Loading...
HomeMy WebLinkAbout310574_Compliance Evaluation Inspection_20210408& Division of Water Resources Facility Number O Division of Soil and Water Conservation O Other Agency Visit: 0 Co P Hance Inspection O Operation Review O Structure Evaluation O Technical Assistance for Visit: Routine O Complaint O Follow-up O Referral O Emergency O Other O Denied Access Date of Visit: ®j Arrival Time: a Departure Time: County: uPL/®✓ Region: WlteO Farm Name: UsUE W"H I?TC U-T� Owner Email: Owner Name: U S LI G IZ w h 1 TTiE-P Phone: Mailing Address: Physical Address: Facility Contact: Onsite Representative: Title: Integrator: Phone: Certified Operator: Vsd)E P­ UH 'fj EP Certification Number: I (P LOL Back-up Operator: Location of Farm: Latitude: Certification Number: Design Current Design Current Swine Capacity Pop. Wet Poultry Capacity Pop. Wean to Finish Wean to Feeder Feeder to Finish / 2 O S Farrow to Wean Farrow to Feeder Farrow to Finish Gilts Boars Other Other Layer Non -Layer Design Current Dry Poultry Capacity Pon. Layers Non -Layers Pullets Turkeys Turkey Poults Other Discharges and Stream Impacts 1. Is any discharge observed from any part of the operation? Discharge originated at: ❑ Structure ❑ Application Field ❑ Other: a. Was the conveyance man-made? b. Did the discharge reach waters of the State? (If yes, notify DWR) c. What is the estimated volume that reached waters of the State (gallons)? Longitude: Design Current Cattle Capacity Pop. Dairy Cow Dairy Calf Dairy Heifer Dry Cow Non -Dairy Beef Stocker Beef Feeder Beef Brood Cow ❑ Yes 0"'No ❑ NA ❑ NE ❑ Yes No ❑ NA ❑ NE ❑ YesNo ❑ NA ❑ NE F3/ d. Does the discharge bypass the waste management system? (If yes, notify DWR) ❑ Yes . ❑ NA ❑ NE 2. Is there evidence of a past discharge from any part of the operation? ❑ Yes r ❑ NA ❑ NE 3. Were there any observable adverse impacts or potential adverse impacts to the waters ❑ Yes No ❑ NA ❑ NE of the State other than from a discharge? Page I of 3 121412015 Continued Facility Number: 3 - 5 Date of Inspection: - a Waste Collection & Treatment 4. Is storage capacity (structural plus storm storage plus heavy rainfall) less than adequate? ❑ Yes a. If yes, is waste level into the structural freeboard? ❑ Yes Structure 1 Identifier: Spillway?: Designed Freeboard (in): Observed Freeboard (in):l�_ Structure 2 Structure 3 Structure 4 5. Are there any immediate threats to the integrity of any of the structures observed? (i.e., large trees, severe erosion, seepage, etc.) 6. Are there structures on -site which are not properly addressed and/or managed through a waste management or closure plan? Structure 5 �rNq❑ NA ❑ NE No ❑ NA ❑ NE Structure 6 ❑ Yes yNo ❑ NA ❑ NE ❑ Yes �To ❑ NA ❑ NE If any of questions 4-6 were answered yes, and the situation poses an immediate public health or environmental threat, notify DWR 7. Do any of the structures need maintenance or improvement? ❑ Yes LJ No ❑ NA ❑ NE 8. Do any of the structures lack adequate markers as required by the permit? ❑ Yes �No ❑ NA ❑ NE (not applicable to roofed pits, dry stacks, and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require ❑ Yes [2No ❑ NA ❑ NE maintenance or improvement? Waste Application 10. Are there any required buffers, setbacks, or compliance alternatives that need ❑ Yes [:ZNo ❑ NA ❑ NE maintenance or improvement? 