Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0024255_Regional Office Historical File Pre 2018
Mr. Wilmer Melton, Public Works Director City of Kannapolis 1401 Bethpage Road Kannapolis, North Carolina 28081 Dear Melton: North Carolina Duportmcn1 of Env August 20, 2004 Micuiet F I 'vern off William G. Ross Jr., Sec FIN ffilly and Natural Resources Alan W. Klinlek.,. E. Director Division or Wetter Quality Subject: Permit No. WQ0024255 City of Kannapolis Shiloh Farms Sewer Extension Wastewater Collection System Extension Cabarrus County, North Carolina In accordance with your application received on August 9, 2004, we are forwarding herewith Permit No. WQ0024255, dated August 20, 2004, to the City of Kannapolis for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference, Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permiftee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1)15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board, Mooresville .Regional Office 919 North Main Street Mooresville., NC 281 I.5 Internet h2o,entstate.ncus Customer Service: 1-877-623-6748 An Equal Opportur1tylAffirmatiye Acton Employer-- 50% Recycled/10% Post Consumer Paper Phone: (704) 663-1699 Fax: (704) 663-6)W NDoTil)Caroliriq ,Naturally MrWrImer Melton Page 2 August 20, 2004 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Kannapolis for the construction and operation of approximately 3,342 linear feet of 24-inch gravity sewer to serve as a interceptor line as part of the Shiloh Farms Sewer Extension project, with no additional discharge of collected domestic wastewater (flow will be permitted in subsequent permits that connect to this line) into the Water and Sewer Authority of Cabarrus County's (WSACC) existing sewerage system, pursuant to the application received August 9, 2004, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in WSACC's Rocky River VVVVTP (NPDES No. NC0036269) prior to being discharged into the receiving stream. This permit shall become voidable unless the agreement between the City of Kannapolis and WSACC for the collection and final treatment of wastewater is in full force and effect, if any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Sonja Williams at (704) 663-1699. Sincerely, for Alan \AL Klimek, P.E. cc: Cabarrus County Health Department Mooresville Regional Office, Water Quality Section (WWTF Permit No. NC0036269) Andrew Deal, Meade Gunnell Engineering & Surveying, PC Water Quality Central Files NDPU Files NORTH CAROLINA ENVIRONMENTAL, MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit: 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3, The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227, If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained, c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (Le. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C, 4, This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Upon completion of construction and prior to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings," and one copy of the supporting design calculations to the North Carolina Department of Environment and Natural Resources, Water Quality, 919 North Main Street, Mooresville, N.C. 28115. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8, Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track. Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement. facilities,. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Perrnittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733- 3300. Persons reporting any of the above occurrences shall file a spill report by completing Part 1 of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur, Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 20th day of August, 2004. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Klimek, PDirector Division of Water Quality By Authority of the Environmental Management Commission Permit Number W00024255 Fa Track Enqineerina Ce Permit No. W00024255 August 20, 2004 on Complete and submit this form to the permit issuing regional office with the following' • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form, Permit modifications are re " ed for any chanqes resultin in non-cornDliance with this e ulations or minimum design criteria, This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION Partial El Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (0 periodically, [:::] weekly, Ei full time) the construction of the Shiloh Farms Sewer Extension, Cabarrus