Loading...
HomeMy WebLinkAboutWI0800547_Permit (Issuance)_20210331ATC ENVIRONMENTAL • GEOTECHNICAL BUILDING SCIENCES • MATERIALS TESTING 2725 East Millbrook Road Suite 121 Raleigh, NC 27604 Tel: 919-871-0999 Fax: 919-871-0335 www.atcgroupservices.com N.C. Engineering License No. C-1598 March 15, 2021 Ms. Shristi Shrestha North Carolina Department of Environmental Quality Division of Water Quality - Aquifer Protection Section, UIC Program 1636 Mail Service Center Raleigh, North Carolina 27699-1636 Reference: Notice of Intent to Construct or Operate Injection Wells Woodcock Oil Company 700 East Church Street Atkinson, Pender County, North Carolina NCDEQ Incident No. 16996 Dear Ms. Shrestha: Ftzekvzo MQR �:2021 Office ATC Associates of North Carolina, P.C. (ATC) has prepared the enclosed Notice of Intent to Construct or Operate Injection Wells on behalf of the North Carolina Department of Environmental Quality State -Lead Program. The permit application covers the performance of passive remediation in three monitoring wells associated with the above referenced site If you have questions or require additional information, please contact our office at (919) 871-0999. Sincerely, ATC Associates of North Carolina, P.C. Ashley M. Winkelman, P.G. Senior Project Manager cc: Hassan Osman, Hydrogeologist for NCDEQ Attachments Notice of Intent to Construct or Operate Injection Wells Woodcock Oil Company, Atkinson, North Carolina NOTICE OF INTENT FORM 14TC EIIYIE0111EEIIL• 0E01EC66ICEL R1110116 SCIENCES • 6ETEIIELE TESTING NC Department of Environmental Quality — Division of Water Resources (DWR) NOTIFICATION OF INTENT (NOI) TO CONSTRUCT OR OPERATE INJECTION WELLS The following are `permitted by rule" and do not require an individual permit when constructed in accordance with the rules of 15A NCAC 02C.0200 (NOTE: This form must be received at least 14 DAYS prior to injection) AQUIFER TEST WELLS (15A NCAC 02C .0220) These wells are used to inject uncontaminated fluid into an aquifer to determine aquifer hydraulic characteristics. IN SITU REMEDIATION (15A NCAC 02C .0225) or TRACER WELLS (15A NCAC 02C .0229): 1) Passive Injection Systems - In -well delivery systems to diffuse injectants into the subsurface. Examples include ORC socks, iSOC systems, and other gas infusion methods (Note: Injection Event Records (IER) do not need to be submitted for replacement of each sock used in ORC systems). 2) Small -Scale Injection Operations — Injection wells located within a land surface area not to exceed 10,000 square feet for the purpose of soil or groundwater remediation or tracer tests. An individual permit shall be required for test or treatment areas exceeding 10,000 square feet. 3) Pilot Tests - Preliminary studies conducted for the purpose of evaluating the technical feasibility of a remediation strategy in order to develop a full scale remediation plan for future implementation, and where the surface area of the injection zone wells is located within an area that does not exceed five percent of the land surface above the known extent of groundwater contamination. An individual permit shall be required to conduct more than one pilot test on any separate groundwater contaminant plume. 4) Air Injection Wells - Used to inject ambient air to enhance in -situ treatment of soil or groundwater. 5) In -Situ Thermal Wells (IST) — Used to `heat' contaminated groundwater to enhance remediation Print Clearly or Type Information. Illegible Submittals Will Be Returned as Incomplete. DATE: March 15 , 2021 PERMIT NO. WI0800547 (to be filled in by DWR) NOTE- If this NOI is being submitted as notification of a modification of a previously issued NOI for this site (e.g., different injection wells, plume, additives, etc.) and still meets the deemed permitted by rule criteria, provide the previously assigned permit tracking number and any needed relevant information to assess and approve injection: A. B. Permit No. WI Issued Date: WELL TYPE TO BE CONSTRUCTED OR OPERATED (1) Air Injection Well Complete sections B through F, J, M (2) Aquifer Test Well Complete sections B through F, J, M (3) X Passive Injection System ..Complete sections B through F, H-M (4) Small -Scale Injection Operation.. .Complete sections B through M (5) Pilot Test Complete sections B through M (6) In -Situ Thermal (IST) Well Complete all sections except K STATUS OF WELL OWNER: State Government Deemed Permitted GW Remediation NOI Rev. 2-14-2020 Page 1 C. WELL OWNER(S) — State name of Business/Agency, and Name and Title of person delegated authority to sign on behalf of the business or agency: Name: Hassan Osman — Hydrogeologist, North Carolina Department of Environmental Quality Mailing Address: 1646 Mail Service Center City: Raleigh State: NC Zip Code: 27699-1646 County: Wake Day Tele No.: 919-707-8167 Cell No.: Not Available EMAIL Address: hassan.osman( ncdenr.gov Fax No.: Not Available D. PROPERTY OWNER(S) (if different than well owner/applicant) Name and Title: Maulin Patel Company Name Not Applicable Mailing Address: 126 W. Church St City: Atkinson State: NC Zip Code: 28421 County: Pender Day Tele No.: 919-922-0563 Cell No.: Not Available EMAIL Address: Not Available Fax No.: Not Available E. PROJECT CONTACT (Typically Environmental Consulting/Engineering Firm) Name: Ashley M. Winkelman — ATC Associates of North Carolina, P.C. Mailing Address: 2725 E. Millbrook Road. Suite 121 City: Raleigh State: NC_ Zip Code:27604 _ County: Wake Day Tele No.: 919-871-0999 Ce11 No.: 919-830-3576 EMAIL Address: ashley.winkelman@atcgs.com F. PHYSICAL LOCATION OF WELL SITE (1) Facility Name & Address: _ Woodcock Oil Company 700 East Church Street Fax No.: 737-207-8261 City: Atkinson County: Pender Zip Code: 28421. (2) Geographic Coordinates: Latitude**: 0 " or 34 °.53189. Longitude**: " or 78 °. 16374 Reference Datum: WGS84 Accuracy: 10-meter Method of Collection: DO() — Acme Mapper 2.2 **FOR AIR INJECTION AND AQUIFER TEST WELLS ONLY: A FACILITY SITE MAP WITH PROPERTY BOUNDARIES MAY BE SUBMITTED IN LIEU OF GEOGRAPHIC COORDINATES. G. TREATMENT AREA Land surface area of contaminant plume: square feet Land surface area of inj. well network: square feet (< 10,000 ft2 for small-scale injections) Percent of contaminant plume area to be treated: (must be < 5% of plume for pilot test injections) Deemed Permitted GW Remediation NOI Rev. 2-14-2020 Page 2 H. INJECTION ZONE MAPS — Attach the following to the notification. (1) Contaminant plume map(s) with isoconcentration lines that show the horizontal extent of the contaminant plume in soil and groundwater, existing and proposed monitoring wells, and existing and proposed injection wells; and Included in the Figures section. (2) Cross-section(s) to the known or projected depth of contamination that show the horizontal and vertical extent of the contaminant plume in soil and groundwater, changes in lithology, existing and proposed monitoring wells, and existing and proposed injection wells. Included in the Figures section. (3) Potentiometric surface map(s) indicating the rate and direction of groundwater movement, plus existing and proposed wells. Included in the Figures section. DESCRIPTION OF PROPOSED INJECTION ACTIVITIES AT THE SITE — Provide a brief narrative regarding the cause of the contamination, and purpose, scope, goals of the proposed injection activity: ATC will install three Provect ORS sleeves each in monitoring wells AMW-4, AMW-8. and AMW-9 in order to aide in natural attenuation and reduce compounds concentrations to below the North Carolina Groundwater Quality Standards (2L Standards). Based on the most recent sampling event performed in May. 2020, the following compounds exceeded the 2L Standards: benzene and naphthalene. The sleeves come in 3-foot sections. ATC will install three 3-foot sections at the base of the wells, across the well screen. The socks will release oxidizing solids into the groundwater for approximately 6 months, at which point the chemicals in the socks will have depleted. J. WELL CONSTRUCTION DATA (1) No. of injection wells: Proposed 3 Existing (provide NC Well Construction Record (GW-1) for each well) Included in Appendix B (2) Appx. injection depths (BLS): 8.5-19.5 (3) For Proposed wells or Existing wells not having GW-ls, provide well construction details for each injection well in a diagram or table format. A single diagram or line in a table can be used for multiple wells with the same construction details. Well construction details shall include the following (indicate if construction is proposed or as -built): (a) Well type as permanent, Geoprobe/DPT, or subsurface distribution infiltration gallery (b) Depth below land surface of casing, each grout type and depth, screen, and sand pack (c) Well contractor name and certification number K. INJECTION SUMMARY NOTE: Only injectants approved by the epidemiology section of the NC Division of Public Health, Department of Health and Human Services can be infected. Approved iniectants can be found online at http://deq.nc.eov/about/divisions/water-resources/water-resources-permits/wastewater-branch/ground-water- protection/ground-water-approved-iniectants. All other substances must be reviewed by the DHHSprior to use. Deemed Permitted GW Remediation NOI Rev. 2-14-2020 Page 3 Contact the UIC Program for more info if you wish to get approval for a different additive. However, please note it may take 3 months or longer. Injectant: Provect ORS Sleeves Total Amt. to be injected (gal)/event: 3,114 in3 (volume of sleeves) Amt. Water to be injected (gal/event): N/A Total Amt. to be injected (gal/event): 3.114 in3 (volume of sleeves) No. of separate injection events:1 Est. Total Amt. to be injected (gal): 3,114 in3 (volume of sleeves) Source of Water (if applicable): N/A L. MONITORING PLAN — Describe below or in separate attachment a monitoring plan to be used to determine if violations of groundwater quality standards specified in Subchapter 02L result from the injection activity. Approximately 6 months after the installation of