Loading...
HomeMy WebLinkAbout20090554 Ver 3_Olde Mill Stream II Constr Plat for Signature_20210325MAJOR SUBDIVISION CONSTRUCTION PLAT PHASE TWO OLDE MILL STREAM Rocky Mount Township Nash County, North Carolina DEVELOPER: HODGE MORRIS, LLC 2101 F. MILLER ROAD WILSON, NC 27893 PREPARED BY: BARTLETT ENGINEERING & SURVEYING, PC 1906 NASH STREET NORTH WILSON, NORTH CAROLINA 27893-1726 SP1 CP1 CP2 CP3 CP4 CP5 CP6 CP7 CP8 CP9 CP10 SCM1 SCM2 SCM3 SHEET INDEX OVERALL SITE PLAN SHADYBROOK DRIVE OUTFALL TO POND 1 SHADYBROOK DRIVE OUTFALL 1 TO POND 2 SANITARY SEWER OUTFALL SHADY CREST ROAD SHADY CREST ROAD SAND PEBBLE PLACE BUBBLING BROOK LANE SHADYBROOK COURT OUTFALL 2 TO POND 2 OVERALL UTILITY PLAN STORMWATER STRUCTURE & PIPE TABLE DETAILS DETAILS POND 1 DETAILS POND 2 DETAILS DRAINAGE AREA TO SCM APPENDIX A EROSION CONTROL PLAN : � .r)._ . .et i • °%.RT S. B N�;�`� %%%%%%11111111 SITE DATA: TOTAL ACREAGE PHASE 1 PHASE 2 TOTAL NUMBER OF LOTS PHASE 1 PHASE 2 ROADWAY IMPERVIOUS PHASE 1 PHASE 2 TOTAL TOTAL BUA LOT 1-61 IOT 62-203 TOTAL OPEN SPACE (LOT 206-207) PROPOSED IMPERVIOUS PHASE 1 PHASE 2 TOTAL PIN NUMBERS = 95.3 AC.± = 20.31 AC.± = 38.42 AC.± = 61 (INCLUDING SCM LOT 48) = 142 = 2.42± AC. (105,337± SF) = 4.05± AC. (176.397± SF) = 6.47± AC. (281,734± SF) = 3.25 AC. (141,600± SF) f = 12.82 AC. (5581540± SF) = 31.2± ACRES (INCLUDING SCM'S) = 5.67 AC. (246,937± SF) (5.95%) = 13.62 AC. (593,337± SF) (14.29%) = 19.23 AC. (840,274± SF) (20.24%) = 383018310386 = 383018311671 umissJ7 _ JB SHADY CREST ROAD 40 srosiist 172171 . :: :: :: ® SHADYBROOK COURT ( 45 13S V $4 139 aspp 72B PHASE 2 4 144"�o.� 127 128 ' y 209 OPEN SPACE ®�I� _' ...►d1& VICINITY MAP NO SCALE NOTES: PRIOR TO RECORDING THE FINAL PLAT, THE FOLLOWING ITEMS WILL NEED TO BE SUBMITTED TO THE CITY OF ROCKY MOUNT DEPARTMENT OF ENGINEERING: 1. ENGINEER'S CERTIFICATION, RECORD DRAWINGS, AND TAP CARDS FOR THE PUBLIC SEWER LINES. 2. ENGINEER'S CERTIFICATION, RECORD DRAWINGS, AND SIGNED AND NOTARIZED OPERATION AND MAINTENANCE AGREEMENT FOR THE STORMWATER FACILITIES. 3. ENGINEER'S CERTIFICATION, RECORD DRAWINGS, AND FINAL APPROVAL FROM NCDENR PUBLIC WATER SUPPLY FOR THE PUBLIC WATERLINES. 4. COPY OF RECEIPT FROM NCDENR FOR FINAL SEWER CERTIFICATION MUST BE RECEIVED. 5. PDF COPY OF ALL CORRESPONDENCE RELATED TO WATER AND SEWER PERMIT WITH NCDENR, INCLUDING PLAN SETS AND REVISED PLANS MUST BE CC'D TO NEGRETE SILVER ® negrete.siivertrockymountnc.gov (252-972-1127). THIS PLAN IS VALID FOR 2 YEARS FROM DATE OF APPROVAL BY CITY OF ROCKY MOUNT. LOCATION MAP NO SCALE NO ADDITIONS, DELETIONS, CHANGES OR MODIFICATIONS WERE MADE TO THIS PLAN OTHER THAN THOSE REQUESTED BY THE CITY OF ROCKY MOUNT DEVELOPMENT REVIEW COMMITTEE, OTHER THAN LISTED BELOW: REVISIONS: A CRM 2ND REVIEW COMMENTS 10/28/2020 REVISIONS: A CRM 1ST REVIEW COMMENTS 10/13/2020 46 4 JJ ROCKFALL WAY 9 I ID 8 L. t 11 6 12 r 7 48 \ \ 7J 4 14 / 15 2 1 25 r ZONE R-6 ZONE 0-1 29 24 2J • PHASE 1 k\ ,B \ 17 16 • OK SHADYa,O- ( 49 61 \ \/ • 19 60 ' 51 52 56• 1 1 57 , / 56 55 26 27 26 22 19 21 20 207 OPEN SPACE RIVE 5J 54 • ZONE R-6 ' ZONE 0-1 moms 4•44 204 • Certification by the Department of Development Services that this construction plat was approved by the city planning board on _ day of 20 Director of Development Services Certification by the City Engineering Department that this construction plat and required Improvement drawings meet the appropriate city standards. Director of Engineering h I CC ec w4t 1n 1/ 2 I0 d N O Ni N 0 Z 3 0a N 0 0 0 N 0 N U i re a. 3 Li: LOCATION MAP NOT TO SCALE N/F CHARLES & MATTIELEEN JOHNSON DB 947 PG 643 383013037300U ZONE: A-1 (FARM LAND) OUTSIDE CITY LIMITS N/F HAZEL H. POWELL HEIRS DB 1134 PG 240 PB 19 PG 103 373900092172U ZONE: R-30 (RESIDENTIAL) SITE DATA; TOTAL AREA TOTAL NO. OF LOTS TOTAL LIN. FT. OF ST. ZONING BUILDING SETBACKS PROPOSED LAND USE OWNER/DEVELOPER REFERENCE: TAX MAP: • +• + +.I + + +++++ ++ + + + + }} + + ++++ +1+ ++ + +++++ + + \«_ 4 + +�+ •• +=,• + + + + I4 + + + + + + * ++ 1- �«* '_ + ` + + + + + + + OUTSIDE CITY LIMITS ++I++ +++ + + + + ++AfIRftO)i.+*+ 4+++, +'1++++.-LLOCADTION + + ++++ +++*+ .1++ +++++*+*+'+++++++++'++ + + ++ + + +4 +++ +1+ +«+++ + + + - -- �+ +_•. r -,=+ +++++ +++1,-:++++ ++I«+ +A_✓+1+ + + + + + + + ++++ ++++ + ++i + + + + + +++ {+I++++ + + + \ N/F \\....—•' RODNER P. & HOL LOMANZIE P. DB 1561 PG 305 PB 29 PG 335 383017102255 ZONE: R-30 (RESIDENTIAL) 95.3 ACRES± 203 9,092 LF 0-1 & R-6 FRONT SIDE STREET SIDE REAR SINGLE FAMILY 25' 10' 12.5' 20' HODGE—MORRIS, LLC 1708 TRAWICK RD, STE 209 RALEIGH, NC 27604 DEED BOOK 2162 PAGE 770 3830-18-31-0386 RECORD # 21760 3830-18-31-1671 RECORD # 21755 N/F ~— JONATHAN B. WALSTON JENNIFER L. WALSTON DB 2843 PG 991 PB 39 PG 218 373905108577 ZONE: R-30 (RESIDENTIAL) NOTE: AT LEAST ONE (1) LARGE TREE AND ONE (1) SMALL TREE SHALL BE PROVIDED ON ALL SINGLE—FAMILY RESIDENTIAL LOTS. ++0t«++ OPEN. +SPh + ++ ++ ++++++++++ + + GRAPHIC SCALE 100 0 50 100 200 N/F PAUL D. WHITLEY, JR. et al DB 972 PG 254 383013139352U ZONE: A-1 (FARM LAND/RESIDENTIAL USAGE) � +++*+*+'\ +' +++•\ + +++ +N. * +*+ + 4. +*+ *++ _+'._V.+ ..� CE4+ + ++ + + + + ++ + + ++ ,+ + + + + + + + , + +++ +++ t.4 + + + + + + + + Czi OUTSIDE CITY LIMITS 400 ( IN FEET ) 1 inch = 100 ft. BARTLETT ENGINEERING & SURVEYING, PC 1906 NASH STREET NORTH WILSON, N.C. 27893-1726 License No. C-1551 TELE: (252) 399-0704 FAX: (252) 399-0804 www.bartlett.us.com 44. 