Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NC0043176_Inspection_20081119
o -- ,9/ Or" QjCO 7 Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality Ronald D Autry City of Dunn PO Box 1065 Dunn NC 28335 November 19, 2008 SUBJECT: November 12, 2008 Compliance Evaluation Inspection City of Dunn Dunn WWTP Permit No: NC0043176 Harnett County Dear Mr. Autry: Enclosed please find a copy of the Compliance Evaluation Inspection form from the inspection conducted on November 12, 2008. The Compliance Evaluation Inspection was conducted by Mark Brantley, Environmental Chemist, of the Fayetteville Regional Office. The time and cooperation of Dean Gaster, Public Utilities Director, Donrie Dukes, Facility's Grade IV ORC, and Gary Barefoot, Grade II Operator, was greatly appreciated. The facility was found to be in Compliance with permit NC0043176. As a reminder, preservation of the Waters of the State can only be achieved through consistent NPDES Permit compliance. Comments • Facility was clean and neat in appearance at the time of the inspection. The facility appears to be maintained well and several positive operational changes have been made to make the plant run more efficiently. However, the Division of Water Quality does not, agree with the practice of storing chlorine gas and sulfur dioxide gas in the same area because of a public safety concern and the safety of plant personnel. Currently these gases are stored in one -ton cylinders at the WWTP. If one of these tanks were to rupture a significant area would be impacted such as the area hospital, surrounding medical area, and the possible closure of several main highways. The division has noted this in inspections during the past few years. During the inspection Mr. Dean Gaster stated that the city was in the planning stages for switching to liquid bleach for chlorination and a liquid dechlorination agent for dechlorination. The Fayetteville Regional Office strongly supports this action and encourages the City to • move forward with these plans as quickly as possible. By switching td a liquid chlorination/dechlorination system the City would be taking a proactive step in ensuring the safety of its citizens and plant personnel. Please note that safety precautions must be taken with liquid system but the danger with this system is significantly less than the dangers associated with the current gas system. • It was noted during the inspection that this facility is not covered under a NPDES General Stormwater Permit (NCG110000 series). Since this facility is permitted for more than a million gallons per day flow and it has a point source discharge for stormwater it is necessary to apply for a NPDES General Stonnwater Permit. Enclosed is an application for the permit along with its technical bulletin that contains some useful information. Please submit a completed application no later than December 15, 2008. —North Carolina Division of Water Quality/Aquifer Protection Section 225 Green St./ Suite 714 Fayetteville, NC 28301 Phone (910) 433-3300 FAX (910) 486-0707 Internet: h2o.enr.state.nc.us Customer Service 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer— 50%Recycled/10% Post Consumer Paper One NorthCarolina 7atill"al y Please refer to the enclosed inspection report for additional observations and comments. If you or your staff have any questions, please call me at 910-433-3300 ext.727. Sincerely, )itemA Mark Brantley Environmental Chemist Surface Water Protection Section Fayetteville Regional Office cc: Dean Gaster, Public Utilities Director Donrie Eldridge Dukes, ORC Central Files Fayetteville Files United States Environmental Protection Agency. E p A Washington, D.C. 20460 f�/`1 • Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) • Transaction Code NPDES yr/mo/day Inspection 1 INI •2 151, 31 NC0043176 '1.11 121 08/11/12 1'17 Type Inspector Fac Type 181CI ". 191sr 201 I LJ I. I I •:1 I 1 I. 11 I I I I I 1 Remarks 211, III 1 I I I I I 1 I I I I I I I I I I I 1 '1 I'1 I I I I I .166 Inspection Work Days • Facility Self -Monitoring Evaluation Rating B1 - QA Reserved 74 79 III 1 1 I, 80 671 1. 169 701 31 711 NI 721 NI 731 1 1 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) . Dunn WWTP Susan Tart Rd - Dunn NC 28335 • Entry Time/Date 09:45 AM 08/11/12 Permit Effective Date 07/02/01 Exit Time/Date 12:00 PM 08/11/12 Permit Expiration Date 11/09/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) '/// Donrie Eldridge Dukes/ORC/910-892-8162/ Other'Facility Data . Name, Address of Respohsible Official/Title/Phone and Fax Number Contacted Ronald D Autry, PO Box.1065 Dunn -NC 28335//910-892-2633/ .No Section C: Areas Evaluated During Inspection.