Loading...
HomeMy WebLinkAboutNC0043176_NPDES Permit Renewal_20110411s ATFA NCDENR North Carolina Department .of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director . . Secretary April 11, 2011 MEMORANDUM TO: Dina Sprinkle NPDES Unit, Point Source Branch FROM: i Mark B rantley,. Environmental Chemist _,Aesi Q Fayetteville Regional Office THROUGH: Belinda Henson, Regional Supervisor 4-144'14.t �• Surface Water Protection Section Fayetteville Regional Office SUBJECT: Major NPDES Permit Renewal Black River WWTP NPDES Permit NC0043176 Harnett County Attached is the staff report and recommendations of the Fayetteville Regional Office concerning the subject major NPDES permit renewal. Also attached are copies of the most recent inspection report dated March 2, .2006, a list of monitoring report violations from BIMS for 2009 and 2010, parameter averages from BIMS for 2009 through January 2011 as well as a facility rating sheet. If you have any questions or require further information, please contact our office. Attachments cc: Central Files Location: 225 Green Street, Suite 714. Fayetteville. North Carolina 28301 Phone: 910-433-3300 \ FAX: 910-486-0707 \ Customer Service: 1-877-623-6748 Internet: www.ncwaterqualitv.orq An Equal Opportunity Employer One NorthCarolina Naturally SOC PRIORITY PROJECT: YES_ NO X If Yes, SOC No. To: NPDES Unit, Point Source Branch Surface Water Protection Section Attention: Dina Sprinkle Date: April 7, 2011 NPDES STAFF. REPORT AND RECOMMENDATION COUNTY: Harnett Permit No. NC 0043176 PART I - GENERAL INFORMATION 1. Facility and Address: City of Dunn Black River WWTP PO Box 1065 Dunn, NC 28335 2. Date of Investigation: March 2, 2011 3. Report Prepared by: Mark Brantley, Environmental Chemist 4. Persons Contacted and Telephone Number: Mrs. Donrie Dukes, ORC 910-892-2935 5. Directions to Site: Treatment facility is located at the end of a dirt road off the south side of NCSR 1844 (Susan Tart Road), opposite from Dunn Memorial Hospital 6. Discharge Point(s), List for all discharge points: Latitude: 35° 17' 45" Longitude: 78° 38' 18" Attach a U.S.G.S. map extract and indicate treatment facility site and discharge point on map. U.S.G.S. Quad No. F-24-SW U.S.G.S. Quad Name: Erwin, NC 7. Site: Land available for expansion and upgrading: YES 8. Topography and relationship to flood plain: Basically flat with some gently sloping areas. 9. Location of nearest dwelling: Approximately 500 feet from entrance gate 10. Receiving stream or affected surface waters: Cape Fear River a. Classification: Class WS-V b. River Basin and Subbasin No.: Cape Fear River Basin 03 - 06 - 13 c. Describe receiving stream features and pertinent downstream uses: The main stem of the Cape Fear River at this point is used primarily for fish and wildlife propagation, fishing and boating. The City of Fayetteville has a water intake approximately 20 miles downstream. Access to this stretch of the river is limited. PART II - DESCRIPTION OF WASTES AND TREATMENT WORKS 1. a Volume of wastewater to be permitted: 3.75 MGD (ultimate design capacity) b. What is the current permitted capacity of the wastewater treatment facility? 3.75 MGD c. Actual treatment capacity of the current facility (current design capacity). 