Loading...
HomeMy WebLinkAboutSW8020503_HISTORICAL FILE_20110811STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW Xu�D�j DOC TYPE ❑CURRENT PERMIT ❑ APPROVED PLANS HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE YYYYMMDD Arr NICDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Governor Director August 11, 2011 Mr. David Nathans, President Plantation, Inc. P.O. Box 2473 Wilmington, NC 28402 Subject: PERMIT RENEWAL REQUEST Stormwater Permit No. SW8 020503 City Block New Hanover County Dear Mr. Nathans: Dee Freeman Secretary The Division of Water Quality issued a Coastal Stormwater Management Permit, Number SW8 020503 to Plantation, Inc. for a High Density project on July 22, 2002. This permit expires on July 2, 2012, Per 15A NCAC 21-1.1003(h) (the stormwater rules), applications for permit renewals shall be submitted 180 days prior to the expiration of a permit and must be accompanied by a processing fee, which is currently set at $505.00. If this is still an active project please complete and submit the enclosed renewal application prior to January 22, 2012. If this project has not been constructed and a permit is no longer needed, please submit a request to have the permit rescinded. If you have sold the project please provide the name, mailing address and phone number of the person or entity that is now responsible for this permit. Enclosed is a form for change of ownership, which should be completed and submitted if the property has changed hands. Your permit requires that upon completion of construction and prior to operation of the permitted stormwater treatment system, a certification of completion be submitted to the Division from an appropriate designer for the type of system installed. This is to certify that the permitted facility has been installed in accordance with the permit, the approved plans, specifications and supporting documentation. If you have not already provided a Designer's Certification to our office, please include a copy with your permit renewal request and processing fee. A copy of the certification form is enclosed for your convenience. You should be aware that failure to provide the Designer's Certification and the operation of a stormwater treatment facility without a valid permit, are violations of NC General Statute 143-215.1 and may result in appropriate enforcement action including the assessment of civil penalties of up to $10,000 per day. If you have any questions, please feel free to contact David Cox at (910) 796-7318. Sincerely, Georgette Scott Stormwater Supervisor GDSldwc S:1WQS1Stormwater\Permits & Projects12002 \020503 HD12011 08 req_ren cc: Wilmington Regional Office File encl. Wilmington Regional Office 127 Cardinal Drive Extension, Wilmington, North Carolina 28405 Phone: 910-796-72151 FAX: 910.350-2004 1 Customer Service: 1-877-623-6748 Internet: www.ncwaterquality.org No hCarofina ;Vatura!!y An Equal Opponunity 1 Affirmative Action Employer SOS1D:0436786 Date Filed: 6/10/2010 8:53:00 AM M-478 (42) Business Corporation North Carolina An Elaine F. Marshall 1f1-28Ot3 Nortlt Carnlina Secrcfxry of Stxtc This report may be filed online at the Secretary of State website: CA201017400269 Name of Bus. Corporation: PLANTATION BUILDING CORP. Fiscal Year Ending: 12 31 09 State of tncorporation: NC Month 1 Day / Year Secretary of State ID Number: 0436786 ❑I hereby certify that the Information! requested below (required by NCGS 55-16-22) has not changed since the most recentty filed annual report and is therefore complete. Nature of Business: GENERAL CONTRACTOR Registered Agent: DAVID A. SPETRINO, JR . Registered Office Mailing Address: 720 N . 3 RD STREET, STE . 301 County: NEW HANOVER City: WILMINGTON State: NC zipcode:28401 Registered Office Street Address: PO BOX 2473 County: NEW HANOVER City: WILMINGTON Signature of New Registered Agent: (Signature constitutes consent to the appointment) Principal Office Telephone Number: 910 — 7 6 3— 8 7 6 0 Principal Office Mailing Address: PO BOX 2473 city: WILMINGTON Principal Office Street Address: 720 N. 3RD STREET, STE. City: WILMINGTON Name, Title, and Business Address of Principal Officers: State: NC Tip Code: 28402 State: NC Zip Code: 2 8 4 0 2 State: NC Zip Code: 28401 Name: DAVID A. SPETRINO, JR Title. PRESIDENT Address: 10 CHURCH STREET City: WILMINGTON State: NC Tap: 28401 Name: KATHRYN R. SPETRINO Title: SECRETARY Address: 10 CHURCH STREET City: WILMINGTON state: NC Tap: 28401 Name: Title: Address: City: State: Zip: Ce ' tipn at annual report (Must be cornpleted by all Business Corporations), Signature iForm must bo Signed by an officer of corporation) 'AA.►,� q WC-rcrwo 1R.