Loading...
HomeMy WebLinkAboutwq0039143_Application (FTSE)_20210304 (2)State of North Carolina DWR Department of Environmental Quality Division of Water Resources Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: '""Quo } ! ! 4J - _ ... __ _ (to bccomplocd by DWttl y All items mast be cum nleted or the analication will be returned I. APPLICANT INFORMATION. 1. Applicant's name: I lesia Nueva Jerusalen (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ® Corporation ❑General Partnership ❑Privately-Otvned Public Utility ❑ Federal ❑ State/County ❑ Municipal ❑ Other 3. Signature authority's name. Juan Carlos Morales per 15A N AC 0?T .0- - i 06rb) Title: De eloper 4. Applicant's mailing address: 1303 Claymore Drive NC Dept of Environmental Quality City: Gamer State: NC Zip: 27529- M 5. Applicant's contact information: MAR -4 2021 Phone number: 9l9 330-7072 Email Address: bautista'.80 live.com Raleigh Regional Office II. PROJECT INFORMATION: I . Project name: ISlesia Nueva Jerusalen 2. Application/Project status: ❑ Proposed p (New Permit) ®Existing Permit/Project If a modification, provide the existing permit number: WQ0039143 and issued date: Anril 17, 2017 If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Johnston 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.5236° Longitude:-78.578I 5. Parcel ID (if applicable): 162400- 5-4 27 (or Parcel 1D to closest downstream sewer) 111. CONSULTANT INFORMATION: L Professional Engineer: Gary J. McCabe License Number: 032614 Firm: Red Line Enzineerin2, PC Mailing address: 123 Raleigh Street City: Fu uav-Varina State: NC Zip: 27526-_ Phone number: 9l9 779-I 851 Email Address:-mccabe rlenc.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Johnston County WWTF Permit Number WOCS00060 Owner Name: Johnston Count V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ0017015 Downstream (Receiving) Sewer Size: 6 inch Svstcm Wide Collection stem pee —lit hiu�nf erfti it a l: 'ahls : WQCS00060 Owner Name(s): J hn ton County FORM: FTA 04-I6 Page 1 of 5 V1. GENERAL REQUIREMENTS L If the Applicant is a Privately -Owned Public utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes []No [OWA 2. If the Applicant is a Developer of lots to be sold, has a Deve) er's O erationall A Eonent FORM DL_V1 been attached? ❑ Yes []No ®NIA 3, If the Applicant is a I [or�tie_Prnl�x!.rt�. Q}vgers' Association, huw an Ott rational Freemen" t; FO[iM: HOA}been attached? ❑ Yes ❑No ®NIA 4. Origin of wastewater (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparatiomservice ❑ Hotel and/or Motels ❑ School preschool e' day care ❑ Medical 'dental.: veterinary facilities ❑ Swimming Pool : Clubhouse ❑ Food and drink facilities ® Church ❑ Businesses r offices El swimming Pool/Filter Backwash ces J factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100 °/o Domestic,'Commercial _ % Commercial % Industrial (See I SA NCAC.0>T .Oil! , ) .Is there a Pretreatment Program in effect? [:]Yes ❑ No 6. Has a flow reduction been approved under 15A N.C'AC 0 T _01 14( ? 0 Yes ® No )+ If yes, provide a co of now reduction aRproval letter 7. Summarize wastewater generated by project: Establishment Type (see 0 AI tdt y Church Wout kitchen, daycare or camps Daily Design Flow'.b INo. of Units Flow 3 gal/seat gall gal/ gal/ gap gal/ 180 Total 540 GPD GPD GPD GPD GPD GPD 540 GPD a See . A N Ati 42T_,01 I-1(t)LO),e)t 1) d a 1_21 for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in Gam% 42_ A-d , b Per 15A NCAC 02T .01 I4(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01 141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 540 GPD (per i5A NCA( 02 r.01.14) D Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-I6 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - U2T .f1,115 & tiIDC j ravity S4�wersl: 1, Summarize gravity sewer to be permitted: > Section ❑ & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria Section III contains information related to minimum slopes for gravity sewer(s) Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC Vill. PUMP STATION DESIGN CRITERIA (If Applicable) --02T.03tIS & MDC (Pum p Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT f , Pump station number or name: Iglesia Nueva Jerusalen PS 2_ Approximate Coordinates (Decimal Degrees): Latitude: 35.5241Longitude; -78. 781 3_ Design flow of the pump station: 0.0000540 millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): 5¢ gallons per minute at 39 feet total dynamic head (TDH) 5_ Summarize the force main to be permitted (for this Pump Station): Size {inches) TLength (feet) Material 265 PVC 6. Power reliability in accordance with I iA NCAf�02i .0__.. 305ih&D: ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(13)_ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day- ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. D If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04- f 6 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 &. 