Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NCG551638_Application Submittal_20140924
BCSC BATEMAN CML SURVEY COMPANY Bateman Civil Survey Company; PC 200 North Main Street Holly Springs, NC 27540 September 24, 2014 Mr. Charles Weaver NCDENR — Division of Water Quality 512 N. Salisbury Street Raleigh, NC 27604 RE: NPDES Notice of Intent for 7846 Amesbury Road, Fayetteville, NC 28311 BCS Project #: 140370 Dear Mr. Weaver: DENR-FRO OCT 0 2 "2014 I�3 Phone: (919) 577-1080 Fax: (919) 577-1081 info@batemancivilsurvey.com l o ; R b 4 ti : 8t,1;,.A4 WLn3vl., Frl"' ` IN 1 l)eyeK De HAY OI NIPOF.:S RECEIVED/DENR/DWR SEP 2 4- 2014 Water Quality Permitting Section On August 2nd 2014, we submitted a Notice of Intent application and application fee for 7846 Amesbury Road. We are resubmitting the application with the full design and attachments. Attached please find three copies of Notice of Intent application planned for a three bedroom single family home to be located at 7846 Amesbury road in Cumberland County, N.C. The package includes a completed Notice of Intent application for coverage under NCG550000 for single-family domestic units, the full wastewater design with accompanying documentation. The site consists of a 0.56 acre lot and does not meet the setbacks required for a spray or surface drip system. The nearest municipal wastewater collection system is the City of Fayetteville system. The closest connection is approximately 22,226 feet from the residence. The cost to connect to the system is estimated to be a minimum of $1,600,000. This estimate uses a cost to construct a gravity main for this distance of $60/foot and a cost for a pump station of $300,000 (minimum). If you have any questions or comments regarding this application please contact us by phone at (919) 577-1080. Sincerely, BATEMAN CIVIL SURVEY COMPANY, PC fradre64--- Matt Burdette Sr. Environmental Specialist 7846 Amesbury Road BCS Project #: 140370 09/24/14 Page 2 of 2 BATEMAN CIVIL SURVEY COMPANY, PC &A:4 Brian J. Kraynak P.E. ® gage®song®® % Jo-42- 0 4. . SEAL z L Tit It. 033402 , %Fe A®6®eCeel q-0(7-0.167 RECEIVEDIDENRIDWR SEP 2'4 2014 WaterQuality. Permitting Section Fayetteville Regional Office - SWP Staff Report Form \ To: Derek Denard , Verify permit Information against BIMs Information. Note any corrections required. \ Permit Number Permittee Roundpoint 4sset Management, Inc Facility Name 7846 Amesbury goad Facility County Cumberland Regional Office Fayetteville RO Contact person Mark Brantley Date 11/21/2014 Facility Location 17846 Amesbury Road, Fayetteville, NC 28311 Status of existing treatment: 'Failing drain field for existing septic tank system. Discharge Point(s): Latitude Longitude Waterbodv: Receiving Stream UT to Little River Stream Classification Class C River Basin Cape Fear River Sub -basin Stream Index 18-23-(24) Maximum flow [360 GPD Last inspection This is a proposed treatment process for this location. Review Special Conditions Alternatives: none Spray irrigation Regional sewer connection Subsurface Other disposal options Recommendation: Deny Ettiuent tram proposed treatment system virus aramfrom the ba k-cdrner of the property through some rip rap before entering into a "dry ditch of a UT to the Little River" under normal conditions. Discharging treated wastewater to this "dry ditch" is not the best scenario for the Waters of the State or the environment. The "dry receiving ditch" also borders several properties along its path to the Little River. Also there is a potential public health concern with this system discharging in a residential area. The FRO is concerned about kids playing in the discharge area and coming in contact with effluent. If permitted, we would highly recommend language in the permit that a maintenance agreement be set up with a reputable company. Supervisor approval: &t4WO Ai %4'kt7D • Fayetteville Regional Office - SWP Staff Report Form To: Derek Denard Verify permit Information against BIMs Information. Note any corrections required. Number Permittee Roundpoint Asset Management, Inc Facility Name Facility Name 7846 Amesbury Road (-610Permit 7846 Amesbury Road (—(/L Facility County Cumberland Regional Office Fayetteville RO Contact person Mark Brantley Date 11 /21 /2014 Facility Location 7846 Amesbury Road, Fayetteville, NC 28311 Status of existing treatment: Failing drain field for existing septic tank system. Discharge Point(s): Latitude Longitude Waterbody: ±I ; o t< uoL Receiving Stream UT to Little River ; y �� Gu Stream Classification Class C WmO r' Inc c co:, River Basin Cape Fear River go 00 C 0 ur,11 Sub -basin I rnct K file , r Stream Index 18-23-(24) I d i 0'1' cc`%5 .(- Maximum flow 360 GPD Last inspection This is a proposed treatment process for this location. Review Special Conditions Alternatives: none Spray irrigation Regional sewer connection , Subsurface o Other disposal options 4ce we s07.ti y P y p '� °� not ° eewl'', ' ° `,'' ' cite w1 Loge,,,n w4eh ../ does PL° f w°tu, Recommendation: Deny ray'", t° Z? CCtP�✓! `" / din/ gt-` word f , s, Effluent from proposed property through River" under normal is not the best 011ut treatment system will drain from the back corner of the some rip rap before entering into a "dry ditch 'of a UT to the Little conditions, Discharging treated wastewater to this "dry ditch', scenario for the Waters of the State. or the environmentdue-to-the( -f re-m �nT,�.r to t4reatm�T en is. The "dry 'ctem�• � �II o� borders several properties along its path to the Little River. •u61ic`health concern with this -system discharging in a residential receiving ditc Also there is area. • h-the-effluent-and-become-sick. discharge area cerned-that + se _the-area-may-come-in-cont�cc,t E-speeially�concerned about kids playing in the and in contact with effluent. (coming .i berm Zf 1-h47- CU mco•n knene,� a'c ill- be sat- �( }2 �; a re_ pa %J)/e_ Co ri 13' '► ( `Choi, tr-i- )f ' Supervisor approval: d1- sof(' LAC c wz co, no COI- of filese S e S y 4-e4 -s v� buse/ ens 4e5e Petzsons 5 'ice ey {v-'is IVA NCDENR Division of Water Resources National Pollutant Discharge Elimination System (NPDES) Application for Coverage Under General Permit NCG550000 Single Family Residences andlor facilities discharging < 1000 gallons per day of domestic wastewater NOTICE OF INTENT [Required by 15A NCAC '02H A 127(d)J: [term definition see 15A NCAC 02H :0103(19)] (Press TAB to navigate form) FOR AGENCY USE ONLY Date Received Year Month Day aoI4 og a9 . Cerhficaie of Coverage. , N C G 5 511 (Q 3 Fj Check # __,�Amount. II • AssignedTo:17e,(e,1L, 4,rNatf'ei. 1. Regional Office contact (Please note: This application will be returned if you have not met with a representative from the appropriate regional office.): Please list the NCDENR Regional Office representative(s) with whom you have met: Name(s): Belinda. Henson Phone Call Date: 8/14/2014 2.. Mailing address of owner/operator:. (address to'which all correspondence should b eAl, ENEDIDEN Owner Name Roundpoint Asset Management, Inc Attn: Lee Herrera �KC� Street Address PO Box 87203 City Fayetteville State NC Zip28304 - Telephone # (H) 910-829-9405 Telephone # (W) Cell/Mbbile # 91047642,68 Email Lee@assetne.com 3. Location of facility producing discharge: (Iffacility is not yet constructed, give:str•eet address or lot #) Street Address 7846'Atriesbury Road ��� City Fayetteville State NC Zip 28311 - lVE� County Cumberland Telephone # Cell/Mobile # SEP - 5 2014 4. Physical location information: DENR—FAYErT EVILLEREGIONAL OFFICE Please provide a narrative description of how to get to, the facility (use street names, state road numbers, and distance and direction, from a roadway .intersection). From downtown Fayetteville take Ramsey St. north to Elliot Bridge rd then turn right on to Whispering pines rd then turn right on to Ainesbury rd. stop at the forth house on the left 7846 Amesbury rd. 5. This NPDES permit application applies." to which of the following : ❑ New [term definition see I SA NCAC 02H .0103(16)] or Proposed (system not constructed) AUG2.92°I4 WR VJatet �,t�anty Permitting Section n [2 Existing [term definition see 15A NCAC 02H .0103(11)1; if previously permitted by local or county heajt'h department, -please -provide