Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0023548_Regional Office Historical File Pre 2018
Robert D. Isenhour, Owner 206 Timberfield Trail China Grove, North Carolina 28023 Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, PE,, Director Division of Water Quality Coleen H. Sullins, Deputy Director Division of Water Quality February 17, 2004 Subject: Permit No. VVQ0023548 Robert D. Isenhour, Single Family Residence 4-Inch Sanitary Sewer Service to Serve 2567 Saddlewood Circle Wastewater Collection System Extension Cabarrus County, North Carolina Dear Mr. Isenhour: In accordance with your application received on February 3, 2004, and additional information received on February 17, 2004, we are forwarding herewith Permit No. WQ0023548, dated February 17, 2004, to Robert D. Isenhour for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein, This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Also note Condition 12 regarding a 4-inch gravity sewer line variance; and required easement agreement due no later than March 31, 2004. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1)15A NCAC 2H ,0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office Internet httpi/h2o,enr.state,ric„usi 919 N. Main Street, Mooresville, NC 28115 Telephone (704) 663-1599 Fax (704) 6,63-6040 DENR Customer Service Center Telephone 1 877 623,6748 Mr, Robert D. Isenhour Page 2 February 17, 2004 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Robert D. Isenhour for the construction and operation of approximately 73 linear feet of 4- inch gravity sewer to serve 1 four -bedroom residence as part of the 4-Inch Sanitary Sewer to Serve 2567 Saddlewood Circle project, and the discharge of 480 gallons per day of collected domestic wastewater into the Water and Sewer Authority of Cabarrus County's (WSACC) Rocky River WWTP (NPDES No. NC0036269) existing sewerage system, pursuant to the application received February 3, 2004, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast - Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall become voidable unless the agreement between Robert D. Isenhour, the City of Concord and WSACC for collection and final treatment of wastewater is in full force and effect, If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150E of North Carolina General Statutes, 276996714�ed with Unless h sucdemands ares smade this arings, 6714perrnit shall Mabe ! l Service Center, Raleigh, NC and binding. If you need additiona 663- infor tion concerning this matter, please contact Sonja Williams at (704) Sincerely, for Alan W. Klimek, P.E. cc: Cabarrus County Health Department Mooresville Regional Office, Water Quality Section (WWTF Pe Samuel King, King Engineering of Concord, Inc. Water Quality Central Files NDPU Files No. NC0036269) NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at ieast once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Upon completion of construction and prior to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings," and one copy of the supporting design calculations to the Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. 7, A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this pemlit; 15A NCAC 2H .0200; the, Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 2 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Ernergency Management at telephone number (800) 858-0368 or (919) 733- 3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur, Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. 12. The gravity sewer line serves a single family residence, A variance to use a 4-inch line instead of a 6-inch line is granted, No additional flow shall ever be connected to the line without first obtaining a permit from the Division. An easement agreement with location map shall be signed by each current property owner affected and be recorded in the Cabarrus County Register of Deeds Office no later than March 31, 2004. The easement agreement shall be attached to all property owners affected and run with the land. Failure to obtain and/or record the required easement by the timeframe above is a violation of this permit and may subject the Perrnittee to enforcement action or revocation of the subject permit. Permit issued this the 17th day of February, 2004. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Klimek, RE< Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0023548 Fast Track Engineering Certification Permit No. WQ0023548 February 17, 2004 Complete and submit this form to the permit issuing regional office with the following: One copy of the project record drawings (plan & profile views of sewer lines of the wastewater collection system extension supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the record drawings or in written summary form, Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division: Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION 0 Partial 0 Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (] periodically, weekly, El full time) the construction of the 4-Inch Sanitary Sewer to Serve 2567 Saddlevvood Circle, Cabarrus County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be but within substantial compliance of this permit; 15A NCAC :2 H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE 919 N. MAIN STREET MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. ot,,rGmm cw'V I V I'm^^km~,l,mINuVmm^III A«IN11 USE THE TAB KEY TOMOVE FROM F|ELDT0FkEU0! Application Number 2.Owner _is DPublic (skip k/Item B(�) tA4,Private (go Aa Item t� -' o� u.i_.'.. "p""*",.vpp/�umwovoer 2b Vsold, facilities owned Uya(mu st choose one) -- 9Retaining Ownership (i-o,store, ohUrCh. single office, otc)v, -- Public. Utility (Instruction U|) LJ Leasing units (lots, |mwnhomes, et:,- skip to ItomB(3' ^ / � Homeowner IV) � []DoUmgun�s8�o.,ownhmnex.e[c goboItem BpU�)~ . � ' 8 Water Sewer Authority nfCmhnxuaCOUC} E Owner c0Wastewater Treatment Feni|hy0WVVTF Treating Wastewater From 'This Project - ---------- ' 1, Owner, | 7aRobert � Full Legal Nome (company. munidpa|hy. HOA, ud|dy. etc,) �Z 1b� Robert D Isenhour / 0 Signing Qffioia|Name and Title (Please review 15ANCAC2H.020O(b)for -authorized signingoffir-ja/u!) -------' / 1u, | eo�ywho wiUown th�system is: � Odividua| LJ Federal [] Municipality State/County [] Private Partnership [] Corporation [] Other (specify): � 1d 2D8.Timbe'fielEiTrail 1e, China � 0 Street Address CityILL -- ------'--'----` Z/ ~� 1� North 1g 28023 --- ----- ---- -- ---' � - | ! State Zip Cone ------'--� � ' 1h. Telephone FeosnnilE ------ � 2, PAoj*ct(FeoWt: /nhxn7e .: -- 2a. 41Saohn dCircle 2b� GabarrUS,Prin� ' "°=`p="",will /"..x othis name) � Cont act b*o���nyon� ~ - o� NmnmendAffi|ahnnufSumonnoWhoCanAnswerQuestions ---'in ---- --�- --'--- nouv�/n ^pp/�anmn Jb 7O4�7 � 86'5464_-_. 3c. samkin m Phone Number ----- , project is JX New El Modification (of an existing permit) If Modification, Permit �No.: For modifications, attach mseparate sheet clearly explaining the reason for the modification (|^e adding another phase, changing line wizn8ength.etc.). Only include the modified kn(oonahoninthis permit application do not duplicate project information in B(7) and B(10-1 1) that has already been included in the original permit. a, Rock River Regional WVVTP - Name u� VVVVTFPermit No �� 5m� C��of<��!onnd �b� &^ ` -- - - - -- - / Own erofDownstream Sewer Receiving Sewer P�onhNuno � of ' -- - - / | Number m�n��eamSewer0/kno�n -~ 6� The origin ofthis wm�*watvr is (check all hut apply): ' - - '' ' Residential Subdivision Apartments/Condominiums Mobile Home Park School Restaurant UOffioe Car Wash El Institution �]Hospital LJChurch Nursing Home El Other (specify): VoIumeofwastewater tobmJpesrplb�qqinthis project: 400 gallons p*/day If the permitted flow is zem, indicate why, H6A Interceptor Line Flow will bapenniVediosubsequent permits that connect tnthis line LJ Flow has already been allocated in Permit No. Y6Dminestio/Commer�,-,,,il % Industrial �,,.,-,,,, 9 ,,c ni.INO, r 11H11V1V7,AIM lr 1'lltil: IVIAlINS PACE 1 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow .for line or pump station sizing if zero flow in the space below, Values other than that in 15A NCAC 2H .0219(I)(1-2) must be approved prior to submittal of this application, Submit a separate request. to the Division of Water Quality,. Non-Qisch;3rge Permitting Unit, 1617 Service Center, Raleigh, NC 27(399-1617 in accordance with 15A, NCAC 2H .0219(I)(:3). 4 bedroom residence © 120 gpdfbedroom = 480 gpd (73 If 4" pvc sanitary sewer service to serve one 4 bedroom residence) 10. Summary of Sewer Lines to be Perrnitaed (atta c:h additional sheets if necessary) Size (inches) Length (feet) 4 73 z H V ENTER TOTAL LINE LENGTH IN MILES 0 013 0 z Gravity or Force Main (Ilse the pull down menu) -Too' chi t. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) /1/ Location ID Power Reliability Option (self chosen - as shown on Design How Operational Point (1- dual line feed; 2- permanent generator w!ATS; 3- plans for cross-reference) (MGD) GPM @ TDH portable generator w/telernetry; 4-wet well storage) 12. Does the sewer system comply with theMinimum Design Criteria for the Fast Track Permitting of Pump Stations and Force_ Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? Yes No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested' Applicant is requesting a variance from minimum line size of 6" to 4', 4" is the rum tine size per City of Concord SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION Have the following pe rt fications been subrrarrtted for appro4a Wetland/Stream Crossings - General! Permit or 401 Certification? Sedimentation and Erosion Control Plan? Stormwater? [] Yes I] No [1JN/A Yes El No [1N/A Yes No A O20: Rev, 1 le A • At R. A, 11.4,,A, A kJ Ural. 0'1/A I 11A.."1‘,71, r ‘../110(-41. iN • 1 • Lise the Division's guidance document ertitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary), This document is available from our web site or by contacting the appropriate [Division of Water Quality Z regional office (see instructions for addresses) OR indicate the following: 2 0 U.. LIJ A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody. AND, El A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map (self chosen - as shown on map for cross-reference) x Name of Waterbody Tributary to Wolf VloarInkns County River Basin Cabarrus Yadkin Waterbody Stream Waterbody Index Classification 13-17-6-7 Submit the 8,5'x 11°' COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! Applicant's Certification: 0 t Robed D. Isenhour, attest that this application for 4" Sanitary Sewer Service to Sewn. 2567 Sadthewood Circie has been reviewed by me and is accurate and complete to tire hest of my kr?0w1ed9e 1 inderstrl that if all required parts of this application are not completed and that if all required supporting documentation and attachments are riot included, this application .package is subject to being returned as incomplete, Note,' In accordance with ,North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 civil pe alties up to $25,000 per violation. igning Official Signature 2. Professional Engineer's Certification: Date I attest that this application for 4 Sanitary Sewer Service to Serve 2567 Sadd/ewood Circle hits been reviewed by me and is accurate, complete and consistent with the information in the engineering plans. calculations, and all other supporting documentation to the best of my knowledge, I further attest that to the hest of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance, Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to he consistent with the proposed design. Note: in accordance with NC General Statutes 143-215,6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per viekation, 2a Sarnuel L. Professional Engineer Narne 211 King Engineerinpf Concord, Inc Engineering Firm 2c, Post Office Box 904 Address 2d, Concord 2e, NC 2f 28025 City State Zip 2g 7(14-786-5464 2h„ 704-788-6502 2i samkingfish aol.com_ Telephone Facsimile E-mail Seal, Signature & Date [TA 02103 - Rev. 1 0601 2 5', «t Mapped. edited and pu 9 shed §o/ a�SuwA PIP17 City of Concord Engineering Department Scott Padgett, Mayor W. Brian Hiatt, City Manager Paul D. Campbell, P.E., Director of Engineering Janua Mr. Robert D. Isenhour 206 Tiniberfield Trail China Grove, North Carolina 2.8023 0, 2004 a city reing thetue... SUBJECT: CITY OF CONCORD WASTEWATER FLOW ACCEPTANCE Robert D. Isenhour Parcel No. 5519-76-9398 Private Sanitary Sewer Extension Dear r. Isenhour: This letter as to confirm that on January 16., 2004 our office received the application package consisting of the engineering plans and specifications, as prepared and sealed by Samuel King, Jr.., NCPE, of the King Engineering of Concord, Inc., for the Robert. Isenhour Private Sanitary' Sewer Service extension consisting of a approximately 73 linear feet of 4-inch sanitary sewer service other appurtenances located off of Saddlewood Circle, SW to serve a private :residence for a total flow of 480 GPD. It shall. be the owner's responsibility to ensure that the design meets the criteria of the Water and Sewer Authority of Cabarrus County and the State of North Carolina. At this time, the City's downstream wastewater collection system has the capacity to accept the requested flow