Loading...
HomeMy WebLinkAboutNC0024295_Fact Sheet_20210424DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 NC DEQ/DWR/NPDES FACT SHEET FOR NPDES PERMIT RENEWAL NPDES PERMIT NC0024295 Facility Information Applicant: Carolina Water Service Inc. of NC Facility Name: Connestee Falls WWTP No. 1 Applicant Address: P.O. Box 240908, Charlotte, NC 28224 Facility Address: 183 Connestee Utility Dr., Brevard, NC 28712 Facility Contact Infer 704-319-0523; Tony Konsul, Operations Officer [Tony.Konsul@carolinawaterservicenc.com] Permitted Flow 0.360 MGD / 0.460 MGD Type of Waste: 100% domestic wastewater Facility/Permit Status: Class II (Phased- 0.30 MGD, 0.46 MGD) Renewal / expansion County: Transylvania Miscellaneous Receiving Stream: French Broad River Regional Office: Asheville Stream Classification: B; Tr 8-Digit HUC: 06010105 303(d) Listed? No Permit Writer: Joe Corporon Subbasin: 04-03-01 Date: 17Feb2021 Stream Index: 6-(1) Drainage Area (mi2): 140 4441111PF Lat. 35° 11' 16" N Long. 82° 43' 50" W Summer 7Q10 (cfs) 99 Winter 7Q10 (cfs): 124 Average Flow (cfs): 451 IWC (%): 0.5 (at 0.360 MGD) 0.7 (at 0.460 MGD) RENEWAL OVERVIEW: • Connestee Falls WWTP is a minor, 100% domestic WWTP serving approximately 1,033 homes, or an estimated 2,583 persons of the Connestee Falls residential development in Transylvania County. • This renewal documents a Change of Ownership from Transylvania Utilities to Carolina Water Service Inc. of Carolina. The current permit expired on 30Sep2020. The new Peiriuttee submitted a renewal application (Form D) dated 30Jan2020, received by the Division on 03Feb2020. • The renewal application informed DWR that the Permittee completed a partial flow expansion achieved in accord with Authorization to Construct No. 024295A02 (05Dec2017). The facility's new treatment works has a design flow 0.360 MGD. • It follows therefore, that this permit continues to authorize a potential future expansion to 0.460 MGD as previously permitted, i.e., this remains a phased -flow permit. Carolina Water Service, Inc. of North Carolina -- Fact Sheet NPDES Renewal, 2021 Page 1 of 3 DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 RECEIVING S IREAM: • The facility discharges treated wastewater via Outfall 001 to the French Broad River in the French Broad River Basin (subbasin 04-03-01, HUC 06010105). • The receiving stream is classified B-Tr waters [stream segment 6-(1)]; it is not listed on the 2018 final 303(d) list. FACILITY PERFORMANCE/COMPLIANCE REVIEW: DMR Data have been reviewed for the period of Jan2018 through Jan2021. Table 1. Lists average and maximum effluent data collected from 1/2012 through 9/2015. Parameter Flow BOD5 Total Residual Chlorine Ammonia Nitrogen Total Suspended Solids Fecal Coliform (MGD) (mg/L) (ug/L) (mg/L) (mg/L) #/100m1 average 0.235 3.60 10.33 1.74 5.39 4.37 maximum 0.492 19.3 34 14.8 32.2 61 Limit(MA) 0.3 30 28 (DM) 30 200 Parameter TotalNitrogen Total Phosphorus (mg/L) (mg/L) average 2.86 1.4 maximum 4.12 2 Limit DM: Daily Maximum; MA: Monthly Average MONTH YEAR PARAMETER VIOLATIONDATE VIOLATION COMMENT 12 2020 Coliform, Fecal MF, MFC 12/26/2020 Broth, 44.5 C 1 2019 Chlorine, Total Residual 01/22/2019 Below DWQ Compliance Level 3 2019 Chlorine, Total Residual 03/05/2019 Below DWQ Compliance Level 6 2019 Chlorine, Total Residual 06/24/2019 Below DWQ Compliance Level 7 2019 Chlorine, Total Residual 07/22/2019 Below DWQ Compliance Level 7 2019 Chlorine, Total Residual 07/09/2019 Below DWQ Compliance Level 7 2019 Chlorine, Total Residual 07/08/2019 Below DWQ Compliance Level 8 2019 Chlorine, Total Residual 08/05/2019 Below DWQ Compliance Level 9 2019 Coliform, Fecal MF, MFC 09/28/2019 Construction activities to switch Broth, 44.5 C over to new facility. 9 2019 Coliform, Fecal MF, MFC 09/21/2019 Construction activities to switch Broth, 44.5 C over to new facility. 3 2017 Coliform, Fecal MF, MFC 03/21/2017 Broth, 44.5 C Coliform, Fecal MF, MFC 03/14/2017 3 2017 Broth, 44.5 C • Permit Violations. Tim Heim of ARO inspected the facility on 21Jan2021. At the time of inspection, no violations of permit conditions were observed, noting further that this is a relatively new state of the art facility. Carolina Water Service, Inc. of North Carolina -- Fact Sheet NPDES Renewal, 2021 Page 2 of 3 DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 PERMIT LIMIT DEVELOPMENT (New Conditions for 0.360 MGD and Phased II expansion to 0.460 MGD): • Limits and monitoring conditions remain the same for renewal. The expansion from 0.300 the 0.360 MGD has not affected limits and monitoring conditions. Likewise, potential expansion to 0.460 MGD flow (renewal Phase II) remains the same as the previous permit [see permit sections A, (1.) and A. (2.)]. • For previous limit and monitoring requirements development and review of the Engineers Alternatives Analyses (EAA), see previous Fact Sheet (2017). SUMMARY OF PROPOSED CHANGES: The following permit changes are proposed for this permit renewal: 1. Revised permit Sections A, (1.) and A. (2.) to reflect flows of 0.360 and 0.460 MGD 2. Updated treatment -works components (see Supplement to Permit Cover Sheet) 3. Updated permit text in accord with current permitting guidance. PROPOSED SCHEDULE FOR PERMIT ISSUANCE : Draft Permit to Public Notice [tentative]: Permit Scheduled to Issue [tentative]: 23Feb202 1 02Apr202 1 NPDES Contact: If you have any questions on any of the above information or on the attached permit, please contact Joe R. Corporon [joe.corporon@ncdenr.gov] Signature Date 17Feb2021 Carolina Water Service, Inc. of North Carolina -- Fact Sheet NPDES Renewal, 2021 Page 3 of 3 DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 CONNESTEE FALLS WASTEWATER TREATMENT PLANT #1 PLANT REPLACEMENT OWNER CIVIL ENGINEER SURVEYOR ELECTRICAL ENGINEER STRUCTURAL ENGINEER Carolina Water Service Inc. 4944 Parkway PIa7a Blvd, Suite 375 Charlotte, NC 28217 704.525.7990 Martin Scanlon Land Design, Inc. 223 North Graham St. Charlotte, NC 28202 704.333.0325 LDSI Inc. 508 West 5th St. Suite 125 Charlotte, NC 28202 704.337.8329 Labella Associates, PC 1520 South Blvd., Suite 210 Charlotte, NC 28203 jim Henderson, PE jenderson a©label lapc.com 704.366.1776 Barry O. Lambert, P.E., LEED AP PO Box 667446 Charlotte, NC 28266 704.621.3080 5999 GREENVILLE HIGHWAY TRANSYLVANIA COUNTY, NC NPDES # NC0024295 SHEET INDEX: C6.12 DETAILS - CLOTH MEDIA FILTER C I.0 COVER CHAPTER 7 CHAPTER I C7.0 FORCE MAIN - OVERALL C 1.1 EXISTING CONDITIONS C7. 1 FORCE MAIN PLAN & PROFILE C I.2 EXISTING CONDITIONS -DETAIL C7.2 FORCE MAIN PLAN & PROFILE C 1.3 DEMOLITION PLAN - PHASE I C7.3 C I.4 DEMOLITION PLAN - PHASE 2 CHAPTER 8 CHAPTER 2 - RESERVED FOR PLANTING PLAN -- RESERVED FOR EROSION CONTROL PLANS CHAPTER 9 CHAPTER 3 C9.0 TREATMENT PLANT - PLAN C3.0 SITE LAYOUT OVERALL C9. I TREATMENT PLANT - SECTION C3. I SITE LAYOUT C9,2 C3.2 CONSTRUCTION SEQUENCE CHAPTER 10 C3.3 HYDRAULIC PROFILE C 10.0 INFLUENT SCREEN PLAN C3.4 DETAILS - BUILDING C 10. I DETAILS - INFLUENT SCREEN C3.5 DETAILS -SITE CHAPTER I I C3.6 DETAILS -SITE CHAPTER 4 CHAPTER 12 C4.0 GRADING PLAN -- RESERVED FOR STRUC: I URAL CHAPTER 5 CHAPTER I3 -- RESERVED FOR STORM DRAINAGE PLANS - RESERVED FOR BUILDING PLANS CHAPTER 6 C6.0 UTILITY LAYOUT C6.1 UTILITY PROFILES C6.2 PIPING PLAN - BLOWER BUILDING C6.3 PIPING PLAN - FILTER BUILDING C6.4 AIR PIPING PLAN - OVERALL C6.5 AIR PIPING PLAN - SEC -IONS C6.6 UTILITY - BUILDING FLOOR SLAB PENETRATIONS C6.7 UTILITY DETAILS - WATER AND SEWER C6.8 UTILITY DETAILS - WATER AND SEWER C6.9 DETAILS -PLANT EQUIPMENT & PIPING C6.10 DETAILS -PLANT EQUIPMENT & PIPING C6. I I DETAILS -WEIR BOX Location Map (1" = 3,000') ‘‘ °Vill...1..7. .. ikil,/ , CORPORATE SEAL 0'• .. ••o,N,ti CAg 11 111111tt% f�,ttttt►,o 9/19/2017 FINAL DRAWING - FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION W O U REVISIONS: Plans DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 \\\ 01111 ;1111111 II flit di ') (APPROXIMATE ALIGNMENT) / EX. WORKSHOP I OR UP 110;111111/1 1111;1111i //// iji OF ANY CONSTRUCTION ACTIVITIES II x r-15/ CONTRACTOR TO VERIFY LOCATION NN 7/ / \.N 111/1/1111/Inif(u//)//i I 'hi, lb. (if, /hi/ j/V/ / EX. CHLORINE FEED BUILDING !II 'ill I/ I' Ili I I/ III 17/(7//11 ///// )//ii 1 11111/1111/111111/11/1/11/1/1/11/11117*////////////// i \\\ II ft III I 11\11, bil ;// /2/ )//// %/// ///67 /7/ //2//'', ;5= ALIGNMENT NOT FIELD LOCATED `-•.-1) ,/,/a10/c/ L \4 01 +--"; \ »))))\`)1)0;1111\\)KV -\\\N \\ IP I I 01 7/ion/ill/dog //y)) - N 1/1/1i N EX. CMP (TYP) VARIABLE SIZE AND SLOPE TO BE REMOVED INV OUT: 2618.98 \ -IL= NNN \ \ rr( / N\ EX. CL CONTACT TANK INV: 2616.16 \NN NNNN \\ \\\\ \\ \\\ \\\ \\‘ EX. CHEMICAL FEED BUILDIN TO BE REMOVED \, RIM:2624.80 EX. FLOW DISTRIBUTION \\:\ \‘: \\\\ \\\\ \\.\\\ \\\ \\ \\ N EX. CL CONTACT TANK \\\\\ \\\\\ \\\\ \\\\ \\ \\\ \\\\ \\\ \\vs\\\\\ \ \\\ \\\ \\\\\\\ EX. SSMH-4 TO \BE REMOVE\ 131'°\**\\ \\\\,:\\\\\\ \\\\)II \ci\\\\\\ \\\ INV IN:2621.83 8"PVC \\\ III' II I/// \\\ 11\ EX- GRAVEL CrYP) ss IIij )1 nil I/ AND DEPTH PRIOR TO THE START /// EX. SSMH-3 TO BE REMOVED EX-. STORAGE BUILDING TO BE REMOVED V / • /I /1\? Ili II/ 02' //if EX. SSMH-2 (TO REMAIN) EX. CLARIFIERS • )71; 1`, ,1114 /////-///// w 1:NAoii:6:0F94 // \ \ \<\ ///// // //i/ / \ \ i ////,' / / / \ i \ /4// (/ Z\ -:-. -7:7.-4, TO BE REMOVED 1 \<\ A • EX. AEROBIC DIGESTER \ TO BE REMOVED '<Ft. • ss 0 \*-, <„ 0, v, \ 3 0111 11(/ • rfr \ \ \ \ \ \ , \---., -...., "---T ''''' ':N.--- 'Ns- ------ N • \ LIMITS OF sSURVEY(TYP) ---- N/F DB/PG 477/730 WOOD FENCE creP) TO BE RELOCATED •• EX. 'GRIT CHAMBER • TO BE REMOVED • • INV: 2628.00 // (;) /43 ti zy/ difrfr- ss // //0/// • • s'' • N ii•s% ',`.,,, \ ----___ EX. SSMH-1 (TO REMAIN) INV IN:2605.03 INV OUT:2604.87 • \ \ \\'' z 7 ///lite \ \—/./ ////1/04-_ //1/i/g/ // -7/2 ////' EX. CHAIN LINK FENCE (TYP) /01 PORTIONS TO BE REMOVED /if/ ,--7,7;; -7.= 8•70 AI I I • • N ucp • INV: 2601.40 • • LEGEND and NOMENCLATURE SYMBOLS • • • o()g0ononn Ex. iron pipe/rod or nail Ex. concrete monument New iron pipe Calculated point Cable pedestal Telephone pedestal Electric pedestal Fiber-optic marker Traffic signal box Water meter Fire hydrant Valve (water or gas) Sanitary sewer manhole Sanitary sewer cleanout Storm curb inlet Drainage inlet (w/ grate) Storm drain manhole Utility pole Lamp post Signal pole Guy wire Sign post LINETYPES OU - SD Fence Overhead utility Water Sanitary sewer Storm drain Ex. Major Contour Ex. Minor Contour ABBREVIATIONS DB PB or BM N/F Pg. SF Ac. RNV NCSR NCDOT RNV Ex. RCP PVC (M) (P) (D) Deed Book Plat Book / Book of Maps Now or formerly Page Square feet Acres Right-of-way North Carolina State Route NC Dept. of Transportation Right-of-way Existing Reinforced concrete pipe Polyvinyl chloride pipe Measured Platted Deed ADDITIONAL NOTES: LOCATION MAP (NTS) EXISTING CONDITIONS PLAN AS SHOWN IS A COMPOSITE OF SURVEY, GIS, AND AS-BU1LT INFORMATION. EXISTING CONDITIONS PLAN FOR REFERENCE ONLY. CONTRACTOR TO FIELD VERIFY ALL INVERTS AND UTILITIES. CONTRACTOR TO NOTIFY ENGINEER AND OWNER OF ANY DISCREPANCIES. SURVEY PREPARED BY: LDSI, INC. DATED: AUGUST 13, 2016 co cc, 01 E co 13) iZ Lir CORPORATE SEAL ti too 9/19/2017 FINAL DRAWING - FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION 0 CL CAROLINA WATER SERVICE, INC OF NC EXISTING CONDITIONS -DETAIL U 10' 0' 10' 20' 40' DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 r-" --- _ __--.....„--,,_- „..,-- -.>-- 7 / -7-------T----,----- ----=----_,-----, /74 /// /; - !.r...//, im'/`�• .--., --- 7:; : '-- • :- -- z.--- - -- _. _ ._ •••- : --- 5 *" . . "'''' - • - - - - - - -- - - --_ _ _ ____- - - -: --- --- - --. -:- -V.: - - - r z//4 1 r .- -r,> REMOVE EX. CMP SOUTH OF THIS POINT / / j/ , ��i " ,, CMP NORTH OF THIS POINT TO BE CAPPED /�/ •'! a - - ' .� WITH CONCRETE A • ND REMAIN IN PLACE , - - - - - - - - N' N\ NN \ \\ \ \ \- - - --;' ( - ---e.,_ , , , ,, , ,----: e_,•.'' : • •••'. . ../Y / r - ^� N\ \ \\ii, 1 \\\i �, EX. CL CONTACT TANK \\\1\, TO BE REMOVED ",\\ \ \ (PHASE 2) Z --N\� \\ , \\\\\ \\\. \ \ , .\e t \\ \( \\,i \ \ „ ,\ \ \ EX. CHEMICAL FEED BUILDING \\\ \\\\ ,, \ , \ , TO BE RPHAS E ) \ :,\\\\\\\\\\ `�\\\\\�\\\\\\\�\ \li\\�\\1 r\` \\ 1 �� EX. CLCONTACT TNK\ \ ` TOBEMOD \\\\ \\ ,` ` \`, �� \1 5 (PHASE 2) i :\\ i 1 1 \\\\ \\ \ \ \\\\\\\\\ V \\\*\ \\\\\\\ )1'81111 11 if i/ I I; I ')\ \ \\1\1\\i'. \\\ \ \ \\Vt\\\\\\\\ W111111111' 111//1/1//i I))1 11 \\‘‘\\\\A}1.1111111111 111 I I 1 1 I/ -I i I 1 1 ' 1 I EX. EFFLUENT PIPE TO OUTFALL / k t i ° (APPROXIMATE ALIGNMENT) / i) 1:1liiiii(f i • CONTRACTOR TO VERIFY LOCATION 1 11 1) J i j j ) i , AND DEPTH PRIOR TO THE START x f J OF ANY CONSTRUCTION ACTIVITIES J I/ II11111{11111�j/liIl{1/ /�) 1 { 1 II I( // )/) { I 11 f € EX. CiHL1 !) . FEit ED B1 1 / { i f / / 11 1 { f { / �/ 1 1 l TO REMAIN UNTIL PROPOSEiG D 1 1f 1 i 1 ! 1 11 11 (/ / / /// J TREATMENT PLANT HAS BEEN 11 11 11 J f �� // / l% PLACED IN SERVICE 1{1 II {1 11, 11 (f ///f%'//'1/r'1/71 1 {1 11 {1 { i1,11 1,11 {7/// /////// { . , 1, f{ /11 ,1jf"lJi {11{1/ { ,11,I1f{7// //r /////// 0/,'// ,i) //////))//1//iP/P/2 ' //// ///�//////�A//// f / /// 1 1 f'/ � / / / f /// / /I/ // II/ /� // / / EX. AEROBIC DIGESTER /// �� //,'//�'�,///;' I ( TO BE RPF AAOS ED // / / /t/ / ////////,,//,, / 1 ///////p7 c/ 7 X 1 _ \ 1 i ////dP / \ /1 I ///%%;' //,/�j/ "i� EX. 15"CMP (TYP) /� / ALIGNMENT NOT FIELD LOCATED / , // f / / / / ENV; 2588.13 t� �- �// / / 11 /�7��1 /Ye/\\V \Al\i\ 0\\1\\ \\ 1' \` \`\ `` `EX. CHAIN LINK ENCE (TYP)N \ \ N --_---,,--,,,--,-,/ 1/ /� /�/'/ // / / �▪ �� 1 t �� �� N✓ PORTIONS TO BE REMOVED \ / �/� /// /� ) � }\\1 ��\��\ AND/OR RELOCATED \ i)1)1011/11 /11 01111 \ jY4 jiii/j11/ Id/ /7 \N\ N N ` \ \ N \N \ � \\ \ ; \ \ N \\ N\ \ NN \ \\\ \ \ \ \ N\ EX. GRAVEL (TYP) \ \\\ \ \\ N N N ` r•- \\`N e✓SROGT N�\ _ `- �� EX. SSMH-2 (TO REMAIN) TO BE REMOVED •x , ,:N, NN, --- ------ :- .._ -,. -__ -___ N NN N EX. CMP (TYP) \\ VARIABLE SIZE AND SLOPE TO BE REMOVED (PHASE 1) EX. SSMH-1 • r4f LIMITS OF 'SURVEY(TYP) CONSTRUCTION. CONTRACTOR SHALL ADJUST FENCE N THE PROJECT SHALL REMAIN IN PLACE DURING SECURITY FENCE NOTE: EXISTING SECURITY FENCE AROUND THE PERIMETER OF • LOCATION AND ADD ADDITIONAL FENCING/GATES, AS NEEDED, AS CONSTRUCTION PROGRESSES. SECURITY \ \\\ \ \ \ \ \\\ \ \\: \ \\\ \\\\\\\\ \ \ \ \ \ \N\ \--- "•-•.\\ (''P - \ \ \ \ \ \ N \ "-- \ _, \\\\ \ \\\ \\\\\ \\\\ \ NN INV IN: 2625.81 7- \---- ---- \ N N \ --. -.,. --_ \ EX. WORKSHOP TO BE REMOVED (PHASE 2) EX. SSMH-3 TO BE REMOVED (PHASE 2) EX. AERATION BASINS TO BE REMOVED (PHASE 2) 15: tt.,,,,,,.,,,•4•Tio.1:••,•• V!2 6 \ 7 \7 EX. LIGHT POLE (TYP) \ TO BE RELOCATED (PHASE 1) LIMITS OF SURVEY(TYP) EX. FLOW DISTRIBUTION TO BE REMOVED 1NOTE: GRIT CHAMBER MAY BE REMOVED DURING ------ - -........ \ PHASE 1 WITH COORDINATION FROM THE OMER -....„.... - „, \ AND ON SITE OPERATOR. TEMPORARY PIPING TO BE \ \ INSTALLED PRIOR TO DEMOLITION SEE SHEET C6.10 „...,.. TO BE REMOVED N • • y. TO BE REMOVED FROM VALVE TO GRIT CHAMBER / ,INOTE: STORAGE BUILDING TO BE REMOVED ONLY AFTER BUILDING #1 HAS BEN COMPLETED EX. STORAGE BUILDING TO BE REMOVED / 2/ \\\\\ /////// ,6\.\\\\\\\\ %.2-7/'/// \\ \ \\'\:// zzz7/41141/Dir " /A \ / \ 41/0, \ //Ai' 1/I( \c ) \'11 L-?/ /:// \I i)\1\1\\\\\\\\\\\\\\1\-FIL'''u//////z/77-7-'/7/7//2///;:7/82s-1_. //1", D/OR RELOCATED EX. CHAIN I:INK FENCE (TYP) EX. GRIT CHAMBER III //(// // c's ocp N INV: 2601.40 04, \\NL\ \\\:\\ p j. ctcp LEGEND and NOMENCLATURE SYMBOLS • • • El 71) Ex. iron pipe/rod or nail Ex. concrete monument New iron pipe Calculated point Cable pedestal Telephone pedestal Electric pedestal Fiber-optic marker Traffic signal box Water meter Fire hydrant Valve (water or gas) Sanitary sewer manhole Sanitary sewer cleanout Storm curb inlet Drainage inlet (w/ grate) Storm drain manhole Utility pole Lamp post Signal pole Guy wire Sign post LINETYPES OU SS SD Fence Overhead utility Water Sanitary sewer Storm drain Ex. Major Contour Ex. Minor Contour ABBREVIATIONS DB PB or BM Pg. SF Ac. RNV NCSR NCDOT RNV Ex. RCP PVC (M) (P) (D) Deed Book Plat Book / Book of Maps Now or formerly Page Square feet Acres Right-of-way North Carolina State Route NC Dept. of Transportation Right-of-way Existing Reinforced concrete pipe Polyvinyl chloride pipe Measured Platted Deed LOCATION MAP (NTS) DEMOLITION NOTES: 1. EXISTING TREATMENT PLANT TO REMAIN IN OPERATION AT ALL TIMES. REFER TO CONSTRUCTION SEQUENCE FOR ADDITIONAL PHASING INFORMATION. CONTRACTOR TO COORDINATE ALL ACTIVITIES WITH TREATMENT PLANT OWNER AND ON -SITE OPERATORS 2. CONTRACTOR SHALL SUBMIT DEMOLITION SCHEDULE AND RECYCLING PLAN TO OWNER PRIOR TO PROCEEDING WITH DEMOLITION ACTIVITIES. 3. EXTENT OF SITE CLEARING IS SHOWN ON EROSION CONTROL PLANS. 4. CONDUCT SITE DEMOLITION OPERATIONS TO ENSURE MINIMUM INTERFERENCE ADJACENT OCCUPIED OR USED FACILITIES. DO NOT CLOSE OR OBSTRUCT DRIVEWAY, WALKS OR OTHER OCCUPIED OR USED FACILITIES WITHOUT PERMISSION FROM THE OWNER. 5. ALL PROPERTY AFFECTED BY THIS WORK SHALL BE RESTORED TO A CONDITION EQUAL TO OR BETTER THAN THE EXISTING UNLESS OTHERWISE SPECIFICALLY EXEMPTED BY THESE PLANS. 6. REMOVE WASTE MATERIALS AND UNSUITABLE AND EXCESS TOPSOIL FROM PROPERTY AND DISPOSE OF OFF -SITE IN A LEGAL MANNER. (PERMIT REQUIRED FOR OFF -SITE DISPOSAL) 7. LOCATE EXISTING ABOVE GROUND AND UNDERGROUND UTILITIES IN AREAS OF WORK. IF UTILITIES ARE TO REMAIN IN PLACE, PROVIDE ADEQUATE MEANS OF SUPPORT AND PROTECTION DURING DEMOLITION OPERATION. 8. SHOULD UNCHARTED, OR INCORRECTLY CHARTED PIPING OR OTHER UTILITIES BE ENCOUNTERED DURING DEMOLITION, CONSULT PROJECT ENGINEER AND UTILITY OWNER FOR IMMEDIATE ACTION. 9. DEMOLISH AND COMPLETELY REMOVE FROM SITE MATERIAL INDICATED ON PLAN OR NOTED 'TO BE REMOVED". ALL MATERIAL SHALL BE SEPARATED AND RECYCLED TO THE GREATEST EXTENT POSSIBLE. CONTRACTOR SHALL KEEP AN ACCURATE DISPOSAL AND RECYCLING RECORD INCLUDING WEIGHTS AND VOLUMES OF ALL DEMOLISHED MATERIAL. 10. CONTRACTOR TO PROVIDE THE OWNER WITH A RECYCLING PLAN PRIOR TO THE START OF CONSTRUCTION. 11. PROTECT STRUCTURES, UTILITIES, SIDEWALKS, PAVEMENTS, AND OTHER FACILITIES FROM DAMAGE CAUSED BY SETTLEMENT, LATERAL MOVEMENT, UNDERMINING, WASHOUT AND OTHER HAZARDS CREATED BY THE DEMOLITION OPERATION. 12. CONTRACTOR SHALL RESTORE ALL DISTURBED AREAS TO EXISTING CONDITIONS OR BETTER. 13. CONTRACTOR SHALL MAINTAIN POSITIVE STORM DRAINAGE DURING CONSTRUCTION TO INSURE NO DAMAGE TO ADJACENT PROPERTIES OCCURS DURING STORM EVENTS. 14. CONTRACTOR TO REMOVE ALL VISIBLE OR REASONABLY IDENTIFIABLE MATERIAL, EQUIPMENT, ETC. FROM THE SITE IF NOT NEEDED FOR NEW CONSTRUCTION. 15. THE CONTRACTOR IS CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS ARE BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES, PREVIOUS DESIGN DOCUMENTS, AND WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE LOCATION OF EXISTING UTILITIES MUST BE VERIFIED IN THE FIELD BY THE CONTRACTOR PRIOR TO CONSTRUCTION. 16. ALL DEMOLITION AND CONSTRUCTION SHALL COMPLY WITH APPLICABLE BUILDING CODES AND LOCAL RESTRICTIONS. THE CONTRACTOR MUST COMPLY WITH ALL OF THE CONTRACTOR REGISTRATION REQUIREMENTS OF ALL GOVERNING AUTHORITIES. 17. PRIOR TO THE COMMENCEMENT OF DEMOLITION, THE CONTRACTOR SHALL COORDINATE HIS ACTIVITIES WITH ALL UTILITY COMPANIES SERVING THIS AREA. THE CONTRACTOR IS TO COORDINATE FULLY WITH THE UTILITY COMPANIES ON THE EXACT LOCATION OF ALL UNDERGROUND UTILITIES PRIOR TO DEMOLITION, CONSTRUCTION, AND EXCAVATION. 18. MINIMUM DEPTH FOR REMOVAL OF ALL OBJECTS SHALL BE THREE (3) FEET BELOW GRADE. THE CONTRACTOR IS RESPONSIBLE FOR PROPER RECYCLING AND/OR DISPOSAL OF ALL WASTE MATERIAL. 19. ALL PAVING REMOVAL AND DEMOLITION SHALL BE PERFORMED AS SHOWN ON THE PLANS OR AS DIRECTED BY THE ENGINEER OR OWNER. 20. RELOCATION OR REMOVAL OF OVERHEAD OR UNDERGROUND UTILITIES SHALL BE COORDINATED WITH THE APPROPRIATE UTILITY COMPANY. RELOCATION OR REMOVAL OF EXISTING UTILITIES SHALL BE DONE BY OTHERS AND PAID FOR BY CONTRACTOR UNLESS PREVIOUS NEGOTIATIONS HAVE BEEN MADE WITH OWNER. 21. CONTRACTOR SHALL REMOVE THE EXISTING LIGHT POLE IN THE DEMOLITION AREA AT THE OWNERS DIRECTION. 22. ALL PROPOSED PAVEMENT CUTS SHALL BE SAW CUT ONLY. 23. CONTRACTOR SHALL PROVIDE A MINIMUM OF 72 HOURS ADVANCE NOTICE TO THE OWNER PRIOR TO STARTING DEMOLITION ACTIVITIES. 24. CONTRACTOR SHALL VERIFY AND PROTECT ALL PUBLIC AND PRIVATE UTILITIES. ANY WORK ASSOCIATED WITH SAID UTILITIES TO BE COORDINATED WITH APPROPRIATE UTILITY COMPANY 25. THE CONTRACTOR SHALL IMMEDIATELY REPORT TO THE OWNER AND ENGINEER ANY DISCREPANCIES FOUND BETWEEN ACTUAL FIELD CONDITIONS AND CONSTRUCTION DOCUMENTS AND SHALL WAIT FOR INSTRUCTIONS PRIOR TO PROCEEDING. 26. PRIOR TO BEGINNING CONSTRUCTION THE CONTRACTOR IS RESPONSIBLE TO VERIFY THAT ALL REQUIRED PERMITS AND APPROVALS HAVE BEEN OBTAINED FROM ALL REGULATORY AUTHORITIES AND SHALL BE THOROUGHLY FAMILIAR WITH CONDITIONS OF SAID PERMITS AND INSPECTION REQUIREMENTS. 27. THE CONTRACTOR SHALL CONTACT ALL OVVNERS OF EASEMENTS, UTILITIES AND RIGHT-OF-WAYS, PUBLIC OR PRIVATE, PRIOR TO WORKING IN THESE AREAS. 28. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO ANY EXISTING ITEM AND/OR MATERIAL INSIDE OR OUTSIDE THE CONSTRUCTION LIMITS. 29. CONTRACTOR SHALL MAINTAIN THE SITE IN A MANNER SO THAT WORKMEN AND PUBLIC ARE PROTECTED FROM INJURY. 30. LANDDESIGN SHALL NOT BE IN CONTROL OR CHARGE OF, AND SHALL NOT BE RESPONSIBLE FOR ACTUAL CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES, OR SAFETY PRECAUTIONS IN CONNECTION WITH THE WORK, OR FOR THE ACTS OR OMISSIONS OF CONTRACTORS OR ANY OTHER PERSONS NOT UNDER THE EMPLOYMENT OF LANDDESIGN. 31. SHOULD THE CONTRACTOR ENCOUNTER ANY ADDITIONAL ITEMS THAT MAY REQUIRE DEMOLITION (FENCES, GUARD RAIL, ETC.) - THE CONTRACTOR SHALL CONTACT THE ENGINEER FOR FURTHER DIRECTION. EXISTING TREATMENT PLANT TO REMAIN IN OPERATION AT ALL TIMES. REFER TO CONSTRUCTION SEQUENCE FOR ADDITIONAL PHASING INFORMATION. CONTRACTOR TO COORDINATE ALL ACTIVITIES WITH TREATMENT PLANT OWNER AND ON -SITE OPERATOR BEFORE YOU DIG! CALL 1-800-632-4949 N.C. ONE -CALL CENTER allrOMMrill111111111111111111 co edE 0, A I. I..1.1.1.ITE::/.