HomeMy WebLinkAboutWI0800095_GEO THERMAL_20021024MEMORANDUM DIVISION OF WATER QUALITY GROUNDWATER SECTION October 24, 2002 To: Charles Stehrnan, Ph. D., LG., Regional Groundwater Supervisor Groundwater Section Wilmington Regional Office From: Mark Pritzl f'l~-Mark.Pritzl@ ncmail.net Hydrogeological Technician II UIC Program Groundwater Section Raleigh Central Office Re: Receipt of Notification for a Closed-Loop Geothermal Water-Only Injection Well System (type SQW injection well.) Notification to construct and operate a well for a closed-loop geothermal heat pump system has been filed by Charles Kay in Jacksonville, North Carolina and a copy of the Notification is enclosed for your files. The geothermal system is located at Excell Body Works, 221 Brynn Marr Road, Jacksonville NC. This injection well system is deemed permitted by rule (NCAC Tl5A: 2C.21 l(u)2) and no regulatory action is necessary. If you have any questions, please contact me at (919) 715-6166. cc: CO-UIC Files Enclosures 10/23/2002 16:43 3531060 PAGE 01 EMM:C ontrol -.0 Healing & Cooling Co., Inc Since 1980 102 Middle Street - Jacksonvilleg HC 28546 Phone (910) 353-9040 Fax (910) 353-4060 7im Alc--- V)E�Af j9,- ►� 14#41k A�� �� pmm 3 ftm 911.- ?�- e Dow E b z-3 --o x.— © uremd UIkw 1lvvWw 0 PIsa" Gvni nwd ❑ rkr Reply O Pl0000 Recycle ---`- �--��-._.......... ....... ...------------------ ---- ._................----------- .......... ...: :_.- --- Z -- ..... ..... ........ -4-0 --- -------- -- ------------------ ..._. ----.------ -...... --------------------------------------------- ......._..._........_._------------ �......�- . --------------- --------------------------------.----.--------------.----------..._....._. :�I.- .---........... JACKSO "f tv I I , PUMPKIN No"THSIDE CONMO ET TR.VFD 16 fr ACRE DNSiAN ItVATTW'�;' 4f S �ARWCAMT A ROL SWIP tu Acm A *000 \ZAT PUMPKIN OA C t. 'Jq CTR"4vr0?' V4F 't PC �w F04"ps le ' t II F0*`Kt AD C3 00 1 . IN ott V LLArtf, "nrpE�,� G#'q Orr c IVNE HIL4Lj, vpd-L,- UN T sop OLfFr r"r LN 41'X CLkj I IkFGAL AL -VA NWOODS 911 p x tt V ' 8546 44 SHERWM 8 N 4 FOREST COUNTRY COLLEGE COUNtRY,.. ;�' CLUB . CLUB VfARX TAL CAROL I ACRES:, %, ESTS. MAIUNITY 1 1 COLLUE J&CKSONVILL VARV \i Apr 'p, COUNTAV CLU a HITE OAK C TRY 1 0LTH s =!CL*s!Fm CcWHITS r E a* cr fo MOL sp. DCpA 5 us CT 4[ ROM i fa� 41 S�c 0�� ,h f F T I Mir Iri SHOW. A6 N A AGONA Nx- X17 ELL FORK t W HOMES ANAQM sm L* , 4CLYDE N w i\Vk ASHLE n"', MCA f6 54 24 tit 'V Y. 4 Hot mH --,TKORN BR n mo L 1, 6 Ito nR p 4WERS CK DOWNS Ft I 1-34ADO A c 41k vAm C -TA A E $Ai FAN s Lf' A. si'sr� 5ysr4r" cr N- 044 m M ao� LO 11 32+ So n y- g- Nco s Hip Sti o x a �- o x o� v 0 0 � � o s or A- S 2. 3 4' +t-i.. � -� � - 3: '. .• Syr. •.''�ti- c �yG. � - v�iRT� Michael F. Easley, Governor 0 RAG William G. Ross Jr., Secretary North Carolina, artment of Environment and Natural Resources r Alan W. Klimek, P.E. Director Division of Water Quality p � October 23, 2002 Charles Kay 221 Brynn Marr Road Jacksonville, NC 28546 Dear Mr. Kay: In accordance with your notification received on October 22, 2002; the Groundwater Section acknowledges your intent to construct closed-loozi geothermal water -only injection well system for the operation of ground -source heat pump. This system as described in your notification will not require an injection well permit and is deemed permitted by rude (North Carolina Administrative Code Title 15A: 2C.021 l(u)2). The Underground Injection Control (UIC) Group has added your site to our inventory. If you modify your system, please contact the Groundwater Section to verify compliance. Thank you for submitting this notification. If