Loading...
HomeMy WebLinkAboutWQ0000889_Monitoring - 12-2020_20210203FORM: NDMR 05-16 NON -DISCHARGE MONITORING REPORT (NDMR) Page 1 of 2 Permit No.: W00000889 Facility Name: PCS Phosphate WWTP County: Beaufort Month: December Year: 2020 PPI: 001 Influent [] Effluent - No flow generated Parameter Monitoring Point: Influent Effluent _ Groundwater Lowering _ Surface Water Parameter Code - ► 50050 00310 00940 50060 31616 00610 00625 00620 00600 00400 00665 70300 00530 • O E Of O N E ; UN Q o V. p N U d t W U E O U o Q Z - Z Tcc td0. 0 }0 2 a y U) S ;° vo e can U)CIO 24-hr hrs GPD mg/L mg/L mg/L #/100 mL mg/L mg/L mg/L mg/L su mg/L mg/L mg/L 1 08:00 8.5 13,900 <2.0 <1 <0.04 1.15 22.4 23.55 7.52 5.12 <2.5 2 08:00 8.5 13,100 7.28 3 08:00 8.5 10,500 7.25 4 08:00 8.5 13,800 7.17 5 13,149 6 13,149 7 08:00 8.5 13,149 7.41 8 08:00 8.5 12,100 7.35 9 08:00 8.5 11,835 7.3 10 08:00 8.5 1 6,065 7.36 11 08:00 8.5 19,000 7.41 12 13,167 13 13,167 141 08:00 8.5 13,167 7.2 15 08:00 8.5 16,100 7.2 16 08:00 8.5 13,330 7.12 17 08:00 8.5 16,710 7.13 18 08:00 8.5 F 10,090 72 19 12067 20 12067 21 0800 8.5 12067 7.36 22 08:00 8.5 10400 7.39 23 08:00 8.5 17800 7.41 24 ', 12440 Holidav 25 -- 12440 Holiday 26 12,440 27 12,440 28 08:00 8.5 12,440 7.33 29 08:00 8.5 13,080 7.4 30 08:00 8.5 11,353 7.5 311 08:00 8.5 10,945 7.49 Average: 12,821 0.00 1.00 0.00 1.15 22.40 23.55 5.12 0.00 Daily Maximum: 19,000 2.00 1.00 0.04 1.15 22.40 23.55 7.52 5.12 2.50 Daily Minimum: 6,065 2.00 1.00 0.04 1.15 22.40 23.55 7.12 5.12 2.50 Sampling Type: Recorder Composite Composite Grab Grab Composite Composite Composite Composite Grab Composite Composite Composite Monthly Limit: 30,000 10 1 200 1 4 1 5 Daily Limit: 1 15 1 16i 1 6-9 10 Sample Frequency:1 Continuous I Monthly 3 X Year Per Event I Monthly I Monthly Monthly Monthly IMonthly 1 5 X Week Monthly 3 X Year Monthly FORM: NDMR 05-16 NON -DISCHARGE MONITORING REPORT (NDMR) Page _2_ of _2_ Sampling Person(s) 11 Certified Laboratories Name: Larry D. Davis, Jr. Name: Environment One, Incorporated Id. 10 Name: Name: PCS Phosphate Inc. Id 330 Does all monitoring data and sampling frequencies meet the requirements in Attachment A of your permit? 0 Compliant ❑ Non -compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additional sheets if necessary. Operator In Responsible Charge (ORC) Certification Permittes Certification ORC; Larry D. Davis, Jr. Permittee: PCS Phosphate Inc. Certification No.: 1004832 Signing official: William Ponton Grade: WW IV Phone Number: 252-322-8111 ext 8642 Signing Officials Title: General Manager Has the ORC changed since the previous NDMR? ❑ yes Q No Phone Number: (252) 322-8283 Permit Expiration: 3/31/2022 ZY22- 2 ` �— //27/ 242-/ Sigirrature Date Signature Date By this signature, I certify that this report is accurate and complete to the best of my Imowlodge. I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision In accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mall Service Center Raleigh, North Carolina 27699-1617 FORM: NDAR-2 05-16 NON -DISCHARGE APPLICATION REPORT (NDAR-2) Page 1 of 2 Permit No.: WQ0000889 Facility Name: PCS Phosphate WWTP County: Beaufort Month: December Year: 2020 Did infiltration occur at this facility? YES No Site Name: 1 Site Name: 2 Site Name: 3 Site Name: Area (acres): 0.15 