Loading...
HomeMy WebLinkAboutWQ0022778_Regional Office Historical File Pre 2018Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Env ronrnent and Natural Resources Alan W. Klimek, RE., Director Division of Water Quality Coleen H. Sullins, P.E., Deputy Director Division of Water Quality July 02, 2003 Mr. Paul Campbell, Director of Engineering City of Concord P.O. Box 308 Concord, North Carolina 28026-0308 Subject: Permit No. WQ0022778 City of Concord Frye's Lake Sewer Extension-Peigler Ave Wastewater Collection System Extension Cabarrus County Dear Mr. Campbell: In accordance with your application received on June 11, 2003, we are forwarding herewith Permit No, WQ0022778, dated July 02, 2003, to the City of Concord for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1)15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 919 N. Main Street, Mooresville, NC 28115 DENR Customer Service Center Internet httio://h2o.enrstate nc,usit Telephone (704) 663-1699 Fax (704) 663-6040 Telephone 1 800 623-6748 ENR Mr. Paul Campbell Page In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Concord far the construction and operation of approximately 1,895 linear feet of 8-inch gravity sewer to serve a residential subdivision as part of the Frye's Lake Sewer fxtension- Peigler Avenue project, with no additional wastewater contribution into the Water & Sewer Authority of Cabarrus County's (WSACC) Rocky River WWTP (NPDES No. NC0036269) existing sewerage system (flow has already been allocated in Permit No. WQ0012378), pursuant to the application received June 11, 2003 and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast - Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit.. This permit shall become voidable unless the agreement between the City of Concord and WSACC for the collection and final treatment of wastewater is in full force and effect. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150E of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. Sincerely, for Alan W. Klimek, P.E. cc: Cabarrus County Health Department Mooresville Regional Office, Water Quality Section (WWTF Permit No. NC0036269) Wanda Fuller, Concord Engineering & Surveying, Inc. Water Quality Central Files NDPU Files NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of ssuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 21...0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed prior to January 1, 2004 and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (Le. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. Upon completion of construction and pr to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings," and one copy of the supporting design calculations to the Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities; 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500 11. Noncompliance Notificatio The Permittee shall report by telephone to the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Persons reporting such occurrences by telephone shall also file a written report in letter form within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Permit issued this the 2nd day of ,July, 2003. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Klimek, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0022778 Fast Track Engineering Certification Permit No, WQ0022778 July 02, 2003 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION E Partial El Final as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (ED periodically, El weekly, fl full time) the construction of the Frye's Lake Sewer Ext- Peigler Ave, Cabarrus County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE 919 N. MAIN STREET MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineers Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. 07/02103 er r 227"71 Program Category Non -discharge rge Pe it Tyr Gravity Sewer Extensiort, Pump Stations, Pressure Sewer Extensions Primary Reviewer dee.browder Permitted Flow 0 Facility Facility Name Frye"s Lake Sewer . t P eigier Ave Location Address Owner er Name City of Concord' Da to l veni iTracking l Status Project Type in review New Project Version Permit, Classificaon Individual' Permit Crtat AiPia' Ong `Issue App Received 06/11/03 Regulated Activities Subdivision Ou n it Region Mooresville County Cabarrus acPPit ^ Contect Affiliation Scheduled toted issuance Owner Type Government x Municipal Owner AM it Pail Campbell PO Box 308 Concord Punt ic Notice ue NC 8 Ettedtie n Requested/Received Events Additional information requested Additional information received Waterbody Name Stream Index lumber Current Class asin T-TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 • USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Application Number: (to be completed by DWQ) W61-002271 Owner: 41a. City of Concord Full Legal Name (company, municipality, HOA, utility, etc, • lb, Paul Campbell, City Engineer Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!) The legal entity who will own this system is: 0 Individual 0 Federal El Municipality 0 State/County 0 Private Partnership El Corporation Ej Other pecify): PO Box 308 1 e. Concord Street Address City • NC :1g, 28026-0308 State I Zip Code ° 1 h 704-920-5425 . , -Ii.. 704-766-4521 li, campbelp@ci.concord„nc,us el_ Telephone i Facsimile 1 E-mail 2. Project (Facility) Information: .