Loading...
HomeMy WebLinkAbout NCG170358_Email re Outfall Updates_20210331McCoy, Suzanne From: Todd Wegenast <Todd.Wegenast@coats.com> Sent: Wednesday, March 31, 2021 1:00 PM To: McCoy, Suzanne Cc: Don Hager; Tommy Jones Subject: [External] Coats HP Pharr - Follow Up Flag: Flag Status: Follow up Completed Stormwater Permit NCG170358 Updates CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Suzanne, Attached is a copy of the name/ownership form for the Coats HP facility in McAdenville, NC (NCG170358). The billing contact should be Tommy Jones and he is also listed in the attached form as the site contact. The site has the following outfalls. Note: only 1 outfall is listed in the Owner Verification Report in the database. # Receiving Body South Fork Catawba River 2A South Fork Catawba River 213 South Fork Catawba River 2C South Fork Catawba River South Fork Catawba River A description of each outfall is below. Outfall #1 (Drainage Area 1) Drainage Area 1(±4.90 acres) consists of an area along the eastern property boundary which discharges to Outfall 1 located on the southwest portion of the property. The drainage area includes the employee parking lot, eastern chiller room, boiler room, electrical substation owned by Duke Energy, and runoff from the manufacturing building roof. Stormwater will flow via sheet flow eastward towards Outfall #1. An underground pipe located near the Duke Energy substation collects stormwater from the boiler room and substation north of the manufacturing building and directs it towards Outfall #1. Outfall #1 discharges east towards the South Fork Catawba River. Outfall #2A, 213, & 2C (Drainage Area 2) Drainage Area 2 (±6.79 acres) consists of the area northeast and south of the manufacturing building. This Drainage Area consists of the Tank Containment Area (eastern portion only), northern employee parking lot, Chiller Room, and Small Compressor Room to the northeast of the manufacturing building, and the cooling tower and employee parking lot to the south of the manufacturing building. Stormwater will flow east via sheet flow towards a series of storm drains which discharge off the property at Outfalls 2A, 213, or 2C. Stormwater runoff at areas south of the manufacturing building will flow via sheet flow east towards a storm drain located southeast of the manufacturing building. The storm drain will then direct stormwater north towards another storm drain and then will discharge through Outfalls 2A, 213, or 2C. Any stormwater from this area that is not captured by the southeastern storm drain will flow off the property via sheet flow. Outfalls 2A, 213, and 2C will discharge east towards the South Fork Catawba River. Outfall #3 (Drainage Area 3) Drainage Area 3 (±9.06 acres) consists of the area along the western property boundary which discharges to Outfall 3. This Drainage Area consists of the Tank Containment Area (western portion only), Oil Storage Shed, trash compactor, metal dumpster, north employee parking lot and run-on from the adjacent property to the west and Interstate 85 to the south. Stormwater in Drainage Area 3 is conveyed via sheet flow towards Outfall 3 and a small detention pond. Surface overflow from the small detention pond will discharge to the large detention pond which then discharges into a ravine flowing east. The ravine will eventually discharge to the South Fork Catawba River. The snapshot below shows the lat/long for each outfall. ---------- Outfall 2C - outran 2B Wit;, .. Latitude: 35° 15' 56.834" N Latitude: 35' 15' 56. 659" N a f Longitude: $1 ° 4' 44.869" W Lan itude: 81 4' 44.877" Outfarf 2A Latitude: 35' 15' 56.450" N Longitude: 81 ° 4' 44.853"' Outfall 3 - _ Latitude: Ou all 3 851" N South Fork Catawba River - I Lo► aitude: 81 ° 4' 53. 973" t SEAL MARSHA aALL ARRANCH o,C�yoIV ar 0U#Fa8 1 Latitude: 35° 15' 55.630" N Longitude: 81° 4' 43.260" W` s` "fgry sr - N_ I Please let me know if you need any further information. Thank you, Todd J. Wegenast Environmental Compliance Manager - Coats North and Central America Cluster 850-545-8142 todd.wegenast@coats.com The information contained in this communication (including any attachments transmitted with it) is confidential and may be privileged and the views, conclusions and other information expressed herein are not necessarily the views of or endorsed by Coats Group plc unless such information is transmitted in the normal course of its business. It is for the exclusive use of the intended recipient(s). If you have received this message in error and you are not the intended recipient(s), please notify us by email (Technology. Supportdesk@coats.com) or telephone our technical support helpdesk at Coats Group plc. +44 (0)208 606 6656 (available 24 hours a day, 7 days a week) and then delete the email and any copies of it including any attachments thereto. Any distribution, copying or use of this communication or the information contained herein if received in error is strictly prohibited. Coats Group plc will not be liable for direct, special, indirect or consequential damages arising from the alteration of the contents of this message by a third party or as a result of any virus being passed on. All references to "Coats Group plc" includes all of its subsidiaries and associated companies. Coats Group plc is registered in England and Wales under company registration number 00103548 having its registered office at 4 Longwalk Road, Stockley Park, Uxbridge UB11 1FE.