Loading...
HomeMy WebLinkAboutWI0500481_GEO THERMAL_20120523Beverly Eaves Perdue Governor NA NC DE ~R North·Carolina Department of Environment and NaturaLRes_ources Division of Water Quality Charles Wakild, P. E. Director May 23, 2012 Ashley Pessagno 235 Buck Branch Road Pittsboro, NC 27312 Subject: Notification of Rule Revisions Affecting Closed-Loop Geotherm~ Injection Well Permit Holders Permit Number: WI0500481 Dear Ms. Pessagno: Dee Freeman Secretary Our records indicate that you currently hold a permit for a closed-loop geothermal injection well system. This letter is to inform you that on May 1, 2012, the North Carolina Administrative Code Title 15A Section 2C .0200 entitled "Well Construction Standards -Criteria and Standards Applicable Injection Wells" were revised. These revisions affect all permits issued for injection wells including geothermal wells. This letter is also to inform you that your closed-loop geothermal injection well(s) have become "permitted by rule." Therefore, you are no longer required to renew your current permit and the permit will be valid indefinitely as long as the wells are active and are operated in accordance with the revised rules referenced above. Please keep in mind that if you abandon the wells, a record of abandonment must be submitted to the Division of Water Quality. You may view the revised rules on our website at http ://portal.ncdenr.org/web/wq /ap s. If you have any. questions reg~_ding your cunent permit or ~he fl:lle revisions, ple_ase. feel free to contact our underground injection control staff at (919) 807-6464. Sincerely, Eric G. Smith, P.G. Hydrogeologist cc: UIC Pennit File AQUIFER PROTECTION SECTION 1636 Mail Service Center, Raleigh, North Carolina 27699-1636 Location: 512 N. Salisbury St, Raleigh, North Carolina 27604 Phone: 919-807-6464 I FAX: 919-807-6496 Internet: www.ncwaterquality.org An ~qual Opporlunily \ Af.irmative Action Employer Nirth Carolina ;Vatura!l11 Permit Number W10500481 Central Files: APS SWP 03/13/12 Permit Tracking Slip Program Category Ground Water Permit Type Injection Mixed Fluid GSHP Well System (5QM) Status Project Type Active New Project Version Permit Classification 1.00 Individual Primary Reviewer Permit Contact Affiliation eric.g.smith Coastal SW Rule Permitted Flow Facility Facility Name Ashley Pessagno SFR Location Address 235 Buck Branch Rd Pittsboro Owner Owner Name Major/Minor Region Minor Raleigh County Chatham NC 27312 Facility Contact Affiliation Owner Type Individual Ashley Pessagno Owner Affiliation Ashley Pessagno Elates/Events Orig Issue App Received Draft initiated 03/02/12 02/14/12 Regulated Activities Heat Pump Injection Outfall NULL Scheduled issuance PO Box 1302 Pittsboro NC 27312 Public Notice Issue Effective Expiration 03/02/12 03/02/12 02/28/17 Re:'uestedlReceived Events RO staff report requested 02/16/12 RO staff report received 02/28/12 Waterbody Name Stream Index Number Current Class Subbasin L-- NCDENR North Carolina department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Charles Wakild, P.E. Dee Freeman Governor Director Secretary March 2, 2012 Ashley Pessagno Post Office Box 1302 Pittsboro, NC 27312 Ref: Issuance of Injection Well Permits WI0500481 Issued to Ashley Pessagno Pittsboro, Chatham County, North Carolina Dear Mr. Pessagno: In accordance with the application received on February 14, 2012, I am forwarding permit number WI0500481 for the construction and operation of a vertical closed -loop geothermal mixed -fluid heat pump injection well system to be located at 235 Buck Branch Road, Pittsboro, Chatham County, NC 27312. This permit shall be effective from the date of issuance until February 28, 2017, and shall be subject to the conditions and limitations stated therein, including the requirement to install well identification tags as specified in Part II. Be sure to read the entire permit to ensure that you are aware of all compliance requirements of the permit. You will need to notify this office at least 48 hours prior to beginning construction and operation of the injection well system. In order to continue uninterrupted legal use of the injection facility for the stated purpose, you must submit an application to renew the permit 120 days prior to its expiration date. This permit is not transferable to any person without prior notice to and approval by the Director of the Division of Water Quality. Please contact me at (919) 807-6407 or eric.g.smithialncdenr.Yov if you have any questions about your permit. Best Regards, Eric G. Smith, F.G. cc: Jay Zimmerman, Raleigh Regional Office W1050048 I Permit File Chatham County Environmental Health Department James Darby, Jr.; James