Loading...
HomeMy WebLinkAboutNC0078955_Inspection_20050322Michael F. Easley, Govemor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E., Director Division of Water Quality March 22, 2005 Michael Uskiewicz City of Dunn PO Box 1065 Dunn, NC 28335 SUBJECT: March 18, 2005 Compliance Evaluation Inspection City of Dunn Dunn WTP Permit No: NC0078955 Harnett County Dear Mr. Uskiewicz: Enclosed please find a copy of the Compliance Evaluation Inspection Report from the inspection conducted on March 18, 2005 by Mike Lawyer of the Fayetteville Regional Office. The inspection revealed the following items, which must be addressed. The chlorine meter being used for the weekly chlorine monitoring must be calibrated either annually with a five -point curve or before each use with a three-point curve. Documentation of this calibration must be kept in a manner in which it can be presented upon request by an inspector. There was no ORC visitation log. It was suggested during the inspection that Mr. Glover initial the daily operations and maintenance book on those days that he is present at the plant. Also, the Dunn WTP is required to either attain a certification to perform the upstream and downstream monitoring of turbidity or have another facility that is currently certified to perform the tests. Information on attaining certification for specific parameters can be found under the Laboratory Section of our website, located at the bottom of this page. Please respond to this office in writing as to your plans to address the aforementioned items by April 30, 2005. Please refer to the enclosed inspection report for additional observations and comments. If you or your staff has any questions, please call me at 910-486-1541, ext. 729. Sincerely, Mike Lawyer Environmental Technician cc: Darryl T Glover, ORC Central Files Fayetteville Files j 1/6;ve,-; Ozc, Jf_ ,tom- fteeked re7aoY' oallNty North Carolina Division of Water Quality 225 Green Street — Suite 714 Fayettevuio, _1' 486-1541 Customer Service Internet: h2o.enr.state.nc.us FAX (91u) 486-0707 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer-50% Recycled/10% Post Consumer Paper United States Environmental Protection Agency EPA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection 1 LI 2 L5 I 3 I N00078955 111 121 05/03/18 117 Type Inspector Fac Type 18 U 19I S I 2011 Remarks 211111111111111111111111111111111111111111111111166 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ------------Reserved- 67 L 3.0 169 70 111 71 I J 72 LI 73 I I 174 75I I I I I I I 180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Dunn WTP E St Dunn NC 28334 Entry Time/Date 09:30 AM 05/03/18 Permit Effective Date 01/11/01 Exit Time/Date 11:30 AM 05/03/18 Permit Expiration Date 06/09/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Darryl T Glover/ORC/910-897-5129/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Michael Uskiewicz,PO Box 1065 Dunn NC 28335/City Contacted Manager/910-892-2633/9108922073 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance Records/Reports Self -Monitoring Program Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Mike Lawyer FRO WQ/// Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. NPDES 31 NC0078955 111 12I yr/mo/day 05/03/18 I17 Inspection Type 18 (cont.) 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) A review of the DMR's from July 2004 through January 2005 revealed no permit violations with regards to effluent monitoring. During the inspection it was noted that the chlorine meter is not being calibrated and that there was no ORC visitation log. The chlorine meter must be calibrated either annually with a five point curve or before each test with a three point curve. Personnel at the Dunn WWTP can assist in this calibration. It is suggested that the ORC initial the daily maintenance book with which the Back-up ORC's have been signing on the days he is present at the plant. At the time of inspection, the grounds of the plant appeared to be well -maintained and the discharge coming over the weir at the return pump basin was clear. Permit Yes No NA NF (If the present permit expires in 6 months or less). Has the permittee submitted a new application? 