//z4::„. FINAL DRAWING - FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION <-1 L'ci5z U-1 w 6-r F- L,t-1 LU Z < Z < 0 ,c12 1TION PLAN PHASE 0 -05 DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 -- --'' ; //// f // 1 / 1 iiiiiiiiiii Ili -;-----_____-.>";;---1---7--- --_--17-----_--= -'zv .--- /i//.4./. I ;.---------_,:::<\Nccy ''-----,--- -------<;i7--,, "../2. _:_<__:,--___.______,,___-_,NN\\ \ \Ny \ A \---,----, ,,..... //,...„ i , \\\\\\\,,,t , rr,„,,,i_ / :-_-_-:---_,- �-- \\� \\ \�\ \\\ i \e ` _... - ..--\ \\ \ \ , , EX. CL CONTACT TANK \i," --- ^ry `\\ `� \\\� , \ , TO BE REMOVED \ �� \ \ \ \\ \\\\\\ \` \ 1 \ \ IASi; 2) \ �� \\ \\\ \� , \ \ � \\\ EX. CHEMICAL FEED BUILDING I '\~\\ \, ,\ ; \\ \\\ TO BE REMOVED ' \\ \\\ \ \ \\ \ \ i(P S` 2) \\ \J \\ \\ \\ \\ \\�\� \�\t\111��1�1 }! \ \\\ \ `\� \ \ \\ \ \ \\ \ EX. CL O BE REMOVED \\\ \\\\ \\ \ ,\ \� \\ \\ ` \ (PHASE 2) } x \\ \\ � \\ \ I# 11"l ; o\1\\ \11 \\\\ �1\\\1\ I I f 1; iIf ( I 1 i\\\\\I\ ill 1 J ! " ji 1"111 EX. EFFLUENT PIPE TO OUTFALL 1 I 1 1 j I J (APPROXIMATE ALIGNMENT) I j CONTRACTOR TO VERIFY LOCATION /f ill f AND DEPTH PRIORTOTHE START 1//"/'f(/»»/tjli1J OF ANY CONSTRUCTION ACTIVITIESr1iti f1ii Ilijill 1 1!1 ! I �! f III �lJ lf 1IicOR rl1 t {f� / /%% f EX. CI ILORINEFEED BWLDIN/1 11111111 1 I / !// ))/ / TO BE REMOVED I ill 1 r J/ 1,1 �� / /� I Iii 'Iii EI Iiii (PHASE 2) l I /11 111 111 11, 11 lf, l 1, ; // / %/ /1,:11111111 11111111 1 11 ,///�/ /�//}/ 11(1,I11 1111 / // / I I1 1Mil 11 l l , l} 11 I-/ // //// � /f !1 1 1111,11 , ,11 ,lll I l/ / // ll l)J I I 1 /J 11, 11, 11 { 7 1// 1 /'/ }//// / /V /// //;// i /f/)/,1f /1))//I/1/// /// i////fir4�j/r i / / // //4/ \ /'/i�/l/////(/I \ / / �i // // / g//1/////4/ \ I 1 '! i `////// /} VII\ I A ♦\ \ ♦`N\ N� \ \ \ N N \ N NN \ \\\ \ \\ \ \ \ \ \�\ \`\ \ \\ N N `~ \ \ \ N \ \ • N U . \ \ \ c� \ N. . Gem RF •` ;1 4` \` - - -'" V \ �ii `_4 i `� N \ \ \\ \ \ � _ \ ~\. _ \ \ \ N \ �_ ,\ ` N.\ \ �N\\\ ` ` `,�� N \ N \_ EX. GRAVEL (TYP) ... N 2//// //// % // / / l / // � f" \�\ //� f /8.1 / \k 7/// \\‘ \\\ \\.‘ \\.\\ //7 ///r 1 p�00\ 1 i /4 7///,' /// /Pi/ 111111 I ////�/// - EX. 15" CMP (TYP) ALIGNMENT NOT FIELD LOCATED s� \ N N N NN \ N \ \\\ \ \ \ \ \ \ `Fab \ \` 1 `\ _` _• �__ �,. \ `?'pO\ \ \ N \ N N \ \'N...,,,,\ \ + \ \ LIMITS OF SURVEY(TYP) `� _\ _ ,� '\ \ \ N .-� t t! ( \ EX. SSMH-1 (TO REMAIN) --.._ 1\ \ EX. AEROBIC DIGESTER TO BE REMOVED (PHASE 2) .2\\\`' \\N\. Ss Op LIMITS OF SURVEY(TYP) 2600 EX. FLOW DISTRIBUTION N Grcp - --- 4, ` \ `•� G4, -\ W// ->4\\\ \ • • N k`k\\\\\ 0// V\\\ LEGEND and NOMENCLATURE SYMBOLS • • • o@g C ®onono -0- Ex. iron pipe/rod or nail Ex. concrete monument New iron pipe Calculated point Cable pedestal Telephone pedestal Electric pedestal Fiber-optic marker Traffic signal box Water meter Fire hydrant Valve (water or gas) Sanitary sewer manhole Sanitary sewer cleanout Storm curb inlet Drainage inlet (w/ grate) Storm drain manhole Utility pole Lamp post Signal pole Guy wire Sign post LINETYPES OU SS Fence Overhead utility Water Sanitary sewer Storm drain Ex. Major Contour Ex. Minor Contour ABBREVIATIONS DB PB or BM N/F Pg. SF Ac. RNV NCSR NCDOT RNV Ex. RCP PVC (M) (P) (D) Deed Book Plat Book I Book of Maps Now or formerly Page Square feet Acres Right-of-way North Carolina State Route NC Dept. of Transportation Right-of-way Existing Reinforced concrete pipe Polyvinyl chloride pipe Measured Platted Deed LOCATION MAP (NTS) DEMOLITION NOTES: 1 EXISTING TREATMENT PLANT TO REMAIN IN OPERATION UNTIL PROPOSED SBR AS BEEN FULLY TESTED AND IS RELIABLY PRODUCING EFFLUENT WITHIN THE CURRENT PERMIT LIMITS. 2. REFER TO CONSTRUCTION SEQUENCE FOR ADDITIONAL PHASING INFORMATION. CONTRACTOR TO COORDINATE ALL ACTIVITIES WITH TREATMENT PLANT OWNER AND ON -SITE OPERATORS 3. CONTRACTOR SHALL SUBMIT DEMOLITION SCHEDULE AND RECYCLING PLAN TO OWNER PRIOR TO PROCEEDING WITH DEMOLITION ACTIVITIES. 4. EXTENT OF SITE CLEARING IS SHOWN ON EROSION CONTROL PLANS. 5, CONDUCT SITE DEMOLITION OPERATIONS TO ENSURE MINIMUM INTERFERENCE ADJACENT OCCUPIED OR USED FACILITIES. DO NOT CLOSE OR OBSTRUCT DRIVEWAY, WALKS OR OTHER OCCUPIED OR USED FACILITIES WITHOUT PERMISSION FROM THE OWNER. 8. ALL PROPERTY AFFECTED BY THIS WORK SHALL BE RESTORED TO A CONDITION EQUAL TO OR BETTER THAN THE EXISTING UNLESS OTHERWISE SPECIFICALLY EXEMPTED BY THESE PLANS. 7. REMOVE WASTE MATERIALS AND UNSUITABLE AND EXCESS TOPSOIL FROM PROPERTY AND DISPOSE OF OFF -SITE IN A LEGAL MANNER. (PERMIT REQUIRED FOR OFF-S1TE DISPOSAL) 8. LOCATE EXISTING ABOVE GROUND AND UNDERGROUND UTILITIES IN AREAS OF WORK. IF UTILITIES ARE TO REMAIN IN PLACE, PROVIDE ADEQUATE MEANS OF SUPPORT AND PROTECTION DURING DEMOLITION OPERATION. 9. SHOULD UNCHARTED, OR INCORRECTLY CHARTED PIPING OR OTHER UTILITIES BE ENCOUNTERED DURING DEMOLITION, CONSULT PROJECT ENGINEER AND UTILITY OWNER FOR IMMEDIATE ACTION. 10. DEMOLISH AND COMPLETELY REMOVE FROM SITE MATERIAL INDICATED ON PLAN OR NOTED "TO BE REMOVED". ALL MATERIAL SHALL BE SEPARATED AND RECYCLED TO THE GREATEST EXTENT POSSIBLE. CONTRACTOR SHALL KEEP AN ACCURATE DISPOSAL AND RECYCLING RECORD INCLUDING WEIGHTS AND VOLUMES OF ALL DEMOLISHED MATERIAL. 11. CONTRACTOR TO PROVIDE THE OWNER WITH A RECYCLING PLAN PRIOR TO THE START OF CONSTRUCTION. 12. PROTECT STRUCTURES, UTILITIES, SIDEWALKS, PAVEMENTS, AND OTHER FACILITIES FROM DAMAGE CAUSED BY SETTLEMENT, LATERAL MOVEMENT, UNDERMINING, WASHOUT AND OTHER HAZARDS CREATED BY THE DEMOLITION OPERATION. 13. CONTRACTOR SHALL RESTORE ALL DISTURBED AREAS TO EXISTING CONDITIONS OR BETTER. 14. CONTRACTOR SHALL MAINTAIN POSITIVE STORM DRAINAGE DURING CONSTRUCTION TO INSURE NO DAMAGE TO ADJACENT PROPERTIES OCCURS DURING STORM EVENTS. 15. CONTRACTOR TO REMOVE ALL VISIBLE OR REASONABLY IDENTIFIABLE MATERIAL, EQUIPMENT, ETC. FROM THE SITE IF NOT NEEDED FOR NEW CONSTRUCTION. 16. THE CONTRACTOR IS CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS ARE BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES, PREVIOUS DESIGN DOCUMENTS, AND WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE LOCATION OF EXISTING UTILITIES MUST BE VERIFIED IN THE FIELD BY THE CONTRACTOR PRIOR TO CONSTRUCTION. 17. ALL DEMOLITION AND CONSTRUCTION SHALL COMPLY WITH APPLICABLE BUILDING CODES AND LOCAL RESTRICTIONS. THE CONTRACTOR MUST COMPLY WITH ALL OF THE CONTRACTOR REGISTRATION REQUIREMENTS OF ALL GOVERNING AUTHORITIES. 18. PRIOR TO THE COMMENCEMENT OF DEMOLITION, THE CONTRACTOR SHALL COORDINATE HIS ACTIVITIES WITH ALL UTILITY COMPANIES SERVING THIS AREA. THE CONTRACTOR IS TO COORDINATE FULLY WITH THE UTILITY COMPANIES ON THE EXACT LOCATION OF ALL UNDERGROUND UTILITIES PRIOR TO DEMOLITION, CONSTRUCTION, AND EXCAVATION. 19. MINIMUM DEPTH FOR REMOVAL OF ALL OBJECTS SHALL BE THREE (3) FEET BELOW GRADE. THE CONTRACTOR IS RESPONSIBLE FOR PROPER RECYCLING AND/OR DISPOSAL OF ALL WASTE MATERIAL. 20. ALL PAVING REMOVAL AND DEMOLITION SHALL BE PERFORMED AS SHOWN ON THE PLANS OR AS DIRECTED BY THE ENGINEER OR OWNER. 21. RELOCATION OR REMOVAL OF OVERHEAD OR UNDERGROUND UTILITIES SHALL BE COORDINATED WITH THE APPROPRIATE UTILITY COMPANY. RELOCATION OR REMOVAL OF EXISTING UTILITIES SHALL BE DONE BY OTHERS AND PAID FOR BY CONTRACTOR UNLESS PREVIOUS NEGOTIATIONS HAVE BEEN MADE WITH OWNER. 22. CONTRACTOR SHALL REMOVE THE EXISTING LIGHT POLE IN THE DEMOLITION AREA AT THE OWNERS DIRECTION. 23. ALL PROPOSED PAVEMENT CUTS SHALL BE SAW CUT ONLY. 24. CONTRACTOR SHALL PROVIDE A MINIMUM OF 72 HOURS ADVANCE NOTICE TO THE OWNER PRIOR TO STARTING DEMOLITION ACTIVITIES. 25. CONTRACTOR SHALL VERIFY AND PROTECT ALL PUBLIC AND PRIVATE UTILITIES. ANY WORK ASSOCIATED WITH SAID UTILITIES TO BE COORDINATED WITH APPROPRIATE UTILITY COMPANY 26. THE CONTRACTOR SHALL IMMEDIATELY REPORT TO THE OWNER AND ENGINEER ANY DISCREPANCIES FOUND BETWEEN ACTUAL FIELD CONDITIONS AND CONSTRUCTION DOCUMENTS AND SHALL WAIT FOR INSTRUCTIONS PRIOR TO PROCEEDING. 27. PRIOR TO BEGINNING CONSTRUCTION THE CONTRACTOR IS RESPONSIBLE TO VERIFY THAT ALL REQUIRED PERMITS AND APPROVALS HAVE BEEN OBTAINED FROM ALL REGULATORY AUTHORITIES AND SHALL BE THOROUGHLY FAMILIAR WITH CONDITIONS OF SAID PERMITS AND INSPECTION REQUIREMENTS. 28. THE CONTRACTOR SHALL CONTACT ALL OWNERS OF EASEMENTS, UTILITIES AND RIGHT-OF-WAYS, PUBLIC OR PRIVATE, PRIOR TO WORKING IN THESE AREAS. 29. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO ANY EXISTING ITEM AND/OR MATERIAL INSIDE OR OUTSIDE THE CONSTRUCTION LIMITS. 30. CONTRACTOR SHALL MAINTAIN THE SITE IN A MANNER SO THAT WORKMEN AND PUBLIC ARE PROTECTED FROM INJURY. 31. LANDDESIGN SHALL NOT BE IN CONTROL OR CHARGE OF, AND SHALL NOT BE RESPONSIBLE FOR ACTUAL CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES, OR SAFETY PRECAUTIONS IN CONNECTION WITH THE WORK, OR FOR THE ACTS OR OMISSIONS OF CONTRACTORS OR ANY OTHER PERSONS NOT UNDER THE EMPLOYMENT OF LANDDESIGN. 32. SHOULD THE CONTRACTOR ENCOUNTER ANY ADDITIONAL ITEMS THAT MAY REQUIRE DEMOLITION (FENCES, GUARD RAIL, ETC.) - THE CONTRACTOR SHALL CONTACT THE ENGINEER FOR FURTHER DIRECTION. SECURITY FENCE NOTE: EXISTING SECURITY FENCE AROUND THE PERIMETER OF THE PROJECT SHALL REMAIN IN PLACE DURING CONSTRUCTION. CONTRACTOR SHALL ADJUST FENCE LOCATION AND ADD ADDITIONAL FENC1NG/GATES, AS NEEDED, AS CONSTRUCTION PROGRESSES. SECURITY FENCE TO REMAIN UPON COMPLETION OF THE PROJECT. BEFORE YOU DIGI CALL 1-800-632-4949 N.C. ONE -CALL CENTER IT'S THE LAW/ co 0 co o v. Olin I Willi,. CORPORATE • 9/19/2017 FINAL DRAWING - FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION < Z 0 Etfi uj Z < 0 DEMOLITION PLAN - PHASE 2 0 DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 N/F 8583-57-1211-000 KER MARTI D & DEBBIE S / DB/PG 442/446 • • / • • \ \ ` • \ \ 1\ / / 9/ • • • • / ♦ ♦ / PROP. 32' X 40' STORAGE BUILDING SEE BUILDING #1 PROP.CHAIN LINK FENCE (TYP) PROP. FLOW MONITORING MANHOLE PROP. 36' X 56' FILTER & UV DISINFECTION BUILDING SEE BUILDING #3 PLANS 0 • • • ♦ ♦ • ♦ • N/F 8583-56-1577-000 TRANSYLVANIA UTILITIES DB/PG 290/429 EX. CHAIN LINK FENCE (TYP) \ r� PROP. BACK-UP GENERATOR REFER TO ELECTRICAL PLANS FOR DETAILS N/F 8583-46-6512-000 GWYNN VALLEY CAMP LLC DB/PG 379/279 • N N N N N \ •� N 4 V • 4 PROP. GATE CONTINUATION OF EX. FENCE NOT SURVEYED 10' X 24' SHED PIPE STORAGE AREA EX. GATE TO REMAIN EX. EDGE OF GRAVEL,TYP EX. EOP, TYP PROP. DRIVE AISLE CENTER LINE (TYP) X • 4. • \ \ �-- x ---_. PROP. 24' X 36' OFFICE SEE BUILDING #4 PLANS PROP.CHAIN LINK FENCE (TYP) N/F 8583-56-6509-000 CORBY DAVID J & SUSAN A DB/PG 477/730 PROP. EDGE OF PAVEMENT CONTINUATION OF EX. FENCE NOT SURVEYED PROP. 28' X 52' BLOWER, PUMP, & PLANT CONTROL BUILDING SEE BUILDING #2 PLANS • EX. CHAINLINK FENCE (TYP) • PROP.CHAIN LINK FENCE (TYP) PROP. SEQUENCING BATCH REACTOR PROP. RETAINING WALL SEE GRADING PLAN FOR — ADDITIONAL INFORMATION PROP. GATE 0 i s b PROPERTY BOUNDARY TYP. 50' SETBACK EX. DRIVEWAY 50'SETBACK \ \ PIPING NOTE: PIPING FROM THE PUMP BUILDING TO THE SBR SHALL BE CLASS 350 DIP PIPING FROM THE SBR TO THE FILTER ROOM SHALL BE CLASS 350 DIP ALL EXPOSED PIPING ON PLANT EQUIPMENT SHALL BE INSULATED AND HEAT TRACED. CONTRACTOR SHALL COORDINATE WITH MANUFACTURER DURING STARTUP AND COMMISSIONING TO ENSURE THAT INSULATION IS PROVIDED WHERE REQUIRED AND DOES NOT INTERFERE WITH THE OPERATION OR MAINTENANCE OF THE EQUIPMENT. SECURITY FENCE NOTE: EXISTING SECURITY FENCE AROUND THE PERIMETER OF THE PROJECT SHALL REMAIN IN PLACE DURING CONSTRUCTION. CONTRACTOR SHALL ADJUST FENCE LOCATION AND ADD ADDITIONAL FENCING/GATES, AS NEEDED, AS CONSTRUCTION PROGRESSES. SECURITY FENCE TO REMAIN UPON COMPLETION OF THE PROJECT. • \ ♦ • • ♦ NOTES: 1. CONTRACTOR SHALL ENSURE ALL PERMITS/APPROVALS HAVE BEEN OBTAINED PRIOR TO THE BEGINNING OF CONSTRUCTION. 2. THE OWNER SHALL PROVIDE THE FOLLOWING EQUIPMENT TO BE INSTALLED BY THE CONTRACTOR: (1) SEQUENCING BATCH REACTOR PACKAGED TREATMENT PLANT IN A CIRCULAR STAINLESS STEEL TANK. THE TANK AND INTERNAL COMPONENTS SHALL BE INSTALLED BY THE MANUFACTURER. ALL CONNECTIONS TO THE PLANT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. 2.1. (1) SBR SYSTEM CONTROL PANEL 2.2. (1) MAGNETIC FLOW METER & AUTOMATIC CONTROL VALVE TO CONTROL POST EQUALIZATION TANK OUTFLOW. 2.3. (16) AUTOMATIC CONTROL VALVES REQUIRED FOR SBR INFLUENT, FLUSHING, SLUDGE RETURN, AND EFFLUENT CONTROL. 2.4. (1) UV DISINFECTION SYSTEM INCLUDING CONTROL PANEL 2.5. (1) TERTIARY FILTER SYSTEM INCLUDING CONTROL PANEL AND AIR COMPRESSOR 2.6. (1) PACKAGED FLOW MONITORING MANHOLE. 2.7. (1) VERTICAL INFLUENT SCREEN INCLUDING BYPASS FLOW CHANNEL TO BE INSTALLED AT THE EXISTING LIFT STATION. 3. THE OWNER WILL PROVIDE THE CONTRACTOR WITH SHOP DRAWINGS AND O&M MANUALS FOR THE OWNER SUPPLIED EQUIPMENT PRIOR TO THE START OF CONSTRUCTION. THE CONTRACTOR SHALL BE FAMILIAR WITH ALL SECTIONS RELATING TO INSTALLATION INCLUDING THE REQUIRED WATER AND ELECTRICAL CONNECTIONS PRIOR TO THE START OF CONSTRUCTION. 4. ALL EXTERIOR EXPOSED PIPING SHALL BE INSULATED AND HEAT TRACED. CONTRACTOR SHALL COORDINATE WITH APPROPRIATE MANUFACTURER PRIOR TO CONSTRUCTION AND DURING STARTUP AND COMMISSIONING TO ENSURE THAT INSULATION IS PROVIDED WHERE REQUIRED AND DOES NOT INTERFERE WITH THE OPERATION OR MAINTENANCE OF THE EQUIPMENT. 5. ALL FITTINGS SHALL BE FLANGED AND SECURED WITH STAINLESS FASTENERS. 6. ALL FASTENERS (BOLTS, NUTS, AND ANCHORS) ARE TO BE 316 STAINLESS STEEL. 4. THE ELECTRICAL SERVICE SHALL BE IN ACCORDANCE WITH LOCAL UTILITY SPECIFICATIONS. SHOP DRAWINGS SHALL BE PROPERLY SUBMITTED FOR APPROVAL. 5. ALL EXTERIOR CONDUIT AND CONNECTORS/HARDWARE TO BE RIGID CONDUIT AS SHOWN AND SPECIFIED ON THE ELECTRICAL PLANS. ADDITIONAL NOTES: 1. APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENT PROPERTIES. WHEN FIELD CONDITIONS WARRANT OFF -SITE GRADING, PERMISSION MUST BE OBTAINED FROM THE ADJACENT PROPERTY OWNERS. 2. NO ON -SITE DEMOLITION LANDFILLS (STUMP HOLES) WILL BE LOCATED ON THIS SITE. 3. ANY DISCREPANCIES FOUND IN THE FIELD OR APPARENT ERRORS IN THESE PLANS SHALL BE CALLED TO THE ATTENTION OF THE OWNER AND ENGINEER PRIOR TO PROCEEDING WITH WORK. 4. PRIOR TO BEGINNING CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY THAT ALL REQUIRED PERMITS AND APPROVALS HAVE BEEN OBTAINED FROM ALL REGULATORY AUTHORITIES. 5. CONTRACTOR SHALL MAINTAIN THE SITE IN A MANNER SO THAT WORKMEN AND PUBLIC ARE PROTECTED FROM INJURY. 6. THE CONTRACTOR SHALL CONTACT ALL OWNERS OF EASEMENTS, UTILITIES AND RIGHT-OF-WAYS, PUBLIC OR PRIVATE, PRIOR TO WORKING IN THESE AREAS. 7. THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THE PLANS IS BASED ON THE RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANY AT LEAST 48 HOURS BEFORE ANY TRENCHING OR EXCAVATION TO REQUEST EXACT FIELD LOCATION OF UTILITIES. FOR ASSISTANCE WITH FIELD LOCATION OF EXISTING UTILITIES THE CONTRACTOR CAN CONTACT NC ONE CALL CENTER AT 1-800-632-4949. 8. THE CONTRACTOR 1S RESPONSIBLE FOR DAMAGE TO ANY EXISTING ITEM AND/OR MATERIAL INSIDE OR OUTSIDE THE CONSTRUCTION LIMITS. 9. DO NOT SCALE DRAWING FOR ACTUAL DIMENSIONS AS IT IS A REPRODUCTION AND SUBJECT TO ERROR. 10. UNDER NO CIRCUMSTANCES SHALL WATER BE PERMITTED TO RISE IN UN-BACKFILLED TRENCHES AFTER THE PIPE HAS BEEN PLACED. 11. THE CONTRACTOR SHALL DO THAT WHICH IS NECESSARY TO CONTROL EROSION AND TO PREVENT SEDIMENTATION DAMAGE TO ALL ADJACENT PROPERTIES AND STREAMS IN ACCORDANCE WITH THE APPROPRIATE CITY/COUNTY/STATE SEDIMENT AND EROSION CONTROL ORDINANCE. 12. BEFORE YOU DIG STOP, CALL THE PALMETTO UTILITY PROTECTION SERVICES INC. AT 1-888-721-7877. ITS THE LAW. 13. SEE STRUCTURAL AND ELECTRICAL PLANS FOR ADDITIONAL INFORMATION 14. SITE CONTRACTOR SHALL COORDINATE WITH ELECTRICAL & PLUMBING SUB -CONTRACTORS AND VERIFY ALL EQUIPMENT DIMENSIONS TO CONFIRM THE LOCATIONS AND SIZES OF ALL ELECTRICAL AND PLUMBING CONNECTIONS PRIOR TO THE START OF CONSTRUCTION. PROPERTY BOUNDARY TYP. ------------------------------------ --------------------------------------------------------------------------- --------------------------------- -------------- US ROUTE 276 - GREENVILLE HWY.—^-- -- T-- (60' PUBLIC ROW) C3 ca CO CD d6") lf) \ I �(U —45 1 in a co PROPERTY BOUNDARY TYP. Si MI la SEE CHAPTER 10 EX. LIFT STATION BUILDING EX. BAR SCREEN fat °ao MONEMEMME 1 1 I, N/F 8583--65-1748-000 FENNIM❑RE JOHN A & ANN MARIE DB/PG 344/430 1 L cLt V en t M ey US u: 1"s�» gAN, •ram> CORPORA'[ ..SEAL /it2 C AV; fn. 4,0 / s I L. 77. 6988 Agr•F,�vIN6�E�. 9/19/2017 FINAL DRAWING - FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION -------------- ---------------- N/F 8583-56-1084-000 TRANSYLVANIA COUNTY DB/PG 523/265 ----------------------- --------------------------- N/F 8583-56-1084-000 TRANSYLVANIA COUNTY DB/PG 523/265 ----------------------------- N/F 8583-55-3841-000 BRACKEN ERNEST LEROY JR HLTE DB/PG 710/720 N/F 8583-55-6677-000 SHETLER THOMAS V & PITTMAN SUSAN K DB/PG 678/016 a ------------------------------- MO170011:111110000MOMOMM 20' 0' 20 40 80 G.. V <zo Wz Wwti w WU i... W�Q z Zz gu SITE LAYOUT OVERALL 0 cc CD rrl DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 PROP.CHAIN LINK FENCE (TYP) EX. 15" CMP (TYP) ALIGNMENT NOT FIELD LOCATED PROP. 32' X 40' STORAGE BUILDING (SEE BUILDING #1 PLANS) PROP. 5' X 18' CONCRETE APRON /\) PROP.CHAIN LINK FENCE (TYP) PROP. LEVEL SPREADER SEE STORM DRAINAGE PLANS 1 PROP. 36' X 56' FILTER & UV DISINFECTION BUILDING (SEE BUILDING #3 PLANS) } PROP. 10' X 20' CONC. PAD FOR BACK-UP GENERATOR PROP. BACK-UP GENERATOR REFER TO ELECTRICAL PLANS FOR DETAILS EX. CHAIN LINK FENCE (TYP) 36.00' BUILDING 3 PROP. GATE BUILDING 1 56.00' 10' X 32' SHED PIPE STORAGE AREA GRAVEL ;':" , . _ :, ,..." (SEE SHEET C3;5�FOR• :"� :.� TYPICAL. SECTION),. R8.00' CONTINUATION OF EX. FENCE NOT SURVEYED PROP. DRIVE AISLE CENTER LINE (TYP) PROP. 5' CONC. SIDEWALK, TYP SEE SHEET C3.5 R5.00 44.50' f X EX. GATE TO REMAIN EX. EOP, TYP PROP. 2'-6" C&G, TYP SEE SHEET C3.5 X PROP. CURB TAPER SEE SHEET C3.5 PROP. EDGE OF 22' DRIVE AISLE (TYP) PROP. EDGE OF PAVEMENT (TYP) R60.00' BLOWER AREA BUILDING 2 PROP RETAINING WALL DESIGN BY OTHERS SEE STRUCTURAL PLANS BUILDING 4 — PROP. 24' X 36' OFFICE (SEE BUILDING #4 PLANS) EX. EDGE OF GRAVEL - -� EX. EDGE OF GRAVEL,TYP CONTINUATION OF EX. FENCE NOT SURVEYED 0 PUMP ROOM R52.16' PROP.CHAIN LINK FENCE (TYP) EX. EOP, TYP 50.00' PROP. 28' X 52' BLOWER, PUMP, & PLANT CONTROL BUILDING (SEE BUILDING #2 PLANS) DIGESTER POST EQ PROP. CONC. PAD FOR SLUDGE REMOVAL CONNECTION SEE SHEET C6.9 EX. CHAINLINK FENCE (TYP) PROP. SEQUENCING BATCH REACTOR R50.00' " R52.16' R94.00' PROP. LEVEL SPREADER SEE STORM DRAINAGE PLANS PROP. RETAINING WALL SEE GRADING PLAN FOR ADDITIONAL INFORMATION PROP. SECONDARY ACCESS ROAD SEE SHEET C3.5 L"10.34' ". �• Op"53.8'V� R"50.00'' EX. STORM DRAINAGE EX. OVERHEAD ELECTRIC FINAL DRAWING - FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION TIE TO EXISTING CONCRETE DRIVEWAY DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 ///_ -�`•�� • EX. 15" CMP (TYP) ���r ^_ . n! ltt Jfl.rnir went C!rl r 1 t t.Arcn \ � \\S \ \\\ \\\\ \\\\\,,N \\\o" \\)\\\\ , /11 fi ,p))) � b���11 o B � � � � �, \\\\\ \\.\\ \\\ \k\\\.„ N N iNv z5 N N EX. GRAVEL (TYP) EX. EFFLUENT PIPE TO OUTFALL (APPROXIMATE ALIGNMENT) CONTRACTOR TO VERIFY LOCATION AND DEPTH PRIOR TO THE START OF ANY CONSTRUCTION ACTIVITIES ss EX. SSMH-2 (TO REMAIN) ss EX. CHLORINE FEED BUILDING TO REMAIN UNTIL PROPOSED PLANT HAS BEEN PLACED INTO SERVICE ts.s SS PROP. STANDBY GENERATOR SEE ELECTRICAL PLANS • 2 ---: --- '''' .-- -... \ \ \ \ \ \ \\\\ N N____ N \ \ \ \ \\ \\ \ \\ \ N '÷r)Z,- '----- \ \ \ \\,..\::,- --, --...,,_ -----....._ \ - ---___ ----,, N` \ \\NN \ \ \ \ \ \ \ \NNN- ' \ \ ,,,,o\N PROP. WATER LINE SEE SHEET C6.0 PROP. TEMPORARY AERATION BASIN INLET SEE SHEET C3.5 10" DIP SEE SHEETS C6.0 - C6.10 10" DIP SEE SHEETS C6.0 - C6.3 \Otr-\6\ LIMITS OF SURVEY(TYP) PROP. RETAINING WALL DESIGN BY OTHERS SEE STRUCTURAL PLANS 2630 Pti EDGE OF GRAVthL V,/ EDGE OF GRAVEL ss a s 1 ! 1 -- �- �. -'1 �-�r• `� \ \ \ \ .r' LANDDESIGN, INC. DOES NOT INTEND FOR THE CONSTRUCTION SEQUENCING NOTES TO DICTATE NOR TAKE RESPONSIBILITY FOR ACTUAL CONSTRUCTION �y �` H MEANS, METHODS, TECHNIQUES, PROCEDURES, AND SAFETY PRECAUTIONS WHICH__ THE CONTRACTOR IS _ � ARE GOVERNED BY LOCAL, STATE AND FEDERAL GUIDELINES, SOLELY RESPONSIBLE FOR ALL CONSTRUCTION RELATED ACTIVITIES ASSOCIATED ...WITH THIS PROJECT. DRAWING IS PROVIDED AS A VISUAL REFERENCE FOR THE FIRST PHASE OF CONSTRUCTION ONLY. SEE SITE, UTILITY, GRADING, AND STRUCTURAL PLANS FOR ADDITIONAL INFORMATION EXISTING SECURITY FENCE AROUND THE PERIMETER OF THE PROJECT - SHALL REMAIN IN PLACE DURING CONSTRUCTION. CONTRACTOR SHALL SECURITY FENCE NOTE: ADJUST FENCE LOCATION AND ADD ADDITIONAL FENCING/GATES, AS 2700 ,7/./ /// /4/ /// — PROP. FORCE MAIN \ / EX. EOP EX. EDGE OF GRAVEL Fxf CALL 1.4300.63 N.C. ONE -CALL CE Ira THE LAW! • NEEDED, AS CONSTRUCTION PROGRESSES. SECURITY FENCE TO REMAIN UPON COMPLETION OF THE PROJECT. DESIGN BY OT SEE -- STRUCTURAL LA I NTIF:4 As L \,\\\\\\\\ \\N s\\ — //////// ////// NNNNNN A \\\.