Loading...
HomeMy WebLinkAboutWQ0024032_Regional Office Historical File Pre 2018Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, RE., Director Division of Water Quality Coleen H. Sullins, Deputy Director Division of Water Quality June 28, 2004 Mr. Carey Gartner, Maintenance Superintendent Perdue Farms, Inc, 862 Harris Street NW Concord, North Carolina 28025 Subject: Permit No, WQ0024032 Perdue Fan-ns, Inc. Perdue Farms Expansion Wastewater Collection System Extension Cabarrus County, North Carolina Dear Mr, Cartner, In accordance with your application received on June 11, 2004, we are forwarding herewith Permit No. WQ0024032, dated June 28, 2004, to Perdue Farms, Inc. for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and snail be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H 0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1)15A NCAC 2H ,0200 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215,6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 919 N, Main Street, Mooresville, NC 28115 Internet http://h2o.enrstate,nc.usi Telephone (704) 663-1699 Fax (704) 663-6040 DENR Customer Service Center Telephone 1 877 623-6748 Mr, Carey Cartner Page 2 June 28, 2004 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Perdue Farms, Inc. for the construction and operation of approximately 381.25 linear feet of 8-inch gravity sewer and approximately 214.24 linear feet of 6-inch gravity sewer to serve a freezer as part of the Perdue Farms Expansion project, and the discharge of 100 gallons per day of collected domestic wastewater into the City of Concord's existing sewerage system, pursuant to the application received June 11, 2004, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Water and Sewer Authority of Cabarrus County's (WSACC) Rocky River WWTP (NPDES No. NC0036269) prior to being discharged into the receiving stream. This permit shall become voidable unless the agreement between Perdue Farms, Inc., the City of Concord and WSACC for collection and final treatment of wastewater is in full force and effect. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714, Unless such demands are made, this permit shall be final and binding. If you need additional inforrnation concerning this rnatter, please contact Sonja Willia s at (704) 663-1699. Sincerely, ;JD , for Alan W. KIimek, P.E. cc: Cabarrus County Health Department Mooresville Regional Office, Water Quality Section (WWTF Permit No, NC0036269) Jill Brim, Concord Engineering & Surveying, Inc. Water Quality Central Files NDPU Files NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance un i rescinded and shall be subject to the following specified conditions and lirnitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable: and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3, The wastewater collection facilities shall be properly maintained and operated at ail times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC a .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and Maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C, 4, This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State, 6. Upon completion of construction and prior to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings," and one copy of the supporting design calculations to the Department of Environment and Natural Resources, Division of Water Quality, 919 North Main Street, Mooresville, N.C. 28115, 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collectiorrfacilities, 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and feqpral) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 2 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility, Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733- 3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 28th day of June, 2004, NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Klimek, ,E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0024032 Fast Track Engineering Certification Permit No. WQ0024032 June 28, 2004 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the record drawings or in written summary form, Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria, Thsiorciecr snati nctt consicerec coninciete nor .3ilowec to erneinUi r5 Engineers Certification and ati crens',_47porttng :r,ccurrentatiori nave tin receiverti tine Orvision Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION El Partial 1:1 Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (0 periodicaily, 0 weekly, 0 full time) the construction of the Perdue Farms Expansion, Cabarrus County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit, 15A NCAC 2H :0200: the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable: the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting rnaterials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS WATER QUALITY MOORESVILLE REGIONAL OFFICE 919 N. MAIN STREET MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. PAGE 1 CATION for GRAVITY SE&'I+'ERS, PUMP STATIONS, AND FORCE MAINS USE THE TAB KEY TO MOVE FROM FIELD TO FIELD Owner: Perdue Farms In Full Legal Name (company, municipality, HOA, utility, etc. Carey Cartner, Maintenance Superintendent Application Number: �, f (to be completed by DWQ) W Ql 4- b Signing Official Name and Title (Please review 15A NCAC 2H .4206(b) for authorized signing officialsi) The legal entity who will own this system is: Individual ❑ Federal E Municipality ❑ State/County © Private Partnership Corporation 0 Other (specify): 862 Harris St NW Street Address City 1 e. Concord NC lg. 28025 State 704-789-2.413 Telephone Project (Facility) Perdue Farrns Expansion ation: Brief Project. Name (permit Contact Person: as Jill M, Brim Facsimile o this name Zip Code E-mail 2b. Cabarrus County Where Project is Located Name and Affiliation of Someone Who Can Answer Questions About this Application 704.786-5404 3c. jillbrim@concordengineering.com Phone Number E-mail Project is New ❑ Modification (of an existing permit) If Modification,, Permit No.: 2. Owner is ❑ Public (skip to Item 8(3)) I Private (go to Item 2(a)) f private, applicant will be: 2b. If sold, facilities owned by a (must choose ne Retaining Ownership (i,e, store, church, single office, etc.) ❑ Leasing units (lots, townhomes, etc. - skip to Item 8(3)) 0 Selling units (lots, townhomes, etc. - go to Item 13(2b)) Water & Authori of Cabarrus Count WSACC astewater Treatment Facility (WWTF) Treating Rocky R. Wastewater Treatment Plant Name of WWTF City of Concord I5b. 8" Owner of Downstream Sewer J Receiving Sewer The origin of this wastewater is (check all that apply): Residential Subdivision • Apartments/Condominiums Mobile Home Park ❑ School O Restaurant Office Public Utility (Instruction Ill) ❑ Homeowner Assoc./Developer (Instruction IV) ewater From This Project 4b. NC00362, WWTF Permit No. 'JOT tci wri Permit Number of Downstream Sewer ❑ Car Wash 0 Institution ❑ Hospital 0 Church ,Nursing Home al ther (specify): t'CLZG f I 100 ©l© Domestic/Commercial 0 % Industrial % Other (specify): Volume of wastewater to be permitted in this project: 100 gallons per day If the permitted flow is zero, indicate why: Interceptor Line - Flow will be permitted is subsequent permits that connect to this line 0 Flow has already been allocated in Permit No. O Rehabilitation or replacement of existing sewer with no new flow expected FTA 02/03 R. APPLICATION f w GRAVITY SEWERS, PU STATIONS, Alwlii FORCE MAINS PAGE '2 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H M219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(I)(1-2) must be approved prior to submittal of this application. Submit a separate request to the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H .0219(1)(3). 4 employees/shift ' 25 gal/employee/shift = 100 gpd 0. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Length (feet) 381.25' 214.24' ENTER TOTAL LINE LENGTH IN MILES 0,112 Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID (as shown on plan Design Flow (MGD) Operational Point GPM @ TDH Gravity or Force Main (pull down menu) Gravity Gravity Gravity Gravity Gravity Gravity Gravity Power Reliability Option (dual line feed, permanent generator, portable generator, wet well storage) Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force- Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .020E as applicable? Yes © No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested: UBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? © Yes [] No N/A Sedimentation and Erosion Control Plan? ® Yes 0 No 0 N/A Stormwater? ® Yes © No Q N/A FTA 02/03 CK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 Use the Division's guidance document entitled, "'DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: A Watershed Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, A Watershed Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID Name of urn Map_ Waterbody, County River Basin 12 leil Waterbody Classification Submit the 8.5" x 11" topographic map as required in Instruction VI regardless of whether a classification is provided! Applicant's Certification: I attest that this application for Perdue Farms Expansion has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143- 215.6A and 143-215.68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signing Official Si Professional Engineer's Certification: I attest that this application for Perdue Farms Expansion