County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials, North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE 919 N. MAIN STREET MOORESVILLE NC 28115 ATTN: DEE BROWDER The Permittee is responsible for tracking all partial certifications up until a final certification is received, Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. CK. APPLICATION for GRAVITY SEWERS, PUMP STATIONS, ..AN FORCE MAINS PAGE 3 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Application Number: (to be completed by DWQ) W61.00 2,4 2 5 5 1 Owner la. Cityof Kannapolis Full Legal Name (company, municipality, HOA, utility, etc.) lb. Wilmer Melton, Director Public Works 0 Signing Official Name and Title (Please revew 5A NCAC 2H .02 (b) ffor authorized signing officials? i— ; 1 2 0 z 0 0 Q. eL z 0 z 2 re L1J th lc. The legal entity who will own this system is: 0 Individual 0 Federal Municipality 0 State/County 0 Private Partnership 0 Corporation 0 Other (specify): ld 1401 Beth a e Road Street Address NC State 1h. 704-920-4200 Telephone li 704-920-4244 Facsimile 2. Project (Facility) Information: 2a Brief Project Name (permit refer this n 3. Contact Person: AnrwD311 Project Engineer Name and Affiliation of Someone Who Can Answer Questions About this Application 3b 7Qyj4 3c. ade_a 1@mea Phone Number 1 Project is E New 0 Modification (of an existing permit) If Modification, Permit No,: For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another phase, changing line size/length, etc). Only include the modified information in this pen -nit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2. Owner is E Public (skip to item 8(3)) 0 Private (go to Item 2(a)) 2a. If private, applicant will be: 2b. If sold, facilities owned by a (must choose ane) e. Kannapolis City 1 g. 28081 Zip Code lj wrneltorici.kanna olis nc us E-mail 2b., El Retaining Ownership (i.e. store, church, single office, etc.) or 0 Leasing units (lots, townhomes, etc, - skip to item 8(3)) 0 Selling units (lots, townhomes, etc. - go to Item B(2b)) oUnty Where Project ed OM 0 Public Utility (Instruction III) 0 Homeowner Assoc./Developer (Instruction IV) 3. Water and Sewer Authoriabarrus County Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 4a. RockyRejRionaIWaste Water Treatment Plant 4b. NC0036269 Name of WWTF WWTF Permit No. 5a c\ISACC1 5b. fi 1' 5c. Owner of Downstream Sewer Receiving Sewer Size Permit Number of Downstream Sewer 6. The origin of this wastewater is (check ail that apply). O Residential Subdivision 0 Apartments/Condominiums Ej Mobile Home Park El School 0 Restaurant O Office Car Wash El Institution O Hospital 0 Church 0 Nursing Home Other (specify): 7. Volume of wastewater to be permitted in this project: 0 gallons pei. day known) 1 0 0 % Domestic/Commercial 8. If the permitted flow is zero, indicate why: J Interceptor Line - Flow will be permitted is subsequent permits that canoect to this line 0 Flow has already been allocated in Permit No. 0 Rehabilitation or replacement of existing sewer with no new flow expected % Industrial % Other (specify): 1TA 02{03 - „ )6/03 z CR APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 9_ Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H C1219(I) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than. that in 15A NCAC 2H .0219(1)(1-2) must be approved prior to submittal of this application. Submit a separate request to the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H .0219(I)(3). 10, Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) 24 3342 ENTER TOTAL LINE LENGTH IN MILES 0 , 6 3 smiles Gravity or Force Main (use the pull down menu) Gravity, 1. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID Power Reliability Option (self chosen - as shown on Design Flow Operational Point (1- dual line feed; 2- permanent generator plans for cross-reference) (MGD) GPM @ TDH portable generator witelemetry; 4-wet wel NIA ATS; 3- torage) 2, Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H M200 as applicable? LI Yes © No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested, See Attachment SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13, Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? 1 Yes D No Q N/A Sedimentation and Erosion Control Plan? E Yes El No © N/A Stormwater? © Yes LI No 3 NIA 1 TA dl'2� RACK APPLICAT1ON for GRAVITY SE '4 ER , PUMP STATIONS, AND FORCE MAINS PAGE 5 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02103 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality Z regional office (see instructions for addresses) OR indicate the following;. 