March 29, 2016
Ronald D Autry
City of Dunn .•.
PO Box 1065
Dunn; NC 28335
SUBJECT: 3/16/2016 Compliance Evaluation Inspection
City of Dunn
Dunn WWTP
Permit•No: NC0043176
Harnett County
Dear Mr.'Autry:
PAT MCCRORY
Governor
DONALD R. VAN DER VAART
Secretary
S. JAY ZIMMERMAN
Director
Enclosed please find a copy of the Compliance Evaluation Inspection form from the inspection
conducted. on 3/16/2016. The Compliance Evaluation Inspection was conducted by Mark Brantley,
Environmental Program Consultant, of the Fayetteville Regional Office. The cooperation of Mrs. Donrie
Dukes, Grade IV ORC, was greatly appreciated. The facility was found to be in Compliance with permit
NC0043176. As a reminder, preservation_ of the Waters\'of the State can only be achieved through
consistent NPDES Permit compliance.
Comments
• Facility was clean and neat in appearance atthe time of the inspection.
• Maintenance records, ORC log, and operators log were up to date.
The aeration basin has a significant number of air leaks in the air distributionsystem.' Facility
staff stated that when an air leak was repaired a new leak would be created at the next weakest
spot in the air line. Having a significantamount of air leaks in the system reduces the amount
of air that is delivered to the, aeration basin which in turn reduces the efficiency of this
treatment unit. Reduced treatment efficiency can result in a NPDES permit limit violations such
as (but not limited to) Ammonia and BOD.: Please remember NPDES permit violations can result
in. Notices of Violation and/or Chill Penalty assessments with,fines up to $25,000 per day per
violation. Significant air Teaks can also increase power operating costs because the blower units
will have to work harder to supply the required air to the aeration basins. By having -the blower
units working harder this will increase wear and tear on these units which could cause major
repairs,to these units. Please consultthe town's engineering firm to determine the life -
expectancy of the air distribution system since these units were constructed in 1979 and have
had no major repairs or upgrades. The Division of Water Resources strongly encourages the
City of Dunn to begin studying ways to repair or replace the air distribution system. By studying
the system the City would be able to determine how to fund a replacement/repair project and
Fayetteville Regional, Office
225 Green Street, Suite 714, Fayetteville, North Carolina 28301-5095
Main Phone: 910-433-3300 1 Internet: http://www.ncdenr.gov
An Equal Opportunity\AtfirmativeAction Employer —Made iri part by Recycled Paper
Mr. Autry
Page 2
March 29, 2016
also select the best technology to replace the existing air distribution system. Please note
increased flow also increases the demand for air in the aeration basin. t
• The Division of Water Resources recognizes that the cityhas done a lot of work on the City's
Inflow and Infiltration (1/1) problem. However, a records review revealed flow violations for the
months of January, March, November 2015 and January 2106. These violations were caused by
wet weather periods which indicates more work needs to be done to correct the City's I/I
problem.
o The November 2015 eDMR was compared to the monthly laboratory bench sheets and no
transcription errors were found. /
Please refer to the enclosed inspection report for additional observations and comments. If you or your.
staff have any questions, please call me at.910-433-3327.
Sincerely,
Ai,nX
Mark Brantley
Environmental Program Consultant
Division of Water Resources
Water Quality Regional Operations Section
cc: Donrie Eldridge Dukes, ORC
Central Files
Fayetteville -Files .
United States Environmental Protection Agency
EPA Washington, D.C.20460
Water. Qompliance.lnsppction, Report., - .
Form Approved.
OMB No.2040-0057 .
Approval expires 8-31-98
- - Section A: National Data System Coding'(i.e.;'PCS) -
.
Transaction Code NPDES yr/mo/day • Inspection
1 IN I 2 I5 j 3 NC0043176 111 12 •, 16/03/16 17
Type
18
I. I III
Inspector Fac Type
19. Lsj• .2011
21I I I I I I I I I I I (I [ I I I I I I (I. I .III I. I. I(
I I
((I II .166
Inspection Work Days ( Facility Self -Monitoring Evaluation Rating B1 QA
67 I I • • 70L .. 71. IN. 1: 72 I N I
Reserved
�. 731 I 174 79
I. 1 1 1l 80
1-1
1
,Section B: FabilityData'
Name and.Location of Facility Inspected (For Industriall Users discharging to POTW; also include
POTW name and NPDES permit Number) . . . -
Dunn WWTP
Susan Tart Rd ..
Dunn NC 28335
Entry,Time/Date.
09:30AM 16/03J16 .'
Permit Effective Date
12/08/01
Exit Time/Date , -
•12:30PM ,: 16/03/16 .. •
. -.. .