Darby Well Drilling, LLC; 2512 Zinker Road, Rock Hill, SC 29732 AQUIFER PROTECTION SECTION 1636 Mail Service Center. Raleigh, North Carolina 27699-1636 Location; 512 N. Salisbury St, Raleigh, North Carolina 27604 Phone: 919-807-6464 I FAX; 919.807.6496 Internet: www.n terq &lity.org An 'alai; Opportunity 1 Affirmative khan Employer Non5aturaUj thCarolina NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH, NORTH CAROLINA PERMIT FOR THE CONSTRUCTION AND OPERATION OF A WELL FOR INJECTION In accordance with the provisions of Article 7, Chapter 87; Article 21, Chapter 143; and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Ashley Pessagno FOR THE CONSTRUCTION AND OPERATION OF 3 (THREE) TYPE 5QM INJECTION WELL(S), defined in Title 15A North Carolina Administrative Code 2C .0209(e)(3)(F), for the purpose of operating a vertical closed loop geothermal mixed fluid heat pump system. This system is located at 235 Buck Branch Road, Pittsboro, Chatham County, NC 27312, and will be constructed and operated in accordance with the application received February 14, 2012, and in conformity with the specifications and supporting data submitted, all of which are filed with the Department of Environment and Natural Resources and are considered a part of this permit. This permit is for Construction and Operation of an injection well and shall be in compliance with Title 15A of the North Carolina Administrative Code 2C .0100 and .0200 plus any other applicable Laws, Rules, and Regulations pertaining to well construction and use. This permit shall be effective, unless revoked, from the date of its issuance until February 28, 2017, and shall be subject to the specified conditions and limitations set forth in Parts I through IX hereof. Permit issued this the 2'd day of March, 2012. klCharles Wakild, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission. Permit #W10500481 UIC/5QM ver. 03/2Qi0 Page 1 of 5 PART I -WELL CONSTRUCTION GENERAL CONDITIONS 1. The Peimittee must comply with all conditions of this permit and with the standards and criteria specified in Criteria and Standards Applicable to Injection Wells (15A NCAC 2C .0200). Any noncompliance with conditions of this permit constitutes a violation of the North Carolina Well Construction Act and is grounds for enforcement action as provided for in N.C.G.S. 87-94. 2. This permit shall become voidable unless the facility is constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 3. Each injection well shall not hydraulically connect separate aquifers. 4. Each injection well shall not be located in an area generally subject to flooding. Areas that are generally subject to flooding include those with concave slope, alluvial or colluvial soils, gullies, depressions, and drainage ways. 5. Each injection well shall be afforded reasonable }lrotection against damage during construction and use. PART II -WELL CONSTRUCTION SPECIAL CONDITIONS 1. At . least forty-eight ( 48) hours prior to constructing system, the Permittee shall notify the Aquifer Protection Section's Underground Injection Control (UIC) Program Central Office staff, telephone number 919-807-6406 and the Raleigh Regional Office Aquifer Protection Section Staff, telephone number 919-791-4200. 2. The location of each of the system manifolds shall be recorded by triangulation from three permanent features on the site (e.g., building foundation comers) and shown on an updated Site Map. The Permittee shall retain a copy of this record on site. 3. One well identification tag per grouping or 'cluster' of wells shall be permanently affixed to the heating and cooling unit or other nearby permanently fixed location in accordance with ISA NCAC 2C .0213(g). PART III-OPERATION AND USE GENERAL CONDITIONS 1. This permit is effective only with respect to the nature, volume of materials and rate of injection, as described in the application and other supporting data. 2. This permit is not transferable without prior notice to, and approval by, the Director of the Division of Water Quality (Director). In the event there is a desire for the facility to change ownership, or there is a name change of the Permittee, a formal pem1it amendment request must be submitted to the Director, including any supporting materials as may be appropriate, at least 30 days prior to the date of the change. 3 . The issuance of this permit shall not relieve the Permittee of the responsibility of complying with any and all statutes, rules, regulations, or ordinances , which may be imposed by other local, state, and federal agencies, which have jurisdiction. Furthermore, the issuance of this permit does not imply that all regulatory requirements have been met. Permit #WI0500481 UIC/SQM ver . 