Loading...
HomeMy WebLinkAboutSW5210301_SSW-SWU-101-Application-DEMLR-SPU Oct 2013_20210326DEMLR USE ONLY Date Received Fee Paid Permit Number Applicable Rules: 11 Coastal SW - 1995 11 Coastal SW - 2008 11 Ph 11 - Post Construction (select all that apply) El Non -Coastal SW- HQW/ORW Waters OUniversal Stormwater Management Plan El Other WQ Mgmt Plan: State of North Carolina Department of Environment and Natural Resources Division of Energy, Mineral and Land Resources STORMWATER MANAGEMENT PERMIT APPLICATION FORM This form may be photocopiedfor use as an original 1. GENERAL INFORMATION 1. Project Name (subdivision, facility, or establishment name - should be consistent with project name on plans, specifications, letters, operation and maintenance agreements, etc.): North Carolina Central Universi1y School of Business 2. Location of Project (street address): 1206 S Alston Avenue City:Durham County:Durham Zip:27707 3. Directions to project (from nearest major intersection): The site sits between the intersection of Dupree and S. Alston Avenue and the intersection of Lawson and S. Alston Avenue 4. Latitude:35'5834" N Longitude: 78' 53' 40" W of the main entrance to the project. 11. PERMIT INFORMATION: 1. a. Specify whether project is (check one): ZNew F-IModification El Renewal w/ Modificationt tRenewals with modifications also requires SVM-102 - Renewal Application Form b. If this application is being submitted as the result of a modification to an existing permit, list the existing permit number , its issue date (if known) , and the status of construction: E]Not Started E]Pairtially Completed* E] Completed* *provide a designer's certification 2. Specify the type of project (check one): F-]Low Density ZHigh Density F_]Drains to an Offsite Stormwater System E]Other 3. If this application is being submitted as the result of a previously returned application or a letter from DEMLR requesting a state stormwater management permit application, list the stormwater project number, if assigned, and the previous name of the project, if different than currently proposed, 4. a. Additional Project Requirements (check applicable blanks; information on required state permits can be obtained by contacting the Customer Service Center at 1-877-623-6748): F-ICAMA Major ZSedimentation/ Erosion Control: 4.55 ac of Disturbed Area F_1NPDES Industrial Stormwater 0404/401 Permit: Proposed Impacts _ b. If any of these permits have already been acquired please provide the Project Name, Project/ Permit Number, issue date and the type of each permit: 5. Is the project located within 5 miles of a public airport? ZNo F-]Yes If yes, see S.L. 2012-200, Part W: ht!p:aortal.ncdenr.org/web/Ir/rules-and-regulations FonnSWU-101 Version Oct. 31,2013 Page I of 6 III. CONTACT INFORMATION 1. a. Print Applicant / Signing Official's name and title (specifically the developer, property owner, lessee, designated government official, individual, etc. who owns the pLojec ): Applicant/ Organization: North Carolina Central Universi1y Signing Official & Title:Akua 1. Matherson, CFO & Vice Chancellor for Administration & Finance b. Contact information for person listed in item la above: Street Address: 1801 Fayetteville Street City: Durham State: NC Zip: 27707 Mailing Address (if applicable): Same as above city: State: Zip: Phone: (919 530-6204 Fax: (919 530-7948 Email: amathers@ncc-u.edu Please check the appropriate box. The applicant listed above is: E The property owner (Skip to Contact Information, item 3a) F-1 Lessee* (Attach a copy of the lease agreement and complete Contact Information, item 2a and 2b below) F-1 Purchaser* (Attach a copy of the pending sales agreement and complete Contact Information, item 2a and 2b below) F-1 Developer* (Complete Contact Information, item 2a and 2b below.) 