Permit Expiration Date.
- ., ., .. . . .
•• -16/09/30 .
Name(s) of Onsite Representative(s)1Titles(s)/Phone and Fax Number(s)
///
ponrie Eldridge Dukes/ORC/910-892-8T62/ ;
Other Facility Data
•
Name, Address of Responsible OfficiaUTitle/Phone and Fax Number
Ronald D Autry,PO Box 1065 Dunn NC 28335//910-892-2633/-. ':. ' Contacted
--... No
• Section C'. Areas Evaluated'During Inspection (Check:only'those areas evaluated) .
Permit Flow Measurement . Operations & Maintenance Records/Reports ,
Self -Monitoring Program . Sludge Handling Disposal, ' -Facility Site Review . - Laboratory' .. •
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
'(See attachment summary) .. . .
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers . Date
Mark Brantley FRO WQ//910-433-3300 Ext.727/
"114 D3--)9-/1,.
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
�B�lirJ�da;S . enson RO WQ//910-433-3300 Ext.72E 3 .:2 _! ty
rl it3�t�c.Y .t4(: G��YD��
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page# 1
NPDES yr/mo/day Inspection Type
NC0043176 111 121 16/03/16 117 18 C I
(Cont.)
1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Comments
•Facility was clean and neat in appearance at the time of the inspection.
•Maintenance records, ORC log, and operators log were up to date.
•The aeration basin has a significant number of air Teaks in the air distribution system. Facility staff
stated that when an air leak was repaired a new leak would be created at the next weakest spot in the
air line. Having a significant amount of air leaks in the system reduces the amount of air that is
delivered to the aeration basin which in turn reduces the efficiency of this treatment unit. Reduced
treatment efficiency can result in a NPDES permit limit violations such as (but not limited to) Ammonia
.and BOD. Please remember NPDES permit violations can result in Notices of Violation and/or Civil
Penalty assessments with fines up to $25,000 per day per violation. Significant air leaks can also
increase power operating costs because the blower units will have to work harder to supply the
required air to the aeration basins. By having the blower units working harder this will increase wear
and tear on these units which could cause major repairs to these units. Please consult the town's
engineering firm to determine the life expectancy of the air distribution system since these units were
constructed in 1979 and have had no major repairs or upgrades. The Division of Water Resources
strongly encourages the City of Dunn to begin studying ways to repair or replace the air distribution
system. By studying the system the City would be able to determine how to fund a replacement/repair
project and also select the best technology to replace the existing air distribution system. Please note
increased flow also increases the demand for air in the aeration basin.
•The Division of Water Resources recognizes that the city has done a lot of work on the City's Inflow
and Infiltration (1/1) problem. However, a records review revealed flow violations for the months of
January, March, November 2015 and January 2106..These,violations were caused by wet weather
periods which indicates more work needs to be done to correct the City's I/1 problem.
•The November 2015 eDMR was compared to the monthly laboratory bench sheets and no
transcription errors were found.
Page# 2
Permit: NC0043176
• Inspection Date: 03/16/2016
Owner - Facility: Dunn W WTP
Inspection Type: Compliance Evaluation
Operations & Maintenance Yes No 'NANE
Is the plant generally clean with acceptable housekeeping? ❑ ❑ ❑
Does. the facility analyze process control parameters, for ex: MLSS, MCRT,. Settleable ▪ ❑ • El ❑
Solids, pH, DO, Sludge Judge, 'and other that are applicable?
Comment:
Permit
(If the present permit expires in 6 months or less). Has the permittee submitted a new
application?
Is the facility as described in the permit?
# Are there any special conditions for the permit?
Is access to the plant site restricted.to the general public?
Is the inspector granted access to all areas for inspection?
Comment:
Record Keeping
Are records kept and maintained as required by the permit?
Is all required information readily available, complete and current?
Are all records maintained for 3 years (lab. reg. required 5 years)?
Are analytical results consistent with data reported on DMRs?
.J
Is the chain -of -custody complete?
Dates, times and location of sampling
Name of-individual,performing:the sampling
Results of analysis -and calibration
Dates of analysis
Name of -person performing analyses
Transported COCs
Are DMRs complete: do they include all permit parameters?
Has the facility submitted its annual compliance report to users and DWQ?
(If the facility is 7 or > 5 MGD perinitted'-flow) Do they operate 24/7 with a certified operator
on each shift?
Is the ORC visitation log available and current?
Is the ORC certified at grade equal to or higher than the facility classification?
Is the backup operator certified at grade less or greater than the facility classification?
Is a copy of the current NPDES permit available on site?
