Loading...
HomeMy WebLinkAbout20210404 Ver 1_Deep River Revised Raparian Buffer Impacts_20210412 Wanucha, Dave From:Moore, Della R Sent:Wednesday, April 14, 2021 9:43 AM To:Wanucha, Dave; Parker, Jerry A Subject:Re: Bridge 67_401 permit application Attachments:Deep River Revised Raparian Buffer Impacts.pdf Good Morning Dave, The riparian buffer impacts for Deep River summary sheet have been revised and is attached. As for the Critical Area parameters from West Fork to Deep River, 17(110) details include: *Critical Supply Watershed Index No. WS-IV:* 17-3-(1.5) 15 A NCAC 2B .0248 Randleman Lake This project is situated within a CA. Please let me know if you need anything else. Thanks, Della Moore NCDOT-Division 7 DEO's Environmental Assistant Engineer 1101 East Wendover Ave, Suite 200 Greensboro, NC 27405 336-334-3515P | 443-983-1580 C From: Wanucha, Dave <dave.wanucha@ncdenr.gov> Sent: Tuesday, April 13, 2021 8:44 AM To: Moore, Della R <drmoore2@ncdot.gov>; Parker, Jerry A <japarker3@ncdot.gov> Subject: Bridge 67_401 permit application Della and Jerry, Please confirm that the proposed project is or is not located within the critical area (CA) of a water supply raw water intake. It does not appear that it does, but the PCN provides information stating that West Fork Deep River (at the proposed project location) does reside with the CA. Please confirm so that we can prepare a 401 Certification. Thanks. Dave W. Division of Water Resources 401 & Buffer Transportation Permitting NC Department of Environmental Quality 336-776-9703 office 336-403-5655 mobile Dave.Wanucha@ncdenr.gov 1 NC DEQ Winston Salem Regional Office 450 West Hanes Mill Road, Suite 300 Winston Salem, NC 27106 Based on the current guidance to minimize the spread of COVID-19, the Department of Environmental Quality has adjusted operations to protect the health and safety of the staff and public. Many employees are working remotely or are on staggered shifts. To accommodate these staffing changes, all DEQ office locations are limiting public access to appointments only. Please check with the appropriate staff before visiting our offices, as we may be able to handle your requests by phone or email. We appreciate your patience as we continue to serve the public during this challenging time. Email correspondence to and from this sender is subject to the N.C. Public Records Law and may be disclosed to third parties. 2 I RIPARIAN BUFFER IMPACTS SUMMARY IMPACTS BUFFER Site Station Structure TYPE ALLOWABLE MITGABLE REPLACEMENT No. (From/To) Size/Type ROAD BRIDGE PARALLEL ZONE 1 ZONE 2 TOTAL ZONE 1 ZONE 2 TOTAL ZONE 1 ZONE 2 CROSSING IMPACT (ft) (ft2) (ft2) (ft) (ft2) (ft2) (ftZ) (ft2) 1 -L- 14+58 TO 16+08 33" BOX BEAM, 1 SPAN @ 85' X 2693 1361 4054 X 3934 1824 5758 X 135 135 X ' X 6207 6783 12990 TOTALS*: 12834 10103 22937 0 0 0 0 0 NOTES; NC DEPARTMENT OF TRANSPORTATION DM5ION OF HIGHWAYS JANUARY 27, 2021 GUILFORD COUNTY 17BP.7.R.127 n.dwla,erm SHEET 6 OF 7 i ' 7 '