Loading...
HomeMy WebLinkAboutWI0300184_Regional Office Historical File Pre 2018Central Files APS SWP 10/18/11 Permit Number WI0300184 Permit Tracking Slip Program Category Ground Water Status Project Type Active New Project Permit Type Version Permit Classification Injection Water Only GSHP Well System (5QW) 1.00 Individual Primary Reviewer Permit Contact Affiliation eric,g,smith Coastal SW Rule Per Flow siiity Facility Name Jacob Deal SFR Location Address 1113 Gregory Ln Statesville NC 28677 Owner Randall Cutter 6105 Rest Home Rd Claremont NC 28610 Major/Minor Region Minor Mooresville Owner Name Owner Type Individual Jacob Deal Owner Affiliation County lredell Affiliation Jacob Deal 1113 Gregory Ln Statesville NC 28677 Dates/Events Orig Issue 10/18/11 App Received 10/07/11 Regulated Activities Heat, Pump injection Outfai l Draft Initiated Scheduled Issuance Public Notice Issue Effective Expiration 10/18/11 10/18/11 Waterbody Narne Stream Index Number Current Class Subbasin C E North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Govemor Director Secretary 10/19/2011 Jacob P. Dean 1113 Gregory Lane Statesville, NC 28677 Subject: Acknowledgement of Intent to Construct Type 5QW Injection Well System Permit No. W10300184 1113 Gregory Lane, Statesville, NC 28677 Dear Mr. Dean: On October 7, 2011, the Aquifer Protection Section (APS) received notification of your intent to construct a closed -loop water -only geothermal injection well system for the operation of a ground -source heat pump located at the address referenced above. An individual permit is not required for the construction and operation of this type of geothermal injection well system as long as the following conditions are met: 1. The injection well system contains only potable water, 2. The injection well system is constructed in accordance with well construction standards specified in North Carolina Administrative Code Title 15A Section 2C Subchapter .0213, and 3. The required notification form and associated maps have been completely and accurately submitted. Failure to comply with all of these conditions constitutes a violation of the North Carolina Well Construction Act and North Carolina Administrative Code Title 15A Section 2C Subchapter .0211(11)(2). Additionally, you should contact the Iredell County Health Department as they may have additional requirements for this type of system. Noncompliance with applicable state, county, or municipal rules and regulations may result in the assessment of civil penalties. Please contact Mike Rogers at (919) 715-6166 or Michael.Rouers@ncdenr.ov if you have any questions. Sincerely, OLct.6,00ruL- for Debra Watts Supervisor cc: Mooresville Regional Office - APS APS Central Files - Permit No. WI03001 84 Iredell County Health Dept. Go! Green Drilling, Inc (Randall Cutter) JP Plumbing Sc Heating AQUIFER PROTECTION SECTION 1636 Mail Service Center, Raleigh, North Carolina 27699-1636 Location: 2728 Capital Boulevard, Raleigh, North Carolina 27604 Phone: 919-733-3221 \ FAX 1: 919-715-0588; FAX 2: 919-715-6048 \ Customer Service:1-877-623-67,48 Internet wwuv.newraterouality.orq An Equal Opportunity 1 Ainrmative Action Employer NorthhCaroii._�la fat 1' r 1 C. WELI! DRILLER INFORMATION Company Name: Go! Green Drilling, Inc. Well Driller Contractor's Name: NC Contractor Certification No.: 2818-A Randall E. Cutter Contact' Person: Randall Cutter Address: 6105 Rest Home Rd. EMAIL Address: randvaaoareendrillina.com 1 City: Claremont Zip Code: 28610 County: Catawba Office •Fele No.: 828-367-1293 Cell No.: 828-228-1695 D. HEAT TUMP CONTRACTOR INFORMATION'(if different than driller) Company Name: 7P Piumbin2 & Heating Contact' Person: EMAIL Address: Address: 235 North Center Street City: Statesville Zip Code: 28677 County: Iredell Office Tele No.: (704) 872-5486 Cell No.: ! E. STATUS OF APPLICANT