HomeMy WebLinkAboutWQCS00230_Annual Report_20210422 Wastewater Treatment and Collection Performance Annual Report I. General Information Facility/System Name: Pluris Webb Creek LLC. County: Onslow Service Area Includes: Webb Creek& The Pines Subdivisions Responsible Entity: Pluris Webb CreekLLC. Contact Name/Phone #: Project Manager Randy Hoffer 910.327.2880 Applicable Permit(s): Permit Numbers NC006242/WQCS00230 Description of Collection System or Treatment Process: NC006242 : Operation of a 0.350MGD MBR treatment facility consisting of 2 units. : Operation and maintenance of approximately 19 miles of gravity sewer, 11 miles of force main, 10 duplex stations amd 3 simplex stations with all associated piping, and valves II. Performance Overall Summary of System Performance for Calendar Year 2020: The following lists any violations of permit conditions or environmental regulations that may have occurred during the year. If a violation is listed, a description of any known environmental impact including the corrective measures taken is included. Pluris Webb Creek LLC Annual Sewer Performance Report 2020 Page 1 January Violated daily and monthly max for enterococci - Process for new treatment facility February Violated daily and monthly max for enterococci - Process for new treatment facility March Violated daily and monthly max for enterococci -Process for new treatment facility April Violated daily and monthly max for enterococci -Process for new treatment facility May Violated daily and monthly max for enterococci - Process for new treatment facility June Violated dailyand monthlymax for enterococci -Process for new treatment facility July None August Violated daily and monthly max for enterococci -Process for new treatment facility September None October None November None December None III. Notification Customers will be notified of the availability of this report with a message on their bills and copies will be provided upon request. IV. Certification I hereby certify that the information contained in this report is accurate and complete to the best of m knowledge. 7‘",=7 January 7,2021 'gna a of Re si Person Date Randy Hoffer Regional Manager Printed Name Title Iri P u s Webb Creek LLC Annual Sewer Performance Report 2020 Page 2 SERVICE AREAS 2020 (Note: If more columns are needed for additional subdivisions or service areas,attach supplementary sheets) Name of subdivision or service area: Pluris Webb Creek Water: DEHNR System Identification No.: N/A Sewer: NPDES or Discharge Permit No.: NC0089877 County (or Counties). Onslow Type of Service (Check one or more): Water Service Sewer Service X Fire Protection Service (Check only when billed separately from water service) Number of wells in service: Total pumping capacity of pumps in service (gpm) Total storage tank capacity (gallons) Source of water supply (Check one or more): Pumped from wells Purchased from others Other Not applicable X Type of water treatment (Check one or more): Chlorination Iron Treatment Other Not applicable X Are hydrants and elevated tanks available for fire protection? Yes, Fire Protection availability No hire Protection availability Is service metered: (Check one or more): Yes, Meters No Meters Source of sewage treatment (Check one or more): Treat own sewage X Other Not applicable Number of customers at the end of report year: Water Service N/A Sewer Service 1,339 Number of customers that can be served by mains already installed (include present customers,vacant lots,etc.): Water Service N/A Sewer Service 1,500 0.350MGD Number of availability customers at end of report years (Only applicable for companies charging availability rates separate from water service) : Water Service N/A Sewer Service N/A . _ . . . SEWER EQUIPMENT 2020 _ ..-i.-. . ,-.. :r.. .-- :H:ii -SUBDIVISION OR SERVICE AREA: Pluris Webb Creek ''''''' .'''''''' .'•••'•::: .••:-•'•:• :.: ••'•••••'•'•••1•1•1•1:PUMP1NG EQUIPMENT.H.H.H.H:H. iinT :::.:ni.i.1..:.::.:.:::::..1: ::::::::::::H::::::::.:.:.:.:.:.:.:.:.: ::.:. - .. ......... - .::..:.::•:•:. ., .. .. LOCATION DESCRIPTION PUMP CAPACITY • (Lot Number, etc.) (Pumping Stations, et iga In •• • • 10 Pump Stations .. ... ::::::::TREAT.MENTEQULP.NINTaiiHi: E::...:..::.:. :::::::=: ii :H:i:i::H:H:::::: :::::::i: LOCATION DESCRIPTION TREATMENT CAPACITY ... • •• (Lot Number, etc.) igallons/day) ... •• Webb Creek NC SBR Out date June 25 2020 0.300MGD Direct Discharge ... ADVANCED BIOLOGICAL • • MEMBRANE REACTOR 0.350MGD . •..• .STARTED JUNE 15 2020 .. •• . . •:-.... ... . . .. .. . .... . . ... ... FORCE MAINS.•::?:::: :.:::::.:.:,1,1,:,,,,, ::::::::::•.:: r.:.. .. . GRAVITY MAINS1.::: ......... ... . ... . Diameter of Force Mains Length of Force Mains(L.F.) . • Diameter of Gravity Mains Length of Gravity Mains(L.F.) 2" 1,200 :6" •: .3.. :8" 100,320 ... 4" 1,425 '10" i 5" 2,350 12" ..: 8" 26400 .15" "•• •• : 10" . . •• •• :.: 12" : . .• • .............:::::2 ..S.::::j:•: .. SERVICE C.ONN:ECTIONS.........::::::::H.H.i.H H H ..... .. . .....:::::::;.:..,.....:............ " TOTAL NUMBER TAPS SIZE OF SERVICE TAPS Lt_ NUMBER OF TAPS IN SERVICE : INSTALLED , 1,500 1,339 4" Gravity 2" Forcemain ... OTHER SEWER PROPERTY: 2 -F150 Trucks 1 Portable Bypass Pumps INFORMATION RELATIVE TO CONTRIBUTIONS IN AID OF CONSTRUCTION (CIAC) Water Sewer Combined 1. Nontaxable CIAC collected during this 12-mo. Report Period 2. Taxable CIAC collected during this 12-mo. Report Period 3. Tax collected on taxable CIAC during this 12-mo. Report Period 4. Cumulative nontaxable CIAC collected 5. Cumulative taxable CIAC collected CERTIFICATION: I hereby certify that the information contained in this annual report is true to the best of my knowled d belief: c-- 1/7/2021 Date J re