\\\ i\ \\\ </, )1 i \ 7\,,,z;/,/,_///////i7 ,://v//////,/ \\ „ ///77 7,2 /7— \\ /7/ N\ NNN uly //////\ N NN NNN s, PROP LEVEL SPREADER \ • SEE STORM DRAINAGE PLANS INV: 2601.40 N N N N N N • • • N • vc • ticp — PROP SECONDARY ACCESS ROAD \ • CONSTRUCTION SEQUENCE EXISTING TREATMENT PLANT TO REMAIN IN OPERATION AT ALL TIMES. CONTRACTOR TO COORDINATE ALL ACTIVITIES WITH TREATMENT PLANT OWNER AND ON -SITE OPERATOR STEP 1: PERMITS: CONTRACTOR SHALL ENSURE ALL PERM1TS/APPROVALS HAVE BEEN OBTAINED PRIOR TO THE BEGINNING OF CONSTRUCTION. STEP 2: LOCATE ALL EXISTING UTILITIES: CONTRACTOR SHALL IMMEDIATELY REPORT ANY DEVIATIONS FROM ELEVATIONS AND/OR LOCATIONS SHOWN ON THE CONSTRUCTION DOCUMENTS TO LANDDESIGN. PIPE INVERT ELEVATIONS ARE CRITICAL TO DESIGN. CONTRACTOR TO LOCATE EX. UTILITIES AT EACH PROPOSED TIE IN LOCATION AND REPORT ELEVATIONS TO LANDDESIGN PRIOR TO CONSTRUCTION. FIELD ADJUSTMENT OF PIPE INVERT ELEVATION AND/OR LOCATION MAY BE REQUIRED. STEP 3: INSTALL PHASE 1 EROSION CONTROL MEASURES AND CONSTRUCT PROPOSED STORAGE BUILDING (BUILDING 1) STEP 4: PERFORM ROUGH GRADING FOR PROPOSED SECONDARY ACCESS ROAD STEP 5: INSTALL PROPOSED FORCE MAIN. PROPOSED FORCE MAIN MAY BE INSTALLED CONCURRENTLY WITH BUILDING DEMOLITION AND/OR TREATMENT PLANT INSTALLATION. CONTRACTOR SHALL COORDINATE ACTIVITIES WITH PLANT MANUFACTURER AND OWNER. THE CONNECTION OF THE PROPOSED FORCE MAIN TO THE EXITING LIFT STATION SHALL NOT BE MADE AT THIS TIME. STEP 6: REMOVE EXISTING STORAGE BUILDING AND EXISTING SHED: CAREFULLY .DEMOLISH BUILDINGS AS SHOWN ON PHASE 1 DEMOLITION PLAN SEPARATING MATERIALS TO BE REUSED, RECYCLED, OR DISCARDED. STOCK PILE MATERIAL TO BE REUSED AS DIRECTED BY THE OWNER. CONTRACTOR SHALL KEEP ACCURATE RECORDS INCLUDING WEIGHTS AND VOLUMES OF ALL MATERIAL TO BE RECYCLED OR DISCARDED. MATERIAL SHALL BE RECYCLED TO THE GREATEST EXTENT POSSIBLE. STEP 7: INSTALL TEMPORARY FORCE MAIN INLET TO AERATION BASIN: LOCATE EXISTING FORCE MAIN ADJACENT TO THE AERATION BASINS AND INSTALL THE 8" DIP TEE. INSTALL THE TEE AND PIPING AS SHOWN ON THE PHASE 1 CONSTRUCTION SEQUENCE PLAN TO BYPASS THE EXISTING DISTRIBUTION BOX AND DIVERT INFLUENT OVER THE BASIN WALL AND DIRECTED DOWNWARD INTO THE AERATION TANK. COORDINATE THE EXACT LOCATION OF THE TEMPORARY PIPE WITH THE OWNER PRIOR TO THE START OF CONSTRUCTION. STEP 8: MAKE CONNECTION TO EXISTING WATERLINE ADJACENT TO AERATION BASIN. INSTALL THE TEE, THE GATE VALVE, AND CAP EXITING WATER LINE AS NEEDED SO THAT A PORTION MAY BE REMOVED TO AVOID CONFLICT WITH THE PUMP / BLOWER BUILDING REMOVE / RELOCATE ADDITIONAL UTILITIES AS NEEDED ACCORDING TO PHASE 1 DEMOLITION PLAN STEP 9: PERFORM ROUGH GRADING FOR PROPOSED SECONDARY ACCESS ROAD STEP 10: INSTALL PROPOSED FORCE MAIN. PROPOSED FORCE MAIN MAY BE INSTALLED CONCURRENTLY WITH BUILDING DEMOLITION AND/OR TREATMENT PLANT INSTALLATION. CONTRACTOR SHALL COORDINATE ACTIVITIES WITH PLANT MANUFACTURER AND OWNER. THE CONNECTION OF THE PROPOSED FORCE MAIN TO THE EXITING LIFT STATION SHALL NOT BE MADE AT THIS TIME. STEP 11: REMOVE EXISTING GRIT CHAMBER CAREFULLY .DEMOLISH GRIT CHAMBER AS SHOWN ON PHASE 1 DEMOLITION PLAN SEPARATING MATERIALS TO BE REUSED, RECYCLED, OR DISCARDED. STOCK PILE MATERIAL TO BE REUSED AS DIRECTED BY THE OWNER. CONTRACTOR SHALL KEEP ACCURATE RECORDS INCLUDING WEIGHTS AND VOLUMES OF ALL MATERIAL TO BE RECYCLED OR DISCARDED. MATERIAL SHALL BE RECYCLED TO THE GREATEST EXTENT POSSIBLE. STEP 12: PERFORM ROUGH GRADING OF PROPOSED OFFICE LOCATION: CONTRACTOR SHALL ROUGH GRADE OFFICE LOCATION AS SHOWN ON THE GRADING PLAN AND STABILIZE MEDIATE AFTER GRADING HAS BEEN COMPLETED. THIS AREA SHALL REMAIN CLEAR TO BE USED FOR STAGING SEQUENCING BATCH REACTOR (SBR) CONSTRUCTION. STEP 13: PERFORM ROUGH GRADING OF SBR LOCATION AND INSTALL PROPOSED RETAINING WALL. STEP 14: INSTALL TREATMENT PLANT FOUNDATION. INSTALL FOUNDATION ACCORDING TO STRUCTURAL, SITE, AND GRADING PLANS MANUFACTURER WILL INSTALL PLANT COMPONENTS ON FINISHED FOUNDATION STEP 15: COORDINATE INSTALLATION OF TREATMENT PLANT WITH MANUFACTURER: MANUFACTURER WILL INSTALL STAINLESS STEEL TANKS AND PLANT COMPONENTS AS SHOWN IN THE CONSTRUCTION DOCUMENTS AND ALL CONNECTIONS TO THE PROPOSED PLANT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. STEP 16: INSTALL BUILDING FOUNDATIONS AND YARD PIPING INSTALL BUILDING FOUNDATIONS AND PIPING BETWEEN THE PROPOSED SBR AND EACH BUILDING. INSTALL YARD PIPING AS SHOWN ON CHAPTER 6 AND CONDUIT AS SHOWN IN ELECTRICAL PLANS. COORDINATE LOCATION AND REQUIREMENTS WITH SBR MANUFACTURER STEP 17: INSTALL SANITARY SEWER AND STUB BUILDING CONNECTIONS. AS SHOWN ON PIPING PLANS STEP 18: COMPLETE BUILDING CONSTRUCTION: CONTRACTOR SHALL COMPLETE BUILDING CONSTRUCTION ACCORDING TO THE CONSTRUCTION DOCUMENTS AND SPECIFICATIONS. STEP 19: INSTALL ADDITIONAL TREATMENT PLANT EQUIPMENT: CONTRACTOR SHALL INSTALL THE FILTER AND UV DISINFECTION EQUIPMENT ACCORDING THE CONSTRUCTION DOCUMENTS AND MANUFACTURER'S SPECIFICATIONS. CONTRACTOR SHALL INSTALL THE BLOWERS, PUMPS, AND ALL OTHER APPURTENANCES ACCORDING TO THE CONSTRUCTION DOCUMENTS AND MANUFACTURER'S SPECIFICATIONS. AUTOMATIC VALVES CONTROLLED BY THE PLANT CONTROL SYSTEM SHALL BE SUPPLIED BY THE MANUFACTURER, ADDITIONAL EQUIPMENT, MATERIALS AND APPURTENANCES REQUIRED TO INSTALL THE OWNER SUPPLIED EQUIPMENT SHALL BE PROVIDED BY THE CONTRACTOR. STEP 20: COMPLETE ALL TREATMENT PLANT CONNECTIONS STEP 21: TEST THE OPERATION OF INSTALLED ALL PROPOSED EQUIPMENT: CONTRACTOR SHALL TEST THE OPERATION OF THE PROPOSED EQUIPMENT PRIOR PLACING THE SEQUENCING BATCH REACTOR IN TO SERVICE. STEP 22: TEST THE OPERATION OF THE SBR AND PLACE IT INTO SERVICE FOR TESTING. THE CONTRACTOR SHALL COORDINATE WITH THE MANUFACTURER TO PLACE THE SBR INTO SERVICE FOR TESTING AND TRAINING. THE EXISTING PLANT SHALL REMAIN IN WORKING ORDER, READY TO ACCEPT FLOW, UNTIL SUCH TIME AS THE PROPOSED FACILITY HAS BEEN SHOWN TO RELIABLY PRODUCE EFFLUENT THAT IS WITHIN THE EXISTING PERMIT LIMITS. THE CONTRACTOR SHALL NOT BEGIN DEMOLITION OF THE EXISTING FACILITIES UNTIL WRITTEN NOTICE TO PROCEED HAS BEEN OBTAINED FROM THE OWNER STEP 23: PLACE THE SBR INTO SERVICE STEP 24: INSTALL PHASE 2 EROSION CONTROL MEASURES STEP 25: BEGIN DEMOLITION OF EXISTING TREATMENT PLANT: CAREFULLY .DEMOLISH PLANT COMPONENTS AS SHOWN ON PHASE 2 DEMOLITION PLAN SEPARATING MATERIALS TO BE REUSED, RECYCLED, OR DISCARDED. STOCK PILE MATERIAL TO BE REUSED AS DIRECTED BY THE OWNER. CONTRACTOR SHALL KEEP ACCURATE RECORDS INCLUDING WEIGHTS AND VOLUMES OF ALL MATERIAL TO BE RECYCLED OR DISCARDED. MATERIAL SHALL BE RECYCLED TO THE GREATEST EXTENT POSSIBLE. STEP 26: INSTALL STORM DRAINAGE STEP 27: COMPLETE REMAINING UTILITY INSTALLATION STEP 28: FINAL GRADING, SITEWORK, AND PAVING CONTRACTOR SHALL COMPLETE FINAL GRADING, SITEWORK, AND PAVING ACCORDING TO THE CONSTRUCTION DOCUMENTS AND SPECIFICATIONS STEP 29: LANDSCAPING CONTRACTOR SHALL COMPLETE LANDSCAPING ACCORDING TO THE CONSTRUCTION DOCUMENTS AND SPECIFICATIONS STEP 29: PROVIDE AS -BUILT INFORMATION TO OWNER AND ENGINEER CO CORPORATE SIMA LAL SEAL 6988 9/19/2017 FINAL DRAWING - FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION < Z cc zEms 0 0 0. CONSTRUCTION SEQUENCE Prl DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 2605 2600 2595 2590 2585 2580 2575 2570 2565 2560 2555 2550 i ELEV = 2560.3 LIFT STATION LWL 2605 2655 2600 2650 2595 2645 2590 2640 2585 2635 2580 2630 2575 2625 2570 2620 2565 2615 2560 2610 2555 2605 2550 2600 POST EQ DIGESTER REACTOR ELEV = 2650.000 TOP OF TANK ELEV = 2647.500 ELEV = 2647.500 SBR TWL DIGESTER TWL ELEV = 2640.000 SBR LWL ELEV = 2636.830 POST EQ TWL PROP. GRADE FILTER ELEV = 2628.247 POST EQ LWL ELEV = 2628.247 OVERFLOW WEIR ELEV = 2628.080 NORMAL HWL ELEV = 2626.000 SBR REACTOR INLET CIL \ ELEV = 2625.848 ''"'"' NORMAL HWL ELEV = 2625.123 ELEV = 2625.123 UV DISINFECTION CIL IN ELEV = 2625.000 \ CIL OUT //2\ BOTTOM OF REACTOR TANK EX. GRADE ELEV = 2622.533 I* ELEV = 2622 500 \ HWL INFLUENT HWL EFFLUENT ELEV = 2620.500 TOP OF BOX \ ELEV = 2621.343 — at_ INLET ELEV = 2621.343 CIL OUTLET )TEEN = 2620.000 \ ELEV = 2619 935 HWL 1.15 MGD ------- —� HWL 0.90 MGD —\ELEV �v ----- _. �- ��_ = 2619.740 ELEV = 2620.500 i` HWL 0.36 MGD UV/FILTER ROOM FFE ELEV = 2619.502 CIL IN- ELEV = 2619.078 C/L OUT 120* WEIR BOX FOR FLOW MONITORING HWL = HIGH WATER LEVELL LWL = LOW WATER LEVEL HYDRAULIC PROFILE Scale: I" = 30' HORIZ* I I" = 3' VERT. *DISTANCES BETWEEN COMPONENTS NTS 2655 2165 2650 2160 2645 2155 2640 2150 2635 2145 2630 2140 2625 2135 2620 2130 2615 2125 2610 2120 2605 2115 2600 2110 ELEV = 2123.78 HWL POST AERATION ELEV = 2117.78 WL FRENCH BROAD ELEVATIONS FOR POST AERATION FROM ORIGINAL CONSTRUCTION DOCUMENTS, NOT FROM SURVEY 2165 2160 2155 2150 2145 2140 2135 2130 2125 2120 2115 2110 +++Htfikffrr!/// •CORPORATE ..SEAL /!/lrrfffnt�t+++ EAL 6988 ... .. /4•C. Sl++N‘ !!llrriiultt+++ 9/19/2017 FINAL DRAWING — FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION z LL.. O U z w 0 U j 0 i- • DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 EXHAUST FAN, TYP 3280 CFM MIN. TOTAL PLACED IN WALL ABOVE PROPOSED PIPING SEE ELECTRICAL PLAN GRAVEL PROP. BACK-UP GENERATOR REFER TO ELECTRICAL PLANS FOR DETAILS a RETAINING WALL DESIGN _CNNl 2.50' TYP --11-- 4.00' 3.0' M IN P cc. • 0' 0 . atsP o a, Cti X" 22.39' 6.58' 6.58' 4S POST EQ 144 SCFM 10S DIGESTER 240 SCFM SBR CONTROL PANEL 3'-0" PEDESTRIAN DOOR PROP. VERTICAL CLOSE COUPLED (FAIRBANKS-MORSE MODEL B5443) SEE SHEET C6.8 AIR INTAKE LOUVER, TYP CONTROLLED TO OPEN WHEN EXHAUST FAN IS RUNNING LOCATED IN LOWER 1/3 OF WALL HEIGHT LOUVER(S) TO BE SIZED TO MATCH EXHAUST FAN RATING SEE ELECTRICAL, STRUCTURAL, AND UTILITY PLANS FOR ADDITIONAL INFORMATION. ' � .. •t ., ., - , .'; _`.. . ,".e "•">'�`7?p ... ,. '";-CaA,�`. , „ 4�•�b�.:. a�i:..n'fi�'�`:io:4�P:':r.�" . AIR COMPRESSOR, SUPPLIED BY OWNER CLOTH MEDIA FILTER, PROVIDED BY OWNER 3`-0" PEDESTRIAN DOOR 10.5' 10.5' 12.00' 12.00' CAST IRON FLOOR DRAIN, TYP 75 SQ IN MIN FREE AREA 15" TOP, 6" DIA OUTLET JR SMITH 2295 OR APPROVED EQUAL PROP. VERTICAL CLOSE COUPLED PUMP (FAIRBANKS-MORSE MODEL B5444S) SEE SHEET C6.8 56.00' 54.67' 28.00' UV CONTROL PANEL, TYP NOT TO SCALE 10.73' PROP UV DISINFECTION, PROVIDED BY OWNER I I .I 1 1 11;:DISINFECTI' 12.00' ROLL UP DOOR PROP UV DISINFECTION, PROVIDED BY OWNER GRAVEL SBR ` k 34 67' 36.00' PROP FLOW MONITORING WEIR BOX MOUNTED IN SLAB, PROVIDED BY OWNER SEE SHEET C6.10 PROP LAB BENCH DESIGN BY OTHERS SEE BUILDING PLANS FOR ADDITIONAL INFORMATION 2.5' 0' 2.5' 5' 10' EQUIPMENT NOTES: 1. EQUIPMENT TO BE SUPPLIED BY THE OWNER OR SBR MANUFACTURER SHALL BE INSTALLED BY THE CONTRACTOR ACCORDING TO MANUFACTURER'S SPECIFICATIONS. 2. THE OWNER SHALL PROVIDE SHOP DRAWINGS OF THE PROPOSED EQUIPMENT TO THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 3. CONTRACTOR SHALL CONFIRM THAT ALL DIMENSIONS ON THE PROVIDED SHOP DRAWINGS ARE CONSISTENT WITH THOSE SHOWN IN THESE PLANS PRIOR TO THE START OF CONSTRUCTION. 4. DISCREPANCIES SHALL BE REPORTED TO THE OWNER AND THE ENGINEER IMMEDIATELY. BUILDING NOTES: 1. SEE ELECTRICAL, STRUCTURAL, AND BUILDING PLANS FOR ADDITIONAL INFORMATION. 2. SEE UTILITY SHEETS C6.2 & C6.3 FOR ADDITIONAL PIPING LAYOUT INFORMATION 3. SEE SHEETS C6.4 - C6.5 FOR BLOWER BUILDING AERATION PIPING INFORMATION 4. SEE SHEETS C3.0 - C3.2, & C3.5 FOR SITE LAYOUT INFORMATION 5. BUILDING FLOOR DRAINS TO BE TRAPPED AND VENTED PER ALL APPLICABLE CODES. 56.00' 54.67' N. v CAST IRON FLOOR DRAIN, TYP 75 SQ IN MIN FREE AREA 15" TOP, 6" DIA OUTLET JR SMITH 2295 OR APPROVED EQUAL 14.65' _ 14.65' 8.66' 8.75' 8.75' 3'-0" PEDESTRIAN DOOR 8.50' 17.25' 10.57' 26.51' 17.25' —+— *3.38' 34.67' 36.00' 6.17' iiiiiilLONn11111111111111111 2.5' 0' 2.5' 5' 10' 4 UV DISINFECTION BUILDI CORPORATE SEAL - C Ag��````ti AL 6988 '1'/ !N EEF;/1/1/111111 9/19/2017 FINAL DRAWING - FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION 0 Z 5 c0 J_ W 0 Gi Z 0 in cC I LU DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 0'-1„ 4' 0" 0'-1 1/2" 3'-0" SECTION 11-0„ / DIA. STEEL BOLLARD C3i5j, ELEVATION / PLAN f4 1" HIGH CONCRETE TOP SLOPE TO DRAIN 6 1/2" DIA. SCH. 40 STEEL TUBE FILLED WITH 3600 PSI CONCRETE @ 28 DAYS, WELD TUBE TO PLATE BLACK POWDER COAT FINISH (4) 5/8"x18"x2" GALV. STEEL ANCHOR BOLT BLACK POWDER COAT FINISH 13"x13"xl" STEEL MOUNTING PLATE BLACK POWDER COAT FINISH CONCRETE FOOTING 3600 PSI CONCRETE @ 28 DAYS FINISHED GRADE 98% COMPACTED SUBGRADE 7" DIA. BOLT CIRCLE # DESCRIPTION 1. SUBGRADE: COMPACTED SUBGRADE 100% MAX. DRY DENSITY ( STANDARD PROCTOR ) - ASTM D698. 2. SURFACE COURSE - 8" COMPACTED AGGREGATE BASE COURSE. (CABC) TYPICAL GRAVEL SECTION TYPE I TYPICAL PAVEMENT SECTION -GRAVEL C3.5 7(7 SECTION 1/8" RADIUS 2'-6" CURB AND GUTTER CURB AND GUTTER (2'-6") NTS NTS NOT TO SCALE NOTE: MINIMUM SLAB THICKNESS: 6" AS REQUIRED BY GRADE 2 12" MIN ••°-..- (2) #5 REBAR HEAVY DUTY CONCRETE #5 REBAR, 12in O.C. EACH WAY, w/3in MIN. COVER. STOP REBAR 2in FROM CONSTRUCTION JOINTS & EDGE OF SLAB 4in AGGREGATE BASE COURSE, COMPACTED 98% COMPACTED SUBGRADE NOTES: 1. CONTRACTOR MUST VERIFY THIS PAVEMENT SECTION WITH CONSULTING GEOTECH PRIOR TO INSTALLATION.. 2. CONCRETE SHALL BE 3000psi @ 28 DAYS. 3. WATERPROOFING SEALANT TO MATCH CONCRETE COLOR C3.5 SECTION TYPICAL GRAVEL SECTION TYPE I 7M 4X SEE GRADING PLAN �j. 5 C3.5 4.00' # DESCRIPTION 1. SUBGRADE: COMPACTED SUBGRADE 100% MAX. DRY DENSITY ( STANDARD PROCTOR ) - ASTM D698. 2. SURFACE COURSE - 8" COMPACTED AGGREGATE BASE COURSE. ( CABC ) 4.00' - 2.00' \//\/\/\// 12.00' PAVEMENT SCHEDULE (TO BE VERIFIED BY PROJECT GEOTECHNICAL ENGINEER 2.00' 3% +-- 4.00' • 4 4.00' --•- NOTE: SEE GRADING PLAN FOR DITCH LOCATION SECONDARY ACCESS RD. TYPICAL SECTION SECTION DRIVE AISLE 8 CURB TAPER C3.5 ISOMETRIC 2'-6"C&G EDGE OF PAVEMENT BOTTOM OF CURB TOP OF CURB LANDSCAPE AREA OR PAVING 6" TO 0" CONCRETE CURB TAPER NTS SEE GRADING PLAN NTS NOTES: 1. SEE LAYOUT FOR ADDITIONAL INFORMATION. 2. ALL CONCRETE TO BE 3600 PSI @ 28 DAYS. TOP OF CURB FLUSH WITH PAVEMENT PAVEMENT NTS SURFACE COURSE SF9.5A TACK COAT INTERMEDIATE COURSE S9.5A, SF9.5A SEE TABLE BELOW -lc SEE TABLE BELOW SEE TABLE BELOW BASE COURSE COMPACTED AGGREGATE BASE COURSE ASPHALT PAVING NOTE 1. SURFACE COURSE 2" 1-2 SURFACE COURSE 2. INTERMEDIATE COURSE 3" HB BINDING COURSE 2. BASE COURSE 8" C.A. B.C. r 3 SUBGRADE COMPACTED SUBGRADE NOTES: 1. GEOTECHNICAL ENGINEER SHALL REVIEW AND APPROVE ASPHALT PAVEMENT DESIGN PER ACTUAL SOIL CONDITIONS AND OWNERS LOADING REQUIREMENTS. ASPHALT PAVEMENT SECTION SCALE: 3/4" = 1' - 0" TROWEL AND BROOM FINISH, PERPENDICULAR TO TRAVEL 3/2" BIT. EXPANSION JOINT ALLOWY2" RECESS BELOW TOP OF SLAB TO SEAL W/ WATERPROOF SEALANT a' { e II° 4 4 ° a Qyac0o. a cbu ae ° cW O00 OQa O O 900 0 00 00 r�\\i/\//\c/W\\t� 1/8" RADIUS 1/8" TO 1/4" JOINT FILLER 1/2" TRANSVERSE EXPANSION JOINT IN SIDEWALK N.T.S. ( 6 °0 o 1/8" GROOVE JOINT IN SIDEWALK N.T.S. CONCRETE SIDEWALK C3.5 SECTION 3600 PSI CONCRETE @ 28 DAYS CONTROL JOINT TOOLED JOINTS PER SITE PLAN & PLAN ENLARGEMENTS WHEN NOT SHOWN, CONTROL JOINT SHALL BE REQUIRED AT 5' INTERVALS JOINTS TO BE}" RADII X 1" DEEP W/ WATERPROOF SEALANT EXPANSION JOINTS AT INTERVALS OF NOT LESS THAN 30 FEET AGGREGATE BASE COURSE, COMPACTED 95% COMPACTED SUBGRADE NOTES: 1. A GROOVE JOINT 1" DEEP WITH 1/8" RADII SHALL BE REQUIRED IN THE CONCRETE SIDEWALK AT 5' INTERVALS. ONE 1/2" EXPANSION JOINT WILL BE REQUIRED AT 45' INTERVALS NOT TO EXCEED 50' AND MATCHING EXPANSION/CONSTRUCTION JOINT IN ADJACENT CURB. A SEALED 112" EXPANSION JOINT WILL BE REQUIRED WHERE THE SIDEWALK JOINS ANY RIGID STRUCTURE. 2. SIDEWALK AT DRIVEWAY ENTRANCES TO BE 6" THICK. 3. SIDEWALK TO BE POURED TO END OF RADIUS AT INTERSECTING STREETS. 4. WATERPROOF SEALANT TO MATCH CONCRETE COLOR SHALL BE REQUIRED. 5. SIDEWALK SHALL HAVE A LATERAL SLOPE OF ONE -QUARTER INCH PER FOOT. NOT TO SCALE F N N U Z .) N 0 rom U4.4 u- N g C en U Z > CORPORATE SEAL ��rrrrrrirttrtttt SEAL 6988 %4."•FNCENI FQ•'4' 9/19/2017 • • DETAILS -SITE C3.5 SECTION DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 10' 10' 8' 8' 10' RIW O 7" WIRE FENCE TERMINAL POST LINE POST BRACE RAIL TIE WIRE (#6 GA. @ 24" CTRS.) USED TO TIE FABRIC TO BRACE RAIL 3" MIN. 4 3It* • PLAN (LINE POST TERMINAL POST SEQUENCE) TIE ROD .375 DIA. W/TURNBUCKLE 8'-0„ E.;I 1 I I L --I-- TERMINAL POST (SEE GATES FOR GATE POST DIMENSION) 112„ CHAIN LINK FENCE WIRE CLIPS OR TIES TO BE USED TO ATTACH FABRIC TO POSTS AT 12" CENTERS TENSION WERE-#7 GA. LINE POST LINE POST (TYP) HEIGHT VARIES DUE TO DIFFERING MANUFACTURING DIMENSIONS TENSION WIRE 10.-0" THE FABRIC MAY EITHER BE FASTENED TO THE TENSION WIRE BY HOG RINGS SPACED AT 2' INTERVALS, OR THE TENSION WIRE MAY BE WOVEN THROUGH THE FABRIC. I 1 I 1 1 I I 1 LuJ BRACE RAIL TERMINAL POST TENSION WIRE #7 GA. BRACE RAIL LINE POST •�♦�t�r�F���r4.4 Ei?eyt4*�� i'•~r ,•044.4. •r•+t•• r lam• • • • •••• ••• • •• 4 ►•• • • • �•♦ •� 4e,, `• ***♦***•**irk♦44i♦it*,44 P4i•4 4 �414O i �4.4 4*a+w'4*4'*., It, t!,«► +t4*i••��*•*i'.• 1444 '�G1-4t, ••tea*+.- I NOTE: ROLL FORMED LINE POST MAY BE DRIVEN TO A MINIMUM OF 3'-0" IN LIEU OF CONCRETE ANCHOR UNLESS OTHERWISE DIRECTED BY THE ENGINEER. I I 1 I I I 1 11 TIE ROD 0.375 DIA. WITH I 1 I TURNBUCKLE LENGTH OF I THREADS FOR TURNBUCKLE I IS 7" MIN. CUT TIE ROD I IS REQUIRED. gA" so? vhoEs TENSION WERE #7 GA. TERMINAL POST TENSION WIRE #7 GA. BREAK IN FENCE AT THIS POST MAY BE OMITTED IF FENCE CAN BE TAUT WITHOUT BREAKING AND IF OMISSION AND ERECTION ARE APPROVED BY THE ENGINEER. NOTE: CAPS ARE REQUIRED ON PIPE POST. CAPS ARE NOT REQUIRED ON "H" POST OR ROLL FORMED POST . FENCE FABRIC SHALL BE INSTALLED ON THE SIDE FARTHEST FROM THE HIGHWAY EXCEPT THAT ON HORIZONTAL CURVES GREATER THAN THREE DEGREES THE FENCE SHALL BE INSTALLED SO AS TO PULL AGAINST LINE POST. ALL CHANGES IN DIRECTION OF FENCE LINE OF 30" OR MORE SHALL BE CONSIDERED AS CORNERS. METHOD OF CONSTRUCTION FENCE ON SHARP BREAK IN GRADE NTS C3.6 :A '-0" HEIGHT vie PLAN / SECTION GATE POST 0.375" ROUND ROD e•`'*:''di0•'a*t♦Or•41i♦i•♦•04•i«••••• r*i+* f t� �� fin •t•�it'•V.., % ,* ••• •••♦*••iVA* O *rOO•••i•0*�t�ti• ••• •• • •tt •O'•O'ttiq.;.•*. • •sr•♦a♦•�•♦♦ •♦t♦••♦•'♦♦♦*0•• •♦*• :*•••••• **,•,1•` •••••ari*•i*O•••••• **i 4,0 ~• •ic'.•s:*�♦*•'♦*�i•it +i**is•�'A�i'.w*t'i a:are..•••i•1r?.i4 $41:�►+:144 .t* .1'. ***: *♦p�� 1.90" O.D. PIPE 1.90" O.D. PIPE r...r..MMI...rE Pam:•*di•4`4•'i•i•••i•i•it*•ii•••i•i•i•*•••••S*•♦•i'iSOt••••••%-'' • 'i�•i•iti��'*•iitr♦'ii0*!Oi��•i4i*itit�J+pit%4i4�t%Jib �•ti t}ttttt Or:'�•i ii'+�%O��•3+•�*i*i•**i•*tii'ili� I Ot!♦trtrrt .v♦�ltrr♦Otlt•.a •♦rtrtl� IIII•+•i*.a4.•*•-e•yt fitat%* T it•!�•`!tAt• e%�'i•t• w!.t•.t•w'i•*�teili'M triEEi.E,.E� im:unimm:iaEiffewa momme..mimme...�..�A. EI'2 -1 OPENING SECTION NOTE: MAXIMUM WIRE SPACING TO BE 6" MAXIMUM CLEARANCE BETWEEN LOWEST STRAND AND GROUND TO BE 6" BRACE RAILS SHALL BE ERECTED BETWEEN TERMINAL OR GATE POSTS AT INTERVALS NOT EXCEEDING 700' ON TANGENTS OR 350' ON SHORT RADIUS CURVES. ADDITIONAL TERMINAL POSTS SHALL BE ERECTED IF SO DIRECTED BY THE ENGINEER. TERMINAL POSTS SHALL BE BRACED FROM BOTH SIDES OF POST. TO BE USED WHERE SWINGING CLEARANCE IS LIMITED DOUBLE SWING GATE 14" C3.6 ELEVATION NTS NTS FABRIC GALV. STEEL OR ALUMINUM COATED STEEL #11 GAGE ALUMINUM ALLOY OR ALUMINUM COATED STEEL (#11 GAGE) FRAME COMPONENTS GALVANIZED STEEL #11 GAGE ALUMINUM ALLOY SYSTEM G1 G2 G3 Al A2 LINE POST 1.09" O.D. STEEL PIPE 1.625" x 1.875" STEEL H 1.625" x 1.885" STEEL R.F 2.375" O.D. ALUMINUM PIPE 2.00" x 2.50" ALUMINUM PIPE TERMINAL POST (ENBD CORNER, 2.375" O.D. STEEL PIPE 2.375" O.D. STEEL PIPE 2.375" O.D. STEEL PIPE 2.875" O.D. ALUMINUM PIPE 2.875" 0.D. ALUMINUM PIPE GATE POST UP THRU 6' LEAF 2.875" O.D. STEEL PIPE 2.875" O.D. STEEL PIPE 2.875" O.D. STEEL PIPE 2.875" O.D. ALUMINUM PIPE 2.875" O.D. ALUMINUM PIPE GATE POST 7' THRU 12' LEAF 4.000" O.D. STEEL PIPE 4.000" O.D. STEEL PIPE 4.000" O.D. STEEL PIPE 4.000" O.D. ALUMINUM PIPE 4.000" O.D. ALUMINUM PIPE BRACE RAIL 1.660" O.D. STEEL PIPE 1.660" O.D. STEEL PIPE S 2" x STEEEEL R.F OOR R 1.660" O.D. STEEL PIPE 1.660" O.D. ALUMINUM PIPE 1.660" O.D. ALUMINUM PIPE r2 FABRIC GALV. STEEL OR ALUMINUM COATED STEEL #11 GAGE FRAME COMPONENTS GALVANIZED STEEL #11 GAGE SYSTEM G1 G2 G3 LINE POST 2.375" O.D. STEEL PIPE 1.625" x 1.885" STEEL H 1.625" x 1.875" STEEL REF.. TERMINAL POST (END, CORNER, BRACES) 2.875" O.D. STEEL PIPE 2.875" O.D. STEEL PIPE 2.875" 0.D. STEEL PIPE GATE POST UP THRU 6' LEAF 2.875" O.D. STEEL PIPE 2.875" O.D. STEEL PIPE 2.875" O.D. STEEL PIPE GATE POST 7' THRU 12' LEAF 4.000" O.D. STEEL PIPE 4.000" O.D. STEEL PIPE 4.000" O.D. STEEL PIPE BRACE RAIL 1.660" O.D. STEEL PIPE 1.660" O.D. STEEL PIPE 1.250" x 1.625" STEEL R.F OR 1.660" O.D. STEEL PIPE ALLOWABLE COMPONENTS FOR FENCE SYSTEMS LE3:62A NTS AL 6988 9/19/2017 V J z <zo U_ W LIJ Lo WUj w Li cc Z II iIZ ~ Z 0 U O. H v) 0 • DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 \\\\ \\\\N\ \\ \\ \ \ \\ N• //� /// ,f /�/ �" \ \ EX. CHAIN LINK r r� 2635 r �/ !//,1/ /I /// //, ��`�`\ \�\\N FENCE (TYP) � - ��// rl/ / /\1151111 3,1t4S1 / EX. 15" CMP (TYP) % ALIGNMENT NOT / /�� ./1 \\0\\ 630-1. /// ///"--*Y\\ ,\\VA\i\ \\ :4,y/A it/ // -' .1 ././'/-� f /� / ----�` _-- ". sue// / ///_//7/ ��� /��� r. W.7. -'/✓,.- y _ �- '' �// %/� ��/ / \\\\\ \\\ \\\\\\\ „ \;\ \\, \ \ \1' 1 11 ', i1\\\ \�\ 11 A\,,v;\ �li 1 1� \\� \� 1 4'r�, \�, ; 2619.21 \ \\‘‘, \, 1\ , 1�ii�, �u'\1� �\\ LEVEL 1PRE4D,R WEIR \\\°\e\ \\ \\\ \\ 1\ \ \\\I I. II"Ili I fl 26192, j f if LEVEL SIREADEI WEIR \��\ \ 1� \ \ \ BOTT 7 O\ LEVVEL ScRrIkDER \ \ 1 \ \ \ PROP.CHAIN LINK \ FENCE P I 5 LP: 2 ' \ \ 4 2618 92' \y . 1 s S t PROP. GATE N \ NNN \ \ \ \ �✓ �'�� \ \ \ \ \ \ \\\ N N \�\\ \ \\ \\\\\ N / N N \ (7(r ,BW: 2629.10 ���SW: 2629. o5- \\\\ \\\ \\ ~\ \\ \\ \ \ \ \ \\ �� �� �`� `\\��NN \\ \\\\\� \ \\ \ \ \� `\ \ \ \\\ \ \ \� N ,\'''' \ \ \ ` \ \ e"y0 N N -\- „ 5- N y -� \ \ \\ \ \ \ \ \ \\ \ •�--- ` \ \ \ \\\ IIII j' III�II, ,II(/f 11/)1)11'.I\' I 2618.71 11 f I I I! 11� BOTTOM OF LEVEL SPREADER nilIli III II II, I/f -H o IfII11110 ,(lf11f II 1I I,II,I III fl lflj II II,II,III,IIf11f II III, I / l� ��� � f l III i f IIf III! Iflr III If ,w(7//// l l I II"III�IIIfII II Ifs(! ///// // //! IfI fI fI I11 IfII fI IfI /////// /// ///// PROP. FILTER & UV ! ] f f hi/ ff DISINFECTION BUILDING f //// ilfllf II I II fIIiii J'III " f f f/f //l //I'l , / /,/ / / p/ 1 /// I \ \ \ \ \ \ \ \ 1 /ry4/7 ////�/ // / // / / // '///( / \ / *\ / / // �, /// , �j/} I iv i.. , x i, __ _ 'I I , !'/7Mf/x I f , l/,� 1 / �% / tin Ji- / \\ / / ( PROP. BACK-UP GENERATOR f SLAB ELV. = 2620.5 \ 1 f t \\\\ �\ \ x \ \ \ \\ \ / \ I \ x� \-- N x� \ t \ \ ;\ \ \ \ \ \ \ \ \\ \ \\\ \ \ `\ \ \ . \ \\ \ \ `\ \ \ • \ ` ~_ -n \\\ Gv Ito \\\ \ \\ \ N N \ \ �+ l�j� \ •\ \ \ \ \ \\\\ \ plc `� �\ - N 2600 �z • / \ N \ PRQP. EDGE OAF PAV ENT1TYP)\ \ 2631 O6 \ \ _ ._ N _ N N N \ \ N N N� \ N/F 8583-56-6509-000 CURBY DAVID J & SUSAN DB/PG 477/730 —5-- N '— 50.00' N — N --__ PROP. BLOWER, PUMP, & PLANT CONTROL BUILDING - -___ — \ ▪ _ -� N. .2800 N. N 2631.5` PROP. SEQUENCING BATCH REACTOR BOTTOM OF TANK - 2625.0 2631.43 N / " PROP.CHAIN LINK \ . FENCE (TYP) \ /,�'/7/1/ /�� ��\\ N\� / PROP. 24' X 36' OFFICE / / \ / N N N N EX. CHAINLINK FENCE (TYP) N HP: 2632.10 N \ \\ \\ � f/ j �. �\\ \ , \ PROP.RETAINING ALL f c� / / �� \ \ \\\ '�\ �- \\ \ SEE STRUCTURAL PLAN f z // / \ \ \� �. a _ \� `�`�\\ \ \ FOR ADDITIONAL .�// �/ \ \` ` �\ \ ` ` ` \� �_ ` A .