2. a. Print Property Owner's name and title below, if you are the lessee, purchaser or developer. (This is the person who owns the property that the project is located on): Property Owner/ Organization: Signing Official & Title: b. Contact information for person listed in item 2a above: Street Address: city: State: Zip: Mailing Address (if applicable): city: State: Zip: Phone: Fax: Email: 3. a. (Optional) Print the name and title of another contact such as the project's construction supervisor or other person who can answer questions about the project: Other Contact Person/ Organization: North Carolina Central Universi1y Signing Official & Title: Diedra McEn1yre, b. Contact information for person listed in item 3a above: Mailing Address: 1801 Fayetteville Street City: Durham State: NC Zip: 27707 Phone: ( 919 530-7947 Fax: (919 530-7948 Email: dmceniyre@nccu.edu 4. Local jurisdiction for building permits: Cit�� of Durham Point of Contact: Phone #: Fonu SWU-101 Version Oct. 3 1, 2013 Page 2 of 6 IV. PROJECT INFORMATION 1. In the space provided below, briefly summarize how the stormwater runoff will be treated. Wet Detention Pond 2. a. If claiming vested rights, identify the supporting documents provided and the date they were approved: F-1 Approval of a Site Specific Development Plan or PUD Approval Date: F-1 Valid Building Permit Issued Date: F-1 Other: Date: b. If claiming vested rights, identify the regulation(s) the project has been designed in accordance with: F-1 Coastal SW - 1995 F-1 Ph 11 - Post Construction 3. Stormwater runoff from this project drains to the Third Fork Creek -Jordan La River basin. 4. Total Property Area: 2.50 —acres 5. Total Coastal Wetlands Area: 0 acres 6. Total Surface Water Area: 0 acres 7. Total Property Area (4) - Total Coastal Wetlands Area (5) - Total Surface Water Area (6) = Total Project Area': 2.5 acres + Total project area shall be calculated to exclude thefollowing: the normal pool of impounded structures, the area between the banks of streams and rivers, the area below the Normal H' h Water (NHM line or Mean High Water (A4HYQ line, and coastal wetlands landwardfrom the NHW (or Mx line. The resultant project area is used to calculate overall percent built upon area (BLLA). Non -coastal wetlands landward of the NHW(or A4HM line may be included in the total project area. 8. Project percent of impervious area: (Total Impervious Area / Total Project Area) X 100 = 44.84 % 9. How many drainage areas does the project have? 1 (For high density, count I for each proposed engineered stormwater BMP. For low density and other projects, use I for the whole property area) 10. Complete the following information for each drainage area identified in Project Information item 9. If there are more than four drainage areas in the project, attach an additional sheet with the information for each area provided in the same format as below. Basin Information Drainage Area . Drainage Area Drainage Area Drainage Area Receiving Stream Name Third Fork Creek Stream Class QNSW Stream Index Number 16-41-1-12-(l) Total Drainage Area (sf) 108830 On -site Drainage Area (sf) 108830 Off -site Drainage Area (sf) 0 Proposed Impervious Area** (sf) 47284 % impervious Area** (total) 44.84 Impervious- Surface Area Drainage Area Drainage Area Drainage Area Drainage Area On -site Buildings/Lots (sf) 28540 On -site Streets (sf) 0 On -site Parking (sf) 12297 On -site Sidewalks (sf) 6447 Other on -site (sf) 0 Future (sf) 0 Off -site (sf) 0 Existing BUA*** (sf) 0 Total (sf): 1 47284 1 1 1 Stream Class and Index Number can be determined at: http.aortal.ncdenr.orglweblwq&slcsulclassifications Imyervi . ous area is defined as the built upon area including, but not limited to, buildings, roads, parking areas, ewalks, gravel areas, etc. Fonn SWU-101 Version Oct. 3 1, 2013 Page 3 of 6 'Report only that amount of existing BLLA that will remain after development. Do not report any existing BLLA that is to be removed and which will be replaced by new BUA. 11. How was the off -site impervious area listed above determined? Provide documentation. NZA Pro aects in Union County: Contact DEMR Central Office staff to check if theproject is located within a Threatened & Endangered Species watershed that may be subject to more stringent stormwater requirements as per 15A NCAC 02B .0600. V. SUPPLEMENT AND O&M FORMS The applicable state stormwater management permit supplement and operation and maintenance (O&M) forms must be submitted for each BMP specified for this project. The latest versions of the forms can be downloaded fromhttr)://nortal.ncdenr.orLy/web/wa/ws/su/bmn-manual. VI. SUBMITTAL REQUIREMENTS Only complete application packages will be accepted and reviewed by the Division of Energy, Mineral and Land Resources (DEMLR). A complete package includes all of the items listed below. A detailed application instruction sheet and BMP checklists are available from http://12ortal.ncdenr.org/web/wq/ws/su/statesw/forms—docs. The complete application package should be submitted to the appropriate DEMLR Office. (The appropriate office may