Yes. -No .NA NE
-II El El
• ❑ ❑ ❑
D. ❑ U EL.
El
�.0❑ 0
Yes No NA NE
▪ ❑ ❑ ❑
▪ ❑ ❑ ❑
p El El
•
■ ❑ ❑ ❑
• ❑ ❑ ❑
—▪ ❑ ❑ El
El El III
10 ❑ ❑ ❑
• .b ❑ ❑
--o ❑ ❑
❑ ❑ ❑
Page# 3
Permit: NC0043176
Inspection Date: 03/16/2016
Owner -Facility: DunnWWfP
Inspection Type: Compliance Evaluation
Record Keeping
Facility has copy of previous year's Annual Report on file for review?
Comment:
Yes No NA NE
MI ❑ ❑ ❑
Flow Measurement - Effluent Yes No NA NE
# Is flow meter used for reporting? ® ❑ 0 0
Is flow meter calibrated annually? 1 0 ❑ 0
Is the flow meter operational? _ ® 0 0 ❑
(If units are separated) Does the chart recorder match the flow meter? ' ❑ ❑ 0 111
Comment:
Aerobic Digester Yes No NA NE
Is the capacity adequate? 11 0 ❑ ❑
Is the mixing adequate? 11 0 0 ❑
Is the site free of excessive foaming in the tank? • 0 ❑ 0
# Is the odor acceptable? 11 0 0 0
# Is tankage available for properly waste sludge? •❑ 0 0
Comment:
Solids Handling Equipment
Is the equipment operational?
Is the chemical feed equipment operational?
Is storage adequate?
Is the site free of high level of solids in filtrate from filter presses or vacuum filters?
Is the site free of sludge buildup on belts and/or rollers of filter press?
Is th'e site free of excessive moisture in belt filter press sludge cake?
The facility has an approved sludge management plan?
._Comment:,_
Pump Station.- Effluent
Is the pump wet well free of bypass lines or structures?
Are all pumps present?
Are all pumps operable?
Are float controls operable?
Yes No NA NE
El ❑ ❑ ❑
11 ❑ 0 ❑ ,
❑ ❑ ❑
❑ ❑ I ❑
❑ ❑11 ❑
❑ ❑ 11 ❑
MI ❑l ❑ ❑
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• .❑ ❑ ❑
▪ ❑ ❑ ❑
Page# 4
Permit: NC0043176
Inspection Date:, 03/16/2016
Owner -Facility: DunnWWfP
Inspection Type: Compliance Evaluation
Pump Station'- Effluent
Is SCADA telemetry available and operational?
Is audible and visual alarm available and operational?
Comment:
Pump Station - Influent
Is the pump wet well free of bypass lines or structures?
Is the wet well free of excessive: grease?
Are all.pumps present?
Are all pumps operable?
' Are float controls operable?
Is SCADA telemetry available end • operational?
Is audible and visualalarm available and operational?
Comment:
Bar Screens
Type of bar screen
a.Manual
b.Mechanical
Are the bars adequately screening debris?
Is the screen free of excessive debris?
Is disposal of screening in compliance?`
Is the.unit in -good condition?
Comment:
Grit Rernoval_
Type of grit removal
a.Manual
b.Mechanical =
Is thegrit free of excessive organic matter?
Is the grit free of excessive odor?
#is disposal of grit.in,compliance?
Comment:
.Yes No -NA r NE -"
-p ❑ ❑.,❑ :
Yes No NA NE
� . ❑ ❑ ❑,
▪ ❑ ❑ ❑
• ❑ ❑ ❑
❑ ❑ ❑
- Yes No, NA NE..
Yes''No'NA NE:'>::'
Page# 5
-
Inspection Date: 03/16/2016
Permit: NC0043176 Owner - Facility: Dunn WWTP
Inspection Type: Compliance Evaluation
Equalization Basins
Is the basin aerated? •„•
Is the basin free of bypass lines or structures to the natural 'environment?
Is the basin free of excessive grease?
Are all pumps present?
Are all pumps operable?
Are float controls operable?
Are audible and visual alarms operable?
# Is basin sie/volume adequate?
Comment:
Secondary Clarifier
Is the clarifier free of black and odorous wastewater?
' .
Is the site free of excessive buildup of solids in center well of circular clarifier?
Are weirs level?
Is the site free of weir blockage?
- Is the site free of evidence of short-circuiting?
Is scum removal adequate?
Is the site free of excessive floating sludge?
Is thedriveunit operational?
Is the return rate acceptable (low turbulence)?
Is the overflow clear:of excessive solids/pin floc?
Is the sludge blanket level acceptable? (Approximately % of the sidewall depth)
Comment:
Aeration;Basins
Mode of operation
Type of aeration system
• Is the basin free of dead spots?