(Check only those areas evaluated) Permit • Flow Measurement Operations & Maintenance • Records/Reports Self -Monitoring Program • Sludge Handling Disposal -. Facility Site Review Section D: Summary of Finding/Comments (Attach' additional sheets of narrative and chedklists as necessary) (See attachment summary) . Name(s) and Signature(s) of Inspector(s) . Agency/Office/Phone and Fax Numbers Date Mark Brantley • FRO WQ//910-433-3300 Ext.727/ /4144/4( Aelt447--- • / I -11 •eik Signature of Management Q A Reviewer 0 Agency/Office/Phone and Fax Numbers Date Belinda S Henson ��� .QA, r �7 p FRO WQ//910-433-3300 Ext.726/ 11- 1 (-0S • EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page # 1 NPDES yr/mo/day Inspection Type 31 NC0043176 /11 121 08/11/12 I17 18ICI 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Page # 2 7 Permit: NC0043176 Owner - Facility: Dunn WWTP Inspection Date: 11/12/2008 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? © n n n . Does.the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge ■ n n n Judge, and other that are applicable? Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee, submitted a new application? n n ■ n Isthe facility as described in the permit? ■ ❑ ❑ ❑ #.Are there any special conditions for the permit? ❑ ❑ ■ ❑ Is access to the plant site restricted to the general.public? ■ nnn. Is the inspector granted access to all areas for inspection? • n , ❑ ❑ Comment: Record Keeping Are records kept and maintained as required by the permit? Is all required information readily available, complete and current?, Are all records maintained for 3 years (lab. reg. required 5 years)? Are analytical results consistent with data reported on DMRs? Is the chain -of -custody complete? Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete:7do they ,include all permit parameters? Has the facility submitted its annual.compliance report to users and DWQ? Of the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a `certified operator on. each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Yes No NA NE ■nnn ■ nnn ■ nn,n n nn■ n nn■ n n n' n n , ■•nnn ■ nnn .nn■n ■ nnn_ ■nnn • ■ nnn. ■ nnn Page # . 3 Permit: NC0043176 Owner - Facility: Dunn WWTP Inspection Date: 11/12/2008 Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Facility has copy of previous year's Annual Report on file for review? Erin n Comment: Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? ■ n n n Is flow meter calibrated annually? • n n n Is the flow meter operational? is ❑ n n (If units are separated) Does the chart recorder match the flow meter? n n ❑ L Comment: Flow meter was last calibrated on April 23, 2008. Aerobic Digester Yes No NA NE Is the capacity adequate? ■ n n n Is the mixing adequate? • n n n Is the site free of excessive foaming in the tank? ■ n n n # Is the odor acceptable? ■ ❑ n n # Is tankage available for properly waste sludge? ■ n n n Comment: Solids Handling Equipment Yes No NA NE Is the equipment operational? ■ n n n Is the chemical feed equipment operational? • El ❑ n Is storage adequate? • n n n Is the site free of high level of solids in filtrate from filter presses or vacuum filters? ❑ ❑ • n Is the site free of sludge buildup on belts and/or rollers of filter press? n n ■ n Is the site free of excessive moisture in belt filter press sludge cake? n n ■ n The facility has an approved sludge management plan? ■ n n n Comment: Pump Station - Effluent Yes No NA NE Is the pump wet well free of bypass lines or structures? ■ n n ❑ Are all pumps present? ■ n n n Are all pumps operable? ■ n n n Are float controls operable? ■ n n n Is SCADA telemetry available and operational? • ❑ ❑ ❑ Page # 4 Permit: NC0043176 Owner - Facility: Dunn WWTP Inspection Date: 11/12/2008 Inspection Type: Compliance Evaluation Pump Station - Effluent Is audible and visual alarm available and operational? Comment: Yes No NA NE nr0■ Pump -Station - influent Yes. No NA 'NE Is the pump wet well free of bypass lines or structures? - ■ n n n Is the wet well free of excessive grease? ■ n n n Are all pumps present? , ■ n. n n Are all pumps operable? . ■ n n n Are float controls operable? • n n n • Is SCADA telemetry available.and operational? . ❑ fl • ❑ Is audible and visual alarm available and operational? ■ ❑ .❑ Comment: Bar Screens Yes No- NA NE Type of bar screen a.Manual ■ b.Mechanical ■ Are the bars'adequately screening debris? ■ n n n Is the screen free of excessive debris? .. 