11. Is there evidence of incorrect land application? If yes, check the appropriate box below. ❑ Yes ZNo ❑ NA ❑ NE ❑ Excessive Ponding ❑ Hydraulic Overload ❑ Frozen Ground ❑ Heavy Metals (Cu, Zn, etc.) ❑ PAN ❑ PAN > 10% or 10 lbs. ❑ Total Phosphorus ❑ Failure to Incorporate Manure/Sludge into Bare Soil ❑ Outside of Acceptable Crop Window ❑ Evidence of Wind Drift ❑ Application Outside of Approved Area 12. Crop Type(s): 13. Soil Type(s): 14. Do the receiving crops differ from those designated in the CAWMP? ❑ Yes ZNo ❑ NA ❑ NE 15. Does the receiving crop and/or land application site need improvement? ❑ Yes [ o ❑ NA ❑ NE 16. Did the facility fail to secure and/or operate per the irrigation design or wettable ❑ YesE140 ❑ NA ❑ NE acres determination? 17. Does the facility lack adequate acreage for land application? ❑ Yes o ❑ NA ❑ NE 18. Is there a lack of properly operating waste application equipment? ❑ Yes ��No ❑ NA ❑ NE Required Records & Documents 19. Did the facility fail to have the Certificate of Coverage & Permit readily available? ❑ Yes No ❑ NA ❑ NE 20. Does the facility fail to have all components of the CAWMP readily available? If yes, check ❑ Yes 1;Ko ❑ NA ❑ NE the appropriate box. ❑ WUP ❑ Checklists ❑ Design ❑ Maps ❑ Lease Agreements ❑ Other: 21. Does record keeping need improvement? If yes, check the appropriate box below. [:]Yes No ❑ NA ❑ NE ❑ Waste Application ❑ Weekly Freeboard ❑ Waste Analysis ❑ Soil Analysis ❑ Waste Transfers ❑ Weather Code ❑ Rainfall ❑ Stocking ❑ Crop Yield ❑ 120 Minute Inspections ❑ Monthly and 1" Rainfall Inspections Sludge Survey 22. Did the facility fail to install and maintain a rain gauge? ❑ Yes �;O/ ❑ NA ❑ NE 23. If selected, did the facility fail to install and maintain rainbreakers on irrigation equipment? El Yes ❑ NA ❑ NE Page 2 of 3 21412015 Continued Facility Number: S 1 - 57�q I jDate of Inspection: Lf —aj 24. Did the facility fail to calibrate waste application equipment as required by the permit? ❑ Yes VNo ❑ NA ❑ NE 25. Is the facility out of compliance with permit conditions related to sludge? If yes, check [:]Yes ❑ NA ❑ NE the appropriate box(es) below. ❑ Failure to complete annual sludge survey ❑ Failure to develop a POA for sludge levels ❑ Non -compliant sludge levels in any lagoon List structure(s) and date of first survey indicating non-compliance: 26. Did the facility fail to provide documentation of an actively certified operator in charge? ❑ Yes No ❑ NA ❑ NE 27. Did the facility fail to secure a phosphorus loss assessments (PLAT) certification? ❑ Yes ❑ No 2 NA ❑ NE Other Issues 28. Did the facility fail to properly dispose of dead animals with 24 hours and/or document and report mortality rates that were higher than normal? 29. At the time of the inspection did the facility pose an odor or air quality concern? If yes, contact a regional Air Quality representative immediately. 30. Did the facility fail to notify the Regional Office of emergency situations as required by the permit? (i.e., discharge, freeboard problems, over -application) 31. Do subsurface tile drains exist at the facility? If yes, check the appropriate box below ❑ Application Field ❑ Lagoon/Storage Pond ❑ Other: ❑ Yes []/ N ❑ Yes DN"o ❑ Yes [2/No ❑ Yes [ /No ❑ NA ❑ NE ❑NA ❑NE ❑ NA ❑ NE ❑ NA ❑ NE 32. Were any additional problems noted which cause non-compliance of the permit or CAWMP? ❑ Yes [�No ❑ NA ❑ NE 33. Did the Reviewer/Inspector fail to discuss review/inspection with an on -site representative? ❑ Yes E2,<o ❑ NA ❑ NE 34. Does the facility require a follow-up visit by the same agency? ❑ Yes [Z/No ❑ NA ❑ NE Comments (refer to question #): Explain any YES answers and/or any additional recommendations or any other comments. Use drawines of facilitv to better explain situations (use additional Daizes as necessarv). Ad, Aae.rwad fri L'JuP, ()P-*► has Pa -A r i o.r a.3a0 , 3i �W WQl j� l@a��'-►�q ar �l�e ka` (,v S2. on4 rvn S evL N"z 4 d5P. of the Se --y Nr PO 1s"ICS ,As Reviewer/Inspector Name Reviewer/Inspector Signature: Page 3 of 3 H r� t'e 2X-y Phone: 61/o -9 -77 Date: Lf' ?3—� 511212020