HomeMy WebLinkAboutWQ0029307_Regional Office Historical File Pre 2018Michael F. Easley, Governor William G. Ross Jr„ Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, RE, Director Division of Water Quality September 13, 2005 Mr.Carl Palmer, Town Administrator Town of Harrisburg 4100 Main Street Harrisburg, NC 28075 Subject: Permit No. WQ0029307 Bridge Point Subdivision Town of Harrisburg Wastewater Collection System Extension Cabarrus County, North Carolina Dear Mr. Palmer: In accordance with your application received on August 24, 2005, we are forwarding herewith Permit No. WQ0029307, dated September 13, 2005, to the Town of Harrisburg for the construction and operation of the subject wastewater collection system extension. This permit shall be effective`from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein, This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. " Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Perrnittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Faittrre to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. aro tna uralily Mooresville Regional Office 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Internet h2o.enr.state.nc.us Customer Service: 1-877-623-6748 An Equal Opportunity/Aftinnative Action Employer - 50% Recycled/10% Post Consumer Paper VaigaMt/Mk . Mr, Carl Palmer Page 2 September 13, 2005 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the Town of Harrisburg for the construction and operation of approximately 3,540 linear feet of 8-inch gravity sewer, a 80 gallon per minute pump station (with duplex pumps, on site audible and visual high water alarms, and a portable generator receptacle), and approximately 5,352 linear feet of 4 inch force main as part of the Bridge Point Subdivision project; and the discharge of 33,480 gallons per day of collected domestic wastewater into the Water and Sewer Authority of Cabarrus County existing sewerage system, pursuant to the application received August 24, 2005, and inconformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Water and Sewer Authority of Cabarrus County WWTP (Rocky River Regional NPDES No. NC0036269) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. Sincerely, i?" for Alan W. Klimek, P.E. Cabarrus County Health Department Mooresville Regional Office, Surface Water Protection (WWTP Permit No. NC0036269) Anthony Cowan, The Isaacs Group P.C. Surface Water Protection Central Files Marie Doklovic.., PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The _sewer system shall, be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 21...0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. VATitjlali=4ala 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2H .0220, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this perrnit, 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as -may be required by this Division, such as the construction of additional or replacement facilities, 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Voice nail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 13th day of September, 2005. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Klimek, .E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0029307 Fast Track Engineering Certification Permit No. WQ0029307 September 13, 2005 Complete and submittsform to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION Partial Ej Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (El periodically, Elj weekly, D full time) the construction of the Bridge Point Subdivision, Cabarrus County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineers Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. FAST -TRACK APPLICATION for GRAVITY SEW PUMP ATIONS, AND FORCE MAINS PAGE 3 0 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! f. Owner: 1 a. Town of Harrisburg Full Legal Name (company, municipality, HOA, utility, etc. 1 b. Carl Parmer, Town Administrator Signing Official Name and Title (Please review 15 A g ...�M.