the Provect ORS sleeves. ATC will collect a sample from the wells for analysis of volatile organic compounds by EPA Method 6200B. The samples will be shipped to Pace Analytical in Mt. Juliet, Tennessee. ATC will also measure dissolved oxygen. conductivity temperature, pH. and oxygen reduction potential during the sampling event. M. SIGNATURE OF APPLICANT AND PROPERTY OWNER Well Owner/Applicant: "I hereby cert, under penalty of law, that I am familiar with the information submitted in this document and all attachments thereto and that, based on my inquiry of those individuals immediately responsible for obtaining said information, I believe that the information is true, accurate and complete. I am aware that there are significant penalties, including the possibility of fines and imprisonment, for submitting false information. I agree to construct, operate, maintain, repair, and if applicable, abandon the injection well and all related appurtenances in accordance with the 15A NCAC 02C 0200 Rules." Ashley Winkelman on behalf of Hassan Osman, NCDEO Signature of Applicant Print or Type Full Name and Title Property Owner (if the property is not owned by the Well Owner/Applicant): "As owner of the property on which the injection well(s) are to be constructed and operated, I hereby consent to allow the applicant to construct each injection well as outlined in this application and agree that it shall be the responsibility of the applicant to ensure that the injection well(s) conform to the Well Construction Standards (15A NCAC 02C .0200)." "Owner" means any person who holds the fee or other property rights in the well being constructed. A well is real property and its construction on land shall be deemed to vest ownership in the land owner, in the absence of contrary agreement in writing. See Appendix C Maulin Patel Signature* of Property Owner (if different from applicant) Print or Type Full Name and Title *An access agreement between the applicant and property owner may be submitted in lieu of a signature on this form. Deemed Permitted GW Remediation NOI Rev. 2-14-2020 Page 4 Please send 1 (one) hard color copy of this NOI along with a copy on an attached CD or Flash Drive at least two (2) weeks prior to injection to: DWR — UIC Program 1636 Mail Service Center Raleigh, NC 27699-1636 Telephone: (919) 707-9000 Deemed Permitted GW Remediation NOI Rev. 2-14-2020 Page 5 Ashley Winkelman From: Osman, Hassan <hassan.osman@ncdenr.gov> Sent: Monday, March 15, 2021 11:09 AM To: Ashley Winkelman Subject: RE: [External] #16996 Woodcock Oil NOI Hassan Osman from UST Section, Trust Fund Brach, I am giving a permission ATC to submit NOI on behalf of UST Section, Trust Fund Brach. If you have any questions you can contact at (919) 707-8167. Thanks Hassan From: Ashley Winkelman <ashley.winkelman@atcgs.com> Sent: Monday, March 15, 2021 10:59 AM To: Osman, Hassan <hassan.osman@ncdenr.gov> Subject: [External] #16996 Woodcock Oil NOI CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Hey Hassan, I'm getting ready to submit the Notice of Intent for the ORS Sleeve installation at Woodcock Oil. Can you respond to this email giving me permission to sign the NOI on your behalf? Ashley M. Winkelman PGI SENIOR PROJECT MANAGER I ATC Group Services LLC Direct +1 919 573 1206 I Cell +1 919 830 3576 "- 1 2725 E. Millbrook Road, Suite 121 I Raleigh, NC 27604 Fax +1 919 871 0335 I ashley.winkelman_Y;atcgs.com I www.atcgroupservices.com This email and its attachments may contain confidential and/or privileged information for the sole use of the intended recipient(s). If you are not the intended recipient, any use, distribution or copying of the information contained in this email and its attachments is strictly prohibited. If you have received this email in error, please notify the sender by replying to this message and immediately delete and destroy any copies of this email and any attachments. The views or opinions expressed are the author's own and may not reflect the views or opinions of ATC. 1 Notice of Intent to Construct or Operate Injection Wells Woodcock Oil Company, Atkinson. North Carolina FIGURES ATC EMEIRNNNENTAL • REATECNIICAL INILIING SCIENCES • MATERIALS TESTING H:V20201OTHER OFFICESWORTH CAROLINAWCDEQ-STATE LEADIWOODCOCK OILISLP1699602•BENZ.DWG, FIG5 v ♦ ♦ ♦ ♦ LEGEND: LEGEND: AMW-11 MONITORING WELL 450.50 - Well Idanlfication Benzene Concentration(Ng/L) T-1 TYPE III MONITORING WELL Well Identification An_CCDW-1 WATER SUPPLY WELL Well Identification }CCDW-2 ABANDONED WATER SUPPLY WELL Well Identification ---- SITE PROPERTY LINE PARCEL LINE —P—P— FORMER PRODUCT PIPING w---w— WATER LINE g FORMER DIESEL DISPENSER O FORMER KEROSENE DISPENSER © FORMER GASOLINE DISPENSER BENZENE ISOCONCENTRATION CONTOUR (DASHED WHERE INFERRED) (pg/L) NOTE: ALL LOCATIONS ARE APPROXIMATE �'� • T-1+ \\ \\ N 0 NS1. \\ `\ m�� MW-V j \\TN1nA 0.21J , \ 2 a ' o I`;_ �lPM 50R+T 2 \1S *AMW-10 WSW-3 WSW-1 \vv7 ♦ ♦ ♦ ♦ ♦ • +AMW-1 • • ♦ • a ....'\ 0 _' \ \ � MW2 .1ik, \ AMW-9 _� - \\ \\\\ \ - \ \ \ \0 \ FORMER AST\\ LOCATION \\ ♦♦ AMW-5 \ \ \ \ \ \ \ s ♦ • RESIDENTIAL FORMER UST BASIN z Z i A \ WSW-24- (ABANDONED) +AMW-6 \ \ \ \ \ —nNSW-3A RESIDENTIAL • ♦ ♦ AMW-11 M 0-4 AMW-16 • i'�" rr4t a le_. r . AMW-12 -<050 ♦ ♦ ♦ :off s -4 t 'Ira r r� s • • 4.0 -•, 1. 14 tqa L' AMW-13 �. 1 A ti AMW-1 5 ♦ 144- r 5 - • 0 ✓ f 162 4 44rN i *T 1 +AMW-17 AMW-14 40 N 1 • 0 10 70 30 40 7 —1 SCALE: 1" = 40' 6 0 6 LL re co re 9 0 U 5. n 0 U woject Numoer: SLP1699602 of an authoritative location, nor are they presented cL 2 0 1- 0 0 0 0 w Z 0 0 (1) w w Z w WOODCOCK OIL CO. = INCIDENT #16996 700 EAST CHURCH STREET ATKINSON, PENDER COUNTY, NORTH CAROLINA Date: 6120 Scale: AS SHOWN Figure: LEGEND: AMW-11 MONITORING WELL . 1.0 ! �- Well Identification TT Naphthalene Concentration (pg/L) T-1 TYPE III MONITORING WELL Well Identification CCDW-1 WATER SUPPLY WELL �--- Well Identification CCDW-2 ABANDONED WATER SUPPLY WELL Well Identification -- SITE PROPERTY LINE - PARCEL LINE —P—P— FORMER PRODUCT PIPING — —W— WATER LINE El FORMER DIESEL DISPENSER E FORMER KEROSENE DISPENSER © FORMER GASOLINE DISPENSER NAPHTHALENE ISOCONCENTRATION CONTOUR (DASHED WHERE INFERRED) (pg/L) NOTE: ALL LOCATIONS ARE APPROXIMATE ���'c° tom/ /,/ r -- "gip' AMW-3R+T2 \AMW-7 *AMW-1 ANA f MW- AMW-3 A AMW-10 • /I --/ ter-- i FORMER UST BASIN RESIDENTIAL 1 • \ \ A 1\ ,01 FORMER LOCATION AMW-4 1Cl 1 '1 L r^111* * el ' RESIDENTIAL AMW-16 WSW-24f (ABANDONED) +AMW-6 • AMW-15 T �' taw, Or S. 4•• N ti• 4 ' • • 0 0 10 30 40 tttttttttttf lllllllll� SCALE: 1" = 40' E U U o. 3 0 CD 0 0 tL 0 0 Z 0 Z O Q co IZ W 10 0 J w 10 WOODCOCK OIL CO. - INCIDENT #16996 700 EAST CHURCH STREET ATKINSON, PENDER COUNTY, NORTH CAROLINA l— W 5- w CC CO CO ci 3 0 cU cC co I- Z Z 1 o U Date: 6/20 Scale: AS SHOWN Figure: GRAVEL AREA P-1 (6") P-1 (10''). S-b0r 1 1 PAVED 1 $� AREA fe L Former Gasoline Dis nsers STORE Former UST Basin I DL 1 i► 111 S-8 Of AP/ 11 S-71 / /DL2 li LB1 DW-1 LEGEND • Soil Sample Location * Domesfic Well Location Former Loading Rack Former Kerosene Dispenser 11 DL-6 11 1 L-8 11 DL-7 VP- [ 7 • 1 DL-8 0 Dispenser Line Trench Excavation TIL-2 Former Diesel L-3 and Kerosene I-� Dispensers L-4 -_- nag AST-3 FORMER . l OFFICE 5: 1 1 DL-9 DL-10W eAST-6 • DL-lo • Approx. Limits Of Excavation AST-4 • 1 AST-5 11111 1 c W 70\"*. pplied Resource Management PC P.O. Box 882, Haptead, NC 28443 {9T0)270.29T9FAX 270-2988 TITLE: SITE MAP WITH ABATEMENT SOIL SAMPLE LOCATIONS JOB: ; SCALE: DATE: : DRAWN BY: 9914 1" = 40' 1 /9/03 JLC/EFC FIGURE: 2 • VR% MOW.1 ■RI ■% VRRow VVMR■ n.. ■ . ATKINSON, NORTH CAROLINA Concentrations in Parts Per Million (mg/Kg) SAMPLE LOCATION EPA METHOD FIELD IDENTIFICATION MAP IDENTIFICATION SAMPLE DATE SAMPLE DEPTH 3550 5030 Pit 1 P-1 816/02 6' <10 <5 Pit 1 P-1 8/6/02 10' <10 <5 SW-1 S-1 8/6/02 12' <10 <5 SSW-1 S-2 • 8/8/02 8' <10 296 SSW-2 S-3 8/12./02 8' <10 <5 EESW-1 S-4 8/12/02 6' <10 <5 CWSW 1 S-5 8/8/02 8' <10 39.7 NWESW-1 S-6 8/9/02 8' <10 <5 NECSW-1 S-7 8/9/02 8' <10 <5 NEESW-1 S-8 8/9/02 8' <10 <5 DL-2 DL-2 8/7/02 4' <10 <5 DL-3 DL-3 8/7/02 4' <10 <5 ESWDL-4 DL-4 8/7/02 8-9' <10 <5 DL-5 DL-5 8/12/02 4' <10 <5 DL-6 DL-6 8/12/02 4' <10 <5 DL-7 DL-7 8/13/02 4' <10 <5 DL-8 DL-8 8113/02 4' <10 <5 DL-9 DL-9 8/13/02 4' <10 <5 DL-10 DL-10 8/13/02 4' <10 <5 OL-1.OW DL-10W 8/13/02 6' <10 <5 LRNSW-3 L-1 8/12/02 6-8' <10 y <5 LRNSW-2 L-2 8/12/02 6-8' <10 <5 LRNSW-1 L-3 8/12/02 5' 923 <5 L,RESW-1 L-4 8112/02 5' <10 <5 LRESW-2 L-5 8/12/02 6' <10 <5 LRSSW-1 L-6 8/12/02 8' <10 <5 LRWSW-1 L-7 8/12/02 8' <10 <5 LRSW 2 L-8 8/12/02 8' 11.6 <5 AST-1 AST-1 8/12/02 3' <10 <5 • AST-2 AST-2 8/12/02 3' <10 <5 AST-3 AST-3 8/12/02 3' <10 l <5 AST-4 AST-4 8/12/02 2" <10 <5 AST-5 AST-5 8/12/02 2' <10 <5 AST-6 AST-6 8/12/02 2' <10 <5 Shaded areas represent non compliant hydrocarbon concentrations. Noncompliant defined as 40 mg/kg for EPA Method 3550, and 10 mg/kg for EPA Method 5030. AMW-8 (99.57) Gasol Dlsp PAVED B-10 AREA LEGEND GRAVEL AREA T-1 Former tloo.00) UST Basin 9 1 8) Former • Kerosene Dispenser STORE B AMW-10 (99.18) -149 (99.05) AMW-9 (99.40) AMW-2(9 (99.10) LB1 DW-1 f FORMER 1:411k OFFtCE Former Ir UST Basin 1 AMW-4 (98.65) • Exploratory Boring Location 9 Type II Monitoring Well Location Type Iil Monitoring Well Location * Approximate Domestic Well Location (94.15) Top of Casing Elevation (in feet) • S-1 B-60 53 AMW-7 (98.33) B' GRASSED AREA CNP`R CE >� E Nay' Diesel and Kerosene Dispensers • Diesel A51 Di®ol lS1 AMW-6 (96.42) CCDW-1 • B-3 S-3 AMW-59 S-2 (96.57) 5A O B-5 CCDW-2 9 AMW-11 (98.15) AMW-12S (95.14) AP pplied Resource Management PC .O. Box 882 Hampstead NC 28443 MO 210-29Ca F.AX 210-29as TITLE: SITE MAP WITH AQUIFER TRANSECT LOCATIONS JOB: 9914 SCALE: 1" = 40' DATE: DRAWN BY: 5/16/00 DHC FIGURF: 0 p? A . I a )2, m 0 0 < E 2 co ,V-V 103SNVd1 d3d1110V 120.00 - — 100.00 80.00 — 60.00 40.00 A AMW-8 B-2 AMW-3 T-2 AMW-9 AMW-2 B-4 E3-.3 (99.57') (99.96) (100.07), (99.40') (99.10') LEGEND SP - Poorly graded sands or gravelly 20,00 — sands, little or no fines. CH - inorganic clays of high plasticity, fat clays. SC - Clayey sands, sand -clay mixtures. 