has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. !' further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design.; Note: In accordance with NC General Statutes 143-215.6A and 143-215.68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. Jill M. Brim Professional Engineer Name b. Concord Engineering & Surveying, Inc Engineering Firm PO Box 268 Address 2d, Concord City 2e. NC 2f. 28026-026 State Zip g, 704-786-5404 2h. 704-786-7454 Telephone Facsimile iillbrim concordengineering.c Seat, Si nature [date �102/0 Permit Number Q0024032 Program Category Non -discharge Permit Type, Gravity Sewer Extension Pump Stations, Pressure , e + r Extensions Primary reviewer son a.willl ms Permitted Flow 100 Fac Facility Name Perdue Farms Expansion Perrt Status In review Version Per Tracking li Cant Priest Type New Project Permit Chassific individual et Affiliation flair rilWlinor Region Minor Mooresville cation Address County Cabaffus Facility Contect Affrliation Owner Q 116/04 Owner Name Perdue Farms Inc DatesiEvents Ong Issue Add r eceed 06/11/04 Regulated Activities Commercial or irtdhastr- Wastewater collection ttitle tl NE L aterbody°Nar thet Owner Type Non -Government Owner tfiliation Carey Cartrter, Maintenance 862 HarrisSt Nw i erirttendan Concord NC 28025 Scheduled nitiated Issuance Public Notice Issue Effective Requested/Received Events Andirons! information requested d �tadnal {r fca€trsatxr*r received Stream Index Number Current Class Expm Subbasin n 120'4,111:1-0,i*1-4, *maitiv,metktiftt9t,-1, CONCORD ENGINEERING AND 08-70 SURVEYING, INC. PI If 704-786-5404 & PH 332-9934 P 0 BOX 268 CONCOHD, NC 29026 PAY 10 THE °EIDE F coz4 :62-- '0 3 it / 0 ,t(„' 11.00023L000* 1:053/00 73?1: 0 Lf3000 fdd d, d'ddddd d« 3dVdd DOLLARS 23600 6i3-73/5:1i f MA/4C? i TopoZone - The Webs Topographic Map Pagel of I 0 0.3 0.6 0.9 1.2 1. km 0 0.2 0.4 0. 0.8 Map center is UTM 17 535766E 3920746N (WGS84/NAD83) Concord quadrangle Projection is UTM Zone 17 NAD83 Datum Hz-7.269 G=0.228 *'rt fwv,t,a4,,- p://www.topozone.com/print.asp7z-17&11-3920746.00009334&e-535766&s=50&size_ 3122/2004 45 Spring Street SW P.a. Box 268 Concord, NC 28026 Phone: (704) 786-5404 Fax: (704) 786-7454 Attention: WQ Supervisor Company: Address: Phone #: NCDENR 919 N Main St Mooresville, NC 28'#'15 704-663-1699 Concord Engineering Surveying, Inc. From: Michael Gee Date: 9 June 2004 Job #: 931011.010 CC: Re: Perdue Farms Freezer Addition 0 As Requested X For Approval 0 Sign and Return 0 For Review and Comment Copies Date No. ption Ff'A t02103- RE' ISED Check No, 23600 in the amount of $400.(X) (four hundred) WSCA 10/99 ; Acceptance Letter USGS "Tar 2 Entity Names http:/!! Cr�etarystate.nc.0 ns oskb/ ;ocp asp?46573 NC North Carolina Elaine F. Marshall DEPARTMENT OF THE Secretary SECRETARY OF STATE Po Box 29622 Raleigh, NC 27626-0622 (919)807-2225 Date: 611812004 Click here to: View Document Filings Print a pre -populated Annual Report Form I File an Annual Report Corporation Names Name Perdue Farms Incorporated Perdue Products Incorporated Perdue Foods Incorporated Business Corporation Information SOSID: Status: Date Formed: Citizenship: State of Inc.: Duration: Registered Agent Agent Name: Registered Office Address: Registered Mailing Address: Principal Office Address: Principal Mailing Address: Name Type Legal Prev Legal Prev Legal 0112170 Current -Active 8/1 /1983 Foreign MD Perpetual For ques C T Corporation System 225 Hillsborough Street Raleigh NC 27603 225 Hillsborough Street Raleigh NC 27603 PO Box 1537 Salisbury MD 21802-1537 PO Box 1537 Salisbury MD 21801-0000 or comments about the Forth Carolina Sere For questions or comments concerning the Corporations 0, Click 1 of 1 6/18/20it4 2:39 PM. Priv City of Concord Engineering Department Scott Padgett, Mayor W. Brian Hiatt, City Manager Paul D. Campbell, P.E., Director of Engineering May 11, 2004 Perdue Real Estate Holdings, Inc. 862 Harris St. NW Concord, NC 28025 Attn: Mr. Carey Cartner, Maintenance Superintendent a city meeting tbefuture... SUBJECT: CITY OF CONCORD WASTEWATER FLOW ACCEPTANCE Perdue Farms Expansion Harris Street Parcel. No. 562145-6098 Private Sanitary Sewer Extenston Dear Mr. Cartner: This letter is to confirm that on May 10, 2004 our office received the application package consisting of the engineering plans and specifications and on May 3, 2004,. the confirmation of the need for a private service extension, by Jill Brim, .NCPE, of Concord Engineering & Surveying, Inc.