Area (acres): 0.15 Area (acres): 0.15 Area (acres): 2 Rate (GPD/ft ): 4.99 Rate (GPD/ft2): 4.99 Rate (GPD/ft2): 4.99 Rate (GPD/ft2): Weather Freeboard Site Infiltrated? [ YES [ NO Site Infiltrated? [ YES NO Site Infiltrated? [ YES ❑ NO Site Infiltrated? _ YES ❑ NO oT 'p LUdv 3 E C d y .00 R o CL a ao D 0 a y E o a > o i S 6 O J 72 C ° O aH � y =d oa % p) : O O N 'p � y E J �Om y �d dY EEY S �.S° `°Oa J 1 OO °� CH�_Nf6 LLm 3 °F in ft ft gal min GPD/ft2 ft gal min GPD/ft2 ft gal I min GPD/ft2 ft gal min GPD/ft2 ft 1 C 52 0 13,900 312 2,13 2 C 49 0 13,100 306 2.00 3 C 57 0 10,500 234 1.61 4 C 70 0.13 13,800 318 2.11 5 64 0.06 13,149 272 2.01 6 52 0 13,149 272 2.01 7 R 50 0.08 13,149 272 2.01 8 C 45 0 12,100 272 1.85 9 PC 52 0 11,885 252 1.82 10 PC 56 1 0 6,065 240 0.93 III PC 66 0 19,000 120 2.91 12 67 0 1 13,167 300 2.02 13 69 0.07 13,167 300 2.02 14 CL 70 0.52 13,167 300 2.02 15 CL 46 0.39 1 13,167 330 2.02 16 R 62.1 0 16,100 276 2.46 171 PC 43 0.7 13,300 348 2.04 18 C 44 1 0.01 16,710 210 2.56 19 45 0 10,090 254 1.54 20 45 0 12,067 254 1.85 21 CL 45 0.65 12,067 254 1.85 22 C 44 0.03 12,067 254 1.85 23 C 54 0 10,400 222 1.59 24 Holiday 1 17,800 372 2.72 25 Holiday 12,440 296.4 1.90 26 41 0 12,440 296.4 1.90 27 39 0 12,440 296.4 1.90 281 C 46 0 12,440 296.4 1.90 29 C 60 0.92 13,080 282 2.00 30 C 49 0 11,353 234 1.74 31 C 63 0 10,945 380 1.68 ! Monthly Loading (GPD/ft): Year to Date Loading GPD/ft2 : 1.98 1.95 FORM: NDAR-2 05-16 NON -DISCHARGE APPLICATION REPORT (NDAR-2) Page 2 of 2 Did the application rates exceed the limits in Attachment B of your permit? If not a basin, were the sites kept free of vegetation and raked? If not a basin, were there any instances of effluent ponding in or runoff from the sites? El Compliant ❑ Non -Compliant R1 Compliant ❑ Non -Compliant Q Compliant Non -Compliant If a basin, were there any instances of breakout from the berms? ❑r Compliant ❑ Non -Compliant Was the onsite automatically activated standby power source tested and operational? R1 Compliant ❑ Non -Compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the dates) of the non-compliance and describe the corrective actionfSl taken. Attach ariclitinnal chaate if narccc— Operator in Responsible Charge (ORC) Certification Permittee Certification ORC: Laity D Davis Jr. Permittee: PCS Phosphate Certification No.: 1004832 Signing Official: William Ponton Grade: WW IV Phone Number: (252) 322-8111 ext. 8642 Signing Official's Title: General Manager Has the ORC changed since the previous NDAR-2? ❑ Yes 0 No Phone Number: (252)322-8283 Permit Exp.: 3/31/22 7,' 0,jV -Z7-2-ti 71�VZ/ Signature Date Signature Date By this signature. I certify that this report is accurrate and complete to the best of my knowledge. I certify, under penalty of law, that this document and all atwi necks were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and avalueted the informatkxr submitted. Based on my Inquiry of the person or persons who manage the system, or those persons directly responslble for gathering the information, the information submitted Is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant Penalties for submitting false Information, Including the possibility of fines and imprisonment for knowing violations, Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617