the .permit -number see attached denial letter ,` and issue date Click here to enter a date. ra �. ❑ Modification; please describe the nature of the modification: (• � 4a . . j. f.r .1 to 0 .,� v' Page 1 of 4 `'Revised 9/1113; NCG550000 New Application 6. Description of Discharge: [Required by 15A NCAC 02H .0105(c)(1)] a). Amount of wastewater to be discharged: Number of bedrooms 3,x 12Q gallons per bedroom 360 360 gallons per -day to be permitted b), Type of facility producing waste (please check ;Primary residence • ❑ Vacation/second home ❑. Other: 7. Please. check the 'components that comprise the wastewater treatment system: [Required by 15A.NCAC 02H .O.105(c)(3)] Septic tank' ❑ Dosing tank ❑ Primary sand filter ❑ Secondary sand filter ® Recirculating Sand filter(s) ❑ Chlorination- ,❑ Dechlorination ® Other form of disinfection: UV ❑ Post Aeration (sped type) 8; For new or proposed systems only - Please address the feasibility: of alternatives to discharging for the following options in the cover letter for this app lication: [Evaluation,required by G.S. § 143-215.1(6)(5)(a) and 1SA NCAC 02H .0105(c)(2)1 a) Connection to a Regional or Municipal Sewer Collection System. b) Letter -from local or county health department describing the suitability or non -suitability of the site for all types of wastewater ground adsorption and innovative non -discharge systems. Document the repair potential of the failed. system. c) Land Application such as spray irrigation or drip irrigation. 9. .Receiving waters: [Required by 15A NCAC 02H .0105(c0(1)J a) What is the name of the body, or bodies of water (creek, stream, river, lake,etc.) that the facility wastewater discharges end up in? UT to Little River b) Stream Classification (if known): 10. The application must include the following or it will be returned, as allowed by 15A NCAC 02H .0107(b): a) For Certificates of Coverage: ® An original letter and two (1) copy requesting coverage under NCG550000. ® A signed and completed original and one copy of this Notice of Intent Application. ® A check or money order for the permit fee of $60.00 [per G.S. & 143-215.3(a)(lb)] made payable to NCDENR. ❑ Invoice:showing that the septic tank has been pumped and serviced within the last 12 months (only when existing service tank will be used). Page 2 of 4 Revise 9/1 /13 NCG550000 New Application New or proposedfacilities .must also include: ❑ Letter from, the county health department evaluating the proposed site for all types of ground absorption and innovative non -discharge systems. Document the repair potential of the failed system. ❑ Evaluation of connection to a:regional sewer system (approximate distance &cost.to connect). ❑ Provide a 7Q10 flow estimateat the proposed wastewater discharge point from the US Geological Survey (919- 571-4000) b) For an Authorization to Construct (ATC) only: (Note: There is no :fee for an ATC) ❑ A letter requesting an ATC ❑ Three sets of plans and specifications (required by 15A NCAC 024 .0138) of proposed treatment system (see Permit Application Checklist and.Design Criteria for Single Family Discharge) ❑ Invoice showing that. the septic tank has been pumped and serviced within the last 12 months (only when existing septic tank will be used): Additional Application Requirements: a). If this application is being submitted by a consulting engineer (or engineering firm), include documentation from the applicant showing that the engineer (or firni) submitting the application has been designated an authorized Representative of the applicant, per 15A.NCAC 02H .0138(b)(i). b) If this application is being submitted .bya consulting engineer (or engineering firm), final plans for the treatment system must be signed arid` sealed by a North Carolina_ registered Professional Engineer and stamped —"Final Design - Not released for construction;" per 15A NCAC 02H .0139. c) If this application is being submitted by a consulting engineer (or engineering firm),. final specifications for all major treatment components must be signed and sealed by a North Carolina registered Professional Engineer and shall include a narrative description of the treatment system to be constructed; per 15ANCAC 02H .0139.. • Page 3 of 4 Revised 9/1/13 ;NCG5500.00';New Application CERTIFICATION; 1 certify.that 1 am familiar with Ale information contained in this application and that to thebest of my knowledge and belief such: information is true, complete, and accurate. Printed Name of Person Signing: ' Title: 2 Z,e:G ..` C t,ter4-::...: /4'r (Please review 15A NCAC 02H .0106(e) for authorized signing officials) :(S►gnat' e of , .p WOO' . North Carolina' Generall:Statute S 143-215:61i provides; that: Any person who knowingly makes, any false statement representation; gr certification: in any.appl cation, record, report;, plan, or other document filed or required to'oe maintained Under this Article, or a• rule. implementing this Article;; or who knowingly tnoKep a false 'statement of a material fact in a.rulemaking proceeding .or contested•case:under'this Article:- orWho'falsifies 10rOort with; or'..: knowingly renders inaccurate:any recording Or monitoring device, or method required to be operated or maintained under this Article . • • or rules of the Commissionimplementing this Article;, shall be guilty' of a Class 2 misdemeanor which may include,. a fine -riot ,to • • • exceed ten, thousand dollars ($10;000) • 18 U.S.C. Section .9001-:provides a punishment by a fine..or imprisonment not more than 5. years, :orboth;• for a similar offense. Click here to enter a (Date: Signed) e: Application "nust,be accompanied'by a' check.or. nioney order.. for S60;00.[perG.S._ § :14=3-215.3(a)(lb)1 made' payable to: NCDENR •••:•• ......... . Mail this application and one copy of the entire package (with check) .to: NC DENR %.D WR./ Water Quality Permitting Section 1.617 Mail Service Center Raleigh, North Carolina 27699-1617 Attn Charles Weaver: Note: The submission of this document does not guarantee the issuance of an NPDES permit Revised 9/1/13 SCANNED OUNTY':of. �:UMB E. Newton Smith Public Health Center October 6, 2005 To Whom It May Concern::: ocated at 7846 Amesbury Road has a.fai ing on' site, waste` water The property:l ..... on ties: ro erty on.6�13=�3.by ��.; condiicted _ pr p n - aite:and soil evaluation.was .. . ,. ti=� ;� roe ��has•a;.non= s sterii. 'A .. ef=., _..,.A4 r ` , rty.. .._ Y e de ue4 T s p ha' soil scienris .10 / Eeu; t 1 r AjmaTHes am; ... _ ,. .��...� �- avail�lile-space.�. stem,due to soil .wetness ands rrel�I'able:on�site�was'te�wateir:.sy If I cari be of further assistance please eall: me„at (910) 433 3685;. 8;00 1:00:- pm ., Monda Friday:. 1:30-or:4:30 — :. p.: .Very billy yours,. • 6529 Fo untainhead:Lane' Fayeueville, North Carolina 28301 • Phone:(910) 433-3600 Fax (910) 433=3 227 BATEMAN CIVIL SURVEY COMPANY Bateman Civil Survey Company, PC 200 North Main Street Holly Springs, NC 27540 August 27, 2014 Mr. Charles Weaver NCDENR — Division of Water Quality 512 N. Salisbury Street Raleigh, NC 27604 RE: NPDES Notice of Intent for 7846 Amesbury Road, Fayetteville, NC 28311 BCS Project #: 140370 Dear Mr. Weaver: Phone: (919) 577-1080 Fax: (919) 577-1081 info@batemancivilsurvey.com RECEIVED/DENR/DWR AUG 29 2014 vvattn Uuality Permitting Section Attached please find three copies of Notice of Intent application planned for a three bedroom single family home to be located at 7846 Amesbury road in Cumberland County, N.C..The package includes a completed Notice of Intent application for coverage under NCG550000 for single-family domestic units and an agent authorization letter. Bateman Civil Survey has been retained to design a repair system consisting of an septic tank, and an Advantex Pretreatment system, with controls and splitter valve, a UV unit providing secondary treatment and disinfection prior to final disposal, and final disposal is provided by gravity flow from the UV unit to a rip -rap disposal pad. Details of the treatment system will be submitted in the next two weeks. The site consists of a 0.56 acre lot and does not meet the setbacks required for a spray or surface drip system. The nearest municipal wastewater collection system is the City of Fayetteville system. The closest connection is approximately 22,226 feet from the residence. The cost to connect to the system is estimated to be a minimum of $1,600,000. This estimate uses a cost to construct a gravity main for this distance of $60/foot an''d a cost for a pump station of $300,000 (minimum). 