00.00 A' AMW-12 (95.14') Groundwater table elevation as of 3/21 /00. Scale: 1 '=40' horiz. 1"=20' vert. 40 80 120 160 200 240 280 0 0 D ^J V' 7-1 0 � D o z co i ,9 a 133SN`d21.. dEI:Inev G) c m 120,00 100.00 80,00 60.00 40.00 20.00 00.00 -- B AMW-10 (99.18') T-2 AMW-7 (700.07') (99.05') LEGEND Br AMW-7 (98.33') SP SP - Poorly graded sands or gravelly sands, little or no fines. CH - Inorganic clays of high plasticity, fat clays. . SC - Clayey sands, sand -clay mixtures. r _ Groundwater table elevation asof3/21/00. Scale: 1'=40' horiz. 1 "=20' vert. 40 80 120 160 200 240 280 Gradient = 0.0221 ftift OiL ,teV 44Z, No NM \� \a \ \ A 88,42. , >sterZ /-7( - -d9,11 AMW-8 ,d • • • • LEGEND: AMW-11 \ MONITORING WELL 4E18.32 1 T- Well Identification Relative Groundwater Elevation(f) T-1 TYPE III MONITORING WELL Well Identification ,CCDW-1 WATER SUPPLY WELL Well Identification rhCCDW-2 ABANDONED WATER SUPPLY WELL T �-- Well Identification SITE PROPERTY LINE PARCEL LINE FORMER PRODUCT PIPING WATER LINE FORMER DIESEL DISPENSER FORMER KEROSENE DISPENSER FORMER GASOLINE DISPENSER GROUNDWATER ELEVATION CONTOUR (DASHED WHERE INFERRED) GROUNDWATER FLOW DIRECTION NOTE: ALL LOCATIONS ARE APPROXIMATE RESIDENTIAL AMW-2 \\ \ \A\ :•.,ERAST \\ LOCA - \ \ 4 \\ 87.97 WSW-2 (ABANDONED) T-14- +AMW-11 T WSW-3 ��Ah9W-7 CRMER l IN RESIDENTIAL 'AMW-16 r � 441164^0, _ AMW-17 NM 0 10 20 SCALE:1" = 40' Scale: AS SHOWN Figure: 4 Notice of Intent to Construct or Operate Injection Wells Woodcock Oil Company. Atkinson, North Carolina APPENDIX A MSDS FORM 34TC ENTINONNENTAL• BEOTECNNICAL BUILOINB SCIENCES • MATERIALS 'EMIRS rovectus ENVIRONMENTAL PRODUCTS" MATERIAL SAFETY DATA SHEET: PROVECT-ORS Page: 1 of 5 1. PRODUCT IDENTIFICATION: PROVECT-ORS PRODUCT USE: Soil and water treatment. MANUFACTURER: EMERGENCY PHONE: PROVECTUS ENVIRONMENTAL 2871 W. Forest Rd., Suite 2 Freeport, IL 61032 USA: (815) 650-2230 TRANSPORTATION OF DANGEROUS GOOD CLASSIFICATION: Oxidizing Solid, n.o.s. (Calcium Peroxide), Class 5.1, PG II, UN1479 WHMIS CLASSIFICATION: Oxidizer 2. COMPOSITION/INFORMATION ON INGREDIENTS Ingredients Calcium Peroxide Inorganic Nutrients 3. PHYSICAL DATA Chemical Formula CaO2 CAS No. Percentage 1305-79-9 75%-85% 15%-25% Appearance White & brown granules Physical state Solid Odor threshold None Bulk Density 500-650g/L Solubility in Water Insoluble pH —11 Decomposition Temperature Self -accelerating decomposition with oxygen release starting from 275 degrees Celsius 4. HAZARDS IDENTIFICATION Emergency overview Oxidizing agent, contact with other material may cause fire. Under fire conditions this material may decompose and release oxygen that intensifies fire. This product contains <1% non -respirable crystalline silica. The NTP and OSHA have not classified non -respirable crystalline silica as carcinogenic. Long term exposure to hazardous levels of respirable silica dusts can cause lung disease (silicosis). ORS does not contain respirable crystalline silica. Potential Health Effects: • General Irritating to mucous membrane and eyes. i.»• 'ovectus ENVIRONMENTAL PRODUCTS" MATERIAL SAFETY DATA SHEET: PROVECT-ORS Page: 2 of 5 • Inhalation Irritating to respiratory tract. Long term inhalation of elevated levels may cause lung disease (silicosis). • Eye contact May cause irritation to the eyes; Risks of serious or permanent eye lesions. • Skin contact May cause skin irritation. • Ingestion Irritation of the mouth and throat with nausea and vomiting. 5. FIRST AID MEASURES • Inhalation Remove affected person to fresh air. Seek medical attention if effects persist. • Eye contact Flush eyes with running water for at least 15 minutes with eyelids held open. Seek specialist advice. • Skin contact Wash affected skin with soap and mild detergent and large amounts of water. • Ingestion If the person is conscious and not convulsing, give 2-4 cupfuls of water to dilute the chemical and seek medical attention immediately. Do not induce vomiting. 6. FIRE FIGHTING MEASURE Flash Point • Not applicable Flammability • Not applicable Ignition Temperature • Not applicable Danger of Explosion • Non -explosive Extinguishing Media • Water Fire Hazards • Oxidizer. Storage vessels involved in a fire may vent gas or rupture due to internal pressure. Damp material may decompose exothermically and ignite combustibles. Oxygen release due to exothermic decomposition may support combustion. May ignite other combustible materials. Avoid contact with incompatible materials such as heavy metals, reducing agents, acids, bases, ` rovectus ENVIRONMENTAL PRODUCTS" MATERIAL SAFETY DATA SHEET: PROVECT-ORS Page: 3 of 5 combustible (wood, papers, cloths etc.) Thermal decomposition releases oxygen and heat. Pressure bursts may occur due to gas evolution. Pressurization if confined when heated or decomposing. Containers may burst violently. Fire Fighting Measures • Evacuate all non -essential personnel • Wear protective clothing and self-contained breathing apparatus. • Remain upwind of fire to avoid hazardous vapors and decomposition products. • Use water spray to cool fire- exposed containers. 7. ACCIDENTAL RELEASE MEASURES Spill Clean-up Procedure • Oxidizer. Eliminate all sources of ignition. Evacuate unprotected personnel from equipment recommendations found in Section 9. Never exceed any occupational exposure limit. • Shovel or sweep material into plastic bags or vented containers for disposal. Do not return spilled or contaminated material to inventory. Avoid making dust. • Flush remaining area with water to remove trace residue and dispose of properly. Avoid direct discharge to sewers and surface waters. Notify authorities if entry occurs. • Do not touch or walk through spilled material. Keep away from combustibles (wood, paper, oils, etc.). Do not return product to container because of risk of contamination. 8. HANDLING AND STORAGE Storage • Oxidizer. Store in a cool, well -ventilated area away from all source of ignition and out of direct sunlight. Store in a dry location away from heat. • Keep away from incompatible materials. Keep containers tightly closed. Do not store in unlabeled or mislabeled containers. • Protect from moisture. Do not store near combustible materials. Keep containers well sealed. Ensure pressure relief and adequate ventilation. • Store separately from organics and reducing materials. Avoid contamination that may lead to decomposition. Handling • Avoid contact with eyes, skin, and clothing. Use with adequate ventilation. • Do not swallow. Avoid breathing vapors, mists, or dust. Do not eat, drink, or smoke in work area. • Prevent contact with combustible or organic materials. • Label containers and keep them tightly closed when not in use. • Wash thoroughly after handling. i)rovectus ENVIRONMENTAL PRODUCTS' MATERIAL SAFETY DATA SHEET: PROVECT-ORS Page: 4 of 5 9. EXPOSURE CONTROLS/PERSONAL PROTECTION Engineering Controls • General room ventilation is required. Local exhaust ventilation, process enclosures or other engineers controls may be needed to maintain airborne levels below recommended exposure limits. Avoid creating dust or mist. Maintain adequate ventilation. Do not use in closed or confined spaces. Keep levels below exposure limits. To determine exposure limits, monitoring should be performed regularly. Respiratory Protection • For many condition, no respiratory protection may be needed; however, in dusty or unknown atmospheres or when exposures exceed limit values, wear a NIOSH approved respirator. Eye/Face Protection • Wear chemical safety goggles and a full face shield while handling this product. Skin Protection • Prevent contact with this product. Wear gloves and protective clothing depending on condition of use. Protective gloves: Chemical -resistant (Recommended materials: PVC, neoprene or rubber) Other Protective Equipment • Eye -wash station • Safety shower • Impervious clothing • Rubber boots General Hygiene Considerations • Wash with soap and water before meal times and at the end of each work shift. Good manufacturing practices require gross amounts of any chemical removed from skin as soon as practical, especially before eating or smoking. 10. STABILITY AND REACTIVITY Stability • Stable under normal conditions Condition to Avoid • Water • Acids • Bases • Salts of heavy metals • Reducing agents • Organic materials • Flammable substances Hazardous Decomposition Products • Oxygen which supports combustion rovectus ENVIRONMENTAL PRODUCTS" MATERIAL SAFETY DATA SHEET: PROVECT-ORS Page: 5 of 5 11. TOXICOLOGICAL INFORMATION • LD50 Oral: Min.2000 mg/kg, rat • LD50 Dermal: Min. 2000mg/kg, rat • LD50 Inhalation: Min. 4580 mg/kg, rat 12. ECOLOGICAL INFORMATION Ecotoxicological Information • Hazards for the environment is limited due to the product properties of no bioaccumulation, weak solubility and precipitation in aquatic environment. Chemical Fate Information • As indicated by chemical properties oxygen is released into the environment. 13. DISPOSAL CONSIDERATIONS Waste Treatment • Dispose of in an approved waste facility operated by an authorized contractor in compliance with local regulations. Package Treatment • The empty and clean containers are to be recycled or disposed of in conformity with local regulations. 