Loading...
HomeMy WebLinkAboutNC0078955_Inspection_20040604Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality June 4, 2004 Joseph Campbell City of Dunn PO Box 1065 Dunn NC 28335 SUBJECT: June 2, 2004 Compliance Evaluation Inspection City of Dunn Dunn WTP Permit No: NC0078955 Harnett County Dear Mr. Campbell: Enclosed please find a copy of the Compliance Evaluation Inspection form from the inspection conducted on June 2, 2004. The Compliance Evaluation Inspection was conducted by Michael Lawyer of the Fayetteville Regional Office. The facility was found to be in Compliance with permit NC0078955. Please refer to the enclosed inspection report for additional observations and comments. If you, or your staff, have any questions, please call me at (910) 486-1541, ext. 724. Sincerely, Michael Lawyer Environmental Technician cc: Darryl T Glover, ORC Central Files Fayetteville Files i <+=LIEN NCDENR Division of Water Quality 225 Green Street -Suite 714 Fayetteville, NC 28301-50431 (910)486-1541 Telephone (910)486-0707 Fax Customer Service 1 877 623-7748 United States Environmental Protection Agency EPA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No, 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection 1 U 2 U 3 I NC0078955 1 11 121 04/06/02 117 Type Inspector Fac Type 18 U 19 U 2011 Remarks 21111111111111 111111111111 1111111111111111111111166 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA --------- ----- --------Reserved---------- --- ---- 67 I 3.0 169 70 Li 71 U 72 UT 731 I 174 MI 1 1 I 1 1180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Dunn WTP E Street ,- Dunn NC 28334 Entry Time/Date 09:30 AM 04/06/02 Permit Effective Date 01/11/01 Exit Time/Date 10:40 AM 04/06/02 Permit Expiration Date 06/09/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Darryl T Glover/ORC/910-897-5129/ /// Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Joseph Campbell,PO Box 1065 Dunn NC 28335//910-897-5129/ No Section C:. Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement 1 Operations & Maintenance • Records/Reports Self -Monitoring Program Sludge Handling Disposal 1 Facility Site Review 1 Effluent/Receiving Waters Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Mike Lawyer ( FRO WQ//91048615411726/910-486-0707 60f4 Y igna a of anage ent Q A Reviewer Agency/Office/Phone and Fax Numbers Date 7S7 EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. NPDES yr/mo/day Inspection Type 31 NC0078955 111 12 04/06/02 117 18 (cont.) 1 Section D: Summaryof Finding/Comments (Attach additional sheets of narrative and checklists as necessary) A review of the Discharge Monitoring Reports and lab reports from January 2004 through April 2004 revealed no NPDES permit violations. Residual chlorine, settleable solids and pH are analyzed on -site while suspended residue is analyzed at the City of Dunn WWTP Laboratory. Chemical and Environmental Technologies, Inc. is utilized for analyzing aluminum and iron. The wastewater for this facility is comprised of alum sludge and filter backwash which'is pumped into a lined settling basin. When the basin reaches capacity for sludge it is pumped out and land applied. At the time of inspection, the settling basin appeared to be in compliance. The outfall was easily accesible and the effluent clear. Permit: NC0078955 Owner - Facility: City of Dunn - Dunn WTP Inspection Date: 06/02/04 Inspection Type: Compliance Evaluation permit (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: $ )nerations & Maintenance Does the plant have general safety structures in place such as rails around or covers over tanks, pits, or wells? Is the plant generally clean with acceptable housekeeping? Comment: J ahnratnry Are field parameters performed by certified personnel or laboratory? Are all other parameters(excluding field parameters) performed by a certified lab? Is the facility using a contract lab? Are analytical results consistent with data reported on DMRs? Is proper temperature set for sample storage (kept at 1.0 to 4.4 degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? Incubator (SOD) set to 20.0 degrees Celsius +/- 1.0 degrees? Comment: pecord Keening Are records kept and maintained as required by the permit? Is all required information readily available, complete and current? Are all records maintained for 3 years (lab. reg. required 5 years)? Are analytical results consistent with data reported on DMRs? Are•sampling and analysis data adequate and include: Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of personperforming analyses Transported COCs Plant records are adequate, available and include O&M Manual As built Engineering drawings Schedules and dates of equipment maintenance and repairs Are DMRs complete: do they include all permit parameters? Has the facility submitted its annual compliance report to users? (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified,at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Is the facility description Verified as contained in the NPDES permit? Yes No NA NF ❑ ❑ • ❑ ■ ❑ ❑ ❑ O 1100 • 000 ▪ ❑ ❑ ❑ Yes No NA NF • 000 • 000 Yes Nn NA NF • 000 • 000 • 000 • 000 O 0011 O 0110 ❑ ❑ ■ O Yes No NA NF • 000 • 000 1.000 • 000 • 000 • • • • • • O O ❑ ■ 0 0 11000 ❑ ❑ • ❑ • 000 O 0011 • 000 • 000 ■ ❑ O O • 000 Permit: NC0078955 Owner - Facility: City of Dunn - Dunn WTP Inspection Date: 06/02/04 Inspection Type: Compliance Evaluation Record Keening Does the facility analyze process control parameters, for example: MLSS, MCRT, Settleable Solids, DO, Sludge Judge, pH, and others that are applicable? Facility has copy of previous years Annual Report on file for review? Comment: FffluPnt Pine Yes No NA NF Is right of way to the outfall properly maintained? •❑ ❑ ❑ Are receiving water free of solids and floatable wastewater materials? •❑ ❑ ❑ Are the receiving waters free of solids / debris? ❑ ❑ ❑ Are the receiving waters free of foam other than a trace? •❑ ❑ ❑ Are the receiving waters free of sludge worms? •❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? 0 ❑ •❑ Comment: YQs No NA NF O DOM O 0,0