7846 Amesbury Road BCS Project #: 140370 08/27/14 Page 2 of 2 If you have any questions or comments regarding this application please contact us by phone at (919) 577-1080. Sincerely, BATEMAN CIVIL SURVEY COMPANY, PC Matt Burdette Sr. Environmental Specialist BATEMAN CIVIL SURVEY COMPANY, PC Brian J. Kra�ru� P.E. H CA/0 O°QFeS$�' ®` ten`®® Q¢ a „® S� ; L ; 032 p a000 Ad. KRio 4-0:1866,311003 gr gy_ ao/L NPDES Septic System Design for 7846 Amesbury Road — Fayetteville, North Carolina Designed by: Matt Burdette Bateman Civil Survey Company, PC 200 North Main Street, North Carolina 27540 BCSC Project #: 140370 RECEIVED/DENR/DWR SEP 2 4 2014 Water Quality Permitting Section September 2014 7846 Amesbury Road — Fayetteville, North Carolina Table of Contents Notice of Intent Application 1 Agent Authorization Form 5 Cumberland County Denial Letters 6 System Specifications 11 Control Panel Specifications - 16 Effluent Pump Specifications - 19 Biotube Pump Vault Specifications 23 Effluent Filter Specifications 25 Chlorinator / De -chlorination Specifications 27 Attachments Site Plan / Location Map Pretreatment Disinfection and Disposal Details AdvanTex Installation Manual Sheet 1 Sheet 2 NCDENR Division of Water Resources National Pollutant Discharge Elimination System (NPDES) Application for Coverage Under General Permit NCG550000 Single Fancily Residences and'or facilities discharging < 1000 gallons per day of domestic wastewater NOTICE OF INTENT [Required by 15A NCAC 02H .0127(d)]; [term definition see 15A NCAC 02H .0103(19)] (Press TAB to navigate form) FOR AGENCY USE ONLY Date Received Year Month Day Certificate of Coverage N C G 5 5 Check r I Amount Assigned To: 1. RegionaI Office contact (Please note: This application will be returned if you have not met with a representative from the appropriate regional office.): Please list the NCDENR Regional Office representative(s) with whom you have met: Name(s): Belinda Henson Phone Call Date: 8/14/2014 2. Mailing address of owner/operator: (address to which all correspondence should be mailed) Owner Name Street Address City Telephone # (H) Cell/Mobile t Roundpoint Asset Management, Inc Attn: Lee Herrera PO Box 87203 Fayetteville State NC 910-829-9405 Telephone # (W) 9104764268 Email Zip28304 - Lee@assetnc.com 3. Location of facility producing discharge: (Iffacility is not yet constructed, give street address or lot #) Street Address City County Telephone 4 7846 Amesbury Road Fayetteville Cumberland State NC Zip 28311 - Cell/Mobile 4 4. Physical location information: Please provide a narrative description of how to get to the facility (use street names, state road numbers, and distance and direction from a roadway intersection). From downtown Fayetteville take Ramsey St. north to Elliot Bridge rd then turn right on to Whispering pines rd then turn right on to Amesbury rd. stop at the forth house on the left 7846 Amesbury rd. 5. This NPDES permit application applies to which of the following ❑ New [term definition see 15A NCAC 02H .0103(I6)] or Proposed (system not constructed) ® Existing [tertn definition see 15A NCAC 02H .0103(11)]; If previously permitted by local or county health department, please provide the permit number see attached denial letter and issue date Click here to enter a date. ❑ Modification; please describe the nature of the modification: Page 1 of 4 Revised 9/1/13 NCG550000 New Application 6. Description of Discharge: [Required by ISA NCAC 02H .0105(c)(l)] a) Amount of wastewater to be discharged: Number of bedrooms 3 x 120 gallons per bedroom = 360 360 gallons per day to be permitted b) Type of facility producing waste (please check one): N Primary residence ❑ Vacation/second home ❑ Other: 7. Please check the components that comprise the wastewater treatment system: [Required by 15A NCAC 021-1 .0105(cl(3)] Septic tank ❑ Dosing tank ❑ Primary sand filter ❑ Secondary sand filter ❑ Chlorination ❑ Dechlorination ❑ Post Aeration (specify type) 8. For new or proposed systems only - Please address the feasibility of alternatives to discharging for the following options in the cover letter for this application: [Evaluation required by G.S. S 143-215.1(b)(5)(a) and ISA NCAC 021-I .0105(c)(2)] a) Connection to a Regional or Municipal Sewer Collection System. b) Letter from local or county health department describing the suitability or non -suitability of the site for all types of wastewater ground adsorption and innovative non -discharge systems. Document the repair potential of the failed system. N Recirculating sand filter(s) N Other form of disinfection: UV c) Land Application such as spray irrigation or drip irrigation. 9. Receiving waters: [Required by 15A NCAC 02H .0105(c)(1)] a) What is the name of the body or bodies of water (creek, stream, river, lake, etc.) that the facility wastewater discharges end up in? UT to Little River b) Stream Classification (If known): 10. The application must include the following or it will be returned, as allowed by 15A NCAC 02H .0107(b): a) For Certificates of Coverae.e: N An original letter and two (1) copy requesting coverage under NCG550000. • A signed and completed original and one copy of this Notice of Intent Application. N A check or money order for the permit fee of S60.00 [per G.S. I43-215.3(al(lb)] made payable to NCDENR. ❑ Invoice showing that the septic tank has been pumped and serviced within the last 12 months (only when existing service tank will be used). Page 2 of 4 Revised 9/1/13 NCG550000 New Application New or proposed facilities must also include: ❑ Letter from the county health department evaluating the proposed site for all types of ground absorption and innovative non -discharge systems. Document the repair potential of the failed system. ❑ Evaluation of connection to a regional sewer system (approximate distance & cost to connect). ❑ Provide a 7Q 10 flow estimate at the proposed wastewater discharge point from the US Geological Survey (919- 571-4000) b) For an Authorization to Construct (ATC) only: (Note: There is no fee for an ATC) ❑ A letter requesting an ATC ❑ Three sets of plans and specifications (required by I5A NCAC 02H .0138) of proposed treatment system (see Permit Application Checklist and Design Criteria for Single Family Discharge) ❑ Invoice showing that the septic tank has been pumped and serviced within the last 12 months (only when existing septic tank will be used). Additional Application Requirements: a) If this application is being submitted by a consulting engineer (or engineering firm), include documentation from the applicant showing that the engineer (or firm) submitting the application has been designated an authorized Representative of the applicant, per 15A NCAC 02H .0138(b)(1). b) if this application is being submitted by a consulting engineer (or engineering firm), final plans for the treatment system must be signed and sealed by a North Carolina registered Professional Engineer and stamped - "Final Design - Not released for construction;" per 15A NCAC 02H .0139. c) If this application is being submitted by a consulting engineer (or engineering firm), final specifications for all major treatment components must be signed and sealed by a North Carolina registered Professional Engineer and shall include a narrative description of the treatment system to be constructed; per 15A NCAC 02H .0139. Page 3 of 4 Revised 9/1/13 INUU55000U 1New Application CERTIFICATION 1 certify that I am familiar with the information contained in this application and that to the best of my knowledge and belief such information is true, complete, and accurate. Printed Name of Person Signing: Title: 2 /°•4 t (Please review 15A NCAC 02H .0106(e) for authorized signing officials) Click here to enter a Elate. (S• igrratrre of rp want) (Date Signed) North Carolina General Statute S. 143-215.6B provides that: Any person who knowingly makes any false statement representation, or certification in any application, record, report, plan, or other document filed or required to be maintained under this Article or a rule implementing this Article; or who knowingly makes a false statement of a material fact in a rulemaking proceeding or contested case under this Article; or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under this Article or rules of the Commission implementing this Article, shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed ten thousand dollars ($10,000). 