14. TRANSPORT INFORMATION • Proper Shipping Name: EHC-O • Hazard Class: 5.1 • Labels: 5.1 (Oxidizer) • Packing Group: II 15. REGULATORY INFORMATION • SARA Section Yes • SARA (313) Chemicals No • EPA TSCA Inventory Appears • Canadian WHMIS Classification C, D2B • Canadian DSL Appears • EINECS Inventory Appears Notice of Intent to Construct or Operate Injection Wells Woodcock Oil Company, Atkinson, North Carolina APPENDIX B MONITORING WELL CONSTRUCTION DETAILS i4TC E1111RRMREMIML • iER1ECNNICMI 1111101116 SLIMES • MEWLS TESTING North Carolina - Department of Environement and Natural resources - Division of Water Quality - Groundwater Section 1936 Mall Service Center- Raleigh, N.C. 27699-1636- Phone (919) 733.3221 WELL CONSTRUCTION RECORD AMW-4 WELL CONTRACTOR: ARM's Waterworks - Don Cummings WELL CONTRACTOR CERTIFICATION #: 2412 STATE WELL CONSTRUCTION PERMIT #: 1. WELL USE (Check Applicable Box): Recovery Heat Pump Water injection 2. WELL LOCATION: (Show sketch of the location below Nearest Town: Atkinson Municipal Other 700 East Church Street (Road Name and Numbers, Community, or Subdivision and Lot No.) 3. OWNER • Woodcock Oil Company Address 700 East Church Street (Street or Route No.) Atkinson. NC 28421 City or Town State Zip Code 4. DATE DRILLED 10/18/99 _ 5. TOTAL DEPTH 17.5' - 6. CUTTINGS COLLECTED YES NO X 7. DOES WELL REPLACE EXISTING WELL? YES NO x 8. STATIC WATER LEVEL Below Top of Casing: 9 Ft. 9. TOP OF CASING IS 0 Ft. Above Land Surface* "Top of casing terminated atlor below land surface requires a variance In accor- dance with 16A NCAC 2C.0118 10. YIELD (gpm): NIA 11. WATER ZONES (depth): 12. CHLORINATION: Type N/A 13. CASING Depth METHOD OF TEST N/A Surtcial Auuifer Amount N/A Wall Thickness Industrial Agricultural If Other, List use: County: Pender Diameter Or Weight/Ft. Material From 0. To 7.5 Ft. 2" From To Ft. From To Ft. 14. GROUT Depth From 3.5 To 5.5 Ft. From To Ft. From To Ft. 15. SCREEN SCH40 PVC Material Bentonite Method Poured Depth Diameter Slot Size Material From 7.5 To 17.5 Ft. 2" .010 PVC From To Ft. From To Ft. 16. SAND/GRAVEL PACK: Depth From 5.5 To 17.5 From To From To Ft. Size Material Ft. __.. Torpedo Sand Ft. DRILLING LOG From To SEE ATTACHED Monitoring DEPTH Formation Description If additional space is needed use back of form LOCATION SKETCH (Show direction and distance from at least two State Roads, or other map reference points) SEE ATTACHED 17. REMARKS: I DO HEREBY CERTIFY THAT THIS WELL WAS CONSTRUCTED IN ACCORDANCE WITH 15A NCAC 2C, WELL CONSTRUCTION STANDARDS, AND THAT A CO'y,OF THIS RECORD HAS BEEN PROVIDED TO THE WELL OWNER. Quad No: FOR OFFICE USE ONLY SIGNATURE OF PERSO Submit original to Division of Water quundwater Section within 30 days UCTING THE WELL DAT North Carolina - Department of Envwronement and Natural resources - Division of Water Quality - Groundwater Section 1936 Mail Service Center - Raleigh, N.C. 27699-1636- Phone (919) 733-3221 WELL CONSTRUCTION RECORD AMW 8 WELL CONTRACTOR: ARM's Waterworks - Don Cummings WELL CONTRACTOR CERTIFICATION #: 2412 STATE WELL CONSTRUCTION PERMIT #: 1. WELL USE (Check Applicable Box): Recovery Heat Pump Water injection Municipal Industrial Agricultural n Monitoring Other If Other, List use: 2. WELL LOCATION: (Show sketch of the location below Nearest Town: Atkinson County: Pender 700 East Church Street (Road Name and Numbers, Community, or Subdivision and Lot No.) 3. OWNER Woodcock Oil Company Address . 700 East Church Street (Street or Route No.) Atkinson. NC 28421 City or Town State 4. DATE DRILLED 10/18/99 5. TOTAL DEPTH 17.5' Zip Code 6. CUTTINGS COLLECTED YES NO X 7. DOES WELL REPLACE EXISTING WELL? YES NO x 8. STATIC WATER LEVEL Below Top of Casing: 10 Ft. 9. TOP OF CASING IS 0 Ft. Above Land Surface* "Top of casing terminated atfor below land surface requires a variance in accor- dance with 16A NCAC 2C.011B DRILLING LOG DEPTH From To Formation Description SEE ATTACHED 10. YIELD (gpm): NIA METHOD OF TEST N/A 11. WATER ZONES (depth): Surficial Aquifer If additional space is needed use back of form 12. CHLORINATION: Type WA Amount N/A 13. CASING Wall Thickness. Depth Diameter Or Weight/Ft. Material From 0 To 7.5 Ft. 2" SCH40 PVC From To Ft. From To Ft. 14. GROUT Depth Material Method From 3.5 To 5.5 Ft. Bentonite Poured From To Ft. From To Ft. 15. SCREEN Depth Diameter Slot Size Material From 7.5 To 17.5 Ft. 2" .010 PVC From _ To Ft. From To Ft. 16. SAND/GRAVEL PACK: Depth Size Material From 5.5 To 17.5 Ft. Torpedo Sand From To Ft. From To Ft. LOCATION .SKETCH (Show direction and distance from at least two State Roads, or other map reference points) SEE ATTACHED 17. REMARKS: • I DO HEREBY CERTIFY THAT THIS WELL WAS CONSTRUCTED IN ACCORDANCE WITH 15A NCAC 2C, WELL CONSTRUCTION STANDARDS, AND THAT A COPY THIS RECORD HAS BEEN PROVIDED TO THE WELL OWNER. FOR OFFICE USE ONLY Quad No: SIGNATURE OF PERSON 3-A-M o UCTING THE WELL D TE Submit original to Division of Water qua Groundwater Section within 30 days Noith Carolina - Department of Environement and Natural resources - Division of Water Quality - Groundwater Section 1936 Mail Service Center - Raleigh, N.C. 27699-1636- Phone (919) 733-3221 WELL CONSTRUCTION RECORD WELL CONTRACTOR: ARM's Waterworks - Don Cummings AMW-9 WELL CONTRACTOR CERTIFICATION #: 2412 STATE WELL CONSTRUCTION PERMIT #: 1. WELL USE (Check Applicable Box): Municipal Industrial ❑ Agricultural Recovery El Heat Pump Water injection — Other If Other, List use: 2. WELL LOCATION: (Show sketch of the location below Nearest Town: Atkinson _ County: Pender 700 East Church Street (Road Name and Numbers, Community, or Subdivision and Lot No.) 3. OWNER Woodcock Oil Company Address 700 East Church Street (Street or Route No.) Atkinson, NC 28421 City or Town State 4. DATE DRILLED 10/19/99 5. TOTAL DEPTH 19.5' Zip Code 6. CUTTINGS COLLECTED YES NO X 7. DOES WELL REPLACE EXISTING WELL? YES — NO x 8. STATIC WATER LEVEL Below Top of Casing: 10.5 Ft. 9. TOP OF CASING IS 0 Ft. Above Land Surface* *Top of casing terminated atlor below land surface requires a variance In accor- dance with 15A NCAC 2C.011 B 10. YIELD (gpm): N/A METHOD OF TEST N/A Monitoring DRILLING LOG DEPTH From To Formation Description SEE ATTACHED 11. WATER ZONES (depth): Surficial Aquifer If additional space is needed use back of form 12. CHLORINATION: Type N/A Amount N/A 13. CASING Wall Thickness LOCATION SKETCH Depth Diameter Or Weight/Ft. Material (Show direction and distance from at least two State Roads, or other map reference points) From 0 To 9.5 Ft. 2" SCH40 PVC From To Ft. From To Ft. 14. GROUT Depth Material Method From 3.5 To 7.5 Ft. Bentonite Poured From To Ft. From To Ft. 15. SCREEN Depth Diameter Slot Size Material From 9.5 To 19.5 Ft. 2" .010 PVC From To Ft. From To Ft. 16. SAND/GRAVEL PACK: Depth Size Material From 7.5 To 19.5 Ft.. Torpedo Sand From To Ft. From To • Ft. SEE ATTACHED 17. REMARKS: 1 DO HEREBY CERTIFY THAT THIS WELL WAS CONSTRUCTED IN ACCORDANCE WITH 15A NCAC 2C, WELL CONSTRUCTION STANDARDS, AND THAT A COPY OF THIS RECORD HAS BEEN PROVIDED TO THE WELL OWNER. Quad No: FOR OFFICE USE ONLY Submit original to Division of Water qual s 3 SIGNATURE OF PE SON COCTING THE WELL DAT roundwater Section within 30 days Notice of Intent to Construct or Operate Injection Wells Woodcock Oil Company, Atkinson, North Carolina APPENDIX C ACCESS AGREEMENT FROM SITE PROPERTY OWNER :4TC ENNINNNNENIAL• CE/7ECNNICAL INILNINC SCIENCES • NITENIALS 7ESTIIC UNDERGROUND STORAGE TANK SECTION February 10, 2020 Mr. Hassan Osman Hydrogeologist DWM/UST Section 1637 Mail Service Center Raleigh, NC 27699-1637 Dear Mr. Osman RE: Woodcock Oil Company 700 East Church Street Atkinson, Pender County, North Carolina Incident Number: 16996 I am/We are the owner(s) of a parcel of property, located at or near the incident in question, and hereby permit the Department of Environmental Quality (Department) or its contractor to enter upon said property for the purpose of conducting an assessment and/or remediation of the groundwater and/or soils under the authority of G.S. 143-21594G. I am/We are granting permission to the lands we own or control with the understanding that: 1. The investigation shall be conducted by the UST Section of the Department's Division of Waste Management or its contractor. 2. The costs of construction and maintenance of the site and access shall be borne by the Department or its contractor. The Department or its contractor shall protect and prevent damage to the surrounding lands. Any damages will be restored by the Department or its contractor to as close to the pre -work condition as practicably possible. 3. Unless otherwise agreed, the Department or its contractor shall have access to the site by the shortest feasible route to the nearest public road. The Department or its contractor will notify the land owners 48 hours prior to entry and may enter upon the land at reasonable times and have full right of access during the period of the investigation. 4. Any claims which may arise against the Department or its contractor shall be governed by Article 31 of Chapter 143 of the North Carolina General Statutes, Tort Claims Against State Departments and Agencies, and as otherwise provided by law. 5. The information derived from the investigation shall be made available to the owner upon request and is a public record, in accordance with G.S. 132-1. F 6. The activities to be carried out by the Department or its contractor are for the primary benefit of the Department and of the State of North Carolina. Any benefits accruing to the owner are incidental. The Department or its contractor is not and shall not be construed to be an agent, employee, or contractor of the landowner. No representations or warranties, either expressed or implied, have been made to me/by the Department, the State of North Carolina, or its/their contractor(s) regarding the results that may be obtained or the quality of work to be performed. I/We agree not to interfere with, remove or any ways damage the Department's well(s) or its contractor's well(s) and equipment during the investigation. Sincerely, Signature /(1q (-) PC` k- Type/Print Name of Owner or Agent 9fq q22-05K3 Phone Number tez L C/g' t Address 2-I City/State/Zip Code 2.0 Date RE: Woodcock Oil Company 700 East Church Street Atkinson, Pender County, North Carolina Incident Number: 16996 ATC ENVIRONMENTAL• GEOTECHNICAL BUILDING SCIENCES • MATERIALS TESTING 2725 East Millbrook Road Suite 121 Raleigh, NC 27604 Tel: 919-871-0999 Fax: 919-871-0335 www.atcgroupservices.com N.C. Engineering License No. C-1598 March 15, 2021 Ms. Shristi Shrestha North Carolina Department of Environmental Quality Division of Water Quality - Aquifer Protection Section, UIC Program 1636 Mail Service Center