Loading...
HomeMy WebLinkAboutWQ0038060_Application (FTSE)_20210407Permit Number WQ0038060 Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer dean.hunkele Coastal SWRuIe Permitted Flow 204,667 Facility Facility Name RiverLights Development Sewer Location Address Owner Owner Name Cape Fear Public Utility Authority Dates/Events Central Files: APS _ SWP _ 3/16/2021 Permit Tracking Slip Status Project Type In review Major modification Version Permit Classification L Individual Permit Contact Affiliation Major/Minor Region Minor Wilmington County New Hanover Facility Contact Affiliation Owner Type Government - Municipal Owner Affiliation James R. Flechtner PE 235 Government Center Or NC 28403 Scheduled �LyAl 11 �- /— a-1 Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration ® v� MCIQM&CREED March 11, 2021 Mr. Dean Hunkele NC Department of Environmental Quality - Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, NC 28405 RE: Fast Track Sewer Permit Modification - River Lights Development Pump Station No. 1 Permit No. WQ0038060 Cape Fear Public Utility Authority New Hanover County Dear Mr. Hunkele: ENGINE=NS 5U R V E YO R5 P L A N N E R 5 M&C 2735-0241 (40) CEN lW7 r- PAR 15 2021 On behalf of Cape Fear Public Utility Authority (CFPUA), we are pleased to submit this permit modification application for RiverLights Pump Station No. 1. The purpose of this modification is to increase the permitted firm capacity of RiverLights Pump Station No. 1 from 1.46 MGD to 2.88 MGD. Please find the following documentation enclosed: • One (1) hard and One (1) digital copy of application form • One (1) hard and One (1) digital copy of 8.5 x 11 color USGS Topographic map • One (1) hard and One (1) digital copy of 8.5 x 11 street map • One (1) hard and One (1) digital copy of Project Narrative • One (1) hard and One (1) digital copy of the existing permit approval letter • $480 check (permit fee) Please let me know if you have questions or would like to discuss. Thanks for your assistance on this project. Sincerely, McKIM & CREED, INC. Sean Kenyon, PE 243 N�-,rIh Fonr 5r,ec, w 1l n, i rig I o n, NC 28401 910 343 1048 Fax 910, 251.8282 1: \ 02735 \ 0241 \ 40-Permit \ FTS w.�.v.nukimueed com DWR Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources I;A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Cape Fear Public Utility Authority (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ® Municipal ❑ Other 3. Signature authority's name: Jeff Theberee per 15A NCAC 02T .0106(b) Title: Engineering Manager 4. Applicant's mailing address: 235 Government Center Drive City: Wilmington 5. Applicant's contact information: State: NC Zip: 28403-_ Phone number: (9) N2-6550 Email Address: Jeff Theberge (iDcfpua.org If. PROJECT INFORMATION: I. Project name: RiverLights Pump Station No.1 2. Application/Project status: ❑ Proposed (New Permit) ® Existing Pennit/Project If a modification, provide the existing permit number: W00038060 and issued date: Marc 6 If new construction but part of a master plan, provide the existing pennit number: WQ 3. County where project is located: New Hanover 4. Approximate Coordinates (Decimal Degrees): Latitude: 34.1450' Longitude:-77.9378° 5. Parcel ID (if applicable): R07000-006-309-000 (or Parcel ID to closest downstream sewer) Ill. CONSULTANT INFORMATION: I. Professional Engineer: Sean Kenyon, PE License Number: 049225 Finn: McKim & Creed. Inc Mailing address: 243 N. Front St. City: Wilmington State: NC Zip: 28401 Phone number: (910) 343-1048 Email Address: SKenyonCamckimcreed.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: I. Facility Name: M'Kean Maffitt (Southside) Wastewater Treatment Plant (SSW WTP) Owner Name: Cape Fear Public Utility Authority V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ Downstream (Receiving) Sewer Size: _ inch System Wide Collection System Permit Number(s) (if applicable): WQCS Owner Name(s): Permit Number: NCO023973 FORM: FTA 04-16 Page 1 of 5 V►. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes [-]No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes [-]No ®N/A 3. If the Applicant is a Home/Property Owners' Association has an Operational Agreement (FORM: HOA) been attached? ❑ Yes ❑No ®N/A 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5, Nature of wastewater : % Domestic/Commercial % Commercial Industrial (See 15A NCAC 02T .0103(20)) "Is there a Pretreatment Program in effect? ❑ Yes ® No 6. Hasa flow reduction been approved under 15A NCAC 02T .0114(t)? ❑ Yes ®No ➢ If yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see O2T.0114(f1) Daily Design Flow a,b No. of Units Flow gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 0 GPD a See 15A NCAC 02T .01 14(b), (d), (el( I ) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .01 14(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01 141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 0 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ® Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VIL GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T.0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material ➢ Section 11 & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC Vlll. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: RiverLights Pump Station No.1 2. Approximate Coordinates (Decimal Degrees): Latitude: 34.1450' Longitude:-77.9378° 3. Design flow of the pump station: 2.88 millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): 2000 gallons per minute at 126 feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material N/A N/A N/A 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ® Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B): ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T.0305(f)): Does the project comply with all separations found in 15A NCAC 02T .0305(n & (eg ® Yes [-]No ➢ 15A NCAC 02T.0305(n contains minimum senarations that shall be nrovided for sewer systems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains vertical -water over sewer including in benched trenches 18 inches Water mains (horizontal) 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inches Reclaimed water lines horizontal - reclaimed over sewer 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SB from normal high water or tide elevation and wetlands see item IX.2 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top sloe of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ 15A NCAC 02T.0305(u) contains alternatives where separations in 02T.0305(f) cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage ➢ If noncompliance with 02T.0305(f) or (e), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) []Yes []No ® N/A ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No ® N/A ➢ This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ❑ Yes ® No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer Permittine Branch 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional pennits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No ❑ N/A ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Desien Criteria (latest version) as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents 2. Professional Engineer's Certification: Sean Kenyon attest that this application for (Professional Engineer's name from Application Item 111.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T .0I06(b): Jeff Theberge, Enc Ma (Signature Authority's name & title from Application Item �OQ�.FESgjO.(�,G a SEAL 7 , - '04 .25. 7Lt/It that this application for has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: _ (mil /Yf¢2�2 Date: 3/10/2021 FORM: FTA 04-16 Page 5 of 5 vIMCIQM&CREED PROJECT DESIGN NARRATIVE TO: Cape Fear Public Utility Authority FROM: Sean Kenyon, PE DATE: February 18, 2021 RE: River Lights Pump Station No. 1 Permit Modification — WQ0038060 River Lights Development M&C#: 02735-0241 I. Background Newland Communities currently has a Developer Agreement in place that provides for the construction of two (2) pump stations to serve the proposed RiverLights subdivision. Pump Station No. 1 (PS 1) has been constructed and permitted under Permit No. WQ0038060. Pump Station No. 2 is scheduled to begin construction by late 2021. Exhibit 1 provides a schematic of the recommended configuration with existing PS 1 and future PS 2. PS 1 was constructed in the northern portion of the River Lights community and discharges to the Southside WWTP via manifold connection to the Motts Creek PS 20-inch force main located along the re -aligned River Road. Proposed PS 2 is planned to be constructed in the southern portion of the River