44. 41. 00.4 \\ •\ • • N/F \\— WINSTEAD FARMS, LLC --- DB 1835 PG 682 — 373905199138U-...—,-.— ZONE: R-30— i«^++ 1+ + ++., /t 1. + + 41 • .1+* +++ I +++ +, +i 1+*+ +++,I 1' ++ '• + +i i +++ 1 ««'«. +I +' 1+++ + / /'+,. * + P+ + ++ *i + / / + + / • kl i 4+ ,•r'•r.'+ ++ ++\++++++++++++++++++++++++++++++++++++++ +++++ + +++++++ + + +++•r••1 4. t +++++..« "r. -4* -tOC I10 10 + + + + �'+++ + + + + + + + + + + + NOTE: TEMPORARY ACCESS ROADS SHALL REMAIN IN PLACE UNTIL ANOTHER ACCESS POINT HAS BEEN PROVIDED AND APPROVED BY THE CITY OF ROCKY MOUNT FIRE DEPARTMENT. ++ + + r—'• '44_.+�+ *+++*�.*+* 4 4—+ + +4' + + + ++ OVERALL SITE PLAN + + +++ +++++ 4 + + + + + + + + + + + + + + + + + + + + + + + + + + + + + +`y.+ +++, zbN +R+'+*+++'+*+*++2b6"+++ + + +a/+++++ +*.AMEN+SI'AC +*+i.*+*+*+ +r+ +++ .r++ y% '•s'+••"-. +.—+• 4 y.*+ 7 + F=+= ; +'1++ + +4� +'1++ +" + +*+ ++ ++ . + + ++ +I. + + + + , +•i +++++1.++' + ++++ +1 + +i+y r + +� W« Iy+ s + +. + {.>,•'i + + +++ +++ +++ + • + + 1 ++++++ ^ +++A 'P 2OX.4+++++++�q++ ,4+++ V + =r+++/+++++++++++++++LOUAIIO ++ 4' ++ + • :; 4++ + :—..4 +++ + + + ,+ + • ++2++ 3—�_++*+ + ,n +*+ + + +++++ + ++++++++++ + + N/F FAYE P. CAPPS NO REFERENCE 383018302307 ZONE: A-1 (VACANT LOT) OUTSIDE CITY LIMITS FALL W RAY 27•e +9\+1\4�++\i ;. + *+1*+� ++++\\+* + \+ ,\++ 11 ++14++ ;++; + :\ ++1« ++I« I+ + + + IA i +f i +'°•1 + '++*+fioo�. + + +++++ =„fed ! + , 4 + 1 + + + + Q. +- + + T+* + Fib ` + + + ++ + •e•+ + .1 +1 + ++• 44 +.• +�+* 4 tt/++ +++ 4 • + + + <;' + + +v / +++++ ++ + • + + + +++++ + + + + .,\ + + + + + ++'+` 4/ +v*+ + + + +'+*+ + + + + + + + + +\. 1 + t+\+ + + + + + + * ++ + .• • +\., ++Zr +�+ ,i + + + ++++ # + +fit t+++ APPROX. + +I«+`\4` +1LOCATION • >+ �,,IY' 100—YR FLOOD +++ + + +a ;' ++,'; i ++'fir,'\9 i) • +// • • 7 + ,. Certification by the Department of Development Services that this construction plat was approved by the city planning board on day of 20 Director of Development Services Certlflcatlon by the City Engineering Department that this construction plat and required Improvement drawings meet the appropriate city standards. Director of Engineering OLDE MILL STREAM (PHASE 2) CITY OF ROCKY MOUNT, NC DATE: AUGUST 2020 SCALE(HORZ : 1)" = 100' SCALE(VERT): N/A REVISIONS: CRM 1ST REVIEW COMMENTS 10/13/2020 PROJECT: 20-042 CLIENT CODE: RHC CADFILE: 20042CP7 FIELD BOOK: DRAWN BY: RF SURVEY BY: KP, JB ROCKY NORTH PIN # MOUNT TWNSP CAROLINA NASH COUNTY ZONE: R-6 & 0-1 SHEET SP1 N O 0 N 9 0 N O 0 CD 0 i 0 CC 0 0 0 CZ i a SECTION OUTFALL TO POND 1 Sta. 19+45.62 PLAN VIEW A2 STA TOP INV. INV. A11 STA 10+43.51 (-12.25 L) TOP OF CURB = 127.57 INV. IN = 122.22 INV. OUT = 122.22 Al STA 10+43 44 (12.25 R) TOP OF CURB = 127.57 INV. IN = 122.10 INV. OUT = 122.10 A3 STA 19+45,03 (13.75 R) TOP OF CURB = 127.00 INV. IN = 121.26 (W) INV. IN = 121.90 (NW) INV. OUT = 121.26 (S) 19+45.03 (-13.75 L) OF CURB = 127.00 IN = 121.16 OUT = 12116 130 128 126 124 122 120 24 (MiN.) 118 116 28 LF 114 ®0 35% 112 110 N) 10 N 42" RCP IV 43LF -® 0.37% 42" RCP O N c0 CV • L-F 0:50'0 P 41 L -C§) O. 7% 30" "CP 8" P vC N N N � N u) N 0+00 148 146 144 142 140 140 138 138 136 136 134 134 132 132 130 130 128 128 126 126 124 124 122 122 120 120 118 118 116 116 114 114 112 112 110 110 108 1+00 1+36.06 i ' • __ may' ..•0., i i Md, co 3 \+ \+ + + `•.` \ -F \ + -1- + '•\ PROPOSED PROPOSED PROPOSED PROPOSED PROPOSED PROPOSED PROPOSED SYMBOL LEGEND CATCH BASIN SEWER MANHOLE FITTING GATE VALVE SEWER MANHOLE WATER HYDRANT WATER METER SEWER CLEANOUT •149z•I HI SEE SHEET CP3 CURVE TABLE CURVE LENGTH RADIUS DELTA TANGENT CHORD BRG. CHORD C1 88.57 1000.00 5'04'29" 44.31 S78'46'39"W 88.54 C2 181.71 500.00 20'49'23" 91.87 57045412"W 180.72 C3 384.17 500.00 44'01'20" 202.13 38210111"W 374.79 C4 608.63 970.00 35'57'02" 314.71 N5710137"W 598.70 200 63 i 198 197 SHADYBROOK DRIVE (60' R/W - 30' B/C TO B/C) PLAN VIEW 196 195 SEE SHEET CP5 GRAPHIC SCALE 194 50 0 25 50 100 200 ( IN FEET ) 1 inch = 50 ft. 125 126 • \, + + + + \, + + + -i- \. + + + \\- + + + \,+ + + ti9 J.-M + \ • \ ` • + •\ \'� + 189 • Certification by the Department of Development Services that this construction plat was approved by the city planning board on day of , 20 Director of Development Services Certification by the City Engineering Department that this construction plat and required Improvement drawings meet the appropriate city standards. Director of Engineering IGH PT STA 17+49.95 LOW PT STA: 19+45.04 LOW PT STA: 22+51.19 A6 IGH PT S6+122 LOW PT ELEV: 127.32 HIGH PT ELEV. 127.61 LOW PT ELEV: 126 83 IGH PT ELEV:TTA:7. : +• •. • PVI STA:19+61.70 PVI STA:22+46.79 STA 22+51.20 (-13.75 L) .