Loading...
HomeMy WebLinkAboutWQ0011323_Regional Office Historical File Pre 2018 (2)A Michael F. Easley, Governor William G. Ross Jr., Secretary North Carona Departrnent of Environment and Natural Resources Alan W. Klimek, P,E., Director Division of Water Quality Coleen H. Sullins, Deputy Director Division of Water Quality September 25, 2003 Mr, Paul Campbell, Director of Engineering City of Concord P.O. Box 308 Concord, North Caro ina 28206 Subject: Permit No, WQ0011323 Modification City of Concord Cochran Farm Subdivision- Phase 2A Wastewater Collection System Extension Cabarrus County Dear Mr, Campbell In accordance with your application received on September 19, 2003, we are forwarding herewith Permit No. WQ0011323, dated September 25, 2003, to the City of Concord for the construction and operation of the subject wastewater collection system extension, This permit shall be effective from the date of issuance until rescinded, shall void Permit No. WQ0011323 issued August 25, 1995, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. The modification includes the abandonrnent and removal of the previously permitted 84-gpm pump station with duplex pumps and 2,810 linear feet of 4-inch force main, Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Also note Permit Condition 12 regarding the abandonment of the pump station and force main. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1)15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 919 N. Main Street, Mooresville, NC 28115 Internet http://h2o enr state,ncwsi Telephone (704) 663-1699 Fax (704) 663-6040 DENR Customer Service Center Telephone 1 877 623-6748 Mr. Paul Campbell Page 2 September 25, 2003 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Concord for the continued operation of approximately 3,234 linear feet of 8-inch gravity sewer to serve 134 three -bedroom residences as part of the Cochran Farm Subdivision -Phase 2A project, and the discharge of 48,240 gallons per day of collected domestic wastewater into the Water and Sewer Authority of Cabarrus County's (WSACC) Rocky River WWTP (NPDES No, NC0036269) existing sewerage system, pursuant to the application received September 19, 2003 and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable, the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall become voidable unless the agreement between the City of Concord and WSACC for the collection and final treatment of wastewater is in full force and effect. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 1508 of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Sonja Williams at (704) 663-1699. Sincerely, for Alan Wm Klimek, P.E. cc: Cabarrus County Health Department Mooresville Regional Office, Water Quality Section (WV11TF Permit No. NC0036269) Paul Campbell, City of Concord Water Quality Central Files NDPU Files NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0240; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times, The Permittee shall maintain compliance with an individual systern-wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. if an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H 0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200 b. A map of the sewer system shall be developed prior to January 1, 2004 and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year, g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C, 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved, 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6, Upon completion of construction and prior to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit, 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of czimpletion once the entire project has been completed. A copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings," and one copy of the supporting design calculations to the Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617, 7. A copy of the construction record drawings shall be maintained on file by the Perrnittee for the life of the wastewater collection facilities. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11, Noncompliance Notification: The Permittee shall report by telephone to the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Persons reporting such occurrences by telephone shall also file a written report in letter form within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur, 12. The pump station with duplex pumps and force main shall be properly abandoned as to not cause negative public health, safety, and environmental issues. Permit issued this the 25th day of September, 2003, NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Ktini&< P,E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0011323 Fast Track Engineering Certfication Permit No, WQ0011323 Modification September 25, 2003 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater ion system extension supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are tired for an ch n es esul liance with this permit, regulations or minimum design criteria. cone This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICAllON Partial El Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (EI periodically, LI weekly, EI full time) the construction of the Cochran Farm Subdivision- Phase 2A, Cabarrus County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable: the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials, North Carolina Professional Engineers seal, signature, and date. SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE 919 N. MAIN STREET MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineers Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. FAT -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Application Number: (to be completed by DWQ 1. Owner: la. Ciq_of Concord Full Legal Name (company, municipality, HOA, utility, etc.) • ib, Paul D. Campbell P.E, Director of Engineering 0 323 Signing Official Name and Title (Please review 15A NCAC 2H ,0206(b) for authorized signing officials!) The legal entity who will own this system is. 0 Individual 0 Federal Municipality 0 State/County 0 Private Partnership El Corporation 0 Other (specify id, 850 Warren C Coleman Blvd Street Address North Carolina State 0 a_ 704-920-5425 11. 704-786-4521 Telephone Facsimile 2, Project (Facility) Information: 2a, Cochran Farms Subdivision Phase 2A Brief Project Name (permit will refer to this name) 3Contact Person: le. Concord City 1g, 26026 Zip Code lj campbell E-mail 2b. Cabarrus 3a. Sherri V. Moore, PermittingServi Mane er Name and Affiliation of Someone Who Can Answer concoranc.us County Where Project is Lo uestions About this Application 3b. 704-920-5415 3c, moores©ciconcord.ne.us Phone Number E-mail 1 Project is 0 New Modification (of an existing permit) If Modification, Permit No.: WQ0011323 For modifications, attach a separate sheet clearly explaining the reason for the modification (Le. adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information in 13(7) and B(10-11) that has already been included in the original permit. 2 Owner is Public (skip to Item B(3)) 0 Private (go to Item 2(a)) 2a. If private, appticant will be: 2b. If sold, facilities owned by a (must choose one) D Retaining Ownership (i.e. store, church, single office, etc) or Z 0 Leasing units (lots, townhomes, etc. - skip to Item 8(3)) 0 El Selling units (lots, townhomes, etc. - go to item B(2b)) O Public Utility (instruction 111) O Homeowner Assoc,/Developer (Instruction IV) I , < 3, Water & Sewer Authority of CabarrusCounty, WSACC Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 4b NC00362669 0 Name of WWTF 4a, RocRy. River WWTP Ll- VVVVTF Permit No, Z 5a, City of Concord 15b. 8-inch !.5c„ WQ0022595 - Yates Mill ,Subdivision Owner of Downstream Sewer Receiving Sewer Size ! Permit Number of Downstream Sewer (if known) 6 The origin of this wastewater is (check all that apply) Residential Subdivision 0 Car Wash W 0 Apartments/Condominiums 0 Institution 100 % Domestic/Commercial 0 Mobile Home Park 0 Hospital % Industrial 0 School D Church 0 Restaurant 0 Nursing Home % Other (specify): 0 Office El Other (specify): 7. Volume of wastewater to be permitted in th s project. 0 gallons per day 8. If the permitted flow is zero, indicate why: 0 Interceptor Line - Flow will be permitted is subsequent permits that connect to this line Flow has already been allocated in Permit No. VVO0Q11323 - Cochran Farms Subdivision, Phase 2A 0 Rehabilitation or replacement of existing sewer with no new flow expected FA&' -TRACK APPLICATION for GRAVITY SEWERS,1'UMP STATIONS, .AN:D FORCE MAINS PAGE 4 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Itern B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H M219(I)(1-2) must be approved prior to submittal of this application, Submit a separate request to the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H ,0219(I)(3). The Cochran Farm Subdivision Phase 2-A 's 84 GPM pump station with duplex pumps and the 2810 linear feet of 4-inch force main shall be abandoned and removed from the pump station site, Flow was allocated under the Cochran Farm Subdivision Phase 2A permit WQ0011323. The Yates Mill Subdivision, permit number WQ0022595, will extend the gravity sanitary sewer system to accommodate 48,240 gpd from the Cochran Farm Subdivision Phase 2-A. Attached is a copy of the original permit with the supporting documentation. 10 Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) z ENTER TOTAL LINE LENGTH IN MILES 0 Length (feet) 11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Gravity or Force Main (use the pull down menu) Location ID Power Reliability Option (self chosen - as shown on Design Flow Operational Point (1- dual line feed; 2- permanent generator w1ATS; 3- plans for cross-reference) (MGD) GPM TDH portable generator vdtelemetry 4-wet well storage) 12, Does the sewer system comply with the Minimum Design C ; eria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? Yes 0 No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATIONS, 3. Have the following pemiitslcertifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? 0 Yes 0 No N/A Sedimentation and Erosion Control Plan? Q Yes 0 No 0 N/A Stormwater? 