18 U.S.C. Section 1001 provides a punishment by a fine or imprisonment not more than 5 years, or both, for a similar offense. Application must be accompanied by a check or monev order for S60.00 fper G.S. § 143-215.3(a)(1 b)1 made payable to: NCDENR • • ♦ ♦ ♦ Mail this application and one copy of the entire package (with check) to: NC DENR / DWR / Water Quality Permitting Section 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Attn: Charles Weaver Note: The submission of this document does not guarantee the issuance of an NPDES permit Page 4 of 4 Revised 9/1/13 BATEMAN CiV{L SURVEY:COMPANY Bateman Civil Survey Company, PC 200 North Main Street Holly Springs, NC 27540 AGENT AUTHORIZATION FORM NPDES Permits Unit Division of Water Resources 512 N. Salisbury Street Raleigh, North Carolina 27604 To Whom It May Concern: Phone: (919) 577-1080 Fax: (919) 577-1081 info@batemancivilsurvey.com By signing below, the current property owner gives representatives of Bateman Civil Survey Company permission to act as their authorized agent for the purpose of obtaining a single family discharge permit under the general permit NCG550000. Project Name: 7846 Amesbury Road BCSC Project #: 140370 Current Property Owner or Easement Holder: Name: Lee Herrera Roundpoint Asset Management Inc. (include contact person if a corporation, partnership, or government) Mailing Address: PO Box 87203 Fayetteville, North Carolina 28304 Telephone: 910-476-4268 Fax: Signal Ze-e , yede4e,i Print Name (include title, if appropriate) Date SCANNED COUNTY of CUMBERLAND E. Newton Smith Public Health Center October 6, 2005 To Whom It May Concern: ing on The property located at 7846 Amesburyct� on this propoad has a lerty on 6 t13 03 by Mr. e waste water system. A site and soil evaluation was con ro as a: non ' =re' y� rtT�ere air .quest,was"denieci�T�iis:p��P��?;Y=r Ajmal Heshaam, soil scientist. 4;r;. ;;,- p.�.,,;_ ;;repairable:on site; Taste Water systemnd avazla 1e space, If I can be of further assistance please call me at (910) 433-3685, 8:00 — 9:00 am, 1:00 — 1:30 pm, or 4:30 — 5:00 pm, Monday — Friday. Very truly yours, DS/bac Danny Soles • Environmental Health Supervisor 227 Fountainhead Lane • Fayetteville, North Carolina 28301 Phone (910) 433-3600 Fax (910) 433-3659 CUMBERLOD COUNTY HEALTH DEPARTMENT ENVIRONMENTAL HEALTH DIVISION 227 FountainheEld'Lane Fayetteville, NC 28301 Phone (919) 43373660 1 1- SCANNED , n (SEPTIC TANK) IMPROVEMENTS PERMIT AND:CERTIFICATE OF COMPLETION PERMIT VALID FOR 60 MONTHS FROMATE OF ISSUANCE, .OWNER /OCCUPANT ADDRESS 7846 AMESBURY RD. ACCOUNT NUMBER: REMARKS - LOCATION VISION -NAM#-'ELLERSLIE. FAYETTEVILLE 25564- ,• • ,•, 7846 AMESBURY RD MATEY, MARTIN- OR PAT \ NC 28301 -90USE.141 :MOBILE HOME ( 1 BUSINESS [ ] OTHER I ?..16.FibIltat*S/F1401P7 3 • $:oi17k OAP ' Site dlkation, - ' REPAIR PERMIT :Size of :''SelAj.c, Tank 0 'GalNitrification . Linep' .00 :sq. No. o'lineth I 2/50 X 3' - :W.eter Sqp:plyF instalqed Ye. Approved Yes No . X No SEWAGE..=SYSTEM,---- , A14, FNR-TpA)v-IAGE SYSTEM-44JST 'BE- AT, LEAST TratiTi .6.(21LE !MA RAFJ 0.T- a /2 WIVIA.Y(iiTTP14060aWi' THE 0wNpRC-7-4pqR-013 TO .CONE'OM ,t04 )T AND .BOARD.,,OF " HALT:REd014titON*; • tisTA4g -CAUEil,A1A:RRYL / - - pEt...arTdAtE OF cOmPtETVIali rsuant to krticla 11 of C4apter,-1-31:1 ,zot` ti • Coll*ItIl a:flit, dad D. ipos?.1Sit.4:4:.ROles- zhrlifi-e; 1 PERMIT NO DATE: 01/30/1i *-13 2 INSP.START DT: 01/30/5 TNsp • COUP. DT: brt.a574 THIS G. S,•TI-1RJS-'. -PEP , 6R11..11c,E, WAGE }( • )5. , )c.:44)‹ • 5-d -7tattiitrW-1 ofb P&C.L.7,9_7m4 • • • , • • • • ?cc'A5?1c,- . . and: 1900deulabd Couiftl-Aoai. , • . • *PI*- • 227 Fountainhead Lane Fayetteville NC 28301- (910) 433-3660 -,•. • • — • - sc_NNED03-3W-a Applit stion Date: 3/16/200e Reason(s) for Appliication': REPAIR -EXISTING SYSTEM Pin Number: 0543-07-3398 Site Address: 7846 AMESBURY ROAD Fayetteville NC 28301 Subdivision Lot: Phase: Section: ❑ vacant [;) Occupied APPLICANT I)tiFURMATIOU: Name: EDINA AMUNDSEN Applicant Status: Corrtrador / Builder Phone: 9102612102 Mt. Phone: Address: 3811 SYCAMORE DAIRY ROAD Fayetteviie NC 28303 Type of Wetl: Drilled 0 Bedroom :.3 Year Howse Built 1986 Type of Estabkshment: Residential Square Forage: 16Cp0 Date Property Origkwdy Deeded Recorded: D APPROVED 0 DENIED [j Plat J Property Approved Con/Malay by Planning Department 0 Property Zoned Zoning Permit No.: 0 «a CLEARLY STAXE AU. CORNBRS AND UNES Of THE PROPERTY' STAKE AIL CORNERS OF Alt PROPOSED STRUCTURES. SURVEY PLAT OR SITE PLAN MUST De ATTACHED TO THIS APPLICATION@ ** alto* (0) If a Local Health Department repeated pp�ttL, then Depsrtttxent o rO ment7i Health Naomi Rewu c may wthhord nitric hearth fund n that loot health dfalls to issue or deny Imonwement termite for conventional septic tank Wane within Oar( epartmentdays of �v' gat eted aleo means, for sebdivsaa,o, lots approved by the local planning auttioribt and recorded with the County Register of Drams, a copy of the recorded subdivision plat flat Is drawn to Kale., I berth', make application to the Cumbedand County Meath Department for a site evvaivadon for the on-dte sewage disposal system for the above-K.-embed property. 1 agree that the contents of this application are true and represent the maximum facilities to be placed on the property. I understand if the site is and altered, or the irtterixled use changes, the permit raml become invalid. I understand that as applicant, mberland County Health corttiu� theirslbla for ur iderttify�tConail�lur�ders�tarx! that i PertY Ones and ndbmake the site accessiblethe foreat tthD pason�offmyy ply contains wetlands designated by the Army Corp of Engineers, and if the site Is am responsive for notifying , Health Department sublet to approved by othe' — Application Number: 2006-399 THIS IS NOT A PERMIT PLEASE NOTE1 If the Information in the appecanon for an improvement permit is falsified, ctwnge d or the site ;s alters, then the improvement Permit and • Authorization to Construct shall become invalid. Copy of Zoning Permit or Zoning Status Form from County Zoning Office MUST BE SUBMITTED with Application For Sod Evattaiioris. • A plat drawn by a Regratered Lard Surveyor (RLS) to a scale of 1 Inch e,;x:ak no more than 60 feet Is valid with expiration. Authortiaton for Wastewater 5ys,'em CorstrUCiton (ATC) Is good for only nve (5) years, at which time It must be renewed. Applicant Signature: Received By: hnitial) 1 V Er A Site Plan (drawing) Is valid for five (5) years. A new application must be flied for the expired Improvement permit Authorhatlon forWastrrater Systriu Construction (ATC) is good For only five (5) years. Fees. S25.00 FIELD WORK RESULTS IBAED ON ATTACHED PLAT/SITE PLAN: AREA: -�-- LIAR: Site Classification. Repair; Design Fiary gpd Soil Type: Wastewater System: Nitrification Fiefs: Septic Tank: gallons Pump Tank: Type Specify Number of Lines: Length of Each Line: '-- Width of East Line 3r ench CCrrd14rr, ,fib r (s v,t+.Su; -7-,:g-Al Tex, A��7t 'Lit- st 'S gre. if.✓«, pt- ,rg_-; Ls - Soil/Site Evaluation By: gallons R-7 CUMBEL AND COUNTY HEALTH DEPARTmENT DIVIsION OF ENVIRONMENTAL ON -SITE WASTEWATER SECTION SOIL/SITE EVALUATION for ON -SITE WASTEWATER SYSTEMS risePt „Q.111.,N.ER-, im Arn-G61-10 ADDRESS; Ilse PROPOSED FACILITY: PR LOCATION OF SITE -2 eLi Le, WATER SUPPLY: A, 0 Private Orgi Public 0 Well 0 Spring 0 Other ft' Site LTAR 044-1-to 0_9-30 POS GN FLOW (.1949): 3 ErD EVAL N METHOD: Auger Boring Pit Cut c:rew.A1, . . 44' SVAiip 05.4 SCANNED gri9"4.---17444 20c/co- 37i P IN# APPLICATION DATE:_ PROPERTY SIZE: PROPERTY RECORDED TYPE OF STEWATER: ewage Process o 44.1,14,04 •- 1 OTHER FACTORS (.1 ?46) .......- SITE CLASSIFICATION -... . . 