'Finn Is disposal of screening in compliance? - . ■ n 0 ❑. Is the unit in good condition? - ■ n n n Comment: Grit Removal Yes •No NA NE Type of grit removal a.Manual b.Mechanical ■ Is the grit free of excessive organic matter? ■ n n n • Is the grit free of excessive odor? ■ n n n # Is disposal of grit in compliance? - ■ ❑ n n Comment: - Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? ■ n n .n • Page # 5 Permit: NC0043176 Owner - Facility: Dunn WWTP Inspection Date: 11/12/2008 Inspection Type: Compliance Evaluation Secondary Clarifier Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately'/< of the sidewall depth) Comment: Aeration Basins Mode of operation Type of aeration system Is the basin free of dead spots? Are surface aerators and mixers operational? Are the diffusers operational? Is the foam the proper color for the treatment process? Does the foam cover less than 25% of the basin's surface? Is the DO level acceptable? Is the DO level acceptable?(1.0 to 3.0 mg/I) Comment: Disinfection -Gas Are cylinders secured adequately? Are cylinders protected from direct sunlight? Is there adequate reserve supply of disinfectant? Is the level of chlorine residual acceptable? Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de -chlorination? Yes No NA NE ■ nnn ■ nnn ■ nnn ■ nnn ■ nnn ■ nnn ■ nnn Ennn ■ nnn ■ nnn Yes No NA NE Ext. Air Diffused ■nnn nn■n ■ nnn ■ nnn ■ nnn. ■ nnn ■ nnn Yes No NA NE ■ nnn Ennn ■ .nnn ■ nnn ■ nnn ■ nnn Page # 6 Permit: NC0043176 Inspection Date: 11/12/2008, Owner - Facility: Dunn WWTP " 2 Inspection Type: Compliance Evaluation Disinfection -Gas Does the Stationary'Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)? If yes, then is there a Risk Management Plan on site? If yes, then what is the EPA twelve digit ID Number? (1000, ) If yes, then when was the RMP last updated? Comment: De -chlorination Type of system ? Is the feed ratio proportional to chlorine amount (1 to 1)? Is storage appropriate for cylinders? # Is de -chlorination substance stored away from chlorine containers? Are the tablets the proper size and type? Comment: Chlorine tanks and sulfur dioxide tanks are stored in the same building. Are tablet de -chlorinators operational? Number of tubes in use? - Comment: Standby Power Is 'automatically activated standby power available? Is the generator tested by interrupting primary power source? • Is the generator tested under load? Was generator tested & operational during the inspection? Do the generator(s) have adequate capacity to operate the entire wastewater site? Is there an emergency agreement with a fuel vendor for extended run on back-up power? Is the generator fuel level monitored? - Comment: Pumps-RAS-WAS Are pumps in place? Are pumps operational? - Are there adequate spare parts and supplies on site? Comment: Influent Sampling Yes :No NA NE ■ n.nn ■ nnn Yes No NA NE • Gas ■ nnn florin nrion nn■n Yes No NA NE ■ nnn ■ nnn ■ nnn _nnn■ ■ nnn nnn.■ ■ nnn Yes ' No NA NE ■ nnn nnn' ■ nnn Yes No NA NE Page # 7 Permit: NC0043176 Owner - Facility: Dunn WWTP Inspection Date: 11/12/2008 Inspection Type: Compliance Evaluation Influent Sampling Yes No NA NE # Is composite sampling flow proportional? n n ■ n Is sample collected above side streams? ■ n n n Is proper volume collected? • n n n Is the tubing clean? • n n ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? ■ n n n Is sampling performed according to the permit? • n ❑ ❑ Comment: The influent sampler temperature was at 3 degrees celsius at the time of the inspection. Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ■ n ❑ n Is sample collected below all treatment units? • n n n Is proper volume collected? • n n n Is the tubing clean? ■ n n n # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? • n n Is the facility sampling performed as required by the permit (frequency, sampling type representative)? ■ n n n Comment: Upstream / Downstream Sampling Yes No NA NE Is the facility sampling performed as required by the permit (frequency, sampling type, and sampling location)? n n ■ n Comment: Facility is a member of the Cape Fear River Basin association. Page # 8 FOR AGENCY USE ONLY A NCDENR %I9H G,+c Una 0.ra'nnevr sb r,v,-ty KF.'