03/2010 Page 2 of 5 ••'•?-'.•"'· . ..-~·~:-: ·•;,?'~ ."f ,. ~-,.·~:::~··.*~--~·'·~.~~":,,,"·":',":·:1·:·· · ... , ... . t PART IV-PERFORMANCE STANDARDS 1. The injection facility shall be effectively maintained and operated at all times so that there is no contamination of groundwater that will render it unsatisfactory for normal use. In the event that the facility fails to perform satisfactorily, including the creation of nuisance conditions or failure of the injection zone to adequately assimilate the injected fluid, the Pennittee shall take immediate corrective actions including those actions that may be required by the Division of Water Quality such as the repair, modification, or abandonment of the injection facility. 2. The Permittee shall be required to comply with the terms and conditions of this permit even if compliance requires a reduction or elimination of the permitted activity. 3. The issuance of this permit shall not relieve the Permittee of the responsibility for damages to surface or ground water resulting from the operation of this facility. PART V -OPERATION AND MAINTENANCE REQUIREMENTS 1. The injection facility shall be properly maintained and operated at all times. 2. The Permittee must notify the Division and receive prior written approval from the Director of any planned physical alterations or additions in the permitted facility or activity not specifically authorized by the permit. · 3. At least forty~eight ( 48) hours prior to the initiation of the operation of the facility for injection, the Permittee must notify by telephone the Aquifer Protection Section's Underground Injection Control (UIC) Program Central Office staff, telephone number 919-807~6406. Notification is required so that Division staff can inspect or otherwise review the injection facility and determine ifit is in compliance with permit conditions. PART VI -INSPECTIONS 1. Any duly authorized officer, employee, or representative of the Division of Water Quality may, upon presentation of credentials, eriter and inspect any property, premises, or place on or related to the injection facility at any reasonable time for the purpose of determining compliance with this permit, may inspect or copy any records that must be maintained under the terms and conditions of this permit, and may obtain samples of groundwater, surface water, or injection fluids. 2. Division representatives shall have reasonable access for purposes of inspection, observation, and sampling associated with injection and any related facilities as provided for in N.C.G.S. 87-90. 3. Provisions shall be made for collecting any necessary and appropriate samples associated with the injection facility activities; Permit #WI0500481 UIC/SQM ver. 03/2010 Page 3 of 5 PART VII — MONITORING AND REPORTING REQUIREMENTS All required documentation shall be submitted to: Aquifer Protection Section — UIC Program DENR — Division of Water Quality 1636 Mail Service Center Raleigh, NC 27699-1636 Ph# 919-715-3221 and Aquifer Protection Section Raleigh Regional Office 3800 Barrett Drive Raleigh, NC 27609 919-791-4200 2. A completed Well Construction Record (Form GW-1) for each injection well must be submitted to the Aquifer Protection Section Central Office and the Raleigh Regional Office within 30 days of completion of well construction. Copies of the GW-1 form(s) shall also be given to the Permittee and retained on site to be made available for inspection. 3. A copy of the site map updated with manifold locations required in Part 11.2 of this permit shall be submitted to the Aquifer Protection Section Central Office and the Raleigh Regional Office within 30 days of completion of well construction. 4. Any monitoring (including groundwater, surface water, or soil sampling) deemed necessary by the Division of Water Quality to insure surface and ground water protection will be established and an acceptable sampling reporting schedule shall be followed, 5. The Permittee shall report by telephone, within 48 hours of the occurrence or first knowledge of the occurrence, to the Raleigh Regional Office, telephone number 919-791-4200, any of the following; (A) (B) (C) (D) Any occurrence at the injection facility that results in any unusual operating circumstances; Any failure due to known or unknown reasons that renders the facility incapable of proper injection operations, such as mechanical or electrical failures; Any loss of refrigerant in the system, regardless of the origin of the loss; Any recharging of the refrigerant system. 