- STA:2 VI STA:26+17.22 614 A4 - TOP OF CURB = 127.49 INV. OUT 123.50ELEV VI 29.04 STA 28+60.91 (13.75 R) PVI-ELEV'-t2�74 1.03 PVI ELEV:126.67 K:66.67 STA 20+20 28 R) PVI ELEV:127.19 (13.75 :100.00 :100.00 TOP OF CURB = 127.99 - LVC:-98.5 LVC:100.00 _ = - TOP OF CURB = 127.42 K:91.20 LVC:100.00 - NV. IN = 121.72 BVCS: 21+96.79 -` A5 VC:100.00 INV. IN = 124.10 BVCS: 19+11.70 STA 22+51.20 13.75 R)VCS: ( 25+67.22 INV. OUT = 124.10 0 • v; BVCE: 126.92 NV. OUT = 121.72 BVCE: 127.48 =VCE: 128.79 TOP OF CURB = 127.49 co EVCS: 20+11.70 EVCS: 22+96.79 VCS: 26+67.22 INV. IN = 123.10 (W) VCE: 128.79 B15 STA 27+89.26 R) EVCE: 127.17 EVCS: 127.44 INV. IN = 123.36 (S) INV. OUT 123.10 �� (13.75 PT STA: 21+13.34 A2HIGH TOP OF CURB = 128.34 - vi v • > STA 19+45.03 (-13.75 L) HIGH PT ELEV: 127.87 = (NE) A8 INV. IN = 124.46 613 STA 24+56.17 TOP OF CURB (13.75 = 128.40 R) INV. OUT = 124.46 STA 29+39.46(13.75 R) > TOP OF CURB = 127.00 - PVI STA:21+00.70 m NV. IN = 121.16 NV. = 12 TOP OF CURB = 127.59 PVI ELEV:128.06 A7IN NV. OUT = 121.16 STA 23+27.24 R) NV. OUT = 124.35 24. B16 NV. IN = 123.71 K. 62.64 (3.75 _ LVC:100.00 _ _ NV. OUT = 123.71 A3 BVCS: - TOP OF CURB = 127.76 STA 26+59.42 (13.75 R) A9 20+50.70 STA 19+45.03 TOP OF CURB (13.75 = 127.00 R) BVCE: 127.56 NV. IN = 123.72 NV. OUT 123 47 (W) STA 24+61.60 (38.12 R) TOP OF CURB = 128.99 I INV. IN = 121.26 (W) - EVCS: 21+50.70 = (E) _ NV. IN = 125.59 TOP OF GRATE = 128.00 NV. OUT = 125.09 ' INV. IN = 121.90 (NW) EVCE: 127.76 INV. OUT = 124.47 INV. OUT =. 121.26 (S) 0.50% _ � ����� 0 •. 1tC " .i. _ _� �"" r•■i ` iIIIi -�" _ -- PVC A'"L* •. 111 _�--- - ��E 0.50% 25 LF n 4 - ,�j�j� ��--- 1 MH#18 (5 D MANHOLE ) _F ®0 50% 5" RCP ®0.51 % - 136 24 R �.���� - i%%///`/�„��e ;= STA 24+59.69 (-6.25 L) MH#19 .(5'0 MANHOLE) �j �► 18 CP 15 RCP /ter/�%� 229 LF MH#17 (5'0 MANHOLE) TOP OF RIM = 128.13 STA 26+17.22 ��i _ _ _ _ _ _ 77 LF E . o INV IN = 112.82 TOP OF RIM = 128.91 MH#20 t1CY I V %_%/_ . m 1:7 '�F 8 DIP (AW A C900) '. STA 22+64.50 (-6.25 L) 28+91.93 L) .' .-�'• - I 80 LF 16 AWW• C150 �■ TOP OF RIM = 127.21 INV. OUT = 112.72 INV IN = 113.10 (NW) STA (-6.25 . � INV. IN = 112.48 INV IN = 119.08 (N) TOP OF RIM = 127.54 Q 24' (MIN.)- INV. OUT = 112.38 INV. OUT = 113.00 (E) INV. IN = 113.52 INV. OUT = 113.43 Q F- co -m, 4- F 8„ ��, 2% 18" PVC 1611111111.11111.1111111111111 -1 .1 I ®0. p -} L► 0 0.12% 18" P c L % 18 D MH#16 (5'0 MANHOLE) 1� �� 58,1 ��`�y- { STA 19+82.47 TOP OF RIM = 126.94 �I 282:5-tF 0 0.12%1: �/ ¢ r a - - - LIJ Ld • 4 - INV. IN = 112.88 (N) ala N -/n n.ln. INV. IN = 112.05 (SW) INV. OUT = 111.85 (S) O) CO ui N co 1- N c0 L'9Z £Z'LZ c0 d' _ 127.86 128.6 127.76 127.7 127.47 127.0 127.32 126.9 128.45 128.5 128.70 129.1 127.37 126.4 O t() O CO r (� 00 TO 00 0 N (0 O *- r co N N U) ao ^ oo N N to d. O r N N d- r; N N M N N N u) O m CO O N to N) Il) M co co O M d' '- a) 00 co W N N Ni N N oo r co r r ro cu of oo N N N N N N N N N N N N N N N N N N N N N N 16+00 17+00 18+00 19+00 20+00 21+00 22+00 23+00 24+00 25+00 26+00 27+00 28+00 29+00 148 146 144 142 140 138 136 134, 132 130 128 126 124 122 120 118 116 114 112 110 108 30+00 BARTLET " ENGINEERING & SURVEYING, PC 1906 NASH STREET NORTH WILSON, N.C. 27893-1726 License No. C-1551 TELE: (252) 3994-0704 FAX: (252) 399-0804 www.bartlett.us.com SHADYBROOK DRIVE PLAN & PROFILE Sta. 17+39 to Sta. 30+00 OLDE MILL STREAM (PHASE 2) CITY OF ROCKY MOUNT, NC DATE: AUGUST 2020 SCALE(HORZ): 1 : 50 SCALE(VERT): REVISIONS: CRM 2ND REVIEW COMMENTS 10/28/2020 CRM 1ST REVIEW COMMENTS 10/13/2020 1 : 5 PROJECT: 20-042 CLIENT CODE: RHC CADFILE: 20042CP7 FIELD BOOK: DRAWN BY: RF SURVEY BY: KP, JB ROCKY MOUNT TWNSP NASH COUNTY NORTH CAROLINA PIN # ZONE: R-6 & 0-1 SHEET CP1 0 N N N a 0 0 0 061 ad- 0 0 N 0 S i 0 0 0. 150 148 146 144 142 44, to A SYMBOL LEGEND PROPOSED CATCH BASIN PROPOSED SEWER MANHOLE PROPOSED FITTING GATE VALVE PROPOSED SEWER MANHOLE PROPOSED WATER HYDRANT PROPOSED WATER METER PROPOSED SEWER CLEANOUT EXISTING WATER LINE EXISTING SEWER UNE 186 127 611 0 CURVE TABLE CURVE LENGTH RADIUS DELTA TANGENT CHORD BRG. CHORD C5 278.80 I 450.00 3514'35" 142.93 N21.54.49"W 272.45 128 N 184 1 1 m SEE SHEET CP6 183 j Om Om 0 SHADYBROOK DRIVE (60' R/W - 30' B/C TO B/C) PLAN VIEW LOW PT STA: 30+77.69 LOW PT ELEV: 126.80 PVI STA:31+32.33 PVI ELEV: 126.46 K: 50.00 1 LVC: 159.29 BVCS: 30+52.69 BVCE: 126.86 EVCS: 32+11.98 EVCE: 128.60 B5 STA 34+26.14 (13.75 R) TOP OF CURB = 134.49 INV. IN = 130.64 INV. OUT = 130.44 B12 STA 30+77.69 (-13.75 L) TOP OF CURB = 126.96 INV. OUT = 123.90 136 B11 STA 30+77.69 (13.75 R) TOP OF CURB = 126.96 INV. IN = 123.03 (SE) INV. IN = 123.76 (SW) INV. OUT = 122.53 (NW) 128 126 124 122 120 118 116 64 STA 32+6615 (13.75 R) TOP OF CURB = 130.22 INV. IN = 121.60 (SE) INV. IN = 126.43 (NW) _ INV. OUT = 121.60 (SW) 8i STA 31+50.24 (13.75 R) TOP OF CURB = 127.49 INV. IN = 122.67 (NE) INV. IN = 122.17 (SE) INV. OUT = 122.17 (NW) B3 _ STA 32+65 81 (-13.75 L) TOP OF CURB = 130.21 INV. IN = 121.47 INV. OUT = 121.47 HIGH PT STA: 35+06.24 HIGH PT ELEV 135.66 PVI STA:34+56.24 PVI ELEV:135.16 K•5932 LVC: 100.00 BVCS: 34+06.24 BVCE: 133.82 EVCS: 35+06 24 EVCE: 135.66 103 167 SEE SHEET CP3 50 SEE SHEET CP3 0 25 tt 93 W 50 itt N V 707 146 GRAPHIC SCALE 50 100 41 TEMPORARY BARRICADE 200 ( IN FEET ) 1 inch = 50 ft. B33 STA 37+31 17 (-13.75 L TOP OF CURB = 138.08 INV. IN = 133.99 INV. OUT = 133.79 B6 STA 35+40.72 (13.75 R) TOP OF CURB = 136.17 INV. OUT = 132.27 634 STA 37+31.20 (13.75 R) TOP OF CURB = 138.08 INV. OUT = 134.13 rig' Misr siSi omassaA •L•. 