„ for the Perdue Farms Expansion Private Sanitary Sewer Service extension consisting of a approximately 381 linear feet of 8-inch sanitary sewer service other appurtenances located off of Harris Street to serve a commercialbuilding with an average industrial .flow of 100 GPD. It shall be the owner's responsibility to provide a cleanout on the private 8-inch sanitary sewer service that will be located within the inside edge of the public rights -of -way and to ensure that the design meets the criteria of the Water and Sewer Authority of Cabarrus County and the State of North Carolina. At this time, the City's downstream wastewater collection system has the capacity to accept the requested commercial flow. The City of Concord, however, wili not guarantee the acceptance of any future flow requests or changes in the nature of the flows associated with this private system. Pleasebe aware that the City will not assume any responsibility for the operation and maintenance of the subject private sewer system. The entity to whom the sewer extension permit is issued will be responsible for complying with North Carolina Administrative Code 15A NCAC 21-1 .0227. Please review this section of the Administrative Code prior to submitting your application to the State, If the permit applicant is unable to perform all of the operation and maintenance duties required by the State's Administrative Code, a private sewer extension should not be requested. Alfred M. Brown Operations Center C of G)ncorci a 850 Warren C. Coleman Btvd. P.O. Box 308 a Concord, North Quoin 28026 (704) 920-5425 a. :Fax (704) 7 8 6-4 52-1. TDD 1-8C-0-735-8262 A) Lin11,;(1.cmortbums The City reserves the right to disconnect the subject private extension from the City's wastewater collection system if improper operation and maintenance of the private system leads to sanitary sewer overflows within the City's wastewater collection system or violations of any ordinances or policy's. The City of Concord must be present to observe the connection of this private system to our public sewer infrastructure, in order to meet the Standard Specifications for Wastewater Collection and Water Distribution for Cabarrus County, Contact Phillip Kingsland, Construction. Administrator, at (704) 920-5404 at least 48 hours prior to the beginning of construction. The owner's engineer shall observe and certify that the private system has been installed in accordance with WSACC and State standards prior to the activation of the extension_ This letter shall not be construed as an Authorization to Construct by the City of Concord. All applicable permits associated with this project must be obtained and copies roust be presented on site prior to commencement of the work. Sincerely, Pail D. C2 Director of Engineering. Sincerely, CITY OF CONCORD T. Mark Fowler Director of Was water Department cc: Project No.: 2001- 029 Perdue Farms Expansion L Harris Street — Private San. Sewer Extension Jill Brim, NCPE, Concord Engineering & Surveying, Inc., P.O. Box 268, Concord, NC 28026 Mark Fowler, Wastewater Resources Department Paul Campbell, Director of Engineering WATER & SEWER AUTHORITY OF CADARRUS COUNTY May 14, 2004 W. Brian Hiatt City Manager City of Concord P. O. Box 308 Concord, NC 28026-0308 Subject: Flow Acceptance Perdue Farms Expansion at Harris Street Private Sewer Service Office: 232 Davidson Hwy. Concord, NC 28027 Maid to: PO. Box 428 Concord, NC 28026-0428 Phone: 704,786.1783 Fax: 704,795,1564 Dear Mr. Hiatt This is in response to the subject request for flow acceptance received 5/13/04. The Water and Sewer Authority of Cabarrus County (WSACC) has or currently expects to be able to make available capacity at the Rocky River Wastewater Treatment Plant and appropriate sewer interceptors to transport and treat the domestic wastewater from the proposed Perdue Farms office expansion accommodating four (4) additional employees. WSACC agrees to accept wastewater from the proposed office expansion project based on information provided by Concord Engineering & Surveying, Inc. (Civil Engineer for the project) using North Carolina Department of Environment and Natural Resources (NCDENR) wastewater flow guidelines. The projected flow is 100 gpd; however WSACC expects the actual wastewater flow to more closely approximate 80 god based upon Master Plan engineering data. By requesting flow acceptance, the City of Concord acknowledges that WSACC may need to upgrade, expand, or construct new facilities to accommodate the increased flow volume granted by this and previous flow acceptance. Appropriate design and construction will be initiated when actual flows dictate but may be subject to situations that WSACC does not expect or control. Based upon flow of 100 gpd and cost of $8.126/gpd to provide treatment and transportation capacity, this flow acceptance represents an estirnated capital expenditure in excess of $812. For your information and based upon NCDENR wastewater flow guidelines, WSACC has approved 11,685,326 gallons of flow