15A NCAC 02T .0305(t)): 1. Does the project comply with all separations found in f A NCAC 021- .0305jtJ2K_w ®Yes ❑ No 3 SA. NCAC 02T.030S(LIJ contains alternatives where separations in 03T�030;�tl cannot be achieved. "Stream classifications can be identified using the Division's N(. Surface Water Classifications �reb a �e D If noncompliance with 02T.005 or }, see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes Seethe Division's draft separation requirements for situations where separation cannot be meet ❑ No ❑ NSA No variance is required if the alternative design criteria specified is utilized in design and construction > As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 0213.0200? ® Yes ❑ No ❑NSA This would include Trout Buffered Streams per fA AC ZB.p� 3 4. Does the project require coverage/authorization under a 404 Nationwide or ❑ Yes ® No individual permits or 401 Water Quality Certifications? Information can be obtained from the 401 & Buffer P i tine Branch 5. Does project comply with 15A Nt.AC 0,.)T.O O...i 5(cX6) (additional permits/certifications)? ❑ Yes ® No Per 15A NCAC 02 T' OIO�fc" r{6i, directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15 A NCAC 02'f .0402. "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer Positioned parallel to streambanks that is subject to erosion that underm ines or deteriorates the sewer. ❑ Yes ®No []N/A If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall he Inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permilee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permithne of Pump titatioas and force Mains S latest version), and the Qfavil _SewerMinim m Design Criteria 1Lteaversio as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Aipproval of the request is re aired prior to submittal of the Fast Track Anylication and supporting documents. Professional ?�ZEngineer' ertificati I' ` _ _ attest that this application for (Prof io Eng neer's name from Application Item III.I.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-2I5.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Cla7l demeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. .......... _ North Carolina Professional Engineer's seal, signature, and date: a SEAL 032614 f J MCC 3. Applicant's Certification 7' " l� tt Pp per !SA NCAC 02T A106(b)� I' attest that this application for (Signature Authority's name & title ram Application Item 13.) _ has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. 1 also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and .143-215.6i3, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to S25,000 per violation. Signatures Date: 0 FORM: FTA 04-16 Page 5 of 5 State of North Carolina DWR Department of Environmental Quality Division of Water Resources Division of Water I5A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Resources INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION This application is for sewer extensions involving gravity sewers, pump stations and force mains, or any combination that has been certified by a professional engineer and the applicant that the project meets the requirements of I5A NCAC_021 and the Division's Minimum Design Criteria and that plans, specifications and supporting documents have been prepared in accordance with, 15A NCAC 02T, 15A NCAC 02T .0300, Division policies and good engineering ractices. While no upfront engineering design documents are required for submittal, in accordance with I5A NCAC 02T .0305(b), design documents must be prepared prior to submittal of a fast track permit application to the Division. This would include plans, design calculations, and project specifications referenced in 15A NCAC 021' .0305 and the applicable minimum design criteria. These documents shall be available upon request by the Division. Projects that are deemed permitted (do not require a permit from the Division) are explained in GJ'A NCAA 02 F"0303. Projects not eligible for review via the Fast track process (must be submitted for full technical review): D Projects that require an environmental assessment in accordance with 15A NCAC IC .0100; %- Projects that do not meet any part of the minimum design criteria (MDC) document; > Projects that involve a variance from the requirements of 15A NCAC 2T; Pressure sewer systems utilizing septic tank -effluent pumps (STEPS) or simplex grinder pumps; STEP or simplex grinder pumps connecting to pressurized systems (e.g. force mains); Vacuum sewer systems. General— When submitting an application, please use the following instructions as a checklist in order to ensure all required items are submitted. Adherence to these instructions and checking the provided boxes will help produce a quicker review time and reduce the amount