Private X Federal: Commercial: l State: .1 Municipal: Native American Lands: 1 F. INJECTION PROCEDURE (briefly describe how the injection well(s) will be used) Water ONLY closed loop geothermal vertical loops G. WELLICONSTRUCTION DATA (1) Proposed date to be constructed: 10/] 0/2011 Number of borings: 4 Approximate depth of each boring (feet): 170' (2) Type of tubing to be used (copper, PVC, etc): High Density Polvethelene (3) Well casing. Is the well(s) cased? (check either (a.) Yes or (b.) No below) (a) 1 Yes if yes, then provide casing information below Typ galvanized steel _black steel plastic _other (specify) Casing depth: From to feet (reference to land surface) Casi l g ca.-tends to above ground inches (b) No X (4) Grant Info (material surrounding well casing and/or piping): • I (a) Grout type: Neat Cement Bentonite X Other (specify) Thermal -Enhanced (b) Grout placement: Pumping X Pressure Other (c) Grout depth of tubing (reference to land surface): from 0 to 170 (feet) If well has casing, indicate grout depth: from to (feet) GPU/UIC 5QW Notification of intent Form (Revised 8/2008) i • Page 2 NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES (NCDENR. NOTIFICATION OF INTENT TO CONSTRUCT A CLOSED -LOOP GEOTHERMAL WATER -ONLY INJECTION WELL SYSTEM: TYPE 5-QW WELL(S) In Accordance with the provisions of NCAC Title 15A: 02C.0200, please complete this notification and mail to address on the hack page (please .Print or TNpe information). DATE: October 6 20 1 1 ki-1-071:01%14 Well Type Confirmation: Does the proposed system circulate potable r only (no additives) in continuous piping that completely isolates the fluid from the environment (i.e. closecirloop)? Yes X Continue completing this form, No Do Not complete this form. Complete other UIC application forms for installing either a 3A7 wefl (open -loop well injecting potable water into the aquifer) or a 5QM well (closed -loop well containing additives such as R-22,. ethanol, or other antifreen or corrosion inhibitors). A. PROPERTY OWNERS)/APPLICANT(S) List melt Property Owner listed on property deed (if owned by a business or govermnelfl agency,to entity and a representative wlauthority for signature): , J (1) Mailing Address : 1113 La. c City: Statesville State: NC Zip Code: 28677 Home/Office Tele No.: County: ire Cell No.: c70,1) 902-3979 Email Address: jacobiriPsph,coin Website: wpsnhcortt (2) Physical Address of Well. Site (if different than above: Same City: State: Zip Code: , Cou Home/Office Tele No,: Cell No.: E. AUTHORIZED AGENT OF OWNER,. IF ANY (if the Permit Applicant does not own the subject propeny. attach a letter from the property owner authorizing Agent to install and operate UIC well) .Company Name: Contact Person: Address: City: State: EMAIIL Adcires:s; Zip Code: Office-Tele No.: Website Address of Company, ifany: (PUILIC 5cAV Nolincanzm of intr.rv., i'orm (Rtwisecl 8120)g) Linty: Cell No.: RE4444,', DV-43 A474,,r4;4:44‘ ,74',444 -44 "4'7'44, SF TON 142,,ez. 2011. Il. INJECTION=RELATED EQUIPMENT Attach a diagram showing the engineering layout or proposed modification of the injection equipment and exterior piping/tubing associated with the injection operation. The manufacturer's brochure may provide supplementary information. I. LOCATION 'OF WELL(S) Attach two copies of maps showing the following information: (1) Include a Site Map (can be drawn) showing: buildings, property lines, surface water bodies, potential sources of groundwater contamination and the orientation of and distances between the proposed well(s) and any existing well(s) or waste disposal facilities such as septic tanks or drain fields located within 200 feet of the geothermal heat pump well system. Label al! features clearly and include a north arrow. €I'he Site Map must show the subject property in relation to the surrounding area by using at least