Loading...
HomeMy WebLinkAboutNCG551126_permit issuance_20010720Michael F. Easley Governor William G. Floss Jr., Secretary Department of Environment and Natural Resources Kerr T. Stevens, Director Division of Water Quality Mr. Steve Feierstein 204 Crawley Place Raleigh, NC 27712 Dear Mr: Feierstein: July 20, 2001 Subject: General Permit No. NCG550000 Cert. of Coverage NCG551126 Steve Feierstein Residence Person County On June 22, 2001, the Division of Water Quality issued a certificate of coverage under general permit No. NCG550000 to Steve Feierstein. A review of the certificate of coverage has indicated that an error was inadvertently made. Accordingly, we are forwarding herewith modifications to the subject cover letter and certificate of coverage to correct the error. This modification is issued to change Hyco River Class C to Hyco Lake Class B waters. Please find enclosed an amended cover letter and certificate of coverage page which should be inserted in your issued document. The old cover letter and certificate of coverage page should be discarded. All other terms and conditions contained in the cover letter and certificate of coverage remain unchanged and in full effect. This modification is issued pursuant to the requirements of North Carolina General Statutes 143-215.1 and the Memorandum of Agreement between North Carolina and the U.S. Environmental Protection Agency. If you have any questions concerning this permit, please contact Mack Wiggins at telephone number 919/733- 5083, extension 542. cc: Central Files Raleigh Regional Office, Water Quality Stormwater and General Permits Unit Point Source Compliance Enforcement Unit Person County Health Department Sincerely, err T. Stevens NCDENP Customer Service 1 800 623-7748 Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 (919) 733-7015 0��WAr�� Michael F. Easley Governor r William G. Ross Jr., Secretary Department of Environment and Natural Resources Kerr T. Stevens, Director Division of Water Quality July 20, 2001 Mr. Steve Feierstein 204 Crawley Place Raleigh, NC 27615 Subject: General Permit NCG550000 Cert. of Coverage NCG551126 Authorization to Construct Steve Feierstein Residence Person County Dear Mr. Feierstein: In accordance with your application for an NPDES discharge permit received March 8, 2001 by the Division, we have issued the Certificate of Coverage under the state-NPDES general permit for Steve Feierstein. Authorization is - hereby granted by this letter for the construction of a 480 GPD wastewater treatment system consisting of a 1250 gallon septic tank, 2,400 gal (min) pump chamber, distribution box with adjustable caps, two 210 square foot (6'X 35') primary sandfilters in parallel, with a loading rate of not more than 1.15 GPD/square foot for each filter, 210 square foot (6'X 35') secondary sandfilter with a loading rate of not more than 2.30 GPD/square foot, chlorinator, chlorine contact tank and rip rap aeration with a discharge of treated wastewater into Hyco Lake classified B waters in the Roanoke River Basin. All elbow piping must be of the long sweeping type. All cleanouts are to be housed in meter boxes below the surface. This system must be at least 10 feet from the dwelling and property lines and at least 100 feet from water supply wells on and off the site. The system must also be constructed and located above a 100 year flood. The trench must be lined with a minimum 30 mil polyethylene. If any parts, measurement frequencies or sampling requirements contained in this general permit are unacceptable to you, you have the right to submit an individual permit application and letter requesting coverage under an individual permit. Unless such demand is made, this decision shall be final and binding. Please take notice this permit is not transferable. Part II, E.4. addresses the requirements to be followed in case of change of ownership or control of this discharge. The Authorization to Construct is issued in accordance with Part III, Paragraph 2 of NPDES Permit No. NCG550000, and shall be subject to revocation unless the wastewater treatment facilities are constructed in accordance with the conditions and limitations specified in Permit No. NCG550000. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement wastewater treatment or disposal facilities. The Raleigh Regional Office, telephone number 919/571-4700, shall be notified at least forty-eight (48) hours in advance of operation of the installed facilities so that an in -place inspection can be made. Such notification to the regional supervisor shall be made during the normal office hours from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays. Upon completion of construction and prior to operation of this permitted facility, a certification must be received certifying that the permitted facility has been installed in accordance with the NPDES Permit, the Certificate of Coverage, this Authorization to Construct and the approved plans and specifications. Mail the Certification to the Stormwater and General Permits Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. NCDENR Customer Service 1 800 623-7748 Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 (919) 733-7015 Michael F. Easley Governor rWilliam G. Ross Jr., Secretary Department of Environment and Natural Resources Kerr T. Stevens, Director Division of Water Quality A copy of the approved plans and specifications shall be maintained on file by the Permittee for the life of the facility. The sand media of the sandfilters-must comply with the Division's sand specifications. The engineer's certification will be evidence that this certification has been met. A leakage test shall be performed on the septic tank and dosing tank to insure that any exfiltration occurs at a rate which does not exceed twenty (20) gallons per twenty-four (24) hour per 1,000 gallons of tank capacity. The engineer's certification will serve as proof of compliance with this condition. Failure to abide by the requirements contained in this Authorization to Construct may subject the Permittee to an enforcement action by the Division of Water Quality in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be required by the Division of Water Quality or permits required by the Division of Land Resources, the Coastal Area Management Act or any Federal or Local other governmental permit that may be required. If you have any questions or need additional information, please contact Mack Wiggins, telephone number 919/733-5083. cc: Central Files Raleigh Regional Office, Water Quality Roosevelt Childress, EPA Point Source Compliance Enforcement Unit Person County Health Department Sincerely, iJasauci— err T. Stevens. FIMENR Customer Service 1 800 623-7748 Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 (919) 733-7015 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY CERTIFICATE OF COVERAGE GENERAL PERMIT NO. NCG551126 TO DISCHARGE DOMESTIC WASTEWATERS FROM SINGLE FAMILY RESIDENCES AND OTHER DISCHARGES WITH SIMILAR CHARACTERISTICS UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with , the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Steve Feierstein is hereby authorized to operate and construct a wastewater treatment facility that consists of a septic tank, pump chamber, distribution box, dual primary sandfilters, secondary sandfilter, chlorinator, chlorine contact tank, rip rap aeration and associated appurtenances with the discharge of treated wastewater from a facility located at the Steve Feierstein Residence Oak Pointe Subdivision, Lot # 49 northwest of Roxboro Person County to receiving waters designated as Hyco Lake in the Roanoke River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III and IV hereof. This certificate of coverage shall become effective July 20, 2001 This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day July 20, 2001 Kerr T. Stevens, Director Division of Water Quality By Authority of the Environmental Management Commission -, l Ottm ngham •- i. ()SO 'A E' Eti \ • a • tt� ems, skruu 8° W w \ r Copyright (C) 1997, Maptech, Inc. 4 5