6. Where the Permittee becomes aware of an omission of any relevant facts in a permit application, or of any incorrect information submitted in said application or in any report to the Director, the relevant and correct facts or information shall be promptly submitted to the Director by the Permittee. 7. In the event that the permitted facility fails to perform satisfactorily, the Permittee shall take such immediate action as may be required by the Director, PART VIII — PERMIT RENEWAL In order to continue uninterrupted legal use of the injection facility for the stated purpose, the Permittee shall submit an application to renew the permit 120 days prior to its expiration date. Permit #tWI0500481 U IC/5QM ver. 03/2010 Page 4 of 5 PART IX-CHANGE OF WELL STATUS 1. The Permittee shall provide written notification within 15 days of any change of status of an injection well. Such a change would include the discontinued use of a well for injection. If a well is taken completely out of service temporarily, the Permittee must install a sanitary seal. If a well is not to be used for any purpose, then that well must be permanently abandoned according to 15A NCAC 2C .0213(h)(l). Notification shall be submitted to the addresses given in Part VII.1 of this permit. 2. When operations have ceased at the facility and a well will no longer be used · for any purpose, the Permittee shall abandon that injection well in accordance with the procedures specified in ISA NCAC 2C .0214, including but not limited to, the following: (A) All casing and materials may be removed prior to initiation of abandonment procedures if the Director finds such removal will not be responsible for, or contribute to, the contamination of an underground source of drinking water. · (B) The entire depth of each well shall be sounded before it is sealed to insure freedom from obstructions that may interfere with sealing operations. (C) Each well shall be thoroughly disinfected, prior to sealing, if the Director determines that failure to do so could lead to the contamination of an underground source of drinking water. (D) Each well shall be completely filled with cement grout, which shall be introduced into the well through a pipe that extends to the bottom of the well and is raised as the well is filled. (E) In: the case of gravel-packed wells in which the casing and screens have not been removed, the casing shall be perforated opposite the gravel pack, at intervals not exceeding 10 feet, and grout injected through the perforations. (F) In those cases when, as a result of the injection operations, a subsurface cavity has been created, each well shall be abandoned in such a manner that will prevent the movement of fluids into or between underground sources of drinking water and in accordance with the terms and conditions of the permit. (G) The Permittee shall submit a copy of the Well Abandonment Record (Form GW-30) as specified in 15A NCAC 2C .0213(h)(l) within 30 days of completion of abandonment. Copies shall be submitted to the addresses given in Part VII. I of this permit. Permit #WI0S00481 UIC/SQM ver. 03/2010 Page 5 of 5 Smith, Eric From: Smith, Eric Sent: To: Monday, February 27, 2012 9:32 AM Mccartney, Lin Subject: RE: Geothermal Inspection for WI0500481 Un: Did you send over the site inspection report? -Eric G. Smith Eric G. Smith, P.G. Hyd rogeologist NCDENR Aquifer Protection Section Groundwater Protection Unit 1636 Mail Service Center Raleigh, NC 27699-1636 919-807-6407 919-807-6496 Fax http://portal.ncdenr.org/web/wq/aps DISCLAIMER: Per Executive Order No. 150, all e-mails sent to and from this account are subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Mccartney, Lin Sent: Monday, February 27, 2012 9:14 AM To: Smith, Eric Subject: RE: Geothermal Inspection for WIOS00481 Eric, Yes, l did the site inspection. Lin From: Smith, Eric Sent: Monday, February 27, 2012 8:46 AM To: Mccartney, Lin Subject: Geothermal Inspection for WI0500481 Lin: Have you performed the site inspection for geothermal permit WI0500481 (Pessangno)? -Eric G. Smith 1 Smith, Eric From: Zimmerman , Jay Sent: To: Thursday , February 16 , 2012 4 :47 PM Smith, Eric Subject: RE: WI0500481 5QM Application 1111 ask Un McCartn ey to conduct a pre-permit inspectio n and submit a staff report. From: Smith, Eric Sent: Thursday, February 16, 2012 1:S4 PM To: Zimmerman, Jay Subject: WIOS00481 SQM Application Jay: Since Mike Rogers is out for a few weeks, I'll be assisting with SQM permits. This is my first email of this type, so if you need anything else, let me know. Attached is a SQM application we received 2/14/12. Do you want to do a pre-permitting inspection? -Eric G. Smith Eric G. Smith, P.G. Hyd rogeo logist NCDENR Aquifer Protection Section Groundwater Protection Unit 1636 Mail Service Center Raleigh, NC 27699-1636 919-807-6407 919-807-6496 Fax http://portal.ncdenr.org/web/wq/aps DISCLAIMER: Per Executive Order No. 150, all e-mails sent to and from this account are subject to the North Carolina Public Records Law and may be disclosed to third parties. 