0 Yes 0 No N/A FAST -TRACK APPI ICATiON for GRAVITY SEWERS, PI` MP STATIONS, AND FORCE fl'IAINS PAGE 5 Use the Division"s guidance document entitled" "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as' necessary), This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: A Stream Classification is not needed because all parts of the project ar waterbody; AND, A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map (self chosen - as shown on map for cross-reference) feet away from any down slope Waterbody Stream Waterloo Waterbody County River Basin Index Classt Name of Submit the II,S" x 11" COLOR topographic map as required in Instruction Vi s of whether a classification is provided! Applicant's Cefflficlian. 1, Paul D. Campbell. PE, this pp at n bran Farms Subdivision, Phase 2A has been reviewed by me and is accurate thd complete fo the best of my knowledge, I understand that ii all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as Incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215, 6E3, any person who knowingly makes any false statement, representation, or certifi in any application shall be guilty of a Class 2 misdemeanor which .may include a fine not to exceed $10, t 7 allies up to $25,r violation, Signi'g Cffitai Signe Profewiona! Engineer's Certification; i attest that this application for hran Farms Su di ision,Phase,2A has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, end all other supporting documentation to the best of my knowledge, I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer lv*nimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations end Force Mains adopted June x 1, 2€00 and the watershed classification in accordance with Division guidance, Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note.: In accordance with NC General Statutes 143-215,6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10, 000 as well as civil penalties up to $25, 000 per violation. 2a. Paul D. Campbell - Department Engineer Professional Engineer Name 2b. City of Concord Engineering Firm 2c, 850 Warren C. Coleman Blvd, _ Address 2d, Concord 2e. NC City State 2g. 704-920-5401 2h, 704-786-4521 2i. pb Telephone Facsimile 2f, 28026 Zip donc.us Rev-ised Non -Discharge Permit Applications. gcment's Water Quality Section has revised the To: Gov: rnor y, Jr_, Seer ary State of North Carolina Department of Environment, Heslth, nd Natural Resources Division of Environmental Management 512 North Salisbury Street • Raleigh, North Carolina 2762 -0535 Gc,rgc T. Evtrcu, Phi. Diirtar adurn 1lcgatcnd Municipalit From: Steve W. Tedder, Chi Water Quality Section Subj DeIegat Municipalities C eel st e _._. The Division of Ertvi trotrra_ GravSewer Non -Discharge Ap ity � ge Permit Application Form. The form now incorporates the basic information that the Division feels is necessary in order for the delegated municipalities to perform a review on a gravity sewer project for the Division; therefore, the Division will no longer require that the "Delegated Municipalities Gravity Sewer Design Checklist" be completed and submitted. We do, however, require that the delegated municipality perform the same type of review as always required and complete the bottom portion of this page and attach it as the last page of all gravity sewer applications that being submitted as a delegated municipalities project If you have any qucsdons on this utter, please contact Mr. Randy Jones at 919/733-5083,. DELEGATED MTJNTCLPALITY GRAVITY SEWER CERTIFICATION (THIS FORM MAYBE PHOTOCOPIED FOR USE AS AS ORIGINAL) May 1,1991 ity of Concord Delegated MTulnicipality Reviewer's Certification: 1, Paul. D. Camp ell , ettest that the subject plans and specifications have been reviewed tinder rny super ision and that those plans and specifications cations c consistent with the iaformadon that has been specified on the Non -Discharge Application and the Division of Environmental Management's minimum design ^u c; n nts for ,gravity s wcr proje=ts• Delegated Municipality Reviewer's NC Professional Engineer's Reg st-a.don No_: Seal and Signatu t (pecify date): FORM: h'MCS 4191 PAGE 1 OF I 9 TopoZone - The Web's Topographic Map Page 1 of 1 0.3 0.6 0.9 1.2 1.5 km r 0 0.2 0.4 0:6 0.8 1 mi Map center is UTM 17 532720E 3910983N (NAD27) Harrisburg quadrangle Projection is UTM Zone 17 NAD83 Datum MN= -- r . 385 GN.=-O.206 httpa/www.topozone.coni1print.aspi-17&n�3910983.21613851&e-532'719.969083874&s=5( 9/15/03 TopoZone - The Web's Topographic Map Page 1 of 1 Get a Map Pece,.name.,searcih pec rTaal„de_grees ©,egJ [nLs@c Urrn c9prds Download Map IgP.:4,.Ea ctU ry_lgg i rl. At�q,r�,t Tq,poPaetc�ry Specificat rs How to... Put,topp maps©n Y.©.ur Web.sl't�e Get.._d.igta l_d.ate l��ak_te.._us What's New? Getwdhe T°ear�;P'i�es Press releases �vaw � Tgpq�ane Help T_gpo, maa_syanbQl,s FAQ Suppprt P_rvacy._P.