7EVALUATED BY: /I .; rs--, P. (-- IA .e -4,0 OTHER(S) ...:..i t.; • .W'Y;,,=. AI:AND COUNTY HEALTH DEPARTMENT tchiisioei'14f•Enlrironn4eMal Health 227 Fountainhead Lane / Fayetteville NC 28301 Applicant EDI Af INDSEN • Address:3811 SYCAMORE DAIRY ROAD SITE LOCATION: •7S4a AMESBURY ROAD Fayet*Ilie NC 28303 • Fayattavllfe NC 28301 Prate: (91 " 61-2102 PIN No.: ,0843-07 Als ra tasted, a sofltLiSa evaluation was conducted on this Evaluation Date: 3/23/2006 ENS: A.IMAL A. t tESHAAk was done bjr the attend as set forth M the stews and Rules d��Sewage for Ma Pose of obtaining an Improvement permit. The evaluation waste rat abth Statutes of North Caroline and Ruita .194i - .1960les of Treatment and [disposal Systeme (Article of Cho 71� 1�, Subchapter 18A of tt►a North Carolina A� 30A of the The �g is a summary of the tees for the atta and soli &Val ation of no more than 2} Overall, the soli/site sin toe! that the site of 7846 (two) acres as shown on the plat or site plan. treatment end disposal system (Rub .1947) due to the following: ROAR is UNSUITABLE fora 4rounq absorption .voter sewage to maces an right far 04534:86w: S=St&table, R S.ProvisionalySuraG,e, tJ-,tlrrscrltetle 3 Pis Topography and Landscape Position (Rule :1940) LINEAR CONCAVE. EQUAL TO LESS THAN 5% SLOPE Soli Characteristics (Morphology) (Rule .1941) Strube: GRANULAR, UiFAK SUEANGULAJ BLOCKY AND MASSIVE Torture: LS (FILL), SANDY LOAM, SANDY CLAY LOAM AND SANDY CLAY Caisistence: FRIABLE FIRM; VERY FIRM, STICKY, PLASTIC Minerekgy: MIX CLAY MINERALOGY TO EXPANSIVE CLAY MINERALOGY Sal Vietnam; Conditions (Rule .1942) • CNROMA 2 OR LESS WITHIN 19" FOR BOTH FRONT AND BACK YARDS Soil Depth (Rule .19431 DETERMINATION LIMITED BECAUSE OF A SOIL WETNESS CONDITION Restrictive Hortitona (Rule .1044) MASSNF CLAY HORIZON AT 24" AND 29" Available Space (Rule .1 245) LACK OF AVAILABLE FACE 1N FRONT AND HACK YARD FOR AN ALTERNATIVEAND INNOVATIVE SYSTEM: BECAUSE OF SOIL LIMITATIONS, EXISTING INTER pTOR CRAIN AND EX STING SEPTIC ether Applicable Faces (Rule .194t3) Location of Sanitary Savage systems (Rule .1950) S CANNi - - •• t0on No. 20 -3. ❑ ❑ 11 ❑ ❑ ❑••❑ ❑ ❑ ❑ ❑ ❑ ❑ 0 ❑ ❑ ❑ Print Date: 3/27/20 C1 2 The a� evaluation ❑ ❑ YD one site ev uation In eration a possible modN and modified. atternetfya or innovative and .1 or9). ho ounty HeeNh Dep rtment Environr»ental Health Division ham,`(Rns .1 of .1967 options •*fi overcome the severe site/soli conditions on this it**. determined thet Hotta of the For the maims net forth above, the Ilia la currently cla:silled UNSUI Al&t , and e, ant accofdancs wllh Rub .1948(ca., However, t Al *Wiled es UNSUITABLE may be csssieed �posmr�t •twit not be Slued for KiloM to documentation is.prairtdadthat matte the rrquitsments of Rute .1948Y SUITABLE Kr tt (d). A copy of the rule Is snoyated. You have the tight to request an.inGormnai review of thisthe- . County Health Department. Environmental Wealth Oivislo You Scitat or fErmal mer.at FieaefN� M Department embarking Environmental and Natural Resources Replonal Solis Spc1 A y t an m& re review wmust the N.C. Dvnlbn and of Ciarrlbetiarxt County Health Department, E raqusat for an tntbtrtlei review � �� � � � Cho may s a nvi ermnentei Neagh Division. Yeti may employ a professional p opoaal to overcome the alb based on Ruts .1 engineer or licensed S ton-S1scientist Wastewater Section,' requested t y the Cumberland . 94t. En The mat elth b� nwa tad by the s On-g � County HeaKh Department. Environmental H.allh D�vialon. Pursuant to G.S.130A-24, you may .ilia a petition rbr a contested case hearing with the Oft. of Administrative Hearings, 6714 Mall Center, Raleigh, PLC, 27699-6714. A statement of the a ab pocettqre te� � � . ! have any questions concerning may cenlaet our *Mu dnr - r business houra Monday through FrJday it'om 6O�a 0m b 6. " the appeals �rocedilt8, you Denied BY. AJMA.L A. HESHAAM Signature: 21 n•L—((7. SPECIFICATIONS FOR INITIAL SYSTEM INSTALLATION OF 3-BEDROOM NPDES SINGLE FAMILY SURFACE DISCHARGE WASTEWATER SYSTEM SERVING 7846 Amesbury Road — Fayetteville, North Carolina PREPARED BY: MATT BURDETTTE REVIEWED BY: BRIAN J. KRAYNAK, PE BATEMAN CIVIL SURVEY COMPANY, PC 200 NORTH MAIN STREET HOLLY SPRINGS, NORTH CAROLINA 27540 o aaeaaeeeeaeo ‘v e °°° CAR(J '0ai �o � oo'�_ / sP 1.-4� c, EXPLANATION OF SYSTEM OPERATION AND DESIGN The wastewater disposal system recommended for this site consists of a surface disposal system for a 3-bedroom single-family home containing the following: an existing 1,000 gallon septic tank ; a proposed 1000-gallon re -circulation tank equipped with an AdvanTex re -circulating fixed media filter and controls; a UV disinfection unit with final disposal through a rip rap disposal pad. It should be kept in mind that this system is designed to accommodate a moderate amount of wastewater from the household and that all measures should be undertaken to minimize the volume of water entering the system to include the following precautions: 1. Providing water conserving plumbing fixtures within the house; 2. Making rapid repairs to leaking plumbing fixtures; 3. Developing conservative water use habits on the part of all members of the household; 4. Monitoring and maintaining the system as may be necessary for proper operation; 5. Checking and pumping the septic tank sludge on a regular basis of approximately every two years when garbage grinders are not included; and 6. Insuring proper installation of this system by a competent installation contractor. The system as recommended is intended to provide satisfactory wastewater disposal for the site for a reasonable period of time. Due to the rather complex inter -relationship between soil properties, system installation, wastewater habit patterns of the household, system maintenance, vegetative activity, climate and rainfall, and other factors over which the Engineer has no control, yet which ultimately influence the successful operation of a wastewater disposal system, the Engineer requires that he/she be relieved of any liability that may result from failing or malfunctioning of this system of wastewater disposal. The persons occupying this residence should be familiar with the contents of the Engineer's recommendations. A conference should be held with the Engineer and the installation contractor in attendance prior to beginning any actual construction of the wastewater disposal system in order to answer any questions and to ensure that the installation contractor will make no changes to the recommended system without first obtaining written permission for such changes from the Engineer. The contractor shall coordinate his work schedule with the Designer and with representatives of the health department in order that appropriate and timely inspections of the construction work can be made. SITE PREPARATION REQUIREMENTS 1. The existing wastewater piping system from the residence to the location of the proposed septic tank shall be 4" diameter Schedule 40 PVC sewer pipe laid at 1.0% minimum grade. 2. The existing septic tank is a 1,000 gallon, reinforced precast concrete septic tank with full baffle, and shall be retrofitted with access risers to each chamber from ground level for checking the sludge level and pumping as needed and shall be retrofitted with an effluent filter. Wastewater piping from the septic tank to the location of the proposed re -circulation tank shall be 4" diameter Schedule 40 PVC sewer pipe laid at 1.0% minimum grade. 3. The proposed re -circulation tank shall be a 1,000 gallon, reinforced precast concrete pump tank and shall have easy access to each end of the tank from ground level for maintenance of the pump, control floats and Orenco re- circulating splitter valve provided by Orenco with the AdvanTex treatment system. All piping shall be schedule 40 PVC and constructed as shown on plan sheet 2 of 2. 4. Effluent will pass through the media filter and will collect in the bottom of the media filter pod as shown on plan sheet 2 of 3 and will flow back to the Orenco re -circulating splitter valve. The effluent will be split with a portion flowing to the UV disinfection unit and a portion flowing back to the re- circulation tank. 5. The media filter shall be constructed using materials provided by Orenco and specified on plan sheet 2 of 2. 