0 0 • 0 Is the facility as described in the permit? • ❑ ❑ ❑ Are there any special conditions for the permit? ❑ 1 ❑ ❑ Is access to the plant site restricted to the general public? •❑ ❑ ❑ Is the inspector granted access to all areas for inspection? M ❑ ❑ ❑ Comment Operations & Maintenance Yes No NA NF Does the plant have general safety structures in place such as rails around or covers over tanks, pits, or wells? •❑ ❑ ❑ Is the plant generally clean with acceptable housekeeping? •❑ ❑ ❑ Comment: Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? •❑ ❑ ❑ Are all other parameters(excluding field parameters) performed by a certified lab? •❑ ❑ ❑ Is the facility using a contract lab? 1 ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? ■ ❑ ❑ ❑ Is proper temperature set for sample storage (kept at 1.0 to 4.4 degrees Celsius)? 111000 Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? 0 0 • 0 Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? ❑ ❑ M ❑ Comment: Record Keeping Yes No NA NF Are records kept and maintained as required by the permit? 111000 Is all required information readily available, complete and current? 1 ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? M000 Are analytical results consistent with data reported on DMRs? 1.000 Are sampling and analysis data adequate and include: 1 ❑ ❑ ❑ Dates, times and location of sampling 1 Name of individual performing the sampling � Results of analysis and calibration 0 Dates of analysis 1 Name of person performing analyses • Transported COCs � Plant records are adequate, available and include M ❑ ❑ ❑ O&M Manual As built Engineering drawings 1 Schedules and dates of equipment maintenance and repairs Are DMRs complete: do they include all permit parameters? •❑ ❑ ❑ Has the facility submitted its annual compliance report to users? 00.0 (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? 00.0 Is the ORC visitation log available and current? 0.00 Is the ORC certified at grade equal to or higher than the facility classification? •❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility classification? • ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? • ❑ ❑ ❑ Is the facility description verified as contained in the NPDES permit? M ❑ ❑ ❑ Does the facility analyze process control parameters, for example: MLSS, MCRT, Settleable Solids, DO, Sludge ❑ ❑ • ❑ Judge, pH, and others that are applicable? Record Keening_ Facility has copy of previous year's Annual Report on file for review? Comment: The chlorine meter is not being calibrated. There is no ORC visitation log. Upstream / Downstream Sampling Is the facility sampling performed as required by the permit (frequency, sampling type, and sampling location)? Comment: Effluent Pipe Is right of way to the outfall properly maintained? Are receiving water free of solids and floatable wastewater materials? Are the receiving waters free of solids / debris? Are the receiving waters free of foam other than a trace? Are the receiving waters free of sludge worms? If effluent (diffuser pipes are required) are they operating properly? Comment Yes No NA NF ❑ ❑ ■ ❑ Yes No NA NF ■ ❑ ❑ ❑ Yes No NA NF • ❑ ❑ ❑ 110013 • � ❑ ❑ ❑ ❑ ❑ ❑ ▪ ❑ ❑ ❑ ❑ ❑ • ❑ CITY OF DUNN POST OFFICE BOX 1065 • DUNN • NORTH CAROLINA 28335 PUBLIC WORKS DEPARTMENT • (910) 892-2948 • FAX (910) 892-8871 May 16, 2005 NC Division of Water Quality Water Quality Environmental Technician Mr. Mike Lawyer 225 Green Street, Suite 714 Fayettville, North Carolina 28301 — 5043 Reference: Reply to the Compliance Evaluation Report. Dear Mr. Lawyer: DENR -- Fr Yr i I EV;LLE REGIONAL OFFICE I am responding, to the corrections we need to make for our NPDES permit. have reviewed all the recommended changes in your Evaluation Report. 1. The Chlorine Meter at the WTP is going to be Calibrated Annually with a 5 Point Calibration Curve. We will keep this record on file for review. The WWTP is currently performing this test for us in the 15 minute hold time allowed for Total Chlorine Residuals. 2. The ORC Visitation Log issue will be handled by my signing the Operators Daily Logbook each day. I am typically on the job 5 days a week. I will have the Backup ORC sign in on the days I am not at the Plant for vacation or sickness related absences. 