--- - 2a• Frye's Lake Sewer Extensions - Peigler Ave, Collector 2b, Cabarrus Brief Project Name (permit will refer to this name) . County Where Project is Located Contact Person: 1; a, Paul Cam bell, City o Concord Name and Affiliation of Someone Who Can Answer Questions About this Application • 13c. campbelp@ci.concordmc.us (704) 920-5425 evei•.-1 Phone Number E-mail Project is E New 0 Modification (of an existing permit) If Modification, Permit No,: Owner is El Public (skip to item B(3)) 2a. If private, applicant will be: 0 Retaining Ownership (Le, store, church, single office, etc,) art 0 Leasing units (lots, townhomes, etc. - skip to Item B(3)) LIJ Selling units (lots, townhomes, etc, - go to Item F3(2b)) Ej Private (go to Item 2(a)) Water and Sewer Authority of Cabarrus County 2b, If sold, facilities owned by a (must choose one) 0 Public Utility (Instruction III) 0 Homeowner Assoc./Developer (Instruction IV) Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 4a. Rocky River WWTP Name of WWTF City of Concord i5b. 8-inch Owner of Downstream Sewer Receiving Sewer Size 4b. NC0036269 WWTF Permit No, WQ0012378 Permit Number ot Downstream Sewer (if known The origin of this wastewater is (check all that apply): El Residential Subdivision 0 Car Wash El Apartments/Condominiums 0 Institution Ej Mobile Horne Park 0 Hospital 0 School 0 Church 0 Restaurant 0 Nursing Home Ej Office 0 Other (specify): Volume of wastewater to be permitted in this project: 0 gallons per day 00 % Domestic/Commercial % Industrial % Other (specify): 8„ If the permitted flow is zero, indicate why: Ej Interceptor Line - Flow will be permitted is subsequent permits that connect to this line El Flow has already been allocated in Permit No. W00012374 • Rehabilitation or replacement of existing sewer with no new flow expected .1-17TA 02/03 ST-TRACK APPLICT1ON for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item 8(7) or the design flow for line or pump station sizing if zero flow in the space below, Values other than that in 15A NCAC 2H .0219(1)(1-2) must be approved odor to submittal of this application. Submit a separate request to the Division of Water Quality, Non-sischarge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H .0219(1)(3), See permit W00012378, which accounted for this flow 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) 8 Length (feet) Gravity or Force ain (pull down menu) 1,895 Gravity Gravity Gravity Gravity Gravity Gravity Gravity ENTER TOTAL LINE LENGTH IN MILES 0.36 . Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Power Reliability Option Location ID Design Flow Operational Point (dual line feed, permanent generator w/ATS, (as shown on plans) (MGD GPM @ TDH portable generator w/telemetry, wet well storage) 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? El Yes 1:-.1 No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested: SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERT1NENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have the folio ng per certifications been submitted for approval. Wetland/Stream Crossings - General Permit or 401 Certification? 11:1 Yes Z No Z N/A Sedimentation and Erosion Control Plan? El Yes El No Z N/A Stormwater? D Yes No 4 N/A FTA 02/03 —ST-TRACK APPLICATJON for GRAVITY SEWERS, PUMP STATIONS. AND FORCE MANS PAGE 5 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/0 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary) This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: 1:1 A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody: AND, _ 0 1 Ej A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability LL option for any pump station near a Class C down slope waterbody. Location ID Name of Waterbody Stream Waterbody on Map Waterbody County -- River Basin Index Classification Irish Buffalo Creek Cabarrus Yadkin L 13-17-9-(2) G Submit the 8.5" x 11" topographic map as required in Instruction VI regardless of whether a classification is provided] Applicant's Certification: 1, SIGNING OFFICIAL NAME, attest that this application for