Raleigh, North Carolina 27699-1636 Reference: Notice of Intent to Construct or Operate Injection Wells Woodcock Oil Company 700 East Church Street Atkinson, Pender County, North Carolina NCDEQ Incident No. 16996 Dear Ms. Shrestha: RI ATC Associates of North Carolina, P.C. (ATC) has prepared the enclosed Notice of Intent to Construct or Operate Injection Wells on behalf of the North Carolina Department of Environmental Quality State -Lead Program. The permit application covers the performance of passive remediation in three monitoring wells associated with the above referenced site If you have questions or require additional information, please contact our office at (919) 871-0999. Sincerely, ATC Associates of North Carolina, P.C. Ashley M. Winkelman, P.G. Senior Project Manager cc: Hassan Osman, Hydrogeologist for NCDEQ Attachments Notice of Intent to Construct or Operate Injection Wells Woodcock Oil Company, Atkinson, North Carolina NOTICE OF INTENT FORM ATC E.RON•ENIAL • OEORCMICAI NII0.61s6iCIENLCi• k11ENatiiE511116 NC Department of Environmental Quality — Division of Water Resources (DWR) NOTIFICATION OF INTENT (NOI) TO CONSTRUCT OR OPERATE INJECTION WELLS The following are `permitted by rule" and do not require an individual permit when constructed in accordance with the rules of 15A NCAC 02C.0200 (NOTE: This form must be received at least 14 DAYS prior to injection) AQUIFER TEST WELLS (15A NCAC 02C .0220) These wells are used to inject uncontaminated fluid into an aquifer to determine aquifer hydraulic characteristics. IN SITU REMEDIATION (15A NCAC 02C .0225) or TRACER WELLS (15A NCAC 02C .0229): 1) Passive Injection Systems - In -well delivery systems to diffuse injectants into the subsurface. Examples include ORC socks, iSOC systems, and other gas infusion methods (Note: Injection Event Records (IER) do not need to be submitted for replacement of each sock used in ORC systems). 2) Small -Scale Injection Operations — Injection wells located within a land surface area not to exceed 10,000 square feet for the purpose of soil or groundwater remediation or tracer tests. An individual permit shall be required for test or treatment areas exceeding 10,000 square feet. 3) Pilot Tests - Preliminary studies conducted for the purpose of evaluating the technical feasibility of a remediation strategy in order to develop a full scale remediation plan for future implementation, and where the surface area of the injection zone wells is located within an area that does not exceed five percent of the land surface above the known extent of groundwater contamination. An individual permit shall be required to conduct more than one pilot test on any separate groundwater contaminant plume. 4) Air Injection Wells - Used to inject ambient air to enhance in -situ treatment of soil or groundwater. 5) In -Situ Thermal Wells (IST) — Used to `heat' contaminated groundwater to enhance remediation Print Clearly or Type Information. Illegible Submittals Will Be Returned as Incomplete. DATE: March 15 , 20_21 PERMIT NO. (to be filled in by DWR) NOTE- If this NOI is being submitted as notification of a modification of a previously issued NOI for this site (e.g., different injection wells, plume, additives, etc.) and still meets the deemed permitted by rule criteria, provide the previously assigned permit tracking number and any needed relevant information to assess and approve injection: A. B. Permit No. WI Issued Date: WELL TYPE TO BE CONSTRUCTED OR OPERATED (1) Air Injection Well Complete sections B through F, J, M (2) Aquifer Test Well .Complete sections B through F, J, M (3) X Passive Injection System ..Complete sections B through F, H-M (4) Small -Scale Injection Operation Complete sections B through M (5) Pilot Test Complete sections B through M (6) In -Situ Thermal (IST) Well Complete all sections except K STATUS OF WELL OWNER: State Government Deemed Permitted GW Remediation NOI Rev. 2-14-2020 Page 1 C. WELL OWNER(S) — State name of Business/Agency, and Name and Title of person delegated authority to sign on behalf of the business or agency: Name: Hassan Osman — Hydrogeologist, North Carolina Department of Environmental Quality Mailing Address: 1646 Mail Service Center City: Raleigh State: NC Zip Code: 27699-1646 County: Wake Day Tele No.: 919-707-8167 Cell No.: Not Available EMAIL Address: hassan.osman@ncdenr.gov Fax No.: Not Available D. PROPERTY OWNER(S) (if different than well owner/applicant) Name and Title: Maulin Patel Company Name Not Applicable Mailing Address: 126 W. Church St City: Atkinson State: NC Zip Code: 28421 County: Pender Day Tele No.: 919-922-0563 Cell No.: Not Available EMAIL Address: Not Available Fax No.: Not Available E. PROJECT CONTACT (Typically Environmental Consulting/Engineering Firm) Name: Ashley M. Winkelman — ATC Associates of North Carolina, P.C. Mailing Address: 2725 E. Millbrook Road, Suite 121 City: Raleigh State: NC_ Zip Code:27604 County: Wake Day Tele No.: 919-871-0999 Cell No.: 919-830-3576 EMAIL Address: ashley.winkelman@atcgs.com F. PHYSICAL LOCATION OF WELL SITE (1) Facility Name & Address: Woodcock Oil Company 700 East Church Street Fax No.: 737-207-8261 City: Atkinson County: Pender Zip Code: 28421 (2) Geographic Coordinates: Latitude**: " or 34 °.53189 Longitude**: " or 78 °. 16374 Reference Datum: WGS84 Accuracy: 10-meter Method of Collection: DOQ — Acme Mapper 2.2 **FOR AIR INJECTION AND AQUIFER TEST WELLS ONLY: A FACILITY SITE MAP WITH PROPERTY BOUNDARIES MAY BE SUBMITTED IN LIEU OF GEOGRAPHIC COORDINATES. G. TREATMENT AREA Land surface area of contaminant plume: square feet Land surface area of inj. well network: square feet (< 10,000 ft2 for small-scale injections) Percent of contaminant plume area to be treated: (must be < 5% of plume for pilot test injections) Deemed Permitted GW Remediation NOI Rev. 2-14-2020 Page 2 H. INJECTION ZONE MAPS — Attach the following to the notification. (1) Contaminant plume map(s) with isoconcentration lines that show the horizontal extent of the contaminant plume in soil and groundwater, existing and proposed monitoring wells, and existing and proposed injection wells; and Included in the Figures section. (2) Cross-section(s) to the known or projected depth of contamination that show the horizontal and vertical extent of the contaminant plume in soil and groundwater, changes in lithology, existing and proposed monitoring wells, and existing and proposed injection wells. (3) Included in the Figures section. Potentiometric surface map(s) indicating the rate and direction of groundwater movement, plus existing and proposed wells. Included in the Figures section. DESCRIPTION OF PROPOSED INJECTION ACTIVITIES AT THE SITE — Provide a brief narrative regarding the cause of the contamination, and purpose, scope, goals of the proposed injection activity: ATC will install three Provect ORS sleeves each in monitoring wells AMW-4, AMW-8, and AMW-9 in order to aide in natural attenuation and reduce compounds concentrations to below the North Carolina Groundwater Quality Standards (2L Standards). Based on the most recent sampling event performed in May 2020, the following compounds exceeded the 2L Standards: benzene and naphthalene. The sleeves come in 3-foot sections. ATC will install three 3-foot sections at the base of the wells, across the well screen. The socks will release oxidizing solids into the groundwater for approximately 6 months, at which point the chemicals in the socks will have depleted. J. WELL CONSTRUCTION DATA (1) No. of injection wells: Proposed 3 Existing (provide NC Well Construction Record (GW-1) for each well) Included in Appendix B (2) Appx. injection depths (BLS): 8.5-19.5 (3) For Proposed wells or Existing wells not having GW-ls, provide well construction details for each injection well in a diagram or table format. A single diagram or line in a table can be used for multiple wells with the same construction details. Well construction details shall include the following (indicate if construction is proposed or as -built): (a) Well type as permanent, Geoprobe/DPT, or subsurface distribution infiltration gallery (b) Depth below land surface of casing, each grout type and depth, screen, and sand pack (c) Well contractor name and certification number K. INJECTION SUMMARY NOTE: Only injectants approved by the epidemiology section of the NC Division of Public Health, Department of Health and Human Services can be injected. Approved injectants can be found online at http: //deq. nc. gov/about/divisions/water-resources/water-resources-permits/wastewater-branch/ground-water- protection/ground-water-approved-injectants. All other substances must be reviewed by the DHHSprior to use. Deemed Permitted GW Remediation NOI Rev. 2-14-2020 Page 3 Contact the UIC Program for more info if you wish to get approval for a different additive. However, please note it may take 3 months or longer. Injectant: Provect ORS Sleeves Total Amt. to be injected (gal)/event: 3,114 in3 (volume of' sleeves) Amt. Water to be injected (gal/event) : Total Amt. to be injected (gal/event): No. of separate injection events:1 N/A 3,114 in3 (volume of sleeves) Est. Total Amt. to be injected (gal): 3,114 in3 (volume of sleeves) Source of Water (if applicable): N/A L. MONITORING PLAN — Describe below or in separate attachment a monitoring plan to be used to determine if violations of groundwater quality standards specified in Subchapter 02L result from the injection activity. Approximately 6 months after the installation of the Provect ORS sleeves, ATC will collect a sample from the wells for analysis of volatile organic compounds by EPA Method 6200B. The samples will be shipped to Pace Analytical in Mt. Juliet, Tennessee. ATC will also measure dissolved oxygen, conductivity, temperature, pH, and oxygen reduction potential during the sampling event. M. SIGNATURE OF APPLICANT AND PROPERTY OWNER Well Owner/Applicant: "I hereby cent , under penalty of lcnv, that I am familiar with the information submitted in this document and all