of requested additional information. Failure to submit all required items will necessitate additional processing and review time, and may result in return of the application. Unless otherwise noted, the Applicant shall submit one original and one copy of the application and supporting documentation. A. One Original and One Copy of Application and Supporting Documents ® Required unless otherwise noted B. Cover Letter (Required for All Application Packages): ® List all items included in the application package, as well as a brief description of the requested permitting action. %- Be specific as to the system type, number of homes served, flow allocation required, etc. D If necessary for clarity, include attachments to the application forth. C. Application Fee (All New and Major Modification Application Packages): ® Submit a check or money order in the amount of S490.00 dated within 90 days of application submittal. Payable to North Carolina Department of Environmental Quality (NCDEQ) D. Fast Track (Form: FTA 04-16) Application (Required for All Application Packages): ® Submit the completed and appropriately executed application. If necessary for clarity or due to space restrictions, attachments to the application may be made. ® If the Applicant Type in Item 1.2 is a corporation or company, provide documentation it is registered for business with the North Carolina Sec�1 Late. ❑ If the Applicant Type in Item 1.2 is a partnership or d/b/a, enclose a copy of the certificate filed with the Register of Deeds in the county of business. ® The Project Name in Item H. I shall be consistent with the project name on the flow acceptance letters, agreements, etc. ® The Professional Engineer's Certification on Page 5 of the application shall be signed, sealed and dated by a North Carolina licensed Professional En ineer. ® The Applicant's Certification on Page 5 of the application shall be signed in accordance with 15A NCAC 02T .01U6tbj. Per 15A NCAC 02T .0106(c), an alternate person may be designated as the signing official if a delegation letter is provided from a person who meets the criteria in 15A NCAC 02T .0106(b). INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page I of 3 E. Flow Tracking/Acceptance Form (Form: FTSE 04-I6) (If Applicable): ® Submit the completed and executed FTSE form from the owners of the downstream sewers and treatment facility. Multiple forms maybe required where the downstream sewer owner and wastewater treatment facility are different. Z The flow acceptance indicated in form FTSE must not expire prior to permit issuance and must be dated less than one year prior to the application date. Submittal of this application and form FTSE indicates that owner has adequate capacity and will not violate G.S_ 143- 215.67(a). -� Intergovernmental agreements or other contracts will not be accepted in lieu of a project -specific FTSE. F. Site Maps (All Application Packages): ® Submit an 8.5-inch x I I -inch color copy of a USGS Topographic Map of sufficient scale to identify the entire project area and closest surface waters, Location of the project (gravity sewer, pump stations & force main) Downstream connection points and permit number (if known) for the receiving sewer ® Include a street level map (aerial) showing general project area so that Division staff can easily locate it in the field. G. Existing Permit (All Modification Packages): ® Submit the most recently issued existing permit. ® Provide a list of any items within the permit the Applicant would like the Division to address during the permit modification (i.e., permit description, Flow allocation, treatment facility, etc.). H. Power Reliability Plan (Required if portable reliability option utilized for Pump Station): Per I SA NCAC 02T,0305th 1 ti, submit documentation of power reliability for pumping stations. This alternative is only available for average daily flows less than 15,000 gallons per day D It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant and is compatible with the station. The Division will accept a letter signed by the applicant (see 15A NCAC 02T .0106(b)) or proposed contractor, stating that "the portable power generation unit or portable, independently -powered pumping units, associated appurtenances and personnel are available for distribution and operation of this pump station." If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. (Required at time of certification) 1. Certificate of Public Convenience and Necessity (Ali Application Packages for Privately -Owned Public Utilities): pll? Per 13A NCAC 02T .01 I5 a l provide the Certificate of Public Convenience and Necessity from the North Carolina Utilities Commission demonstrating the Applicant is authorized to hold the utility franchise for the area to be served by the sewer extension, or ❑ Provide a letter from the North