136 LF ® 0.50% 72LF • •• • " •1 154 LF 6" PV ATER 114 300.0 LF 0 O.0 % 18" PVC 112 110 cri 1 MH#21 STA 31+91.22 (-7.39 L TOP OF RIM = 127.94 INV. IN = 113.98 INV. OUT = 113.88 0 15 A RCP MH#23 STA 34+92.05 TOP OF RIM = 135.50 INV. IN = 122.07 INV. OUT = 121.75 15 RCP- MH#22 (5'0 MANHOLE) STA 33+91.37 TOP OF RIM = 133.42 INV. IN = 115.72 (N) INV. IN = 114.42 (W) INV. OUT = 114.22 (SE) MH#25 (5'0 MANHOLE) STA 38+35.48 TOP OF RIM = 138.95 INV. OUT = 123.45 8 • ras MH#24 (5'0 MANHOLE) STA 36+90.68 TOP OF RIM = 137.51 INV. IN = 123.07 (W) INV. IN = 122.88 (N) INV. OUT = 122.87 (S) t7 N co (13(d N d' d to 00 (d CO M d N T 0) N 0) d to 0) M ND N co tri 0) co t\ M (0 PO 0) O txi to N v) 00 to V) O 10 O o) O co 00 N) 30+00 31+00 `TWA SEAL , \� 20106\V� 32+00 33+00 BARTLETT ENGINEERING & SURVEYING, PC 1906 NASH STREET NORTH WILSON, N.C. 27893-1726 License No. C-1551 34+00 TELE: (252) 399-0704 FAX: (252) 399-0804 www.bartlett.us.com 35+00 36+00 SHADYBROOK DRIVE PLAN & PROFILE Sta. 28+00 to Sta. 38+43 37+00 150 148 146 144 142 140 138 136 134 132 130 128 126 124 122 120 118 116 114 112 110 38+00 38+42.99 • Certification by the Department of Development Services that this construction plat was approved by the city planning board on _ day of 20 Director of Development Services Certification by the City Engineering Department that this construction plat and required Improvement drawings meet the appropriate city standards. Director of Engineering 25' PRIVATE DRAINAGE EASEMEN OUTFALL #1 TO POND 2 PLAN VIEW 150 148 146 144 142 140 138 136 134 132 130 128 126 124 122 120 118 116 114 112 110 O tri N B4 STA TOP INV. INV. INV. 1+87.75 OF IN IN OUT CURB = 130.22 = 121.60 (SE) = 126.43 (NW) = 121.60 (SW) , , B3 STA 1+60.25 TOP OF CURB = 130.21- INV. IN = 121.47 INV. OUT = 121.47 B2 STA 0+32.25 TOP OF GRATE = 128.93 INV. IN = 120.83 INV. OUT = 120.83 'r 8" PVCf1 Val �' ll / 1 r 8 LF © 0. O% 36" KC 32 LF 0 0.50% V © 0.40r0 36" 'CP IV 18" PVC 18 PVC- ((0 M to N <ON O N. N Nry N f.53 Otto tO '_ 0+00 1+00 OLDE MILL STREAM (PHASE 2) -• CITY OF ROCKY MOUNT, NC 150 148 146 144 142 40 138 136 134 132 130 128 126 124 122 120 118 116 114 112 110 1+87.75 150 148 146 144 142 140 138 136 134 132 130 128 126 124 122 120 118 116 114 112 110 O n SEE SHEET CP5 33 m 7 Ian CB 7810' TO CB '87 PLAN VIEW 610 STA TOP 3+49.31 OF CURB = 138.27 INV. OUT = 134.36 1 89 STA 3+24.81 TOP OF CURB = 138 27 5-LF 0:50'. INV. IN = 134.24 " 1 RCP INV. OUT = 133.99 I I _...ri, w atUilir.Slarl Pr �• 2 6 B8 STA 1+49.76 TOP OF GRATE = 131 44 B7 I INV. IN = 127.70 STA 0+00.00 INV. OUT = 127.20 ' • TOP OF CURB = 127.49 INV. IN 122.67 = 122.17 (NE) 5 1E) INV. OUT 122.17 (NW) 127.23 128.5 1 to N com 136.35 138.1 r) t00 oO to to to to TMO 4 .N- 0+00 DATE: AUGUST 2020 SCALE(HORZ): 50 SCALE(VERT): 1 : 5 PROJECT: 20-042 CLIENT CODE: RHC CADFILE: 20042CP7 FIELD BOOK: DRAWN BY: RF SURVEY BY: Kip, JB 1+00 ROCKY NORTH 2+00 150 148 146 144 142 140 138 136 134 132 130 128 126 124 122 120 118 116 114 112 3+00 3+49.31 MOUNT TWNSP NASH COUNTY CAROLINA ZONE: R-6 & 0-1 1. 1- 0 N 0 1 0 Z 0 0 0 N 0 0 0 0 i U S i it D. 0 0 t REVISIONS: CRM 2ND REVIEW COMMENTS 10/28/2020 & CRM 1ST REVIEW COMMENTS 10/13/2020 PIN # SHEET CP2 a: • X X\ x .x......;" x�x X X i %�X X x x \ X x• X X • X j X i� \� X X X X .-x' x \x X X X X X X X N X X X X x flXi�X x x X x x x X x X x X X x `X x XN>? x �\ � X X X x \ \ �® \ © Q� X X X X x X X x X x \ /x x x x �/ \ JCi s X X x SYMBOL LEGEND •x, \ x X PROPOSED CATCH BASIN PROPOSED SEWER MANHOLE PROPOSED FITTING GATE VALVE PROPOSED SEWER MANHOLE PROPOSED WATER HYDRANT PROPOSED WATER METER PROPOSED SEWER CLEANOUT EXISTING WATER LINE EXISTING SEWER LINE XI x -I x x Xi x xi x1 X x1 T x X \ x X X 1 r 4 X I j x k 1' .1 It • N • 4 • CURVE TABLE CURVE LENGTH RADIUS DELTA TANGENT CHORD BRG. CHORD C6 176.98 500.00 2016'50" 89.43 N31'25'30"W 176.06 •� n x X X \X X•.. x X X X x n X X X X X i X .X X X \ k\ X x x X X X X X X X X X X * X �C x X X x x\\\QPA X X X x X X X x x x \x X X X X X X X X Xi• I �C X X '\ \ X X x X f X X, X X \ \\ X\\ X X x x GA 0 ��x\ x` X X X X x x x X X X X X X X X%% v X X \\ x \� x X� x X x ;X X `X` `z X X X/ x X X X X x �. X x\ X x\\ X QP 2` X X X X\`� / x x \�\O\x0 X X\ x X X X `X \x.`X x X/ x x x X x x \ X X X x X \\ 1 x x X X X X x x x\\ x X x X x�x - `Yc X1 X X X X X x x X \x x )x\ ,et X x X 11 X \ X X x X X x X x x x x x x\\x x\X•` \x x x x\ ... 1 x X X X X x x X X X x x X x\\` ` x„ x X x\ x X X X� X X X x x x X X X\x`\x`\ x X X x x X x x X X x X X x x X X X X X x z61- f1��c x x e \%VVj�1l�V x X X x X X X X X x/ ,\n x X X X x/ X , i. X /x \s C, \ �� A\«\ I. / 4' 1 1/ \ 1 1 1 • 1 1 V� •\ \ _ X \\ \\ • X X X X\x: X X >t \ X I X X \ \ iSl1_.X�..>F. •i 7X x x x\•� \\ ,\ Vc • // X X X /T /C x /x < \. \ \ J X x. X X X x/ X X ..i X /. g"si\ � x x x. x X X\ * 11 x x X X \\ \\ .\� r\ x' x x xX x\ \ Ix •\ \\\ I' x �'• 1 l\ • • V9 / • ..........4.1,,,I.... X ci:X .....XTVX X \ ....:91\ ��S.i Isx0O\,O4' SANITARY SEWER OUTFALL PLAN VIEW SEE SHEET CP1 Al cn 0 asalai 4 IC Certification by the Department of Development Services that this construction plat was approved by the city planning board on day of 20 Director of Development Services Certification by the City Engineering Department that this construction plat and required Improvement drawings meet the appropriate city standards. Director of Engineering SEE SHEET CP5 IrlAa I I I III I I I I I II I M 1.1g II le 11Nrege• 1• I 01 133 82 ao SHADY CREST ROAD PLAN VIEW 716 0 25 17,4 /00 GRAPHIC SCALE 50 100 flA 200 14 13 13 134 132 130 128 126 124 122 120 11 108 106 104 102 100 _ .,, __________y, 10+00 11+00 12+00 BARTLETT 13+00 ENGINEERING & SURVEYING, PC 1906 NASH STREET NORTH License No. C-1551 www.bartlett.us.com 14+00 15+00 SANITARY SEWER OUTFALL & SHADY CREST RD PLAN & PROFILE 16+00 140 138 136 134 132 130 128 126 124 122 120 118 116 114 112 110 108 106 104 102 100 17+00 146 144 .142 140 138 136 134 132 130 128 126 124 122 12C 11E 114 11 110 108 106 • Al 0 TOP OF CURB 127.57 All 41 LE INV. OUT 122.22 MH#16 (5 0 MANHOLE) STA 19+82.47 TOP OF RIM = 126.94 cv ge- CO STA 12+67.25 (12.25 R) TOP OF CURB = 129.80 TOP OF CURB = 129.80 INV. OUT 124.52 pvo 23. ai cv TOP OF CURB = 131.20 81 LF 24” Re A20 STA TOP INV. INV. A23 TOP OF CURB = 133.70 OF CURB = 132.00 aseaumwil.S.