�. �`� -- t \t� INFORMATION // // j \ \ N \ \ =. `^�� ` — 2// -. -„:.,--,,...----- -_,=:__ I --_-- // T / // / —— --„:-__ - \�_' ,��'"� �.„--_, _� mow„,,,, ,.- "" 1 1 1 \ k o // 1, „ i , , ) , ,, ---- .7-, //, -------_,-------------.„-------y-T---‘,,,,--- ---, -6,_ ,-__ ,__,___-___. _ ( \ 1 \ \ \ \ \ _v - - - -___.-.>--,-- ---- __,.„ /7_ \ ..-_,:-._ ,-__-__ __ ___,_____ ‘\\\--,:-_-__:::,------____=_----:-----‹ ---___-- ,>;„_._...,„ ........_ ,,_......„.„_________-__ _., __ ._ ____________ , /, // , ,/ ----_, -...., ____-_„. _-_,----, ,..„-----, i / i ) , \ i,1 \---". - // ,,, ,,,,--„----_,---_ „,-;„,,,--_______--,-__,N„.„ „____-___-__-__ ,,,-----. ____:. i\ 11i \1 \ \1 \\ / //lfj � - --„..-- ----- = ____ ___________.--,.. 1 ----- -----�ii\i\ _, ---. -., ---.:' -__.. z / it/ — ------„,:-___ ---__. 0, \\\.... -----, ,.. //,-- 791#7- GRADING NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE TO UNION COUNTY STANDARDS AND SPECIFICATIONS. 2. EXISTING CONTOUR LINES SHOWN ARE BASED ON SURVEY AND GIS. CONTRACTOR TO ADJUST SLOPE TIE OUTS AS NEEDED MAINTAINING PROPOSED SLOPES. 3. SEE STRUCTURAL DESIGN SHEETS FOR SLAB TYPICAL SECTIONS AND ADDITIONAL INFORMATION. 4. APPROVAL OF THIS PLAN IS NOT AUTHORIZATION TO GRADE ADJACENT PROPERTIES. WHEN FIELD CONDITIONS WARRANT OFF SITE GRADING, WRITTEN PERMISSION MUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNERS. 5. NEW FINISHED CONTOURS SHOWN ARE TOP OF PAVING IN AREAS TO RECEIVE PAVEMENT AND TOP OF TOPSOIL IN AREAS TO BE SEEDED. 6. GRADING CONTRACTOR SHALL COOPERATE AND WORK WITH ALL OTHER CONTRACTORS PERFORMING WORK ON THIS PROJECT TO INSURE PROPER AND TIMELY COMPLETION OF THIS PROJECT. 7. THE GRADING CONTRACTOR SHALL USE WHATEVER MEASURES ARE REQUIRED TO PREVENT SILT AND CONSTRUCTION DEBRIS FROM FLOWING ONTO ADJACENT PROPERTIES. CONTRACTOR SHALL COMPLY WITH ALL LOCAL, STATE,AND FEDERAL EROSION SEDIMENT AND SILTATION ORDINANCES. CONTRACTOR SHALL REMOVE ALL TEMPORARY EROSION CONTROL STRUCTURES UPON COMPLETION OF PERMANENT DRAINAGE FACILITIES AND NOT BEFORE ALL AREAS DRAINING INTO THESE STRUCTURES ARE SUFFICIENTLY STABILIZED. 8. GRADING CONTRACTOR SHALL TAKE ALL AVAILABLE PRECAUTIONS TO CONTROL DUST. CONTRACTOR SHALL CONTROL DUST BY SPRINKLING, OR BY OTHER METHODS AS DIRECTED BY ENGINEER AND/OR OWNER'S REPRESENTATIVE AT NO ADDITIONAL COST TO OWNER. 9. GRADING CONTRACTOR TO COMPLY WITH ALL STATE AND LOCAL SEDIMENT CONTROL AND AIR POLLUTION ORDINANCES OR RULES. 10. CONTRACTOR TO COORDINATE ALL WORK WITH OTHER UTILITY INSTALLATIONS NOT COVERED IN THESE PLANS (ELECTRIC, TELEPHONE, GAS, CABLE, ETC.) AND ALLOW FOR THEIR OPERATIONS AND CONSTRUCTION TO BE PERFORMED. CONTRACTOR SHALL REPAIR OR REPLACE IN -KIND ANY DAMAGE THAT OCCURS AS RESULT OF HIS WORK. 11. 1 1 \ z '14," 2625.75 \ BOTTOM OF LEVEL SPREADER 2600 N //AO- --- 2620 28 15 2605 10' 0' 10' 20' 40' CO ID C4 LO rti it o • CORPORATE t sE • 9/▪ .1"1"9"1/2"0"11; FINAL DRAWING - FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION < Z 0 LU LLI Lai (LTI eL Z c= Z < 0 REN3SIONS: L j; ›- • ,.Z:1C (936 • 2 I u j:C7 Ci<CtigUICYLIS1)60-19 liujU DocuSign Envelope ID 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 PROP. DOG HOUSE MANHOLE OVER EXISTING OUTFALL LINE CONTRACTOR TO LOCATE PRIOR TO THE START OF CONSTRUCTION ss ss f` PROP. 10" DIP 1% MIN SLOPE PROP. 304 SS FLOW MONITORING 120° WEIR BOX MOUNTED IN SLAB, PROVIDED BY OWNER PROP. FILTER & UV DISINFECTION BUILDING 1 (SEE STRUCTURAL PLANS) k / k / ss 6" DIP FLOOR DRAIN PIPING SEE BUILDING PLANS FOR INTERIOR DRAIN LOCATIONS AND DETAILS PROP. BACK-UP GENERATOR REFER TO ELECTRICAL PLANS FOR DETAILS SS CLEANOUT, TYP 0+19.03 90' HORIZ. BEND 0+33.71 45" HORIZ. BEND WATER LINE STUB FILTER / UV BUILDING • PROP. SSMH-1 RIM: 2619.85 12' INV. IN: 2605.99 (SSMH-4) 8" INV. IN: 2609.95 (SSMH-2) 12' INV. OUT: 2605.99 (EX SSMH-1) PROP. 2 CY DUMPSTER PROVIDED BY OWNER EX. EX SSMH-2 RIM: 2620.14 12" INV. IN: 2607.99 (TO BE PLUGGED) 12" INV. OUT: 2607.74 (SSMH-4) PROP. SSMH-4 RIM: 2621.94 12" INV. IN: 2606.80 (EX SSMH-2) 10" INV. IN: 2615.84 (10" BEND) 12" INV. OUT: 2606.80 (SSMH-1) 8" DIP FILTER OVERFLOW PIPING MIN SLOPE: 1.5% EX. 12" DIP SS, TYP Irk cst V) PROP. 6" DIP DRAIN 1% MIN SLOPE 3' MIN COVER SEE GRADING PLAN AND SITE PLAN FOR ADDITIONAL INFORMATION PROP. STORM DRAINAGE, TYP SEE STORM DRAINAGE PLANS Gp 0+80,23 11.25' VERT. BEND ClGp X CORE EXISTING MANHOLE PROP. 8" X 10" CONCENTRIC EXPANDER (FJ-FJ) SEE SHEET C6.2 FOR CONTINUATION PROP. CO-1 RIM: 2631.02 6" INV. OUT: 2624.00 (SSMH-3) PROP. EBAA FLEX -TEND° (FJ-FJ) FLEXIBLE EXPANSION JOINT PROP. 21.90 LF OF 6" DIP @ 3.00%,`� ^ w'`S. k `ua.�.%tS.::..:��.si �'ii...�i.^ °, "�v:s�°i,^,'s iCi�.��v'E�v4� F:E<�ic��5� +�•:S'. PROP. 1" WATER LINEy : Z:, '' 3 cif` _;, srF ;•r TIE TO EX. WATER LINE PROP. 8" FORCE MAIN SEE SHEETS C7.0 - C7.3 PROP. SSMH-2 RIM: 2630.35 8" INV. IN: 2621.96 (SSMH-3) 8" INV. OUT: 2621.76 (SSMH-1) PROP. OFFICE (SEE STRUCTURAL PLANS) x--_. X --�_ x x X-._ x \ \ \ \ PROP. BLOWER, PUMP, & PLANT CONTROL BUILDING (SEE STRUCTURAL PLANS) \ X PROP. DIGESTER JET AERATION /VACFLUSH PIPING ,I. SEE SHEET C6.2 \ k PROP. SBR JET AERATION / VACFLUSH PIPING SEE SHEET C6.2 PROP. SSMH-3 RIM: 2630.48 6" INV. IN: 2623.34 (CO-1) 8" INV. OUT: 2622.41 (SSMH-2) t tt t !J� ►t t tt t t t t t tttt tttttt �, �!' '�',a^.•.:;,w11� t t t t t t t ,. lttt !t}t{ttt ' Mi^>IIC. ttttt tj1tt 1" WATER SERVICE l i l t t t 1 t t FOR BUILDING t t t� y ill t y i i�t: y 1 1 t•1 1t t is t'1:; 1t\1 1lttt l ram` lt It‘ fit..', *4 ���'�i :..®� stir 4140",'?ce 6" TANK DRAIN & VALVE, TYP SEE SHEET C6.8 x-! X ---- k 4. Mfiews tM x_� 1001111 FM FM� \ \ \ \ \ \ 6" TANK DRAIN& VALVE, TYP SEE SHEET C6.8 6" DIP TANK DRAIN, TYP MIN. SLOPE: 1% ORP \ \ \ \ r RETAINING WALL DESIGN BY OTHERS FWOO M- FM� fiMeasso PROP. 8" FORCE MAIN SEE SHEETS C7.0 - C7.3 '\ x FM_ x _ alMifts fiMai x_ x MiriMiriallilLOMMiii 5' 0' 5' 10' 20' PROP. 8" FORCE MAIN SEE SHEETS C7.0- C7.3 0 0 U E LE d0 LU U Z \``‘ii)1 E SIG11r`''' • CORPORATE SEAL • 1;O. ''`'rrrr rr i C �`\`` aillilto ``; 9/ 19/2017 FINAL DRAWING - FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION a U <zo u- TW z_ L W w LL1 W U 5 �fW 0 W >- Z � Z r o Q OcLu D U atn;��oo 0 0OmQup t1 • (9 1_ � 000UO'cnci.. �n 4 DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 2640 2635 2630 MEMMIIIMMEMEMOIMM g.r M 1111 II MMEMMEMMI 111111118 Lc£ om�£_£MIIMMOIMMIIMM MIME IMMO alma' EX. GRADE OVER CIL 2625 2620 2615 2610 2605 0+14.95 EX. 8" DIP FORCE MAIN (APPROXIMATE LOCATION) CONTRACTOR TO VERIFY 0+00 PROP. 18 CONCRETE PIPE 0+50 PROP. GRADE OVER CIL PROP. 10" DIP 1+00 PROFILE VIEW OF PROPOSED SANITARY SEWER SCALE: 1" = 20' HORIZ. & 1" = 2' VERT. 1+50 2640 2635 2630 2625 2620 2615 2610 2605 2640 2635 2630 2625 2620 2615 2610 mmomommisimmi 7 al aliammormodur 2605 .,,i' c, Ag �G�y��. Qa11 ll PA11111111111111111IP M ....ram 1111 0+65.30111111111.11111/4/111111111111111111 EX. UG POWER (APPROXIMATE LOCATION) 1111111111111111111111 CONTRACTOR TO VERIFY , M all PROP. 18 CONCRETE PIPE j . 0 1111111111111 1111111111111111111111117111111111111111111111 0IV o W + ti QG u? f to O CV o O ob ? MR co co EX.12" DIP 1111111111111 111111 1+50 2+00 90.00° HORIZ. ELBOW SBR STA: 1+93.67 2640 0+68.41 EX. 8" DIP FORCE MAIN (APPROXIMATE LOCATION) CONTRACTOR TO VERIFY w O z 0 0 Q) 0 0+00 0+50 1+00 PROFILE VIEW OF PROPOSED 10" DIP EFFLUENT LINE FROM SBR TO FILTER BUILDING SCALE: 1" = 20' HORIZ. & 1" = 2' VERT. 2635 2630 2625 2620 2615 2610 2605 EXISTING UTILITIES NOTE: EXISTING UTILITIES AS SHOWN ARE A COMPOSITE OF SURVEY, G1S, AND AS -BUILT INFORMATION. CONTRACTOR TO FIELD VERIFY ALL INVERT ELEVATIONS AND UTILITY LOCATIONS INCLUDING VERTICAL ELEVATIONS PRIOR TO STARTING CONSTRUCTION. CONTRACTOR TO NOTIFY ENGINEER AND OWNER OF ANY DISCREPANCIES. 5' 0' 5' 10' 20' N N co !V U Z .o N M o ci C cc' ei Vr� Q) U., • CORPORATE SEAL:, 0. rrr,r,'; S AL 6988 .A� • !YGfNEF'...•.'� 1,,,�'`r C. I I t3►��``� 9/19/2017 FINAL DRAWING - FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 PROP. BLOWER, PUMP, & PLANT CONTROL BUILDING SEE SHEET C3.4 FOR ADDITIONAL INFORMATION INFLUENT FROM EX. LIFT STATION 2800' PROP. 10" AUTOMATIC VACFLUSH VALVE, TYP PROVIDED BY SBR MANUFACTURER -- x x ---- x x PROP. i0"AUTOMATIC INFLUENT VALVE PROVIDED BY SBR MANUFACTURER PROP. 8" AUTOMATIC PLUG VALVE, TYP SEE NOTE #1 PROP. 8" AUTOMATIC VACFLUSH VALVE, TYP PROVIDED BY SBR MANUFACTURER PROP. VERTICAL CLOSE COUPLED SOLIDS HANDLING PUMP (FAIRBANKS-MORSE MODEL B5443 - 8" SUCTION & 6" DISCHARGE) PROVIDED BY SBR MANUFACTURER TO BE INSTALLED BY CONTRACTOR PER PUMP MANUFACTURERS SPECIFICATIONS SEE SHEET C6.8 PROP. 8" AUTOMATIC WASTE SLUDGE VALVE PROVIDED BY SBR MANUFACTURER CAST IRON FLOOR DRAIN, TYP 75 SO IN MIN FREE AREA 15" TOP, 6" DIA OUTLET JR SMITH 2295 OR APPROVED EQUAL PIPING NOTE: 1. PIPING FROM THE SBR TO JET AERATION PUMPS SHALL BE DIP WITH FLANGED JOINTS. 2. ALL EXPOSED PIPING SHALL BE PAINTED 2 COATS OF ENAMEL PER OWNER'S COLOR SELECTION. 3. PIPING SHALL BE COLOR CODED AND LABELED PER OWNER'S SELECTION. NOTES: 1. AUTOMATIC AND MANUAL CONTROL VALVES REQUIRED FOR JET AERATION SYSTEMS TO BE PROVIDED BY MANUFACTURER. ALL VALVES LOCATED IN THE PUMP ROOM SHOWN ON THIS SHEET TO BE SUPPLIED BY THE MANUFACTURER AND INSTALLED BY THE CONTRACTOR UNLESS NOTED OTHERWISE. PROP. VERTICAL CLOSE COUPLED SOLIDS HANDLING PUMP ON 6" (T) CONC. BASE SEE SHEET C6.8 PROP ECCENTRIC EXPANDER DIGESTER JET AERATION: 6" X 8" PROP. VERTICAL CLOSE COUPLED SOLIDS HANDLING PUMP (FAIRBANKS-MORSE MODEL 65444S -10" SUCTION & 8" DISCHARGE) PROVIDED BY SBR MANUFACTURER TO BE INSTALLED BY CONTRACTOR PER PUMP MANUFACTURERS SPECIFICATIONS SEE SHEET C6.8 PROP. CO-1 RIM: 2631.02 6" INV. OUT: 2624.00 (SS M H-3) PROP. 10" AUTOMATIC VACFLUSH VALVE, TYP PROVIDED BY SBR MANUFACTURER 8" X 10" EXPANDER FLEXIBLE EXPANSION JOINT, TYP PROP. 1" WATER LINE PROP. GV TIE TO EX. WATER LINE PROP. 10" AUTOMATIC INFLUENT VALVE PROVIDED BY SBR MANUFACTURER PROP 8" FM FROM LIFT STATION SEE SHEETS C7.0 - C7.3 PROP. 8" AUTOMATIC VA VALVE, TYP PROVIDED BY SBR MAN RER (1) TURNED (1) TURNED TIC VACFLUSH VALVE, TYP PROVIDED MANUFACTURER PROP. 8" AUTOMATIC VACFLUSH VALVE, TYP PROVIDED BY SBR MANUFACTURER I WAS PIPING (SEE ABOVE) TYPICAL SBR VACFLUSH CROSSOVER PIPING SCALE: NTS Alm* • 10" DIP 8" DIP PROP. 8" AUTOMATIC VACFLUSH VALVE, TYP PROVIDED BY SBR MANUFACTURER . . 0" DIP 10" DIP 8" DIP 6" DIP PROP. CONNECTION FOR SLUDGE REMOVAL PROP. 10" AUTOMATIC INFLUENT VALVE PROVIDED BY SBR MANUFACTURER FLEXIBLE EXPANSION JOINT, TYP PROP. 45° BEND, TYP • 10" DIP PROP. BOLLARD SEE SITE PLAN & DETAILS SHEET C3.5 PROP. FREEZE / PROOF HYDRANT ATER SERVICE FOR BUILDING PROP. WATER SERVICE FOR SBR PROP. SSMH-3 RIM: 2630.4a 8" INV. OUT: 2622.41 (SSMH-2) PROP 8" SS SEE SHEET C6.0 & C6.1 SEE BELOW GRADE WALL PENETRATION DETAIL SHEET C6.9 FLEXIBLE EXPANSION JOINT, TYP • • • • • PROP. RETAINING WALL SEE SITE, STRUCTURAL, & GRADING PLANS FOR ADDITIONAL INFORMATION 8" DIGESTER SUCTION (UNDER SBR JET HEADER) 10" SBR JET E 8" DIGESTER WAS • 8" DIGESTER JET HEADER (UNDER SBR JET HEADER) 10" SBR JET HEADER (OVER DIGESTER JET HEADER) 10" ID/SC MANIFOLD SBR 1 IFOLD SBR2 DIGESTER EQUIPMENT NOTES: .1. EQUIPMENT TO BE SUPPLIED BY THE OWNER OR SBR MANUFACTURER SHALL BE INSTALLED BY THE CONTRACTOR ACCORDING TO MANUFACTURER'S SPECIFICATIONS. 2. THE OWNER SHALL PROVIDE SHOP DRAWINGS OF THE PROPOSED EQUIPMENT TO 'THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 3. CONTRACTOR SHALL CONFIRM ALL DIMENSIONS ON 'THE PROVIDED SHOP DRAWINGS ARE CONSISTENT WITH THOSE SHOWN IN THESE PLANS PRIOR TO THE START OF CONSTRUCTION. 4. DISCREPANCIES SHALL BE REPORTED TO THE OWNER AND THE ENGINEER IMMEDIATELY. TANK WALL rAA 3.33' 0.49' HYDROSTATIC BUL 2.50' 1.75' 2.50' 4.76' JET AERATION CONNECTIONS 2.33' SBR 2 614 SBR FLOOR EL = 0.00 C6.2 PLAN/ELEVATION VERTICAL CLOSE COUPLED SOLIDS PROVIDED BY SBR MANUFACTURER TO BE INSTALLED BY CONTRACTOR PER PUMP MANUFACTURER'S SPECIFICATIONS PROP. 90° BEND INFLUENT FROM EX. LIFT STATION frBB 00 NOTE: 1. DRAWING IS NOT TO SCALE 2. VALVES NOT SHOWN FOR CLARITY 3. DIGESTER VACFLUSH PIPING HAS SIMILAR ELEVATION. SEE ABOVE FOR PIPE SIZES PROP ECCENTRIC EXPANDER SEE ABOVE PLAN FOR SIZE PROP. 10" X 8" CROSS 6" (T) CONCRETE EQUIPMENT BASE 4 SEE UTILITY PLAN, STRUCTURAL PLAN, & MANUFACTURER'S SPECIFICATIONS TYPICAL SBR VACFLUSH PIPING NTS PROP. 90° BEND PROP. 10" X 10" X 8" TEE SECTION NTS co at Xi V in cel en CS el go in go u E 444 441 CORPORATE .. .......... 9/19/2017 FINAL DRAWING - FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION V) < Z LLI Lil Z (= Z < 0 ci7C? co 0 co L: ari' -- :."6-L r )614u - '1213- ›'za 35! 'a 3 8A:c ' El "tr 1 1 bil! g % C ; f 1 ClOWOCUICYLIV)61:1—Ci Eg U :4 DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 f PROP. BACK-UP GENERATOR REFER TO ELECTRICAL PLANS FOR DETAILS fl WATER LINE STUB FILTER / UV BUILDING fl 56.00' N 0+00.00 90° VERT. BEND 1%- 3 b t>• CLOTH MEDIA FILTER, PROVIDED BY OWNER 5.93' I._. iMi • U J CAST IRON FLOOR DRAIN, TYP 75 SQ IN MIN FREE AREA 15" TOP, 6" DIA OUTLET JR SMITH 2295 OR APPROVED EQUAL 10" DIP INV. 2616.58 0 A NMI .,-.. 4... L. 0+19.03 90° HORIZ. BEND 0+33.71 45° HORIZ. BEND z m 0 z m Uo O J 0 0+52.50 45° HORIZ. BEND SS JOSS 14.7 LF OF 10" DIP 'FOSS PROP. SSMH-4 RIM: 2621.94 12" INV. IN: 2606.80 (EX SSMH-2) 10" INV. IN: 2615.84 (10" BEND) 12" INV. OUT: 2606.80 (SSMH-1) 5y SS SS SS SS SS SS SS EX. 35.59 LF OF 12" DIP @ 2.26% i PROP. 10" 90° BEND TO FILTER OVERFLOW OUTLET PROP. 10" 90° BEND TO FILTER INLET PROP. 10" X 6" REDUCER PROP. 10" PLUG VALVE (BY CONTRACTOR) PROP. 10" 90° BEND ±7.5' (AA PROP. 10" TEE PROP. 10" 90° BEND PROP. 10" DIP OVERFLOW PIPING PROP. 6" DIP 24" MIN METER TO EXPANDER 36" MIN REDUCER TO METER PROP. 6" ELECTRO MAGNETIC FLOW METER SIEMENS MAG 5100W 3 (SUPPLIED BY SBR MANUFACTURER - INSTALLED BY CONTRACTOR) 6" BACKWASH BUTTERFLY VALVE SUPPLIED BY FILTER MANUFACTURER 0 v, N DRAI DRAI j---- SEE INSET 'DRAIN-- DRAT 10 73' SEE SHEET C6.10 FOR FILTER TO UV PIPE ELEV. 7.63' 1 1 PROP CLOTH MEDIA FILTER, 1 PROVIDED BY OWNER _. 6" DIP FLOOR DRAIN PIPING SEE BUILDING PLANS FOR INTERIOR DRAIN LOCATIONS AND DETAILS PROP LAB BENCH DESIGN BY OTHERS SEE BUILDING PLANS FOR ADDITIONAL INFORMATION PROP UV DISINFECTION, PROVIDED BY OWNER PROP FLOW MONITORING WEIR 304 SS BOX MOUNTED IN SLAB, PROVIDED BY OWNER SEE SHEET C6.11 SEE SHEET C6.10 FOR FILTER TO UV PIPE ELEV. PROP UV DISINFECTION, PROVIDED BY OWNER 8.98' SEE BELOW GRADE WALL PENETRATION DETAIL SHEET C6.9 l PROP. 10" DIP SEE SHEET C6.0 0S 1OSS TOSS PROP. EBAA FLEX -TEND® FLEXIBLE EXPANSION JOINT, TYP 36.00' 0SS PROP. 37.15 LF OF 10" PROP. FILTER & UV DISINFECTION BUILDING SEE SHEET (SEE STRUCTURAL PLANS) 0 0 co SS CLEANOUT, TYP SEE BUILDING PLANS FOR CONTINUATION SS SS SS SS SS SS SS SS SS EX. 41.77 LF OF 12" DIP @ 2.26% PROP. 10" PLUG VALVE (SUPPLIED BY CONTRACTOR) PROP. 10" PLUG VALVE (SUPPLIED BY CONTRACTOR) PROP. 10" 90° BEND TO FILTER #2 OVERFLOW PROP. 10" 90° BEND TO FILTER #2 INLET PROP. AUTOMATIC PLUG VALVE FOR FLOW CONTROL ABOVE BEND (SUPPLIED BY SBR MANUFACTURER) PROP. 90 ° VERTICAL BASE BEND PROP. 6" X 10" EXPANDER PROP. 6" TEE WITH BLIND FLANGE ONE END PROP. 10" X 10" X 6" TEE PROP. 10" DIP OVERFLOW PIPING CLOTH MEDIA FILTER INFLUENT PIPING FLOOR C6.3 ,A SECTION NTS SS SS (BB EX. 12" DIP SS, TYP EX. EX SSMH-2 PROP. 10" TEE WITH BLIND FLANGE ONE END PROP. 6" TEE WITH BLIND FLANGE ONE END f PROP. 10" 90° BEND 10" X 10" X 6" TEE BELOW 6" BACKWASH BUTTERFLY VALVE SUPPLIED BY FILTER MANUFACTURER PROP. 10" 90° BEND BACKWASH MANIFOLD 2.5' 0' 2.5' 5' 10' 0 6.0 FOR CONTINUATION W W w CLOTH MEDIA FILTER, PROVIDED BY OWNER PROP. 8" 90° HORIZONTAL BEND PROP. 10" X 8" REDUCER PROP. 90 ° VERTICAL BEND PROP. AUTOMATIC PLUG VALVE FOR FLOW CONTROL ABOVE BEND (SUPPLIED BY SBR MANUFACTURER) PROP. 6" X 10" EXPANDER BELOW VALVE PROP. 6" DIP 24" MIN METER TO EXPANDER PROP. 6" ELECTRO MAGNETIC FLOW METER SIEMENS MAG 5100W (SUPPLIED BY SBR MANUFACTURER - INSTALLED BY CONTRACTOR) PROP. 6" DIP 36" MIN REDUCER TO METER PROP. 10" 90° BEND PROP. 10" 90° BEND PROP. 10" DIP OVERFLOW PIPE PROP. 10" X 10" X 6" TEE PROP. 6" TEE WITH BLIND FLANGE ONE END FILTER OVERFLOW & BACKWASH PIPING PROP. 10" 90° BEND FLOOR C6.3 G PLAN / SECTION NTS PROP COMPRESSOR, TYP SUPPLIED BY OWNER NOT TO SCALE PROP CONTROL PANEL,TfP NOT TO SCALE PROP 8" AUTOMATIC PLUG VALVE SUPPLIED BY CONTRACTOR PROP 8" TEE PROP (2) - 8" 90° VERTICAL BENDS 0 I O.j Il• PROP. 10" PLUG VALVE (SUPPLIED BY CONTRACTOR) PROP. 10" TEE PROP. 10" PLUG VALVE (SUPPLIED BY CONTRACTOR) EQ, 10" DIP INV. 2616.58 PROP (2) - 8" 90° VERTICAL BENDS PROP BACKWASH / OVERFLOW PIPING A PROP. 10"X 8" REDUCER I I PROP. 6" DIP PROP. 10" X 6" REDUCER E s I 1 i PROP. 10" PLUG VALVE (BY CONTRACTOR) I I 1 1 3 t PROP. 10" 90° BEND 1 I PROP. 10" 90° BEND (TURNED UP) 1 1 • • PROP 8" X 12" EXPANDER PROP 8" TEE PROP. UV DISINFECTION PROVIDED BY OWNER PROP AUTOMATIC 8" PLUG VALVE SUPPLIED BY CONTRACTOR PROP. UV DISINFECTION PROVIDED BY OWNER PROP 8" X 12" EXPANDER PROP CLOTH MEDIA FILTER PROVIDED BY OWNER '.'" I INSET SCALE: 1" = 2' PIPING NOTE: 1. PIPING FROM THE FILTER TO WEIR BOX SHALL BE DIP WITH FLANGED JOINTS. 2. ALL EXPOSED PIPING SHALL BE PAINTED 2 COATS OF ENAMEL PER OWNER'S COLOR SELECTION. 3. PIPING SHALL BE COLOR CODED AND LABELED PER OWNER'S SELECTION. EQUIPMENT NOTES: 1. EQUIPMENT TO BE SUPPLIED BY THE OWNER OR SBR MANUFACTURER SHALL BE INSTALLED BY THE CONTRACTOR ACCORDING TO MANUFACTURER'S SPECIFICATIONS. 2. THE OWNER SHALL PROVIDE SHOP DRAWINGS OF THE PROPOSED EQUIPMENT TO THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 3. CONTRACTOR SHALL CONFIRM ALL DIMENSIONS ON THE PROVIDED SHOP DRAWINGS ARE CONSISTENT WITH THOSE SHOWN IN THESE PLANS PRIOR TO THE START OF CONSTRUCTION. 4. DISCREPANCIES SHALL BE REPORTED TO THE OWNER AND THE ENGINEER IMMEDIATELY. 5. THE UV SYSTEM SHALL INCLUDE CONTROL SYSTEMS TO AUTOMATICALLY SWITCH FLOW BETWEEN UNITS IN THE EVENT OF MALFUNCTION OR LOW PERFORMANCE. SEE ELECTRICAL PLANS FOR ADDITIONAL INFORMATION. SIG!'''%, CORPORATE SEAL : ...... .�` rttr1111ti11 Gflk1;;� 4:4„/11fIi11111ti��,` 9/19/2017 FINAL DRAWING - FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION • DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 PROP. 6" 90° LR BEND, TYP AUTOMATIC BUTTERFLY VALVE, TYP SUPPLIED BY SBR MANUFACTURER MANUAL BUTTERFLY VALVE, TYP SUPPLIED BY SBR MANUFACTURER MANUAL BUTTERFLY VALVE, TYP SUPPLIED BY SBR MANUFACTURER PROP. 8" DIP MANUAL BUTTERFLY VALVE, TYP SUPPLIED BY SBR MANUFACTURER PROP. 6" DIP MANUAL BUTTERFLY VALVE, TYP SUPPLIED BY CONTRACTOR SEE BELOW GRADE WALL fix. ` '+� • ` • - - PROP. 4" 45° BEND, TYP �� ►.► >• �\MIiI ITI� E a. r m1 'i,ip *P11110111*4 ■iiimfj 25S BACK-UP 499 SCFM 25S SBR #2 499 SCFM 25S SBR #1 499 SCFM PROP. 6" FLEXIBLE CONNECTION TYPICAL (FIVE LOCATIONS) SEE DETAIL SHEET C6.9 goso®®I®®®®1®®t®® ENE ®®®®®®®®® MANUAL BUTTERFLY VALVE, TYP ,c\ \\ SUPPLIED BY SBR MANUFACTURER \\ \\\ \ \ `� �\ • MANUAL BUTTERFLY VALVE, TYP \ SUPPLIED BY SBR MANUFACTURER \ \\ • SEE SHEET C6.5 ® NOTES: PROP. BLOWER PUMP, & PLANT CONTROL BUILDING (SEE STRUCTURAL PLANS) Pc- 0 1. AUTOMATIC AND MANUAL CONTROL VALVES REQUIRED FOR AERATION SYSTEM TO BE PROVIDED BY MANUFACTURER. ALL VALVES LOCATED IN THE BLOWER ROOM SHOWN ON THIS SHEET TO BE SUPPLIED BY THE MANUFACTURER AND INSTALLED BY THE CONTRACTOR UNLESS NOTED OTHERWISE. SOLBERG BLOWER INLET SILENCER, TYP BEE CI tEcr CG.9 NOTES: 1. INLET MANUAL BUTTERFLY VALVES SUPPLIED BY CONTRACTOR. ...-.- 2. SEE DETAIL SHEET C6.9 FOR ADDITIONAL INFORMATION. 3. INLET PIPING IDENTICAL FOR ALL 25S BLOWERS 4. SEE SHEET C6.9 FOR TYPICAL FLEXIBLE INLET CONNECTION TO BLOWER 5. SEE SHEET C6.5 FOR INLET PIPING CROSS SECTIONS 25S / BACK-UP --� 499 SCFM PIPE STANCHION (BELOW) FIELD CUT AND WELDED TO FIT SEE SHEET C6.9 25S SBR #2 499 SCFM SEE WALL PENETRATION DETAIL SHEET C6.9 25S SBR #1 499 SCFM 5" X 6" EXPANDER, TYP 6" MANUAL BUTTERFLY VALVE, TYP (2)-6" 90° VERT. BEND, TYP SEE SHEET C6.5 & SHEET C6.9 SOLBERG BLOWER INLET SILENCER, TYP SEE SHEET C6.9 SOLBERG BLOWER INLET SILENCER, TYP CCC CI fECT CC.0 (2)-4" 90° VERT. BEND, TYP I SEE SHEET C6.5 & SHEET C6.9 4" MANUAL BU'°f IRFLY VALVE, TYP 3" X 4" EXPANDER,`1 R • (2)-4" 90° VERT. BEND, TYP SEE SHEET C6.5 & SHEET C6.9 4" MANUAL BUTTERFLY VALUE, TYP 3" X 4" EXPANDER, TYP BLOWER INLET PIPING SCALE: 1" = 5' W W • • \ • • • • • \ • 4%4 6" AIR CONNECTIONS aistal emu Ir 111111 .1 1 1 PROP.6" DIP PIPE, TYP 3' MIN COVER SBR 1 PROP.4" DIP PIPE, TYP 3' MIN. COVER • • PROP. RETAINING WALL SEE SITE, STRUCTURAL, & GRADING PLANS FOR ADDITIONAL INFORMATION PROP. 90° VERTICAL BEND, TYP TRANSITION TO WELDED SCHEDULE -. --- 10 STAINLESS STEEL PROP. 45° HORIZ. BEND, TYP DIGESTER STAINLESS STEEL DIFFUSER, TYP SEE SBR PLANS FOR ADDITIONAL INFORMATION SBR2 PROP. 2" - 22.5° HORIZ. BEND, TYP 4,"\ STAINLESS STEEL DIFFUSER, TYP SEE SBR PLANS FOR ADDITIONAL INFORMATION PROP. 2" - 22.5° HORIZ. BEND, TYP PROP. 4" X 2" REDUCER, TYP PROP. 4" X 4" X 4" TEE PROP. 3" X 2" REDUCER, TYP POST EQ. 10' 1 PIPING NOTE: PIPING FROM THE BLOWERS TO THE SBR SHALL BE DUCTILE IRON. TRANSITION TO WELDED STAINLESS STEEL FOR HORIZONTAL PIPING ABOVE SBR TANKSS co U Z .n v' O N CO M Co �Ego 12) o W E Z 3 tOA ab \\,`9 ESitip y►!! ti4/1. • %•-, • CORPORME • E7-‘1i;:;:11). SEAL /J 1j1!!t!illlti�\, FINAL DRAWING - FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION h z 0 z LU CZ Li3 w 0 J LU d_ cL REVISIONS: CO U 07 re)NV)cO 1- QQ>-m©II 4 ♦ Ll1(i—mQ� U01.w.J W 000Udv,o.. V='1 DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 PROP. 6" 90° LR BEND, TYP PROP. 8" X 6" REDUCER, TYP PROP. 8" 45°BEND, TYP (BELOW) PROP. 8"X8"X 6" TEE, TYP (BELOW) _-C3 3.00' 6" DIP PROP. 6" 90° VERT. BEND THROUGH FLOOR PROP. 8" 45° BEND, TYP AUTOMATIC BUTTERFLY VALVE, TYP SUPPLIED BY SBR MANUFACTURER 3.00' PROP. 6" 45° BEND, TYP PROP. 8" X 6" 45° LATERAL, TYP 25S BACK-UP 499 SCFM MANUAL BUTTERFLY VALVE, TYP SUPPLIED BY SBR MANUFACTURER PROP. 8" X 8" X 8" TEE WITH 8" 90° VERTICAL BEND ABOVE MANUAL BUTTERFLY VALVE, TYP SUPPLIED BY SBR MANUFACTURER PROP. 6" FLEXIBLE CONNECTION SEE DETAIL SHEET 2.50' 5.42' MANUAL BUTTERFLY VALVE, TYP SUPPLIED BY CONTRACTOR PROP. 8" X 6" REDUCER, TYP PROP. 8" X 6" 45° LATERAL, TYP 6.14' PROP. 6" 45° BEND PROP. 6" 90° LR BEND, TYP 4"DIP 6" DIP 6" DIP PROP. 6" 45 BEND PROP. 6" 90° VERT. BEND THROUGH FLOOR Y PROP. 6" 90° VERT. BEND **MI IMO �A"X6"TEEBELOW 6"X ± 3' 2.50' MANUAL 4" BUTTERFLY VALVE, TYP SUPPLIED BY SBR MANUFACTURER PIPING NOTE: PIPING FROM THE BLOWERS TO THE SBR SHALL BE DUCTILE IRON. NOTES: 1. AUTOMATIC AND MANUAL CONTROL VALVES REQUIRED FOR AERATION SYSTEMS TO BE PROVIDED BY MANUFACTURER. ALL VALVES LOCATED IN THE PUMP ROOM SHOWN ON THIS SHEET TO BE SUPPLIED BY THE MANUFACTURER AND INSTALLED BY THE CONTRACTOR UNLESS NOTED OTHERWISE. 