(T Avo Nntr ,. RF50,1:F.ts Division of Water Quality / Water Quality Section National Pollutant Discharge Elimination: System NCG110000 Date Received Year Month Day Certificate of Coverage NICIGI'I I I] Check # • Amount Permit A sinned to NOTICE OF INTENT National Pollutant Discharge Elimination System application for, coverage under General Permit' NCG110000: STORMWATER DISCHARGES associated with activities classified as: Treatment Works treating domestic sewage or any other sewage sludge or Wastewater treatment device or system, used in the storage, treatment, recycling, and reclamation of municipal or domestic sewage, with a design flow of 1.0 million gallons per day or more, or required to have an approved pretreatment program under Title 40Code of Federal Regulations (CFR) Part 403, including lands dedicated to the disposal of sewage sludge that is•located within the confines'of the facility; and like activities‘deemed by DWQ to be similar in the' process and/or the exposure of raw materials, products, by-products, or waste 'materials. (Please print or type) 1,) Mailing address of owner/operator (address to which all permit correspondence will be mailed): Name Street Address City State •ZIP Code Telephone No. Fax: E-mail Address 2) Location of facility producing discharge: Facility Name Facility Contact Contact E-mail Street Address City State ZIP Code County Telephone No. Fax: 3) Physical Location':Information:. Please provide a narrative description of how.to get to the facility (use streetnames, state road numbers, and distance and direction from a roadway intersection). (A copy of a county map or USGS quad sheet with facility clearly located, on the map is required to be submitted with this application) 4) Latitude - Longitude ' (degrees, minutes, seconds) 5) This NPDES Permit Application applies to which of the following : ❑ New or Proposed Facility Date operation is to begin ❑ Existing Page 1 'of 4 SWU-226-071408 •. Last Revised 7/14/2008 NCG110000 N.O.I. 6) Standard Industrial Classification: Provide the 4 digit Standard Industrial Classification Code (SIC Code) that describes the primary industrial activity at this facility SIC Code: 7) Provide a brief narrative description of the types of industrial activities and products manufactured at this facility: 8) Discharge points / Receiving waters: How many discharge points (ditches, pipes, channels, etc.) convey stormwater from the property? 9) Receiving waters: What is the name of the body or bodies of.water (creek, stream, river, lake, etc.) that the facility stormwater discharges end up in? If the site stormwater discharges to a separate storm sewer system, name the operator of the separate storm sewer system (e.g. City of Raleigh municipal storm sewer). 10) Does this facility have any other NPDES permits? ❑ No ❑ Yes If yes, list the permit numbers for all current NPDES permits for this facility: 11) Does this facility have any Non -Discharge permits (ex: recycle permits)? ❑ No ❑ Yes If yes, list the permit numbers for all current Non -Discharge permits for this facility: 12) Does this facility employ any best management practices for stormwater control? ❑ No ❑ Yes If yes, please briefly describe: 13) Does this facility have a Stormwater Pollution Prevention Plan? ❑ No ❑ Yes If yes, when was it implemented? 14) Are vehicle maintenance activities occurring at this facility? ❑ No ❑ Yes 15) Hazardous Waste: a) Is this facility a Hazardous Waste Treatment, Storage, or Disposal Facility? ❑ No ❑ Yes Page 2 of 4 SWU-226-071408 Last Revised 7/14/2008 NCG110000 N.O.I.. b) Is this facility a Small Quantity Generator (less than 1000 kg. of hazardous waste generated per month) of hazardous waste? ❑ No ❑ Yes c) Is this facility a Large Quantity Generator (1000 kg. or more of hazardous waste generated per month) of hazardous waste? ❑ No ❑ Yes d) If you answered yes to questions b. or c., please provide the following information: Type(s) of waste: How is material stored: Where is material stored: How many disposal shipments per year: Name of transport / disposal vendor: Vendor address: 16) Certification: North Carolina General Statute 143-215.6 b (i) provides that: Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan, or other document filed or required to be maintained under this Article or a rule implementing this Article; or who knowingly makes a false statement of a material fact in a rulemaking proceeding or contested case under this Article; or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under this. Article or rules of the =[Environmental Management] Commission implementing this Article shall.be guilty of a Class 2 misdemeanor which may include a fine not to , exceed ten thousand dollars ($10,000). I hereby request coverage under the referenced General Permit. I understand that coverage under this permit will constitute the permit requirements