°."w'arr:/:CIIIIIIIIIISilingl. alliere.„ 206 ci MH#26 STA 13+02.21 (6.14 R) MH#27 STA 14+47.53 NV. IN 124.82 A21 TOP OF CURB = 133.10 A22 TOP OF CURB 133.10 MH#28 STA 16+47.53 146 144 142 140 138 136 132 ai ro to CO it co GI 147) mt 130 128 126 124 122 120 118 116 114 112 110 108 106 to ton r. 10+00 11+00 12+00 OLDE MILL STREAM (PHASE 2) CITY OF ROCKY MOUNT, NC 13+00 DATE: AUGUST 2020 SCALE(VERT): 14+00 PROJECT: 20-042 CLIENT CODE: RHC CADFILE: 20042CP7 FIELD BOOK: DRAWN BY: RF SURVEY BY: KP, JB 15+00 16+00 ROCKY MOUNT TWNSP NORTH CAROLINA NASH COUNTY CRM 1ST REVIEW COMMENTS 10/13/2020 SHEET CP3 tn 0 0 CL o re • • 88 • SYMB01 LEGEND PROPOSED CATCH BASIN PROPOSED SEWER MANHOLE PROPOSED FITTING GATE VALVE PROPOSED SEWER MANHOLE PROPOSED WATER HYDRANT PROPOSED WATER METER PROPOSED SEWER CLEANOUT EXISTING WATER UNE EXISTING SEWER UNE d • • 4) • • s *• i. G• ti 0b1y '1 X 111 CURVE TABLE CURVE LENGTH RADIUS DELTA TANGENT CHORD BRG, CHORD C7 230.14 250.00 52144141" 123.95 N67'56'15"W 222.10 SEE SHEET CP5 2 IS OLX 0l• SEE SHEET CP2 TEMPORARY BARRICADE SHADY CREST ROAD (46' R/W - 27' B/C TO B/C) PLAN VIEW 50 0 1N3W3SV3 25 30VNIV21O 3J VAYri ,gl1VMS 159 GRAPHIC SCALE 50 100 158 B27 ilhatmeonto 157 200 ( IN FEET ) 1 inch = 50 ft. LB27 02# 31VMS Certification by the Department of Development Services that this construction plat was approved by the city planning board on _ day of 20 Director of Development Services Certification by the City Engineering Department that this construction plat and required improvement drawings meet the appropriate city standards. Director of Engineering 152 150 148 146 144 142 140 138 136 134 132 130 128 126 124 122 120 118 116 114 112 N 1rj HIGH PT STA: 23+85.30 LOW PT STA: 27+23.78 LOW PT STA: 29+97.79 828 HIGH ELEV: 140.59 LOW PT ELEV: 132.50 LOW PT ELEV: 135.02 STA 30+31.95 832 PVI STA: 29+97.79 (-27.45 L) PVI STA:24+02.84 STA 26+16.37 R) f1Vl-STA-26+/.5.18 ELEV: TOP OF CURB = 133.08 - A26 A (12.24 PVI 132.28 PVI ELEV:140.94 P ELEV 135. f2 TOP OF CURB = 136.86 - 00 K:45.00 INV. IN = 127.52 STA 17+82.58 (12.25 R)A31 20+45.87 R) A28 (12.25 K: 35.02 e TOP OF CURB = 134.94 _STA _ INV. IN = 132.96 C•ion LVC:90.00 INV. OUT = 127.32 STA 19+40.89 (-12.25 L) OF CURB = 137.57 LVC:105.00 VKA I V�•1I1f100 1 INV. OUT = 131.02 _-TOP INV. IN = 133.66 INV. OUT = 132 74 BVCS: 29+52.79 TOP OF CURB = 136.52 BVCS: 23+50.34 A32 ao a INV. IN = 132.58 -INV. OUT = 133.46 BVCE: 132.73 BVCE: 140.41+5EVCS: 30+42.79 B29 A25 21+73 87 (12.25 R) - INV. IN = 132.48 _STA + `� `� `� EVCE: 132.73 STA 29+97.79 (-12.27 L) STA 17+82 58 (-12.25 L) INV. OUT 132.33 A30 TOP OF CURB = 138.85 EVCS: 24+55.34 = EVCE: 139.89 TOP OF CURB = 132.70 - INV. OUT = 134.94 TOP OF CURB = 134.94 1 I STA 20+45.87 (-12.25 L) INV. IN = 130.67 A29 - TOP OF CURB = 137.57 -R d r•� v INV. IN = 127.91 INV. IN = 130.90 STA 19+40.89 (12.25 R) INV. IN = 133.34 INV. N W OUT = 127.71 cN1 m STA 28+55.95 (12.23 R) INV. OUT = 130.67 TOP OF CURB = 136.52 - INV. OUT = 133.34 - m w TOP OF CURB = 133.89 - B30 INV. OUT = 132 61 - _ INV. IN = 129.99 29+97.79 (12.23 R) - `2.bp� INV. OUT = 129.96 TOP OF CURB = 132.70 INV. IN 128 54 a e�lY� ._ = INV. OUT = 128.04 _ C9601: AW �_ 128 LF uv. till =11al ---� - r.r_ :yam- 15' RCP -_ -_- c 0.75% _ 1'" RCP ■ (MIN.) 24C LF -" ---------...r.-__ ---� _ - _�.ra_<.,i<�r.>TAT ® 1.15% --- -� �� -- 0 0 .: - d _^ 15" RCP 142 42 LF 123.3 LF . MH#32 ..OB�o1 N- I. _: STA 24+87.38 -4 LE 00% w G. TOP OF RIM = 139.25 _ 2J.0l 15" RAP 24" (MIN.) _ I INV. OUT = 134.25 • • 15" A24 MH#31 - PVG L-r 0 0.40g - 4 a - STA 17+18.14 (-12.25 L) MH#29 MH#30 STA 22+67.38 240• ;•, , �, _ _ STA RI CUR STA 18OF (6.22134. R) -TOP 19+68.21 OF RIM (13659)TOP INV. IN 131.22 NV. IN 0.03134.30 _ (W)8 INV. OUT = 130.03 TOP OF RIM RIM = 134.59 INV. IN = 128.52 INV. IN = 129.92 (S) MH#34 - INV. IN = 12128.8.02 MH#33 STA 30+59.27 INV. OUT 128.02 INV. OUT = 128.52 INV. OUT = 129.72 (E) STMHA 3624+90.68ANHOLE) _ = TOP OF RIM = 137.51 - STA 28+14.38 TOP OF RIM = 132.89INV. TOP OF RIM = 134.11 INV. IN 123.07 OUT = 125.10 A27 = (W) INV. IN = 124.13 STA 18+40 78 (-12.25 L) INV. IN = 122.88 (N) INV. OUT = 124.03 - TOP OF CURB = 135.52 INV. OUT = 122.87 (S) INV. IN = 131.29 INV. OUT = 131.29 140.41 142.1 133.26 134.1 N M. N rn N N Nd• M N N N N O �t' '- O) d' O (0 0) D) O Cn to co co c0 c0 O c0 O I„T '- to '- O) O O) m 't 0) 7 lit W t` W O O O) N a) cn t7 M O 00 M M O I r M 0 O 6 co. N) r Cl ro ui Ln to r7 t\ t1') 4 d- M 1"0 N O d: <t• t'') M r 1+j d M 1- O CV d M 1") Lo° •- a0 d �I t� M M to G) co 00 OD O 6 O .t: Eli ai co co 1� 0J Oi Cp Oi Di N Di ri M r'0 M d: M M M to tfi r7 N] M to rr) I"0 M M I< M M M M M t+7 r7 M d- O cl- M �t 17+00 aa;;r $ B PR�v` gnu 1111 18+00 19+00 20+00 BARTLE'TT ENGINEERING & SURVEYING, PC 1906 NASH STREET NORTH WILSON, N.C. 27893-1726 License No. C-1551 21+00 TELE: (252) 399-0704 FAX: (252) 399-0804 www.bartlett.us.com 22+00 23+00 SHADY CREST ROAD PLAN & PROFILE Sta. 17+00 to Sta. 30+59.27 24+00 25+00 26+00 27+00 OLDE MILL STREAM (PHASE 2) - CITY OF ROCKY MOUNT, NC - 28+00 29+00 DATE. AUGUST 