3.75 MGD d. Date(s) and construction activities allowed by previous Authorizations to Construct issued in the previous two (2) years. The ATC 043176A01 was issued on April 30, 2010 for converting gas chlorination/de- chlorination to a liquid chlorination/de-chlorination system. An ATC permit 043176A02 was issued on March 26, 2010 for plant upgrades. e. Please provide a description of existing or substantially constructed wastewater treatment facilities: Since the issuance of the last NPDES permit for this facility the following changes have occurred: Changes to the head works • Replacement of existing influent pump station which consisted of three screw pumps with a new influent pump station consisting of two T-10 and two T-12 Gorman Rupp pumps. • Replacement of existing automatic bar screen and grit removal units with new automatic bar screen grit removal units. • Construction of a new pump station consisting of two T-10 Gorman Rupp pumps and a three million gallon equalization tank. Changes to bio-solids handling equipment • Replacement of three blowers and aeration system in existing sludge digester • Replacement of existing Diffused Air Flotation unit with a new Rotary Drum Thickener for sludge thickening Changes to dual chlorine contact basin • Process change from gas chlorine to 12% sodium hypochlorite liquid for disinfection of effluent. • Process change from gas sulfur dioxide to sodium bisulfite liquid for de -chlorination of effluent. In addition to the changes listed above the BRWWTP continues to operate a coarse bubble activated sludge aeration basin with four cells, three final clarifiers (60 feet in diameter), dual chlorine contact basin (as described above), an effluent pump station with three vertical turbine pumps and river cascade discharge. Sludge handling facilities include aerobic digester (150,000 gallon capacity), a secondary aerobic digester/sludge holding tank (500,000 gallon capacity) and the rotary drum thickener as described above. f. Please provide a description of proposed wastewater treatment facilities: NA g. Possible toxic impacts to surface waters: NA h. Pretreatment Program (POTWs only): In development Approved Should be required Not needed X • 2. Residuals handling and utilization/disposal scheme: a. If residuals are being land applied, please specify DWQ Permit No. Permit Number WQ0006101 Residual Contractor: Synagro Telephone: b. Residuals stabilization: PSRP X PFRP Other c. Landfill: NA d. Other disposal/utilization scheme (specify): NA 3. Treatment plant classification (attach completed rating sheet): Grade IV 4. SIC Code(s): 4952 Primary 01 Secondary 23 Main Treatment Unit Code: 05003 PART III - OTHER PERTINENT INFORMATION 1. Is this facility being constructed with Construction Grant Funds or are any public monies involved (municipals only)? NA 2. Special monitoring or limitations (including toxicity) requests: No special monitoring requested. Monitoring and limits should be in keeping with basinwide strategy. 3. Important SOC, JOC, or Compliance Schedule Dates (please attach): N/A Date Submission of Plans and Specifications N/A Begin Construction - N/A Complete Construction N/A 4. Alternative Analysis Evaluation: Has the facility evaluated all of the nondischarge options available? Please provide regional perspective for each option evaluated. Spray Irrigation: NA Connection to Regional Sewer System: NA Subsurface: NA Other disposal options: NA 5. Other Special Items: None • PART IV - EVALUATION AND RECOMMENDATIONS According to some of the data and information provided in the renewal application, the City of Dunn has reduced some of their inflow and infiltration through sewer rehabilitation projects. They are also looking into the possibility of flow equalization facilities at the treatment plant and expanding the capacity of their Eastside pumping system. It is the recommendation of the