3. The Upstream and Downstream Monitoring, for Turbidity is currently being performed by Chemical and Environmental Tech. A Certified Lab in Cary, NC. The City of Dunn is currently a member of the Middle Cape Fear River Basin Association. I am hoping this contract removes us from the requirement of having to sample for up and downstream monitoring. Attached is a copy of our contract with the MCRBA. Also attached is a copy of the Operators Daily Log Sheet with my signature as the ORC signed in. bald A4Amarica City 1 Home ofMaj. Gen. William C. Lee I I I "Father of the Airborne" am sorry for not getting this reply back to your office in a speedy reply. I did not receive any information due to the letter you wrote being lost or misplaced in transit. If I can be of any further help in this matter let me know. Sincerely, bia'A)6)) Darryl Glover Dunn WTP PC1 ORC NPDES Permit # NC0078955 DATE J - O S OPERATOR IN: Wes OPERATOR OUT: ( $/' . f PLANT OPERATIONS / PROBLEMS �.G, , ,✓ ?JES C57oo .Ran 7 s�- ("I I P S -I-r C a +r S-J'r C a E ts4 O O S G rA 0( I k �i-a L ()a (-IS OPERATOR IN: OPERATOR OUT: PLANT OPERATIONS / PROBLEMS CHEMICALS LOW : REAGENTS LOW : 4,4FAA. NCDENR Memorandum of Agreement Between The State of North Carolina's Division of Water Quality And The Middle Cape Fear River Basin Association Permittees Effective: July 1, 2003 through June 30, 2008 -- Revision 1.0 Table 1. MCFRBA PERMITTEES IN SUB BASIN ORDER (Section D Contains the Signature Sheets) NPDES Middle Cape Fear Basin Association Permit Permittees, Number Ownership and Facility NC0003433 NC0039586 NC0030091 NC0021636 NC0007684 NC0059242 NC0028118 NC0048101 NC0063096 NC0038831 CP&L - A Progress Energy Company - Cape Fear Steam Electric Power Plant CP&L - A Progress Energy Company - Shearon Harris Nuclear Power Plant Harnett County Public Utilities - Buies Creek WWTP Harnett County Public Utilities - North Harnett Regional WWTP Harnett County Public Utilities - Harnett County Regional WTP Town of Broadway - Broadway WWTP Town of Fuquay-Varina - Kenneth Creek WWTP Harnett County Public Utilities — Senter's Rest Home Town of Holly Springs - Town of Holly Springs WWTP Carolina Trace Utilities Inc. - Carolina Trace Utilities Inc Authorized Representative and Title Mr. Robert E. Beasley, Plant Manager Mr. B.C. Waldrop, Plant General Manager Mr. Rodney Tart, Director of Public Utilities Mr. Rodney Tart, Director of Public Utilities Mr. Rodney Tart, Director of Public Utilities Mr. Robert W. Stevens, Town Manager Mr. John Ellis, Town Manager Mr. Gary Averitte ORC Mr. Thomas Tillage, Director of Water Quality Mr. Carl Daniel, VP and Regional Director Mr. Michael Uskiewicz, County Chatham Wake Harnett Harnett Harnett Lee Wake Harnett Wake Lee Harnett Sub Basin 30607 30607 30607 30607 30607 30607 30607 30607 30607 30613 30613 City of Dunn — Dunn W W t t' v.iLy iviuuasa.' NC0043176 Town of Erwin — Erwin WWTP Mr. Patrick Childs, er Town Manager Harnett 30613 NC0064521 ` Town of Erwin — Erwin WTP .Mr. Patrick Childs, er Town Manager Harnett 30613 NC0080560 Harnett County Public Utilities - South Central Water & Sewer District WWTP Mr. Rodney Tart, Director of Public Utilities Harnett 30614 NC0031470 NC0030970 Town of Spring Lake - Spring Lake WWTP Mr. Joel A. Davis, Town Manager Cumberland 30614 US Army - Fort Bragg WWTP & WTP Colonel Gregory G. Bean, Director PWBC Cumberland 30614 NC0003964 NC0026514 City of Raeford - Raeford WWTP Mr. Mike McNeill, City Manager Hoke 30615 NC0003719 Monsanto Company Mr. Manhar Patel, Business Unit Manager Cumberland 30615 NC0023957 PWC/Fayetteville - Cross Creek WWTP Mr. Mick Noland, COO Water Resources Cumberland 30615 NC0050105 PWC/Fayetteville - Rockfish Creek WWTP Mr. Mick Noland, COO Water Resources Cumberland 30615 NC0076783 PWC/Fayetteville - Hoffer WTP Mr. Mick Noland, COO Water Resources Cumberland 30615 NC0003573 Dupont Corporation - E.I. DuPont Fayetteville works Mr. Barry L. Hudson, Plant Manager Bladen 30616 NC0078344 Smithfield Packing Company Inc. — Tarheel Plant Mr. Larry Johnson, VP and General Manager Bladen 30616 NC0026671 Town of Elizabethtown - Elizabethtown WWTP Mr. Stephen C. Williams, Director of Public Services Bladen 30616 Veeder Root Company Mr. Wes Hackney, Quality/Environmental Manager Bladen 30616 NC0001121 MCFRBA_MOA_Rev 01.0 6/21/04646/0461-1-5/04 Page 6 of 262f22 SECTION D — Continued. MCFRBA COALITION MEMBER SIGNATURES Permittee Town of Broadway Broadway WWTP Permittee Town of Fuquay-Varina Kenneth Creek WWTP Permittee Town of Holly