2020 SCALE(HORZ): 1 : 50 SCALE(VERT): REVISIONS: CRM 2ND REVIEW COMMENTS 10/28/2020 CRM 1ST REVIEW COMMENTS 10/13/2020 1 : 5 30+00 PROJECT: 20-042 CLIENT CODE: RHC CADFILE: 20042CP7 FIELD BOOK: DRAWN BY: RF SURVEY BY: KP, J8 152 150 148 146 144 142 140 138 136 134 132 130 128 126 124 122 120 118 116 114 112 30+60 ROCKY MOUNT TWNSP NASH COUNTY NORTH CAROLINA ZONE: R-6 & 0-1 PIN # SHEET CP4 11:10AM EST 0 i CURVE TABLE CURVE LENGTH RADIUS DELTA TANGENT CHORD BRG. CHORD C8 I 128.40 250.00 29'25'40" 65.65 N33'43115"E 127.00 SEE SHEET CP1 SYMBOI I FGEND PROPOSED CATCH BASIN PROPOSED SEWER MANHOLE PROPOSED FITTING GATE VALVE PROPOSED SEWER MANHOLE PROPOSED WATER HYDRANT PROPOSED WATER METER PROPOSED SEWER CLEANOUT EXISTING WATER UNE EXISTING SEWER LINE 150 148 146 144 142 140 138 136 134 132 130 41 LF 12 ® 0.50% 18" RCP IV 12 12 12 12 11 11 1 112 110 SEE SHEET CP1 • • 110•11 y� T • SAND PEBBLE PLACE (46' R/W - 27' B/C TO B/C) PLAN VIEW 50 0 25 SEE SHEET CP3 SEE SHEET CP3 GRAPHIC SCALE 50 100 200 ( IN FEET ) 1 inch = 50 ft. HIGH PT STA: 14+67.53 HIGH PT STA: 11+67.85 HIGH PT ELEV: 133.52 HIGH PT ELEV: 130.83 PVI STA:14+82.53 ELEV:133.97 PVI STA:11+17.85 KPVI 0 PVI ELEV:130.33 LVC:1 LVC:150.00 _ STA STA 16+14.78 L) (-12.25 K: 427.43 BVCS: 14+07.53 TOP OF CURB = 131.69 617 STA 10+42.80 L LVC:100.00 BVCS: 10+67.85 BVCE: 133.22 INV. OUT = 128.28 (-12.25 EVCS: 15+57.53 TOP OF CURB = 129.60 BVCE: 129.71 _ -_ EVCS: 11+67.85 EVCE: 132.85 A18 INV. IN = 125.79 STA 16+14.78 (12.25 R) INV. IN = 126.33 EVCE: 130.83 TOP OF CURB = 131.69 - INV. OUT = 125.79 INV. IN 128.16 B20 = B19 B18 STA 11+67.85 (-12.25 L) STA 12+68.52 (-12.25 L) INV. OUT = 127.96 STA 10+42.80 R) - (12.25 - TOP OF CURB = 131.02 TOP OF CURB = 132.03 TOP OF CURB = 129.60 INV. IN = 127.11 _ INV. OUT = 128.11 INV. OUT = 126.45 INV. OUT = 126.86 -�- -- __ -1.50% al is .. --...tea i - LA20 y"__ _ �-' E MH#37 (MIN.) �� STA 15 27 TOP OF RIM OF = 133.38 • "" MH#36 INV. OUT = 127 83 "' STA 12+69.34 L) (-1.19 TOP OF RIM = 131.82 MH#27 STA 14+47.53 INV. INV. IN = 126.28 OUT = 126.18 TOP OF RIM = 131.40 I INV. IN = 124.82 (NW) MH#35 INV. OUT = 124.71 (SE) _ STA L) (130.8 TOP RIM- OF RIM = 130.87 MH#19 (5'0 MANHOLE) INV. INV. N = 125.22 OUT = 125.12 STA 26+17.22 J TOP OF RIM = 128.91 - INV. IN = 113.10 (NW) - INV. IN = 119.08 (N) INV. OUT = 113.00 (E) 130.65 132.5 133.50 134.5 I"�d�• O to 0N0 N m. N. rn T d-Lcp m M d'O�i N �d O N, N M M 4 ; d' N n, Op of C) N [V 17 n1 cv M N) - T r 17 r t7 t7 ^ M N) { 10+00 11+00 12+00 13+00 BARTLETT ENGINEERING & SURVEYING. PC 1906 NASH STREET NORTH WILSON, N.C. 27893-1726 license No. C-1551 TELE: (252) 399-0704 FAX: (252) 399-0804 www.bartiett.us.com 14+00 15+00 16+00 SAND PEBBLE PLACE & BUBBLING BROOK LANE PLAN & PROFILE 150 148 146 144 142 140 138 136 134 132 130 128 126 124 122 120 118 116 114 112 110 SEE SHEET CP4 156 154 152 150 148 146 144 142 140 13 13 13 13 13 128 126 124 122 120 118 116 CURVE TABLE CURVE RADIUS DELTA TANGENT CHORD BRG. CHORD LENGTH C9 221.71 300.00 42'20'36" 116.19 S25'27'50"E 216.70 C10 57.31 100.00 32'50'12" 29.47 S63'03114"E 56.53 SYMBOL IEGEND PROPOSED CATCH BASIN PROPOSED SEWER MANHOLE PROPOSED FITTING GATE VALVE PROPOSED SEWER MANHOLE PROPOSED WATER HYDRANT PROPOSED WATER METER PROPOSED SEWER CLEANOUT EXISTING WATER LINE EXISTING SEWER UNE SEE SHEET CP4 • s4SI.l 75!? \SF _. % 414l t\�i► BUBBLING BROOK LANE (46' R/W - 27' B/C TO B/C) PLAN VIEW LOW PT LOW PT STA: ELEV: 13+13.22 138.08 PVI STA:13+39.07 PVI ELEV:137.89 610 K:48.29 _ STA 13+13.22 (-12.25 L) LVC:100.00 _ TOP OF CURB = 138.27 - BVCS: 12+89.07 BVCE: 138.14 INV. OUT = 134.36 EVCS: 13+89.07 EVCE: 138.67 89 STA 13+13.22 (12.25 R) TOP OF CURB = 138.27 INV. IN = 134 24 INV. OUT = 133.99 1 57 0 -0.5()% 4 - TO F Sb MN ( , ) HYDRFNT --� 8 PVC A W .91/ - __fi,'1 LF-® 0`4)7-8"-PVC v 37 6 LF 0 0.40% 8" PVC MH#43 MH#42 - MH#31 STA 12+47.83 (5.19 R) STA 13+96.65 TOP OF RIM (20 59 R) = 138.76 - STA 22+67.38 TOP OF RIM = 139.58 TOP OF RIM = 138.24 - INV. OUT = 131.74 - INV. INV. IN = 131.22 (W) IN = 131 12 - INV. IN = 129.92 (S) INV. OUT = 131.02 _ INV. OUT = 129.72 (E) _ MH#41 STA 11+36.98 (5.19 R) TOP OF RIM = 138.79 INV. IN 130.57 = INV. OUT = 130.47 co to 138.83 141.5 to W M Lc) O H) O N to 0? to . O N N oo n <t co r M to M •`• to tor 10+00 11+00 12+00 OLDE MILL STREAM (PHASE 2) - CITY OF ROCKY MOUNT, NC 13+00 DATE. AUGUST 2020 SCALE(HORZ): 1 : 50 SCALE(VERT): REVISIONS: CRM 2ND REVIEW COMMENTS 10/28/2020 1 : 5 14+00 156 154 152 150 148 146 144 142 140 138 136 134 132 130 128 126 124 122 120 118 116 1 Certiflcatlon by the Department of Development Services that this construction plat was approved by the city planning board on _ day of , 20_. Director of Development Services Certiflcatlon by the City Engineering Department that this construction plat and required improvement drawings meet the appropriate city standards. Director of Engineering PROJECT: 20-042 CLIENT CODE: RHC CADFILE: 20042CP7 FIELD BOOK: DRAWN BY: RF SURVEY BY: KP, JB ROCKY MOUNT TWNSP NASH COUNTY NORTH CAROLINA ZONE: R-6 & 0-1 PIN # SHEET CP5 a rbk N 0 m v 0 0 0 0 0 0 0 0 0 3- U ye 0 a i u: • Certification by the Department of Development Services that this construction plat was approved by the city planning board on , day of _ . 