Fayetteville Regional Office that the subject application for permit renewal be processed in keeping with basinwide strategy. Signature of Report reparer of Report reparer -6eLdeD 96,/nopylD Regional Supervisor, Surface Water Protection Section Date � © b NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director Secretary March 7, 2011 Ronald Autry, City Manager City of Dunn P.O. Box 1065 Dunn, NC 28335 SUBJECT: March 2, 2011 Compliance Evaluation Inspection City of Dunn Dunn WWTP Permit No: NC0043176 Harnett County Dear Mr. Autry: Enclosed please find a copy of the Compliance Evaluation Inspection form from the inspection conducted .on March 2, 2011. The Compliance Evaluation Inspection was conducted by Mark Brantley, Environmental Chemist, of the Fayetteville Regional Office. The cooperation of Mrs. Donrie Dukes, Grade IV ORC, and Mr. Gary Barefoot was greatly appreciated. The facility was found to be in Compliance with permit NC0043176. As a reminder, preservation of the Waters of the State can only be achieved through consistent NPDES Permit compliance. Comments • Construction on plant upgrades is currently ongoing. DWQ understands the following items have been installed but have not been placed into service as of the date of the inspection: new influent pump station, bar screens, grit removal system, influent flow meter, equalization tank, rotary drum thickener, and new digester blowers. • Maintenance records and logbooks are very well kept. • November 2010 laboratory bench sheets were compared to the DMR and no transcription errors were found at that time. North Carolina Division of Water Quality/Aquifer Protection Section 225 Green St./ Suite 714 Fayetteville, NC 28301 Phone (910) 433-3300 FAX (910) 486-0707 Internet: h2o.enr.state.nc.us Customer Service 1-877-623-6748 forth Carolina Naturally An Equal opportunity/Affirmative Action Employer— 50% Recycled/10% Post Consumer Paper EPA United States Environmental Protection Agency Washington, D.C. 20460 -Water Compliance Inspection Report Section A: National Data System Coding (i.e., PCS) Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 1NI 2 151 31 NC0043176 111 121 11/03/02 117 181cl 191 s1 201 1 Remarks 211IIIIIII1I11I1I1II1I III1•IlII1III IIII IIII IIIIIII" Inspection Work Days Facility Self -Monitoring Evaluation Rating 671 169 B1 QA Reserved 701 31 711 N 1 721 N 1 731 1 1 74 751 1 1 1 1 1 1 1 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Dunn WWTP Susan Tart Rd Dunn NC 28335 Entry Time/Date 10:45 AM 11/03/02 Permit Effective Date 07/02/01 Exit Time/Date 01:30 PM 11/03/02 Permit Expiration Date 11/09/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Donrie Eldridge Dukes/ORC/910-892-8162/ Name, Address of Responsible Official/Title/Phone and Fax Number Ronald D Autry,PO Box 1065 Dunn NC 28335//910-892-2633/' Contacted No Other Facility Data Section C: Areas Evaluated During Inspection (Check only those areas evaluated) ■ Permit ■ Flow Measurement ■ Operations & Maintenance MI Records/Reports III Self -Monitoring Program ■ Facility Site Review Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Mark Brantley A„,, 3 - 7-4 Agency/Office/Phone and Fax Numbers FRO WQ//910-433-3300 Ext.727/ Date Signature of Management Q A Reviewer Belinda S Henson EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Agency/Office/Phone and Fax Numbers FRO WQ//910-433-3300 Ext.726/ Date 3-7-// Page # 1 Permit: NC0043176 Owner - Facility: Dunn WWTP Inspection Date: 03/02/2011 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? • n n n Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge ■ n n n Judge, and other that are applicable?_ Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? n n • n Is the facility as described in the permit? m n n n # Are there any special conditions for the permit? n n • n Is access to the plant site restricted to the general public? ■ n n n Is the inspector granted access to all areas for inspection? ■ ❑ n n Comment: Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? • n n n Is all required information readily available, complete and current? ■ n n n Are all records maintained for 3 years (lab. reg. required 5 years)? ■ n n n Are analytical results consistent with data reported on DMRs? M n n n Is the chain -of -custody complete? ■ n n n Dates, times and location of sampling • Name of individual performing the sampling Results of analysis and calibration • Dates of analysis • Name of person performing analyses • Transported COCs ■ Are DMRs complete: do they include all permit parameters? ■ n n n Has the facility submitted its annual compliance report to users and DWQ? R n n n (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? ❑ n n Is the ORC visitation log available and current? • n n n Is the ORC certified at grade equal to or higher than the facility classification? sin i] n Is the backup operator certified at one grade less or greater than the facility classification? IN n n ❑ Is a copy of the current NPDES permit available on site? • n n n Page # - 3 Permit: NC0043176 Owner - Facility: Dunn wNTP Inspection Date: 03/02/2011 Inspection Type: Compliance Evaluation Bar Screens Yes No NA NE Are the bars adequately screening debris? ■ n n ❑ Is the screen free of excessive debris? ■ n n n• Is disposal of screening in compliance? ■ ❑ n n Is the unit in good condition? ■ n ❑ n Comment: The new bar screen has been insalled but has not been placed into service. Grit Removal Yes No NA NE Type of grit removal a.Manual n b.Mechanical ■ Is the grit free of excessive organic matter? ■ n n n Is the grit free of excessive odor? ■ n n n # Is disposal of grit in compliance? ■ n ❑ n Comment: The new grit system has been installed but has not been placed into service. Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? ■ n n n Are surface aerators and mixers operational? ❑ n ■ n Are the diffusers operational? IN n n n Is the foam the proper color for the treatment process? ■ n n ❑ Does the foam cover less than 25% of the basin's surface? ■ n n n Is the DO level acceptable? ■ n n n Is the DO level acceptable?(1.0 to 3.0 mg/I) ■ n n n Comment: De -chlorination Yes No NA NE Type of system ?. Liquid Is the feed ratio proportional to chlorine amount (1 to 1)? ■ n n n Is storage appropriate for cylinders? n n ■ n # Is de -chlorination substance stored away from chiorine containers? , n n n ■ Page # 5 Permit: NC0043176 Owner - Facility: Dunn WWTP Inspection Date: 03/02/2011 Inspection Type: Compliance Evaluation Effluent Sampling Yes No NA NE Is proper volume collected? 11111n i_I n Is the tubing clean? • n n n # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? ■ n ❑ ❑ Is the facility sampling performed as required by the permit (frequency, sampling type representative)? ■ ❑ n n Comment: Upstream / Downstream Sampling Yes No NA NE , Is the facility sampling performed as required by the permit (frequency, sampling type, and sampling location)? ❑ ❑ ■ ❑ Comment: Facility is a member of the Middle Cape Fear River Basin Association Secondary Clarifier Yes No NA NE. Is the clarifier free of black and odorous wastewater? ■ ❑ n ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? ■ ❑ n ❑ i Are weirs level? R n n n Is the site free of weir blockage? • n n n Is the site free of evidence of short-circuiting? • n 11 ❑ Is scum removal adequate? • n n f1 .Is the site free of excessive floating sludge? ■ n n n is the drive unit operational? • 0 n El Is the return rate acceptable (low turbulence)? • n 11 n Is the overflow clear of excessive solids/pin floc? R n 0 0 Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth) ■ n n n Comment: Disinfection -Liquid Yes No NA NE Is there adequate reserve supply of disinfectant? • n n 11 (Sodium Hypochlorite) Is pump feed system operational? ■ 11 ❑ ❑ Is bulk storage tank containment area adequate? (free of leaks/open drains) ■ n n is the level of chlorine residual acceptable? • n n n Is the contact chamber free of growth, or sludge buildup? ■ fl ❑ n Is there chlorine residual prior to de -chlorination? ■ ❑ ❑ n Comment: Page # 7 MONITORING REPORT(MR)'VIOLATIONS for: PERMIT: NC0043176 FACILITY: City of Dunn - Dunn WWTP COUNTY: Harnett Report Date: 03/31/11 REGION: Fayetteville Limit Violation MONITORING OUTFALL / REPORT PPI LOCATION PARAMETER 12 -2009 001 Effluent 07 -2010 001 Effluent 09 -2010 001 Effluent 02-2010 001 Effluent Chlorine, Total Residual Chlorine, Total Residual Chlorine, Total Residual Flow, in conduit or thru treatment plant VIOLATION UNIT OF DATE FREQUENCY MEASURE LIMIT 12/09/09 5 X week ug/I ' 28 29 3.57 07/16/10 5 X week ug/I 28 29 09/01/10 5 X week ug/I 28 30 7.14 02/28/10 Continuous . mgd 3.75 4.12 9.85 CALCULATED . VALUE OVER LIMIT 3.57 VIOLATION TYPE Daily Maximum Exceeded Daily Maximum Exceeded Daily Maximum Exceeded Monthly Average Exceeded VIOLATION ACTION No Action, BPJ No Action, BPJ No Action, BPJ Proceed to NOV PERMIT NUMBER: NC0043176 FACILITY NAME: City of Dunn - Dunn WWTP CITY: Dunn OUTFALL: 001 EFFLUENT COUNTY: Harnett PERIOD ENDING MONTH: 12 - 2009 REGION: Fayetteville DMR 12 Month Calculated PAGE 5 OF 7 00010 deg c Temperature, Water Deg. Centigrade 00300 mg/1 DO, Oxygen, Dissolved 00310 mg/1 BOD, 5-Day (20 Deg. C) 00400 su pH 00530 mg/1 Solids, Total Suspended 00600 mg/1 Nitrogen, Total (as N) 00610 mg/1 Nitrogen, Ammonia Total (as N) 00625 mg/1 Nitrogen, Kjeldahl, Total (as N) 1 09 14.896774 7.276 24 6.55 6.29 - 6.6 30 8.14 2.03 4 0.80665 1.65 2-09 14.107143 7.485 24 6.49 6.4 - 6.67 30 8.19 2.58 4 1.3554 1.9 3-09 14.819355 7.225455 24 7.913043 6.13 - 6.51 30 9.234783 2.48 4 0.814957 1.25 4-09 17.41 6.908095 6.19 - 6.51 2.84 5-09 20.970968 6.53 6.39 - 6.7 1.53 6-09 23.993333 6.427727 6.54 - 6.94 1.43 7-09 25.580645 6.387273 6.71 - 7.1 1.35 8-09 26.316129 6.53381 6.41 - 6.78 1.45 - 9-09 24.856667 7.041429 6.67 - 6.99 1.6 10-09 22.029032 7.447727 1 6.78 - 7.02 1.24 11-09 19.41 7.686667 6.12 - 7.01 1.09 12-09 16.303226 7.617143 6.03 - 6.7 1.4 PERMIT NUMBER: NC0043176 FACILITY NAME: City of Dunn - Dunn WWTP CITY: Dunn COUNTY: Harnett PERIOD ENDING MONTH: 12 - 2009 REGION: Fayetteville DMR 12 Month Calculated PAGE 6 OF 7 00630 mg/1 Nitrite plus Nitrate Total 1 DET. (as N) 00665 mg/1 Phosphorus, Total (as P) 31616 #/100m1 Coliform, Fecal MF, M-FC Broth,44.5C 50050 mgd Flow, in conduit or thru treatment plant 50060 ug/1 Chlorine, Total Residual C0310 mg/1 BOO, 5-Day (20 Deg. C) - Concentration C0530 mg/1 Solids, Total Suspended - Concentration C0600 mg/1 Nitrogen, Total (as N) - Concentration 1-09 3.75 0.38 0.4 10.593897 2.618677 0 2 - 09 3.75 0.68 0.45 5.244956 2.2455 0 3-09 3.75 1.23 0.6 19.911056 3.580935 0 4-09 3.75 12 30 0.42 7.319279 2.854967 0 4.966667 4.971429 3.26 5-09 3.75 12 30 1.47 9.140179 2.086419 0 4.38 4.915 3 6 - 09 3.75 12 30 0.74 37.007489 1.670267 0.909091 4.604545 5.236364 2.17 7-09 3.75 12 30 0.57 40.584668 1.923 6.045455 6.328571 5.657143 1.92 8 09 3.75 12 30 0.05 13.212475 3.356323 5.095238 4.3 6.4 1.5 9-09 3.75 12 30 1.36 17.582106 1.986967 . 