- Type or Print Name 4 it, Date %L TattSt�Torr TIW OF WATER Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E.,Director Division of Water Quality Coleen H. Sullins, Deputy Director Division of Water Quality March 23, 2004 Mr. David Nathans, President Plantation, Inc. PO Box 2473 Wilmington, NC 28402 Subject: Approved Plan Revision City Block Stormwater Project No. SW8 020503 New Hanover County Dear Mr. Nathans: On February 20, 2004, the Wilmington Regional Office received a plan revision for Stormwater Management Permit Number SW8 020503. The revisions include the increase of the building area for Brooklyn House, and a decrease in the sidewalk and parking lot area'such that the total is still under the 46,476 ft that was originally permitted . It has been determined that a formal permit modification is not required for the proposed changes. We are forwarding you an approved copy of the revised approved plans for your files. Please add this sheet to the originally approved plan set. Please be aware that all terms and conditions of the permit issued on July 22, 2000, remain in full force and effect. Please also understand that.the approval of this revision to the approved plans for the subject State Stormwater Permit is done on a case -by - case basis. Any other changes to this project must be approved through this Office prior to construction. The approved changes must be constructed as shown on the revised, approved plans. If you have any questions concerning this matter, please do not hesitate to call me at (910) 395-3900.. Sincerely, Linda Lewis Environmental Engineer RSSlarl: S:IWQSISTORMWATIREVISION1020503.mar04 cc: Phil Tripp, P.E., Tripp Engineering Tony Roberts, New Hanover County Building Inspections Linda Lewis Wilmington- Regional-Ofl'icP' Central Files N. C. Division of Water Quality 127 Cardinal Drive Extension (910) 395-3900 Customer Service Af#A Wilmington Regional Office Wilmington, NC 28405 (910) 350-2004 Fax 1 800 623-7748 NCDENR TRIPP ENGINEERING, P.C. 419 Chestnut Strcet Wilmington, North Carolina 25401 Phone: (910) 763-5100 • FAX: (910) 763-5631 February 20, 2004 NCDENR Division of Environmental Management Water Quality Section 127 Cardinal Drive Wilmington, NC 28405-3845 Attn: Ms. Linda Lewis Re: Brooklyn House Dear Linda: 0 In response to your email dated 01-06-04, I hope the following numbers will help calculate the drainage area for the project (Brooklyn House). As built Proposed Future Total Permitted Buildings 5,875 9,000 3,350 18,225 17,473 Sidewalk 11,693 11,693 12,596 On site parking 15,844 15,844 16,407 45,762 46,476 As you can see, by increasing the proposed building s.f. the sidewalk area has been reduced, as has the on -site parking area. I am enclosing a copy of the original project with highlighted drainage areas, and the current project (Brooklyn House) with the originally permitted infiltration trench details. Could you please review these and contact us with any comments. Sincerely, Tripp Engineering, P.C. Jacqueline King jk:dcb For Charlie- Brooklyn House City Block 020503 Subject: For Charlie- Brooklyn .House City Block 020503 From: Linda Lewis <Linda.Lewis@ncmail.net> Date: Tue, 06 Jan 2004 17:02:48 -0500 To: Phil Tripp <trippeng@ec.rr.com> Charlie. I'm still having some trouble with this plan revision. When I at the original plans, it appears that everything between the buildings is intended to be grassed, because I cannot see any regarding the proposed material to be installed. If it wasn't marked specifically as BUA, it is assumed as grass. look notes Further, the drainage area for trenches A, B, and AB is 51,836 sq. ft., and the permitted impervious is 46,476, meaning that there is 5,360 sq. ft.. of "open" area somewhere within it. I am hard-pressed to find it, based on the revised site plan. It appears to me to be almost entirely impervious now. If you can mark up a site plan that clearly shows the open areas and do a quick calculation of that open area, demonstrating that there is 5,360 sq. ft. of pervious area within that one drainage area, I'll move on with it. Additionally, I have added the trench identifiers B, C, D and E, to the revised plan in red. Please remember that if we replace an approved plan sheet with a revised one, it MUST contain ALL of the previously permitted information that is not being changed as a result of the modification. That plan sheet will be used to determine the future compliance of the entire project for the life of the project, not just the Brooklyn House part. Also, the new detail sheet does not contain the previously approved trench section details. Please remove the new sheet from the approved plan set and just use the previously permitted detail sheet. Thanks, Linda 1 of 1 1 /6/2004 5:04 PM City Block SW8 020503 Subject: City Block SW8 020503 From: "Phillip Tripp" <t6ppeng a@ec.rr.com> Date: Mon, 15 Dec 2003 14:29:24 -0500 To: "Linda