for the discharge(s) and is enforceable in the same manner as an individual permit. I certify that I am familiar with the information contained in this application and that to the best of my knowledge and belief such information is true, complete, and accurate. Printed Name of Person Signing: Title: (Signature of Applicant) (Date Signed) Notice of Intent must be accompanied by a check or money order for $100.00 made payable to NCDENR Page 3 of 4 S W U-226-071408 Last Revised 7/14/2'008 NCG110000 N.O.I. Final Checklist This application will be returned as incomplete unless all of the following items have been included: ❑ Check for $100 made payable to NCDENR ❑ This completed application and all supporting documents ❑ Copy of county map or USGS quad sheet with location of facility clearly marked on map Mail the entire package to: Stormwater and General Permits Unit Division of Water Quality 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Note The submission of this document does not guarantee the issuance of an NPDES permit. For questions, please contact the DWQ Central Office or Regional Office for your area. DWQ Regional Office Contact Information: Asheville Office (828) 296-4500 Fayetteville Office (910) 433-3300 Mooresville Office (704) 663-1699 Raleigh Office (919) 791-4200 Washington Office ...(252) 946-6481 Wilmington Office (910) 796-7215 Winston-Salem (336) 771-5000 Central Office (919) 807-6300 I Wilmington Page 4 of 4 SWU-226-071408 Last Revised 7/14/2008 North Carolina Department of Environment and Natural Resources Technical Bulletin for N.C. General Stormwater Permits NCGO5, 07,.1.1, & 13 Technical Bulletin for NCG050000/ 070000/ 1 10000/ 130000, Volume IV Last Revised 5/ 15/2008 What activities are covered by these general permits? NCG050000 allows stormwater discharges. associated with activities classified as establish- ments primarily engaged in: Apparel and other . finished products made from fabrics and similar materials [standard industrial classification (SIC) 23]; Printing, publishing, and allied industries [SIC 27]; Converted paper and paperboard prod- ucts [SIC 267];; Paperboard containers and boxes [SIC 265]; Miscellaneous manufacturing industries [SIC 39]; Leather and leather products [SIC 31]; and Rubber and miscellaneous products [SIC 30]; and similar activities (see permit.), Excluded: Leather tanning and finishing [SIC 311] and Tires and inner tubes [SIC 301]. NCG070000 allows stormwater discharges associated with activities classified as establish- ments primarily engaged in:. Stone, Clay, Glass, and Concrete Products [standard industrial classi- fication (SIC) 32]; similar activities. Excluded: Ready -mixed concrete [SIC3273] and Hydraulic Cement [SIC 3241]. NCG110000 allows stormwater discharges associated with 'activities classified as Treatment Works treating domestic sewage or any other sewage sludge or wastewater treatment device or system, used in the storage, treatment, recycling, and recla mation of municipal or domestic sewage, with a design flow of 1.0 million gallons per day or more, or facilities which are required to have an approved pretreatment program under Title 40 CFR §403, including lands dedicated to the disposal of sewage sludge that is lo- cated within the confines of the facility. ' NCG130000 allows stormwater discharges associated with activities classified as establishments primarily engaged in: wholesale trade of non-metal waste and scrap (hereafter referred to as the non- metal waste recycling industry, a portion of standard industrial classification (SIC) 5093); similar activities. Excluded: wholesale trade of metal waste and scrap, iron and steel scrap, and nonferrous metal scrap; waste oil recycling; and automobile wrecking for scrap. . What does this permit require me to do? Key Permit Requirements • Implement a Stormwater Pollu- tion Prevention Plan (SPPP) (Part II, Section A). • Provide secondary containment for all bulk storage of liquid mate- rials. (Part II, Section A, 2.