Are SO-leap:aerators:end mixers operational?
Are diffusers operational?
Is the foarn,theproper color for the treatment process?
Dees the foam cover less than 25% of the basin's,surface?
Is the DO level acceptable?
Yes, No NA, NE
• th.o 0.;
▪ 0 0 0'
▪ El 1=1
IN 0 El 0
11 El 0 0
▪ 1=1 El 0
0 •1=1 0 •
0 0 El 11
Yes No NA. NE -
Ext. )?,kir,
Diffused ,
p .1=1
0 • 0
II 0 0 1=1
. • 1=1 Ell 0
1000
Page# 6
Permit: NC0043176
Inspection Date: 03/16/2016'
Owner - Pacility: Dunn VVI TP
Inspection Type: Compliance Evaluation
Aeration Basins
Is the DO level acceptable?(1.0 to 3.0 mg/I)
Comment:
r
De -chlorination
Type of system ?
Is the feed ratio proportional to chlorine amount (1 to 1)?
Is storage appropriate for cylinders?
# Is de -chlorination substance stored away from chlorine containers?
Comment:
Are the tablets the proper size and type?
. Are tablet de -chlorinators operational?
Number of tubes in use?
Comment:
Yes No NA -NE
� ❑ 0 0
Yes No NA NE
Liquid
• ❑ ❑ ❑
❑ ❑ • ❑
11000
❑ ❑ U ❑
Standby Power Yes No NA NE
Is automatically activated standby power available? • .: ❑ 0 -.❑
Is the generator tested by interrupting primary power source? 1, ❑ .❑ 0
Is the generator tested under Toad? - , ❑ ,0 : 0
Was generator.tested & operational during the inspection? .❑ ❑, ❑ •
Do the generator(s) have adequate capacity to operate the entire wastewater site? 1 0 0 0
Is there an emergency agreement with a fuel vendor for.extended run on.back-up power? ❑ 0 ❑
Is the generator fuel level monitored? • 0 Cl
Comment:
Pumps-RAS WAS
Are pumps it place?
—Are pumps•operational?
Are there adequate spare parts.and supplies on site?
Comment:
Laboratory
Are field parameters performed by certified personnel or laboratory?
-Are all other parameters(excluding field parameters) performed by a certified lab?
Yes No NA =NE'
siobth
❑ ❑-
Yes" No"•NA NE
II ❑ ❑ ❑
Page#
Permit: NC0043176 Owner - Facility: Dunn wwTP
Inspection Date: 03/16/2016
Inspection Type: Compliance Evaluation
Laboratory
# Is the facility using a contract,Iab?
# Is proper temperature set for sample storage (kept at Tess than or equal to 6.0 degrees
Celsius)?
Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees?
Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees?
Comment:
Disinfection -Liquid
Is there adequate reserve supply of disinfectant?
(Sodium Hypochlorite) Is pump feed system operational?
Is bulk storage tank containment area adequate? (free of leaks/open drains)
Is the level of chlorine residual acceptable?
Is the contact chamber free of growth, or sludge buildup?
Is there chlorine residual prior to de -chlorination?
Comment:
Influent Sampling -
# Is composite sampling flow proportional?
Is sample collected above side streams?
Is proper volume collected?
Is the tubing clean?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
Celsius)?
Is sampling performed according to the permit?
Comment:
Effluent Sampling
Is composite sampling flow proportional?
Is sample collected below all treatment units?
Is proper volume collected?
Is the tubing clean?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type
representative)?
Yes No NA NE
11 ❑ ❑ ❑
▪ Cl ❑ ❑
▪ ❑ ❑ ❑
❑ ❑ II ❑
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
® ❑ ❑ ❑
II ❑ ❑ ❑
❑ ❑ ❑ MI
M.❑ ❑ ❑
Yes No NA NE
❑ ❑ .11 ❑
II ❑ ❑ ❑
❑ ❑ ❑
•❑ ❑ ❑
❑ ❑ ❑
1 ❑ ❑ ❑
Yes No NA NE
— ▪ ❑L❑ -❑ -- ___
• El ❑ ❑
® ❑ ❑ ❑
II ❑ ❑ ❑
▪ ❑ ❑ ❑
1 ❑ ❑ ❑
Page# 8
Permit: NC0043176
Owner - FaCility: Dunn WVVTP
Inspection Date': 03/16/2016 Inspection type: Compliance Evaluation
Effluent Sampling
Comment:
Upstream / Downstream Sampling
Is the facility sampling performed as required by the permit (frequency, sampling type, and
sampling location)?
Comment: Facility is a member of the Middle Cape Fear River Basin Association.
Yes No NA NE
Yes No NA NE
El El II D1
Page# 9