you have any questions regarding geothermal heat pump wells please feel free to contact me at (919) 715-6166 or Evan Kane at (919) 715-6165. cc: CO-UIC Files WIRQ-UIC Files VA tYnrN-R Customer Service 1 800 623-7746 Mark Pritzl Hydrogeological Technician U1C Program Division of Water Quality ! Groundwater Section 1636 Mail Service Center Raleigh, NC 27699-1636 Phone: (919)733-3221 Fax: (919)715-0588 Internet: http:1/gw.ehnr.state.nc.u9 .. NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES NOTIFICATION OF INTENT TO CONSTRUCT A CLOSED-.LOOP GEOTHERMAL WATER-ONLY INJECTION WELL SYSTEM (GROUND COUPLED HEAT PUMP) Type 5QW Wells In Accordance with the provisions of NCAC Title 15A: 02C .0200 Complete application and mail to address on the back page. This is not the proper form to be used for injection wells in an open-loop ~eothermal system. TO: A. Do not use this form for systems that circulate an y substances other than water. DIRECTOR, b ORTH CAROLINA DIVISION OF WATER QUALITY DATE: -3 ,200 ~ SYSTEM CLASSIFICATION Does the proposed system circulate potable water in continuous piping that completely isolates the fluid from the environment? YES X If yes, then continue completing this form. NO __ If no, do not complete this form. Form GW-57 HP, Application For Permit To Construct And/Or Use A Well(s) For Injection With A Heat Pump System, should be completed. B. SYSTEM FLUID Will any additives be introduced to the system's circulating heat transfer fluid? This includes, but is not limited to corrosion inhibitors and/ or antifreezes. C. C) YES __ If yes, do not complete this form. Form GW-57 HP, Application For rv Permit To Construct And/Or Use A Well(s) For Injection With A Heat ~ Pump System, should be completed. ~ NO X If no, then continue completing this form. PROPERTY OWNER w Name: C-4 ,tr/f!-&. kif., ~ Address: ~2'~}J r 'J tJ'"1 7/t.4Vr City: 1iz. ks d~ v, l f C-State: <:-zip Code: ~W~W-~C _____ _ County: ~.Vs ~ Telephone: -~----+-'(_0_-~Lf_.s..~s-_-~I /~~-'-------- N ~ -... D . STATUS OF PROPERTY OWNER Private: ___x_ State: GW-57CL Gan, 2000) Federal: Municipal: __ Commercial: ..)(_ Native American Lands: Pagel of4 E. JOB (SITE) DATA (Fill out ONLY if the Status of Owner is Federal, State, Municipal or Commercial). Name of Business or Facility: _____________________ _ Address: ____________________________ _ City: __________ State: __ Zip Code: ____ County: ____ _ Telephone: __________ Contact Person: ___________ _ Standard Industrial Code(s), SIC, which describes commercial facility : _______ _ F. HEAT PUMP CONTRACTOR DATA Name: Climate Control Heating & Cooling Co., Inc. Address: 102 Middle Street City: Jacksonville Telephone: (910 ) 353-9040 State: NC Zip Code: 28546 County: Onslow Contact Person: =M=i=ch=a=e=l =H=a=d=le;;..,.y ______ _ G. CONSTRUCTION DATA (check one) ____ EXISTING WELL(S) being proposed for use as a ground-coupled heat pump well(s ). Provide the information in (1) through ( 4) below to the best of your knowledge. Attach a copy of Form GW-1 (Well Construction Record) if available. X PROPOSED WELL(S) to be constructed for use as a ground-coupled heat pump well(s). Provide the information in (1) through (4) below as PROPOSED construction specifications. Submit Form GW-1 after construction. (1) Well Drilling Contractor's Name: =S=an=f=o=rd;;;..=L"""'. S:;;...;w"""e=e'-"tin""". ""g,__ ________ _ NC Contractor Certification number: NC -2082 ;:....;..;:;__.=.;;.;~----------- Date to be constructed: fo-I) Z--Number of borings: __ /_{).::.