Lewis" <linda.lewis@ncmaii.net> Linda, In response to your correspondence dated December 12, 2003 for City Block (SW8 020503), we offer the following: • Yes, the building is slightly larger, but it displaces areas that were already impervious (i.e. sidewalks). • The areas of brick -like pattern have always been accounted for as built -upon area in all previous plans. • The current landscaping requirements bring forth a reduction in the previously permitted sidewalk areas. Therefore, the proposed built upon area is now less than the originally permitted area. Please contact us with any questions, comments or if you need any additional information. Thank you. Charles Cazier, E.I. Tripp Engineering 1 of 1 12/19/2003 5:11 PM FILE MODE -805 MEMORY T COMMUNICATION RESULT REPORT ( DEC.12.2003 1:57PM OPTION ----REASON -FOR ERROR E-1) HANG UP OR LINE FAIL E-3) NO R14SWER ADDRESS (GROUP) - 9-7635631 RESULT OK P. 1 NCDENR WIRO PAGE / ---------- �- P. 1/1 E-2) BUSY E-4) NO FACSIMILE CONNECTION Q WAr �4 Michael F. Easley, Governor Q William G. Ross Jr. Secretary Ap North Carolina Department of Environment and Natural Nesources Alan W. Klimek P.E.,Dlrector p Division ofWater Quality Coleen M, Sullins, De uty Director Division of Water Quality FAX COVER SHEET Date: December 12, 2003 To- Phil Tripp, P.E. Company: Tripp Engineering FAX #: 763-5631 No. of Pages: 1 AV From: Linda Lewis Water Quality Section - Stormwater FAX # 910-350.2004 Phone # 910-395-3900 DWQ Stormwater Project Number: SW8 020503 Project Name: City Block MESSAGE: Phil: The last revision, dated November 4, 2002, indicated that within the area of the proposed Brooklyn House, there are three buildings, totaling 8,590 square feet. This latest revision is showing a 9,000 square foot structure. Additionally, the revised plans now show a brick -like pattem in all of the spaces L,-A..._-- 4@_ . I ., . . . . . ..- 0� WATFy Michael F. Easley, Governor `a Q William G. Ross Jr., Secretary ,CA North Carolina Department of Environment and Natural Resources co Alan W. Klimek, P.E.,Director p Division of Water Quality Coleen H. Sullins, Deputy Director Division of Water Quality FAX COVER SHEET Date: December 12, 2003 No. of Pages: 1 To: Phil Tripp, P.E. From: Linda Lewis Company: Tripp Engineering Water Quality Section - Stormwater FAX #: 763-5631 FAX # 910-350-2004 Phone # 910-395-3900 DWQ Stormwater Project Number: SW8 020503 Project Name: City Block MESSAGE: Willi The last revision, dated November 4, 2002, indicated that within the area of the proposed Brooklyn House, there are three buildings, totaling 8,590 square feet. This latest revision is showing a 9,000 square foot structure. Additionally, the revised plans now show a brick -like pattern in all of the spaces between the buildings labeled as "Future pedestrian walkway (Open Space)" . Was this area previously grassed area, or was it accounted for as built -upon originally? RSSlarl: S:1WQSlSTORMWATIADDINFO\20031020503.decO3 N. C. Division of Water Quality 127 Cardinal Drive Extension (910) 395-3900 Customer Service Wilmington Regional Office Wilmington, NC 28405 (910) 350-2004 Fax 1 800 623-7748 NCDEI'v'3t 0 w A TFR0 G 7 r_ Mr. David Nathans, President Plantation, Inc. PO Box 2473 Wilmington, NC 28402 Dear Mr. Nathans: Michael F. Easley, Governor William G. Rass, Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E., Director Division of Water Quality Wilmington Regional Office November 4, 2002 Subject: Approved Plan Revision City Block Stormwater Project No.SW8020503 New Hanover County On September 11, 2002 , the Wilmington Regional Office received a plan revision for Stormwater Management Permit Number SW8020503. It has been determined that a formal permit modification is not required for the proposed changes. We are forwarding you an approved copy of the revised plans for your files. Please replace the old approved plan sheet(s) with the new one(s). Please be aware that all terms and conditions of the permit issued on July 22, 2000, remain in full force and effect. Please also understand that the approval of this revision to the State Stormwater Permit is done on a case -by -case basis. Any other changes to this project must be approved by this office prior to construction. If it is determined that the proposed revision will require a modification to the permit, you will be notified. If you have any questions concerning this matter, please do not hesitate to call me at (910)395-3900. Sincerely, Noelle Lutheran Environmental Tech V RSSlnml: S:1WQSISTORMWATIREVISiON1020503Nov cc: -Noelle-Lutheran-\ Phil Tripp, Tripp Engineering New Hanover Building Inspections Central Piles NCI)Eh'.R N.C. Division of Water Quality 127 Cardinal Drive Extension Wilmington, N.C. 28405 (910) 395-3900 Fax (910) 350-2004 Customer Service 