attachments thereto and that, based on my inquiry of those individuals immediately responsible for obtaining said information, I believe that the information is true, accurate and complete. I am aware that there are significant penalties, including the possibility of fines and imprisonment, for submitting false information. I agree to construct, operate, maintain, repair, and if applicable, abandon the injection well and all related appurtenances in accordance with the 15A NCAC 02C 0200 Rules." Ashley Winkelman on behalf of Hassan Osman, NCDEQ Signature of Applicant Print or Type Full Name and Title Property Owner (if the property is not owned by the Well Owner/Applicant): "As owner of the property on which the injection well(s) are to be constructed and operated, I hereby consent to allow the applicant to construct each injection well as outlined in this application and agree that it shall be the responsibility of the applicant to ensure that the injection well(s) conform to the Well Construction Standards (15A NCAC 02C .0200)." "Owner" means any person who holds the fee or other property rights in the well being constructed. A well is real property and its construction on land shall be deemed to vest ownership in the land owner, in the absence of contrary agreement in writing. See Appendix C Maulin Patel Signature* of Property Owner (if different from applicant) Print or Type Full Name and Title *An access agreement between the applicant and property owner may be submitted in lieu of a signature on this form. Deemed Permitted GW Remediation NOI Rev. 2-14-2020 Page 4 Please send 1 (one) hard color copy of this NOI along with a copy on an attached CD or Flash Drive at least two (2) weeks prior to injection to: DWR — UIC Program 1636 Mail Service Center Raleigh, NC 27699-1636 Telephone: (919) 707-9000 Deemed Permitted GW Remediation NOI Rev. 2-14-2020 Page 5 Ashley Winkelman From: Osman, Hassan <hassan.osman@ncdenr.gov> Sent: Monday, March 15, 2021 11:09 AM To: Ashley Winkelman Subject: RE: [External] #16996 Woodcock Oil NOI Hassan Osman from UST Section, Trust Fund Brach, I am giving a permission ATC to submit NOI on behalf of UST Section, Trust Fund Brach. If you have any questions you can contact at (919) 707-8167. Thanks Hassan From: Ashley Winkelman <ashley.winkelman@atcgs.com> Sent: Monday, March 15, 2021 10:59 AM To: Osman, Hassan <hassan.osman@ncdenr.gov> Subject: [External] #16996 Woodcock Oil NOI CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Hey Hassan, I'm getting ready to submit the Notice of Intent for the ORS Sleeve installation at Woodcock Oil. Can you respond to this email giving me permission to sign the NOI on your behalf? Ashley M. Winkelman PGI SENIOR PROJECT MANAGER 1 ATC Group Services LLC Direct +1 919 573 1206 I Cell +1 919 830 3576 ETC 2725 E. Millbrook Road, Suite 121 1 Raleigh, NC 27604 Fax +1 919 871 0335 I ashley.winkelman@atcgs.com I www.atcgroupservices.com This email and its attachments may contain confidential and/or privileged information for the sole use of the intended recipient(s). If you are not the intended recipient, any use, distribution or copying of the information contained in this email and its attachments is strictly prohibited. If you have received this email in error, please notify the sender by replying to this message and immediately delete and destroy any copies of this email and any attachments. The views or opinions expressed are the author's own and may not reflect the views or opinions of ATC. 1 Notice of Intent to Construct or Operate Injection Wells Woodcock Oil Company, Atkinson, North Carolina FIGURES ATC E.RON•ENIAL • OEORCMICAI NII0.61s6iCIENLCi• k11ENatiiE511116 H.\2020\OTHER OFFICES \NORTH CAROLINA\NCDEQ-STATE LEAD\WOODCOCK OIL\SLP1699602-BENZ.DWG. FIG5 AMW-1 NS a. \A 1 i i `' .. \ ` a \ ' \ �▪ � NA \ _ • s rt.„,,.--\ ,\ ( 17 MW-3R -� N. \ \OO \ <0.50 A r/ \ • \ E NS A AMW-2\ \\# aooP�/ % NS j, I \ \A \\ NA\\ FORMER AST \\ NA\ LOCATION \ % \ \ \ LEGEND: AMW-11 MONITORING WELL 5).50 Well Identification Benzene Concentration (pg/L) T-1 TYPE III MONITORING WELL �- Well Identification CCDW-1 WATER SUPPLY WELL �- Well Identification CCDW-2 ABANDONED WATER SUPPLY WELL Well Identification — SITE PROPERTY LINE PARCEL LINE FORMER PRODUCT PIPING WATER LINE O FORMER DIESEL DISPENSER O FORMER KEROSENE DISPENSER ▪ FORMER GASOLINE DISPENSER BENZENE ISOCONCENTRATION CONTOUR (DASHED WHERE INFERRED) (Ng/L) NOTE: ALL LOCATIONS ARE APPROXIMATE P—P— W—w— i AM W-7 NS RESIDENTIAL i T-14- \ .* C. o NS // / ' ; \ 7N1m-p 21 J \\ AMW-8 6.9J 1 L WSW-1 * " AMW-10 <0.50 w WSW-3 t 5 4 FORMER UST BASIN i AMW-4 19 10 \ \- "=^:-v! w--WSW- 3A RESIDENTIAL L. w WSW-2* (ABANDONED) AM W-6 NS 111 # 4� .1 4 AMW-12 <0.50 AMW-5 —� 14 • F - J y /10 �AM M 1111. '1 -Ploh +1. 1 .-� T .. r • 1AM S 17 ,R ` - - y.��� _4ifr '' ▪ .ti AMW-11 11 <0.50 ti JAMW-16 0_50 ' ` IJ• ▪ • • r LIP AMW-15 NS I � YAMW-14 <O.F iF r k • 1, 3 4 { .* - N r 40 4 • L A SLP1699602 0 N t as F C 0 0 a 0 0 O m d 3 9 w 0z ni rivlri z BENZENE ISOCONCENTRATION CONTOUR MAP WOODCOCK OIL CO. = INCIDENT #16996 700 EAST CHURCH STREET ATKINSON, PENDER COUNTY, NORTH CAROLINA LL >- cn N a tl W z a W Z W 04 �U 0_ >- U WO z Z om 00<< U Z 10 20 30 40 SCALE: 1" = 40' Date 6/20 Scale' AS SHOWN Figure: H.\2020\OTHER OFFICES \NORTH CAROLINA\NCDEQ-STATE LEAD\WOODCOCK OIL\SLP1699602-NAP.DWG. FIG6 AMW-8 8.7 \ LEGEND: AMW-11 MONITORING WELL +<1.0 Well Identification Naphthalene Concentration (pg/L) T-1 TYPE III MONITORING WELL �— Well Identification CCDW-1 WATER SUPPLY WELL �— Well Identification CCDW-2 ABANDONED WATER SUPPLY WELL Well Identification ---- SITE PROPERTY LINE PARCEL LINE P P— FORMER PRODUCT PIPING w— WATER LINE FORMER DIESEL DISPENSER FORMER KEROSENE DISPENSER ▪ FORMER GASOLINE DISPENSER NAPHTHALENE ISOCONCENTRATION CONTOUR (DASHED WHERE INFERRED) (Ng/L) NOTE: ALL LOCATIONS ARE APPROXIMATE (-' • T-14- \ \\ cN o NS \\ \ �m1' MW-17 \TNmi3 2.0 \ \1- f4NN4 / \A \' , OtiVAM<1.W-3R \ 0 NS \ f- - Ci FOP, /L-ir4Li AMW-10 <1.0 • • •/ w w w� —vd w • WSW-3A WSW-3 \ AM W-7 NS - AMW-1 NS \ r \ ' • RESIDENTIAL ▪ 111111 RESIDENTIAL a • .-I 2 f P AMW-11 <1.0 r • y WSW-2* (ABANDONED) AM W-6 NS AMW-5 <1.0 'AMW-16� m h 1*0 ., •. AMW-12 10- 0.22J AP." .4 i•1. 41-24 • t - 4— ▪ OE -. • • + • }� t -..• + I.i l • 4r ~ • L� .4 4 ,.i �� ▪ 7i _.1 • it- . I -a .I.I:41- 1".` .8 I~ •,.I N. 1, lis '1 +AM NSS iglia 4 FIP -11 • r ti +AMS17 + • a 4•+ YAMW-14 Iifftrivo -A NS-15 . r it *r Lb I � r 40 • N L r. { 10 20 30 40 SCALE: 1" = 40' Project Number: SLP1699602 0 0 N a E" 0 0 0 0 0 m d 3 9 w 1- 0 — N C7 V If) z NAPHTHALENE ISOCONCENTRATION CONTOUR MAP WOODCOCK OIL CO. - INCIDENT #16996 700 EAST CHURCH STREET ATKINSON, PENDER COUNTY, NORTH CAROLINA LL >- cn N a w z a w F Z w 04 F- U 0) _ >- U 0 < Z Z_ E rn 0< U Z Date 6/20 Scale: AS SHOWN Figure: GRAVEL AREA Former UST Basin DL-3 P-1 (10_:) '• S-8 Er ' �/ s-6r Former S-7�' ,DL-2 1 Gasoline PAVED 1 AREA o S 5 ♦ STORE euser ps S-1 S-2 — i S-3 7s4 LB 1 DW-1 LEGEND • Soil Sample Location * Domestic Well Location Former Kerosene Dispenser Dispenser Line Trench Excavation X X I I ILA Former Diesel DL-6 I I L-3 and Kerosene \ \ � Dispensers \ \ L-8 i i L-4 -\• 411 • AST-1 I Former DL 7 �' L-7 L-5 1 Loading AST-2 I • Rack ` • L-6 A:3 1 AST-4 • 1 1 1 1 I DL-8 \• /,,,..,/ii/.iiii'/ FORMER * OFFICE / ///7//////////% % 1 DL-9 DL-10W 0 • AST-6• DL-10 i• Approx. Limits Of Excavation AST-5 • Former AST Basin 71(ke. pplied Resource Management PC P.O. Box 882, Hampstead, NC 28443 (910) 270-2919 FAX 270-2988 TITLE: SITE MAP WITH ABATEMENT SOIL SAMPLE LOCATIONS JOB: 9914 SCALE: 1"=40' DATE: 1 /9/03 DRAWN BY: JLC/EFC FIGURE: TABLE 1 ABATEMENT SOIL SAMPLE RESULTS SUMMARY EPA METHODS 3550 and 5030 FORMER WOODCOCK OIL COMPANY ATKINSON, NORTH CAROLINA Concentrations in Parts Per Million (mg/Kg) SAMPLE LOCATION EPA METHOD FIELD IDENTIFICATION MAP IDENTIFICATION SAMPLE DATE SAMPLE DEPTH 3550 5030 Pit 1 P-1 8/6/02 6' <10 <5 Pit 1 P-1 8/6/02 10' <10 <5 SW-1 S-1 8/6/02 12' <10 <5 SSW-1 S-2 8/8/02 8' <10 296 SSW-2 S-3 8/12/02 8' <10 <5 EESW-1 S-4 8/12/02 6' <10 <5 CWSW-1 S-5 8/8/02 8' <10 39.7 NWESW-1 S-6 8/9/02 8' <10 <5 NECSW-1 S-7 8/9/02 8' <10 <5 NEESW-1 S-8 8/9/02 8' <10 <5 DL-2 DL-2 8/7/02 4' <10 <5 DL-3 DL-3 8/7/02 4' <10 <5 ESWDL-4 DL-4 8/7/02 8-9' <10 <5 DL-5 DL-5 8/12/02 4' <10 <5 DL-6 DL-6 8/12/02 4' <10 <5 DL-7 DL-7 8/13/02 4' <10 <5 DL-8 DL-8 8/13/02 4' <10 <5 DL-9 DL-9 8/13/02 4' <10 <5 DL-10 DL-10 8/13/02 4' <10 <5 DL-10W DL-10W 8/13/02 6' <10 <5 LRNSW-3 L-1 8/12/02 6-8' <10 <5 LRNSW-2 L-2 8/12/02 6-8' <10 <5 LRNSW-1 L-3 8/12/02 5' 923 <5 LRESW-1 L-4 8/12/02 5' <10 <5 LRESW-2 L-5 8/12/02 6' <10 <5 LRSSW-1 L-6 8/12/02 8' <10 <5 LRWSW-1 L-7 8/12/02 8' <10 <5 LRSW-2 L-8 8/12/02 8' 11.6 <5 AST-1 AST-1 8/12/02 3' <10 <5 AST-2 AST-2 8/12/02 3' <10 <5 AST-3 AST-3 8/12/02 3' <10 <5 AST-4 AST-4 8/12/02 2' <10 <5 AST-5 AST-5 8/12/02 2' <10 <5 AST-6 AST-6 8/12/02 2' <10 <5 Shaded areas represent non compliant hydrocarbon concentrations. Noncompliant defined as 40 mg/kg for EPA Method 3550, and 10 mg/kg for EPA Method 5030. B AMW-10 (99.18) LEGEND GRAVEL AREA _ 1 Former 4100.00) UST Basin Former • Kerosene • e Dispenser 7) AMW-9 • (99.40) AMW-2s (99.10) LB1 DW-1 i FORMER *OFFICE • S-1 B-6• 53 AMW-7 (98.33) B' GRASSED AREA Diesel and Kerosene Dispensers •B-4 Diesel AST Dies OAST Gas AST Gas AST • B-3 AMW-6 (96.42) S3•AMW-5� Former r • S-2 (96.57) UST Basinn" ' B-5A AMW-4 (98.65) • Exploratory Boring Location O Type II Monitoring Well Location & Type III Monitoring Well Location * Approximate Domestic Well Location (94.15) Top of Casing Elevation (in feet) Gas AST • B-5 CCDW-2 • AMW-11 (98.15) AMW-12Q (95.14) * CCDW-1 A pplied Resource Management f C (9 P.O. Box 882. Ho,w teas. NC 28443 10)270-2919 FAX 270-2988 TITLE: SITE MAP WITI-I AQUIFER TRANSECT LOCATIONS JOB: 9914 SCALE: 1 " = 40' DATE: 5/16/00 DRAWN BY: DHC FIGIJRF: 5 0 n z ,V-V 1O3SNV2112133If10V os 120.00 100.00 80.00 60.00 40.00 A AMW-8 8-2 AMW-3 T-2 AMW-9 AMW-2 8-4 B-3 (99.57') (99.96') (100.07') (99,40) (99.10') LEGEND 20.00 — SP - Poorly graded sands or gravelly sands, little or no fines. 