1 41,4 MCDEMR North Carolina Department of Environment and Natural Resources Governor Ashley Pessangno PO Box 1302 Pittsboro, NC 27312 Dear Ms, Pessangii : Director Secretary February 14, 2012 Subject: Acknowledgement of Application No. W10500481 Ashley Pessangno SFR Injection Mixed Fluid GOP Well (5QM) System Chatham County The Aquifer Protection Section acknowledges receipt of your permit application and supporting documentation received on February 14, 2012. Your application package has been assigned the number listed above, and the primary reviewer is Michael Rogers. Central and Raleigh Regional Office staff will perform a detailed review of the provided application, and may contact you with a request for additional information. To ensure maximum efficiency in processing permit applications, the Aquifer Protection Section requests your assistance hi providing a timely and complete response to any additional information requests. Please note that processing standard review permit applications may take as long as 60 to 90 days after receipt of a complete application. If you have any questions, please contact Michael Rogers at (919) 807-6406 or michael.rogers[a7ncdenr.gov. Sincerely, for Debra J. Wat{s Groundwater Protection Unit Supervisor cc: Raleigh Regional Office, Aquifer Protection Section James Darby — James Darby Well Drilling, LLC Permit File W10500481 l i1v;- 1636 hda[I Service Center, Raleigh. North Carolina 27689.1636 Location: 512 N. Salisbury St., Raleigh, Norlh Carolina 27604 Phone: 919$e7.64641 FAX 919.8Q7.6496 Internet www.ncwaternua[Ity.org An Equal Opportunity 1 Affirmativs Action Employer 641 kJz One. NorthCarolina naturally NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES APPLICATION FOR A PERMIT TO CONSTRUCT OR OPERATE INJECTION WELLS In Accordance With the Provisions of 15A NCAC 02C .0200 CLOSED-LOOP MIXED-FLUID GEOTHERMAL INJECTION WELLS These wells circulate fluids other than potable water as part of a geothermal heating and cooling system (check one) _X_New Application Renewal* ---Modification * For renewals complete Parts A-C and the signature page. Print or Type Information and Mail to the Address on the Last Page. Illegible Applications Will Be Returned As Incomplete . DATE: 1/30 20 12 PERMIT No.~Q5Qn--f5/ (leave blank if New Application) '-) -q 1 J A. STATUS OF APPLICANT (choose one) Non-Government: Individual Residence X Business/Organization __ Government: State Municipal__ County__ Federal B. PERMIT APPLICANT -For individual residences, list each owner on property deed. For all others, state name of entity and name of person delegated authority to sign on behalf of the business or agency: Ashley Pessangno ______________________________ _ Mailing Address: PO Box 1302 __________________________ _ City: Pittsboro State: _NC_ Zip Code:27312 County: Chatham Day Tele No.: -----=9--=1~9--=-2~7-=-0--=-0"""1""'1=---5 -----------=C"""e=ll-=-N"""o'"".:'--_~S=am=e ______ _ EMAIL Address: __ ~A~s~h_le~y~f@._. . ._pc~e_a~ss~o~c1~·a~te~s _.c_o=m'-----------~F~ax~N~o~.: _____ _ · C. LOCATION OF WELL SITE -Where the injection wells are physically located: (I) Parcel Identification Number (PIN) of well site __ 2001-3 IO __ County: Chatham (2) Physical Address (if different than mailing address): ----=2=3=5--=B=u=c=k'----"B=r=a=nc=h=---R:..a.=d ______ _ City: Pittsboro State: NC Zip Code: ~2~73~1~2'----- D. WELL DRILLER INFORMATION Well Drilling Contractor's Name: __ __._J=am=es"-'D=ar=b--'--=--J=---r _________________ _ NC Well Drilling Contractor Certification No.: ---~2=6~0~6 _______________ _ Company Name: James Darbv Well Drilling LLC Contact Person."-: ---=J am=e=s"-'D==ar=b_,_v-=-J=---r ------=E=MA=-=cIL=cA~d=dr=e=ss"-'-: i=a=m'-"e""sd:::ar:e.b""-'--'w'-'-e=l~l@;;:,~!!=moo:a=il.:.::.cc.:a:co=m Address: ______ 2=5~1=2~Z=i=n=ke=r~R=d~----------------------- City: Rock Hill Zip Code: 29732 State: SC County: ___ Y~o=r=k'-- Office Tele No.: 803-329-2424 Cell No.: 803-415-1853 __ Fax No.: 803-329-4935 GPU/UIC 5QM Permit Application (Revised 1/24/2011) Page I E. HEAT PUMP CONTRACTOR INFORMATION (if different than driller) Company Name: __________________________________ _ Contact Person . .,_: -------'P'-'r,..,,o"'pc:,:e-'--'rt'-'-v....::O::..w.:..:..::n=er"--------------'E=MA==IL~A'--=-=d=d=-cre=s=s '-: ___________ _ Address: ___________________________________ _ City: Zip Code: ____ State: __ County: Office Tele No.: _________ Cell No.; __________ ~F=ax~N~o~.'