two fixed reference points such as roads, streams, and/or highway intersections. J. CERTIFICATION 4 (2) Noe: This`Permif',�pplieitiiiii*ustbe`srgnediiy;eieliperon'-agpcariilg.on;ttie �` 're tit a iileg pr:operioiea I "I here,y certify, under penalty of law, that I have personally examined and am familiar with the information submitted in this document and all attachments thereto and that, based on my inquiry of those individuals immediately responsible for obtaining said information, I believe that the information is true, accurate and complete. I am aware that there are significant penalties, including the possibility of fines and imprisonment, for submitting false information. I agree to construct, operate, maintain, repair, and if applicable, abandon the injection well and all related appurtenances in accordance with approved specifica ' d conditions of the Permit." 'inure orProperty Owne7Applicant ' -� , . i � e oi Print or Type Full Name and title Signature of Property Owner/Applicant Print or Type Full Name and title Signature of Authorized Agent, if any Print or Type Full Name and title Please return two copies of the completed Application package to: North Carolina DENR-DWQ Aquifer Protection Section-UIC Program 1636 Mail Service Center Raleigh, NC 27699-1636 RECEIVED/ OENR / NV..? (919) 715-6935 UiF p'ppll ��l I i S7C i IDS! GPU/UIC 5QW Notifiaiion of Intent Form (Revised 8/2008) OCT 0 E 2011 Page 3 Jacob Deal 1113 Gregory Ln. Statesville, NC 28677 Boreholes will be 20' apart. No existing water wells or septic system on this site. City sewer and water. RECEIVED I IMO. Rogers, Michael From: Randall Cutter [randy@gogreendrilling.com] Sent: Friday, October 07, 2011 9:10 AM To: Rogers, Michael Subject: 5-QW application for deal residence Attachments: Deal - 5QW Geothermal Well Application - Water.pdf; Deal - Borehole Layout.pdf Mike, I have been trying to fax the attached 5-QW to Tonya but she said their fax is not working and to email it to you. Please see attached. Thanks, Randall E. Cutter, CGWP IGSHPA Accredited Go! Green Drilling, Inc. 6105 Rest Home Rd. Claremont, NC 28610 828-367-1293 (office) 828-228-1695 (cell) randv@gogreendrilling.com www.GoGreenDrilling.com 1 Rogers, Michael From: Randall Cutter (randy@gogreendriliing.com] Sent: Friday, October 07, 2011 1:15 PM To: Rogers, Michael Subject: RE: 5-QW application for deal residence Michael, Boreholes GL-3 & GL-4 are 16.5' from the utility building. GL-1 is 30+' from the house. If you need anything else, please let me know. Thanks, Randall E. Cutter, CGWP IGSHPA Accredited Go! Green Drilling, inc. 6105 Rest Home Rd. Claremont, NC 28610 828-367-1293 (office) 828-228-1695 (cell) randy@gogreendrilling.com www.GoGreenDrilling.com From: Rogers, Michael fmailto:michael.rogers5ncdenr.aovl Sent: Friday, October 07, 2011 11:56 AM To: Randall Cutter Subject: RE: 5-QW application for deal residence How far are the borings from any structures? We prefer at least a minimum of 15 feet. Michael Rogers, P.G. (NC & FL) Environmental Specialist NC Div of Water Quality- Aquifer Protection Section (APS) 1636 Mail Service Center Raleigh, NC 27699-1636 Direct Line (919) 715-6166; Fax 715-6048 (put to my attn on cover letter) http://r ortal.ncdenr.org/web/wa/apsfgworo/permit-apolications#geothermApps E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties From: Randall Cutter fmailto:randvegonreendrilling.com7 Sent: Friday, October 07, 2011 9:10 AM To: Rogers, Michael Subject: 5-QW application for deal residence Mike, I have been trying to fax the attached 5-QW to Tonya but she said their fax is not working and to email it to you. Please see attached. Thanks, 1 Randall E.Cutter, [GVVP |G5HPAAccredited Go! Green Drilling, Inc. 610SRest Home Rd. Claremont, NC28GlD 828'367-1293/ofhce\ 828-228'1695(ceH) namd°@gngnaen�7iUi1ng,com vvww.GmGreenDhUimg.con3 2