2, BLOWER INLET PIPING NOT SHOWN FOR CLARITY. SEE DETAIL SHEET FOR TYPICAL SECTION AND ADDITIONAL INFORMATION AERATION PIPING DETAIL SCALE: 1" = 2' ADDITIONAL NOTES: 1. CONTRACTOR SHALL VERIFY ALL BLOWER DIMENSIONS PRIOR TO INSTALLATION OF ANY PIPING 2. ALL CONNECTIONS TO BE PER MANUFACTURER'S SPECIFICATIONS PROP. 6" x 4" 90° VERT. BEND 4"X4"X4"TEE BELOW PROP. 3" x 6" 90° LR BEND, TYP L PROP. 3" FLEXIBLE CONNECTION SEE DETAIL SHEET PROP. 3" x 4" 90° LR BEND, TYP PROP. 3" FLEXIBLE CONNECTION SEE DETAIL SHEET 'v \ PROP. 6" 90° VERT. BEND THROUGH FLOOR PROP. 8" VERT. 45° BEND MANUAL BUTTERFLY VALVE, TYP SUPPLIED BY CONTRACTOR PROP. 8" X 6" 45° LATERAL, TYP /4:7,4 ll \ll `` \I l` I/ ///\/ % � // \//k/i/&T/Y \/////// /t/L, I\\/ % /_\/,�l/---- l_���Ii��/,��,� �,_I_ SECTION AA SCALE: 1" = 2' BLOWER INLET PIPING, TYP SEE SHEETS C6.4 & C6.9 PROP. 6" X 8" 90° LR EXPANDING BEND BLOWER INLET PIPING, TYP SEE SHEETS C6.4 & C6.9 PROP. 8" X 8" X 6" TEE, TYP PROP. 8" 90° LR VERT. BEND, TYP 8" DIP i PROP. 8" X 6" 45° LATERAL, TYP PROP. 6" x 4" 90° VERT. REDUCING BEND 4" X 4" X 4" TEE BELOW PROP. 6" 90° VERT. BEND 8" X 6" X 6" TEE BELOW 8" DIP PROP. 8" X 8" X 6" TEE, TYP 8"DIP 6"DIP 6" DIP AUTOMATIC BUTTERFLY VALVE, TYP SUPPLIED BY SBR MANUFACTURER PROP. 8" 90° LR VERT. BEND, TYP /. / •9./ l�/r//l�/l /l i4//////\////�,/J //l/i///r///l /\//l// l///I//_ - //,`\y`,. .=\// /\/ / \//\ \/\/ \/\\/// /` /�� /` SUPPLIED BY SB\MANUFACTURER ��\ / /�\l�-���I,-,//\l :_//_=/\=/ \/`=\ `�I\/��//�� 4/1:- MANUAL B�UTTERFLY VALVE, YP `_/_llI/ \/\ 11//\,,\�/,/\_/ _-,\_\�/,'�/_% /\,/ . _ •`/- �\-`�///`/ _�\/;l`/\l/ ////,/,,,,///,,\/ \/ll/ll/Il/\/ mi/////.///--/--M/,/V-// a � // ///ll ///l_/ `l// ,// ll� r I/l` l/= '-�11%1/\llII/\_\ a.• • --�/%// =\_�/_���//I/`�/ _�—_/!�,/_\`/ I\\ lIl`l l,`/`lll�lll��I/\o/�Il`ll/.�/_ /`\6" DIP 11 /// SECTION BB SCALE: 1" = 2' l PIPE STANCHION FIELD CUT AND WELDED TO FIT SEE SHEET C6.9 PROP. 6" 90° VERT. BEND 6" X 6" X 6" TEE BELOW 6" DIP SOLBERG BLOWER INLET SILENCER, TYP SEE SHEET C6.9 SEE WALL PENETRATION DETAIL SHEET C6.9 6" 90° VERT. BEND, TYP 4//'// // 777- 4" DIP // • d ///•--„ PROP. 6" x 4" 90° VERT. REDUCING BEND 4" X 4" X 4' TEE BELOW 6" 90° VERT. BEND, TYP SEE SHEET C6.9 4" MANUAL BUTTERFLY VALVE (NOT SHOWN), TYP 3" X 4" EXPANDER, TYP 6" DIP 4 P 4 • 4 t• • ti// / I\/ mil/ / \lam / 1\mil% /l\ Il/\ l�/f_71/I\\ -,l\ lI\ 77/ 1. I i l 1._,/ ,///-//1 6" 90° VERT. BEND, TYP 6" 90° VERT. BEND, TYP SEE SHEET C6.9 4" MANUAL BUTTERFLY VALVE (NOT SHOWN), TYP 3" X 4" EXPANDER, TYP SECTION CC SCALE: 1" = 2' • J MinilliM111111171111111.111111111 ' 0' I' 2' 4" F ++++ti►1Iirrrrrrr 9SiN • COTE :moo: •=,4� •O • C. 9/19/2017 FINAL DRAWING - FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION AIR PIPING PLAN - SECTIONS Z 0 ul w DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 x --- x X ---- X x --- X X ..�.-x X �_X—^-X.�-X x -- x -- x ---' x ___- x ...-- x ---- x ---- x ____ x ---' x -- x ----`� x --- x _.._ x -- X _ _-_ X k \ 1---' �-- 1.48' 1.31' EQUIPMENT NOTES: 1. EQUIPMENT TO BE SUPPLIED BY THE OWNER OR SBR MANUFACTURER SHALL BE INSTALLED BY THE CONTRACTOR ACCORDING TO MANUFACTURER'S SPECIFICATIONS. 2. THE OWNER SHALL PROVIDE SHOP DRAWINGS OF THE PROPOSED EQUIPMENT TO THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 3. CONTRACTOR SHALL CONFIRM THAT ALL DIMENSIONS ON THE PROVIDED SHOP DRAWINGS ARE CONSISTENT WITH THOSE SHOWN IN THESE PLANS PRIOR TO THE START OF CONSTRUCTION. 4. DISCREPANCIES SHALL BE REPORTED TO THE OWNER AND THE ENGINEER IMMEDIATELY. BUILDING NOTES: 1. SEE ELECTRICAL, STRUCTURAL, AND BUILDING PLANS FOR ADDITIONAL INFORMATION. 2. SEE UTILITY SHEETS C6.2 & C6.3 FOR ADDITIONAL PIPING LAYOUT INFORMATION 3. SEE SHEETS C6.4 - C6.5 FOR BLOWER BUILDING AERATION PIPING INFORMATION 4. SEE SHEETS C3.0 - C3.2, & C3.5 FOR SITE LAYOUT INFORMATION 5. BUILDING FLOOR DRAINS TO BE TRAPPED AND VENTED PER ALL APPLICABLE CODES. UTILITY NOTES: 1. SEE UTILITY AND PIPING PLANS FOR PIPE SIZES AN ADDITIONAL LAYOUT INFORMATION 2. SITE, BUILDING, AND UTILITY CONTRACTORS SHALL COORDINATE CONSTRUCTION ACTIVITIES TO MINIMIZE DELAYS 3. CONTRACTOR SHALL VERIFY EQUIPMENT SELECTION AND PIPING LAYOUT PRIOR TO BUILDING SLAB CONSTRUCTION. 4. ANY DISCREPANCIES SHALL BE BROUGHT OT THE ATTENTION OF THE OWNER AND ENGINEER IMMEDIATELY. N U Z.o ti N M O fV co ed E w N L IN u c `cN �3 M � E E CZ bb ZS • (� Z VESIG • • 4' CORPORATE tritisissittO FINAL DRAWING - FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION CL Z <zo � W Z W w LL' U eL cc LLI W W �L Z 4 U LL U Z 0 co 0 79" M�M N4 U Sri ,r,cn03p '- �j,:L >-`nV)n- %OD 3©m©p 11 * •• a.WZu.► •• " W Z ec>--G w(9.() nnonuo�v)a DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 SELECT MATERIAL COMPACTED IN 6" LIFTS SELECT MATERIAL COMPACTED IN 3" LIFTS SHEETED TRENCH fr,‘ 24" MAX. :.i 12" MIN. II 11 IE 11Jt UNDISTURBED EARTH OR ROCK SELECT MATERIAL COMPACTED IN 6" LIFTS SELECT MATERIAL COMPACTED IN 3" LIFTS .II Flu UNDISTURBED EARTH OR ROCK OPEN TRENCH 12 GAGE COPP WIRE SECURE NOTE: BELL HOLES NOT SHOWN STANDARD EXCAVATION SHEETED TRENCH 24" MAX. t— I11— OPEC TRENCH R NOTES: 1. CROSSING A WATER MAIN OVER A SEWER; WHENEVER IT IS NECESSARY FOR A WATER MAIN TO CROSS OVER A SEWER, THE WATER MAIN SHALL BE LAID AT SUCH AN ELEVATION THAT THE BOTTOM OF THE WATER MAIN IS AT LEAST 18" ABOVE THE TOP OF THE SEWER, UNLESS LOCAL CONDITIONS OR BARRIERS 12 GAGE COPPER TRACER PREVENT AN 18 INCH VERTICAL SEPARATION; IN WIRE SECURED TO PIPE WHICH CASE BOTH THE WATER MAIN AND SEWER SHALL BE CONSTRUCTED OF FERROUS MATERIALS AND WITH JOINTS THAT ARE EQUIVALENT TO WATER MAIN STANDARDS FOR A DISTANCE OF 10 FEET ON EACH SIDE OF THE POINT OF CROSSING. 12" MAX NOTE: BELL HOLES NOT SHOWN STANDARD EXCAVATION 2. CROSSING A WATER MAIN UNDER A SEWER; WHENEVER IT IS NECESSARY FOR A WATER MAIN TO CROSS UNDER A SEWER, BOTH THE WATER MAIN AND THE SEWER SHALL BE CONSTRUCTED OF FERROUS MATERIALS AND WITH JOINTS EQUIVALENT TO WATER MAIN STANDARDS FOR A DISTANCE OF 10 FEET ON EACH SIDE OF THE POINT OF CROSSING. A SECTION OF WATER MAIN PIPE SHALL BE CENTERED AT THE POINT OF CROSSING. NOTE: MINIMUM 30" COVER IN PIEDMONT AND COASTAL AREAS MINIMUM 40" COVER IN MOUNTAIN AREA D.I.P. TO BE USED IF LESS THAN MINIMUM COVER 12/07 UTILITIES, INC. LOGO ADDED DATE REVISION SAO BY FILE NO. WATER & SEWER DETAILS SCALE: N.T.S. TYPICAL TRENCHING DATE: AUG. 2003 5701 Westpark Dr., Suite 101 STANDARD P.O. Box 240908 DETAIL NUMBER Utilities, Inc Charlotte, N.C. 28224--0908 and NC/TN Affiliates (704) 525-7990 W-10 FINISHED GRADE 3' MINIMUM COVER NO. B WORD "WATER' CAST IN TOP I It= E' STD. BROOKS PRODUCTS CONCRETE COLLAR FOR VALVE BOXES TRACER WIRE "LOOPED" UP INSIDE VALVE BOX FOR LOCATING WATER MAIN ADJUSTIBLE CAST IRON VALVE BOX 2" SQUARE OPERATING NUT CONCRETE OR WOOD BLOCKING (OR APPROVED VALVE BOX) COMPACTED BACKFILL WATER MAIN ti A— TRACER WIRE (#12 GA. COPPER) ATTACH TO WATER MAIN `'''::' .-.'.: CONCRETE SUPPORT PAD • : • ' ' • • .• (REQUIRED ON GATE VALVES _ . '`: 10" OR LARGER ONLY) NOTES: 1. GATE VALVE SHALL BE AWWA APPROVED. 2. GATE VALVE SHALL BE LEFT HAND OPEN. (C.C.W.) 3. GATE VALVE TO HAVE 2" SQUARE OPERATING NUT. 12/07 UTILITIES, INC. LOGO ADDED DATE REVISION SAO BY WATER DETAILS TYPICAL VERTICAL GATE VALVE INSTALLATION FILE NO. SCALE: N.T.S. DATE: AUG. 2003 5701 westpark Dr., Suite 101 DETAIL STANDARDNUMBER Utilities Inc: P.D. Box 240908 - .- Charlotte. N.C. 28224-0908 and N1CITN Aff:Eiata� (704) 525-7990 W-5 PLAN UNDISTURBED EARTH CONCRETE THRUST BLOCK CONCRETE THRUST BLOCK UNDISTURBED EARTH ELEVATION NOTE: CARE SHALL BE TAKEN WHEN PLACING THRUST BLOCKS TO KEEP THE FITTING BOLTS FREE OF CONCRETE. SIZE 11 1 /4' BEND 22 1/2' BEND 45' BEND 90' BEND TEE PLUG 4 12 12 12 16 16 14 6 12 12 12 16 16 14 8 12 12 16 22 22 18 10 12 14 20 28 28 22 12 12 18 24 32 32 28 14 14 20 28 38 38 32 16 16 22 32 42 42 36 18 18 26 36 48 48 40 20 20 28 40 52 52 44 24 24 34 46 64 64 54 30 30 42 58 78 78 66 36 36 50 70 94 94 80 42 40 58 80 108 108 92 48 46 66 90 124 124 104 THRUST BLOCKS - DIMENSION "A" NO. 12/07 DAT VTILUT1ES, INC. LOGO ADDED REVISION SAO BY WATER DETAILS FILE NO. SCALE: N.T.S. TYPICAL THRUST BLOCK FOR BENDS DATE: AUG. 2003 5701 Westpark Dr., Suite 101 UtilitjE$_ IV)G P.O. Box 240908 DETAIL NUMBER Charlotte, N.C. 28224-0908 ond NC/TN Afffintrt• (704) 525-7990 STANDARD W-6 LOCKING HOLE FREEZELESS YARD HYDRANT ASSEMBLY IOWA'il MODEL Y34 OR Y1 2'x2'x4" THICK CONC. SPLASH PAD 11F1II=L . -1II�-1TI.:-m 8. WASHED STONE FOR DRAINAGE 9', 27-1/2" FINISHED GRADE III I1111117 l f 3III 1 I —III —I I I —III —III —III —I I IW 111--7 111I. III'"""' 3'-0" MIN. BURY NOTE: FREEZELESS HYDRANT TO BE IOWA®MODEL Y34 OR Y1 OR APPROVED EQUAL 1 I 12/07 UTILITIES, INC. LOGO ADDED NO. DATE REVISION SAO BY WATER DETAILS FREEZELESS YARD HYDRANT FILE NO. SCALE: N.T.S. DATE: AUG. 2003 STANDARD 5701 westpork Dr., Utilities; In _ P.O. Box 240908 Suite 101 DETAIL NUMBER ' Charlotte, N.C. 28224-0908 and NC/TN Vigo (704) 525-7990 W-12 UNDISTURBED EARTH CONCRETE THRUST BLOCK PLAN CONCRETE THRUST BLOCK UNDISTURBED EARTH ELEVATION NOTE: CARE SHALL BE TAKEN WHEN PLACING THRUST BLOCKS TO KEEP THE FITTING BOLTS FREE OF CONCRETE. SIZE 11 1/4' BEND 22 1/2' BEND 45' BEND 90' BEND TEE PLUG 4 12 12 12 16 16 14 6 12 12 12 16 16 14 8 12 12 16 22 22 18 10 12 14 20 28 28 22 12 12 18 24 32 32 28 14 14 20 28 38 38 32 16 16 22 32 42 42 36 18 18 26 36 48 48 40 20 20 28 40 52 52 44 24 24 34 46 64 64 54 30 30 42 58 78 78 66 36 36 50 70 94 94 80 42 40 58 80 108 108 92 48 46 66 90 124 124 104 THRUST BLOCKS - DIMENSION "A" NO. 12/07 UTILITIES, INC, LOGO ADDED DATE REVISION SAO BY WATER DETAILS TYPICAL THRUST BLOCK FOR TEES FILE NO. SCALE: N.T.S. DATE: AUG. 2003 5701 Westpark Dr„ Suite 10i STANDARD f �/,�t )ETAIL NUMBER Utii1>I:leSt iliG P.O. Box 24.C. 7E R y (704)Charl52 N.C. 28224-0908 and NC/TN Affiliates (704) 525-799D W-7 A + PIPE ©IA. III CONCRETE THRUST BLOCK 5/8" 0 THREADED ROD (GALVANIZED OR BITUMINOUS COATED) e II.: A.'....:e.. .• C 4"U LARGER IL- •A � A �4.A —1I I} 111 1.•A fI 1 UNDISTURBED EARTH 2" PLUG TO STANDARD BLOW —OFF' NOTE: CARE SHALL BE TAKEN WHEN PLACING THRUST BLOCKS TO KEEP THE FITTING BOLTS FREE OF CONCRETE. SIZE 11 1/4' BEND 22 1/2' BEND 45' BEND 90' BEND TEE PLUG 4 12 12 12 16 16 14 6 12 12 12 16 16 14 8 12 12 16 22 22 18 10 12 14 20 28 28 22 12 12 18 24 32 32 28 14 14 20 28 38 38 32 16 16 22 32 42 42 36 18 18 26 36 48 48 40 20 20 28 40 52 52 44 24 24 34 46 64 64 54 30 30 42 58 78 78 66 36 36 50 70 94 94 80 42 40 58 80 108 108 92 48 46 66 90 124 124 104 THRUST BLOCKS - DIMENSION "A" 1 1 12/O7I UTILITIES, INC. LOGO ADDED NO. DATE REVISION SAO BY WATER DETAILS TYPICAL THRUST BLOCK FOR PLUGS FILE NO. SCALE: N.T.S. DATE: AUG. 2003 570€ Westpark Or., Suite 101 STANDARD Utilities,• Inc- P.O. Box 240908 DETAIL NUMBER Charlotte, N.C. 28224-0908 one NC/IN Aff:ialf= (704) 525-7990 YY — 8 0 CO U Z.o es irs EMS rQQ E Z • M N > Z 11 S AL 6988 : i ClfEllt 9/19/2017 CAROLINA WATER SERVICE, INC OF NC DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 SEE STD. DETAIL N0. S-5 11=11-1[=1111E, 24" PROVIDE FLEXIBLE BOOT PER ASTM C443 & C923 3 COURSES OF BRICK MAX. JOINT STEP - SEE STD. DETAIL N0. S-4 STRAIGHT WALL OF' M.H. TO SE LOCATED OVER INFLUENT PIPE 4'-0" OR 5'-O" 5" MIN. PLACE ON UNDISTURBED EARTH OR COMPACTED FILL MATERIAL CONCRETE SUPPORT COLLAR FLEXIBLE BOOT SEE NOTE #15 NO. 1 DATE REVISION Z ro w 7C 1 12/07 UTILITIES, INC. LOGO ADDED NOTES: SAO BY 1. MANHOLE TO CONFORM WITH ASTM C478-72 EXCEPT AS MODIFIED BELOW. 2. MANHOLE BASE TO BE REINFORCED WITH A MINIMUM AREA OF 0.20 SQ. IN. PER LINEAR FOOT EACH WAY AND BENT UP AT WALLS 10" AND SPLICED TO WALL REINFORCING. WALL REINFORCING TO BA A MINIMUM OF 0.12 SQ. IN. PER LINEAR FOOT. BOTH TONGUE AND GROOVE OF JOINTS SHALL HAVE REINFORCING EQUAL IN AREA TO MINIMUM OF WALL SECTION. 3. ALL JOINTS SHALL CONFORM WITH ASTM C443-63 4. STEPS TO BE PLASTIC, 5. ALL PIPE OPENINGS TO BE NO GREATER THAN 3" LARGER THAN O.D. OF PIPE AND ADDITION- ALLY REINFORCED WITH A MINIMUM OF 0.20 SQ. IN. OF STEEL AT 90 DEGREES. PIPE TO BE CENTERED IN OPENINGS AND SUPPORTED WITH A CONCRETE COLLAR 12" GREATED THAN O.D. OF PIPE FOR ONE FOOT FROM THE WALL. CONCRETE SHALL BE FORCED FROM THE OUTSIDE TO BECOME AN INTREGAL PART OF THE MANHOLE INVERT OR TO A POINT FLUSH WITH INSIDE WALL. 6. ALL SURFACES SHALL BE SMOOTH EVEN TEXTURED WITH A MINIMUM OF HONEYCOMB, FINS AND OTHER INPERFECTIONS 7, LIFTING HOLES SHALL BE PLUGGED FROM OUTSIDE PRIOR TO BACKFILLING 8. INVERTS IN 5' DIAMETER MANHOLES TO BE 3600 PSI READY MIX CONCRETE IN LIEU OF BRICK 9. STEPS IN 5' DIAMETER MANHOLES TO BE OVER WIDEST SHELF. 10. ALL MASONRY MORTAR SHALL BE PORTLAND CEMENT 1 : 3 MIX. 11. CARE MUST BE TAKEN TO FORM A SMOOTH FINISHED TROUGH FROM ENTRANCE PIPES TO EXIT PIPE, AND IN CURVED MANHOLES THE TROUGH MUST BE A SMOOTH CIRCULAR ARC TANGENT TO THE INSIDE WALLS OF THE PIPES AT THEIR ENDS. 12. RAMSET MASONRY TIES EVERY 12 INCHES. 13. JOINTS TO BE THOROUGHLY SEALED WITH FLEXIBLE VULCANIZED BUTYL RUBBER TO PREVENT INFILTRATION. 14. ALL MANHOLES OVER 16' TOTAL DEPTH SHALL HAVE OSHA APPROVED STAINLESS STEEL LADDER IN LIEU OF MANHOLE STEPS 15. ALL PIPE CONNECTIONS SHALL CONSIST OF AN APPROVED CONTINUOUS BOOT OF 3/8" MINIMUM THICKNESS NEOPRENE CONFORMING TO ASTM C923. INSTALLED BOOT SHALL RESULT IN A WATER -TIGHT CONNECTION MEETING THE PERFORMANCE REQUIREMENTS OF AS1M C443. SANITARY SEWER DETAILS PRECAST MANHOLE 4' AND 5' DIAMETER FILE NO. SCALE: N.T.S. DATE: AUG. 2003 Utilities Inc. 5701 Westpork Or., Suite 101 STANDARD P.O. Sox 240908 DETAIL NUMBER Charlotte, N.C. 28224-0908 (704) 525-7990 S-1 22-1/2' OR 45' BEND EXISTING OR FINISHED GRADE 1 L 1� L 1 Ll! 11 v! �I I i-I E 1--III-III-I 1 I -III --I 11-III -III„11 I lIiII I II 111 11il i lT1=111= 1.11 11Iw LATERAL PIPE WITH LESS THAN 3' COVER MUST BE DIP USE AIRTIGHT CONNECTOR FOR TRANSITION VARIES WITH SLOPE D" x 4" TEE D = DIAMETER OF MAIN LINE PIPE PVC OR DIP 4" CAST IRON SOIL PIPE OR PVC PIPE WITH APPROVED GASKET SYSTEM NOTES: 1. IF TEE IS DUCTILE IRON, BEND AND LATERAL PIPE MUST BE DUCTILE IRON. 2. IF TEE IS PVC, BEND AND LATERAL PIPE MUST BE PVC. 3. TEE AND BEND TO BE FULLY ENCASED IN #67 CRUSHED STONE. 4. INSTALL ELDER VALVE AT PROPERTY LINE. SEE STD. DETAIL S-14. 1 I 12/07 UTILITIES. INC. LOGO ADDED NO. ATE EvISION SAO BY SANITARY SEWER DETAILS 4" LATERAL (TEE) FILE NO. SCALE: N.F.S. DATE: AUG. 2003 STANDARD 4 r 5701 Westpork Or., Suite 101 DETAIL NUMBER Uiillf%s. %g 0horlotte. N.C.08 224-0908 and NC/TN Atfillotr,N(704) 525-7990 S 11 7" MIN. SEE STD. DETAIL NO. 5-5 3 COURSES OF BRICK MAX, 9' JOINT DIP (MIN) OR DIP TO UNDISTURBED GROUND C-900 PVC PLASTIC PIPE STRAIGHT WALL OF M.H. TO BE LOCATED OVER INFLUENT PIPE OR OVER WIDEST SHELF 1 NO. volD TO BE MASONRY FILLED 4'-0" OR 5'-O" 3 - #6 REBARS POUR 3'x 3' CONCRETE FOOTING, 6"THICK TO SUPPORT DROP IN STRUCTURE FLEXIBLE 800T (SEE NOTE #15 STD. DETAIL S-1) 12/07 UTILITIES. INC. LOGO ADDED DATE REVISION NOTES: SAO BY 1. MANHOLE TO CONFORM WITH ASTM C478-72 EXCEPT AS MODIFIED BELOW. 2. MANHOLE BASE TO BE REINFORCED WITH A MINIMUM AREA OF 0.20 SQ. IN. PER LINEAR FOOT EACH WAY AND BENT UP AT WALLS 10" AND SPLICED TO WALL REINFORCING. WALL REINFORCING TO BA A MINIMUM OF 0.12 SQ. IN. PER LINEAR FOOT. BOTH TONGUE AND GROOVE OF JOINTS SHALL HAVE REINFORCING EQUAL 1N AREA TO MINIMUM OF WALL SECTION. 3. ALL JOINTS SHALL CONFORM WITH ASTM C443-63 4. STEPS TO BE PLASTIC. 5. ALL PIPE OPENINGS TO BE NO GREATER THAN 3" LARGER THAN O.D. OF PIPE AND ADDITION- ALLY REINFORCED WITH A MINIMUM OF 0.20 SQ. IN. OF STEEL AT 90 DEGREES. PIPE TO BE CENTERED IN OPENINGS AND SUPPORTED WITH A CONCRETE COLLAR 12" GREATED THAN 0.0. OF PIPE FOR ONE FOOT FROM THE WALL. CONCRETE SHALL BE FORCED FROM THE OUTSIDE TO BECOME AN INTREGAL PART OF THE MANHOLE INVERT OR TO A POINT FLUSH WITH INSIDE WALL. 6. ALL SURFACES SHALL BE SMOOTH EVEN TEXTURED WITH A MINIMUM OF HONEYCOMB, FINS AND OTHER INPERFECTIONS 7. LIFTING HOLES SHALL BE PLUGGED FROM OUTSIDE PRIOR TO BACKFILLING 8. INVERTS IN 5' DIAMETER MANHOLES TO BE 3600 PSI READY MIX CONCRETE IN LIEU OF BRICK 9. STEPS IN 5' DIAMETER MANHOLES TO BE OVER WIDEST SHELF. 10, ALL MASONRY MORTAR SHALL BE PORTLAND CEMENT 1 : 3 MIX. 11. CARE MUST BE TAKEN TO FORM A SMOOTH FINISHED TROUGH FROM ENTRANCE •PIPES TO EXIT PIPE, AND IN CURVED MANHOLES THE TROUGH MUST BE A SMOOTH CIRCULAR ARC TANGENT TO THE INSIDE WALLS OF THE PIPES AT THEIR ENDS. 12. RAMSET MASONRY TIES EVERY 12 INCHES. 13. PROTECTIVE WALL FOR OUTSIDE DROP SHALL BE A MINIMUM OF 4" MASONRY, AN 8" WALL MAY BE REQUIRED UNDER SOME CONDITIONS. 14. THE SLOPE OF THE OUTSIDE DROP TROUGH SHALL BE 1/4" PER FOOT. 15. DROP STRUCTURE MAY BE FORMED AND POURED OF 3600 PSI CONCRETE IN LIEU OF MASONRY. 16. FOOTING FOR DROP MAY BE POURED AS PART OF THE MANHOLE BASE SLAB OR FIELD POURED AND TIED TO MANHOLE BASE WITH THREE EQUALLY SPACED #6 REBARS DOWELED INTO MANHOLE BASE 2" FROM TOP OF SLAB. GROUT INTO 8" DEEP HOLES WITH EXPANSION GROUT. 17. OUTSIDE DROP SHALL NOT ENTER MANHOLE IN CONE SECTION. 18. JOINTS TO BE THOROUGHLY SEALED WITH FLEXIBLE VULCANIZED BUTYL RUBBER TO PREVENT INFILTRATION. 19. ALL MANHOLES OVER 16' TOTAL DEPTH SHALL HAVE OSHA APPROVED STAINLESS STEEL LADDER IN LIEU OF MANHOLE STEPS FILE NO. SANITARY SEWER DETAILS SCALE: N.T.S. PRECAST MANHOLE W/ OUTSIDE DROP DATE: 2003 4' AND 5' DIAMETER 5701 wcstpork Dr., Suite 101 STANDARD l P.Q. Box 2a0908 DETAIL NUMBER Utl�ES�. 'JTi�" Charlotte, N.C. 28224-0908 and NC/TN Al9liote (704) 525-7990 S-2 1/2" (2) TYPE ONE PICKSLOTS (2) 1" VENT HOLES COVER FACE COVER BACK 1/8" COVER SECTION ESTIMATED WEIGHT VULCAN TYPE V-1383 LOAD RATING - HEAVY DUTY FRAME COVER TOTAL 240 LBS. 145 LBS. 385 LBS. I1 112/07I UTILITIES, INC. LOGO ADDED NO. DATE REVISION SURFACE TO BE MACHINED 1/2" 7 3/4„ -&-7/8„ PICKSLOT DETAIL FRAME PLAN 25-1 /4" 23-1/2" 1-1/4" 25-1/4" 34-1/2" SAO BY FRAME SECTION NOTE: SOLID LID WHERE INFILTRATION IS POSSIBLE, LOCKING LID IN YARDS AND PUBLIC AREAS. SANITARY SEWER DETAILS MANHOLE RING & COVER FILE NO. SCALE: N.T.S. DATE: AUG. 2003 5701 wcstpork 0r,. Suits 101 STANDARD Utilities, Inc- P.O. Box 240908 DETAIL NUMBER - Charlotte, N.C. 28224-0908 and NC/TN Af liiole. (704) 525-7990 S-5 ( 1 0 1 1 /8" i Q 10-3/4" 12" COPOLYMER POLYPROPYLENE PLASTIC 5- 3/4" 1/2" GRADE 60 STEEL REINFORCEMENT NOTE: THIS STEP TO BE DRIVEN INTO TAPERED HOLES IN PRECAST MANHOLE SECTIONS. DO NOT USE AS A GROUTED -IN STEP. ,IIIIIIIIIIIII1,I 4 i NO. 12/07 UTILITIES, INC. LOGO ADDED DATE R:Ev1S10N SAO BY -1/4" SECTION A -A SANITARY SEWER DETAILS PLASTIC STEP FOR PRECAST MANHOLES FILE NO, SCALE: N.T.S. DATE: AUG. 2003 Utilities, f� p 5701 Westpark Or.. Suite, 101 STANDARD Utilities, Inc'. P.O. Box 240908 DETAIL NUMBER Charlotte,, N.C. 28224--0908 and NC/TN Afrn:ate (704) 525-7990 S-4 a CO Z O m re, cti P E g LL 0 pL81 0A y a> • q M474 ai% V' b0 z L, tNo 1N 5 Z SIG •, may: •� CORPORATE . SEAL • = :moo: ..1,,4�: ifI11111+ /1//' j1fC.Ili1l 9/19/2017 CAROLINA WATER SERVICE, INC OF NC Ce W 0 Cn z W REVISIONS: §2 u Z c.oc000ye wt2>0G ±J li; 000uo'tna DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 '/(1". 6" PLUG VALVE IN VALVE BOX, TYP 6" FLANGE, TYP BY MANUFACTURER 6" DIA SS PIPE STUB, TYP BY MANUFACTURER TANK WALL, TYP .a 4 4 CONQRETE FOUNDATION (SEE STRUCTURAL? PLAN) A TYPICAL SBR DRAIN 4.1 C6.9 ELEVATION B SOLBERG SILENCERS NOTES: 1. SILENCER TO BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. 2. SOLBERG SILENCERS ARE USED TO PROTECT BLOWER PACKAGE AIR INTAKE FROM LARGE DEBRIS AND WILDLIFE WHEN INTAKE AIR IS BEING DUCTED FROM OUTDOORS. 3. OUTDOOR SILENCER HAS NO FILTER ELEMENT, ONLY A STAINLESS STEEL MESH SCREEN FOR LARGE DEBRIS. THE SOLBERG UNIT SERVES AS A PIPE NOISE SILENCER AND WEATHER HOOD. 4. SILENCER TO BE FINISHED WITH BAKED -ON ENAMEL FOR OUTDOOR USE. 5. ALL SILENCERS SHALL INCLUDE A STAINLESS STEEL ELEMENT. NTS BLOWER MODEL RATED FLOW (SCFM) OUTLET SIZE STYLE OUTLET CONNECTION A B C WEIGHT (LBS) AERZEN PART No. SOLBERG PART No.** REPLACEMENT ELEMENT No.** 4S & 10S 520 4" COMPACT FLANGE 14" 4" 16" 44 21-000648-04-S 2G-274S-400F 274S 25S 1100 6" COMPACT . FLANGE 15" 5" 16" 47 21-000648-06-1 2G-274S-600F 274S "(41 BLOWER INLET SILENCER C6.9 SECTION NOTE: CONTRACTOR TO INSTALL SLEEVE AND SEAL PER MANUFACTURER'S SPECIFICATIONS CONFIRM REQUIRED SIZE AND LOCATION OF PIPE, SLEEVE, AND SEAL PRIOR TO START OF CONSTRUCTION 6 WALL PENETRATION MODULAR TYPE WALL PENETRATION ELASTOMERIC SEAL STAINLESS STEEL BOLT, TYP PRESSURE PLATE STEEL WALL SLEEVE WALL ANCHOR COLLAR WITH 2" WATER STOP CONTINUOUSLY WELDED ON BOTH SIDES NTS C6.9 SECTION NTS SOLBERG BLOWER INLET SILENCER, TYP SEE AERATION PIPING PLAN AND SILENCER DETAIL FOR ADDITIONAL INFORMATION BLOWER INLET PIPING SEE AERATION PIPING PLAN FOR SIZE SEE WALL PENETRATION DETAIL PIPE STANCHION FIELD CUT AND WELDED TO FIT BLOWER OUTLET PIPING SEE AERATION PIPING PLAN FOR SIZES NOTE: BLOWER PIPING MAY BE CL 50 DIP OR GALVANIZED STEEL OR SCH. 40 STEEL PIPE. ALL EXPOSED PIPING SHALL BE PAINTED 2 COATS OF ENAMEL PER OWNER'S COLOR SELECTION. ALL CONNECTS SHALL BE MADE PER MANUFACTURER'S SPECIFICATIONS. SEE AERATION PIPING PLAN FOR LAYOUT AND SIZING. BUTTERFLY VALVE (SUPPLIED BY CONTRACTOR) SEE AERATION PIPING PLAN FOR ADDITIONAL INFORMATION BLOWER INLET CONNECTION SEE BLOWER INLET CONNECTION DETAIL ;Icon [Mu:dab:40"A FILTER (SHOWN REMOVED) POSITIVE DISPLACEMENT BLOWER IN SOUND ENCLOSURE, TYP SEE BLOWER BUILDING LAYOUT AND AERATION PIPING PLANS FOR ADDITIONAL INFORMATION FLEXIBLE CONNECTION, ONE-WAY VALVE, & OUTLET FLANGE PROVIDED BY BLOWER MANUFACTURER BUTTERFLY VALVE (SUPPLIED BY SBR MANUFACTURER) SEE AERATION PIPING PLAN FOR ADDITIONAL INFORMATION TYPICAL BLOWER CONNECTIONS C6.9 j SECTION 3' X 3' X 4" (T) CONCRETE PAD SEE SITE PLAN FOR ORIENTATION 6" DIP SEE PIPING PLAN FOR CONTINUATION 5 PLAN 4" 316 SS CAM & GROOVE QUICK CONNECT - FOR PUMPER TRUCK W! 4" DUST CAP (NOT SHOWN) FINAL GRADE *30" (TYP) 6" X 4" REDUCER STEEL BOLLARD (SEE DETAIL) *4" OFF OF EDGE OF PAD SLUDGE REMOVAL CONNECTION a. 4 . NTS 6" 90" VERT. BEND 3'X3'X4"(T) CONCRETE PAD SECTION 6" 90` VERT. BEND C6.9 NOTE: CONTRACTOR TO INSTALL SLEEVE, SEAL, AND EXPANSION JOINT PER MANUFACTURER'S SPECIFICATIONS PLAN / SECTION CONFIRM REQUIRED SIZE AND LOCATION OF PIPE, SLEEVE, SEAL, AND EXPANSION JOINT PRIOR TO START OF CONSTRUCTION EBAA FLEX -TEND® (FJ-FJ) FLEXIBLE EXPANSION JOINT SEE INDIVIDUAL PLAN SHEETS FOR PIPE SIZE 7 MODULAR TYPE WALL PENETRATION ELASTOMERIC SEAL 1 STAINLESS STEEL BOLT, TYP RESILIENT WATERPROOF CAULKING -1 I 4 . WA,.L 4 r/ // / // 1.1 // // // // // /, ANCHOR COLLAR WITH 2" WATER STOP CONTINUOUSLY WELDED ON BOTH SIDES WALL STEEL WALL SLEEVE WALL PENETRATION - BELOW GRADE NTS a v 4 SECTION NTS NOTE: 1. THIS DRAWING PROVIDED FOR REFERENCE ONLY 2. CONTRACTOR SHALL VERIFY INFORMATION WITH OWNER PRIOR TO CONSTRUCTION. 