amount of 480 GPD. The City of Concord, however, will not guarantee the acceptance of any future Clow requests or changes in the nature of the flows associated with this private system. Please be aware that the City will not assume any responsibility for the operation and maintenance of the subject private sewer system. The entity to whom the sewer extension permit is issued will be responsible for complying with, North. Carolina. Administrative Code 15A NCAC 2H .0227. Please review this section of the Administrative Code prior to submitting your application to the State. If the permit applicant is unable to perform all of the operation and maintenance duties required by the State's Administrative Code, a private sewer extension should not be requested. The City reserves the right to disconnect the subject private extension from the City's wastewater collection. system if improper operation and maintenance of the private system leads to sanitary sewer overflows within the City's wastewater collection system or violations of any ordinances or policy's. Alfred M.. Brown Operations Center Croy of Cord .s 850 Waren C. Coleman. Blvd.. P.O, Box 308 4 26 7() 92(J 5425 4 Fax E 86-4521 TDD 1-K`-735-.8262 The City of Concord must be present to observe the connection of this private system to our public sewer infrastructure, in order to meet the Standard Specifications for Wastewater Collection and. Water Distribution for Cabarrus County. Contact Phillip Kingsland, Construction Administrator, at (704) 920-5404 at least 48 hours prior to the beginning of construction. The owner's engineer shall observe and certify that the private system has been instaled in accordance with WSACC and State standards prior to the activation of the extension. This letter shall not be construed as an Authorization to Construct by the City of Concord. All applicable permits associated with this project crust: be obtained and copies must be presented on site prior to commencement of the work. Sincerely, CITY OF CONCORD Paul D. Campbell Director of Engineering Sincerely,. CITY OF CONCORD T. Mark Fowler Director of Wastewater Department cc: Project No.: 2001- 029 Robert D. Isenhour — Private San. Sewer Extension Samuel King, Jr., N. C. P.E., KirrEngineering of Concord, Inc., P.O. Box 904, Concord, NC 280,26 Mark Fowler., Wastewater Resources Department Paul Campbell, Director of Engineering WATER & SEWER AUTHORITY OF CABARRUS COUNTY January 30.2004 W. Brian Hiatt City Manager City of Concord P. O. Box 308 Concord, NC 28026-0308 Subject: Flow Acceptance -- Private Sanitary Seeger Extension Robert D. Isenhour Dear Mr, Hia Mail to. P.C7. f°h0x 4223 Concord,, NC 28026-04' I Phone:. 704.7 6.173:3 1. Fix: 04.79 5,1564 This is in response to the subject request for flow acceptance received 1l2 3/04, The Water and Sewer Authority of Cabarrus County (WSACC) has or currently expects to be able to make available capacity at the Rocky Ri',* er Wastewater Treatment Plant and appropriate sewer interceptors to transport and treat the domestic wastewater from the subject private residence. WSACC agrees to accept wastewater from the private residence based on information provided by King Engineering of Concord, Inc. (Civil Engineer for the project;) using North Carolina Department of Environrn.ent and Natural Resources (NCDENR) wastewater flow guidelines. The projected flow is 480 gpd; however .WSACC expects the actual wastewater flow to more closely approximate 330 gpd based upon Master Plan engineering data. By requesting flow acceptance, the City of Concord acknowledges that WSACC may need to upgrade, expand, or construct new facilities to accommodate the increased flow volume granted by this and previous flow acceptance. Appropriate design and construction will be initiated when actual flows dictate but rnay be subject to situations that WSACC does not expect or control. Based upon flow of 480 gpd and cost of $8.126/gpd to provide treatment and transportation capacity, this flow acceptance represents an. estimated capital expenditure in excess of $3,900. For your information and based upon NCDENR wastewater flow guidelines, WSACC has approved 11,650,145 gallons of flow .acceptance for the City of Concord from 1992 to present and 172,649 gallons of flow acceptance year-to-date including this request. Based upon the approved flow acceptances WSACC has committed capacity valued in excess of $94,669,078 for the City of Concord