9 0 A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, ❑ A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. 0 Location ID on Map (self chosen • as shown on Name of Waterbody Stream Waterbody map for cross-reference) Waterbody County Rover Basin Index Classification 1 Rocky River Cabarrus Yadkin 1 3-1 7 C Submit the '8.5"" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! Applicant"s Certification: 1, Wilmer Melton, Ill, Dtr, Public Wor ks, attest that this application for Shiloh Farms Sewer has �een reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note.` In accordance with North Carolina General Statutes 143-215.6A and 143-215, 68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10, 000 as arell as cllpenalties up to $25,0O0 per violation. -Ott Date I attest that this application for Shiloh Farms Sewer EticA been reviewed by me and is accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers gate, complete adopted February include a fine not to and consistent with the infomiation it7 the engineering plans, calculations, and all other supporting documentation to the best of my knowledge, I further attest that to the best of my knowledge the proposed design has been representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may prepared in 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force ns adopted June (1�. e date S gning Official Signature Professional Engineer's Certification: 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developE...d by other professionals, inclusion of these materials under my Address Professional Engineer Name Engineering Firm City Telephone Facsimile 2e, Zip SeaL Si re and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design, accordance with NC General Statutes143-2156A and 143-215,6B, any person who knowingly makes Note: In y false statement, exceed $10,000 as well as civil penalties up to $25,000 per violation. _one - The 7eb's Topographic Map 0 0.1 0.2 0.3 0.4 0.5 km 0 0.1. 0.2 0.3 0.4 0. Page Map center is UTM 17 523065E 3922187N (WGS84/NAD83) Kannapolis quadrangle. 7, '187 Projection is UTM Zone 17 NAD83 Datum GL-0.147 htir:flwww,u-Tozone,cornfprinLasp?7=17&TF--39"22187,00009352.3065&s=2:4&size=1 6,c9'''20n4 Permit Nuer WVQ0024255 Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Extensions Primary Reviewer sonja.williams Permitted Flow 0 Facili Fast Track ions, & Pressure Sewer Facility Name Shiloh Farms Sewer Extension Location Address Owner 08120/04 Per frii' Tracking Slip Status Protect Type In review New Project Version Permit Classification Individual Permit Contact Affiliation Owner Name City of Kannapolis Dates/Events inor Region or Mooresville County Cabarrus Facility Contact Affiliation Scheduled Orin Issue App Received Draft initiated issuance 08/09/04 Regulated Activities Commercial or industrial, other Domestic, other Wastewater collection Outfall NULL Waterbvdy Name Owner Type Government Municipal Owner Affiliation Melvin Rape, PE PO Box 1199 Kannapolis NC 280811199 Public. Notice is u Effective gig/ zo/a 4- Requested/Received Even Additional information requested Additional information received Stream lrrdex Number Expiration Current Class Subbasin SHILOH FARMS INC. 12,OT ODELL SCHOOL ROAD CONCORD, NC 29027 PAY TO THE ORDER OF Cabarrus Bank & Trust Ciun N.,C,28C25 MEMO 40 5 3 21 1,000 20 2 3 31111 O DATE 4-'6" L?RS t 6, 2004 04501-11 NC Div of Environmental Management Department of Environment and Natural Rest urces - Division of Watt .tr Qua] 919 N Main Street Mooresville, North Carolina 2S1 15 Re: Uighway 73 Rocky River Sewer Extension City of Kannapohs - Cabarrus County Dear Sir or Madam:. 2004 ANo NATURAL U�n,�, k . —SOURCES �'e4 c y m t 4,x ` { �'"� �� RpC''S �S ' $ N' $AL„ OFF C'J. Please find attached for your review and apla�:rova] the. original and one e�apy° o � �tc�il application, and a check for S400.00 for the processing fee. The City of Kannapolis Standard Specifications for Wastewater Collections Systems were approved by your office on August 11, 1993 and are being maintained by the Division of Environmental Management. New Water & Sewer Authority of Cabarrus County Standard Specifications were submitted January 2001, for review and approval. This project will be installed in accordance with these Standard Specifications. at 704-935-1519 Sincerely, Stephen J. Kissinger, PE Assistant City Engineer 04501-1 1 Hwy ester permit letter.dvc 'ou have any questions. langir eeri itb% 'V 704.938,150 1.A.;5 1htnt¢ta1?olls fit.; 28082-1248 I20 5. Main tit. Kan.: 1 04,intii 6810