Lights community. The proposed force main leaving PS 2 shall generally follow the old River Road easement and discharge into an existing manhole outside of PS 1 to then be repumped by PS 1. RiverLights PS2 and associated force mains are permitted separately. To serve the buildout flow of the PS2 basin, a new pump will need to be installed within the RiverLights PS1 wet well to increase the existing firm capacity of this station (1.46 MGD). With the installation of an additional pump, the firm capacity of the station will increase to 2.88 MGD. The purpose of this memorandum is to detail the design approach, modeling results, and pump sizing recommendations for PS 1. 02735-0241 1 February 2021 River Lights PS No. 1 Il. Demands and Peak Hour Factors Demands for PS 1 have been developed based on the development plans for the RiverLights community. The average daily flow to be served by PS 1 is as follows: • Average Daily Flow (ADF) = 889,711 GPD Additionally, as required by NCDEQ Minimum Design Criteria, peak hour factors were calculated based on Residential Equivalent Units (REU) to be constructed within the station service area. The NCDEQ formula as shown below was utilized in this calculation. Peaking Factor Calculation Service Area Population = P Peak Factor = 18 + 4P 4+4P The peaking factor used in the pump station design is as follows: • Peak Hour Factor (PHF) = 3.08 III. Pump Sizing Based on the average daily flows and PHF's the peak pump rate for PS 1 is provided below: Average Daily Minimum Peak Design Pumping Demand (GPD) Peaking Factor Pump Rate (GPM) Rate (GPM) 889,711 3.08 1904 2000 RiverLights Pump Station 1 currently operates as a duplex pump station with two (2) 60 HP pumps with 12-inch impellers. One pump operates as a standby. There is an extra pump slot within the wet well for a new pump to be installed. Hydraulic modeling was conducted to determine the operating condition of the upgraded pump station with the addition of the third pump. Note that the hydraulic modeling results assume that all manifold pump stations are on, since that is the most conservative scenario. Hydraulic results are as follows: 02735-0241 2 February 2021 River Lights PS No. 1 Flow (GPM) Pump Head (FT) 0 85.7 500 92.1 1000 101.1 1500 112.5 2000 126.0 2500 141.6 3000 159.1 3500 178.7 4000 200.2 Based on the results, a triplex, Myers 4VC/4VCX configuration with 60 HP motors, and 12-inch impellers will meet the conditions. Note that the new pump to be added to the existing wet well is identical to the pumps that are already there. Find the recommended pump curve below: Pump Curve 200 ISO 160 140 120 �y 100 w BO 60 40 20 0 \ ff�69 72 8.00 in In hp 0 200 400 600 S00 1,000 1200 Flow - USgpm Minim= Continua Stable Flom Prefwed opentins sion ` 72 C 69 ` 3Q Ohp 40 0 hp 1 30 J hp 2.0 hp 20.0 hp 1,400 1,600 1,S00 2,000 02735-0241 3 February 2021 River Lights PS No. 1 IV. Summary The recommend configuration of the upgraded RiverLights PS No. 1 is summarized in the following table. The addition of the new pump will increase the capacity of the pump station from its current permitted firm capacity of 1.46 MGD to 2.88 MGD and shall serve the new flows conveyed by RiverLights Pump Station No. 2, when it is constructed. Pump Station ADF Station Pump Pump (GPD) Configuration Rate TDH Selection HP RPM (GPM) Myers 889,711 Triplex 2,000 126 4VC/4VCX 60 1750 12-Inch Impeller END OF MEMORANDUM 02735-0241 4 February 2021 River Lights PS No. 1 EXHIBIT A �'1[a/R(a US. DEPARTMENT OFTNE INTERIOR yh NILMINGTONQRVAORANGLE dn4.J V.SGEOLOCICAL9L.RVEY u TooNORTH �snaxurE senlM a 4 I S I wwM M �w L w.n r 4 ,• r r � t e F4 I u t t n8e I � ... r p NILMINGTON _ a EvktingP 118118 _ SN,ll,4e.TP aMfi FN-Mene f •(r 9 EakIM9 RamaM.a f ) Cmek P il' " LELAND In Ezu, 1aa1le113 E"sting Motls Creek aM 8'Farce Ma ns 30 Force Man EusMgrtM CI k f. PumP EU o W G.•_bn j - —._ `It Ealsllno RHer �••. J - — e — LIBMe RE ` 9 _... _ - �-. vrov�•oe Rlver m Forc. Maln ugn�vs: �. n,, . n 5 ,....... g PmpeuE R. LYT81a P8T m - as f 1e u t + S ._. :•- is ra w •.mp,yw TI scuE 1'Ee 0.0 wun n, •..onvya... .... ..w•�m.. s.v• W LMINGTON,NC Si v.e�'_ake .tea +�/ \•CJD / i 4 vr.0 -1 Y 3 Jrv`i• & O- �i •�� 'sue .;4. °: - Q� l MsPROPOSED 10" FORCE MAIN o�e�c� 0 x m \ f -.Rile ghts-PS 2 j �� Imagery Date: 2i5/2019 34°08'29.56"