6. After leaving the pretreatment media filter the wastewater will flow by gravity to a UV disinfection unit. After passing through the UV disinfection unit the wastewater will flow by gravity to a rip rap disposal pad for final dispersion. 7. The contractor shall smooth the disturbed land surfaces after installation of all components of the wastewater treatment and disposal system have been completed, and shall leave the surface neatly shaped to shed rainwater. All disturbed areas and the discharge area shall be seeded with grass and covered with straw. Design Specifications Amesbury Road Facility Type: # of Bedrooms: Daily Flow: Sand Filter Hydraulic loading: Media Filter Size: Sand Media: Effective Size Uniformity Coefficient Dust Content Sand Depth Sand Filter Liner Thickness: Number of Orifices: Size of Orifices: Manifold Length: Manifold Diameter: Supply Line Length: Supply Line Diameter: Supply Line and Manifold Volume: Friction Loss + Fitting Loss: Design Head: Elevation Head: Total Head: Flow: Dose Volume: Length of Dose Number of Doses per Day: Re -circulation Ratio: Control Panel: Pump: Septic Tank Effluent Filter: Septic Tank: Re -circulation Tank: Disinfection: De -chlorination: Single Family Home 3 360 gal/day na gaUday/sq.ft AX 20 na mm na na 0/0 na in na mil na na in na ft na in sch 80pvc na ft na in sch 40pvc na gallons 0.74 ft 4.0 ft 8.0 ft 12.74 ft 7.37 gallons per minute 10 gallons 4 minutes 48 (every 30 minutes) 5:1 Orenco VCOM AXB 1 control panel (or approved equivalent) Orenco P Series P1005 Effluent Pump (or approved equivalent) Orenco Biotube effluent filter (or approved equivalent) 1000 gallon 1000 gallon The disinfector UV unit na RECOMMENDED SCHEDULE FOR SYSTEM MAINTENANCE, 1. The septic tank and recirculation tank should be checked periodically for sludge accumulation and should be pumped out as needed with the sludge being disposed of properly. Check yearly if garbage grinder is included within the wastewater system (not recommended) or check every two years for systems without garbage grinders. 2. Review the owner's manual for the control panel and check control panel for normal function during the weekly system inspection. 3. The discharge area should be protected from stormwater accumulation and from excessive sprinkling of the lawn in the discharge area. Pipe downspout stormwater away from the discharge area. 4. The development of conservative water use habits by all members of the household will greatly enhance the life of this system. 5. Leaking plumbing fixtures should be corrected as soon as possible, or could result in premature failure of the wastewater disposal system. 6. Check the bulb in UV unit monthly and replace annually. 7. The effluent filter at the outlet of the septic tank shall be checked and cleaned as needed during all routine inspections, and at least twice yearly. 8. All rutted or eroded areas that may occur within the area over the surface discharge area shall be carefully filled with suitable loamy soil material. For AdvanTex® Treatment Systems VeriComm® AXB Control Panels Applications VeriComm° AXB1 and AXB2 remote telemetry control panels are used with two -pump operations — recirculation and discharge (on -demand or timed) — for AdvanTex° Treatment Systems. Coupled with the VeriComm web -based Monitoring System, these affordable control panels give water/wastewater system operators and maintenance organizations the ability to monitor and control each individual system's operation remotely, with real-time efficiency, while remaining invisible to the homeowner. VeriComm AXB panels allow remote operators to change system parameters, including timer settings, from the web interface. itum ®lily' ;ill', Typical AXB VeriComm Control Panel Standard Models: VCOMAXB1, VCOM AXB2 To Specify... To specify this panel for your installation, require the following: Basic Control Logic: Three Operating Modes • A "Start-up Mode" for the initial 30 days, during which the system collects trend data to establish operating standards for future reference. • A "Normal Mode" that manages day-to-day functions. • A "Test Mode" that suspends data collection and alarm reporting during installation and service. Data Collection and Utilization • Data logs of system conditions and events, such as pump run times, pump cycles, and alarm conditions. Troubleshooting and Diagnostic Logic • Troubleshooting capabilities that can report suspected failed components, which then trigger Alarms. Advanced Control Logic • Advanced control logic that activates during float malfunctions to diagnose the situation and keep the system operating normally until servicing. Technical Data Sheet Communication and Alarm Management • Remote telemetry capabilities coupled with a web -based moni- toring application (see VeriComm Monitoring System, ATD- WEB-VCOM-1) for communication and alarm management. Updating of point values (including timer settings) and receipt of queued changes during each communication session with host. Communication sessions that occur monthly, at a minimum, and more frequently during alarm conditions. • Multiple methods of communication, as follows: Call -In to VeriComm® Host — Automatic notification to host of "Alarms," which signal fault conditions that need to be addressed immediately (e.g., pump failure). — Automatic notification to host of "Alerts," which signal less critical fault conditions and which trigger the panel's troubleshooting logic and alternative operating mode (e.g., stuck float switch). — Automatic notification to host of "Updates," which include alarm updates or all -clear notifications following Alarms/Alerts, as well as normally scheduled monthly panel reports. — Manual, forced communication from panel to host to.effect an updating of point values and receipt of queued changes. Real -Time Direct Connection to Panel — Manual, direct connection at the site via RS-232 serial port, to allow a local operator real-time access to detailed logged data and the ability to change point values from a laptop. — Manual, forced communication by local operator/homeowner at the site to initiate an auto -answer mode, allowing a remote operator real-time access to detailed logged data and the ability to change point values. During real-time, manual connections, software with open architecture (and password security) is used; no proprietary software is required. VT100 protocol allows access and control from any computer modem (Mac or PC) with a simple communi- cation program (e.g., Windows' HyperTerminal); multilevel password protection in panel ensures that only qualified personnel can access the panel's data. Additional Features • Status light indicators on the board, including... — Flashing green LED for normal operation — Yellow LEDs for status of digital inputs — Red LEDs for status of digital outputs and modem activity • UL-recognized and FCC -approved For more information, try our online demo at www.vericomm.net (no password required). Orenco Systems° Incorporated Changing the Wary the Worrl Does Wastewater' www.orenco.com ATD-CP-VCOM-7 Rev. 2.1 © 11/02 Page 1 of 2 VeriComm® AXB_ Control Panels 1. VeriComm® Remote Telemetry Board 2. Motor -Start Contactors 3. Toggle Switches 4. Control Circuit Breaker 5. Pump Circuit Breakers 6. Fuse 7. Transformer 8. Audio Alarm 9. Visual Alarm 10. Panel Enclosure Standard Components e Technical Data Sheet ou 07 Q0 00 _. 00 1=0 .. �0 00 00 =0I 04 =0 OE Of' . /0 10 9 8 2 4 Feature Specifications 1. VeriCome•Remote Telemetry Unit* 2. Motor -Start Contactors 3. Toggle Switches 4. Control Circuit Breaker 5. Pump Circuit Breakers 6. Fuse 7. Transformer ATRTU-100: 36/18 VAC (center tap transformer), 8 digital inputs, 4 analog inputs, 4 digital outputs, 0 analog ouputs, on -board modem (2400 baud), LED input and output indicators, 1-year battery backup of data and program settings. 120 VAC: 14 FLA, 3/4 hp, 60 Hz; 2.5 million cycles at FLA (10 million at 50% of FLA). 240 VAC: 14 FLA, 2 hp, 60 Hz; 2.5 million cycles at FLA (10 million at 50% of FLA). Single -pole switch, automatic On, with spring -loaded, momentary, manual On. 20 amps, 1 hp. 10 amps, OFF/ON switch. Single -pole 120 VAC, double -pole 240 VAC. DIN rail mounting with thermal magnetic tripping characteristics. 