3. ALL CONNECTS SHALL BE MADE PER MANUFACTURER'S SPECIFICATIONS. 4. SEE AERATION PIPING PLAN FOR LAYOUT AND SIZING. POSITIVE DISPLACEMENT BLOWER IN SOUND ENCLOSURE, TYP BUTTERFLY VALVE BUTTERFLY VALVE AERZEN 4S & 10S 0 88.9 [3.50"] CUSTOMER PIPE CONNECTION 100.0 (3.94"] AERZEN DISCHARGE 10.0 GAp. [0.391 40.0 [1.57'1 *CUSTOMER PIPE ENGAGEMENT IN FLEX CONNECTION LEAVES .4" GAP 0141.3 [5.561 AER7FN 25-S MNla1 mum Hp CUSTOMER PIPE CONNECTION 150.0 [5.90"] AERZEN DISCHARGE 10.0 GAP [0.391 70.0 [2.761 CUSTOMER PIPE ENGAGEMENT IN FLEX CONNECTION LEAVES .4" GAP !3TYP1CAL BLOWER INLET SLEEVE CONNECTION SECTION VERTICAL CLOSE COUPLED SOLIDS HANDLING PUMP PROVIDED BY SBR MANUFACTURER TO BE INSTALLED BY CONTRACTOR PER PUMP MANUFACTURER'S SPECIFICATIONS PROP ECCENTRIC EXPANDER SEE UTILITY PLAN FOR SIZE 1 i I DISCHARGE SUCTION 6" (r) CONCRETE EQUIPMENT BASE SEE UTILITY PLAN, STRUCTURAL PLAN, & MANUFACTURER'S SPECIFICATIONS 4 4 • a 4. ° 4 4 CONCRETE FOUNDATION 4 (SEE STRUCTURAL PLAN). •4 ' 44 4 4 .4 a.' 4 JET AER8ATION PUMP SETTING PLAN ELEVATION C6.9 NTS NTS "D`ESIG'1y''%1/ CORPORATE � LSEAL.Ip' ;;;;()��'FNGINf 9/19/2017 L z 1 z <Zo LL- W W � W U W cn F- LU Z f= Z - OCL z o__ 1- z W 0 5 c S za 0 0 co U �M �cf) 0 H` NO2 cCO?�mUZ- (30m00cn 0.zZ>a% c.umE9; 0000cYv)a a • DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 PROP. 8" 90° VERTICAL BEND PROP. 8" 90° VERTICAL BEND PROP. 8" GATE VALVE PROP. 8" X 12" EXPANDER PROP. ULTRAVIOLET DISINFECTION UNIT, PROVIDED BY OWNER 8" DIP CLOTH MEDIA FILTER PROVIDED BY OWNER BLOCKING BY CONTRACTOR PER MANUFACTURERS SPECIFICATION FILTER TO UV PIPING ELEVATION NOTE: SEE STRUCTURAL PLANS FOR ADDITIONAL SUPPORT INFORMATION SEE PIPING DETAIL FOR CONNECTIONS SEE BUILDING LAYOUT FOR LOCATION IN SLAB PROP. 304 SS 120° V-NOTCH WEIR BOX SUPPLIED BY OWNER SEE SHEET C6.11 �=111 M_II a' 4 1.�„ L I iIEIII I FLOOR PROP. 8" TEE BRANCH TO SECOND UV UNIT 8" GATE VALVE IN BRANCH PROP. 12" X 10" REDUCER PIPING FROM PROP. ULTRAVIOLET DISINFECTION UNIT PROP. 10" 90° VERTICAL BEND ROMACARMOR-LINKTM FLEXIBLE COUPLING OR APPROVED EQUAL EACH END I -I I I lI 1 I t I �1I I!TT-I FLOW MONITORING WEIR BOX � � T NTS 7 SECTION DESCRIPTION: LAYOUT, UV3000PTP-3001 M 1 CHANNEL 1 BANK 4 LAMPS WEIR MULTIPLE CHANNELS IN PARALLEL (OPTION): : ADDITIONAL UNITS CAN BE INSTALLED PARAUE1. TO THE UNIT SHOWN. : ACCESS IS REQUIRED BETWEEN CHANNELS FOR MODULE REMOVAL - NOTE THE CHANNEL. WIDM MD ENSURE ADEQUATE NXESS IS PROVIDED BETWEEN TPMNSTRiON BOXES AND CHANNELS. NOTES: : DO EQI SLOPE CHARNEL FLOOR. : CHANNEL WIDTH & DEPTH MUST BE KEPT WITHIN A TOLERANCE OF + OR - 1i' [6]. : ANCHOR BOLTS ARE 1!!4I SUPPLIED BY TROJAN TECHNOLOGIES. : BOLTS. WASHERS & NUTS FOR CONNECTION OF CHANNEL TO TRANSMON BOXES ARE PROMSDED BY TROJAN TECHNOLOGIES. : SYSTEM CONDUIT, WIRING, D1STR1BUTON PANELS lc INTERCONNECTIONS BY OTHERS. ELECTRICAL REQUIREMENTS SHOWN ARE TO SUPPLY TROJAN W EQUIPMENT ONLY. ELECTRICAL INRUSH FACTOR TO BE ADDED AS PER LOCAL CODE. : MY INTRA OUTLETS NOT BEING USED BY TROJAN EOUIPMENT HAVE 1 Q BEEN INCLUDED IN NE INTERCONNECT AMPERAGE. : CONTRACTOR TO REVIEW ALL TROJAN TECHNOLOGIES INSTALLATION INSTRUCTIONS PRIOR TO EQUIPMENT INSTALLATION. : ACCESS S REQUIRED FOR MODULE REMOVAL - NOTE THE CHANNEL WIDTH AND UNSURE ADEQUATE AUK S PROVIDED TO ALL MODULES. : DO #LQT ENCASE THE STEEL. CHANNEL. IN CONCRETE. : [ ] INDICATES MILLIMETERS UNLESS OTHERWISE SPECIFIED. EQUIPMENT GENERAL ARRANGEMENT DRAWING NOTES: 1 DRAWING NOT TO BE USED FOR CONSTRUCTION 2. EQUIPMENT TO BE SUPPLIED BY THE OWNER OR SBR MANUFACTURER SHALL BE INSTALLED BY THE CONTRACTOR ACCORDING TO MANUFACTURER'S SPECIFICATIONS. 3. THE OWNER SHALL PROVIDE SHOP DRAWINGS OF THE PROPOSED EQUIPMENT TO THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 4. CONTRACTOR SHALL CONFIRM ALL DIMENSIONS ON THE PROVIDED SHOP DRAWINGS ARE CONSISTENT WITH THOSE SHOWN IN THESE PLANS PRIOR TO THE START OF CONSTRUCTION. 5. DISCREPANCIES SHALL BE REPORTED TO THE OWNER AND THE ENGINEER IMMEDIATELY. NTS No. DESCRIPTION FROM TO 1 SPLfITER PANEL POWER SUPPLY 120V, 1 PHASE, 2 WIRE, ACTUAL DRAW 31.7 AMPS / SPUTTER PANEL MSTRIBU110N PLANS. OP) (N07 SHOWN) (BY OTHERS) SPLMER PANEL. (BY OTHERS) 2 PPOWER O Oa51 7TLON REcentr LE (POT) PPLY 120V, 1 PHLASE. 2 WIRE, ACTUAL DRAW 6.3 AMPS / PAR SPUTTER PANEL (BY OTHERS) Pat 3 SYSTEM MONITOR POWER SUPPLY 120V, 1 PHASE; 2 WIRE, 5 ALPS DP (NOT SHOWN) (BY OTHERS) SYSTEM MONITOR TROJAN UV - END VIEW AND NOTES END VIEW (TYPICAL) SCALE:AS SHOWN x-104" [872] HOLE & BOLT CIRCLE TO FIT 12.0 [3000] (FOR DIN. BS & JS) PIPE & FLANGE NOTE: PDR, SPUTTER PANEL. (BY OTHERS) OR SYSTEM MONITOR NOT SHOWN C6.10 NTS 2 r*dig! I L PROP. 12" X 10" REDUCER PROP. 10" 90° VERTICAL BEND PROP. 304 SS 120° V-NOTCH WEIR BOX SUPPLIED BY OWNER SEE SHEET C6.11 Iniarair A W `' TjL---- I (=4 11= ;t- ROMAC ARMOR LINKTM FLEXIBLE :�l l l COUPLING OR APPROVED EQUAL 11 EACH END ±iII=i E I=] 11- FILTER TO UV PIPING PROP. ULTRAVIOLET DISINFECTION UNIT SUPPLIED BY OWNER � w rr► w w RIIV 41LL► • � w 41R � w w► i S • BLOCKING BY CONTRACTOR ri[E f PER MANUFACTURERS j1-1 SPECIFICATION �s 11-1 -WI- 11=1 -1 I � -T_, - PROP. 10" TEE BRANCH TO WEIR INLET C6,10 r--5 ELEVATION EX. AERATION BASIN PROP. PIPE SUPPORT PROP. 8" 90° VERTICAL BEND,TYP PROP. 8" TEE 8" GV EACH BRANCH PROP. 8" DIP TEE EX. FORCE MAIN TO DISTRIBUTION BOX \\�\\�� ��� �\ /\ /\\ /\�\ PROP. 8" 90° VERTICAL BEND EX. AERATION BASIN WALL TEMPOARY AERATION BASIN CONNECTION NTS C6.10 (S SECTION Tr u -It- (t ( 3 DESCRIPTION: LAYOUT, UV3000PTP-3001M 1 CHANNEL 1 BANK 4 LAMPS WEIR STANDARD 30011A LEVEL CONTROL WEIR W/ DRAIN PLUG 1 [25] NPT WAU. MOUNTED SYSiDIE MONITOR MODULE LAMP STATUS VIEWDNO PLATE (TYPICAL) BANK 1A ACCESS PLATE VAN WARNING LABEL PLAN VIEW SCALE:AS SHOWN TROJAN UV - PLAN VIEW 1 %"o [MLOw /INCH N BBOLTS BO (8Y OTHERs) (31 FULL CIRCLE SUPPORT DETAIL NTS PIPE SUPPORT SUPPORT SIZE PIPE O.D. STRAP SIZE THREAD STUD BASE PLATE EXTENSION PIPE REQ'D MIN. DIST. TO FLOOR 3" 3.96" 3/8" x 2" 1" x 6" 4"x6"xYi" 2" SCH. 40 7" 4" 4.80" '/" x 2" 1" x 6" 8"x8"xW 2" SCH. 40 7" 6" 6.90" '/a" x 2" 1" x 6" 8"x8"x1/4" 2" SCH. 40 7" 8" 9.05" 14" x 2" 1" x 6" 8"x8"x1/4' 2" SCH. 40 7" 10" 11.10" Yz" x 2" 1" x 6" 8"x8"x%" 2" SCH. 40 7" 12" 13.20" Y2" x 2" 1" x 6" 8"x8"x%4" 2" SCH. 40 7" NOTES: FULL CIRCLE CLAMP SUPPORTS ARE TO BE FACTORY FABRICATED UNITS. NO CONTRACTOR FABRICATED SUPPORTS ARE ALLOWED. MATERIAL TO BE 304. STAINLESS STEEL. UPPER AND LOWER MATCHING SADDLES ARE EACH TO ENCOMPASS 170° OF PIPE, AND ARE TO BE FORMED TO ACTUAL PIPE DIAMETER. A NEOPRENE LINER IS REQUIRED WHEN SUPPORTING STEEL OR PVC PIPE. SUPPORT DESIGN SHALL HAVE BEEN TESTED TO WITHSTAND A MINIMUM OF 10,000 POUNDS COMPRESSIVE LOAD. TEST CERTIFICATION MUST BE AVAILABLE. SUPPORTS SHALL BE STANDON MODEL C92 AS MANUFACTURED BY -MATERIAL RESOURCES INC. OR APPROVED EQUAL. C6.1 6 NTS C6.10 EQUIPMENT GENERAL ARRANGEMENT DRAWING NOTES: 1. DRAWING NOT TO BE USED FOR CONSTRUCTION 2. EQUIPMENT TO BE SUPPLIED BY THE OWNER OR SBR MANUFACTURER SHALL BE INSTALLED BY THE CONTRACTOR ACCORDING TO MANUFACTURER'S SPECIFICATIONS. 3. THE OWNER SHALL PROVIDE SHOP DRAWINGS OF THE PROPOSED EQUIPMENT TO THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 4. CONTRACTOR SHALL CONFIRM ALL DIMENSIONS ON THE PROVIDED SHOP DRAWINGS ARE CONSISTENT WITH THOSE SHOWN IN THESE PLANS PRIOR TO THE START OF CONSTRUCTION. 5. DISCREPANCIES SHALL BE REPORTED TO THE OWNER AND THE ENGINEER IMMEDIATELY. C6.10 PLAN NTS 9 SECTION SPUTTER PANED. (BY OTHERS LOCATED WITHIN 10 Ft [3.048m OF POWER END OF TIODULE STANDARD PLUG W/ GROUND POWER CORD 10' POR () EFFLUENT PIPE (BY OTHERS) 12" [450] DRAM/PLUG) DESCRIPTION: LAYOUT. UV3000PTP-3001M 1 CHANNEL 1 BANK 4 LAMPS WEIR WALL MOUNTED SYSTEM MONITOR LOCATED WITHIN 15 Ft [4.572m] OF CHANNEL STANDARD 3001M LEVEL CONTROL WEIR EL�0.00' j0.004m3• 13•^7k[41 FRONT VIEW SCALE:AS SHOWN [�) TROJAN UV -ELEVATION 4-84 UV3000PTP-1N3001M MODULE 10 REQUIRED / BANK REAOVABLE COVER PLATE (TYPICAL) TRN4SUTON BOX () INFLUENT PIPE f(BY OTHERS) [816] NTS EQUIPMENT GENERAL ARRANGEMENT DRAWING NOTES: 1. DRAWING NOT TO BE USED FOR CONSTRUCTION 2. EQUIPMENT TO BE SUPPLIED BY THE OWNER OR SBR MANUFACTURER SHALL BE INSTALLED BY THE CONTRACTOR ACCORDING TO MANUFACTURER'S SPECIFICATIONS. 3. THE OWNER SHALL PROVIDE SHOP DRAWINGS OF THE PROPOSED EQUIPMENT TO THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 4. CONTRACTOR SHALL CONFIRM ALL DIMENSIONS ON THE PROVIDED SHOP DRAWINGS ARE CONSISTENT WITH THOSE SHOWN IN THESE PLANS PRIOR TO THE START OF CONSTRUCTION. 5. DISCREPANCIES SHALL BE REPORTED TO THE OWNER AND THE ENGINEER IMMEDIATELY. C6.10 ELEVATION NTS Lt1111111ll/ CORPORATE w •SEAL .,,/// CAR l/tirisEEillto S'AL 6988 '�i4•• CINE� '''' 4FNlC ILHl \ 9/ 19/20 17 u ■ L <20 L .L W z W UJ u' WU5 F- ,E15, v) LLI w Z 0 uQ-5 • DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 G E D A 8 7 1 6 FREE -FLOW CAPACITY: 34.76 GPM [2.194 US] MINIMUM - 796.7 GPM [60.36 US] MAXIMUM FLOW—al- 010" [25.40 CM] 9" [22.86 CM] Ha POINT OF MEASUREMENT 5 [43.18 CM] 141.,. ‘_ -4 _ .,... __., _____ 120° V-NOTCH _ o 1 I I°1 WEIR PLATE -:3---FIXED UNDERFLOW BAFFLE PLATE L ° 2" [5.08 CM] TOP FLANGE 3'-6" [106.68 CM] PLAN VIEW EXTERNAL STIFFENING RIB 9„ [22.86 CM] 010" [25.40 CM] 1'-8 1/4" [51.44 CM] 6 3/4" [17.15 CM] 8" [20.32 CM] H 1'-8 1/4" [51.44 CM] 6 3/4" [17.15 CM] REV REVISION DESCRIPTION 8 BY. 7 DATE 5' [152.40 CM] RIGHT ELEVATION VIEW NOTES: 1) 11 GAUGE POLISHED STAINLESS STEEL CONSTRUCTION 2) STRUCTURE TO BE SELF-SUPPORTING WHEN FULL 3) ANCHOR CLIPS DRILLED FOR 5/8" [1.59 CM] 0 HOLES 3 2 EQUIPMENT GENERAL ARRANGEMENT DRAWING NOTES: 1. DRAWING NOT TO BE USED FOR CONSTRUCTION 2. EQUIPMENT TO BE SUPPLIED BY THE OWNER OR SBR MANUFACTURER SHALL BE INSTALLED BY THE CONTRACTOR ACCORDING TO MANUFACTURER'S SPECIFICATIONS. 3. THE OWNER SHALL PROVIDE SHOP DRAWINGS OF THE PROPOSED EQUIPMENT TO THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 4. CONTRACTOR SHALL CONFIRM ALL DIMENSIONS ON THE PROVIDED SHOP DRAWINGS ARE CONSISTENT WITH THOSE SHOWN IN THESE PLANS PRIOR TO THE START OF CONSTRUCTION. 5. DISCREPANCIES SHALL BE REPORTED TO THE OWNER AND THE ENGINEER IMMEDIATELY. 6-2 45/64" [159.25 CM] 1'-5 3/4" [45.09 CM] \ \ /-0 -/' DISCHARGE ELEVATION VIEW This drawing and the data contained within is the sole, confidential property of OPENCHANNELFLOW (OCF) and may not be copied, reproduced, disclosed to others, in whole or in part, without the prior written consent of OCF. OCF reserves the right to change any dimension, finish, material, or method of construction indicated on this drawing at will and without notice. This drawing is provided in confidence with the understanding it shall be returned to OCF upon demand. 5 4 3 OPENCHANNELFLOW BOISE I ATLANTA H G DWG WB-S4-CV120-10P-N-N-N-N-N (1) DATE 08.25.17 E T-304 STAINLESS STEEL° V NOTCH WEIR BOX WITH 010" STUBS Unless otherwise indicated, dimensions are in feet and inches, with centimeters indicated in [ ]. Angles are in degrees. 2 1 B A cV cs c0 N clt Z.o o e"i co M al M ss E " (e, PI 71 _ �goU a rM3 ZLi 3 w `c Z v. CORPORATE SEAL SEAL 6988 7.1 9/I9/2017 0 z LL <zo W E W W b Ll1 U W to W W W H Z IOC Z r Z .wl 0 Q O LL 6cL DETAILS -WEIR BOX z 0 N_ cc DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 Item No. Quantity Description FFPhd 160424 Tankage, 304 SS a Filter HWL / BW Init Level (See Critical Note) Tank Effluent Control Weir Filter Control Panel, Conduit not shown for clarity FFPTM Filter Element (Typ 4 Places) Influent Valve, 4" (Typ 4 Places) Valve Actuator Not shown for clarity Backwash Valve, 6" (Typ 4 Places) Vaives and manifold not shown for clarity Backwash Manifold, 6" wl Blind Flange One End Only i . MINN ;it I •i Nominal Element Centers —54.5" • Co .46 to 0 (0 to w Air Vent Header Tank Overflow, 6" Flange shown (See Critical Notes) Influent Connection, 8" Flange Influent Valve, 4" (Typ 4 places) Backwash Valve, 6" (Typ 4 places) Backwash .I Manifold, 6" —.. —..-- ..- Backwash Rate Control Valve, 6" Critical Notes: - Filter Influent HWL (backwash initiation float level) is set approximately 2" below the overflow weir. Engineer shall design all elevations and hydraulics to accommodate all water levels expected in the filter influent channel, including flow up to and over the overflow weir. - Overflow flange as shown is sized to match BW piping and is not designed to accommodate 100% of influent flow. Overflow box dimensions and flange diameter may need to be significantly larger for systems with pumped influent or significant hydraulic peaking factors where full bypass or overflow potential is desired. Notes: - All Tank materials & fasteners to be Type 304 Stainless Steel or other non -corrosive materials. All piping to be Schedule 10 Stainless Steel. All connections to be ANSI standard 125 lb Flanges. - Nominal assembly / dry weight: 3800 Lbs. Nominal operating / wet weight: 12,200 Lbs. - All piping and piping connections to and from filter by others. - Filter shall be mounted to concrete floor or pad and anchored with stainless steel anchorage. Concrete, pad, anchors, design, and installation by others. - Manual Hoist for element removal not shown. - Compressed air source ©90psi required to operate valves & air scour system. - Filter control panel (FCP) factory mounted to tank at influent side. Conduit and wiring for incoming power (120VAC, 1 ph, 20AMP) by others. - FCP may be optionally shipped loose for field mounting remotely by others with J-Box mounted to filters influent side. Conduit & wiring between remotely mounted FCP and Tank mounted J-Box by others. 5.5" 77.5" Lay Length Air Scour Vent Hose w/ Coupler, 2" ID (Typ 4 Places) 93't Air Scour Supply Hose, w/ coupler 3/" ID (Typ 4 Places) Algae Cover Hoist Socket (Typ 2 Places) Effluent Connection, 8" Flange Air Valve, 3/4" (Typ 4 Places) Air Scour Manifold Common Air Connection '/2" NPT-F Filter Underdrain (Typ 4 Places) Drawing for general layout and sizing purposes only, NOT FOR FABRICATION This DraWrg and all appurtenant matter oontains Information proprietary to Fluidyne Corporation and is loaned subject to return upon demand and must not be reproduced. copied. termed. revealed. nor used for any Water purpose than that for which it was specifically furnished without expressed written consent from Ftuidyne Corporation. FLUIDYNE FFPrm FFPTM Cloth Media Filter — General Arrangement DRAWN DATE PROJECT FILE Engr 100616 Connestee Falls, NC F160024-Connestee-GAvsdx REV NA DATE Date DATE DRAWING SHEET F160424-GA 1 of 2 Hoist Socket, 1 per 2 elements Air Scour Supply Piping, %" (Typ 4 Places) Effluent Control Weir, Fixed FFPTM Filter Elements (Typ 4 Places) Influent Valves, 4" (Typ 4 places) Valve actuators not shown for clarity Backwash Valve, 6" (Typ 4 places) Valve actuators not shown for clarity Backwash Manifold w/ 6" Flange and Blind Flange One End Only Filter Control Panel, Tank Mounted Air Scour Manifold r—. 0 0 0 0 IFo Fo toy ley iii . t1II 0 �ay � Fel- -'"tlil1 CI inima=ley . IFo IFct-.... IF IF�I- IFo . --1�y1 13d! Ill on_,,.,, �� 11111 maul. 1. IF~ F 111 j"al_.. _ i�1 I3 � Fat 0 isyl Ir, Fol_... a4 Fsl- 4:,..Fcl= FcI- .... -u4 =134ill Fcl_ sz Fol=. =154 0 =lay Oct_ —_1----T-4--r-----r---r.___--.---r----r— '* /I ^ 2. l 1,-- ^ III /I ^ ^ II /1,.—.,1 y T` f 4. Y� i4 T, ' i 40. t ' t t 'r si \� �i T W Ti \T Ti 1: i 1 I � i I 1 I I Overflow ......"1 I 1 I I 1 6" 52" Backwash Manifold Lay Length (-54.5" w/ Rate Valve) Effluent Connection 8" Flange CO co • Influent Connection, 8" Flange & Overflow Connection, 6" Flange shown (See GA Critical Notes) Notes: - The following components are not shown for clarity: Air vent header & hoses, pneumatic valve actuators, air scour supply hose, conduit, fasteners, anchorage, covers, hoists, and piping connections. - Filter control panel (FCP) may be optionally shipped loose for field mounting near the filter or remotely. Conduit from Remote mounted FCP to filter junction box (not shown) by others. - Work with drawing F160424-GA Drawing for general layout and sizing purposes only, NOT FOR FABRICATION This Drawing and sit appurtenant matter contains Information proprietary to Fluidyne Corporation and Is loaned subject to return upon demand and must not be reproduced, copied. loaned. revealed. nor used for any other purpose than that for which it was specifically furnished without expressed written consent from Fluidyne Corporation. FLUIDYNE FFP FFPTM Cloth Media Filter — General Arrangement DRAWN REV Engr DATE 100616 NA DATE Date PROJECT FILE Connestee Falls, NC F160024-Connestee-GAvsdx SCALE DRAWING F 160424-GA Sti5ET1 of 2 Filter Panel Power (120VAC, 1ph, 60Hz, 20A) �-- Ethernet Connection ci— (Optional) Customer 0— Compressor Power Filter Control Panel (FCP) Factory mounted to influent end of filter #1 (see GA drawings) sTop of Hoist (at insertion) 13.0 Ft Top of Hoist (inserted) 12.33 Ft 4 Top of Tankage @ Vent 8.58Ft Influent Normal Operating Level, 5.35 Ft Top of concrete y 0.0 Ft / /\`// / Regulator & Filter (sum) 'A" NPT(F) 11 0o Coalescing Filter (lum) Ys" NPT(F) Concrete Pad Dimensions & Thickness by Engineer Filter #1 Air Scour . Manifold Common Connection Point 'A" NPT(F) EQUIPMENT GENERAL ARRANGEMENT DRAWING NOTES: 1. DRAWING NOT TO BE USED FOR CONSTRUCTION 2. EQUIPMENT TO BE SUPPLIED BY THE OWNER OR SBR MANUFACTURER SHALL BE INSTALLED BY THE CONTRACTOR ACCORDING TO MANUFACTURER'S SPECIFICATIONS. 3. THE OWNER SHALL PROVIDE SHOP DRAWINGS OF THE PROPOSED EQUIPMENT TO THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 4. CONTRACTOR SHALL CONFIRM ALL DIMENSIONS ON THE PROVIDED SHOP DRAWINGS ARE CONSISTENT WITH THOSE SHOWN IN THESE PLANS PRIOR TO THE START OF CONSTRUCTION. 5. DISCREPANCIES SHALL BE REPORTED TO THE OWNER AND THE ENGINEER IMMEDIATELY. 2 4 FFPT"t Element, typical, 24 sf ea 3 NA Element Overhead Winch, Indoor locations 4 1 Removable Hoist Assembly, Indoor or Outdoor locations 5 Element Removal Position 6 1 Air Scour Manifold, 304SS, Factory Mounted to Tank 7 Others influent piping, CS or equivalent, 8" Dia 8 Others Effluent piping, CS or equivalent, 8" Dia 9 Others Backwash Discharge piping, CS or equal, 6" Dla 10 Others Overflow piping, CS or equivalent, 6" Dia 11 Others Concrete Pad or Floor, Sizing & Details by Engineer ONotes: 1) All filter materials to be Type 304 Stainless Steel, PVC, Acrylic or other non- corrosive materials. All fasteners to be Type 304 Stainless Steel. 2) All piping to be Schedule 10 Stainless Steel. All connections to be ANSI standard 125 lb Flanges. All piping and piping connections to and from filter by others. 3) Nominal Assembly Weight (Dry): 3800 Lbs. Nominal Filter Operating Weight when full (Wet): 12,200 Lbs 4) NA 5) NA 6) NA 7) Contractor shall provide wiring and conduit for filter power (120VAC, 1Ph, 60Hz, 20Amp). See electrical interconnection diagram for wiring connection details. 8) Pneumatic airlines for all valves shall be provided at the factory to a common connection point near the air scour manifold inlet. Pressurized air from a local compressor or plant air source of 90 psi minimum shall be connected at the common connection point. Air line, plumbing, and conduit from compressor to the filter by others. 9) Concrete design, details, thickness, rebar, strength requirements, and substrate to be determined by engineer familiar with site and appropriate for local conditions. Installing contractor to provide appropriate anchorage for tank and pneumatic skid. 10) All dimensions, loads, elevations, and other information provide for illustrative purposes only and are not specific to any particular project or location. Not for fabrication or field erection. 11) Any stairs, walkways, railings, and details shown are for illustrative purposes only & shall be designed and provided by others. All walkways should support minimum Toads as dictated by Local construction codes. 12) Tankage dimensions and details can be found on drawing F160424-GA/Plan. 13) Hoist for element removal only, Not for moving people, or loads over people. Weight not to exceed 300 lbs. 14) Tank overflow piping not shown for clarity. Overflow can be optionally directed to effluent channel, backwash channel, or to another location as determined by others. ....... r r Drawing for general layout and sizing purposes only, NOT FOR FABRICATION ttlltlll,ur,� CORPORATE - SEAL) rp.:14; •.