800-623-7748 TRIPP ENGINEERING, P.C. 419 Chestnut Street Wilmington, North Carolina 28401 Phone: (910) 763-5100 • FAX: (910) 763-5631 sE� 1 l zaaz September 11, 2002 NCDENR BY : Division Water Quality 127 Cardinal Drive Wilmington, NC 28405-3845 Attn: Ms. Noelle Lutheran Re: City Block SW8 020503 New Hanover County, NC TE 01141 Dear Noelle: As per our phone conversation, we have adjusted the location of some of the trenches. The net change of volume is +71.24 cf. The length of 24" pipe has been changed to +l 5 If, 12" pipe to +20 If, and 6" pipe to +45 If. Enclosed please find two (2) sets of plans and one adjusted underground infiltration supplement form. Please review for approval and contact us with any questions, comments or if you need additional information. Thank you. Sincerely, Tripp Engineering, P.C. C421Z 0- . Charles D. Cazier, E.I. CDCAcb Eric, Permit No. S-Wg (to be provided by DIVQJ State of North Carolina Department of Environment and Natural Resources Division of Water Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM UNDERGROUND INFILTRATION TRENCH SUPPLEMENT This form may be photocopied far use as an original DWQ Stormwater Management Plan Review: A complete stormwater management plan submittal includes a stormwater management permit application, an underground infiltration trench supplement for each system, design calculations, and plans and specifications showing all stormwater conveyances and system details. 1. PROJECT INFORMATION Project Name: k Contact Person: Charles Cazier Phone Number: 910 763-5100 For projects with multiple infiltration systems, a supplement form must be completed for each system. This worksheet applies to: Trench _A & B & AB in Drainage Area 2 (from plans) (from Form SWU-101) 11. DESIGN INFORMATION (attach supporting calculations/documentation): Soils Report Summary (based uport an actual field investigation and soil horings) Soil Type Orange tan fine to medium sand Infiltration Rate 42 n/hr or cf/hr/sf (circle appropriate units) SHWT Elevation 37 fmsl (Seasonal High Water Table elevation) `french Design Parameters Design Volume 3873 c.f. Design Storm Drawdown Time Perforated Pipe Size Perforated Pipe Length No. Observation Wells Stone Type (if used) Stone Void Ratio 1.0 inch event (1.5 inch event for SA waters, I inch event for others) 1.14 days hours b", 1_ 2 24"inch diameter 309', 240', 15 P ft. NA #57 crushed granit 0.40 'french Elevations (in feet mean sea level) Bottom Elevation 47.5 fmsl Storage/Overflow Elevation 51.5 fmsl (may he required on a case-hy-case basis) SWU-107 Rev3.99 Page t of Trench Dimensions Fleight -4 � ft. Length 265 ft. Width _varies ft (10', 20', 30') 111. REQUIRED ITEMS CHECKLIST Volume Provided 7135.24 cu.ft. The following checklist outlines design requirements per the Stormwater Best Management Practices manual (N.C. Department of Environment, Health and Natural Resources, November 1995) and Administrative Code Section: 15 A NCAC 2H .1008. Initial in the space provided to indicate the following design requirements have been met and supporting documentation is attached. If the applicant has designated an agent in the Stormwater Management Permit Application Form, the agent may initial below. Attach justification if a requirement has not been met. Applicants Initials C_ 7P a. System is located 50 feet from class SA waters and 30 feet from other surface waters. G b. System is located at least 100 feet from water supply wells. G c. Bottom of system is at least 2 feet above the seasonal high water table. d. Bottom of the system is 3 feet above any bedrock or impervious soil horizon. cM _ e. Off-line system, runoff is excess of the design volume bypasses the system (bypass detail provided). f. System is designed to draw down the design storage volume to the proposed bottom elevation under seasonal high water conditions within five days based upon infiltration through the bottom only (a hydrogeologic evaluation may be required). GTc� g. Soils have a minimum hydraulic conductivity of 0.52 inches per hour. C <= h. System is not sites on or in fill material or DWQ approval has been obtained. v DL _ i. Plans ensure that the installed system will meet design specifications (constructed or restored) upon initial operation once the project is complete and the entire drainage area is stabilized. -C j. System is sized to take into account the runoff at the ultimate built -out potential from all surfaces draining to the system, including any off -site drainage. k. System is located in a recorded drainage easement for the purposes of operation and maintenance and has recorded access easements to the nearest public right-of-way. 1. System captures and infiltrates the runoff from the first 1.0 inch of rainfall (1.5 inch event for areas draining to SA