- oA NCAC 2H .0206(b) for authorized signing o lc, The legal entity who will own this system is: ❑ Individual ❑ Federal Municipality ❑ State/County ❑ Private Partnership ❑ Corporation ❑ Other (speci Application Number: (to be completed by DWQ) 1 d. 4100 Main St, Street Address North Carolina Z State 0 1h, (704) 455-5614 Telephone ... i 2. Project (Facility) Information: 2a, Bridge Pointe Subdivision Facsimile Brief Project Name (permit will refer to this name 3. Contact Person: 3a, Anthony Brent Cowan, P.E Name and A ation of Someone Who Can Answer 3b. (704) 527-3440 ext. 12 Phone Number 1 e. Harrisbur City 1 g. 28075 Zip Code E-mail 2b. Cabarrus County Where Project is Located uestions About this Application 3c. bcowan@isaacsgrp.com E-mail 1. Project is ',i1! New ❑ Modification (of an existing permit) If Modification, Permit No.: For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another phase, changing line size/length, etc.). Only Include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2. Owner is ® Public (skip to Item B(3)) © Private (go to Item 2(a)) 2a. If private, applicant will be: 2b. If sold, facilities owned by a (mus • Retaining Ownership (i.e, store, church, single office, etc.) or ❑ Leasing units (lots, townhomes, etc. - skip to Item B(3)) Q Selling units (lots, townhomes, etc. - go to item B(2b)) Water and Sewer Authority of Cabarrus County (WSACC) © Public Utility (Instruction III) ❑ Homeowner Assoc./Developer (Instruction IV) Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project {.1C. 3,r Zh. a. Rocky River W astewater Treatment Plant 4b. op Name of WWTF WWTF Permit No. 5a. WSACC 5b. Owner of Downstream Sewer Receiving Sewer Size The origin of this wastewater i (check all that apply): Residential Subdivision 0 Apartments/Condominiums El Mobile Home Park ❑ School O Restaurant 0 Office ❑ Car Wash ❑ Institution ❑ Hospital ❑ Church 0 Nursing Home ❑ Other (specify): Permit Number of Downstream Sewer (if known Volume of wastewater to be permitted in this project: 20,520 gallons per day 100 % Domestic/Commercial % Industrial % Other (specify): If the permitted flow is zero, indicate why: 0 Interceptor Line - Flow will be permitted is subsequent permits that connect to this line O Flow has already been allocated in Permit No. ❑ Rehabilitation or replacement of existing sewer with no new flow expected FTA 02/03 - Rev. 1 06/03 FAST -TRACK A CATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(1)(1-2) must be approved prior to submittal of this application. Submit a separate request to the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H .0219(1)(3), Ph. 1 &2 = 57 lots x 360 gpd = 20,520 gal. per day Pump Station full buildout = 93 lots x 360 gpd = 33,480 gal. per day 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) 4" 81.1 Length (feet) 5,352 3,540 ENTER TOTAL LINE LENGTH IN MILES 1.684 11 Summary of Pump Stations to be Permitted (attach additional sheets as necessary) , ! Location ID Power Reliability Option (self chosen - as shown on Design Flow Operational Point (1- dual line feed; 2- permanent generator wIATS; 3- plans for cross-reference) (MGD) GPM @ TDH portable generator wltelemetry; 4-wet well storage) ' Z Site .084 80GPM @ 73.47TDH 3 & 4 Gravity or Force Main (use the pull down menu) Force Main Gravity w 12, Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force, Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H ,0200 as applicable'? Yes 0 No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested: SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13, Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? 0 Yes 0 No 0 N/A Sedimentation and Erosion Control Plan? X4 Yes 1 No 0 N/A Stormwater? E Yes 0 No 0 N/A FTA 02103 - Rev. 1 06/03 FA_ST-TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MA1NS PAGE 5 1, Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as, necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: Ej A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, LJ A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map (self chosen - as shown on Name of Waterbody Stream Waterbody map for cross-reference) Waterbody County River Basin Index Classification SITE Fuda Creek Cabarrus Yadkin 13-17-7-1 C Submit the 8.5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! 1. Applicant's Certification: , attest that this application for BRIDGE POINTE SUBDIVISION has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, ori certification in any application shall be guilty of a Chess 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. la, Signing Official SignatureDate 2. Professional Engineer's Certification: attest that this application for BRIDGE POINTE SUBDIVISION has been reviewed by me 0 and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation, 2a. Anthony Brent Cowan Professional Engineer Name 2b. The Isaacs Grou , P.C. Engineering Firm 2c. 8720 Red Oak Blvd., Ste, 420 Address 2d. Charlotte _2e. NC 2f. 28217 City State Zip 2g. (704)527-3440 2h. (704)527-8335 2i. bcowan@isaacsgrp.com Telephone Facsimile E-mail Seal, Signature & Date FTA 02/03 - Rev, 1 0 0 WQ0029307 Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations„ Pressure Sews Extensions Primary Reviewer' dee.brwdr Permitted Flow 3480 central Files APS 09! Permit Tracking li Status In review Version A Project Type New Project Permit Classicc