��, Ir— u Q Z o V— z W W LUU5 W�Q z � z~� Zz 0 Ua5 DETAILS - CLOTH MEDIA FILTER z 0 Vl DocuSign Envelope ID: 7327AB30-4FAB-4D20-99C0-685FE978C6C2 PROP. DRIVE AISLE EDGE LINE (TYP) PROP. 8" X 10" CONCENTRIC EXPANDER (FJ-FJ) SEE SHEET C6.2 FOR CONTINUATIQN PROP. EBAA FLEX -TEND (FJ-FJ) FLEXIBLE EXPANSION JOINT - vcp 8" DIP SS SEE SHEET C6.0 & C6.1 vcp vGp � k \ \ \ PROP. 28' X 52' BLOWER, PUMP, & PLANT CONTROL BUILDING , k k k \ \ \ 1 PROP. SEOUENCING BATCH REACTOR PROP. RETAINING WALL SEE GRADING PLAN FOR ADDITIONAL INFORMATION 10" DIP TO FILTER INLET SEE SHEET C6.0 & C6.1 6+54.42 22.500 HORIZ. BEND vGp _ UGp p F s FM _ iv vcp —� t?4 50' SETBACK 3 = Ucp FM US RO(JT� 27 _ GRE (60' PUBLIC ROW) NVILLF Hwy \ \\ PROPERTY BOUNDARY TYP. PROP. DRIVEWAY (SECONDARY ACCESS) PROP. EDGE OF PAVEMENT PROP.CHAIN LINK FENCE (TYP) 6+29.00 22.500 HORIZ. BEND 6+20.35 11.25° HORIZ. BEND PROP. LEVEL SPREADER SEE STORM DRAINAGE PLANS CHAPTER 5 SEE GRADING PLAN SHEET C4.0 U G PROP. STORM DRAINAGE SEE STORM DRAINAGE PLANS CHAPTER 5 50SETBACK 24" CLASS IV RCP 4+76.60 450 HORIZ. BEND F�a ~�-du r� U .. UGP �_"6` UGP ss F�, �� w � uGp — — SS F FF - PROPERTY BOUNDARY TYP. — — 1 FORCE MAIN MATERIAL • PVC - C900 SDR 18 • DUCTILE IRON PIPE - CLASS 350 ( WITH PROTECTO 401 LINER) • RESTRAINED JOINT (R.J.) DIP - CLASS 350 (WITH PROTECTO 401 LINER) EXISTING UTILITIES NOTE: EXISTING UTILITIES AS SHOWN ARE A COMPOSITE OF SURVEY, GIS, AND AS -BUILT INFORMATION. CONTRACTOR TO FIELD VERIFY ALL INVERT ELEVATIONS AND UTILITY LOCATIONS INCLUDING VERTICAL ELEVATIONS PRIOR TO STARTING CONSTRUCTION. CONTRACTOR TO NOTIFY ENGINEERAND OWNER OF ANY DISCREPANCIES. NOTES: 1. CONTRACTOR SHALL PROVIDE LOCATOR VALVE BOX WITH GREEN TRACER WIRE 2. EVERY 1,000 FEET MAXIMUM AND AT EACH BEND. LOCATOR VALVES TO READ "SEWER" WITH CONCRETE GRADE RING INSTALLED. N/F 8583-56-6509-000 CORBY DAVID J & SUSAN A DB/PG 477/730 N/F 8583-56-4212-000 CAROLINA WATER SERVICE INC. DB/PG 782/368 = 4+71.19 450 HORIZ. BEND 4+67.14 11.256VERT. BEND 3+83.17 x 3+85.491 1 22.50° HORIZ. BEND 11.25° VERT. BEND 3+76.35 45° HORIZ. O � FM FM+r�rr� FM �.r FM +�r� FM �� FM �� -�'fM �wr� FM ro�.ww FM rw.+�* FM �""� FM FM �+I FM �� FM � FM ww�rr FM �� FfaV! r�� FM FM FM wr�rs FM �r� FM____ FM+- FM �rw FM <rk -- '~++ FM �►4 UGP ---�.� UGP ----__ 1.. UGP UGP UGP -4V -- UGP --t --- UGP UGP --r-- -- -- 0GP�--- —+` ---- -- — —�- - w aN i+� ----_- UGP UGP UGP UGP --- UGP— FM FM W yy �y -GP �w^ p UGP UGP UGP UGP UGP *_ --'�." FM----�-- FM ^--^�--- W -W— W W � � © FM FM �^---- FM FM FM -- _ FM FM - -- FM F F S SS SS SS FM FM SSF�i SS .`_"„" SS --.�� F SS FM SS FM SS FM FM SS FM SS ^'�—^ � SS.� ._ �. _ SS� _ - _ � SS � � 4 � � 5S -^----.,. SS F��SSF� SS FM SEE PLAN AND PROFILE SHEETS C7.1 - C7.2 AND DETAIL SHEET C7.3 FOR ADDITIONAL INFORMATION. \\ \\ \� r -- 1 / / x r` C� '` EX. BAR SCREEN & PARSHALL FLUME f1 0+03.92 f / 45° HORIZ. BEND 1/ 1 1 x f! 1 1 A rA+05 / , 8" 3 r 1 1 / 1 r ! � f � 1 py�11 F� ! 1 ,DY\ ` ' . Fib .�?. 0+28.68 450 HORIZ. BEND 7� X EX. LIFT STATION BUILDING 1 PROP. CONC. DUMPSTER SLAB VERTICAL CURB PROP. CCNC. SIDEWALK PROP. GATE EX. STANDBY GENERATOR 8583-65-1748-000 MARIE PROPERTY BOUNDARYTYP. BEND f PROP, VERTICAL FINE / SCREEN, PROVIDED BY OWNER / FINAL DRAWING - FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 2585 2585 260' / r. � 6 2625 EX. GRADE FORCE OVER MAIN 2625 s.' EX DITCH REPAIR PROFILE AND REPLACE (TYP) ' 4/rQ. STA: 3+85.49 11.25° VERT. ELBOW ;41 - ` "rJ JJ STA: 0+64.68 IAL TRANSITION / "V .- STA: 4+67.14 -11.25° VERT. ELBOW 2580 :0 260� i' �� PIPE MATERIAL TRANSITION STA: 4+03.49 I I 2600 2620 / ", ;F., /" f> 2620 W / EX. GRADE OVER ' �� i ,' / I/�"'� F:f -=°- zi.'Azs; SZ.: ri) Sife.,=,. 18 ..%7 0)1- 7::">" t ii1;. • f•-f = •h`�. .,gyp '• l • ti • '/,-.4���t�lrtttttt�'`��``\ ',;;;4rt►ItEttti�.,;," a / �' /, 11 i - FORCE MAIN / / REPAIR EX DITCH AND REPLACE PROFILE (TYP) -- /-" i s i i f / ' EX. GRADE OVER G�f' 'I •"bf� � O FORCE MAIN . /'" ° �p1P 2575 / / �,' ira ;% /r 2575 2595 I / r .�•�•.�r . ' � `" ,•��� / ., PIPE MATERIAL TRANSITION ` 2595 / 261,E U. " 2615 � 22.50° HORIZ. ELBOW STA 3+83.17 / t -45.00° HORIZ. E STA: 4+71.19 45.0I0° HORIZ. ELBOW STA: 4+76.60 � I iii y/ r' %.ri✓ `pVG / ✓ STA: 3+40.35 45.00° HORIZ. ELBOW STA: 3+76.35 r O 10 0+05.90 8' GV y l%/; ' ! v /s f`r O✓' ,e-ri ✓/ , III IV 0) 0 STA: 44 :;�=�� PIPE MATERIAL TRANS of Z v Q4�p�Q % / -I FINAL REVIEW NOT CONSTRUCTION DRAWING -FOR PURPOSES ONLY RELEASED FOR 2570 �.c 2570 2590 ,/ 2590 2610 ri 45.00° HORIZ. ELBOW STA: 0+28.68 fi >r; s , '� - FORCE MA N MATERIAL • PVC C900 SDR 1$ 45.00° HORIZ. ELBOW STA: 0+03.92 • DUCTILE • RESTRAINED - IRON PIPE - JOINT (R.J.) CLASS 350 DIP - ( WITH CLASS 350 PROTECT° (WITH 401 LINER) PROTECT° 401 LINER) 1,4 NOTES: 1 CONTRACTOR SHALL PROVIDE LOCATOR VALVE BOX WITH GREEN ;' , f% ? TRACER WIRE EVERY 1,000 FEET MAXIMUM AND AT EACH BEND. 2. LOCATOR VALVES TO READ "SEWER" WITH CONCRETE GRADE RING ' ' f% -' PROFILE VIEW OF PROPOSED 8" FORCE MAIN INSTALLED. 2565 2565 F% �f,.• •5 I SCALE: 1" = 20' HORIZ. & 1" = 2' VERT. I 2585 2605 I 2605 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 US ROUTE 276 — GREENVILLE HWY. (60' PUBLIC ROW) r — EXISTING UTILITIES NOTE: U W CONC. SLAB FOR EXISTING UTILITIES AS SHOWN ARE A COMPOSITE OF SURVEY, GIS, AND AS -BUILT (-----__f--J~ PROP.HEAVY DUTY DUMPSTER PICK-UP INFORMATION. CONTRACTOR TO FIELD VERIFY ALL INVERT ELEVATIONS AND UTILITY LOCATIONS INCLUDING VERTICAL. ELEVATIONS PRIOR TO STARTING CONSTRUCTION. LIMITS OF SURVEY 1 CONTRACTOR TO NOTIFY ENGINEER AND OWNER OF ANY DISCREPANCIES. imJI Z "', PROPERTY BOUNDARY TYP. EX. PJW �•dIMIN•mminlinpr•Man6111.11r PROPERTY BOUNDARY TYP. `\ — `` , R fit S �_ w� — S �'••� .�. .ram .� .�. `-`�---�_r� EDGE OF EX. GRAVEL, TYP --� SS OPEN CUT EX. EX. OVERHEAD ELECTRIC �' N.,� SS DRIVEWAY i;< _1r REPLACE o O O O �x ------..y, .af�� •r` ^r/' • _ �+(.�___.�r...—_-•...^_ ~- 'yS '����JS SSA— SS JJ SS SS S JS SS �` '^`__ ti._—.� _ SS �� Ssq --`__—._—. ti.� w ��``� ----.,_ SS w� w� ---_- ____--_-__-.- _ _- -5 SS "�� rv� rs3 ___ __ S __ ____ _ _� --- w� ----_ rr y�j y� iti w�' we ~-"`-- �� w� --�- '�`~�Pk`_~- UGA__._ � ^- SS �S c. _�.,�.�- w3 ---_ v�� ------ `~-- wi ---._. wd S �� " SS SS SS` r•. � ..".: � � SS S�'____ S�__ � -____ we � ��`� _------- r+---fir !h - rH ---__ _dy--_. �` 0+28.6$ . tY� w3 we _____ w3 ----- e _._ fit, Ah M - EX. 15" STORM r� wa�-- --�___��, xwe -__1�--_--�---- din asn dsn don - -- d�r� - -,----,_._-M- ���`� ds� . ,`` 0 45 HORIZ. •� ' � BEND _-- do�l _--- dJfa --- asp dJ>ldJ€1 --j-- dJfic10/1 __ don d n ! d0(1 -----_ _�`- *'-----iVr-�--- Ak SEE INSET BELOWz'.,.•` STANDBY ~ -_----- -m..----iyaJl1 d0li - -- -dJ �4t-�--_-M---dJ(1 f?~--�--_dJi1----� d`Jfl a���ll��iGENERATOR :------rfr---- A.F.JC. �..�- ` dJ� -`��wrr d`Jf3d`Jfld`Jfld`J{1 w� '""r" N[� �■ wd 1��. wd ...l•■ d +ter YVd `�� � `�'r.�rdmma, ti ���7�aC ...,... W� Wd a.r.� iA ���� o wa,. O 1 7 REVISIONS: C or Y: SKB SKB DCS gal PLAN 1014381 CARD LI N FORCE PROP $ GV �!�Wd—w w3 ....,,�, �4� I�ii.r..�„ o —... i+Vd i� ,� a!'gym Wd wM"'"r�3 ..�„ Et w� ...... w .r.+w w�"'� ,�.._ �� ~� '1111, ' .. p. .�x / / w� +... Iwo ..+r.� ...■ w3 L w� ks.s *� ti.,� '�` � ��ii�� � � 1! ~��� o� ! w ....... �..... w� EX. SS CLEANOUT (TO REMAIN) ate. !END RJ CLASS 350 DIP LATERAL TO BE CAPPED BEGIN RJ CLASS 350 DIP 3+76.35 • � , •f8" GV � � STA: 0+64.68 ADJACENT TO CLEANOUT STA: 3+40.35 45 HORIZ. BEND EDGE OF EX. GRAVEL, TYP EX. LFIT STATION 1�.j! ►� 4 � TEE TO EX. +� ` - . nrs ! LIMITS OF SURVEY 1 3+85.49 C �, 0+03.92 . 3+83.17 � 11.25° VERT. BENDS ;-..45° HORIZ. BEND 22.50° HORIZ. BEND u 1 _ IBEG R3-31P `'0. X -_.� x x �._ X rx~ : x �r „ .0 PROP $" 45° LATERAL. PROP. FORCE -.�i END RJ CLASS 350 DIP q STA: 4+03.49 x� ._� r"z7 0 ' EX. \ 50' SETBACK CONCRETE PROP. 8" FORCE DRIVEWAY \ MAIN, TYP Z 0 l'T a BEFORE YOU DIG! \ ti CALL 1-800-632-4949 8"0 EX. FM \ : 350 O N.C. ONE -CALL CENTER ti IT'S THE LAW! �6�1A mmnammm mmfam RI ill Ott RR �ar m EMUS m lib gEl t / 'BEGIN RJ CLASS 350 DIP / u- Gv 1 NOTE: STA: s 6srilui PROP 8" t / 4 CONTRACTOR TO LOCATE S 03 u EX. FORCEMAIN PRIOR TO \ co : TIE TO EXISTING m BEGIN RJ DIP START OF CONSTRUCTION a / �� B 4+67.14 \ 11.25° VERT. �• W BEND rn w 1 LIFT STATION 1.19 Q a 4 WALL + I \ 45° HORIZ. BEND cca r cn Z 1,_-r .._—_......�..�-- 8tii 1 IS - -r. PROPERTY BOUNDARY TYP. �w a= �: U 21 PROP 8" 45° ° t LATERAL PROP $ 22 a \ C Ia 1 HORIZ. BEND R q a f a M --�, a 4+76.60 Iiim m m®simnammummummmnm� � ailmwammum� `\ 45° HORIZ. BEND INSET PROP. DRIVEWAY SCALE: 1" = 5' \ {SECONDARY ACCESS)11111171111111111111r1111111.11111111111.1111111 \ 10' 0' 10' 20' 40' PROP. EDGE OF PAVEMENT DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 2635 2635 STA: 7+94.82 BUILDING EXTERIOR WALL I._._._ _I........__. _L...... EX. GRADE OVER FORCE MAIN \ \ \ EX. FORCE GRADE MAIN OVER f \ 1 /� ` '� / _._.._ PROP 8" X 10" EXPANDER CONCENTRIC (FJ-FJ) STA: 6+54.42 22.50° VERT. ELBOW 1- IL-- I 7 / — PROP SEE SBR CONTINUATION 10" DIP FLANGED VACFLUSH CONNECTIONS PIPING PLAN FOR 2630 f GRADE r 2630 OVEPROP. R FORCE MAIN PROP. EBAA FLEXIBLE FLEX -TEND° EXPANSION (FJ-FJ) JOINT C) T-itlf'N " ------- 1:-. ;''._:* #1111. ii-dig '''`/ifrfrrliinitil�\```` 4......t f�/llfll llNll�0\i\`` zz 1�� 10" DIP I Q z f 024"CLASS cc IVRCD { STA: 5+84.35 F. MATERIAL TRANSITION f i J T a1.69' 2625 IU„ 22.50° HORIZ. ELBOW STA: 7+08.60 z 22.50° HORIZ. ELBOW STA: 7+54.49 22.50° HORIZ. ELBOV STA: 7+7147 • PROP. 6" DIP 2625 • • • MATCHLINE STA 5+00 SEE SHEE STA: 6+20.35 22.50° HORIZ. ELBOW STA: 6+29.00 • • PROP. 6" DIP \.... O m 6+87.51 10" DIP STA: PROP. 7+80.82 6" DIP STA: 5+11.1 PIPE MATERIAL TRANSITIC 11.25° HORIZ. El PROP. 8' DIP PROP. WATER LINE 9 901 C,,',�' / PROP. LATERAL 6" DIP , fr /�y, %/� 2620 FINAL REVIEW NOT RELEASED DRAWING -FOR PURPOSES ONLY FOR /.dJ 8" RJ DIP PROFILE VIEW OF PROPOSED 8" FORCE MAIN 2615 SCALE: 1" : 20' HORIZ. & 1" = 2' VERT. 2615 5+00 5+50 6+00 6+50 7+00 7+50 8+00 8+50 9+00 9+50 10+00 10+50 V W U PROP. STORM DRAINAGE SEE STORM DRAINAGE PLANS CHAPTER 5 FORCE MAIN MATERIAL PROP. 8" FORCE • PVC - C900 SDR 18 MAIN, TYP • DUCTILE IRON PIPE - CLASS 350 ( WITH PROTECTO 401 LINER) • RESTRAINED JOINT (R.J.) DIP - CLASS 350 (WITH PROTECTO 401 LINER) 1 LL PROP. LEVEL SPREADER z SEE STORM DRAINAGE PLANS CHAPTER 5 o - .. SEE GRADING PLAN SHEET C4.0 Lt„- W Uce Q '::�;s'+l 1. CONTRACTOR SHALL PROVIDE LOCATOR VALVE BOX WITH GREEN z �*.:.4 :::.,':.... TRACER WIRE �'- •••••• :-- .v4 EVERY 1,000 FEET MAXIMUM AND AT EACH BEND. • •+• 2. LOCATOR VALVES TO READ "SEWER" WITH CONCRETE GRADE RING "� 0. z z W w ' ••'• �,:•-,. " v FES-10 •• INSTALLED. W U > Z 4,4-••�':; . O ��.�:`: u. cq. BEGIN RJ CLASS 350 DIP t- Li 0 116 STA: 6+06.88 �" x x x EXISTING UTILITIES NOTE: _"" /� tu IN m ". ... x 6+54.42 � � + EXISTING UTILITIES AS SHOWN AREA COMPOSITE OF SURVEY, GIS, AND AS -BUILT 22.50° INFORMATION. W 1'I I ' 7 tu HORIZ. BEND f u) W in ate- o �� x X `" ` x 6+87.51 CONTRACTOR TO FIELD VERIFY ALL INVERT ELEVATIONS AND UTILITY LOCATIONS INCLUDING o " VERTICAL ELEVATIONS PRIOR TO STARTING CONSTRUCTION. 24"CLASS IV RCP W� _ cliy ... "� 45° HORIZ. BEND r ~-� '�W� CONTRACTOR TO NOTIFY ENGINEER AND OWNER OF ANY DISCREPANCIES. REVISIONS: COt PLAN CAROLN FORCE \ y 6+20.35 r 11.25° HORI. BEND 1 C t..! t7 . 2 ° 6+29 00 O \�v�i�� o0 PROP. DRIVEWAY 22.50 HORIZ. BEND :.° ,... .: � �o`� O PROP. 8" DIP SS SEE UTILITY PLANS (SECONDARY ACCESS) EDGE OF PROP. t�, 7+08.60 22.50° HORIZ. BEND �o 8,� SS SSS �..- �o !1 GRAVEL ACCESS ' t._ s$ �••`-`� '� -iii !, S W - ROAD, TYP c - r,,.w—^ PROP. SBR DRAIN 0 +'••"-`' W �� or PROP. SBR EFFLUENT Pli 11 N TO FILTER BUILDING CD 10" DIP, TYP SSMH-2[ 7 t \.C. BEFORE YOU DIG! CALL CALL 9-800-632-4949 N‘ ATS THELLAWNTER si `\cn \ CO \ 7+54.49 PROP. 2" WTR 22.50° HORIZ. BEND LINE \ i111 tjySt.tyyyy /> 7+71.37 tyyySly4iiy:\\1:"22.50° HORIZ. BEND 11�yy.ylll.‘�. / i, j PROP. EBAA FLEX TEND° (FJ-FJ) \ “'tId►t. ��� • ;'+ :v FLEXIBLE EXPANSION JOINT )4itiy��`\`� �`�?������• + PROP. 8" X 10" CONCENTRIC ` PROPERTY BOUNDARY iYP. \ � ?�'••�•y� '�'`• / \ EXPANDER (FJ-FJ) A" ...// �. �•.� PROP. 10V' DIP FLANGED CONNECTIONS11.17/11.1j11111111.1.1111.1111 \ ! ti► i1. ' SEE SHEET C6.2 FOR CONTINUATION LIMITS OF SURVEY *� � /I� I0' 0' 10' 20' 40' `: •/ u a .. - - fly DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 r C7.3 TRENCH WIDTH + 4-FT WIDTH VARIES 6"MIN DRIVEWAY WDTH VARIES (MATCH EXISTING) T~ t TRENCH WIDTH 4.44.4.44•4•444 4�444444444444Q'►404�4@►44 4®444444 ��44,�"I04444. 40) 4 �� k 4'4048.4®fie♦. 4044414 4444444 4��P444404 4444�►4044444 4434�44�484'�444�4�444�4� '�44e�'44444'�'4444444��s�: 41044110 4,0444444a • a • 4 •Q REPLACE DRIVEWAY SURFACE TO EDGE OF EX. GRAVEL ACCESS ROAD 4 — 8" FORCEMAIN EXISTING EDGE OF PAVEMENT PLAN REPLACED BASE MATERIAL OVER TRENCH SHALL BE TWICE THE THICKNESS OF ORIGINAL BASE OR 12" MINIMUM, WHICHEVER IS GREATER PRIVATE DRIVEWAY OPEN CUT DETAIL PLAN / SECTION PIPE DEPTH VARIES SUBSEQUEN BACKFILL, SEE NOTE 6 T EMBEDMENT, SEE NOTE 4 * 6" MIN Bc (NP) LIFT TRENCH BOX IN STEPS AS BACKFILL IS PLACED IN LIFTS VARIES ' MIN. (TYP) * BEDDING 0 PIPE C/L 1 STABLE SUBGRADE SLOPING SIDES ALTERNATIVE CONSTRUCTION (TYP) NOTES: 1. ALL EXCAVATIONS FOR PIPE LAYING (FORCEMAIN, WATER MAIN AND GRAVITY SEWER) SHALL COMPLY WITH THE CAROLINA WATER SERVICE INC. OF NC STANDARD SPECIFICATIONS AND DETAILS 2. PIPE SHALL HAVE A MINIMUM COVER OF 36". MINIMUM TRENCH WIDTH AT THE TOP OF THE PIPE SHALL BE AT LEAST 18 INCHES GREATER THAN THE OUTSIDE DIAMETER OF THE PIPE. WHERE EXCAVATION IS IN ROCK, THE ROCK SHALL BE REMOVED TO A DEPTH OF AT LEAST 6 INCHES BELOW GRADE AND SHALL BE BACKFILLED WITH SUITABLE MATERIAL WET TRENCHES SHALL BE STABILIZED WITH #78M STONE OR WITH A BASE LAYER OF #57 STONE. 3. THE BEDDING (6" MINIMUM) AND EMBEDMENT MATERIALS SHALL BE PER ASTM D2321. THE EMBEDMENT MATERIAL SHALL BE INSTALLED FROM TRENCH WALL TO TRENCH WALL AND FROM THE INVERT TO A MINIMUM OF 6" ABOVE THE CROWN OF THE PIPE. 4. THE BEDDING AND EMBEDMENT MATERIALS SHALL BE COMPACTED TO A MINIMUM OF 90% STANDARD PROCTOR DENSITY FOR CLASS I AND II MATERIALS. BEDDING AND EMBEDMENT MATERIALS CLASSIFICATIONS SHALL BE AS DEFINED BY THE CAROLINA WATER SERVICE INC. OF NC WRITTEN SPECIFICATIONS FOR WATER DISTRIBUTION & WASTEWATER COLLECTION 5. SHORING AND BRACING OF PITS, TRENCHES AND OTHER EXCAVATIONS SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE APPLICABLE DEPARTMENT OF TRANSPORTATION AND THE FEDERAL OCCUPATIONAL SAFETY AND HEALTH ACT. 6. THE EXCAVATION SHALL BE MADE TO THE ELEVATIONS, GRADES, AND LINES SHOWN ON THE CONSTRUCTION PLANS. UNLESS OTHERWISE APPROVED BY THE ENGINEER. THE TRENCH BOTTOM SHALL BE EXCAVATED SLIGHTLY ABOVE GRADE AND CUT DOWN TO THE PIPE GRADE BY HAND IN THE FINE GRADING OPERATION. THE TRENCH BOTTOM SHALL BE TRUE AND EVEN WITH BELL HOLES AT EACH JOINT TO PROVIDE THE BARREL OF THE PIPE WITH SOIL AND/OR GRANULAR BEDDING (AS APPLICABLE) SUPPORT FOR ITS FULL LENGTH. 7. SUBSEQUENT BACKFILL MATERIAL SHALL BE FREE FROM TOPSOIL, PEAT, WOOD, ROOTS, BARK, DEBRIS, LUMBER, GARBAGE, RUBBISH OR OTHER EXTRANEOUS MATERIAL. THE MAX ROCK SIZE SHALL NOT EXCEED 4 INCHES. MATERIAL SHALL HAVE A PLASTICITY INDEX LESS THAN 25 PERCENT AND THE ROCK TO SOIL RATIO SHALL NOT EXCEED ONE PART ROCK TO THREE PARTS SOIL. BACKFILL SHALL BE PLACED IN LOOSE LIFTS WITH A MAX THICKNESS OF 8 INCHES AND COMPACTED TO 95 PERCENT (AASHO T99). FORCE MAIN TRENCH C7.3 SECTION NTS 6" MIN TRENCH WIDTH + 4-FT WIDTH VARIES rdle, A r A REPLACE EXISTING DRIVEWAY SURFACE (MATCH EXISTING MATERIAL AND THICKNESS) 9" MIN -0-- TRENCH WIDTH --00- SECTION REPLACE DRIVEWAY SURFACE TO EDGE OF EX. GRAVEL ACCESS DRIVE ORIGINAL BASE MATERIAL REPLACED BASE MATERIAL OVER TRENCH SHALL BE TWICE THE THICKNESS OF ORIGINAL BASE OR 12" MINIMUM, WHICHEVER IS GREATER 8" FORCEMAIN NTS v. CORPORATE 1.,-SEAL1 g !llrrltlt\\ I I.1111 W0 a 't( 1/1/ 4! ;0 I 0 ", `. A 6988 ,,,,%,,`.NGrNER. 1;,/11/llltiO NN 9/19/2017 h z0 u z V) u Z 0 N_ cL co 0 0°r° Le) vq2 11! � o opm0OQ °'ZzIS2i- -.0 00.0000'in0_ DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 8 7 6 5 8" DIGESTER WAS - 4 3 2 1 DECANTER - 8" DIGESTER JET HEADER - 10" SBR JET HEADER - 10" ID/SC MANIFOLD -� JET HEADER N STD: BORDER-0106-24X36D1 INTL REF: 07/14/2017 - 12:47 PMI JET HEADER D/103 rm._ B/102 r A/102 8" DIGESTER SUCTION 10" SBR JET HEADER 10" ID/SC MANIFOLD 6" AIR CONNECTIONS D2 DIFFUSERS PRELIMINARY DIMENSIONS IN INCHES UNLESS SPECIFIED DO RT AAFT CO TR PU LO TOLERANCES UNI OTHERWISE SPECIFIED TWO (2) PLACE DEC. *.06 THREE (3) PLACE DEC. ±.005 ANGULAR ±.50. DT TO BE USED FOR CONSTRUCTION PURPOSES • RE MA AN TH Wll NO AC STRUCTURAL DIMENSIONS 1/I6 MACHINED 250/ SURFACES �/ I I BAR = 1" AT PLOT SCALE REV DESCRIPTION DATE OWN CHKD APVD ECN CO COMPANY CONFIDENTIAL CUMENT AND ALL INFORMATION CONTAINED HEREIN E THE PROPERTY OF EVOQUA AND/OR ITS 1UATES. THE DESIGN CONCEPTS AND INFORMATION NTAINED HEREIN ARE PROPRIETARY TO EVOQUA D ARE SUBMITTED IN CONFIDENCE. THEY ARE NOT ANSFERABLE AND MUST BE USED ONLY FOR THE RPOSE FOR WHICH THE DOCUMENT IS EXPRESSLY AHED. THEY MUST NOT BE DISCLOSED, PRODUCED, LOANED OR USED IN ANY OTHER NNER WITHOUT THE EXPRESS WRITTEN CONSENT EVOQUA. IN NO EVENT SWILL THEY BE USED IN Y MANNER DETRIMENTAL TO THE INTEREST OF 3QUA. ALL PATENT RIGHTS ARE RESERVED. UPON E DEMAND OF EVOQUA, THIS DOCUMENT, ALONG fH ALL COPIES AND EXTRACTS, AND ALL RELATED TES AND ANALYSES. MUST BE RETURNED TO DQUA OR DESTROYED, AS INSTRUCTED BY EVOQUA. CEPTANCE OF THE DELIVERY OF THIS DOCUMENT NSTITUTES AGREEMENT TO THESE TERMS. EQUIPMENT GENERAL ARRANGEMENT DRAWING NOTES: 1. DRAWING NOT TO BE USED FOR CONSTRUCTION 2. EQUIPMENT TO BE SUPPLIED BY THE OWNER OR SBR MANUFACTURER SHALL BE INSTALLED BY THE CONTRACTOR ACCORDING TO MANUFACTURER'S SPECIFICATIONS. 3. THE OWNER SHALL PROVIDE SHOP DRAWINGS OF THE PROPOSED EQUIPMENT TO THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 4. CONTRACTOR SHALL CONFIRM ALL DIMENSIONS ON THE OWNER PROVIDED SHOP DRAWINGS ARE CONSISTENT WITH THOSE SHOWN IN CONSTRUCTION DOCUMENTS PRIOR TO THE START OF CONSTRUCTION. 5. DISCREPANCIES SHALL BE REPORTED TO THE OWNER AND THE ENGINEER IMMEDIATELY. DESIGNER cc DATE 7/12/17 CHECKER DATE TITLE OMINIPAC SEQUENCING BATCH REACTOR PLAN VIEW ENGINEER DATE CLIENT CONNESTEE FALLS, NC MANAGER DATE FILE: evoQuA WATER TECHNOLOGIES WATER TECHNOLOGIES WAUKESHA, WI 262-547-0141 SCALE: 1/4"=V-0" PROJECT CODE SBR DRAWING 45954-101 SHEET 1 OF 1 DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 8 7 6 5 4 3 2 1 TWL EL 22.5' WL EL 15.33' DECANTER REST DECA\ TES 10" ID/SC MANIFOLD SECTO\ DECANTER ROTATED FOR CLARITY VIEW 6" JET HEADER AIR PIPE 10" JET HEADER FLUID PIPE—,,,,,,c • • •.4 r. .4• ay '; • w.4• ,21•a. /• • 4. .1 .4+ .d ,,,• a. "�' . 'a y• 4. •4•,•,a ,a. ••.4• 'd, • ,'•'• ,'a•a. • 1 •f. , ,.y' .• a '�••f•`4. • •'f .•. 1'• ..' S CT1ON 3/1O1 PRELIMINARY NOT TO BE USED FOR CONSTRUCTION PURPOSES STD: BORDER-0106-24X36D1 INTL REF: 07/14/2017 - 12:49 PM 3' --4" 1'-0„ 10" JET HEADER FLUID PIPE 6" JET HEADER AIR PIPE 8" DIGESTER SUCTION h _' •ate • a • 1 d •'s • I . . • a. d �Z r • • •'•, 4 y• y. •a. •ad a•'4•'1 'f••• • R •a�d a• as y• •:. a • • • j ' • a .jd, .. •. •A •: .: a .1 . •:. �• . •a 4 ; • S' • , d ar .* 14. . R i •Z 1; I.d SECTIO 4 ♦ q' 4. • ..a•. S. ..4 •1.' y A • \ A/101 a.• • EQUIPMENT GENERAL ARRANGEMENT DRAWING NOTES: 1. DRAWING NOT TO BE USED FOR CONSTRUCTION 2. EQUIPMENT TO BE SUPPLIED BY THE OWNER OR SBR MANUFACTURER SHALL BE INSTALLED BY THE CONTRACTOR ACCORDING TO MANUFACTURER'S SPECIFICATIONS. 3. THE OWNER SHALL PROVIDE SHOP DRAWINGS OF THE PROPOSED EQUIPMENT TO THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 4. CONTRACTOR SHALL CONFIRM ALL DIMENSIONS ON THE OWNER PROVIDED SHOP DRAWINGS ARE CONSISTENT WITH THOSE SHOWN IN CONSTRUCTION DOCUMENTS PRIOR TO THE START OF CONSTRUCTION. 5. DISCREPANCIES SHALL BE REPORTED TO THE OWNER AND THE ENGINEER IMMEDIATELY. DIMENSIONS IN INCHES UNLESS SPECIFIED TOLERANCES UNLESS OTHERWISE SPECIFIED TWO (2) PLACE DEC. t.06 THREE (3) PLACE DEC. ±.O05 ANGULAR t.50' STRUCTURAL DIMENSIONS MACHINED SURFACES A. 1/16 2S0/ BAR = 1" AT PLOT SCALE REV DESCRIPTION DATE DWN CHKD APVD ECN COMPANY CONFIDENTIAL DOCUMENT AND ALL INFORMATION CONTAINED HEREIN ARE THE PROPERTY OF EVOQUA AND/OR ITS AFFILIATES. THE DESIGN CONCEPTS AND INFORMATION CONTAINED HEREIN ARE PROPRIETARY TO EVOQUA AND ARE SUBMITTED IN CONFIDENCE. THEY ARE NOT TRANSFERABLE AND MUST BE USED ONLY FOR THE PURPOSE FOR WHICH THE DOCUMENT IS EXPRESSLY LOANED. THEY MUST NOT BE DISCLOSED, REPRODUCED, LOANED OR USED IN ANY OTHER MANNER WITHOUT THE EXPRESS WRITTEN CONSENT OF EVOQUA. IN NO EVENT SHALL THEY BE USED IN ANY MANNER DETRIMENTAL TO THE INTEREST OF EVOQUA. ALL PATENT RIGHTS ARE RESERVED. UPON THE DEMAND OF EVOQUA, THIS DOCUMENT, ALONG WITH ALL COPIES AND EXTRACTS, AND ALL RELATED NOTES AND ANALYSES, MUST BE RETURNED TO EVOQUA OR DESTROYED, AS INSTRUCTED BY EVOQUA. ACCEPTANCE OF THE DELNER( OF THIS DOCUMENT CONSTITUTES AGREEMENT TO THESE TERMS. DESIGNER CC DATE 7/12/17 CHECKER DATE TITLE OMINIPAC SEQUENCING. BATCH REACTOR SECTION VIEWS ENGINEER DATE CLIENT CONNESTEE FALLS, NC MANAGER DATE FILE: P,VOQUA WATER TECHNOLOGIES WAUKESHA, WI WATER TECHNOLOGIES 262---547--0141 SCALE: 1/2: PROJECT CODE SBR DRAWING 45954-102 SHEET OF DocuSign Envelope ID: 7327AB30-4FAB-4D2D-99C0-685FE978C6C2 8 7 6 5 4 3 2 1 3'-4" (REF) 1.4 C7- ! 10" JET HEADER FLUID PIPE 6" JET HEADER AIR PIPE r W,a - AA r` 3'-4" (REF) • �. , a : 4• a y , • . , �• . . 'A . . •'.w. a 4 •' •••4''• r • 'fi: .i • 4, r ew ._ �: .� Y •11• • 4• .• 1 2'-6" (HOLD) 6" HOLD STD: BORDER-0106-24X36D1 /. 4 w • • INTL REF: S = CTI O 07/14/2017 - 12:50 PM 4 SECTIO\ � PRELIMINARY NOT TO BE USED FOR CONSTRUCTION PURPOSES •• s Y 4 • / ♦. • 1C1 AIR PIPING (BY OTHERS) , a•; r 4 • w 4 Y ,. �• s ', r a A SECTIO EQUIPMENT GENERAL ARRANGEMENT DRAWING NOTES: 1. DRAWING NOT TO BE USED FOR CONSTRUCTION 2. EQUIPMENT TO BE SUPPLIED BY THE OWNER OR SBR MANUFACTURER SHALL BE INSTALLED BY THE CONTRACTOR ACCORDING TO MANUFACTURER'S SPECIFICATIONS. 3. THE OWNER SHALL PROVIDE SHOP DRAWINGS OF THE PROPOSED EQUIPMENT TO THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 4. CONTRACTOR SHALL CONFIRM ALL DIMENSIONS ON THE OWNER PROVIDED SHOP DRAWINGS ARE CONSISTENT WITH THOSE SHOWN IN CONSTRUCTION DOCUMENTS PRIOR TO THE START OF CONSTRUCTION. 5. DISCREPANCIES SHALL BE REPORTED TO THE OWNER AND THE ENGINEER IMMEDIATELY. 