SW6210101_1729 Volumes Required_20210330
GCSS Required Storm Volume Infiltration Basin #1 Drainage Area: 3.20 acres 139,568 sf Impervious Area: 114,042 sf (2.61ac) % Impervious: 81.7% 1 inch Storm Event: Rv = 0.05+0.009 I Rv = runoff coefficient I= percent impervious Rv=0.05+0.009*81.7% = 0.7853 For volume that must be controlled: Volume=3,630*Rd*Rv*A Volume required = 3,630*(1 inch)*(0.7853)*3.20acres = 9,122cf Volume provided = 12,683 cf