-: _______ _ F. WELL CONSTRUCTION DATA (1) Number of borings to be constructed*: ___ 3 ___ Depth of each boring (feet): __ 335 ____ _ * If existing water supply wells will be used then provide the information in item (4) below. (2) Chemical additives to be used: R-22 __ _ Propylene glycol _x __ Ethanol __ _ Other _________ (other additives will need prior approval by NCDENR before use) (3) Type of tubing to be used (copper, PVC, etc): _HDPE Plastic (Black Pipe) ________ _ (4) Well casing. If the well(s) will use casing then provide the !Yill?, (steel, PVC, plastic, etc.), diameter, depth, and extent of casing appearing above ground: __ NIA __ (5) Grout (material surrounding well casing and/or piping): (a) Grout type: Cement__ Bentonite** _x_ Other (specify) _______ _ ** By selecting bentonite·grout, a variance is hereby requested to 15A NCAC 2C .0213(d)(l)(A), which requires a cement type grout. (b) Grout depth of tubing (reference to land surface): from _O __ to _335 __ (feet) If well has casing, indicate grout depth: from _O __ to __ 335 __ (feet) G. WELL LOCATIONS -Maps must be scaled or otherwise accurately indicate distances and orientations of features located within 1000 feet of the injection well(s). Label all features clearl v and include a north arrow. (I) Attach a site-specific map showing the locations of the following: * Proposed injection wells * Buildings * Property boundaries * Surface water bodies * Water supply wells * Septic tanks and associated spray irrigation sites, drain fields, or repair areas * Existing or potential sources of groundwater contamination (2) Attach a topographic map of the area extending 1/4 mile from the injection well site that indicates the facility's location and the map name. NOTE: In most cases, an aerial photograph of the property parcel showing property lines and structures can be obtained and downloaded from the applicable county GIS website. Typically, the property can be searched by owner name or address. The location of the wells in relation to property boundaries, houses, septic tanks, other wells, etc. can then be drawn in by hand. Also, a 'layer' can be selected showing topographic contours or elevation data. GPU/UIC 5QM Permit Application (Revised 1/24/201 I) Page 2 H. CERTIFICATION (to be signed as required below or by that person's authorized agent) 15A NCAC 02C .02ll(b) requires that all permit applications shall be signed as follows: 1. for a corporation: by a responsible corporate officer; 2. for a partnership or sole proprietorship: by a general partner or the proprietor, respectively; 3 . for a municipality or a state, federal, or other public agency: by either a principal executive officer or ranking publicly elected official; 4. for all others: by the well owner (which means all persons listed on the pro pe rtv deed). If an authorized agent is signing on behalf of the applicant, then supply a letter signed by the applicant that names and authorizes their agent to sign this application on their behalf. "I hereby certify, under penalty of law , that I have personally examined and am familiar with the information submitted in this document and all attachments thereto and that, based on my inquiry of those individuals immediately responsible for obtaining said information, I believe that the information is true, accurate and complete. I am aware that there are significant penalties, including the possibility of fines and imprisonment, for submitting false information. I agree to construct, operate, maintain, repair, and if applicable, abandon the injection well and all related appurtenances in accordance with the approved specifications and conditions of the Permit" ~ /47, _ Si gnatureof.perty Owner/;e pplicant _Ashley Pessagno --------------- Print or Type Full Name Signature of Property Owner/Applicant Print or Type Full Name Signature of Authorized Agent, if any Print or Type Full Name Submit two copies of the completed application package to: DWQ -Aquifer Protection Section 1636 Mail Service Center Raleigh, NC 27699-1636 Telephone (919) 733-3221 GPU /UIC SQM Permit Application (Revised 1/24/2011) Page3 3 4 -za (4 f \1.ti► e n IIf t7 -,.... j'A'‘i;i1 \\ 1 i LI -31 ly gvi G� CHATHAM COUNTY. NC , Property Map n_ J° er The data provided on Ina: snap am prepared 4N1M Inventory el Ma: piopeily lov,d vif111•1 Chatham County, NC and lee complied horn recorded pfatn. deeds, and other pooiic recwd6 and data 'Madera Le rer nrarma1m4 purpnges only a-4 should not ee,ubttiluted faro eve Oa neg.!). ,moper:y app:aWar, surVoy, or or !ontng vafiFtatcn. PESSA AI t-I4E See f4�,,•/1 Cf'►tib k) TR-1 One inch =149 Fee! A7A NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director Secretary February 23, 2012 MEMORANDUM To: Michael Rogers, The Central Office, APS Through: Jay Zimmerman From: Lin McCartney Subject: Staff Report for Ashley Pessangno, W10500481, Chatham County Aquifer Protection Section 1628 Mail Service Center, Raleigh, North Carolina 27699-1628 Location: 3800 Sairett Dr., Raleigh,, North Carolina 27609 Phone: 919-79 i-42001 FAX: 919-571-47 18 1 Customer Service: I-g77-623-6748 Inien,et: www.ncwaterquality.ora An Equal Opportunity 1 Affirmative Action Employer NorthCarolina Naturally AQUIFER PROTECTION REGIONAL STAFF REPORT Date: Februarv 22 , 2012 To: A quifer Protection Central Office Central Office Reviewer: Michael Ro gers Regional Login No: __ _ County: Chatham Permittee: Ashley Pessangno Project Name: SQM Injection Well Application No.: WI0500481 L GENERAL INFORMATION 1. This application is (check all that apply): ~ New D Renewal D Minor Modification D Major Modification D Surface Irrigation D Reuse D Recycle D High Rate Infiltration D Evaporation/Infiltration Lagoon D Land Application of Residuals D Distribution of Residuals D Attachment B included D Surface Disposal D 503 regulated D 503 exempt D Closed-loop Groundwater Remediation ~ Other Injection Wells (including in situ remediation) Was a site visit conducted in order to prepare this report? ~ Yes or D No. a. Date of site visit: 11-07-2011 r \ N b. Person contacted and contact information: Ashle y Pessan gn o , 919-270-0115 ,",.) c. Site visit conducted by: Lin McCartne y -.J d. Inspection Report Attached:~ Yes or D No. .... (,.>,:, 2. Is the following information entered into the BIMS record for this application correct? • . .J ,. -} P1' yl C"), i C ~..._ er r • C • ~ Yes or D No. If no, please complete the following or indicate that it is correct on the current application. For Treatment Facilities: a. Location: b. Driving Directions: c. USGS Quadrangle Map name and number: __ d. Latitude: Longitude: __ e. Regulated Activities/ Type of Wastes (e.g., subdivision, food processing, municipal wastewater): __ For Disposal and Injection Sites: (If multi ple sites either indicate which sites the information a pp lies to . co py and paste a new section into the document for each site . or attach additional pa ges for each site) a. Location(s): 235 Buck Branch Road , Pittsboro . NC 27312 b. Driving Directions: Take US-1 S for 11.6 miles . merge onto US-64 W via 98B toward Pittsboro for 22 miles . merge US-15 N/US-501 N via Exit 383 for 4 miles , turn left Hamlets Chapel Rd., Tum ri ght onto Buck Branch. c. USGS Quadrangle Map name and number: NI A d. Latitude: 35-48-17 Longitude: 79-07-44 e. II. NEW AND MAJOR MODIFICATION APPLICATIONS (this section not needed for renewals or minor modifications, skip to next section) Description Of Waste(S) And Facilities 1. Please attach completed rating sheet. Facility Classification: __ FORM: Staff.Report-Ashley Pessangno-2 1 AQUIFER PROTECTION REGIONAL STAFF REPORT IV. INJECTION WELL PERMIT APPLICATIONS (Complete these two sections for all systems that use injection wells, including closed-loop groundwater remediation effluent injection wells, in situ remediation injection wells, and heat pump injection wells.) Description OfWell(S) And Facilities-New, Renewal, And Modification 1. Type of injection system: D Heating/cooling water return flow (5A7) ~ Closed-loop heat pump system (5QM/5QW) D In situ remediation (51) D Closed-loop groundwater remediation effluent injection (5L/"Non-Discharge") D Other (Specify: ) 2. Does system use same well for water source and injection? D Yes ~ No 3. Are there any potential pollution sources that may affect injection? D Yes ~ No What is/are the pollution sotirce(s)? 4. What is the minimum distance of proposed injection wells from the property boundary? 150 feet 5. Quality of drainage at site: ~ Good D Adequate D Poor 6. Flooding potential of site: ~ Low D Moderate D High 7. For groundwater remediation systems, is the proposed and/or existing groundwater monitoring program (number of wells, frequency of monitoring, monitoring parameters, etc.) adequate? D Yes D No. Attach map of existing monitoring well network if applicable. If No, explain and recommend any changes to the groundwater monitoring program: __ 8. Does the map presented represent the actual site (property lines, wells, surface drainage)?