HomeMy WebLinkAboutNCG030255_2021 DMR_20210416NCDEQ Division of Energy, Mineral and Land Resources
Stormwater Discharge Monitoring Report (DMR) Form for NCG030000
Metal Fabrication
Click here for instructions
Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within
30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office.
Certificate of Coverage No. NCG03 0255
Person Collecting Samples: Curtis Daniels
Facility Name: J.C. Steele and Sons
Laboratory Name: Statesville Analytical
Facility County:lredell
Laboratory Cert. No.: 440
Discharge during this period:❑✓ Yes ❑ No (if no, skip to signature and date)
Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? ❑ Yes 0 No
If so, which Tier (I, II, or III)?
A copy of this DMR has been uploaded electronically via https://edocs.deg.nc.gov/Forms/SW-DMR ❑ Yes Q No
Date Uploaded: 4/16/2021
Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red)
Parameter
Code
Parameter
outfall1
Outfall 3
outfall
Outfall
outfall
N/A
Receiving Stream Class
C
C
N/A
Date Sample Collected MM/DD/YYYY
03/31/2021
03/31/2021
46529
24-Hour Rainfall in inches
.60"
.60"
C0530
TSS in mg/L (100 or 50*)
6.588
5.806
00400
pH in standard units (6.0-9.0)
6.8
6.8
01119
Copper, total recoverable in mg/L
0.006
0.0085
(0.010)
01051
Lead, total recoverable in mg/ L
<0.002
c0.002
(0.075)
01094
Zinc, total recoverable in mg/ L
0.078
0.2
(0.126)
Total Toxic Organics (TTO) in mg/L(1)
78141
(if required)
00552
1 Non -Polar Oil & Grease in mg/L (15)
<5.15
<5.08
Additional parameters for outfalls in drainage areas that use >55 gallons per month of new hydraulic oil on average
Estimated New Motor/Hydraulic Oil
NCOIL
Usage in gal/month
5
5
* Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA)
have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L
Notes (optional): Zinc levels above benchmark at OF3, recieved letter of relief in 2015 from Zahid S,Khan
"I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in
accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my
inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information
submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting
false inforypation, jncluding�_ possibilitylof fines and imprisonment for knowing violations."
Signature of Permittee or Delegated Authorized Individual
4/16/2021
Date
Email Address cld@jcsteele.com 704-768-3230
Phone Number