PROJECT NAME has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 743-215.6A and 143-275.68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation, Signi g Official Signature 2 Professional Engineer's Certification: Date I attest that this application for City of Concord has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 7, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215,6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10.000 as well as civil penalties up to $25,000 per violation, 2a. Brent eus Professional Engineer Name 2b, Black & Veatch Engineering Firm 2c, 8520 Cliff Cameron Drive, Suite 350 Address 2d, Charlotte City 2g. 704-548-8461 2h, 704-548-5640 Telephone Facsimile 2e, NC 2f, 28269 State Zip eussbni bv.com E-mail 1-14tft,0 CARO Seal, Sgnature & Date FTA 02/03 . y OF CONCORD VanIC.ruavinPlArJR ("RIMI VOW Ar1Eff COI [JAYS ltn. (A% FOUR 1 UNDRE DOLLARS & ZERO CENT S NC DEPT OF ENVIRONMENT &NATU AL (ES 1617 MAIL SE 'VICE CENTER E ALE1UH, NC "7699-1617 v1/410 002:2- `1 000 2 5 29 ?B» ':0 5 3 L09013',i. 200 5 0006 L SfI' 252918 252978 ©4/04/03 Y 4 0 0 0 0 I,�rira v.I ��.w i^+�wtirrEtf 6M1l,,Ite7I I `=1�i City of Concord Engineering Department Scott Padgett, Mayor W. Brian Hiatt, City Manager Paul D. Campbell, P.E., Director of Engineering June 6, 2003 N.C.. Department of Environment and Natural Resources Division of Water Quality Non -Discharge Permitting Unit 919 N. Main St, Mooresville, North Carolina 28115 SUBJECT SANITARY SEWER EXTENSIONS PEIGLER ROAD SEWER EXTENSION City of Concord Cabarrus County Dear Sir or Madam: a city meeting thefuture.,. NC DEPT. OF ENV4RONMENT AND NATURAL RESJRCES MOORESVILLE PZ•Gt)KAL OFFICE .7e".• alm r JUN 1 1 2003 WATER MA We are enclosing for your review and approval, one original and one copy of the executed Non - Discharge Permit Application form, a check in the amount of $ 400.00, a letter of flow acceptance from the WWTF and the Delegated Municipality Certification form for the installation of 1,895 +/- linear feet of 8-inch gravity sanitary sewer to serve the above mentioned project in the northwest section of Cabarrus County off of Pitts School Road. This application is in accordance with your Gravity Sewer Minimum Design Criteria. Upon completion of the project, you shall receive a copy of the Engineer's Certification and a copy of the Record Drawings. Your cooperation in this matter is greatly appreciated, Ifthere are any questions concerning this application or plans, please call us at (704) 920-5425. Sincerely, CITY OF CONC Paul D. Campbell, P.E. Director of Engineering PDC/svm Enclosures cc: Project No.: 2003-014 File No. 2 (DWQ) 850 Warren C. Coleman Blvd, Post Office Box 308 Telephone: (704) 920-5425 Concord, North Carolina 28026-0308 Fax: (704) 766-4521 State of North Carolina Department of Environment, Health, and Natural Resources Division of Environmental Management 512 North Salisbury Street • Raleigh, North Carolina 27626.0535 Governor Georg: T. EN^ y, 3r., Sectary Memorandum To: Delegated Municipali From: Steve W. Tedder, Chic Watt Quality Section SubjectDelegated Municipalities Checklist for Revised Non -Discharge Permit Applications The Division of Environmental Management's Water Quality Section has revised the Gravity Sewer Non -Discharge Permit Application Form. The form now incorporates the basic information that the Division feels is necessary in order for the delegated municipalities to perform a review on a gravity sewer project for the Division; therefore, the Division will no longer require that the "Delegated Municipalities Gravity Sewer Design Checklist" be completed and submitted. We do, however, require that the delegated municipality perform the same type of review as always required and complete the bottom portion of this page and attach it as the last page of all gravity sewer applications that 7-.. e being submitted as a delegated municipalities project. If you have any questions on this matter, please contact Mr. Randy Jones at 919/733-5083. DELEGATED MUNICIPALITY GRAVITY SEWER CERTIFICATION (THIS FORM MAYBE PHOTOCOPIED FOR USE AS AN ORIGINAL) Applicant.. c ,� co Project Name: May 1,. at, PhD. Dir^cior Delegated Municipality Reviewer's Certification: 1, Paul D. bell , attest that the subject plans and specifications have been reviewed under my supervision and that those plans and spccificati0P.5 are consistent with the information that has been specified on the Non -Discharge Application and the Division of Environrnenta? Management's minimum design requirements for gravity sewer projects.. Delegated Municipality ReVicwer°s NC Professional Engineer's Reg station No.: Sesl and Signature (specify date): FORM: PAGE 1 1GS 4191 8906