Loading...
HomeMy WebLinkAboutNCG170269 Email re Outfall Updates_20210331McCoy, Suzanne From: Todd Wegenast <Todd.Wegenast@coats.com> Sent: Wednesday, March 31, 2021 2:22 PM To: McCoy, Suzanne Cc: John Moss; Emrah BILGIN Subject: [External] Coats American Sevier - Stormwater Permit NCG170269 Updates CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Suzanne, I have submitted a copy of the name/ownership form for the Coats American facility in Marion, NC (NCG170269). Many of the site contacts in the database were old and have been updated with the current site contacts. I was not able to download the form. Can you send me a copy of the form as submitted? The billing contact should be John Moss and he is also listed in the attached form as the site contact. The site has the following outfalls. Note: only 1 outfall is listed in the Owner Verification Report in the database. Receiving Body Limekiln Creek Limekiln Creek Limekiln Creek Limekiln Creek Limekiln Creek Limekiln Creek Un-named tributary Un-named tributary Un-named tributary A description of each outfall is below. 1 Storm water Exposure Item Associated Location Comments Outfall Receiving Docks Outfall #1 West and South Two docks are covered with a roof side of building structure. Bulk Ethanol Tanks Outfall #1 South side of ASTs equipped with secondary building. containment Trash compactor Outfall #1 South side of Compactor is enclosed and located building inside garage area under cover A/C Cooling Towers (11) Outfall #6 East side of No secondary containment building Loading/Receiving Dock Outfall #7 South side of Uncovered building Bulk Specialty Engineered Outfall #7 South side of Totes stored outside uncovered on Yarns (SEY) Lube Storage building concrete pad Maintenance Receiving Dock Outfall #7 South side of building Duke Power Transformer Outfall #7 South side of Area is routinely inspected building Coats Village Transformer Outfall #7 South side of Area is routinely inspected building Paint thinner — Outfall #7 South side of Paint and paint thinners stored Carpenter Shop building inside carpenter shop Empty Barrel Storage Outfall #7 South side of Drums are no longer stored outside building in this area Silicone ASTs Outfall #7 South side of ASTs equipped with secondary building containment Scrap Metal Outfall #7 South side of Scrap metal stored on ground building uncovered Wooden Pallets Outfall #7 South side of Wooded pallets stored on ground building uncovered Hydrogen Peroxide AST Outfall #7 South side of AST equipped with secondary building containment No.2 Fuel Oil ASTs Outfall #7 South side of ASTs equipped with secondary building containment Propane Tank Outfall #7 South side of Release of propane would dissipate building to the atmosphere. Bulk Chemical Tote Storage Outfall #7 South side of Totes stored inside Boiler Room in building Tank Farm area. Flammable storage shed Non -hazardous Waste Empty Outfall #7 South side of Drums stored inside undercover. Drum Storage building Hazardous Waste Storage Outfall #7 South side of Drums stored inside storage shed. Area building Yard Storage Building Outfall #7 South side of Storm water could flow underneath building covered shed Tank Farm Chemicals Outfall #7 Inside main Drums and totes stored inside building facility. Ash Sluice Pond/WWTP Outfall #S East of building Sluice ponds no longer in service Burn Site Outfall #9 East of building Heavily overgrown with brush (1) 300-Gallon Diesel Tank Outfall C Western portion Diesel tank is located at fire pump of property inside a building. Chemical Storage Building Outfall #7 South side of Virgin product is stored in drums and building totes on racks inside the building. The approximate lat/long for each outfall is below # Lat Long 1 35.788402 -82.031472 2 35.788634 -82.030072 3 35.789215 -82.028643 4 35.789632 -82.027414 5 35.790096 -82.026214 6 35.790561 -82.025299 7 35.789203 -82.024339 8 35.790770 -82.023727 9 35.790067 -82.019276 Please let me know if you need any further information. Thank you, Todd J. Wegenast Environmental Compliance Manager - Coats North and Central America Cluster 850-545-8142 todd.wegenast@coats.com The information contained in this communication (including any attachments transmitted with it) is confidential and may be privileged and the views, conclusions and other information expressed herein are not necessarily the views of or endorsed by Coats Group plc unless such information is transmitted in the normal course of its business. It is for the exclusive use of the intended recipient(s). If you have received this message in error and you are not the intended recipient(s), please notify us by email (Technology.Supportdesk@coats.com) or telephone our technical support helpdesk at Coats Group plc. +44 (0)208 606 6656 (available 24 hours a day, 7 days a week) and then delete the email and any copies of it including any attachments thereto. Any distribution, copying or use of this communication or the information contained herein if received in error is strictly prohibited. Coats Group plc will not be liable for direct, special, indirect or consequential damages arising from the alteration of the contents of this message by a third party or as a result of any virus being passed on. All references to "Coats Group plc" includes all of its subsidiaries and associated companies. Coats Group plc is registered in England and Wales under company registration number 00103548 having its registered office at 4 Longwalk Road, Stockley Park, Uxbridge UBI 11FE.