©Sicy. Abp�.u,s USGS Map Detail Please use this information if you're ordering a printed USGS topographic map from a dealer. Different dealers may prefer to use either the ISBN $ Number or the Order ID to specify a map, so keep all the information with you when placing an order. To find a USGS map dealer, consult the USGS.Ms lit° Name State(s) Map Type Scale Currentness Year ISBN Number USGS Order ID USGS Entity Id HARRISBURG NC Topographic (feet) 1:24000 1993 0607623276 TNC0316 M PTN C0316 PP01 Area Covered 7.5 minute Projection Lambert Conformal Conic. Northwest corner Northeast corner Southwest corner Southeast corner 35.37500N,-80.75000W 35.37500N,-80.62500W 35.25000N,-80.00000W 35.25000N,-80.62500W The TopoZone is produced by Maps a la carte, Inc, - 1999•2003 Maps a la carte, Inc. - All rights reserved, Use of this site is go Cvndrt ens„and Terrnns ,qf Use„ We care about your privacy - please consult our PriyacyStatement for details. http://www.tapazane.camlm1\1C0 316PPO1 9/15/03 7.5 MINUTE SERIES (TOPOGRAPHIC) .44° 51 510000 FFET 533 B0°i37°30 " 4 FF T MELE FEET Primary hughway, hard surface. Secondary highway, hard surface a QUADRANGLE LOCAPCN Revisions shown in purple compiled i'n cooperation with North Carolina Department of Environment, Health and Natural Resources from imagery dated 1993 and other sources 'T Map edited 1996 ROAD CLASSIFhCATR)N hard or mproved surf Trproved road mm.. Route U. S. Route ; `State Route HARRISBURG, NC 35O8O-C6-TF-024 1993 DMA 4854 S SW -SERIES V842 information shown in purple may not meet USGS content 09124/03 Perim umber 00i Program Category Non -discharge Permit Type vtt Sewer Extension, Pump Stations, Pressure Sewer Extensions Primary Reviewer sonja,williams 323 Permitted Flow 0 Track Facility Facility Name Concord City -Cochran FA Location Address Owner Owner Name City of Concord Da Permit Tracking i Status Protect Type In review Major modification Version Permit Classification Individual Permit Contact Affiliation George wder PO Box 308 Concord J 28026 Ong is ti App Received 08/25/9 09/19/03 Regulated AcAct Subdivision Wastewater collection Wastewater treatment and disticasal utfall MaioriMinor' Minor Region Mooresville County Cabarrus Facility Contact Affiliation Owner Type Government - Municipal Owner Affiliation Paul PO Box 308 Concord Scheduled Initiated Issuance dv Name Campbell NC 28026 Effec Reguested/Received Events Ad unto atiran requested Additional Information received Expiration Stream Index Plumber Current Class Sub asin ttt /1,1 s'ISJYYtekititto Vst crry COLIC(111D it() (ttlf titt(St Hts"ttittt,tti FIII Els\1 1tit1:1.11AI tIttft AlStItY WACIK3vtv tivytys tiATIOStAL ASYYttivt tun ttt.trtt vitt tsto VON) Af THY 60 DAYS 1-3\ FOUR HUNDRED DOLL ARS & ZERO CENTS IHr LINDF H NC DEPT OF ENVIRONMENT &t.NA TORAL RES 919 r4 MAI VV sT PIDORESV ILIEE, NC 281.15-'1 617 AMOLIN V (;"1:L1C 2 6 019 7 2601 7 DA1E 09/12/03 111:4303 SOT RiOnt Cab. ,"11'11.1","v1,","Ci hy 1hI osai (Yost:tutus:HI fStStstt ssyt ",it r :sadist Act tV".1 tot' ot, 01 ,, t' s 260197e I:053LO II: 20 V1900 21.8660 MS WW1 S SYS'S NS mate of North Carolina Department of Environment, Health and Natural Resources Division of Environmental Management James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director August 25, 1995 Mr. George T. Lowder City of Concord Post Office Box 308 Concord, North Carolina 28026-0308 Subject: Permit No. WQ0011323 City of Concord Cochran Farrn. Subd , Phase Sewer Extension Cabarrus County Dear Mr, Lowder: In accordance with your application received July 17, 1995, we are forwarding herewith Permit No. WQ0011323 dated August 25, 1995, to the City of Concord for the construction and operation of the subject wastewater collection extension. This permit shalt. be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, P.O. Drawer 27447, Raleigh, NC 27611-7447. Unless such demands are made this permit shall be final and binding. One set of approved plans and specifications is being forwarded to you. If you need additional information concerning this matter, please contact Liz Kovasckitz at (919) 733-5083 ext. 516 Cabarrus County Health Department Mooresville Regional Office, Water Quality Section W. Earl Cochran & Son, Inc. Sincerely, A. 'Prestozi, Howard, Jr:; RE, P.©, Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-5033 FAX 919-733-9919 An Equal Opportunity Affirmative Action Employer 50% recycled' 10% post -consumer paper NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT, HEALTH AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION PERMTT in accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO City of Concord Cabarrus County FOR 1HF construction and operation of approximately 3,234 linear feet of 8 inch gravity sewer, a 84 GPM pump station with duplex pumps, high water alarms, portable generator, and approximately 2,810 linear feet of 4 inch force main, to serve 134 three bedroom homes in Cochran Farm Subdivision, Phase 2-A, and the discharge of 48,240 GPD of collected domestic wastewater into the City of Concord's existing sewerage system, pursuant to the application received July 17, 1995, and in conformity with the project plan,. specifications, and other supporting data subsequently filed and approved by the Department of Environment, Health and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data, This permit is effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The facilities must be properly maintained and operated at all times. 