acceptance for the City of Concord from 1992 to present and 207,830 gallons of flow acceptance year-to-date including this request. Based upon the approved flow acceptances WSACC has committed capacity valued in excess of $94,954,959 for the City of Concord since 1992 including $1,688,826 for this calendar year. Downstream facilities from the proposed project are scheduled in WSACC's current Capital Improvement Program (CIP) to increase available capacity. Projects on the CIP are subject to approval by WSACC's Board of Directors, support from local governing bodies, regulatory approval, and funding availability. The following schedule of CIP projects is tentative and may be delayed by unforeseen circumstances: • Rocky River Wastewater Treatment Plant phase II upgrade. Scheduled completion date: 2004. City of Concord Perdue P s — Private Se er Seriice May 14, 2004 Pae2f If construction of this project is not started thin . one year of the date of this approval, the approval is rescinded and a second request and approval will be required. Please neat, WSACCit writing when construction f this project is initiated. If you have any questions, please call me at (704) 786-1783, WSACC Engineering Sta Sherri Moore/Concord Jill M. Brim, P,PI I Sineer John C. Murdock, III Executive Director State of North Carolina Department of Environment and Natural Resources Division of Water Quality WATERSHED CLASSIFICATION ATTACHMENT Any changes made to this form will result in the application being returned. (THIS FORM MAY BE PHOTOCOPIED FOR USE AS AN ORIGINAL) APR 1 5 2004 INSTRUCTIONS: To determine the classification of the watershed(s) in which the subject project will be located, you are required to submit this form, with Items I through 8 completed, to the appropriate Division of Water Quality Regional Office Water Quality Supervisor (see Page 2 of 2) prior to submittal of the application .for review. At a minimum, you .must include an 8.5" by 11" copy of the portion of a 7.5-minute USGS Topographic Map that shows the surface waters immediately downslope of the project, You must identify the location of the project and the closest downsiope surface waters (waters for which you are requesting the classification) on the submitted reap copy. If the facility is located in the Neuse River Basin, also include a copy of the soil survey map for the project location, The corresponding non -discharge application may not be submitted until this form is completed by the appropriate regional office and included with the submittal. 1. Applicant's name (name of the municipality, corporation, individual, etc): Perdue Farms, Inc, Name and complete address of applicant: Perdue Farms,62 Harris St Concord .NC 5 City: Concord State:. NC Zip: 28025 Telephone number: ( 704)''789-2413 Facsimile number: ( 704 I 1. Project name (name of the subdivision, facility or establishinent,. etc.): Perdue Farms Expansion 4. County where project is located: Cabarrus 5. Name(s) of closest surface waters: Buffalo Creek 6. River basin(s) in which the project is located: , Yadkin River Basin 7. Topographic map name and date: Concord NC 1987. 8, North Carolina Professional Engineer's seal, signature, and date: TO: REGIONAL OFFICE WATER QUALITY SUPERVISOR Please provide me with the classification(s) of the surface waters,. watershed(s), these activities will occur, as identifiedon the attached map segment: Name(s) of surface waters and river basin(s): , —Rt./ A • Classification(s) (as established by the EMC): Proposed classification(s), if applicable: River basin buffer rules, if applicable: Signature of regional office personnel: and appropriate river basin(s) where Lfle4r1AI I 1,11 (.-4 55 C- 4.AIA FORM: WSCA 1.0/99 Page 1 of2 Michael F. Easley, Governor Wham G. Ross Jr., Secretary Nnrth Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality Coleen H. Sullins, Deputy Director Division of Water Quality May 28, 2004 CERTIFIED MAIL RETURN RECEIPT REQUESTED Mr. Carey Cartner, Maintenance Superintendant Perdue Real Estate Holdings, Inc. 862 Harris Street NW Concord, North Carolina 28025 Subject: Return of Permit Application Package Perdue Farms Expansion project Wastewater Collection System Extension Cabarrus County Dear Mr. Cartner: The Division of Water Quality's Mooresville Regional Office is unable to accept the enclosed application package (including fee) for review for the following reasons: •,/ Please provide the name of the corporation (Permittee) exactly as it is listed on the Articles of Incorporation with the NC Department of the Secretary of State. Upon searching the Corporations Database through the secretary of State's web site (http://www.secretarv.state.nc.us/Corporationsl, this office was unable to