00,00 CH - Inorganic clays of high plasticity, fat clays. • . SC - Clayey sands, sand -clay mixtures. V Groundwater table elevation r — as of 3/21 /00. A' AMW-12 (95.14') Scale: 1 "=40' horiz. 1 "=20' vert. 40 80 120 160 200 240 280 euWW aa,inoGapaij 0 co o D m 0 0 0 z n z co ,9-9133SNV2112J3difl©V m C m 120.00 100.00 80.00 60.00 40.00 20,00 --I 00.00 B AMW-10 (99.18') T-2 AMW-1 (100.07') (99.05') LEGEND SP - Poorly graded sands or gravelly sands, little or no fines. CH - Inorganic clays of high plasticity, fat clays. • SC - Clayey sands, sand -clay mixtures. — Groundwater table elevation as of 3/21 /00, 40 80 120 B' AMW-7 (98.33') Scale: 1 "=40' horiz, 1 "=20' vert, I I I I I 160 200 240 280 H.\2020\OTHER OFFICES \NORTH CAROLINA\NCDEQ-STATE LEAD\WOODCOCK OIL\SLP1699602-POT.DWG. FIG4 AMW-8 89.11 LEGEND: AMW-11 MONITORING WELL 8.32 Well Identification Relative Groundwater Elevation (ft) T-1 TYPE III MONITORING WELL — — Well Identification CCDW-1 WATER SUPPLY WELL �— Well Identification CCDW-2 ABANDONED WATER SUPPLY WELL 7 Well Identification — p—p- - ww - w— ❑K O — 89.0— SITE PROPERTY LINE PARCEL LINE FORMER PRODUCT PIPING WATER LINE FORMER DIESEL DISPENSER FORMER KEROSENE DISPENSER FORMER GASOLINE DISPENSER GROUNDWATER ELEVATION CONTOUR (DASHED WHERE INFERRED) GROUNDWATER FLOW DIRECTION NOTE: ALL LOCATIONS ARE APPROXIMATE AMW-3R 91.87 STOR AMW-1 88.53 t RESIDENTIAL RESIDENTIAL 1 AMW-16 -N.87 3 L WSW-2* (ABANDONED) AMW-12 86.92 AMW-13 10- NM . 411.110 _AMW-15 NM rt • AMW-17 NM tMW-14 864h+■ iff OP r tee, ■ 40 41a- i 10 20 30 40 SCALE: 1" = 40' 1 u- >- cn M 4- a a W z u< W a co cU >- YF U � WU a Z Z_ E rn o °oaa U Z Project Number: Date 6/20 SLP1699602 GROUNDWATER ELEVATION CONTOUR MAP Scale: AS SHOWN Figure: WOODCOCK OIL CO. - INCIDENT #16996 700 EAST CHURCH STREET ATKINSON, PENDER COUNTY, NORTH CAROLINA Notice of Intent to Construct or Operate Injection Wells Woodcock Oil Company, Atkinson, North Carolina APPENDIX A MSDS FORM ATC En1RON•ENIAL • OEORCMICAI NII0.61s6iCIENLCi• k11EN14iiE511116 * rovectus El*1VIRONMENTAL PRODUCTS MATERIAL SAFETY DATA SHEET: PROVECT-ORS Page: 1 of 5 1. PRODUCT IDENTIFICATION: PROVECT-ORS PRODUCT USE: Soil and water treatment. MANUFACTURER: EMERGENCY PHONE: PROVECTUS ENVIRONMENTAL 2871 W. Forest Rd., Suite 2 Freeport, IL 61032 USA: ($15) 650-2230 TRANSPORTATION OF DANGEROUS GOOD CLASSIFICATION: Oxidizing Solid, n.o.s. (Calcium Peroxide), Class 5.1, PG II, UN1479 WHMIS CLASSIFICATION: Oxidizer 2. COMPOSITION/INFORMATION ON INGREDIENTS Ingredients Calcium Peroxide Inorganic Nutrients 3. PHYSICAL DATA Chemical Formula CaO2 CAS No. Percentage 1305-79-9 75%-85% 15%-25% Appearance White & brown granules Physical state Solid Odor threshold None Bulk Density 500-650g/L Solubility in Water Insoluble pH —11 Decomposition Temperature Self -accelerating decomposition with oxygen release starting from 275 degrees Celsius 4. HAZARDS IDENTIFICATION Emergency overview Oxidizing agent, contact with other material may cause fire. Under fire conditions this material may decompose and release oxygen that intensifies fire. This product contains <1% non -respirable crystalline silica. The NTP and OSHA have not classified non -respirable crystalline silica as carcinogenic. Long term exposure to hazardous levels of respirable silica dusts can cause lung disease (silicosis). ORS does not contain respirable crystalline silica. Potential Health Effects: • General Irritating to mucous membrane and eyes. rovectus ENVIRONMENTAI. PRODUCTS" MATERIAL SAFETY DATA SHEET: PROVECT-ORS Page: 2 of 5 • Inhalation Irritating to respiratory tract. Long term inhalation of elevated levels may cause lung disease (silicosis). • Eye contact May cause irritation to the eyes; Risks of serious or permanent eye lesions. • Skin contact May cause skin irritation. • Ingestion Irritation of the mouth and throat with nausea and vomiting. 5. FIRST AID MEASURES • Inhalation Remove affected person to fresh air. Seek medical attention if effects persist. • Eye contact Flush eyes with running water for at least 15 minutes with eyelids held open. Seek specialist advice. • Skin contact Wash affected skin with soap and mild detergent and large amounts of water. • Ingestion If the person is conscious and not convulsing, give 2-4 cupfuls of water to dilute the chemical and seek medical attention immediately. Do not induce vomiting. 6. FIRE FIGHTING MEASURE Flash Point • Not applicable Flammability • Not applicable Ignition Temperature • Not applicable Danger of Explosion • Non -explosive Extinguishing Media • Water Fire Hazards • Oxidizer. Storage vessels involved in a fire may vent gas or rupture due to internal pressure. Damp material may decompose exothermically and ignite combustibles. Oxygen release due to exothermic decomposition may support combustion. May ignite other combustible materials. Avoid contact with incompatible materials such as heavy metals, reducing agents, acids, bases, rovectus ENVIRONMENTAL PRODUCTS} MATERIAL SAFETY DATA SHEET: PROVECT-ORS Page: 3 of 5 combustible (wood, papers, cloths etc.) Thermal decomposition releases oxygen and heat. Pressure bursts may occur due to gas evolution. Pressurization if confined when heated or decomposing. Containers may burst violently. Fire Fighting Measures • Evacuate all non -essential personnel • Wear protective clothing and self-contained breathing apparatus. • Remain upwind of fire to avoid hazardous vapors and decomposition products. • Use water spray to cool fire- exposed containers. 7. ACCIDENTAL RELEASE MEASURES Spill Clean-up Procedure • Oxidizer. Eliminate all sources of ignition. Evacuate unprotected personnel from equipment recommendations found in Section 9. Never exceed any occupational exposure limit. • Shovel or sweep material into plastic bags or vented containers for disposal. Do not return spilled or contaminated material to inventory. Avoid making dust. • Flush remaining area with water to remove trace residue and dispose of properly. Avoid direct discharge to sewers and surface waters. Notify authorities if entry occurs. • Do not touch or walk through spilled material. Keep away from combustibles (wood, paper, oils, etc.). Do not return product to container because of risk of contamination. 8. HANDLING AND STORAGE Storage • Oxidizer. Store in a cool, well -ventilated area away from all source of ignition and out of direct sunlight. Store in a dry location away from heat. • Keep away from incompatible materials. Keep containers tightly closed. Do not store in unlabeled or mislabeled containers. • Protect from moisture. Do not store near combustible materials. Keep containers well sealed. Ensure pressure relief and adequate ventilation. • Store separately from organics and reducing materials. Avoid contamination that may lead to decomposition. Handling • Avoid contact with eyes, skin, and clothing. Use with adequate ventilation. • Do not swallow. Avoid breathing vapors, mists, or dust. Do not eat, drink, or smoke in work area. • Prevent contact with combustible or organic materials. • Label containers and keep them tightly closed when not in use. • Wash thoroughly after handling. * rovers ENVIRONMENTAL PRODUCTS' MATERIAL SAFETY DATA SHEET: PROVECT-ORS Page: 4 of 5 9. EXPOSURE CONTROLS/PERSONAL PROTECTION Engineering Controls • General room ventilation is required. Local exhaust ventilation, process enclosures or other engineers controls may be needed to maintain airborne levels below recommended exposure limits. Avoid creating dust or mist. Maintain adequate ventilation. Do not use in closed or confined spaces. Keep levels below exposure limits. To determine exposure limits, monitoring should be performed regularly. Respiratory Protection • For many condition, no respiratory protection may be needed; however, in dusty or unknown atmospheres or when exposures exceed limit values, wear a NIOSH approved respirator. Eye/Face Protection • Wear chemical safety goggles and a full face shield while handling this product. Skin Protection • Prevent contact with this product. Wear gloves and protective clothing depending on condition of use. Protective gloves: Chemical -resistant (Recommended materials: PVC, neoprene or rubber) Other Protective Equipment • Eye -wash station • Safety shower • Impervious clothing • Rubber boots General Hygiene Considerations • Wash with soap and water before meal times and at the end of each work shift. Good manufacturing practices require gross amounts of any chemical removed from skin as soon as practical, especially before eating or smoking. 10. STABILITY AND REACTIVITY Stability • Stable under normal conditions Condition to Avoid • Water • Acids • Bases • Salts of heavy metals • Reducing agents • Organic materials • Flammable substances Hazardous Decomposition Products • Oxygen which supports combustion rovectus ENVIRONMENTAL PRODUCTS} MATERIAL SAFETY DATA SHEET: PROVECT-ORS Page: 5 of 5 11. TOXICOLOGICAL INFORMATION • LD50 Oral: Min.2000 mg/kg, rat • LD50 Dermal: Min. 2000mg/kg, rat • LD50 Inhalation: Min. 4580 mg/kg, rat 12. ECOLOGICAL INFORMATION Ecotoxicological Information • Hazards for the environment is limited due to the product properties of no bioaccumulation, weak solubility and precipitation in aquatic environment. Chemical Fate Information • As indicated by chemical properties oxygen is released into the environment. 13. DISPOSAL CONSIDERATIONS Waste Treatment • Dispose of in an approved waste facility operated by an authorized contractor in compliance with local regulations. Package Treatment • The empty and clean containers are to be recycled or disposed of in conformity with local regulations. 