waters). m. Drainage area for the device is less than 5 acres. n. A pretreatment device ( filter strip, grassed swale, sediment trap, etc.) is provided. o. Trench bottom is covered with a layer of clean sand to an average depth of 4 inches. p. Sides of infiltration trench are lined with geotextile fabric. ef _ q. Rock used is free of fines (washed stone) and has large void ratio. r. Side to bottom ratio is less than 4:1. SWU-107 Rev 3.99 Page 2 of 4 9/10/2002 CDC WATERSHED DATA Total Drainage Area s . ft. acres 51,774 1.19 CITY BLOCK Infiltration Trench A B 10-year Storm Impervious Area Land Use s , ft. I acres buildings___ 17,473 0.40 park in las halt 16,407 0.38 concrete 12,596 �46,476 0.29 Total 1,07 INFILTRATION SYSTEM: Volume of first inch of runoff = (impervious area)1112 V= 3,873.00 cu-ft Volume of pipe provided= Area x Length Vpipe6"= 60,64 cu-ft Vpipel2"= 189.16 cu-ft Vpipe24"= 474.10 cu-ft Volume of trench provided= (LxWxD) - total pipe volume Vtp= 16,028,34 cu-ft Storage volume provided= (Vtp `0.40) + total pipe volume V = 7,135.24 cu-ft DRAWDOWN TIME: Depth of infiltration system: D= 4 ft. Infiltration Rate of soils: R= 42 inlhr Drawdown time: DDT= 1.14285714 hrs, ``\\\\1111i111tt!!/ C,AR011���i,,�` ?9 SEAL 9rti 17374GRE Q 11111I i1 09.10.OZ. f °% impervious = 0.898 = 89.8°% say 90.0°% CPRE = 0.25 CPOST = (°% imp.)(.95)+(1-0% imp,)(.25) 0,88 110 = 7.23 inlhr 125 = 3.15 inthr 01141 TRIPP ENGINEERING, P.C. 419 Chestnut Street, Wilmington, NC 28401 Phone: (910) 763-5100 • FAX: (910) 763-5631 Email: trippeng@ec.rr.com 1 r I LETTER OF TRANSMITTAL To: Attention:iS Subject: FAX TRANSMITTAL: NUMBER OF PAGES INCLUDES COVER I am sending you: ( ) ATTACHED ( ) UNDER SEPARATE COVER ( -1--Prints ( ) Tracings ( ) Copy of letter ( ) Specifications ( ) Other Copies Item No. Description ,-1— These are transmitted as checked below: ( ).Far Approval ( ) For Your Use { } Sign & Return { -review Remarks: cc: TRIPP ENGINEERING, P.C. 419 Chestnut Street, Wilmington, NC 28401 Phone: (910) 763-5100 - FAX: (910) 763-5631 Email: trippeng@ec.rr.com LETTER OF TRANSMITTAL To: , D N1 Attention: L,1&. Lf(& )is _ Subject: FAX TRANSMITTAL: NUMBER OF PAGES INCLUDES COVER I am sending you: ( ) ATTACHED ( ) UNDER SEPARATE COVER ( ) Prints ( ) Tracings ( ) Copy of letter ( ) Specifications ( } Other These are transmitted as checked below: ( }.For Approval ( -J"For Your Use ( ) Sign & Return ( } Review Remarks: cc: 9-�- M1-4M_'M'k 6W�� TRIPP ENGINEERING, P.C. 419 Chestnut Street Wilmington, North Carolina 28401 Phone: (910) 763-5100 - FAX: (910) 763-5631 December 8, 2003 NCDENR Division of Environmental Management Water Quality Section 127 Cardinal Drive Wilmington, NC 28405-3845 Attn: Ms. Linda Lewis Re: Laurel Oaks SW8020503 Dear Linda: For your information we are currently seeking approval from the City of Wilmington for a phase of the project (Laurel Oaks) SW8020503. This phase was designated as future development with a permitted impervious building area of 8,611 sf, and a paved area of 2,055 sf within the tract area of 11,684 sf. Our proposed plans are calling for a building area of 9,000 sf and a paved area of 1,448 sf, which is less impervious than originally permitted. The City is asking us for your approval before release of a permit. 1 am enclosing a copy of the original project (Laurel Oaks) with tract area highlighted, and the current project (Brooklyn House). Could you please review these and contact us with any comments. Sincerely, Tripp Engineering, P.C. GGG i Jacqueline King jk:dcb State Stormwater.Management Systems Permit No. SW8 020503. STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Plantation, Inc. City Block New Hanover County :a FOR THE :} r • Y C�. . construction, operation and maintenance of four infiltration trench systems in compliance with the provisions of 15A NCAC 2H .1000 (hereafter referred to as the "stormwater rules") and the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Water Quality and considered a part of this permit. This permit shall be effective from the date of issuance until July 22, 2012, and shall be subject to the following specified conditions and limitations: 1. DESIGN STANDARDS 1. This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data. 2. This stormwater system has been approved for the management of stormwater runoff as described on page 3 of this permit, the Project Data Sheet. The stormwater controls have been designed to handle the runoff from 71,849 square feet of impervious area. 3. The tract will be limited to the amount of built -upon area indicated on page 3 of this permit, and per approved plans. 4. All stormwater collection and treatment systems must be located in either dedicated common areas or.recorded easements. The final plats for the project will be recorded showing all such required easements, in accordance with the approved plans. 