be found by locating project on the interactive online map at htII2://12ortal.ncdenr.org/web/wq/ws/su/mal2s.) Please indicate that the following required information have been provided by initialing in the space provided for each item. All original documents MUST be signed and initialed in blue ink. Download the latest versions for each submitted application package fromht�2://12ortal.ncdenr.org/web/wq/ws/su/statesw/forms docs. Initials 1. Original and one copy of the Stormwater Management Permit Application Form. RLB 2. Original and one copy of the signed and notarized Deed Restrictions & Protective Covenants N/A Form. (if required as per Part VII below) 3. Original of the applicable Supplement Form(s) (sealed, sig!2ed and dated) and O&M RLB agreement(s) for each BMP. 4. Permit application processing fee of $505 payable to NCDENR. (For an Express review, refer to RLB http://www.envhelp.org/pages/onestopexpress.html for information on the Express program and the associated fees. Contact the appropriate regional office Express Permit Coordinator for additional information and to schedule the required application meeting.) 5. A detailed narrative (one to two pages) describing the stormwater treatment/ management for RLB 6. A USGS map identifying the site location. If the receiving stream is reported as class SA or the RLB receiving stream drains to class SA waters within 1/2 mile of the site boundary, include the 1/2 mile radius on the map. 7. Sealed, signed and dated calculations (one copy). RLB 8. Two sets of plans folded to 8.5" x 14" (sealed, signed, & dated), including: RLB a. Development/ Project name. b. Engineer and firm. c. Location map with named streets and NCSR numbers. d. Legend. e. North arrow. f. Scale. g. Revision number and dates. h. Identify all surface waters on the plans by delineating the normal pool elevation of impounded structures, the banks of streams and rivers, the MI-IW or NHW line of tidal waters, and any coastal wetlands landward of the MHW or NFIW lines. Delineate the vegetated buffer landward from the normal pool elevation of impounded structures, the banks of streams or rivers, and the MI-IW (or NHW) of tidal waters. i. Dimensioned property/ project boundary with bearings & distances. j. Site Layout with all BUA identified and dimensioned. k. Existing contours, proposed contours, spot elevations, finished floor elevations. 1. Details of roads, drainage features, collection systems, and stormwater control measures. m. Wetlands delineated, or a note on the plans that none exist. (Must be delineated by a qualified person. Provide documentation of qualifications and identify the person who made the determination on the plans. n. Existing drainage (including off -site), drainage easements, pipe sizes, runoff calculations. o. Drainage areas delineated (included in the main set of plans, not as a separate document). Fonn SWU-101 Version Oct. 3 1, 2013 Page 4 of 6 p. Vegetated buffers (where required). 9. Copy of any applicable soils report with the associated SHWT elevations (Please identify RLB elevations in addition to depths) as well as a map of the boring locations with the existing elevations and boring logs. Include an 8.5"x11" copy of the NRCS County Soils map with the project area clearly delineated. For projects with infiltration BMPs, the report should also include the soil type, expected infiltration rate, and the method of determining the infiltration rate. (Infiltration Devices submitted to WiRO: Schedule a site visitfor DEMLR to verify the SHVVT prior to submittal, (910) 796-7378.) SEE ATTACHED COPIES OF DEEDS 10. A copy of the most current property deed. Deed book: Page No: RLB 11. For corporations and limited liability corporations (LLC): Provide documentation from the NC N/A Secretary of State or other official documentation, which supports the titles and positions held by the persons listed in Contact Information, item la, 2a, and/or 3a per 15A NCAC 21-1.1003(e). The corporation or LLC must be listed as an active corporation in good standing with the NC Secretary of State, otherwise the application will be returned. http: / / www.secretaiy.state.nc.us/ Corporations/ CSearch.aspx AF VII. DEED RESTRICTIONS AND PROTECTIVE COVENANTS For all subdivisions, outparcels, and future development, the appropriate property restrictions and protective covenants are required to be recorded prior to the sale of any lot. If lot sizes vary significantly