4. The sewage and wastewater collected by this system shall be treated in the Water & Sewer Authority of Cabarrus County's Rocky River Regional Wastewater Treatment Facility prior to being discharged into the receiving stream. This permit is not .transferable. In the event there is a desire for the facilities to change ownership, - or there is a name change of the Permittee,a formal permit request must be submitted to the Division of Environmental Management accompanied by an application fee, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be, approved. Construction of the sewers, pump station(s) and force main shall be scheduled so as not to interrupt service by theexisting utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting materials. Mail the Certification to the Water Quality Permits and Engineering Unit,P.O. Box29535, Raleigh, NC 27626-.0535. 8. A copy of the approved plans and specifications shall be maintained on file by the Permittee for a minimum of five years from the date of the completion of construction. 9. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to an enforcement action by the Division of Environmental Management, in accordance with North Carolina General Statute 143-215.6(a) to 1.43-215,6(c). 10. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. 11. The Permittee shall provide for the pump station and force main the following items: a. Pump on/off elevations located so that 2-8 pumping cycles may be achieved per hour in the pump station, b. An air relief valve located at all high points along the force main, c. A screened vent for the wet well, d. Fillets located in the wet well at the intersection of the flooring and sidewalls, e. Three feet of cover minimum) over the force main or the use of ferrous material where three feet cannot be maintained, f. Sufficient devices which. will protect the pump station from vandals, and g. Flood protection if the pump station is located below the 100-year :flood elevation. 12. In the event that the facilities fail to 'performsatisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement wastewater collection facilities. 13. NONCOMPLIANCE NOTIFICATION: The Permittee shall report by telephone to the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electricalfailures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Persons reporting such occurrences by telephone shall also file a written report in letter form within 15 days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. 2 i. N' August 25, 1995 EN I _ , as a duly registered lressianl Engineer in the State o North Carol' having been authorized to observe (periodically, weekly, ull : e) the construction n of the project, Project i ar kc-atio t for the Permittee hereby state that, to the best f my abilities.., due care and diligence was used in rye observation of the construction such that the coast cti n was observed to be built within substantial compliance and intent of this permit, the approved plans and specifications, and other supper -tin' materials. Signature Date Registration No. WATER & SEWER AU i HQrRfTY OF CABARRUS CO, June 29. 1995 Mr. G. Tim Lowder City of Concord P. O. Box 308 Concord. North Carolina 2.8026-030 Subject: Cochran Farm Subdivision, Phase 2-A City of Concord Dear Mr, Lowder: ti Please be advised, the Water and Sewer Authority of_Cabarrus'County has the available capacity at the Rocky River Regional Wastewater Treatment Plant to serve, and treat the domestic wastewater for the proposed sanitary sewer services to the Cochran Farm Subdivision, Phase 2-A, for a flow of 4,8,240 gpd. Please provide a copy of the details of the proposed connection including specifications. WSACC will provide separate approval of the connection upon receiving the requested information. Please notify to the interceptor so :ark Lomax at 704-788-4164 at .least 48 hours before the tie-in is made or a member of his staff can be present for the connection. Sincerely, hn. C. Murdock, T[I Executive Director J'CM:bmp cc: Mark A. Lomax 2b^Davitsan ; P.O, Box 26 w on'cord NC Permit No. WQ0011.323 ENGINEER'S CERTIFICATION I, Hugh Allen Scott, Jr., P.E. as a duly registe Carolina, having been authorized to observe of the project, Cochran Farm Subdivision Project Name sional Engineer in the State of North eekly, full time) the construction Cabarrus Co. for the Location permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance and intent of this permit, the approved plans and specifications, and other supporting materials. S ignatur Date Registration No. 71 (seal) Cornunents:. Sht. 8 of 11 - Line "A" extended 78 ft. to Sta. 7+33.86 and ?vEH # 2A added at end o 18 ft. (one joint of pipe) added before drop on PMIi # 2.. - 44.22 lin_ ft. of 8-inch DIP added between Sta. 0+91 and 1+35,22 on Lin - Line "C" dead end ME set at the end of this line at Sta. 3+81.06. ine. SEAL 18717 ;fNE. oN SC