(b)). • Perform and document semi- annual qualitative monitoring during a representative storm event. (Part II, Section B). Perform semi-annual analytical monitoring for vehicle mainte- nance area, if present, and submit • the results on the monitoring re- ' port forms provided with the per- mit. (Part II, Section C). ' What are BMPs, and why are they important? The SPPP should include the use of Best Management Practices (BMPs) to. control discharge of pollutants from a facility's stormwater out - .falls. BMPs include a variety of things that the industrial facility can do to minimize the potential for pollutants to get into the stormwa- ter draining from a facility. There are different types of BMPs: Non -Structural BMP's Non-structural (practices or activi- ties) BMPs include: * Eliminate exposure of materials and equipment wherever possible by moving materials and equip- ment to indoor locations. * Practice good housekeeping on - site. Keep materials handled and stored atthe facility in an orderly fashion. ' * Exchange hazardous materials for non -hazardous ones wherever possible: '* Establish routine leak and main- tenance checks to minimize the chance of spills before they occur. PAGE 2 TECHNICAL BULLETIN FOR N.C. GENERAL STORMWATER PERMITS NCGOS, 07, I I, & 13 LAST REV. 5/15/08 What does this permit require me to do? (continued) When spills occur, clean them up immediately. * Establish bulk storage tank protocols that minimize the risk of spills during -loading and unload- ing procedures. * Store used pallets and process waste dumpsters inside or under a roof where water cannot flow on or around them. Structural BMPs Structural (equipment or devices) BMPs include: * Build containment dikes around the loading areas of bulk liquid storage containers. * If practical, change painting op- erations from liquid systems to powdered systems that do not Could 1 monitor at fewer outfalls? All outfalls associated with vehi- cle maintenance must be moni- tored. However, the facility may request approval of "Represent- ative Outfall Status." This status allows analytical monitoring at fewer outfalls. To request repre- sentative outfall status, send a letter to the DWQ Regional Office explaining which outfall(s) can be considered representative of other discharges and include all neces- sary supporting documentation. Where can I find more information? Additional information is avail- able at our website (see right). Another valuable source is the Division of Pollution Prevention and Environmental Assistance. The DPPEA has specific informa- tion about how to minimize pol- lutants at various industries. Call (919) 571-4100 or visit generate solvent wastes. * Build roofs and secondary con- tainment around materials stored outside where stormwater cannot contact them. Could I be exempted from an NPDES stormwater permit? Possibly. A facility with any indus- trial activity subject to the NPDES Stormwater regulations that elimi- nates all potential stormwater ex- posure may be eligible for a No Ex- posure Exclusion from a stormwa- ter permit. A facility that meets this condition may submit a No Ex- posure Certification application form (see NC DWQ's Stormwater Do I need a certified lab to analyze stormwater. samples? Monitoring under all NPDES per- mits must be conducted in accor- dance with test procedures ap- proved under federal regulations in 40 CFR §136. All labs certified by North Carolina perform analysis in accordance with those procedures. While N.C. certification require- ments do not apply to stormwater only discharges, any data gathered under an NPDES permit must con- form to federal requirements. Us- ing a certified lab is one way to en - Permitting Unit's website: ) to apply for a No Exposure Exclu- sion. The facility must re- certify No Exposure every five (5) Years. What if I sell my business, or the name of my business changes? This change is a minor modifica- tion and requires the Director's approval. You should complete the Name/Ownership Change Form SWU-239. This form is downloadable from our website, sure compliance with these re- quirements. A list of certified labs is available from: i'ti ,:.'1;_'_, :..; • Note that pH is a field parameter and must be measured within 15 minutes. You must either train on -site staff to measure pH in accordance with approved methods or contract with commer- cial services. All entities with field parameter certification as per 15A NCAC 2H .0800 can ana- lyze pH in accordance with federal procedures (see website for list). Who can help me with questions? Your questions about stormwater permit requirements can be addressed to the Division of Water Quality Offices: Asheville Office (828) 296-4500 Washington Office (252) 946-6481 Fayetteville Office (910) 433-3300 Wilmington Office (910) 796-7215 Mooresville Office (704) 663-1699 Winston-Salem Office.... (336).771-5000 Raleigh Office (919) 791-4200 Central Office (919) 733-5083 For more information about the programs of the Division of Water Quality's Stormwater Permitting Unit, see our home page at: http://h2o.enr.state.nc.us/su