Loading...
HomeMy WebLinkAbout20210695 Ver 1_Pre-Filing Acknowledgement Email_20210416Strickland, Bev From: laserfiche@ncdenr.gov Sent: Friday, April 16, 2021 4:45 PM To: Lucas, Ronald G, Jr. Cc: Steenhuis, Joanne Subject: Pre -Filing Meeting Request Acknowledgement - SCX Railroad, Wilmington "Beltline" Updrades - 20210695 Ver 1 Attachments: DWR Pre -Filing Meeting Request Form.pdf The North Carolina Division of Water Resources has received the Pre -Filing Meeting Request Form for SCX Railroad, Wilmington "Beltline" Updrades that you submitted on (date). The ID number for that project is 20210695, Version 1. Reviewer Contact Information: Reviewer: Joanne Steenhuis Reviewer Email: joanne.steenhuis@ncdenr.gov Reviewing Office: Wilmington Regional Office - (910) 796-7215 When you submit your application please upload a copy of the attached document in this email. For internal use only: Transportation Project This email was automatically generated by Laserfiche workflow. Please do not respond to this email address, as responses are not monitored. i DWR Pre -Filing Meeting Request Form ID#* Regional Office* Reviewer List* 20210695 Version * 1 Wilmington Regional Office - (910) 796-7215 Joanne Steenhuis Pre -Filing Meeting Request submitted 4/6/2021 Contact Name * Contact Email Address* Project Name* Project Owner* Project County* Owner Address: Ron Lucas, P.E. rglucas@ncdot.gov SCX Railroad, Wilmington "Beltline" Updrades NCDOT New Hanover Street Address NCDPT Rail Division Address Line 2 862 Capital Blvd. City State / Rovince / Region Raleigh NC Fbstal / Zip Code Country 27604 USA Is this a transportation project?* ( Yes r No Type(s) of approval sought from the DWR: fJ 401 Water Quality Certification - I— 401 Water Quality Certification - Regular Express I— Individual Permit I— Modification ✓ Shoreline Stabilization Does this project have an existing project ID#?* (' Yes r No Please list all existing project ID's associated with this projects.* P-5740 Do you know the name of the staff member you would like to request a meeting with? Joanne Steenhuis, if needed Please give a brief project description below and include location information. * Wilmington CSX Railroad "Beltline" Improvement Project — (P-5740) - The purpose is to increase the train speed between CSXs Davis Yard in Navassa (Brunswick County) and 2nd Street in Wilmington, as well as improving crossing safety. A program of tie and rail rehabilitation/replacement was undertaken to bring the line of railroad from Class 1 to Class 2 Federal Railroad Administration (FRA) track safety designation. The improved track safety was coupled with the increase in train speed from 10 mph to a 25-mph maximum. One short sections of curve realignment was proposed near the Love Grove community. Switches were upgraded as well. Along with the rail improvements came improvements to the highway grade crossing surfaces and signals. The project closed three existing atlgrade crossings (Martin Street near Hooper Street, Martin Street portion near 6th Street, and Clay Street) and improved 23 existing atlgrade crossings. Two short connector roads (approximately one block long) were built for connectivity associated with the crossing closures. Present plans indicate about 0.52 acres of wetland impact for installation of an additional signal and associated access road and about 91 feet of stream impact at the rail realignment. Moffatt & Nichol staff completed the NEPA compliance with an FRA Categorical Exclusion. The work included Public Involvement, as well as detailed Section 106 Cultural Resources coordination. Work also included a Natural Resources Technical Report (NRTR), Preliminary Jurisdictional Assessment (PJD) and a Community Impact Assessment (CIA) in accordance with FRA and NCDOT standards. Please give a couple of dates you are available for a meeting. 4/20/2021 Please attach the documentation you would like to have the meeting about. DWG_20210308_WILMINGTON_NC_PERMIT... 4.05MB Final Stream Call letter P-5740.pdf 2.47MB final signed PJD form.pdf 5.13MB pdf only By digitally signing below, I certify that I have read and understood that per the Federal Clean Water Act Section 401 Certification Rule the following statements: • This form completes the requirement of the Pre -Filing Meeting Request in the Clean Water Act Section 401 Certification Rule. • I understand by signing this form that I cannot submit my application until 30 calendar days after this pre -filing meeting request. • I also understand that DWR is not required to respond or grant the meeting request. Your project's thirty -day clock started upon receipt of this application. You will receive notification regarding meeting location and time if a meeting is necessary. You will receive notification when the thirty -day clock has expired, and you can submit an application. Signature .x,o.. - .e ..,..R.,.. 4.+r2rz' Submittal Date 4/6/2021