINA DEPARTMENT OF HEALTH AND ENVIRONMENTAL CONTROL 2600 Bull Street 0 Columbia,SC 29201 • Phone.(803) 898-3432 • www.scdhec.gov t� NC®ENR North Carolina Department of Environment and Natural Resources RECCIV%jvision of Water Quality 11!lDOre5viilp Fly^lattai tmlce Michael F. Easley, Governor William G. Ross,Jr., Secretary OCT 2 8 2004 Alan W. Klimek, P.E., Director NCDENR October 26, 2004 Public Water Supply MEMORANDUM To: Britt Setzcr 4l NC DENR/ DEI-i / Regional Engineer Mooresville Regional Office "l S F NOV 8 200� From: Bob Sledge NPDES Unit AENR WA7Eat QUALITY POINT sOUFcl BRANCH Subject: Review of Draft NPDES Permit NCO020052 a �- Town of McAdenville WWTP Gaston County Please indicate below your agency s position or viewpoint on the draft permit and return this form by November 24,2004, If you have any questions on the draft permit, please contact me at the telephone number or e-mail address listed at the bottom of this page. RESPONS (Check one) Concur with the issuance of this permit provided the facility is operated and maintained properly, the stated effluent limits are met prior to discharge, and the discharge does not contravene the designated water quality standards. F-1 Concurs with issuance of the above permit,provided the following conditions are met: ❑ Opposes the issuance of the above permit,based on reasons stated below,or attached: Signed Date: 1617 Mail Service Center,Raleigh,North Carolina 27699-1617 One 512 N.Salisbury St.,Raleigh,North Carolina 27604 NorthCaro�ina Phone: 919-733-5083,extension 5471 FAX 91 9-733-991 9 1 Internet:h2o.enr.state.nc.us/NPDES bob.sledge@ncmail.net ;Vahtrally An Equal Opportunity/Affirmative Action Employer-50%Recycled110%Post Consumer Paper TRC Limit Calculation NCO020052 Total Residual Chlorine s7Q10 CFS 124 DESIGN FLOW MGD 0.13 DESIGN FLOW CFS 0.2015 STREAM STD UG/L 17.0 UPS BACKGROUND LEVEL g/L 0 IWC (%1 0.16 Allowable Concentration (fig/L) 10478.54 TRC standard requires limits of 17-28 pug/L 10/19/2004 SOC PRIORITY PROJECT: Yes—No X To: Permits and Engineering Unit Water Quality Section Attention: Carolyn Bryant Date: September 21, 2004 NPDES STAFF REPORT AND RECOMMENDATION County: Gaston MRO# 04-72 Permit No. NCO020052 n D PART I - GENERAL INFORMATION SEP 2 3 2004 1. Facility and address: Town of MacAdenville WWTP J 100 Main Street DENR - WATER QUALnY Statesville, North Carolina 28101 POINT SOURCE BRANCH 2. Date of investigation: September 8, 2004 3. Report prepared by: Samar Bou-Ghazale, Env. Engineer.1 4. Persons contacted and telephone number: Mr. Mike Church, ORC, (704) 823-23 10. 5. Directions to site: From the junction of Highway 7 (Main Street) and S.R. 2209 (Wesleyan Drive) in the Town of MacAdenville, travel south on S. R. 2209 approximately 0.3 mile and turn left onto Church Street(no S.R. number). The wastewater treatment plant is located at the end of Church Street. 6. Discharge point(s). List for all discharge points: Latitude: 35' 15' 20" Longitude: 80' 04' 22" Attach a U.S.G.S. map extract and indicate treatment facility site and discharge point on map. USGS Quad No.: F 14 SE USGS Name: Mount Holly, NC 7. Site size and expansion area consistent with application? Yes X No— If No, explain: 8. Topography(relationship to flood plain included): Facilities are not located in the 100-year flood plain. Slopes range from 1- 3%. 9. Location of nearest dwelling:No dwellings within 500 feet of the WWTP site. 10. Receiving stream or affected surface waters: South Fork Catawba River. a. Classification: WS-III b. River Basin and Subbasin No.: Catawba C. Describe receiving stream features and pertinent downstream uses: Receiving stream has substantial flow. Other wastewater dischargers are located above and below the subject point of discharge. PART II- DESCRIPTION OF DISCHARGE AND TREATMENT WORKS 1. a. Volume of wastewater to be permitted: 0.13 MGD (Ultimate Design Capacity) b. What is the current permitted capacity of the wastewater treatment facility? 0.13 MGD C. Actual treatment capacity of the current facility(current design capacity)? 0.13 MGD d. Date(s)and construction activities allowed by previous Authorizations to Construct issued in the previous two years: NIA. e. Please provide a description of existing or substantially constructed wastewater treatment facilities:The existing facility is a contact stabilization wastewater treatment plant consisting of bar screen, grit chamber, contact aeration basin, reaeration basin, aerobic digester, clarifier and chlorine tablet disinfection. £ Please provide a description of proposed wastewater treatment facilities: N/A. g. Possible toxic impacts to surface waters: Chlorine. h. Pretreatment Program(POTWs only): N/A. 2. Residuals handling and utilization/disposal scheme: Sludge generated at the Town's WWTP is transferred from the aerobic digester to the Pharr Yams Industrial WWTP where it mixed, dewatered and transported to the Gaston County landfill for final disposal. 