or the proposed BUA allocations vary, a table listing each lot number, lot size, and the allowable built -upon area must be provided as an attachment to the completed and notarized deed restriction form. The appropriate deed restrictions and protective covenants forms can be downloaded from htW://12ortal.ncdenr.org/web/Ir/state- stormwater-forms docs. Download the latest versions for each submittal. In the instances where the applicant is different than the property owner, it is the responsibility of the property owner to sign the deed restrictions and protective covenants form while the applicant is responsible for ensuring that the deed restrictions are recorded. By the notarized signature(s) below, the permit holder(s) certify that the recorded property restrictions and protective covenants for this project, if required, shall include all the items required in the permit and listed on the forms available on the website, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the required covenants cannot be changed or deleted without concurrence from the NC DEMLR, and that they will be recorded prior to the sale of any lot. VIII. CONSULTANT INFORMATION AND AUTHORIZATION Applicant: Complete this section if you wish to designate authority to another individual and/or firm (such as a consulting engineer and/or firm) so that they may provide information on your behalf for this project (such as addressing requests for additional information). Consulting Engineer:Richard Butt Consulting Firm: John Davenport Engineering, Inc. Mailing Address:119 Brookstown Avenue, Suite PH1 City: Winston-Salem Phone: (336 ) 744-1636 Email: rbutL@davenportworld.com State: NC Fax: ( Zip: 27101 IX. PROPERTY OWNER AUTHORIZATION (if Contact Information, item 2 has been filled out, complete this section) 1, (print or type name ofperson listed in Contact Information, item 2a) , certify that I own the property identified in this permit application, and thus give permission to (print or type name ofperson listed in Contact Information, item 1a) with (print or type name of organization listed in Contact Information, item 1a) to develop the project as currently proposed. A copy of the lease agreement or pending property sales contract has been provided with the submittal, which indicates the party responsible for the operation and maintenance of the stormwater system. Form SWU-101 Version Oct. 3 1, 2013 Page 5 of 6 As the legal property owner I acknowledge, understand, and agree by my signature below, that if my designated agent (entity listed in Contact Information, item 1) dissolves their company and/or cancels or defaults on their lease agreement, or pending sale, responsibility for compliance with the DEMLR Stormwater permit reverts back to me, the property owner. As the property owner, it is my responsibility to notify DEMLR immediately and submit a completed Name/Ownership Change Form within 30 days; otherwise I will be operating a stormwater treatment facility without a valid permit. I understand that the operation of a stormwater treatment facility without a valid permit is a violation of NC General Statue 143-215.1 and may result in appropriate enforcement action including the assessment of civil penalties of up to $25,000 per day, pursuant to NCGS 143-215.6. Signature: 1, a Notary Public for the State of , do hereby certify that before me this day of Date: County of personally appeared . and acknowledge the due execution of the application for a stormwater permit. Witness my hand and official seal, SEAL My commission expires. X. APPLICANT'S CERTIFICATION 1, (print or type name ofperson listed in Contact Information, item 1a) Akua f. Matherson certify that the information included on this permit application form is, to the best of my knowledge, correct and that the project will be constructed in conformance with the approved plans, that the required deed restrictions and protective covenants will be recorded, and that the proposed project complies with the requirements of the applicable stormwater rules under 15A NCAC 21-1.1000 and any other applicable state stormwater requirements. Signature: — Date: 1, , a Notary Public for the State of County of do hereby certify that before me this day of personally appeared . and acknowledge the due execution of the application for a stormwater permit. Witness my hand and official seal, SEAL My commission expires. Fonn SWU-101 Version Oct. 3 1, 2013 Page 6 of 6