1 Di DIMENSIONS IN INCHES UNLESS SPECIFIED TOLERANCES UNLESS OTHERWISE SPECIFIED TWO (2) PLACE DEC. ±.06 THREE (3) PLACE DEC. ±.005 ANGULAR t.50' STRUCTURAL DIMENSIONS ± 1/16 MACHINED 2 / SURFACES �/ BAR = 1" AT PLOT SCALE REV DESCRIPTION DATE DWN CHKD APVD ECN COMPANY CONFIDENTIAL DOCUMENT AND ALL INFORMATION CONTAINED HEREIN ARE THE PROPERTY OF EVOQUA AND/OR ITS AFFIUATES. THE DESIGN CONCEPTS AND INFORMATION CONTAINED HEREIN ARE PROPRIETARY TO EVOQUA AND ARE SUBMITTED IN CONFIDENCE. THEY ARE NOT TRANSFERABLE AND MUST BE USED ONLY FOR THE PURPOSE FOR WHICH THE DOCUMENT IS EXPRESSLY LOANED. THEY MUST NOT BE DISCLOSED, REPRODUCED, LOANED OR USED IN ANY OTHER MANNER Wf>•IOUT THE EXPRESS WRITTEN CONSENT OF EVOQUA. IN NO EVENT SHALL THEY BE USED IN ANY MANNER DETRIMENTAL TO THE INTEREST OF EVOQUA. ALL PATENT RIGHTS ARE RESERVED. UPON THE DEMAND OF EVOQUA, THIS DOCUMENT, ALONG WITH ALL COPIES AND EXTRACTS, AND ALL RELATED NOTES AND ANALYSES, MUST BE RETURNED TO EVOQUA OR DESTROYED, AS INSTRUCTED BY EVOQUA. ACCEPTANCE OF THE DELNERY OF THIS DOCUMENT CONSTITUTES AGREEMENT TO THESE TERMS. DESIGNER cc CHECKER ENGINEER MANAGER FILE: DATE 7/12/17, DATE TITLE OMINIPAC SEQUENCING BATCH REACTOR SECTION VIEWS DATE DATE CLIENT CONNESTEE FALLS, NC 1 eVOQUA WA WATER TECHNOLOGIES WI WATER TECHNOLOGIES 262-547-0141 SCALE: 1/2: = 1 '-0" PROJECT CODE SBR DRAWING 45954-103 SHEET 1 OF 1 REV A DocuSign Envelope ID:7327AB30-4FAB-4D2D-99C0-685FE978C6C2 ROY COOPER e 1:11 :- _ - Gavcroor 0 di r. J MICHAEL S.REGAIN .�,•^ . Seerlerory �` rra„ '� LINDA CULPEPPER NORTH CAROLINA ' Director &nviram:aemid Quality February 03, 2020 . Carolina Water Service Inc. of North Carolina Attn: Tony Konsul, Dir. of Operations. PO Box 240908 Charlotte, NC 28224-0908 Subject: Permit Renewal. Application No. NC0024295 • Connestee Falls.WWTP #1 Transylvania County Dear Applicant: The Water Quality Permitting Section acknowledges the February 3, 2020 receipt of your permit renewal application and supporting documentation. Your application will be assigned to.a permit writer within the Section's NPDES WW permitting branch. Per G.S. 150B-3 your current permit does not expire until permit decision on the application is made. Continuation of the current permit is contingent on timely and sufficient application for renewal of the current permit.The permit writer will contact you if additional information is required to complete your permit renewal. Please respond in a timely manner to requests for additional information necessary to allow a complete review of the application and renewal of the permit. Information regarding the status of your renewal application can be found online using the Department,of Environmental Quality's Environmental Application Tracker at: : hops://deq.nc.gov/permits-regulations/permit=guidance/environmental-application-tracker If you have any additional questions about the permit, please contact the primary reviewer of the application using the links available within the Application Tracker.: Sin erely, lam' Wren Thedford Administrative Assistant Water Quality Permitting Section cc: Central Files w/application ec: WQPS Laserfiche.File w/application ,,,, North_Carotias Departrceittof.Erviror Lrr rnermtfi1Qual"ay I :DivabnofWaterResoes DE� 41..avi.te r 10fft 1.2{YSO U.S.4oh fir,vsr?1 Sibapm Cs aaps;.North ioliriaa 23775 o.,s,..sati,«�r,d.i4 82$.295145DO . . DocuSign Envelope ID:7327AB30-4FAB-4D2D-99C0-685FE978C6C2 RECEIVED FEB 0 3 2020 C u Water C b4 Ie .aF " of North CarolinaTM January 30, 2020 Mr. Wren Thedford NC DENR Division of Water Quality Point Source Branch 1617 Mail Service Center Raleigh NC 27699-1617 Re: Connestee Falls WWTP# 1 NPDES NC0024295 Renewal Request Dear Mr. Thedford, Please find enclosed, application and attachments and consider this letter as our official request to renew the NPDES permit for the facility referenced above. Please note that the new facility was constructed under the A to C No. 024295A02. If you should have any questions or need any additional information, please do not hesitate to call me at 704-319-0523 or by email at Tony.Konsul@carolinawaterservice.com Thank you in advance for your attention. Sincerely sul Director of Operations •4944 Parkway Plaza Blvd.Ste 375 • Charlotte, North Carolina 28217 • 800-525-7990 DocuSign Envelope ID:7327AB30-4FAB-4D2D-99C0-685FE978C6C2 NPDES APPLICATION - FORM D For privately-owned treatment systems treating 100% domestic wastewaters <1.0 MGD Mail the complete application to: N. C. DENR / Division of Water Quality / NPDES Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 NPDES Permit INC0024295 If you are completing this form in computer use the TAB.key or the up - down arrows to move from one field to the next. To check the boxes, click your mouse on top of the box. Otherwise,please print or type. 1. Contact Information: Owner Name Carolina Water Service, Inc of NC Facility Name Connestee Falls - WWTP Mailing Address P.O. Box 240908 City Charlotte State / Zip Code NC, 28224 Telephone Number (704)319-0523 Fax Number (704)525-8174 e-mail Address Tony.Konsul carolinawaterservicenc.com 2. Location of facility producing discharge: Check here if same address as above Street Address or State Road 183 Connestee Utilities Drive City Brevard State / Zip Code NC 28712 County Transylvania 3. Operator Information: Name of the firm, public organization or other entity that operates the facility. (Note that this is not referring to the Operator in Responsible Charge or ORC) Name . . Carolina Water Service, Inc. Of North Carolina Mailing Address ' PO Box 240908 City Charlotte State / Zip Code NC, 28224 Telephone Number 704-525-7990 Fax Number 704-525-8174 e-mail Address Tony.Korisulacarolinawaterservicenc.com 1 of 3 FomrD 11/12 DocuSign Envelope ID:7327AB30-4FAB-4D2D-99C0-685FE978C6C2 NPDES APPLICATION - FORM D For privately-owned treatment systems treating 100% domestic wastewaters <1.0 MGD 10. Flow Information: Treatment Plant Design flow 0.360 MGD Annual Average daily flow 0.220 MGD (for the previous 3 years) Maximum daily flow 0.521 MGD (for the previous 3 years) 11. Is this facility located on Indian country? ❑ Yes ® No 12. Effluent Data NEW APPLICANTS:Provide data for the parameters listed. Fecal Coliform, Temperature and pH shall be grab samples,for all other parameters 24-hour composite sampling shall be used. If more than one analysis is reported, report daily maximum and monthly average. If only one analysis is reported, report as daily maximum. RENEWAL APPLICANTS: Provide the highest single reading (Daily Maximum) and Monthly Average over the past 36 months for parameters currently in your permit. Mark other parameters "N/A". Parameter Daily Monthly Units of Maximum Average Measurement Biochemical Oxygen Demand (BOD5) 30.1 3.5 Mg/L Fecal Coliform 600 3.8 # 100/ML Total Suspended Solids 32.2 3.6 Mg/L Temperature (Summer) 22.0 17.7 Celsius Temperature (Winter) 16.8 11.4 Celsius pH 7.3 6.5 S.U. 13. List all permits, construction approvals and/or applications: Type Permit Number Type Permit Number Hazardous Waste (RCRA) NESHAPS (CAA) UIC (SDWA) Ocean Dumping(MPRSA) NPDES NC0024295 Dredge or fill (Section 404 or CWA) PSD (CAA) Other WQCS00219 Non-attainment program (CAA) 14. APPLICANT CERTIFICATION I certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, complete,and accurate. t 'i \ Director of Operations Printed name of Person Signin Title re—OZd Signature f Appl Date o ro ina General Statute 143-215.6 (b)(2) states: Any person who knowingly makes any false statement representation, or certification in any application, record, report, plan, or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article,shall be guilty of a misdemeanor punishable by a fine not to exceed$25,000,or by imprisonment not to exceed six months,or by both. (18 U.S.C.Section 1001 provides a punishment by a fine of not more than$25,000 or imprisonment not more than 5 years,or both,for a similar offense.) 3 of 3 Form-D 11/12 DocuSign Envelope ID:7327AB30-4FAB-4D2D-99C0-685FE978C6C2 • NPDES APPLICATION - FORM D For privately-owned treatment systems treating 100% domestic wastewaters <1.0 MGD 4. Description of wastewater: Facility Generating Wastewater(check all that apply): Industrial ❑ Number of Employees Commercial ❑ Number of Employees Residential ® Number of Homes 1033 School ❑ Number of Students/Staff Other ❑ Explain: Describe the source(s) of wastewater (example: subdivision, mobile home park, shopping centers, restaurants, etc.): Connestee Falls subdivision-gated community residential 1033 x 2.5 = 2583 population Number of persons served: 2583 5. Type of collection system ® Separate (sanitary sewer only) ❑ Combined (storm sewer and sanitary sewer) 6. Outfall Information: Number of separate discharge points 1 Outfall Identification number(s) 001 Is the outfall equipped with a diffuser? ❑ Yes ® No 7. Name of receiving stream(s) (NEW applicants:Provide a map showing the exact location of each outfall): French Broad River 8. Frequency of Discharge: Continuous ❑ Intermittent If intermittent: Days per week discharge occurs: Duration: 9. Describe the treatment system List all installed components, including capacities, provide design removal for BOD, TSS, nitrogen and phosphorus. If the space provided is not sufficient, attach the description of the treatment system in a separate sheet of paper. New 0.360MGD SBR which includes the following components, vertical fine screen and auger with a capacity to handle 1.15 MGD flow, Influent lift station with (2) 625gpm pumps and VFD controls, (2) 9,410 gallon SBR basins, (1) 101,620 gallon post -EQ basin, (1)126,970 gallon digester. Three 499- SCFM SBR blowers, (1) 144SCFM post aeration blower (1) 240 SCFM digester blower, (2) 1831 gpm SBR pumps, (1) 1098 gpm digester pump, (2) fixed 384 square ft plate cloth media filters with each containing (4) cloth filtering elements and air scour. Components also include (2) UV disinfection units with each unit capacity rated for 0.90MGD flow with channel, automatic controls and monitoring. Effluent flow meter and channel. Emergency back-up generator and controls. 2 of 3 Form-D 11/12 DocuSign Envelope ID:7327AB30-4FAB-4D2D-99C0-685FE978C6C2 :: Cr* hn Watrl I° ater Service of North CarolinaTM January 30, 2020 Mr. Wren Thedford NC DENR Division of Water Quality Point Source Branch 1617 Mail Service Center Raleigh NC 27699-1617 Re: Connestee Falls WWTP NPDES NC0024295 Sludge Management Plan Dear Mr. Thedford, As sludge and other solids are generated at this facility, they are periodically removed by a contractor, Mikes Septic Tank Services. Other contractors are available should Mikes Septic be unable to meet a schedule. Mikes Septic Tank Services 80 Harold Sluder Road Alexander NC, 28071 If you should have any questions or need any additional information, please do not hesitate to call me at 704-319 -0523 or by email at Tony.Konsul@carolinawaterservicenc.com Thank you in advance for your attention. Sincerely onsul Director of Operations •4944 Parkway Plaza Blvd.Ste 375 • Charlotte, North Carolina 28217 • 800-525-7990 DocuSign Envelope ID:7327AB30-4FAB-4D2D-99C0-685FE978C6C2 Permit N C0024295 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF WATER RESOURCES PERMIT TO DISCHARGE WASTEWATER UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provisions of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act,as amended, Transylvania Utilities, Inc. is hereby authorized to discharge wastewater from a facility located at the Connestee Falls WWTP No. 1 5999 Greenville Highway Brevard,NC Transylvania County to receiving waters designated as the French Broad River in the French Broad River Basin in accordance with effluent limits, monitoring requirements, and other applicable conditions set forth in Parts I, II,III and IV hereof. This permit shall become effective March 1, 2016. This permit and authorization to discharge shall expire at midnight on September 30, 2020. Signed this day January 26, 2016. Original Signed by Julie Grzyb _ S.Jay Zimmerman,P.G. Director,Division of Water Resources By Authority of the Environmental Management Commission Page 1 DocuSign Envelope ID:7327AB30-4FAB-4D2D-99C0-685FE978C6C2 Permit NC0024295 SUPPLEMENT TO PERMIT COVER SHEET All previous NPDES permits issued to this facility, whether for operation or discharge are hereby revoked. As of this permit issuance, any previously issued permit bearing this number is no longer effective. Therefore, the exclusive authority to operate and discharge from this facility arises under the permit conditions,requirements, terms, and provisions included herein. Transylvania Utilities, Inc. is hereby authorized to: 1. Continue to operate an existing 0.30 MGD wastewater treatment system with the following components: • Concrete influent flow splitter • Dual aeration basins with mechanical aerators • Dual rectangular clarifiers • Chlorine contact chamber • Flow meter • Liquid dechlorination system • Sludge digester with dewatering box This system discharges from Connestee Falls WWTP No.1 at 5999 Greenville Highway near Connestee Falls in Transylvania County. 2. After receiving an Authorization to Construct from the Division for expansion and submission of an approved engineer's certification for construction, construct and operate a 0.46 MGD wastewater treatment plant. 3. Discharge from said treatment works at the locations specified on the attached map into the French Broad River, a class B-Trout water in the French Broad River Basin. Page 2 DocuSign Envelope ID:7327AB30-4FAB-4D2D-99C0-685FE978C6C2 Permit NC0024295 PART I A. (1.)EFFLUENT LIMITS AND MONITORING REQUIREMENTS—Outfall 001 (0.3MGD) [15A NCAC 02B .0400 et seq., 02B .0500 et seq.] During the period beginning upon the effective date of this permit and lasting until expansion above 0.3 MGD or expiration, the permittee is authorized to discharge treated wastewater from outfall 001. Such discharges shall be limited and monitored) by the permittee as specified below: EFFLUENT CHARACTERISTICS EFFLUENT LIMITS MONITORING REQUIREMENTS Monthly Daily Measurement Sample Parameter-Parameter Code Average Maximum Frequency Sample Type Location Influent or Flow - 50050 0.30 MGD Continuous Recorder Effluent BOD5 (20 Deg. C) - C0310 30.0 mg/L 45.0 mg/L Weekly Composite Effluent Total Suspended Solids - C0530 30.0 mg/L 45.0 mg/L Weekly Composite Effluent Ammonia-Nitrogen (mg/L) - C0610 Twice /month Composite Effluent Fecal Coliform - (geometric mean)-31616 200/100 ml 400/100 ml Weekly Grab Effluent TotalResidual Chlorine 2 - 50060 28 µg/L Weekly Grab Effluent Temperature- (Deg. C) - 00010 Weekly Grab Effluent TotalPhosphorus- (mg/L) - C0665 Semi-annually Composite Effluent TotalNitrogen - (mg/L) - C0600 Semi-annually Composite Effluent pH -00400 >6.0 and<9.0 S.U. Weekly Grab Effluent Footnotes: 1. No later than 270 days from the effective date of this permit,begin submitting discharge monitoring reports electronically using NC DWR's eDMR application system. See Special Condition A.(3.). 2. The Division shall consider all effluent TRC values reported below 50 µg/1 to be in compliance with the permit. However,the Permittee shall continue to record and submit all values reported by a North Carolina certified laboratory(including field certified),even if these values fall below 50 µg/1. There shall be no discharge of floating solids or foam in other than trace amounts. Part I,Page 3 DocuSign Envelope ID:7327AB30-4FAB-4D2D-99C0-685FE978C6C2 Permit NC0024295 A. (2.)EFFLUENT LIMITS AND MONITORING REQUIREMENTS—Outfall 001 (0.46 MGD) [15A NCAC 02B .0400 et seq., 02B .0500 et seq.] Beginning upon expansion above 0.3 MGD and lasting until expiration, the permittee is authorized to discharge treated wastewater from outfall 001. Such discharges shall be limited and monitored1 by the permittee as specified below: EFFLUENT CHARACTERISTICS EFFLUENT LIMITS MONITORING REQUIREMENTS Monthly Daily Measurement Sample Parameter—Parameter Code Average Maximum Frequency Sample Type Location Influent or Flow - 50050 0.46 MGD Continuous Recorder Effluent BODs (20 Deg. C) - C0310 30.0 mg/L 45.0 mg/L Weekly Composite Effluent TotalSuspended Solids - C0530 30.0 mg/L 45.0 mg/L Weekly Composite Effluent Ammonia-Nitrogen (mg/L) - C0610 Twice /month Composite Effluent Fecal Coliform - (geometric mean)-31616 200/100 ml 400/100 ml Weekly Grab Effluent TotalResidual Chlorine 2 - 50060 28 µg/L Weekly Grab Effluent Temperature- (Deg. C) - 00010 Weekly Grab Effluent TotalPhosphorus- (mg/L) - C0665 Semi-annually Composite Effluent TotalNitrogen - (mg/L) - C0600 Semi-annually Composite Effluent pH -00400 >6.0 and<9.0 S.U. Weekly Grab Effluent Footnotes: 1. No later than 270 days from the effective date of this permit,begin submitting discharge monitoring reports electronically using NC DWR's eDMR application system. See Special Condition A.(3.). 2. Limit and monitor only if the facility adds chlorine or chlorine derivatives to water that is eventually discharged.The Division shall consider all effluent TRC values reported below 50 µg/1 to be in compliance with the permit. However,the Permittee shall continue to record and submit all values reported by a North Carolina certified laboratory(including field certified),even if these values fall below 50 µg/1. There shall be no discharge of floating solids or foam in other than trace amounts. Part I,Page 4 DocuSign Envelope ID:7327AB30-4FAB-4D2D-99C0-685FE978C6C2 Permit NC0024295 A (3)ELECTRONIC REPORTING OF DISCHARGE MONITORING REPORTS [G.S. 143-215.1(b)] Proposed federal regulations require electronic submittal of all discharge monitoring reports(DMRs)and specify that,if a state does not establish a system to receive such submittals,then permittees must submit DMRs electronically to the Environmental Protection Agency(EPA). The Division anticipates that these regulations will be adopted and is beginning implementation in late 2013. NOTE: This special condition supplements or supersedes the following sections within Part II of this permit (Standard Conditions for NPDESPermits): • Section B.(11.) Signatory Requirements • Section D.(2.) Reporting • Section D.(6.) Records Retention • Section E. (5.) Monitoring Reports 1. Reporting [Supersedes Section D.(2.)and Section E.(5.)(a)] Beginning no later than 270 days from the effective date of this permit,the permittee shall begin reporting discharge monitoring data electronically using the NC DWR's Electronic Discharge Monitoring Report (eDMR)internet application. Monitoring results obtained during the previous month(s)shall be summarized for each month and submitted electronically using eDMR The eDMR system allows permitted facilities to enter monitoring data and submit DMRs electronically using the internet. Until such time that the state's eDMR application is compliant with EPA's Cross-Media Electronic Reporting Regulation(CROMERR),permittees will be required to submit all discharge monitoring data to the state electronically using eDMR and will be required to complete the eDMR submission by printing,signing,and submitting one signed original and a copy of the computerprinted eDMR to the following address: NC DEQ/DWR/Information Processing Unit ATTENTION: Central Files/eDMR 1617 Mail Service Center Raleigh,North Carolina 27699-1617 If a permittee is unable to use the eDMR system due to a demonstrated hardship or due to the facility being physically located in an area where less than 10 percent of the households have broadband access,then a temporary waiver from the NPDES electronic reporting requirements may be granted and discharge monitoring data maybe submitted on paper DMR forms(MR 1, 1.1,2,3)or alternative forms approved by the Director. Duplicate signed copies shall be submitted to the mailing address above. Requests for temporary waivers from the NPDES electronic reporting requirements must be submitted in writing to the Division for written approval at least sixty(60)days prior to the date the facility would be required under this permit to begin using eDMR. Temporary waivers shall be valid for twelve(12)months and shall thereupon expire. At such time,DMRs shall be submitted electronically to the Division unless the permittee re-applies for and is granted a new temporary waiver by the Division. Information on eDMR and application for a temporary waiver from the NPDES electronic reporting requirements is found on the following web page: Part I,Page 5 DocuSign Envelope ID:7327AB30-4FAB-4D2D-99C0-685FE978C6C2 Permit NC0024295 http://portal.ncdenr.org/web/wq/admin/bog/ipu/edmr Regardless of the submission method,the first DMR is due on the last day of the month following the issuance of the permit or in the case of a new facility,on the last day of the month following the commencement of discharge. 2. Signatory Requirements [Supplements Section B.(11.)(b)and supersedes Section B.(11.)(d)1 All eDMRs submitted to the permit issuing authority shall be signed by a person described in Part II, Section B. (11.)(a)or by a duly authorized representative of that person as described in Part II,Section B. (11.)(b). A person,and not a position,must be delegated signatory authority for eDMR reporting purposes. For eDMR submissions,the person signing and submitting the DMR must obtain an eDMR user account and login credentials to access the eDMR system. For more information on North Carolina's eDMR system,registering for eDMR and obtaining an eDMR user account,please visit the following web page: http://portal.ncdenr.org/web/wq/admin/bog/ipu/edmr Certification. Any person submitting an electronic DMR using the state's eDMR system shall make the following certification[40 CFR 122.22]. NO OTHER STATEMENTS OF CERTIFICATION WILL BE ACCEPTED: "I certify, under penalty of law,that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted.Based on my inquiry of the person orpersons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best ofmy knowledge and belief true,accurate, and complete.I am aware that there are significant penalties for submitting false information, including the possibility offines and imprisonment for knowing violations." 3. Records Retention[Supplements Section D.(6.)] The permittee shall retain records of all Discharge Monitoring Reports,including eDMR submissions. These records or copies shall be maintained fora period of at least 3 years from the date of the report. This period may be extended by request of the Director at any time [40 CFR 122.41]. Part I,Page 6