14. TRANSPORT INFORMATION • Proper Shipping Name: EHC-O • Hazard Class: 5.1 • Labels: 5.1 (Oxidizer) • Packing Group: II 15. REGULATORY INFORMATION • SARA Section Yes • SARA (313) Chemicals No • EPA TSCA Inventory Appears • Canadian WHMIS Classification C, D2B • Canadian DSL Appears • EINECS Inventory Appears Notice of Intent to Construct or Operate Injection Wells Woodcock Oil Company, Atkinson, North Carolina APPENDIX B MONITORING WELL CONSTRUCTION DETAILS ATC En1RON•ENIAL • OEORCMICAI NII0.61s6iCIENLCi• k11EN14iiE511116 North Carolina - Department of Environement and Natural resources - Division of Water Quality - Groundwater Section 1936 Mail Service Center - Raleigh, N.C. 27699-1636- Phone (919) 733-3221 WELL CONSTRUCTION RECORD AMW-4 WELL CONTRACTOR: ARM's Waterworks - Don Cummings WELL CONTRACTOR CERTIFICATION #: 2412 STATE WELL CONSTRUCTION PERMIT #: 1. WELL USE (Check Applicable Box): Municipal Industrial Agricultural a Monitoring El Recovery El Heat Pump Water injection Other If Other, List use: 2. WELL LOCATION: (Show sketch of the location below Nearest Town: Atkinson County: Pender 700 East Church Street (Road Name and Numbers, Community, or Subdivision and Lot No.) 3. OWNER Woodcock Oil Company Address 700 East Church Street (Street or Route No.) Atkinson, NC 28421 City or Town State Zip Code 4. DATE DRILLED 10/18/99 5. TOTAL DEPTH 17.5' 6. CUTTINGS COLLECTED YES NO X 7. DOES WELL REPLACE EXISTING WELL? YES _ NO x 8. STATIC WATER LEVEL Below Top of Casing: 9 Ft. 9. TOP OF CASING IS 0 Ft. Above Land Surface* 'Top of casing terminated atior below land surface requires a variance In accor- dance with 16A NCAC 2C.0118 10. YIELD (gpm): N/A METHOD OF TEST N/A DRILLING LOG DEPTH From To SEE ATTACHED Formation Description 11. WATER ZONES (depth): Surficial Aquifer If additional space is needed use back of form 12. CHLORINATION: Type N/A Amount N/A 13. CASING Wall Thickness LOCATION SKETCH Depth Diameter Or Weight/Ft. Material (Show direction and distance from at least two State Roads, or other map reference points) From To 7.5 Ft. 2" SCH40 PVC From To Ft. From To Ft. 14. GROUT Depth Material Method From 3.5 To 5.5 Ft. Bentonite Poured From To Ft. From To Ft. 15. SCREEN Depth Diameter Slot Size Material From 7.5 To 17.5 Ft. 2" .010 PVC From To Ft. From To Ft. 16. SAND/GRAVEL PACK: Depth Size Material From 5.5 To 17.5 Ft. Torpedo Sand From To Ft. From To Ft. SEE ATTACHED 17. REMARKS: I DO HEREBY CERTIFY THAT THIS WELL WAS CONSTRUCTED IN ACCORDANCE WITH 15A NCAC 2C, WELL CONSTRUCTION STANDARDS, AND THAT A CO OF THIS RECORD HAS BEEN PROVIDED TO THE WELL OWNER. 99-ieje) UCTING THE WELL DAT Quad No: FOR OFFICE USE ONLY SIGNATURE OF PERSO Submit original to Division of Water qu7" 'undwater Section within 30 days North Carolina - Department of Environement and Natural resources - Division of Water Quality - Groundwater Section 1936 Mail Service Center - Raleigh, N.C. 27699-1636- Phone (919) 7333221 WELL CONSTRUCTION RECORD AMW-8 WELL CONTRACTOR: ARM's Waterworks - Don Cummings WELL CONTRACTOR CERTIFICATION #: 2412 STATE WELL CONSTRUCTION PERMIT #: 1. WELL USE (Check Applicable Box): Municipal Industrial Agricultural 0 Monitoring El Recovery D Heat Pump Water injection Other If Other, List use: 2. WELL LOCATION: (Show sketch of the location below Nearest Town: Atkinson County: Pender 700 East Church Street (Road Name and Numbers, Community, or Subdivision and Lot No.) 3. OWNER Woodcock Oil Company Address 700 East Church Street (Street or Route No.) Atkinson. NC 28421 City or Town State Zip Code 4. DATE DRILLED 10/18/99 5. TOTAL DEPTH 17.5' 6. CUTTINGS COLLECTED YES NO X 7. DOES WELL REPLACE EXISTING WELL? YES _ NO x 8. STATIC WATER LEVEL Below Top of Casing: 10 Ft. 9. TOP OF CASING IS 0 Ft. Above Land Surface* 'Top of casing terminated at/or below land surface requires a variance In accor- dance with 16A NCAC 2C.0118 10. YIELD (gpm): N/A METHOD OF TEST N/A DRILLING LOG DEPTH From To SEE ATTACHED Formation Description 11. WATER ZONES (depth): Surficial Aquifer If additional space is needed use back of form 12. CHLORINATION: Type N/A Amount N/A 13. CASING Wall Thickness. LOCATION SKETCH Depth Diameter Or Weight/Ft. Material (Show direction and distance from at least two State Roads, or other map reference points) From 0 To 7.5 Ft. 2" SCH40 PVC From To Ft. From To Ft. 14. GROUT SEE ATTACHED Depth Material Method From 3.5 To 5.5 Ft. Bentonite Poured From To Ft. From To Ft. 15. SCREEN Depth Diameter Slot Size Material From 7.5 To 17.5 Ft. 2" .010 PVC From To Ft. From To Ft. 16. SAND/GRAVEL PACK: Depth Size Material From 5.5 To 17.5 Ft. Torpedo Sand From To Ft. From To Ft. 17. REMARKS: I DO HEREBY CERTIFY THAT THIS WELL WAS CONSTRUCTED IN ACCORDANCE WITH 15A NCAC 2C, WELL CONSTRUCTION STANDARDS, AND THAT A COPY THIS RECORD HAS BEEN PROVIDED TO THE WELL OWNER. FOR OFFICE USE ONLY Quad No: SIGNATURE OF PERSON Submit original to Division of Water qu S/aa%p 0 UCTING THE WELL D TE Groundwater Section within 30 days 1 North Carolina - Department of Environement and Natural resources - Division of Water Quality - Groundwater Section 1936 Mail Service Center - Raleigh, N.C. 27699-1636- Phone (919) 733-3221 WELL CONSTRUCTION RECORD AMW-9 WELL CONTRACTOR: ARM's Waterworks - Don Cummings WELL CONTRACTOR CERTIFICATION #: 2412 STATE WELL CONSTRUCTION PERMIT #: 1. WELL USE (Check Applicable Box): Municipal Industrial Agricultural Monitoring ❑x Recovery Heat Pump Water injection Other If Other, List use: 2. WELL LOCATION: (Show sketch of the location below Nearest Town: Atkinson County: Pender 700 East Church Street DRILLING LOG DEPTH Formation Description (Road Name and Numbers, Community, or Subdivision and Lot No.) 3. OWNER Woodcock Oil Company Address 700 East Church Street (Street or Route No.) Atkinson, NC 28421 City or Town State Zip Code 4. DATE DRILLED 10/19/99 5. TOTAL DEPTH 19.5' 6. CUTTINGS COLLECTED YES _ NO X 7. DOES WELL REPLACE EXISTING WELL? YES _ NO x 8. STATIC WATER LEVEL Below Top of Casing: 10.5 Ft. 9. TOP OF CASING IS 0 Ft. Above Land Surface* "Top of casing terminated at/or below land surface requires a variance In accor- dance with 15A NCAC 2C.0118 10. YIELD (gpm): N/A METHOD OF TEST N/A From To SEE ATTACHED 11. WATER ZONES (depth): Surficial Aquifer If additional space is needed use back of form 12. CHLORINATION: Type N/A Amount N/A 13. CASING Wall Thickness LOCATION SKETCH Depth Diameter Or Weight/Ft. Material (Show direction and distance from at least two State Roads, or other map reference points) From 0 To 9.5 Ft. 2" SCH40 PVC From To Ft. From To Ft. 14. GROUT Depth Material Method From 3.5 To 7.5 Ft. Bentonite Poured From To Ft. From To Ft. 15. SCREEN Depth Diameter Slot Size Material From 9.5 To 19.5 Ft. 2" .010 PVC From To Ft. From To Ft. 16. SAND/GRAVEL PACK: Depth Size Material From 7.5 To 19.5 Ft. Torpedo Sand From To Ft. From To Ft. SEE ATTACHED 17. REMARKS: I DO HEREBY CERTIFY THAT THIS WELL WAS CONSTRUCTED IN ACCORDANCE WITH 15A NCAC 2C, WELL CONSTRUCTION STANDARDS, AND THAT A COPY OF THIS RECORD HAS BEEN PROVIDED TO THE WELL OWNER. 5faa bt) FOR OFFICE USE ONLY Quad No: SIGNATURE OF PE SON CO '•f : ACTING THE WELL DAT roundwater Section within 30 days Submit original to Division of Water qua!' Notice of Intent to Construct or Operate Injection Wells Woodcock Oil Company, Atkinson, North Carolina APPENDIX C ACCESS AGREEMENT FROM SITE PROPERTY OWNER ATC En1RON•ENIAL • OEORCMICAI NII0.61s6iCIENLCi• k11EN14iiE511116 UNDERGROUND STORAGE TANK SECTION February 10, 2020 Mr. Hassan Osman Hydrogeologist DWM/UST Section 1637 Mail Service Center Raleigh, NC 27699-1637 Dear Mr. Osman RE: Woodcock Oil Company 700 East Church Street Atkinson, Pender County, North Carolina Incident Number: 16996 I am/We are the owner(s) of a parcel of property, located at or near the incident in question, and hereby permit the Department of Environmental Quality (Department) or its contractor to enter upon said property for the purpose of conducting an assessment and/or remediation of the groundwater and/or soils under the authority of G.S. 143-215.94G. I am/We are granting permission to the lands we own or control with the understanding that: 1. The investigation shall be conducted by the UST Section of the Department's Division of Waste Management or its contractor. 2. The costs of construction and maintenance of the site and access shall be borne by the Department or its contractor. The Department or its contractor shall protect and prevent damage to the surrounding lands. Any damages will be restored by the Department or its contractor to as close to the pre -work condition as practicably possible. 3. Unless otherwise agreed, the Department or its contractor shall have access to the site by the shortest feasible route to the nearest public road. The Department or its contractor will notify the land owners 48 hours prior to entry and may enter upon the land at reasonable times and have full right of access during the period of the investigation. 4. Any claims which may arise against the Department or its contractor shall be governed by Article 31 of Chapter 143 of the North Carolina General Statutes, Tort Claims Against State Departments and Agencies, and as otherwise provided by law. 5. The information derived from the investigation shall be made available to the owner upon request and is a public record, in accordance with G.S. 132-1. 6. The activities to be carried out by the Department or its contractor are for the primary benefit of the Department and of the State of North Carolina. Any benefits accruing to the owner are incidental. The Department or its contractor is not and shall not be construed to be an agent, employee, or contractor of the landowner. No representations or warranties, either expressed or implied, have been made to me/by the Department, the State of North Carolina, or its/their contractor(s) regarding the results that may be obtained or the quality of work to be performed. I/We agree not to interfere with, remove or any ways damage the Department's well(s) or its contractor's well(s) and equipment during the investigation. Sincerely, Signature Type/Print Name of Owner or Agent gri 92-0563 Phone Number % 2C2 aura_ 52. Address tic q 2- City/State/Zip Code Date RE: Woodcock Oil Company 700 East Church Street Atkinson, Pender County, North Carolina Incident Number: 16996