20 amps, OFF/ON switch. Single -pole 120 VAC, double -pole 240 VAC. DIN rail mounting with thermal magnetic tripping characteristics. 120 VAC Primary, 36 VCT @ 0.85A Secondary. 250 VAC, 1A. 8. Audio Alarm 80 dB at 24", warble -tone sound. 9. Visual Alarm 7/8" diameter red lens, "Push -to -silence." NEMA 4,1 Watt bulb, 120 VAC. 10. Panel Enclosure VCOM-AXB1 VCOM-AXB2 Optional Components Feature Pump Run Light Anticondensation Heater Programmable Timer UV Disinfection Compatibility Measures 15.50" high x 13.30" wide x 6.70" deep. NEMA 4X rated. Constructed of UV - resistant fiberglass; hinges and latch are stainless steel. Conduit couplings provided. 120 VAC, 3/4 hp, 14 amps, single-phase, 60 Hz. 240 VAC, 2 hp, 14 amps, single-phase, 60 Hz. Specifications 7/8" diameter green lens. NEMA 4,1 watt bulb, 120 VAC. Self-adjusting; radiates additional wattage as temperature drops. Discharge side timed dosing. UV grounded power circuit and alarm contacts. Product Code Adder PRL HT PT UV * See VeriComm Remote Telemetry Unit (ATD-CP-VCOM-1) and VeriComm$ Monitoring System (ATD-WEB-VCOM-1) for details. ATD-CP-VCOM-7 Rev. 2.1 © 11/02 Page 2 of 2 Control Panel Wiring Diagram Model MVP-S1 PT RO Q4 / -r- —1 HP HP L1 I-' Q3 Q2 Q1 Logo i1 i2 13 i4 i5 i6 N L1 Terminal 171 a El Strip © TL U For float a rangement diagram, see drawing no. "EDW-FAS-10". AS Pump 115 VAC / 1 Hp. 1 Phase / 60 Hz. NOTE: Motors must have internal overload protection Options' PRL X2 W X1 AUTO Options* HT PLi !X2 � X1i c 10 MAN - r t CB t PCB r2 0A Ground Lug Controls Pump Controls Pump Ground Neutral Neutral L1 L1 From Main Power Panel 115 VAC, 1 Phase, 60 Hz. Main disconnect provided by others. *Removal of Alarm / Timer Override Link Rail rrrmmrrr rndi6-2 Ayld ripumprvir Du©©u►ipu Terminal Link Rail Removal of the terminal link rail will separate the high level alarm and override timer functions. Remote Alarm Connections [r' T tRomoto Alarml 0 `LIBht Ala Note: 115VAC signal is present during alarm conditions. i;, Orenco Model AHW or equiv. Key CIS Orenco Systems' Incorporated 814 AIRWAY AVENUE - = Factory Wire •�-- = Field Wire SUTHEGLIN, 08EGON • -- = Altemate Field Wire A = Audio Alarm, 115 VAC 97479-9012 AL = Alarm Light AS = Audio Silence Switch CCB = Controls Circuit Breaker TELEPHONE: Logo= Logic Module M = Motor Contactor i541)459.4449 PCB = Pump Circuit Breaker TL = Terminal Link `Options FACSIMILE HT = Heater PL = Power Light 15411459-2884 PRL = Pump Run Light For MVP-S operation description, see drawing no. "EIN-CP-OP-5". Power Wiring Options Two Circuits 0 O 0 0 O 0 N Ni m LEI (0 (0 d Factory default. Wire as shown. One Circuit Wire Nut Use one wire nut to connect the pole of the pump circuit breaker together with the controls breaker and with the incoming Li power line. Use another wire nut to connect the neutral block of the pump with the controls neutral block and with the incoming neutral line. EDW-WD-S-93 Rev. 5.1 © 03/03/04 r series High -Head Effluent Pumps Applications Our submersible High -Head Effluent Pumps are designed to transport screened effluent (with low TSS counts) from septic tanks or separate dosing tanks to collection and treatment sys- tems. All our pumps are constructed of lightweight, corrosion - resistant stainless steel and engineered plastics; all are field - serviceable and repairable with common tools; and all standard P Series models are UL and CSA listed for use with effluent. Orenco High -Head Effluent Pumps are used in a variety of appli- cations, including drainfields, packed bed filters, mounds, aero- bic units, effluent irrigation, effluent sewers, wetlands, lagoons, and more. 77 cu cr Franklin motor Actual view CIS Orenco Systems° Incorporated 1-800-348-9843 Discharge connection Bypass orifice Shell casing Suction connection Technical Data Sheet Features/Unique Specifications To specify this pump for your installation, require the following: • Minimum 24-hour run -dry capability without water lubrication; • 1/8-inch bypass orifice to ensure flow recirculation for motor cooling and to prevent air bind; • Floating stack design to protect against upthrust and increase pump life; • Repairable (nondisposable) liquid end for better long-term cost of ownership; • Corrosion -resistant construction; • Franklin motor rated for continuous use and frequent cycling; • Type SOOW motor cable (suitable for Class I, Division 1 and 2 applications); • Optional 5-year extended warranty against defects in materi- als or workmanship. Standard Models See specifications (on back) for a complete list. Cali Orenco or your nearest distributor for three-phase specifications. Nomenclature P❑❑❑❑❑❑-❑❑ TCord length: Blank = 10' 20 = 20' 30 = 30' Voltage: 1 = 115 (1/2 hp only) 2 = 230 Phase: 1 = single-phase 3 = three-phase Horsepower: 05 = 1/2 hp 07 = 3/4 hp 10 = l hp 15 = 1-1/2 hp 20 = 2 hp 30 = 3 hp 50 = 5 hp Nominal flow (gpm): 10 20 30 50 Pump (P Series) NTD-PU-P-1 Rev.1.2, © 2/03 Page 1 of 4 P Series High -Head Effluent Pumps (continued) Specifications Hp' Amps2 Nom. Flow (gpm) Discharge (in.) Length (in.) Ma' (in.) Cable' Listings Rated Cycles/Day P1005 0.50 12/6 10.0 1.25 22.50 20 SOOW UUCSA 300 P1007 0.75 8.0 10.0 1.25 25.00 22 SOOW UUCSA 300 P1010 1.00 9.8 10.0 1.25 28.00 24 SOOW UUCSA 100 P2005 0.50 12/65 20.0 1.25 22.75 20 SOOW UUCSA 300 P2010 1.00 9.8 20.0 1.25 27.00 25 SOOW UUCSA 100 P2015 1.50 13.1 20.0 1.25 32.50 28 SOOW UUCSA 100 P3005 0.50 12/6 30.0 1.25 21.50 22 SOOW UUCSA 300 P3007 0.75 8.0 30.0 1.25 24.00 24 SOOW UUCSA 300 P3010 1.00 9.8 30.0 1.25 26.50 27 SOOW UUCSA 100 P3015 1.50 13.1 30.0 1.25 32.50 29 SOOW UUCSA 100 P3020 2.00 13.2 30.0 1.25 34.50 25 SOOW CSA 100 P3030 3.00 17.0 30.0 1.25 43.75 44 SOOW CSA 100 P3050 5.00 27.5 30.0 1.25 67.00 66 SOOW CSA 100 P5005 0.50 13.2/6.6 50.0 2.00 20.50 22 SOOW UUCSA 300 P5007 0.75 8.0 50.0 2.00 24.75 24 SOOW UUCSA 300 P5010 100 9.85 50.0 2.00 28.00 27 SOOW UUCSA 100 P5015 1.50 13.1 50.0 2.00 33.25 29 SOOW UUCSA 100 P5030 3.00 17.0 50.0 2.00 49.00 48 SOOW CSA 100 P5050 5.00 27.5 50.0 2.00 63.50 50 SOOW CSA 100 AdvanTex Pump PAX 0.50 12/6 10.0 1.25 19.75 18 SOOW UUCSA 300 1. All 1/2 horsepower pumps are available in 115 and 230 voltage models. 2. Maximum sustained amperage (service factor load). The paired amperage numbers for 1/2 hp pumps are for 115 and 230 volts respectively. All other numbers are for 230 volts. 3. Minimum liquid level. 4. SOOW type is suitable for Class I, Division 1 and 2 applications. 5. Actual running amperage may exceed the motor's nameplate amperage by 20% (UL778). Materials of Construction Discharge: Fiberglass -reinforced thermoplastic or stainless steel (P50) Discharge Bearing: Nylon polymer Intake Screen: Polypropylene Suction Connection: Fiberglass -reinforced thermoplastic Drive Shaft: 7/16 inch hexagonal stainless steel Diffusers: Polycarbonate Coupling: Stainless steel Impellers: Acetal Thrust Pads: (Proprietary) Shell: Stainless steel Motor: Franklin motor exterior constructed of stainless steel. Constant lubrication through water -filled design. Hermetically sealed motor assures moisture -free windings. All thrust absorbed by Kingsbury type thrust bear- ing. Rated for continuous duty. Protected against thermal overload and equipped with surge arrestors for added security. NEMA standard 2-wire or 3-wire (2, 3, and 5 hp) motor with ground. Control box required for 3-wire motors. NTD-PU-P-1 Rev. 1.2, © 2/03 Page 2 of 4 P Series Pump Curves Technical Data Sheet Using a Pump Curve A pump curve helps you determine the best pump for your system. Pump curves show the relationship between flow (gpm) and pressure (TDH), providing a graphical representation of a pump's optimal performance range. Pumps perform best at their nominal flow rate —the value, measured in gpm, expressed by the first two numerals in an Orenco pump nomenclature. 400 350 300 mV • 250 Z • 200 U_ 0 • 150 I. 100 50 P1010 P10 Series 1/2 hp to 1 hp P1005 with 1/4 Dow controller l � I 1 3 6 9 12 Gallons per Minute (gpm) Orenco Systems' Incorporated 1-800-348-9843 15 400 350 300 4-0 250 O Z 200 c3 C 150 1-6 100 50 P20 Series 1/2 hp to 1-1/2 hp P2015 -rj P2005 k ■■ I ■ TIM ■1■ 1 III Ern 1 I V ■.■■ 11 lim II 11 i ■■u■� ■■.