since 1992 including $1,402,945 for this calendar year. :Downstream. facilities from the proposed project are scheduled in WSACC's current Capital Improvement Program (CIP) to increase available capacity. Projects on the CIP are subject to approval by WSACC's Board of Directors, support from local governing bodies, regulatory approval, and funding availability. The following schedule of CIP projects is tentative and may be delayed by unforeseen circumstances: • Lower Coddle Creek Interceptor relief sewer. Scheduled completion date: 2009. +� Rocky River Wa.stewater Treatment Plant phase 11 upgrade. Scheduled completion date: 2004. Ity of Concord Robert D. Isenhour — Private Sewer January 30, 2004 Page 2 of 2 If construction of this project is not started within one year of the date of this approval, the approval is rescinded and a second request and approval will be required. Please notify NVSACC in waiting when construction of this project is initiated. If you have an questions, please call me at (704) 786-1783. cc: WSACC Engineering Staff Adam Dagenhart/Concord Sherri 'Moore/Concord Sam King P.E.,Xing Engineering Sincerely, John C. Murdock, III EXC'elltiVe Director ©2)17/€i4 Permit Number WQ0023548 Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer scnja.williams Permitted Fiow 480 Facili Track Permit Tracking Slip Status Protect Type In review New Project Version Permit Classification Individual Permit Contact Affiliation Facility Name 4 Inch Sanitary Sewer Service to Serve 2567 Saddlewood Circle Location Address Owner Owner Name Robert D. Isenhour, SFR Oates/Events Scheduled App Received Draft Initiated Issuance 02/03/04 Regulated Activities Private residence, single family Wastewater collection Outfatl NULL. Waterbody Name Mellor/Minor Minor Region Mooresvi County Cabarrus Facility Contact Affiliation Owner Type Non -Government e Owner Affiliation Robert Isenhour 206 Timberfieid Trail China Grove NC 28023 Publlc Notice issue Effective r i-4-/ 4 Requested/Received Events Additional information requested Additional informnation received Stream Index Number Current Claea n Subbasin 02/13/04 02/17/04 GINGER PS.ENHOUR DBA LEXINGTON PROPERTIES Michael F. Easley', Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan VV, IClirnek, P.E., Director Coleseen H. Sullins, Deputy Director Division of Water Quality TO: FROM: SUBJECT: February 17, 2004 MEMORANDUM Permit File WQ0023548 K. Marie Doklovic, PE Variance to Gravity Sewer MDC A 4" line extension is proposed for a single building lateral serving a single family residence at 2567 Saddl€:wood Circle (Robert & Ginger Isenhour) in the City of Concord, Cabarrus County. The lateral must traverse ad' ining property to connect to an existing sewer line owned by the City of Concord, SUMMARY - The line serves a single family residence. A variance to use a 4"line instead of a 6" fine is granted. No additional flow shall ever be connected to the line without first obtaining a permit from the Division. An easement agreement with location map shall be signed by each current property owner affected and be recorded in the Cabarrvs County Register of Deeds office no later than March 31, 2004. The easement agreement shall be attached to all property owners affected and run with the land. Failure to obtain andibr record the required easement by the timeframe above is a violation of this permit and may subject the Permittee to enforcement action or revocation of the permit. Non -Discharge Permitting Unit 1617 Service Center, Raleigh, NC 27699-1617 DENR Customer Service Center An Equal Opportunity Action Employer intemet http:rrh2o,enr.state_nc.usindpu Telephone (919) 733083 Fax (919) 715-6048 Telephone 1 800 623-7748 50% recycled/10% post -consumer paper King Engineering of Concord, Inc. Post Office Box 904, Concord, NC 28026 Phone: 704 - 786 - 5464, Fax: 704-788-6502 February 2, 2004 Ms. Sonya Williams State of North Carolina Department of Environment and Natural Resources Division of Water Quality Regional Office 919 N. Main Street Mooresville, North Carolina 28115 RE: 4" Sanitary Sewer Service to Serve 2567 Saddlewood Circle City of Concord, Cabarrus County, North Carolina FEB 0 3 2004 Enclosed, please find the following permit application package for the referenced project for your review and approval. If you have any questions, please contrqct our office at 704-786-5464. Sincerely, Sam King, Jr., PE/PLS King Engineering of Concord