5. The runoff from all built -upon area within the permitted drainage area of this project must be directed into the permitted stormwater control system. A permit modification must be submitted and approved prior to the construction of additional built -upon area from outside of the approved drainage area. 2 f State Stormwater Management Systems Permit No. SW8 020503 DIVISION OF WATER QUALITY PROJECT DESIGN DATA SHEET Project Name: City Block Permit Number: SW8 020503 Location: New Hanover County Applicant: Mr. David Nathans, President Mailing Address: Plantation, Inc. PO Box 2473 Wilmington, NC 28402 Application Date: July 16, 2002 Receiving Stream/River Basin/Index #: Cape Fear / Cape Fear River/ 18-(7 1) Classification of Water Body: "SC" Trench Number: A,B,AB C D E Pond Depth, feet: 4 4 4 4 Permanent Pool Elevation, FMSL: 47.5 46.5 42 40 Drainage Area, acres: 51,836 12,197 5,663 13,939 Total Impervious Surfaces, ftz: 46,476 8,712 4,382 12,280 Offsite Area entering Pond, ftz: none per Engineer Required Storage Volume, ft3: 3,873 720 365 1,023 Provided Storage Volume, ft3: 7,064 1,528 1,072 1,698 Temporary Storage Elevation, FMSL: 51.5 50.5 46 44 Controlling Orifice: Infiltration Drop Inlet with Overflow Type of Soil: Orange Tan Fine to Medium Sand Expected Infiltration Rate: 42" per hour SHWT Elevation, FMSL: 37 Time to Drawdown, hrs: 1.14 State Stormwater Management Systems Permit No. SW8 020503 II. SCHEDULE OF COMPLIANCE The stormwater management system shall be constructed in it's entirety, vegetated and operational for its intended use prior to the construction of any built -upon surface. 2. During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately. 3. The permittee shall at all times provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency. The approved Operation and Maintenance Plan must be followed in its entirety and maintenance must occur at the scheduled intervals including, but not limited to: a. Semiannual scheduled inspections (every 6 months). b. Sediment removal. C. Mowing and revegetation of slopes and the vegetated filter. d. Immediate repair of eroded areas. e. Maintenance of all slopes in accordance with approved plans and specifications. f. Debris removal and unclogging of outlet structure, orifice device, flow spreader, catch basins and piping. g. Access to the outlet structure must be available at all times. 4. Records of maintenance activities must be kept and made available upon request to authorized personnel of DWQ. The records will indicate the date, activity, name of person performing the work and what actions were taken. 5. Decorative spray fountains will not be allowed in the stormwater treatment system. 6. The facilities shall be constructed as shown on the approved plans. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 7. Upon completion of construction, prior to issuance of a Certificate of Occupancy, and prior to operation of this permitted facility, a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation. Any deviations from the approved plans and specifications must be noted on the Certification. A modification may be required for those deviations. 8. If the stormwater system was used as an Erosion Control device, it must be restored to design condition prior to operation as a stormwater treatment device, and prior to occupancy of the facility. 9. The permittee shall submit to the Director and shall have received approval for revised plans, specifications, and calculations prior to construction, for any modification to the approved plans, including, but not limited to, those listed below: a. Any revision to any item shown on the approved plans, including the stormwater management measures, built -upon area, details, etc. b. Project name change. c. Transfer of ownership. d. Redesign or addition to the approved amount of built -upon area or to the drainage area. e. Further subdivision, acquisition, or sale of the project area. The project area is defined as all property owned by the permittee, for which Sedimentation and Erosion Control Plan approval or a CAMA Major permit was sought. f. Filling in, altering, or piping of any vegetative conveyance shown on the approved plan. 4 I State Stormwater Management Systems Permit No. SW8 020503 10. The permittee shall submit final site layout and grading plans for any permitted future areas shown on the approved plans, prior to construction. If the proposed BUA exceeds the amount permitted under this permit, a modification to the permit must be submitted and approved prior to construction. 11. A copy of the approved plans and specifications shall be maintained on file by the Permittee for a minimum of ten years from the date of the completion of construction. 