20_. mo a ti 70 coo 01. to m CURVE TABLE CURVE LENGTH RADIUS DELTA TANGENT CHORD BRG.ICHORD C11 33.56 150.00 12'49'05" 16.85 S79'17'S6"W JI 33.49 82 A 0 lb DI I I SEE SHEET CP2 SYMBOL LEGEND PROPOSED CATCH BASIN PROPOSED SEWER MANHOLE PROPOSED FITTING GATE VALVE PROPOSED SEWER MANHOLE PROPOSED WATER HYDRANT PROPOSED WATER METER PROPOSED SEWER CLEANOUT EXISTING WATER UNE EXISTING SEWER LINE 15 15 14 14 14 142 140 138 136 134 13 13 12 12 12 2 12 11 11 11 112 u0 tri to 164 • •4•z• 165 14+00 w 166 167 168 w L625 24" RCP IV 169 RcP 825 w 170 SHADYBROOK COURT (46' R/W - 27' B/C TO B/C) 5� PLAN VIEW 0 25 172 GRAPHIC SCALE 50 100 L825 24" RCP 0) rn 0 0 m n m 0 SECTION / OUTFACE 2 TO POND 2 Sta. 14f5272 PLAN VIEW 200 ( IN FEET) 1 inch = 50 ft. P-VI-S k-11-+•-10,-59 PVI F V 130.58 1: 66 82 B21 LV' 105.00 STA 14+52.72 (-12.25 L) o o o - TOP OF CURB = 127.63 � a INV. IN = 123.29 (2-24") 00 r o ui ) CUU INV. OUT = 122.79 (30') r r - 822 STA o - LOW PT STA: 14+52. 0 1i r 0 LOW PT ELEV 127. 51 - 14+52 72 (12.25 R) TOP OF CURB = 127.63 m B23 th w STA 12+86.82 (12.25 R) PVI STA:14+46.68 PVI ELEV:127.22 --- IN = 123.54 (W) cow ---INV. INV. IN = 124.27 (E) TOP OF CURB = 129.01 - K' 56 12 INV. IN = 125.10 LVC:100.00 _ INV. OUT = 123.42 (2-24") (S) INV. OUT = 125.10 BVCS: 13+96.68 STA 14+71.31 (12.48 R) BVCE' 127.72 - = TOP OF CURB = 129.09 824 '25�9.- STA 11+64.72 (12.25 R) EVCS: 14+96.68 EVCE: 127.61 - - INV. = 1 3.4 _ INV. OUT = 7.74 TOP OF CURB = 130.23 - INV. OUT = 126.32 -1 00% 3s"-(MI •. 900 I0 - Mt{#22R (5'0 MANHOLE) HroR Nr 1-22-LF STA 33+91.37 __ - TOP OF RIM = 133.42 © 1.00% 16Fi 1 P-- _ INV. IN = 115.72 (N) 15" RCP ®0.50% 19 LF MH#40 INV. IN = 114.42 (W) MH#38 15" RCP 1 ®" 10% STA 6 3 INV. OUT = 114.22 (SE STA 11+11.40 L) (-0.95 MH#39 RCP IV TOP RIM TOP OF RIM = 130.75 STA 14+11.33 INV. IN = 114.65 TOP OF RIM = 127.59 24" (MIN.)- INV. OUT 115 INV. OUT = 114.55 NV. IN = 115.11 INV. OUT = 115.01 111----5 LF 0 019% 18" PVC 300.0 LF 0 0.12% 18" PVC 2351 LF O O 4% tB" rvc 130.98 130.2 128.68 128.0 128.18 127.9 127.68 128.2 0r to r re)c0 conNI- O p o N W r` N N- •- c co r W N N M rri rr) r r7 t) .- d N of N , N N .- .M- r ,- •- 10+00 11+00 12+00 13+00 BARTLETT ENGINEERING & SURVEYING, PC 1906 NASH STREET NORTH WILSON, N.C. 27893-1726 license No. C-1551 14+00 TELE: (252) 399-0704 FAX: (252) 399-0804 www.bortlett.us.com 15+00 SHADYBROOK CT PLAN & PROFILE 16+ 150 148 146 144 142 140 138 136 134 132 130 128 126 124 122 120 118 116 114 112 110 822 STA 1+93.75 (0.00 ) TOP INV. OF CURB IN = 123.54 = 127.63 - INV. IN = 124.27 INV. OUT = 123.42 821 STA 1+69.25 (0.00 ) TOP OF CURB = 127.63 INV. IN = 123.29 INV. OUT = 122.79 - - 25 LF ® 0.51% 24" RIP I11011.1 11 r 8" PVC WATER 1 CRADLE 18" "VC-__ O O t0 N N •c• N Na) d- N 1- 0+00 1+00 150 148 146 144 142 140 138 136 134 132 130 128 126 124 122 120 118 116 114 112 110 ro 1+93.75 OLDE MILL STREAM (PHASE 2) CITY OF ROCKY MOUNT, NC Director of Development Services Certification by the City Engineering Department that this construction plat and required improvement drawings meet the appropriate city standards. Director of Engineering 150 148 146 144 142 140 138 136 134 132 130 128 126 124 122 120 118 116 114 112 110 cO r NC awn NAn 88/88 API CB#8 TO CB#5 PLAN VIEW B28 STA 2+83.15 - B26 TOP OF CURB = 133.08 - STA 1+49.05 TOP OF (0.00 ) RIM = 129.82 INV. INV. IN = 127.52 (NE) OUT 127.32 = (S) INV. IN = 125.53 (N) INV. IN = 126.57 (E) INV. OUT = 125.53 (S) .34% 2--4 ,1RC= 41` 9-L ®1.20-% L c - 075e -�= I 2 . " RCP - B25 STA 0+00.00 - - - TOP OF CURB (0.00 = 129 ) 09 _ INV. IN = 123.74 INV. OUT = 123.74 131.63 133.4 cn 0co N ,r- N 129.8 132.E tto 00 N N M r 1 to 0+00 DATE: AUGUST 2020 SCALE(HORZ): 1 : 50 SCALE(VERT): 1 : 5 1+00 PROJECT: 20-042 CLIENT CODE: RHC CADFILE: 20042CP7 FIELD BOOK: DRAWN BY: RF SURVEY BY: KP, JB 2+00 150 148 146 144 142 140 138 136 134 132 130 128 126 124 122 120 118 116 114 112 110 0 a7 N r 2+83.15 ROCKY MOUNT TWNSP NASH COUNTY NORTH CAROLINA ZONE: R-6 & 0-1 REVISIONS: CRM 1ST REVIEW COMMENTS 10/13/2020 PIN # SHEET CP6 g UI a 80 0 40 GRAPHIC SCALE 80 180 ( IN FEET ) 1 inch = 80 ft. FIRE HYDRANT FIRE HYDRANT + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + 4 + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + 4. + + + + + + + + + + • SYMBOL LEGFND - + + + + + t + + + + + + + + + + + + + + + + + + + + + + + 4 } + + + + + + + + + + + + + + + + + +. + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + 4. + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + +- + + + + + + + + + + + + + + + + + + + + + + + + + + OUTSIDE CITY LIMITS 320 FIRE HYDRANT PRIVATE DRAINAGE FIRE HYDRANT POND 2 PROPOSED SEWER MANHOLE PROPOSED PITTING GATE VALVE PROPOSED SEWER MANHOLE PROPOSED WATER HYDRANT PROPOSED WATER METER PROPOSED SEWER CLEANOUT N/F RODNER P. & MAZIE P HOLLLOMAN DB 1561 PG 305 P8 29 PG 335 383017102255 7fNIC• D Zn • • 4FH • lluIlgg� ARCZ�� _a. taploo SEAL 20106\\ ' 4010 let h • NOTES: 1-2" BLOW —OFF ASSEMBLY 1-8" GATE VALVE 1-8" CROSS 1 8"x6" REDUCER 1-8 GATE VALVE 1-6" GATE VALVE MAINTENANCEEASEMENT + + + + + + + + + + + + + N/F JONATHAN 8. WALSTON JENNIFER L. WALSTON DB 2843 PG 991 P8 39.PG 218 373905108577 7nhll• P.In ALL SEWER 8'0 SHALL BE PVC SDR-35 FOR DEPTHS UP TO 8' (SDR 26 FOR DEPTHS 8' TO 18') AND SHALL CONFORM TO ASTM D3034 OR UNLESS OTHERWISE SPECIFIED. DROP MANHOLES & MANHOLES OVER FIFTEEN FEET (15') DEEP (TOP RIM TO LOWEST POINT) SHALL BE 5'-0" IN DIAMETER. DROP MANHOLES SHALL BE USED WHERE THE INLET PIPE ELEVATION IS TWO FEET (2') OR MORE ABOVE BARTLETT ENGINEERING & SURVEYING, PC 1906 NASH STREET NORTH WILSON, N.C. 27893-1726 License No. C-1551 1-8" TEE W/ BLOCKING 2-8 GATE VALVE + + + + + + + + + + + + + + + + + + + + + + + ++ + + + + + + + + + + + + + + + + + + + N. + + + + + + + + + +\ + + + + + + + + + + 1 \ + + 1. + + + + + +•• + + + +\•, + + + + +\ + + + + + + + +•\ + + + + +•. + + + +\•, + + + + + + .