0 5.052381 4.395238 2.96 10 09 3.75' 12 .30 1.93 9.950137 1.710355 9.045455 • 2.290476 3.952381 3.17 11 - 09 3.75 24 30 1.76 25.413996 2.759767 8.111111 4.021053 5.178947 2.85 12-09 3.75 24 30 0.37 . 42.668244 3.521161 6.142857 6.36 6.37 1.77 PERMIT NUMBER: NC0043176 FACILITY NAME: City of Dunn - Dunn WWTP CITY: Dunn COUNTY: Harnett CO610 mg/1 Nitrogen, Ammonia Total (as N) - Concentration C0665 mg/1 Phosphorus, Total (as P) - Concentration TGP3B pass/fail P/F STATRE 7Dax Chr Ceriodaphnia 1 - 09 2-09 3-09 1 2 4-09 1.439333 0.2 2 5-09 1.1025 0.9 2 6-09 0.698273 0.6 1 2 7-09 0.793333 0.3 2 8-09 0.666909 0.7 2 9-09 0.319714 1.2 1 2 10-09 0.199238 1.9 4 11 - 09 0.723526 0.8 4 12-09 1.0275 0.1 1 PERIOD ENDING MONTH: 12 - 2009 REGION: Fayetteville DMR 12 Month Calculated PAGE 7 OF 7 4 PERMIT NUMBER: NC0043176 FACILITY NAME: City of Dunn - Dunn WWTP CITY: Dunn OUTFALL: 001 EFFLUENT COUNTY: Harnett PERIOD ENDING MONTH: 12 - 2010 REGION: Fayetteville DMR 12 Month Calculated ti PAGE 5 OF 6 00010 deg c Temperature, Water Deg. Centigrade 00300 mg/1 DO, Oxygen, Dissolved . 00900 su pH 00625 mg/1 • Nitrogen, Kjeldahl, Total (as N) 00630 mg/1 Nitrite plus Nitrate Total 1 DET. (as N) 31616 #/100m1 Coliform, Fecal MF, M-FC Broth,99.5C 50050 mgd Flow, in conduit or thru treatment plant 50060 ug/1 Chlorine, Total Residual 1 10 3.75 13.219355 7.899474 • 6.14 - 6.77 3.01 0.69 10.048643 3.44729 7.894737 2-10 • 3.75 12.228571 7.6335 6.19 - 6.71 1.03 0.96 20.593137 4.1195 Violation 5.45 3-10 3.75 13.987097 7.703043 6.38 - 6.76 . 2.52 0.23 18.765476 3.721871 5.521739 4-10 3.75 17.72 7.4 6.44 - 6.94 2.23 1 6.638646 2.498 0 5 - 10 3.75 21.43871 7.231 6.7 - 7 1.59 1.21 .7.966901 1.834548 2 6 10 3.75 25.046667 6.734545 6.85 - 7.11 3.42 0.27 20.601104 1.690333 4.863636 7-10 • 3.75 27.1645161 6.602381 6.87 - 7.2 1.56 0.61 36.52381 1.5092226 3.3809524 8 - 10 3.75 27.5548387 6.6209091 6.63 - 7.1.6 1.74 1.73 17.045455 1.7089645 12 9-10 3,75 26.2566667 7.0733333 6.44 - 7.03 1.21 2.53 19.285714 1.7236033 12.8095238 10-10 3.75 23.0096774 7.3738095 6.34 - 6.84 0.98 5.09 19.714286 2.2056548, 3.047619 11 10 3.75 19.0966667 7.1268421 6.41 - 6.86 1.26 6.9 4.421053 1.6548833 1.1052632 12-10 3.75 14.3451613 6.812381 6.09 - 6.7 1.1 9.16 7.6 1.7086323 1.15 PERMIT NUMBER: NC0043176 FACILITY NAME: City of Dunn - Dunn WWTP CITY: Dunn COUNTY: Hamett PERIOD ENDING MONTH: 12 - 2010 REGION: Fayetteville C0310 mg/1 BOD, 5-Day (20 Deg. C) - Concentration C0530 mg/1 Solids, Total Suspended - Concentration C0600 mg/1 Nitrogen, Total (as N) - Concentration C0610 mg/1 Nitrogen, Ammonia Total (as N) - Concentration C0665 mg/1 Phosphorus, Total (as P) - Concentration TGP3B pass/fail P/F STATRE 7Day Chr Ceriodaphnia 24 30 4 1-10 5.52 6 3.7 0.78915 0.2 24 30 4 2-10 8.18 6.75 1.99 1.32575 0.4 . 24 30 4 3-10 8.273913 8.091304 2.75 1.377043 0.3 1 12 '30 2 4-10 5.865 5.78 3.23 0.7383 0.4 12 30 2 5-10 5.033333 4.904762 2.8 0.617 0.8 12 30 2 6-10 5.086364 5.55 3.69 0.641591 2 1 12 30 2 7-10 5.215 8.57 2.17 0.3585 3.4 . 12 30 2 8-10 6.1217391 8.2869565 3.47 0.61 0.6 12 30 2 9-10 5.6095238 6.4571429 3.74 0.1014286 1.2 1 12 30 2 10-10 3.2380952 6.5333333 6.07 0.087619 1.3 24 30 4 11-10 3.5157895 5.0526316 8.16 0.0226316 1.5 24 30 4 12-10 4.2315789 6.4947368 10.26 0.0063158 1.3 1 DMR 12 Month Calculated PAGE 6 OF 6 » n