__ ____ _ 200" Approximate depth of each boring (feet):. _______________ _ (2) Well casing: Is the well(s) cased? (a) YES __ If yes, then provide the casing information below. Type: Galvanized steel __ Black steel __ ._ Plastic __ Other (specify) ____ _ Casing depth: From ___ to ___ ft. (reference to land surface) Casing extends above ground ____ inches (b) NO ---'X==----- (3) Grout (grout the vertical length of the borehole to a minimum depth of 20 feet b.l.s.): (a) Grout type: Cement __ Bentonite _x_ Other (specify) ______ _ (b) Grouted surface and grout depth (reference to land surface): ....X.... around closed loop piping; from .JL.. to _100 (feet). __ around well casing; from __ to __ (feet). NOTE: TI-IE WELL DRILLING CONTRACTOR CAN SUPPLY TI-IE DATA FOR EITHER EXISTING OR PROPOSED WELLS IF TIIlS INFORMATION IS UNAVAILABLE BY OTHER MEANS. GW-57CL Gan, 2000) Page2of4 G. INJECTION-RELATED EQUIPMENT Attach a diagram showing the engineering layout of the injection equipment and exterior piping/tubing associated with the injection operation. The manufacturer's brochure may provide supplementary information. H. LOCATION OF WELL(S) Attach two maps. (1) Include a site map (can be drawn) showing: buildings, property lines surface water bodies, potential sources of groundwater contamination and the orientation of and distances between the proposed well(s) and any existing well(s) or waste disposal facilities such as septic tanks or drain fields located within 200 feet of the ground- coupled heat pump well system. Label all features clearly and include a north arrow. (2) location map referencing the site to two nearby permanent reference points (such as roads, streams and highway intersections). (3) J. PERMIT LIST: Attach a list of all permits or construction approvals that are related to the site. Examples include: (1) Hazardous Waste Management program permits under RCRA (2) NC Division of Water Quality Non-Discharge permits (3) Sewage Treatment and Disposal Permits K. CERTIFICATION "I hereby certify, under penalty of law, that I have personally examined and am familiar with the information submitted in this document and all attachments thereto and that, based on my inquiry of those individuals immediately responsible for obtaining said information, I believe that the information is true, accurate and complete. I am aware that there are significant penalties, including the possibility of qnes and imprisonment, for submitting false information. I agree to construct, operate, maintain, repair, d if applicable, abandon the ground-source heat pump system and all related appurten in accordanca w·th the approved specifications and conditions of the Permit ' ( , :S GW-57CL Gan, 2000) of Well Owner or If authorized agent is acting on behalf of the well owner, please supply a letter signed by the owner authorizing the above agent. Page 3 of4 L. CONSENT OF PROPERTY OWNER (Owner means any person who holds the fee or other property rights in the well being constructed. A well is real property and its construction on land rests ownership in the landowner in the absence of contrary agreement in writing.) If the property is owned by someone other than the applicant, the property owner hereby consents to allow the applicant to construct each injection well as outlined in this application and that it shall be the responsibility of the applicant to ensure that the ground-source heat pump system's well(s) conforms to the Well Construction Standards (Title 15A NCAC 2C .0200) GW-57CL (Signature Of Property Owner If Different From Applicant) Please return two copies of the completed Application package to: UIC Program Groundwater Section North Carolina DENR-DWQ 1636 Mail Service Center Raleigh, NC 27699-1636 Telephone (919) 715-6165 Gan, 2000) Page 4 of 4