Carol:na Utilities Commission's Water and Sewer Division Public Staff stating an application for a franchise has been received and that the service area is contiguous to an existing franchised area or that franchise approval is expected. J. Operational Agreements (Applications from HOA/POA and Developers for lots to be sold): 1401 Home/Pro a Owners' Associations 0 Per 15A NCAC 02T .01 I Lc), submit the properly executed OEerational Agereement (FORM: HOAR. ❑ Per I5A NCAC 02T .01 f 5(c), submit a copy of the Articles of Incorporation, Declarations and By-laws. ❑ Developers of lots to be sold 0 Per 15A NCAC 02T .01 I5(b), submit the properly executed Operational Agreement FORM: DEVi. For more information, visit the Division's collection systems wehsile INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page 2 of 3 THE COMPLETED APPLICATION PACKAGE INCLDING ALL SUPPORTING MATERIALS, INFORMATION AND SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE: REGIONAL OFFICE ADDRESS COUNTIES SERVED Asheville Regional Office Water Quality Section 2090 US Highway 70 Swannanoa, North Carolina 28778 Avery, Buncombe, Burke, Caldwell, Cherokee, Clay, Graham, Haywood, Henderson, Jackson, (828) 296-4500 Macon, Madison, McDowell, Mitchell, Polk, (828) 299-7043 Fax Rutherford, Swain, Transylvania, Yancey Fayetteville Regional Office Water guality Section 225 Green Street Suite 714 Fayetteville, North Carolina 28301-5094 Anson, Bladen, Cumberland, Harnett, Hoke, Montgomery, Moore, Robeson, Richmond, (910) 433-3300 Sampson, Scotland (910) 486-0707 Fax Mooresville Re ional Office Water Quality Section 610 E. Center Avenue Alexander, Cabarrus, Catawba, Cleveland, Mooresville, North Carolina 28115 Gaston, Iredell, Lincoln, Mecklenburg, Rowan, (704) 663-1699 Stanly, Union (704) 663-6040 Fax Ralei h Re tonal Office Water quality Section 1628 Mail Service Center Raleigh, North Carolina 27699-1628 Chatham, Durham, Edgecombe, Franklin, (919) 791-4200 Granville, Halifax, Johnston, Lee, Nash, Northampton, Orange, Person, Vance, Wake, (919) 788-7159 Fax Warren, Wilson Washington Re tonal Office Water Quality Section 943 Washington Square Mall Beaufort, Bertie, Camden, Chowan, Craven, Washington, North Carolina 27889 Currituck, Dare, Gates, Greene, Hertford, Hyde, (252) 946-6481 Jones, Lenoir, Martin, Pamlico, Pasquotank, (252) 975-3716 Fax Perquimans, Pitt, Tyrrell, Washington, Wayne Wilmington Regional Office Water QualitySection 127 Cardinal Drive Extension Wilmington, North Carolina 28405 Brunswick, Carteret, Columbus, Duplin, New (910)796-7215 Hanover, Onslow, Pender (910) 350-2004 Fax Winston-Salem Regional Office Water Quality Section 450 W. Hanes Mill Road Suite 300 Alamance, Alleghany, Ashe, Caswell, Davidson, Davie, Forsyth, Guilford, Rockingham, Randolph, Winston-Salem, North Carolina 27105 Stokes, Surry, Watauga, Wilkes, Yadkin (336) 776-9800 INSTRUCTIONS FOR FORM: FTA 04-16 a SUPPORTING DOCUMENTATION Page 3 of 3 AA State of North Carolina Department of Environmental Quality Division of Water Resources fiNklon of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: Johnston County Project Name for which flow is being requested: In lesia Nueva Jerusalem More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow, I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Central Johnston County Regional WW Facility b. WWTP Facility Permit #: WQS00060, NCO030716 All flows are in MGD c. WWTP facility's permitted flow 9.5 d. Estimated obligated flow not yet tributary to the WWTP 1.34144 e. WWTP facility's actual avg. flow 5.9306 f. Total flow for this specific request 0.00054 g. Total actual and obligated flows to the facility 7.2720 h. Percent of permitted flow used 76.5 II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Average Daily Approx. Not Yet Total Current Statmn Firm Flow* * Current Avg, Tributary Flow Plus (Name or Capacity, * (Firm - po, Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** McGees 0.2592 0.1037 0.03063 0.00054 0.03117 0.07251 Landfill 1.9296 1.9296 0.6240 0.6497 1.2737 0.6559 * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pi) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): 319 Commerical Park FM Downstream Permit Number: WQ0017015 Page 1 of 6 III. Certification Statement: I Chandra C. Coats, P.E. certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow. Signing Oj icial Signature Date Page 2 of 6 February 15, 2021 Mr. Jason T_ Robinson, PE NCDEQ Raleigh Regional Office Water Quality Section 1628 Mail Service Center Raleigh. North Carolina 27699-1628 RE: Iglesia Nueva Jerusalen FTA Permit Modification - WQ0039143 Dear Jason. FROEDLINEENGME11111 NC Dept of Environmental Quality MAR - 4 2021 Raleigh Regional Office I hope this letter finds you well. Per our email and phone correspondence regarding the Iglesia Nueva Jerusalen Church Pump Station & Forcemain (WQ0039143), enclosed is a Fast -Track permit modification application and supporting documentation, As discussed, the original design of the system called for a duplex pump station, valve vault, gravity sewer extension and stand-by generator. As discussed, because this pumps station serves a single building and has a design flow less than 600 gpd, a simplex pump station is allowable with 24 hours of storage. It should be noted that the church has not lost power for more than a few hours in the recent 3 years. As such, only 24 hours of storage volume is required. The 1,500 gallon pump tank provides approximately 920 gallons of storage above the pump on, minimum water level, As such, the storage requirement is exceeded for this pump station_ Also per our correspondence, the originally permit called for a 4" gravity sewer extension. However, since this line is on private property and serves only a single building with less than 600 gpd, this is not considered a sewer main extension The location of the pump station and length of forcemain and connection have not changed from the original permitted plans_ I have included pump and control panel information in this package for your records, along with the required maps and documentation with the FTA application checklist. Thank you for your assistance with this FTA Permit Modification Application. If you need any further information or have any other questions, please feel free to contact me directly at (919) 779-6851 or email me at a .mccabe rlenc.com. Have a Blessed Day, a'J. McCabe, PE Red Line Engineering, PC 123 Raleigh Street Fuquay-Varina, North Carolina 27526 Office: (919) 779-6851 Mobile: (919) 606-4560 123 Raleigh Street ■ Fuquay-Varina, NC 27526 o Office: (919)779-6851 u www.rienc.com rfI rrrn � _ w r zno T � r M aol # v f ; oce f wj,j.IAMR l r-I ' - BRANCH p J- i c h r m AD _ a c +� o�1ti1 -�p RpBERSS - I Y (n1 � y' f I �artiL c �o i a o e W pb,8,3 HQ d`�bN]Nd NJV3d 'a -\ cn .Il � +V � - v tip o .i50 lireF z Robinson, Jason From: Gary McCabe <gary.mccabe@rlenc.com> Sent: Friday, October 30, 2020 5:16 PM To: Robinson, Jason Cc: Cashion, Ted Subject: [External] Re: Re: Iglesia Nueva Jerusalen External email. Do not click links or open attachments unless you verify. Fend all suspicious email a� arl attachment to 5 a rrt,F;oy Excellent. Thank you Jason. Have a great weekend! Have a Blessed Day, Gar .7. McCabe P.E. 123 Raleigh Street Fuquay-Varina, North Carolina 27526 Office: (919) 779-6851 Mobile: (919) 606-4560 On Fri, Oct 30, 2020 at 4:39 PM Robinson, Jason <jason.t.robinson c ncdcnr.gav> wrote: Thanks Gary, The pump station would need to meet the 15A NCAC 02T Rules (revised Sept 2018) and the Division's PS/FM Minimum Design Criteria: both found here: (link) If the pump station is only serving one building, and the design flow for the project is less than 600, then a simplex pump maybe used. And simplex pump doesn't require a standby generator. But 24 hour storage, or storage for the longest power outage in the last three years, whichever is greater (I think a 1,500 gallon pump tank should be able to handle that). In order to utilize a 2" forcemain, the pump will have to be a grinder pump. From: Gary McCabe [mailto: a .mccabe rlenc.com] Sent: Thursday, October 29, 2020 4:29 PM To: Robinson, Jason <'a� son.t.robinson@ncdenr.sov> Cc: Cashion, Ted <ted.cashion ncdenr. ov> Subject: [External] Re: lglesia Nueva Jerusalen r,v l:xterna} eriia}I, Do not click links or open attachments udiess you verify. Send all suspicious em as an attachme nt o "1 r-ems a' nc,�nv Jason, Sorry for the delay, Since I didn't originally design or permit the project, I wanted to get your question answered from the GC rather than venture a guess. NO the new 4" line only services the new sanctuary building. The existing building does NOT tie onto the new system. The existing building already has an onsite septic system that will remain. It is my understanding that, eventually, the existing building with vinyl siding will be demolished and removed. Hope this helps. Thanks for looking into this for me. Have a Blessed Day, Gary J. McCabe, P.E. 123 Raleigh Street 3 4 your requests by phone or email. We appreciate your patience as we continue to serve the public during this challenging time. From: Gary McCabe [mailto:Qary.mccabe@rlenc.comi Sent: Monday, October 19, 2020 8:31 AM To: Robinson, Jason <jason.t.robinson@ncdenrsov> Subject: [External] Iglesia Nueva Jerusalen nolr External email. Do not click link, or open attachments unless yd.0 verify. Send all suspicious entail as anattachment to rfl nc. u Jason, I hope you are well sir. I am helping out a friend on this project. They are the septic system/pump station installer on the Iglesia Nueva Jerusalen Church. The permit docs and plans are attached. They were designed by Larry Anderson, PE back in 