Loading...
HomeMy WebLinkAboutNC0044423_202101VRR_20210414DMR REVIEW RECORD Winston-Salem Regional Office Facility Name: Appalachian State WTP Permit Number: NCO044423 Report Period: January 2021 Prior Assessments: 0 Enforcement Factor: 1.00 Waterbody Outfall # Outfall Description Waterbody Name Classification 001 Membrane/filter backwash to Norris Brch Norris Branch, including the raw water holding WS-II;Tr,HQW,CA reservoir below normal reservoir elevation Monthly Average Limit Violations Sample Location: Outfall 001 - Effluent Violation Unit of Limit Calculated % Over Date Parameter Frequency Measure Value Value Limit Action 1/31/2021 Copper, Total (as Cu) Monthly ug/I 4 65 1,525.0 Daily Limit Violations Sample Location: Outfall 001 - Effluent Violation Unit of Limit Calculated % Over Date Parameter Frequency Measure Value Value Limit Action 1/27/2021 Chlorine, Total Residual 2 X month ug/I 28 48 71.4 No Action, BPJ 1/13/2021 Copper, Total (as Cu) Monthly ug/I 5.20 65 1,150.0 Other Violations/Staff Remarks: Spoke with ORC to confirm Cu value of 65 ug/I, and it is correct. According to permit, limits on Cu began Jan. 1, 2021. Other stipulations in the permit required them to complete a (CAP) Corrective Action Plan within one year, submit a report outlining corrective actions taken to remedy matters summarized in CAP (at year 2, 3 & 4). They did complete CAP, however, did not report yearly (not that I found). Held meeting on 4/12/21 to discuss situation at facility and concluded with requiring facility to submit remedial strategy to DWR. (ie: moving discharge point, different filtration system). **CAP summary concerning Cu: "The ASU WTP is not a generator of copper and zinc and the WTP is not discharging metals from another source. The parameters are present in the source water withdrawn from the same water body they are being discharged back into." Possibly start with NOD, however due to high Cu reading, NOV?? Attached below are conversation notes- 4/6/2021 @ 9:45am Re: Copper = 65 ug/l on 1-2021 DMR (Cu limit: Monthly avg 4.0 ug/l ;Daily max 5.2 ug/1) •Value is confirmed, no typo/error in reporting. •Cu get `trapped' onto the membrane and during CIP backwash, the citric acid removes Cu from membranes and creates a `slug' going to wash basin. •Mr. Johnson stated high value is possible result of road salt over winter and CIP backwashes of plant. •Proposal has been made to increase frequency of backwashes, so Cu does not build up on the membranes. •Polymers and/or chemical treatments are avoided as not to complicate issues there. •Trying everything to come up with best route to keep this from occurring. •Stated another issue is ... discharge point (outfall) is 75-100 yards from plant intake. (Mr. Johnson's opinion is) - More Cu coming into plant than being discharge. Supervisor Remarks: Jenny — NOV Lon-NOV Completed by: Tricia Lowery Assistant Regional Supervisor Sign -off: Jenny Regional Supervisor Sign -off: LTS Date: 4/14/2021 Date: 4/19/2021 Date: 4/19/2021 Prior 12-Month Enforcement Histor Permit Number: NCO044423 Report Period: January 2021 Limit Violation Sample Location: Outfall 001 - Effluent Violation Report Violation Date Period Parameter Type NOD NOV CPA 1/29/2020 1-2020 Turbidity Daily Maximum NOV-2020-LV-0205 Exceeded 2/12/2020 2-2020 Turbidity Daily Maximum NOV-2020-LV-0294 Exceeded 2/26/2020 2-2020 Turbidity Daily Maximum NOV-2020-LV-0294 Exceeded 3/11/2020 3-2020 Turbidity Daily Maximum NOV-2020-LV-0411 Exceeded 3/25/2020 3-2020 Turbidity Daily Maximum NOV-2020-LV-0411 Exceeded 5/13/2020 5-2020 Turbidity Daily Maximum NOV-2020-LV-0568 Exceeded 5/27/2020 5-2020 Turbidity Daily Maximum NOV-2020-LV-0568 Exceeded 6/10/2020 6-2020 Turbidity Daily Maximum NOV-2020-LV-0712 Exceeded Other Violation Violation Report Violation Date Period Parameter Type NOD NOV CPA 1/9/2020 Violation detected NOD-2020-PC-0011 during inspection 1/9/2020 Violation detected NOD-2020-PC-0011 during inspection