locate a registered corporation by the name of Perdue Real Estate Holdings, Inc. Please revise the application accordingly to reflect a registered corporation. .47 Items B(5a) + B(5c) have not been completed as is required by Section I, of the Application Instructions. Please note that the items listed above must be completed prior to resubmitting the permit application package (with fee) for approval. Your application is being returned as incomplete in accordance with 15A NCAC 2H .0208. The success of the fast -track approval process depends upon the receipt of complete and accurate applications. Please make the appropriate corrections and resubmit the application. The review process will then begin upon receipt of the completed and corrected application. Please be advised that construction and/or operation of wastewater collection system extension without a valid permit is a violation of North Carolina General Statute 143-215.1 and may subject the violator to appropriate enforcement actions in accordance with North Carolina General Statute 143- 215.6. Civil penalties of up to $25,000 per day per violation may be assessed for failure to secure a permit required by North Carolina General Statute 143-215.1 Mooresville Regiona' Office 919 N. Main Street, Mooresvilie NC 28115 DENR Customer Service Center An Equal Opportunity Action 7inployer Internet http://h2o,enrstate...nc.us/ Telephone (704) 663-1699 Fax (704) 663-6040 Telephone 1 800 623-7748 50% recycled/10% post-consurner paper Carey Gartner Page May 28, 2004 If you should have any questions arding the acceptance of your applicatin, please < < t me at (704) -1 . Thank you for your cooperation Enclosures(application check no. 23600) Sincerely, Sonja illi' Consultant Jill Brim, Concord Engineering & Surveying, in. PO :tx 268, n r, (no n°sures) FT Application return file AT.. Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, RE„ Director Division of Water Quality Coleen H, Sullins, Deputy Director Division of Water Quality May 28, 2004 CERTIFIED MAIL 100 5 ibso 066q OcE-75— 0—'7 RETURN RECEIPT REQUESTED Mr, Carey Cartner, Maintenance Superintendant Perdue Real Estate Holdings, Inc, 862 Harris Street NW Concord, North Carolina 28025 Subject Dear Mr, Cartner: Return of Permit Application Package Perdue Farms Expansion project Wastewater Collection System Extension Cabarrus County The Division of Water Quality's Mooresville Regional Office is unable to accept the enclosed application package (including fee) for review for the following reasons: Please provide the name of the corporation (Permittee) exactly as it is listed on the Articles of Incorporation with the NC Department of the Secretary of State. Upon searching the Corporations Database through the secretary of State's web site (http://www.secretarv.state.nc.us/Corporationsl this office was unable to locate a registered corporation by the name of Perdue Real Estate Holdings, Inc. Please revise the application accordingly to reflect a registered corporation. v Items B(5a) B(5c) have not been completed as is required by Section I. of the Application Instructions. Please note that the items listed above must be completed prior to resubmitting the permit application package (with fee) for approval. Your application is being returned as incomplete in accordance with 15A NCAC 2H .0208. The success of the fast -track approval process depends upon the receipt of complete and accurate applications. Please make the appropriate corrections and resubmit the application. The review process will then begin upon receipt of the completed and corrected application. Please be advised that construction and/or operation of wastewater collection system extension without a valid permit is a violation of North Carolina General Statute 143-215.1 and may subject the violator to appropriate enforcement actions in accordance with North Carolina General Statute 143- 215.6. Civil penalties of up to $25,000 per day per violation may be assessed for failure to secure a permit required by North Carolina General Statute 143-215.1. Mooresville Regional Office 919 N. Main Street, Mooresville, NC 28115 DENR Customer Servi-ce Center An Equal Opportunity Action Employer Internet http://h2orenr.state.nc.us/ Telephone (704) 663-1699 Fax (704) 663-6040 Telephone 1 800 623-7748 50% recycled/10% post -consumer paper \ Mr. Carey Gartner Page May 28 2004 if you should have any questions regarding the acceptance of your application, please contact me at (704) - 99. Thank you for your cooperation, Sincerely, Sonja Willierns Consultant Enclosures (application check no. 23600) cc: Jill Brim, Concord Engineering & Surveying, Inca PO Box 2es, Concord, s (no enclosures; FT Application return file