en Individual perriilt Contact ffllcafion Facility Name Bridge Point Subdivision Location Address Owner Na e Town of Harrisburg ei Events stater col App Received 082/5i tivlties. Outf NUL Wat rbody Name aft. In Model d d issuance acill Regan Mooresville County Cabarrus y Contact Affiliation Owner Type Government - Municipal Owner Affiliation Martha Melvin PO Box 100 Harrisburg NC 28075 Public Notice Issue Effective Expir on Addeo Addition requested nform Lion received a Index Number Current class Subbasin PAY i C7 THE OF THE ISAACS GROUP, t N. „*NC 28217 -3440 NCDENR NC OD S90 in WACNOVIA BANK, N.A. 66-21-530 DATE WATER & SEWER AUTHORITY OF CAF3ARRUS COUNTY Mr. Cul Panuer Town Administrator Town of Harrisburg PO Box 100 Harrisburg, NC 28075 August 19, 2005 Subject: Flow Acceptance — Bridge Point Subdivision Phase 1 & 2 Dear Mr. Pamier: Office: 232 Davidson Hwy. Concor4, NC 28:027 Ma to: RO. Box 428 Concord NC 28026-04.28 Phone: 704,786, )783 Fax 704.795,15E4 This is in response to the Town's request for flow acceptance received 7/13/05. The additional information requested from the owner in order to process the request was received 8/16/05. The Water and Sewer Authority of Cabarrus County (WSACC) has or currently expects to be able to make available capacity at the Rocky River Regional Wastewater Treatment Plant and. appropriate sewer interceptors to transport and treat the domestic wastewater from the proposed Bridge Point Subdivision Phase 1 & .2 consisting of 57 residential lots, WSACC agrees to accept wastewater from the proposed sewer line based on information provided by The Isaacs Group, P.C. (Civil Engineer for the project) using North Carolina Department of Environment and Natural Resources (NCDENR) wastewater flow guidelines. The projected flow is 20,520 gpd; however WSACC expects the actual wastewater flow to more closely approximate 14,250 gpd based upon Master Plan engineering data. The Town of Harrisburg understands that separate FloAcceptance Requests will be required for the future flows that will connect into this sewer line. By requesting flow acceptance, the Town of Harrisburg acknowledges that WSACC may need to upgrade, expand, or construct new facilities to accommodate the increased flow volume granted by this and previous flow acceptance. Appropriate design and construction will be initiated when actual flows dictate but :may be subject to situations that WSACC does not expect or control. Based upon flow of 20,520 gpd and cost of $8.126/gpd to provide treatment and transportation capacity, this flow acceptance represents an estimated capital expenditure in excess of $166,745. For your information and based upon NCDENR wastewater flow guidelines, WSACC has approved 1,503,537 gallons of flow acceptance for the Town of Harrisburg from 1992 to present and 108,000 gallons of flow acceptance year-to-date including this request. Based upon the approved flow acceptances, WSACC has committed capacity valued in excess of $12,217,741for the Town. of Harrisburg since 1992 including $877,608 for this calendar year. Downstream facilities from the proposed project are scheduled in WSACC's current six year Capital Improvement Program (CIP) to increase available capacity. Projects on the CIP are subject to approval by WSACC's Board of Directors, support from local governing bodies, regulatory T'own of Flarrishurg Bridge Pointe SubdivIsion Phase 1 & 2 August 19, 2005 Page -2- approval, and funding availability. The following schedule of CIF delayed by unforeseen circumstances: • Back Creek Interceptor Parallel Phase 1. Scheduled completion • Fuda Creek Interceptor. Scheduled completion date: 2009 Since this sewer connection will be made directly to the WSACC Fuda Creek Interceptor, WSACC must be notified being made. Notification is to be made to Mark Lomax (704/786 Please note that if construction of this project is not started of this approval, the approval is rescinded and a second request Please notify WSACC, in writing, when construction of this project If you have any questions, please call inc at 704-786-1783. cc: WSACC Engineering Staff Todd Taylor, P.E./Harrisburg Brent Cowart, P.E./Isaacs Group Sincerely, projects is tentative and may be date; 2005. existing 12-inch section of the 48 hours prior to connection -1783). within two (2) years of the date and approval will be required, is initiated. Evander Rowell, P.E. Utility Systems Engineer PUMP�U�U�� ^�� CALCULATIONS =°"��""*�"~ `�^��~~~~~=�"�~=°°=° Force main highest elevation = PROJECT Bridge pointeSubdivision Pb.-1 DATE: 7-Ju|405 Number ofunits = Unit Flow (gpd)= Additional flow Total Flow (8pd),(gpnm)= Req'dPump Capacity (gpd).