HomeMy WebLinkAboutWQCS00230_Annual Report_20210422 Wastewater Treatment and Collection
Performance Annual Report
I. General Information
Facility/System Name: Pluris Webb Creek LLC. County: Onslow
Service Area Includes: Webb Creek& The Pines Subdivisions
Responsible Entity: Pluris Webb CreekLLC.
Contact Name/Phone #: Project Manager Randy Hoffer 910.327.2880
Applicable Permit(s): Permit Numbers NC006242/WQCS00230
Description of Collection System or Treatment Process:
NC006242 : Operation of a 0.350MGD MBR treatment facility consisting of 2 units.
: Operation and maintenance of approximately 19 miles of gravity sewer, 11 miles of
force main, 10 duplex stations amd 3 simplex stations with all associated piping, and valves
II. Performance
Overall Summary of System Performance for Calendar Year 2020:
The following lists any violations of permit conditions or environmental
regulations that may have occurred during the year. If a violation is listed,
a description of any known environmental impact including the corrective
measures taken is included.
Pluris Webb Creek LLC Annual Sewer Performance Report 2020 Page 1
January Violated daily and monthly max for enterococci - Process for new treatment facility
February Violated daily and monthly max for enterococci - Process for new treatment facility
March Violated daily and monthly max for enterococci -Process for new treatment facility
April Violated daily and monthly max for enterococci -Process for new treatment facility
May Violated daily and monthly max for enterococci - Process for new treatment facility
June Violated dailyand monthlymax for enterococci -Process for new treatment facility
July None
August Violated daily and monthly max for enterococci -Process for new treatment facility
September None
October None
November None
December None
III. Notification
Customers will be notified of the availability of this report with a message on
their bills and copies will be provided upon request.
IV. Certification
I hereby certify that the information contained in this report is accurate and
complete to the best of m knowledge.
7‘",=7
January 7,2021
'gna a of Re si Person Date
Randy Hoffer Regional Manager
Printed Name Title
Iri P u s Webb Creek LLC Annual Sewer Performance Report 2020 Page 2
SERVICE AREAS 2020
(Note: If more columns are needed for additional subdivisions or service areas,attach supplementary sheets)
Name of subdivision or service area: Pluris Webb Creek
Water: DEHNR System Identification No.: N/A
Sewer: NPDES or Discharge Permit No.: NC0089877
County (or Counties). Onslow
Type of Service (Check one or more):
Water Service
Sewer Service X
Fire Protection Service
(Check only when billed separately from water service)
Number of wells in service:
Total pumping capacity of pumps in service (gpm)
Total storage tank capacity (gallons)
Source of water supply (Check one or more):
Pumped from wells
Purchased from others
Other
Not applicable X
Type of water treatment (Check one or more):
Chlorination
Iron Treatment
Other
Not applicable X
Are hydrants and elevated tanks available for fire protection?
Yes, Fire Protection availability
No hire Protection availability
Is service metered: (Check one or more):
Yes, Meters
No Meters
Source of sewage treatment (Check one or more):
Treat own sewage X
Other
Not applicable
Number of customers at the end of report year:
Water Service N/A
Sewer Service 1,339
Number of customers that can be served by mains already
installed (include present customers,vacant lots,etc.):
Water Service N/A
Sewer Service 1,500 0.350MGD
Number of availability customers at end of report years
(Only applicable for companies charging availability rates separate
from water service) :
Water Service N/A
Sewer Service N/A
. _ .
. .
SEWER EQUIPMENT 2020 _ ..-i.-. . ,-.. :r.. .-- :H:ii
-SUBDIVISION OR SERVICE AREA: Pluris Webb Creek
''''''' .'''''''' .'•••'•::: .••:-•'•:• :.: ••'•••••'•'•••1•1•1•1:PUMP1NG EQUIPMENT.H.H.H.H:H. iinT :::.:ni.i.1..:.::.:.:::::..1: ::::::::::::H::::::::.:.:.:.:.:.:.:.:.:
::.:. - .. ......... - .::..:.::•:•:. ., .. ..
LOCATION DESCRIPTION PUMP CAPACITY
•
(Lot Number, etc.) (Pumping Stations, et iga In ••
•
• 10 Pump Stations ..
...
::::::::TREAT.MENTEQULP.NINTaiiHi: E::...:..::.:. :::::::=: ii :H:i:i::H:H:::::: :::::::i:
LOCATION DESCRIPTION TREATMENT CAPACITY
...
•
•• (Lot Number, etc.) igallons/day) ...
••
Webb Creek NC SBR Out date June 25 2020 0.300MGD
Direct Discharge
...
ADVANCED BIOLOGICAL
•
• MEMBRANE REACTOR 0.350MGD .
•..•
.STARTED JUNE 15 2020 ..
••
. . •:-.... ... . . .. .. . .... .
. ...
... FORCE MAINS.•::?:::: :.:::::.:.:,1,1,:,,,,, ::::::::::•.:: r.:.. .. . GRAVITY MAINS1.:::
......... ... . ... .
Diameter of Force Mains Length of Force Mains(L.F.) . • Diameter of Gravity Mains Length of Gravity Mains(L.F.)
2" 1,200 :6"
•: .3..
:8" 100,320 ...
4" 1,425 '10"
i 5" 2,350 12"
..: 8" 26400 .15" "••
••
: 10" . . ••
••
:.: 12" : . .•
•
.............:::::2 ..S.::::j:•: .. SERVICE C.ONN:ECTIONS.........::::::::H.H.i.H H H ..... .. . .....:::::::;.:..,.....:............
" TOTAL NUMBER TAPS SIZE OF SERVICE TAPS Lt_
NUMBER OF TAPS IN SERVICE
: INSTALLED ,
1,500 1,339 4" Gravity 2" Forcemain ...
OTHER SEWER PROPERTY: 2 -F150 Trucks 1 Portable Bypass Pumps
INFORMATION RELATIVE TO CONTRIBUTIONS IN AID OF CONSTRUCTION (CIAC)
Water Sewer Combined
1. Nontaxable CIAC collected during this 12-mo. Report Period
2. Taxable CIAC collected during this 12-mo. Report Period
3. Tax collected on taxable CIAC during this 12-mo. Report Period
4. Cumulative nontaxable CIAC collected
5. Cumulative taxable CIAC collected
CERTIFICATION:
I hereby certify that the information contained in this annual report is true to the best of my knowled d belief:
c--
1/7/2021
Date
J re