2016. Mr. Anderson appears to have designed and permitted a duplex municipal grade pump station, which is fine. However, it is a bit out of reach for the church cost -wise. After looking at the plans and calcs, it appears that the church only has a design flow of 540 gpd, which is below the typical threshold for duplex pump stations and many of the selected pump station features. The church needs to make some value -engineering changes, such as the following: 1. Install 1,500 gallon pump tank instead of wet well 2. Install single Zoeller or Meyers pump instead of duplex ABS Piranha pumps 3. Eliminate backup generator 4. Install control panel for the selected pump instead of panel specified 5. Substitute 2" sch 80 PVC piping in the wet well instead of DIP (2" DIP doesn't exist) It is my understanding that the church has contacted Mr. Anderson and he is not interested in participating in the value -engineering or redesign of the pump station and forcemain. As such, I have been asked to help out. Given the low flow, the requested Robinson, Jason From: Gary McCabe <gary.mccabe@rlenc.com> Sent: Friday, October 30, 2020 5:16 PM To: Robinson, Jason Cc: Cashion, Ted Subject: [External] Re: Re: Iglesia Nueva Jerusalen External email. Do not -click links or open attachments unless you verify. Send allsu"spicious email as.an attachment to Excellent. Thank you Jason. Have a great weekend] Have a Blessed Day, u_ary i, mcca P.E. 123 Raleigh Street Fuquay-Varina, North Carolina 27S26 Office: (919) 779-6851. Mobile: (919) 606-4560 On Fri, Oct 30, 2020 at 4:39 PM Robinson, Jason <jason.t.robinson a ncdenneov> wrote: Thanks Gary, The pump station would need to meet the 15A NCAC 02T Rules (revised Sept 2018) and the Division's PS/FM Minimum Design Criteria: both found here: (link) If the pump station is only serving one building, and the design flow for the project is less than 600, then a simplex pump may be used. And simplex pump doesn't require a standby generator. But 24 hour storage, or storage for the longest power outage in the last three years, whichever is greater (I think a 1,500 gallon pump tank should be able to handle that). In order to utilize a 2" forcemain, the pump will have to be a grinder pump. t From: Gary McCabe [mailto:gary.mccabe@rlenc.coml Sent: Thursday, October 29, 2020 4:29 PM To: Robinson, Jason <iason.t.robinson@ncdenr.gov> Cc: Cashion, Ted <ted.cashion@ncdenr.gov> Subject: [External] Re: Iglesia Nueva Jerusalen External. email. Do nW click links or open attachments unless you verify. Send all suspicious email as an attachment to Jason, Sorry for the delay, Since I didn't originally design or permit the project, I wanted to get your question answered from the GC rather than venture a guess. NO the new 4" line only services the new sanctuary building. The existing building does NOT tie onto the new system. The existing building already has an onsite septic system that will remain. It is my understanding that, eventually, the existing building with vinyl siding will be demolished and removed. Hope this helps. Thanks for looking into this for me. Have a Blessed Day, Gary J. McCabe, P.E. 123 Raleigh Street your requests by phone or email. We appreciate your patience as we continue to serve the public during this challenging time. From: Gary McCabe [mailto: a .mccabe rlenc.com] Sent: Monday, October 19, 2020 8:31 AM To: Robinson, Jason <iason.t.robinson@ncdenr.sov> Subject: [External] Iglesia Nueva Jerusalen txternal emaii. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to FL12 0A-5Parn2nya_ Jason, I hope you are well sir. I am helping out a friend on this project. They are the septic system/pump station installer on the Iglesia Nueva Jerusalem Church. The permit docs and plans are attached. They were designed by Larry Anderson, PE back in 2016. Mr. Anderson appears to have designed and permitted a duplex municipal grade pump station, which is fine. However, it is a bit out of reach for the church cost -wise. After looking at the plans and calcs, it appears that the church only has a design flow of 540 gpd, which is below the typical threshold for duplex pump stations and many of the selected pump station features. The church needs to make some value -engineering changes, such as the following: 1. Install 1,500 gallon pump tank instead of wet well 2. Install single Zoeller or Meyers pump instead of duplex ABS Piranha pumps 3. Eliminate backup generator 4. Install control panel for the selected pump instead of panel specified 5. Substitute 2" sch 80 PVC piping in the wet well instead of DIP (2" DIP doesn't exist) It is my understanding that the church has contacted Mr. Anderson and he is not interested in participating in the value -engineering or redesign of the pump station and forcemain. As such, I have been asked to help out. Given the low flow, the requested 5