~ Yes or D No. If no or no map, please attach a sketch of the site. Show property boundaries, buildings, wells, potential pollution sources, roads, approximate scale, and north arrow. Injection Well Permit Renewal And Modification Onlv: 1. For heat pump systems, are there any abnormalities in ,heat pump or injection well operation (e.g. turbid water, failure to assimilate injected fluid, poor heating/cooling)? D Yes ~ No. If y es . exp lain: 2. For closed-loop heat pump systems, has system lost pressure or required make-up fluid since permit issuance or last inspection? D Yes ~ No. If v es, ex plain: 3. For renewal or modification of groundwater remediation permits (of any typ e), will continued/additional/modified injections have an adverse imp act on migration of the plume or management of the contamination incident? D Yes D No. If y es , exp lain: 1. Drilling contractor: Name: James Darby FORM: Staff.Report-Ashley Pessangno-2 4 AQUIFER PROTECTION REGIONAL STAFF REPORT 2. Address: 2512 Zink.er Road , Rock Hill , SC 27932 , 803-329-2424 Certification number: 2606 3. Complete and attach Well Construction Data Sheet. V . EVALUATION AND RECOMM:ENDATIONS 1. Provide any additional narrative regarding your review of the application.: 2. Attach Well Construction Data Sheet -if needed information is available 3. Do you foresee any problems with issuance/renewal of this permit? D Yes C8J No. If yes, please explain briefly. __ . 4 . List any items that you would like APS Central Office to obtain through an additional information request. Make sure that you provide a reason for each item: Item Reason 5. List specific Permit conditions that you recommend to be removed from the permit when issued. Make sure that you provide a reason for each condition: Condition Reason 6. List specific special conditions or compliance schedules that you recommend to be included in the permit when issued. Make sure that you provide a reason for each special condition: Condition Reason FORM: Staff.Report-Ashley Pessangno-2 5 AQUIFER PROTECTION REGIONAL STAFF REPORT 7. Recommendation: D Hold, pending receipt and review of additional information by regional office; D Hold, pending review of draft permit by regional office; D Issue upon receipt of needed additional information; ~ Issue; D Deny. If deny, please state reasons: __ 8 . Signature of report preparer(s): d.· n. oY\ l {.._ { ./--~ Signature of APS regional supervisor: ~ Date: i/z.1/2,,-, /k: ADDITIONAL REGIONAL STAFF REVIEW ITEMS A pre-permitting inspection was conducted on February 22, 2012. Three borings were proposed to construct with depth of 335 feet. Borings will be vertically drilled. A review of the construction data indicates that the proposal to construct the well meets the injection well construction criteria in accordance with N.C. State Regulations (Title 15A NCAC 2C), Well Construction Standards. The following items were checked: Grout type: bentonite; grout depth: from O feet to 335 feet Chemical additives to be used in closed-loop system: Propylene glycol We recommend that the Central Office proceed to issue the applicant a permit for geothermal well construction so that the contractor could start construction. FORM: Staff.Report-Ashley Pessangno-2 6 Permit: WI0500481 SOC: County: Chatham Region: Raleigh Effective: Effective: Contact Person: James Darby Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On-Site Representative( s ): Related Permits: Inspection Date: 02/22/2012 Primary Inspector: Lin McCartney Secondary lnspector(s): Reason for Inspection: Routine Compliance Inspection Report Expiration: Expiration: Title: Well Driller Certification: Owner: Ashley Pessagno Facility: Ashley Pessangno SFR 235 Buck Branch Rd Pittsboro NC 27312 Phone: 803-329-2424 Phone: Entry Time: 10:30 AM Exit Time: 11 :30 AM Phone: 919-791-4200 Ext.4243 Inspection Type: Compliance Evaluation Permit Inspection Type: Injection Mixed Fluid GSHP Well System (5QM) Facility Status: ■ Compliant D Not Compliant Question Areas: ■Other (See attachment summary) Page: 1 Permit: WI0500481 Inspection Date: 02/22/2012 Inspection Summary: Owner• Facility: Ashley Pessagno Inspection Type: Compliance Evaluation A Pre-permitting inspection was conducted on February 22, 2012. Reason for Visit: Routine Three boring were proposed to construct with depth of 335 feet. Borings will be vertically drilled. A review of the construction data indicates that the proposal to construct the well meets the injection well construction criteria in accordance with N.C. State Regulations (Title 15A NCAC 2C), Well Construction Standards. The following items were checked: Grout type: bentonite; grout depth from O feet to 335 feet Chemical Additives to be used in closed-loop system: Proylene glycol We recommend that the Central Office proceed to issue the applicant a permit for geothermal well construction so that the contractor could start construction. Other Comment: Yes No NA NE Page: 2