HomeMy WebLinkAboutWI0300162_Staff Report_20210401Date: 31 March 2021 To: Shristi Shrestha_ Central Office Reviewer Permit No. WI0300162 County: Iredell Permittee/Applicant: Barile Residence Facility Name: John and Virginia Barile I. GENERAL INFORMATION 1. This application is (check all that apply): ❑ New ® Renewal ❑ Minor Modification _ Major Modification a. Date of Inspection: 03-30-2021 b. Person contacted and contact information: John Barile (704) 546-7900 c. Site visit conducted by: Edward Watson and Maria Schutte d. Inspection Report Printed from BIMS attached: ® Yes ❑ No. The inspection can also be found in BIMS, when sample results are received from the lab the inspection report and results will be sent to the permittee. e. Physical Address of Site including zip code: 200 Countryside Rd., Harmony, NC 28634 f. Driving Directions if rural site and/or no physical address: g. Latitude:35.989504 Longitude: -80.769271 Source of Lat./Long & Accuracy (i.e., Google Earth, GPS, etc.): GCS WGS 1984 to nearest 10 seconds. IL DESCRIPTION OF INJECTION WELL(S) AND FACILITY 1. Type of injection system: ® Geothermal Heating/Cooling Water Return ❑ In situ Groundwater Remediation ❑ Non -Discharge Groundwater Remediation Other (Specify: 2. For Geothermal Water Return Well(s) only a. For existing geothermal system only: Were samples collected from Influent/Effluent sampling ports? ® Yes ❑ No. Provide well construction information from well tag: Well construction information on file, indicates the well was installed 8/18/2010 to a total depth on 645 ft. BLS. The well is 6" diameter has 110 ft. of casing. The well yield is 8GPM and static water level is 60 ft. BLS. The tag was not readable on the site visit on 3-30-21. b. Does existing or proposed system use same well for water source and injection? ® Yes ❑ No If No, please provide source/supply well construction info (i.e., depth, date drilled, well contractor, etc.) and attached map and sketch location of supply well in relation to injection well and any other features in Section IV of this Staff Report. 3. Are there any potential sources that may affect injection? n Yes ® No What is/are the source(s)? NA 4. Quality of drainage at site: ® Good ❑ Adequate ❑ Poor 5. Flooding potential of site: ® Low ❑ Moderate ❑ High 6. Does the map included in the Application reasonably represent the actual site (property lines, wells, surface drainage)? ® Yes ❑ No. If No, or no map, please attach a sketch of the site. Show property boundaries, buildings, wells, potential pollution sources, roads, approximate scale, and north arrow. III. EVALUATION AND RECOMMENDATIONS 1. Do you foresee any problems with issuance/renewal of this permit? ❑ Yes ® No. If Yes, explain. 2. List any items that you would like WQROS Central Office to obtain through an additional information request. Make sure that you provide a reason for each item: Item Reason 3. List specific special conditions or compliance schedules that you recommend to be included in the permit when issued. Make sure that you provide a reason for each special condition: Condition Reason 4. Recommendation n Deny. If Deny, please state reasons: n Hold pending receipt and review of additional information by Regional Office n Issue upon receipt of needed additional information ® Issue 5. Signature of Report Preparer(s): Edward Watson 3-31-2021 • —DocuSigned by: A444444, N P444 • F161 FB69A2D84A3... 4.1.21 Signature of WQROS Regional Supervisor: Date: IV ADDITIONAL REGIONAL STAFF REVIEW COMMENTS/ATTACHMENTS (Optional /If Needed) Water samples were collected from the Influent and Effluent ports of the geothermal well. The water samples were submitted to the DWQ Water Quality lab for analysis. Samples will be analyzed for a variety of parameters. The laboratory was notified of parameters with short hold times such as Total and Fecal Coliform bacteria and Total Nitrate as (NO3 + No2-N). Laboratory reports will follow once all of the analysis have been completed. If elevated constituents are discovered by the sample analysis, the permittee will be notified regarding corrective actions that may need to be taken to correct elevated constituent reported from the lab analysis. The MRO recommends the renewal of this permit.