■■ MI 5 i 1 10 15 20 Gallons per Minute (gpm) 25 I 30 a. NTD-PU-P-1 Rev. 1.2, © 2/03 Page 3 of 4 300 250 200 ,c Z 150 E o� 0 100 I. 50 0 700 600 500 v ct .c 400 i 300 :9 200 100 1 ! 1, II 11 i::I i ;I::1, i 1! I ! 1 1 i P30 Series I I I I ' I 1/2 hp to 1-1/2 hp I i P3015 'I I i ii 1 I! I. I I I II 11 IiI I ! I_ — P3010 ! i 1 I i 1 I I T I f Ii lil i 11 ii !1 I ' P3007 I i I li I it 1I I P3005 I! I I I Ii lil I _ I I II IIi I l i 1 I i ;T---i II !!I II i I it 1 I I IT IT 1 ii 1 I I 'I I ! .I 0 5 10 15 20 25 30 Gallons per Minute (gpm) 35 40 P3050 P30 & P50 Series 2hpto5hp CSA listing only 10 20 30 40 50 Gallons per Minute (gpm) 60 70 160 140 120 c 100 80 (.3 E 0 60 40 20 150 125 25 0 P5015 P50 Series 1/2 hp to 1-1/2 hp P5010 P5007 P5005 10 20 30 40 50 60 70 Gallons per Minute (gpm) AdvanTex® Pump 1/2 hp PAX 1 0 3 6 9 12 Gallons per Minute (gpm) 15 NTD-PU-P-1 Rev. 1.2, © 2/03 Page 4 of 4 Biotube® Pump Vault Applications Orenco's patented* Biotube Pump Vaults are ideal for filtering and transporting effluent from septic tanks or separate dosing tanks in effluent pumping systems. They prevent large solids from leaving the tank, dramatically improving wastewater quality and extending the life of downstream treatment systems. Each pump vault houses either one (Simplex) or two (Duplex) High Head Effluent Pumps, discharge assembly(ies), Biotube filter cartridge, float switch assembly, and float stem bracket. Pump(s), float switch assembly, and discharge assembly(ies) are ordered separately. Orenco's Biotube Pump Vault comes with Biotube filter cartridge, float stem bracket, and support pipes The unique Biotube filter cartridge provides a large filter surface area (see specs. on back) in a small space, to resist clogging while providing maximum long-term protection. 'Covered by patent numbers 5,492,635 and 4,439,323 APS-BPV-1 Rev. 2.2 © 9/01 Standard Features & Benefits • Installs quickly in new or existing tanks • Easy access design allows filter car- tridge removal with- out pulling the pump or vault; simplifies filter inspection and maintenance • Patented Biotube filter has several times the filtering capacity of other pump vaults • Removes approxi- mately two-thirds of suspended solids, on average • Accommodates Simplex or Duplex configuration, for use with one or two pumps • Float stem bracket allows easy removal and adjustment of float assembly • Sturdy, molded polyethylene and corrosion -proof construction ensure long life Biotube Filtering Effluent from the relatively clear zone of the septic tank, between the scum and sludge layers, enters the Biotube Pump Vault through inlet holes in the housing. Effluent then Process enters the annular space between the housing and the Biotubes, utilizing the Biotubes' entire surface for filtering. Particles larger than the Biotube's mesh are prevented from leaving the tank. os� Orenco Systems• Incorporated Changing the Way the World Does Wastewater$ www.orence.com Model Code for Ordering Biotube® Pump Vault PVU DO- O0 D0 Indicates inlet hole height: (inches) Cartridge height: 18", 24", 36" standard Vault height: 57", 66"-96" in 6" increments Universal Pump Vault Easy access design allows filter cartridge removal without pulling the pump or vault; simplifies filter inspection and maintenance Biotube Cartridge Effective Filter Surface Area Cartridge Height 12" Diameter 18" 24" 36" 15.5 ftz 20.6 ft2 30.9 ftz Orenco Biotube Pump Vault is available in standard and customized configurations. Contact Orenco or your nearest distributor for sizing recommendations. Tank Access and Riser Diameter Biotube Pump Vault Components Vault height Inlet hole height Discharge pipe Vault Flow inducer Biotube® handle assembly Float switch assembly (ordered sep.) `` Biotube® filter cartridge Inlet holes High head effluent pump(s) (ordered sep.) To Order Call your nearest Orenco Systems®, Inc. distributor. For nearest distributor, call Orenco at 1-800-348-9843 or go to www.orenco.com and click on "Distributor Locator." © Orenco Systems® Inc 2001 Biotube Series Tank Access Dia. Tank Access Dia. Riser Dia. Minimum Recommended Minimum PVU w/Simplex Pump 19" 20" 24" PVU w/Duplex Pumps 19" 20" 30" Distributed By: Residential Biotube® Effluent Filters Applications Our patented* 4" Biotube Effluent Filters, Biotube Jr., Biotube Insert Filters, and Biotube Base Inlet Filters are ideal for residential septic tanks. They prevent Large solids from leaving the tank, dramatically improving wastewater quality and extending the life of residential drainfields. 4'' Biotube Effluent Filter 4" Biotube Jr. (4" Biotube cartridge available separately as Insert Filter) 8"Base Inlet Filter 12"Base Inlet Filter Orenco superior effluent filters resist clogging better than all other brands. Our stan- dard, full-sized 4" Biotube Effluent Filter provides maximum long-term protection in a complete package, with housing. Our 4" Biotube Jr., at half the size of our standard model, has more filtering capacity than the full-sized filters sold by other manufacturers. For tanks with existing outlet tees, the Jr. Insert Filter is ideal. And for low profile tanks, there's the Base Inlet Filter. Covered by patent numbers 5,492,635 and 4,439,323 To Order Ca11 your nearest Orenco Systems®, Inc. distributor. For nearest distributor, call Orenco at 1-800-348-9843 or go to www.orenco.com and click on "Distributor Locator." APS-Fr 1 Rev. 3.1 © 1/03 Orenco Systeme, Inc. Standard Features & Benefits • Has 5-10 times more flow area than other brands, so lasts many times longer between clean- ings, increasing homeowner satis- faction Installs in minutes inside new or existing tanks; extendable tee handle for easy removal Optional Features & Benefits Alarm available, to signal the need for cleaning How modulating discharge orifices available to limit flow rate leaving tank, mitigating surges and increasing retention time Custom and commercial sizes available • Easy to clean by simply hosing off whenever the tank needs pumping • Removes about two-thirds of sus- pended solids, on average, extending drainfield life • Corrosion -proof construction, to ensure long life Biotube Filtering Process Effluent from the relatively clear zone of the septic tank, between the scum and sludge layers, horizontally enters the Biotube Effluent Filter. Effluent then enters the annular space between the housing and the Biotubes, utilizing the Biotubes' entire surface for filtering. Particles larger than the Biotube's mesh are prevented from leaving the tank. Orenco Systems'' Incorporated Changing the Way the GG'odd Does Waste,vatei" www.orenco.com www.vericomm.net Nomenclatures 4" Biotube Filter (standard) FT❑❑04❑❑-❑❑MA- �For customized options (e.g., NC indicates North Carolina regions) Indicates float bracket attached Indicates flow modulation plate installed Cartridge height, 28" and 36" are standard Housing height, 36" and 44" are standard Indicates filter diameter (inches) W= fits 3034 outlet pipe S = fits schedule 40 outlet pipe P= 1/16" filtration Blank = 1/8" filtration Biotube effluent filter series 8", 12" Biotube Filter (base inlet model) FT00022-14B0 TAdd codes for standard options: A = float bracket Base inlet model Cartridge height, 14" standard Housing height, 22" standard Indicates filter diameter (inches) 08 = 8" 12 = 12" P = 1/16" filtration Blank = 1/8" filtration Biotube effluent filter series 4" Biotube Jr. (includes cartridge and housing) FTJ❑❑0418MA- - For customized options (e.g., NC indicates North Carolina regions) Indicates float bracket attached Indicates flow modulation plate installed Cartridge height (inches) Indicates filter diameter (inches) W = fits 3034 outlet pipe S = fits schedule 40 outlet pipe P = 1/16" filtration Blank= 1/8" filtration Jr. series Biotube effluent filter series 4" Jr. Filter Insert (cartridge only) FTi 00418-0- T For customized options (e.g., NC indicates North Carolina regions) W = fits 3034 outlet pipe S = fits schedule 40 outlet pipe Cartridge height (inches) Indicates filter diameter (inches) P = 1/16" filtration Blank= 1/8" filtration Insert series 4" Biotube Effluent Filter 4" Biotube Jr. Extendible PVC handle Stainless steel set screws Top seal plate Air vents Biotube filter cartridge Solid base Filter housing Distributed By: Biotube effluent filter series