12. Prior to the sale or lease of any portion of the property, the permittee shall notify DWQ and provide the name, mailing address and phone number of the purchaser or leasee. An access/maintenance casement to the stormwater facilities shall be granted in favor of the permittee if access to the stormwater facilities will be restricted by the sale or lease of any portion of the property. 13. The permittee must maintain compliance with the proposed built -upon area and ensure that the runoff from all the built -upon is directed into the permitted system. 14. The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit. Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements. The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made. III. GENERAL CONDITIONS This permit is not transferable. In the event there is a desire for the facilities to change ownership, or there is a name change of the Permittee, a formal permit request must be submitted to the Division of Water Quality accompanied by an application fee, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. Responsibility for compliance with all permit conditions remains with the Permittee until such time as the Division approves the formal permit request. 2. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to enforcement action by the Division of Water Quality, in accordance with North Carolina General Statute 143-215.6A to'143-215.6C. 3. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. 4. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems. 5. The permittee grants DENR Staff permission to enter the property during normal business hours for the purpose of inspecting all components of the permitted stormwater management facility. 6. The permit may be modified, revoked and reissued or terminated for cause. The filing of a request for a permit modification, revocation and reissuance or termination does not stay any permit condition. 7. Unless specified elsewhere, permanent seeding requirements for the stonmwater control must follow the guidelines established in the North Carolina Erosion and Sediment Control Planning and Design Manual. E State Stormwater Management Systems Permit No, SW8 020503 Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit. 9. The permittee shall notify the Division any name, ownership or mailing address changes within 30 days. Permit issued this the 22nd day of July, 2002. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION _ Alan W. Klimek, h.E.,-Director ✓�1 Division of Water Quality By Authority of the Environmental Management Commission no I State Stormwater Management Systems Permit No. SW8 020503 City Block Stormwater Permit No. SW8 020503 New Hanover County Designer's Certification as a duly registered in the State of North Carolina, having been authorized to observe (periodically/weekly/full time) the construction of the project, (Project) for (Project Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. The checklist of items on page 2 of this form is included in the Certification. Noted deviations from approved plans and specification: Signature Registration Number Date SEAL 7 State Stormwater Management Systems Permit No. SW8 020503 Certification Requirements: l . The drainage area to the system contains approximately the permitted acreage. 2. The drainage area to the system contains no more than the permitted amount of built -upon area. 3. All the built -upon area associated with the project is graded such that the runoff drains to the system. 4. The outlet/bypass structure elevations are per the approved plan. .5. The outlet structure is located per the approved plans. b. Trash rack is provided on the outlet/bypass structure. 7. All slopes are grassed with permanent vegetation. 8. Vegetated slopes are no steeper than 3:1. 9. The inlets are located per the approved plans and do not cause short-circuiting of the system. _10. The permitted amounts of surface area and/or volume have been provided. 11. Required drawdown devices are correctly sized per the approved plans. _12. All required design depths are provided. _13. All required parts of the system are provided, such as a vegetated shelf, and a forebay. _14. The overall dimensions of the system, as shown on the approved plans, are provided. cc: NCDENR-DWQ Regional Office New Hanover, New Hanover County Building Inspections i 5/2102 CDC WATERSHED -DATA Total Area ft. acres 51,774 1.19 CITY BLOCK hfittration Trench A B 10-year Storm impervious "Area Land Use sq. ft. aces 17,473 l240 16,407. 