HomeMy WebLinkAboutSW8970241_COMPLIANCE_19971208STORMWATER DIVISION CODING SHEET
POST -CONSTRUCTION PERMITS
PERMIT NO. SW
DaC TYPE ❑CURRENT PERMIT
❑ APPROVED PLANS
❑ HISTORICAL FILE
COMPLIANCE EVALUATION INSPECTION
DOC DATE `Qg
YYYYMMDD
INFILTRATION BASIN ANALYSIS
PROJECT NAME: Boardwalk RV Park
DRAINAGE BASIN: Bogue Sound
SITE AREA: 513572 SF
IMPERVIOUS AREA CALCULATION
BUILDINGS
PARKING/ASPHALT
CONCRETE
OTHER
FILENAME: S:IWQSIINBASIN1970241.WK1
PROJECT #: 970241 DATE:
CLASS: SA REVIEWER: art
DRAINAGE AREA: 447779 SF
150 lots a 500
TOTAL
% IMPERVIOUS= 35.7283392 % RV=
ELEVATION OF SEASONAL HIGH WATER TABLE
REPORTED HYDRAULIC CONDUCTIVITY
SURFACE AREA OF BASIN BOTTOM
SURFACE AREA AT STORAGE ELEVATION
BOTTOM ELEVATION OF BASIN
STORAGE ELEVATION
VOLUME / DEPTH / DRAWDOWN CALCULATION
TOTAL VOLUME TO INFILTRATE
TOTAL VOLUME AVAILABLE
DEPTH OF RUNOFF
TIME TO DRAWDOWN
4686 SQUARE FEET
79222 SQUARE FEET
1076 SQUARE FEET
75000 SQUARE FEET
159984 SQUARE FEET
.05 + .009 (1)= 0.37155505
8.33 FEET MSL
0.15 CF/HR/SF
17000 SQUARE FEET
21275 SQUARE FEET
10.5 FEET MSL
13 FEET MSL
45293 CF (106,656-61363)
47843.75 CUBIC FEET
2.366715 FEET
18.76225 HOURS MUST BE <120
COMMENTS
Volume and drawdown are (not) within Design Requirements.
08-Dec-97
INFILTRATION BASIN ANALYSIS
PROJECT NAME: Boardwalk RV Park
DRAINAGE BASIN: Bogue Sound
SITE AREA: 513572 SF
IMPERVIOUS AREA CALCULATION
155 lots rr 500 sf per lot
PARKING/ASPHALT
Clubhouse
% IMPERVIOUS= 35.1253632 %
ELEVATION OF SEASONAL HIGH WATER TABLE
REPORTED HYDRAULIC CONDUCTIVITY
SURFACE AREA OF BASIN BOTTOM
SURFACE AREA AT STORAGE ELEVATION
BOTTOM ELEVATION OF 13ASIN
STORAGE ELEVATION
VOLUME / DEPTH / DRAWDOWN CALCULATION
TOTAL VOLUME TO INFILTRATE
TOTAL VOLUME AVAILABLE
DEPTH OF RUNOFF
TIME TO DRAWDOWN
FILENAME: S:IWQSIINBASIN1970241.WK1
PROJECT #: 970241 DATE:
CLASS: SA REVIEWER: ari
DRAINAGE AREA: 447779 SF
77500 SQUARE FEET
74022 SQUARE FEET
5762 SQUARE FEET
SQUARE FEET
TOTAL 157294 SQUARE FEET
RV= .05 + .009 (1)= 0.36612827
8.33 FEET MSL
0.15 CF/HR/SF
17000 SQUARE FEET
21275 SQUARE FEET
10.5 FEET MSL
13 FEET MS1,
43493 CF `(Mk5 �63k
47843.75 CUBIC FEET
2.272658 FEET
18.76225 HOURS MUST BE <120
COMMENTS
Volume and drawdown are (not) within Design Requirements.
20-Aug-98