Springs Town of Holly Springs WWTP Permittee Carolina Trace Utilities Inc. Carolina Trace Utilities Permittee City of Dunn Dunn WWTP Permittee Town of Erwin Erwin WWTP Permittee Town of Erwin Erwin WTP NPDES Number NC0059242 NPDES Number NC0028118 NPDES Number NC0063096 NPDES Number NC0038831 NPDES Number NC0043176 NPDES Number NC0064521 NPDES Number NC0080560 Signature Signature Received 6/17/2003 Mr. Robert W. Stevens Town Manager Signature Signature Received 6/25/2003 Mr. John Ellis Town Manager Signature Signature Received 6/17/2003 Mr. Thomas Tillage Director of Water Quality Signature Signature Received 6/17/2003 Mr. Carl Daniel VP and Regional Director Signature Signature Received 6/06/2003 Mr. Michael Uskiewicz City Manager Signature Signature Received 6/17/2003 Mr. Patrick Childs Town Manager Signature Signature Received 6/17/2003 Mr. Patrick Childs Town Manager MCFRBA MOA Rev 01.0 6/21/046/16/016/15/01 Page 18 of 262626 9108928871 • Public Works 01:58:11 p.m. 2005-05-13 1 /6 May 5, 2004 In reply to: Quote Request Mr. Charles W. Ham Jr. Chairman, Middle Cape Fear River Basin Association Dear Mr. Ham, Thank you, for considering Meritech, Inc. for your testing needs. The following is an outline of the parameters that you have requested along with the associated costs. Our standard turn around time for the analyses is ten (10) working days. The complete spreadsheet based report will be complete within thirty days (30) of the month the samples are taken Meritech, Inc. will use the current MOA as guidance to sampling and analysis, some of the parameters have detection levels lower than our current levels, and I have included our reporting limits for reference. Test Method Reporting Limit (mg/1) Quantity Per Year Cost Per Test Total Cost Fecal Coliform SM 9222D (MF) 1 coll100m1 360 $17.00 $6,120.00 Ammonia Nitrogen EPA 350.1 0.1 360 $10.00 $3,600.00 Total Kjeldahl Nitrogen (TKN) EPA 351.1 0.5 360 $15.00 $5,400.00 Nitrate/Nitrite Nitrogen EPA 353.2 0.1 360 $10.00 $3,600.00 Phosphorous, total EPA 365.2 0.05 360 $12.00 $4,320.00 I 91089288719 ' Public Works 01:58:47 p.m. 2005-05-13 216 Total Suspended Solids EPA 160.2 1 360 $8.00 $2,880.00 Turbidity EPA 180.1 1.0 NTU 360 $10.00 $3,600.00 Aluminum, total EPA 200.7 0.050 30 $11.00 $330.00 Arsenic, total EPA 200.7 0.010 30 $11.00 $330.00 Cadmium, total EPA 200.8 0.0005 30 $18.00 $540.00 Chromium, total EPA 200.7 0.005 30 $11.00 $330.00 Copper, total EPA 200.7 0.002 30 $11.00 $330.00 Iron, total EPA 200.7 0.025 30 $11.00 $330.00 Lead, total EPA 200.8 0.0005 30 $18.0D $540.00 Manganese, total EPA 200.7 0.005 30 $11.00 $330.00 Mercury, total (Low Level) Sample +Field Blank EPA 1631 1.0 ng/1 30 $130.00 $3,900.00 Nickel, total EPA 200.8 0.0005 30 $18.00 $540.00 Zinc, total EPA 200.7 0.010 30 $11.00 $330.00 Chlorophyll a SM 10200H 1 ug/1 20 $70.00 $1,400.00 Field Sampling -1 - - 6 months $2,520.00/mo $15,120.00 Field Sampling - 2 - - 6 months $3,960.00/mo $23,760.00 Yearly Total - - - - $77,630.00 • Field Sampling 1- November, December, January, February, March, and April. • Field Sampling 2 - May, June, July, August, September, and October. • Field sampling events will include pH, Temperature, DO and Conductivity at the surface of sampling site, as well as, middle and bottom as defined in the MOA. 2 9108928871 Public Works 01:59:25 p.m. 2005-05-13 3 /6 The pricing reflects costs incurred the first year of sampling and analysis. Each subsequent year would be subject to an increase of three percent (3%) per year, plus inflation, to the total investment. The above terms would be valid for three years from the date of acceptance. Meritech, Inc. would require sixty days (60) to implement the sampling plan from the date the contract is awarded. Should you have any question or require further information please feel free to contact me at your convenience. Regards, Frank A. Pasztor Laboratory Manager Meritech, Inc. 3 DWQ / FRO FYI and Pass Along [ ] TO: [ ] Ken Averitte _ Staff Report Recommendations [ ] [,..-1--- Belinda Henson ,------/ Complaint Investigation [ ] [ Mike Lawyer V Spill / ER Follow-up [ ] [ ] Dale Lopez Please Complete by [ ] ] Paul Rawls Please Investigate by [ ] [ ] Don Register _ Last Person, Please File [ ] [ ] Ricky Revels _ Return to [ ] [ ] Chad Turlington_ Return to Paul Rawls [ ] [ ] Hughie White