(gpm)= Actual Design Pumping Rate (gpm) Diameter nYWet Well 08= Vo|unleVVVV per foot (ot/ft), (o/ft) = Storage Depth (ft)= Storage Volume (cD.(ga|)= Fill Time for Storage Depth (min)= Run time for Storage Depth (min) = Total Cycle time (min)= Pump Cycles/ hr= Dynamic Head Loss: Pump Elevation = Force K4o|n Equivalent Length (f) = Force Main Diameter (in) = Velocity in FKAadpump nate(ft/s)= Hazmn'VVU|iams'C'= Head loss FM/ 1QQ`at pump rate (ft)= Total Static Head (ft)= Dynamic Head at actual pumping nab*(ft) = Total Dynamic Head = Wet Well/ Switch Elevations: Rim Elevation = Lowest Gravity Sewer Inlet Invert = High water alarm e>ev. = Lag pump onelev. = Lead pump on e[ev.= Pumps off elev. = Bottom wet well elev.Depth of Wet Well = = IN � =No Additional units 33480.0 233=Nn.Unds°undhnvv+addhona|flow 50.24 58100 64%2.4O 2.04 140^00 0'44 45.45 28.02 73.47 600 588.00 585.50 584.50 58100 10.50 375.8 =1h°3.14°U^2/4 375�8= Storage Depth ^Vnume/h = Storage Volump/Tuto| avg. flow = Storage Volume/ (Pump Rate - Total flow) = Fill time + Run time =6U7[ntal Cycle time =FornwMain Length~1.2 =gprn°UAO8/D^2 For type pipe =FMElev.'PumpEkev = Force Main Length/10O°Head Loss = Static Head + Dynamic Head = |nvertolev. - 1.3' = Alarm elev. -0lX0' = Lag elev. 'O.5' = Lead elev. - Storage Depth = Pump Elev. = Pump e|ev.- 1.5' 04129-P0M9CALCS.Xle ation Force main profile Air release valves Cover over force mein Valve pit Static Head (ft) est Alarm Wetwell vented n Site Generator Automatic Transfer ritch Wet well depth (ft) ProjectedRow: Average daily flow (gpm) Required pump rate (2.5:1) Design pump rate (gpm) Wetwell Detention, Storage Volume (gal) Pump Rate (gem) Average inflow rate (gpm) Fill time (min) Pump time (min) Cycle time (rain} Cycles per hour pn TDH: Force main highest elevation Pump elevation Force main diameter (in) Force main length (ft) Head Lossll00 Velocity (ftls) C value (DI:125, PVC:140, HOPE ;14 ) Dynamic Head (ft) Total Dynamic Head (ft) Gravity tie in rim Gravity tie in invert Pump Selection: Grinder Pump YES NO 3' MIN. YES 45.45 Audible and Visibly:" YES YES YES 10.50 23,25 53,13 80.00 375,80 80,00 23.25 16.16 6,62 22.79 2.63 HOMA TP53M 5 Hp Submersible non -clog pump (Or Approved Equivalent) 80.0 gpm Adjustable Hoist Duplex Alternating Cycle Power Requirement 2,04 28.02 73,47 557.35 552. 60 73.47 TDH NO NO YES YES 4 0v, 3 Phase 04129-1PU :AL , l Bouyancy: Assume total soil saturation. Well Diameter (ft) .t well Depth (ft) idth of Anti -flotation collar (ft) Area of Anti -flotation collar (ft) Depth of Anti -flotation collar (ft) Vol, ofAnti-flotation collar (cf) = Vol. '. Water Displaced (cf), Buoyant force (lb) = Counter Bouyancy: Unit Wt. Concrete (lb lcf) = Unit''«t, Saturated Soil (lbs/cf) Width of Anti -flotation collar (ft) = Vol. Concrete (cf) Vol. Earth on Anti -flotation collar (cf Anti Floatation (lb) Safety Factor 8,0 10.50 78,54 0.67 5.6 745.46 46516.f34 1,0 282 335 65813 1 041 v U PCALC x1 August 22, 2005 Mrs, Sonja Basinger Division of Water Quality 919 North Main Street Mooresville, North Carolina 28115 Subject: Bridge Pointe Subdivision, Phase 1 & 2 Sanitary Sewer System Extension Harrisburg, North Carolina Dear Mrs. Basinger: We are enclosing per your requirements, the original and one (1) copy of the Fast -Track Application for Gravity Sewers, Pump Stations and Force Mains. Also included are two (2) copies of the flow acceptance letter from the Water and Sewer Authority of Cabarrus County (WSACC) agreeing to transport and treat the wastewater. A check for $400 has been provided for the application fee. If you have any questions concerning this project, please feel free to contact us, Sincerely, Todd Taylor, P. Town Engineer Enc Cc Brent Cowan, P.E., The Issacs Group Central Files; APS SWP___ 09/13/05 Permit Number WQ0029307 Permit Tracking Slip Program Category Non -discharge Status Project Type In review New Project Permit Type Version Gravity Sewer Extension, Pump Stations, & Pressure Sewer A Extensions Primary Reviewer dee.browder Permitted Flow 33480 Facility Facility Name Bridge Point Subdivision Location Address Owner Permit Classification Individual Permit Contact Affiliation Major/Minor Region Minor Mooresville County Cabarrus Facility Contact Affiliation Owner Name Owner Type Town of Harrisburg Government - Municipal Qates/Fvents Scheduled frig issue App Received Draft Initiated Issuance 08/24/05 Rectulated Activities Owner Affiliation Martha Melvin PO Box 100 Harrisburg Public Notice Issue Subdivision Wastewater collection Outfall NULL. NC 28075 Effective Expiration Additional information requested Additional information received Waterbody Name Stream Index Number Current Class Subbasin