0.3B concrete 12,596 0.29 Total 46,476 1.07 INFILTRAPON SYSTEM: Volume af7irst inch of runoff = (impervious area)1/12 V= 3,673.00 cu-ft Volume of pipe provided= Area x Length Vpipe6'= 51,81 cu-ft Vpipe12"= 173.40 cu-ft Vpipe24'= 427.00 cu-ft Volume of trench provided= (LxWxD) - total pipe volume Vtp= 16,028.34 cu - t volumes pnw&(scf= (Vtp ' 0.40 +Iota! p+pe vohm .. Vp= 7,063.55 cu-ft DRAWDOWM TIME: Depth ofinfdGatbn system: D= 4 ft. lnMra6on Rate of sorts: R= 42 iNhr Drawdown time: DOT= 1.14285714 hrs. % impervious = 0.898 89.6% say 90.0% CPRE = 0.25 CPOST = (% Imp.)(.95)+(1-% imp.)(.25) 0.88 110 = 7.23 inthr 125 = -6.15 inifn 01141 e' 5/2102 CDC WATERSHED DATA Total Drainage Area ft, Iacres 1z,= 0:28 CITY BLOCK Infiltration Trench C. 10-year Storm Impervious Area Land Use sq. ft. acres Mtn 6,206 0.14 o.. (Loa concrete 2,506 0.06 Total 8,712 020 INFILTRAT;GWSYSTEM: Volume of first inch of rurroff = (rmpen4ous area)1/12 V= 72e.00- aFft Vaha=of pipe pmuide = Area x Leagffi Vpipe24"= 280.00 cu-ft Volume of trench provided= (LxWxD) - total pipe volume Vtp= 3,120.00 cu-ft volume provided= (Vtp " 0.I$M + tbtaf pipe volume Vp=' t526.OD, cuft DRAWDOWN TIME: Depth of inWa8on system: D= 4 ft_ kdatratxo Rate of saris: R= 42 irWhr Drawdown time. DOT= 1,14285714 hrs. % impervious = 0.714 = 71.4% say 72_0% CPRE = 0.25 CPOST =, (% imp.u95)+(1-% irnp.u25) = 0.75 110 = 7.23 in/hr 125 = 8.15 inlhr 01141 5/2102 CDC WATERSHED DATA Total Drai Aree ft acres 5,702 0:13`- CITY BLOCK Infii1ration Trench 0 10-year Storm Imperykws Area Land Use- sq., ft: acres 6aildt 3 232 0,07 13 a.00 concrete 1,150 0.03 Total 4,382 0.10 IRF1LTFJn7OiQ SYST7E17f:' Volume of first inch of runoff = (impervious area)1112 V= 365:t7 cu-it Volume of pipe pmuided= Area x r ength Vpipe24'= 188.00 cu-ft Volume of trench provided= (LxWxD) - total pipe volume Vtp= 2,212.00 cu-ft vofErme provided= (Vtp ' 114Z7 f total ,pipe volume - _� 1,07284 cu-ft ofinfiltradon system: D=' 4 ft. Efate Of sails R= 42 inlhr i time: DDT= 1.14285714 hrs. % impervious = 0.769 = M.9% say 77.0% CPRE = 0,25 CPOST = (% imp.)(.95)+(1-% imp)(25) 0.79 110 = 7.23 in/hr 125 = 8.T5 in/hr 01141 CDC WATERSHED DATA Total Drainage Area fk acres 13,905 0.32 CITY BLC= Infiltration Trench E 10-year Storm lm rvious Area Land Use sq. ft. acres NAdWA it 5,390 0.12 5,469 0.13 concrete 1,421 0.03 Total 12,280 0.28 Volume of first inch of runoff = (impervious area)1112 V= 1,023.33 cu-ft Volume of pipe provided= Area x Length Vpipe24"= 298.00 cu-ft Volume of trench provided= (LxMD) - total pipe volume Vtp= 3,502.00 cu-ft 'Storage volume provided= (Vip ' 0.40) + total pipe volume Vp- 1, 69eJX)r ccr ft- DRAWDOWN TIME: Depth of inhltradon system: D= 4 ft. laftration Rate at sails R= 42 inlhr Drawdown time: DDT= 1.14285714 hrs. % impervious = 0.883 = 88.3% say 89.0% CPRE = 0.25 CPOST = (% imp.)(.95)+(1-% imp.)(.25) 0.87 110 = 7.23 inihr 125 = 8.15 inihr 01141 TRIP ENGINEERING, P.C. 419 Chestnut Street Wilmington, North Carolina 28401 Phone: (910) 763-5 100 • FA1Y: (910) 763-5631 LETTER OF TRANSMITTAL To: Attention: - c:) Zi C::- Subject: FAX TRANSM77AL: NUMBER OF PAGES INCLUDES COVER I am sending you: ( ) Al i ACHED ( ) UNDER SEPARATE COVER ( ) Prints ( ) Tracings ( ) Copy of letter ( ) Specifications ( ) Other Copies Item No. Description These are transmitted as checked below: ( ) For Approval ( ) For Your Use ( ) Sign & Return ( ) Review Remarks: 1 C�� ``J 1 �� ---) is cc: Sign ���(! 0 TRIPP ENGINEERING, P.C. 419 Chestnut Street Wilmington, North Carolina 28401 Phone: (910) 763-5100 + FAX: (910) 763-5631 May 2, 2002 NCDENR Division Water Quality 127 Cardinal Drive Wilmington, NC 28405-3845 Attn: Ms. Linda Lewis Re: City Block New Hanover County, NC TE 01141 Dear Linda: FIVE MAY 0. 3 2002 Enclosed please find two (2) sets of plans, one (1) signed original and one (1) copy of the application form with narrative, four (4) underground infiltration trench supplements, two (2) sets of calculations, a soils report, and one check for the application fee. Please review for approval and contact us with any questions, comments or if you need additional information. Thank you. Sincerely, Tripp Engineering, P.C. Charles D. Cazier, E.I. A1000Rol Enc. `R . May 2, 2002 Stormwater Narrative City Block New Hanover County, NC TE 01141 City Block is a 1.92 acre commercial tract within the City of Wilmington's central business district. The site is an old junkyard, which has been cleaned up for redevelopment primarily as commercial with some condominium style residential units. The 1.92 acre tract, when built out, will have 32,301 sf of buildings, 21,875 sf for a parking deck facility and 17,673 sf of sidewalks and pedestrian access. Runoff from proposed impervious areas will be treated by various underground infiltration systems. Each system is designed to treat both the State's 1" requirement as well as the City's 10-year pre -post requirement. Outflow from the proposed systems will discharge to the Cape Fear River, classification C-SW.