3. Treatment plant classification(attach completed rating sheet):Class II(no change ofrating, no rating sheet attached). 4. SIC Code(s): 4952 Wastewater Code(s): 01 Main Treatment Unit Code: 09507 Page 2 1. is this facility being constructed with Construction Grant Funds or are any public monies involved(municipals only)?N/A. 2. Special monitoring or limitations(including toxicity) requests: None. 3. Important SOC, JOC or Compliance Schedule dates: NIA 4. Alternative Analysis Evaluation: (Has the facility evaluated all of the non-discharge options available. Please provide regional perspective for each option evaluated): NIA 5. Air quality and/or groundwater concerns or hazardous materials utilized at this facility that may impact water quality, air quality or groundwater? No known air quality, groundwater or hazardous materials concerns. PART IV-EVALUATION AND RECOMMENDATIONS The Permittee, The Town of McAdenville, is applying for renewal of the facility's NPDES permit to discharge treated domestic wastewater. The WWTP appeared to be well operated and maintained at the time of the site investigation. Pending review and approval by the P& E, it is recommended that the permit be renewed as requested. l Signature of Re reparer z , Water Quali egional Supervisor Date Page 3 r i 7 N-C- OW27 O TADENVILLE ►. t_��.�,:'- -- I NCO R r- O R A TE D 1 9 B 3 6Y THr- RIVER 100 MAIN STREET (704) 824-3551 McAOENVILLE, N.C. 28101 July 26, 2004 Ms. Valery Stephens NCDENR Division of Water Quality Point Source Branch 1617 Mail Service Center Raleigh,NC 27699-1617 Re: Town of McAdenville WWTP Modification and Renewal of NPDES Permit No. NCO020052 Gaston County,NC Dear Ms. Stephens: The Town.of McAdenville requests the renewal of the subject permit with an expiration date of January 31, 2005. Please find attached the original and two copies of this letter, the permit application, sludge management plan, and letters of information dated February 4 and December 12, 1992 regarding the polishing pond modification request. There have been no changes in the facility since the permit was last issued. However, future plans are to permanently close the old "polishing" pond-that was abandoned in 1992. This pond did not add additional treatment to the effluent of the WW'iP and will not be needed in the future. A modification of the permit to eliminate and close the "polishing" pond-is requested. The proper closure procedures will be followed and any remaining sludge will be disposed of in accordance with regulations. Please contact me at (704) 823-23 10 to advise of any other requirements that need to be submitted for the permit modification and renewal. Thank you for your assistance. Sincerely, �� J 7L4 Mike Church cc: Mayor Jerry Helton Town of McAdenville WWTP Sludge Management Plan Permit No. NCO020052 Gaston County Sludge from the Town of McAdenville WWTP aerobic digester is transferred by Septic Tank Truck to the Pharr Yarns WWTP (NC0004812) digester as needed. ' S IN CONTACT PLANT OUT B . Pumps via TE I t TO PIVEP - IN W TWELL - IN PC9-1 H114G SA �IN - C7 O U T = PIPING SCHEMATIC: [7iA.CR,slvl r— _ 1a=E F'FL 1-LF—N`L-FAO M 'P[=AtvT r ' f REV. NO. DESCRIPTION D1 bATE L': w �• d aaaau�uu,,,4 Producers bF Phut►YWM ss,�l� Moln ARM OMW.MGnasrft nc 237O1 FEq(�9 PLANT UNIT_ _ S L.AMM kN. T 4cL r' LOCATiON -T0 V 0E-M-A0 C N VILLc- I C.� 0 UM --- — SLIEE7J,oF 1 a�:kr�a'r R.ctit�``'� 1 ..— ;': Li• �. DRAWING ND. ` d SCi4LE:n1D11r� WTD7A'.Yf! �-5 DAif:jr4-QI APP. By I1 � FACT SHEET FOR EXPEDITED RENEWAL Permit Number hJC O 0�o 0 5- Facility Name YY?C f�d2n�r 11� (/J())-rP Reviewer Basin/Sub-basin 03 - 0g-3f�o Receiving Stream S a { }L [`c 1 b� 'i Lk Stream Classification in permit Stream Classification in BIMS Is the stream impaired (listed on 303(d))? Is stream monitoring required? tj 0 Do they need NH3 limit(s)? Do they need TRC limit(s)? Do they have whole-effluent toxicity testing? Are there special conditions? V Any obvious compliance concerns? p Existing Expiration Date I 3 4 OS Proposed Expiration Date Miscellaneous Comments: If expedited, is this a impler permit or a more difficult one?