� + + + + + + +\ + + + + + + +\ + + + + + + +'\ + + + + + + + '\ + + + + + + + + + + + + + +\•. + + + + + + +\. +\ FIRE HYDRANT N/F PAUL D. WHITLEY, JR. et al DB 972 PG 254 383013139352U ZONE: A-1 (FARM LAND/RESIDENTIAL USAGE) SHADY C 46' FIRE HYDRANT + + + + + + + + + + + + + + + + Sp+ + + + + + + + + + + + 4R0:f + + + + + + + + + + -TAR.p*t'1C+4T0,N + + + + + + + + + + 44 SL p-E.t + + + + .1. + + + + " + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + } + + ccJ ST ROAD THE LOWEST INVERT OF THE MANHOLE. ALL WATER 81.0 PVC AWWA C900 MAIN UNLESS OTHERWISE SPECIFIED. 6'10 DIP HYDRANT LEGS. ALL WORK TO BE IN ACCORDANCE WITH THE CITY OF ROCKY MOUNT STANDARDS AND SPECIFICATIONS. CONTRACTOR RESPONSIBLE FOR COMPLYING WITH ALL www.bartlett.us.com OVERALL UTILITY PLAN W/ BLOCKING 1-8" GATE VALVE 1-6" GATE VALVE 1-8" TEE W/ BLOCKING 2-8" GATE VALVE FIRE HYDRANT FIRE HYDRANT • im NW REQUIREMENTS/CONDITIONS OF ALL ENCROACHMENTS & PERMITS INCLUDING PROVIDING BONDS/INSURANCE IF REQUIRED. CONTRACTOR IS RESPONSIBLE FOR COORDINATING REQUIRED INSPECTIONS BY NCDOT AND/OR WITH UTILITIES SHOWN ON PLANS ARE LOCATED APPROXIMATELY. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION OF W/ BLOCKING 2-8 GATE VALVE FIRE HYDRANT FIRE HYDRANT ALL EXISTING UTILITIES AND SERVICES WHETHER SHOWN ON PLANS OR NOT. CALL ULOCO AT 1-800-632-4949. CONTRACTOR TO BE RESPONSIBLE FOR REMOVAL AND REPLACEMENT OF THESE FACILITIES IF DAMAGED. SEE SEDIMENTATION & EROSION CONTROL PLANS FOR DETAILED MEASURES. OLDE MILL STREAM (PHASE 2) CITY OF ROCKY MOUNT, NC 4- • 5 SWF WPM 27113-8 6 5 4 3 2 10 11 32 12 8" DIP INSIDE 80 LF 16"0 STEEL CASING • 13 75 011/47 nm CLin 1 25 • 24 18 16 • 49 50 60 11/4\ 59 58 • Certification by the Department of Development Services that this construction plat was approved by the city planning board on day of 20 Director of Development Services Certification by the City Engineering Department that this construction plat and required Improvement drawings meet the appropriate city standards. Director of Engineering DATE: AUGUST 2020 SCALE(VERT): REVISIONS: CRM 1ST REVIEW COMMENTS 10/13/2020 N/A PROJECT: 20-042 CLIENT CODE: RHC CADFILE: 20042CP7 FIELD BOOK: DRAWN BY: RF SURVEY BY: KP, JB ROCKY MOUNT TWNSP NASH COUNTY NORTH CAROLINA PIN # SHEET CP7 0 a. ea STRUCTURE TABLE STRUCTURE NAME DESCRIPTION TOP ELEV. INVERT IN INVERT OUT Al 36"x36" OUTLET STRUCTURE 123.75 121.00 A2 CATCH BASIN 127.00 121.16 121.16 A3 127.00 121.26 121.90 121.26 CATCH BASIN A4 CATCH BASIN 127.42 121.72 121.72 A5 CATCH BASIN (DOUBLE) 127 49 123.10 123.36 123.10 A6 CATCH BASIN 127.49 123.50 A7 CATCH BASIN 127.76 123.72 123.47 A8 CATCH BASIN 128.40 124.35 124.35 A9 128.00 124.47 DROP INLET A10 CATCH BASIN 127.57 122.10 122.10 A11 CATCH BASIN 127.57 122.22 122.22 Al2 CATCH BASIN 127.87 123.02 124.31 123.02 A13 CATCH BASIN 128.37 124.43 A14 CATCH BASIN 129.80 125.02 125.75 124.52 A15 CATCH BASIN 129.80 125.87 A16 CATCH BASIN 131.20 126.38 127.27 127.15 126.38 A17 CATCH BASIN 131.20 127.27 A18 CATCH BASIN 131.69 128.16 127.96 A19 CATCH BASIN 131.69 128.28 A20 CATCH BASIN 132.00 127.19 127.19 A21 CATCH BASIN 133.10 128.83 128.78 128.28 A22 CATCH BASIN 133.10 128.91 A23 CATCH BASIN 133.70 129.43 129.43 A24 CATCH BASIN 134.30 130.03 130.03 A25 CATCH BASIN 134.94 130.67 130.90 130.67 A26 CATCH BASIN 134.94 131.02 A27 CATCH BASIN 135.52 131.29 131.29 A28 CATCH BASIN 136.52 132.58 132.48 132.33 A29 CATCH BASIN 136.52 132.61 A30 CATCH BASIN 137.57 133.34 133.34 A31 CATCH BASIN 137.57 133.66 133.46 A32 CATCH BASIN 138.85 134.94 81 36"x36" OUTLET STRUCTURE 123.71 121.50 BARTLETi" ENGINEERING & SURVEYING, PC 1906 NASH STREET NORTH WILSON, N.C. 27893-1726 License No. C-1551 TELE: (252) 399-0704 FAX: (252) 399-0804 www.bartlett.us.com STRUCTURE TABLE STRUCTURE NAME DESCRIPTION TOP ELEV, INVERT IN INVERT OUT B2 DROP INLET 128.93 120.83 120.83 83 CATCH BASIN 130.21 121.47 121.47 84 CATCH BASIN 130.22 121.60 126.43 121.60 85 CATCH BASIN 134.49 130.64 130.44 86 CATCH BASIN 136.17 132.27 B7 CATCH BASIN 127.49 122.67 122.17 122.17 88 DROP INLET 131.44 127.70 127.20 89 CATCH BASIN 138.27 134.24 133.99 610 CATCH BASIN 138.27 134.36 811 CATCH BASIN (DOUBLE) 126 96 123.03 123.76 122.53 812 CATCH BASIN 126.96 123.90 B13 CATCH BASIN 127.59 123.71 123.71 B14 CATCH BASIN 124.10 124.10 127.99 615 CATCH BASIN 128.34 124.46 124.46 B16 CATCH BASIN 128.99 125.59 125 09 817 CATCH BASIN 129.60 125'79 126.33 125.79 B18 CATCH BASIN 129.60 126.45 819 CATCH BASIN . 131.02 127.11 126.86 820 CATCH BASIN 132.03 128.11 621 CATCH BASIN (DOUBLE) 127.63 123.29 122.79 822 CATCH BASIN (DOUBLE) 127.63 123.54 124.27 123.42 B23 CATCH BASIN 129.01 125,10 125.10 B24 CATCH BASIN 130.23 126.32 825 CATCH BASIN 129.09 123.74 123.74 B26 DROP INLET 129.82 125.53 126.57 125.53 827 DROP INLET 130.78 127.53 828 CATCH BASIN 133.08 127.52 127.32 B29 132.70 127.91 127.71 830 CATCH BASIN (DOUBLE) 132.70 128.54 128.04 831 CATCH BASIN 133.89 129.99 129.96 B32 CATCH BASIN 136.86 132.96 132.74 B33 CATCH BASIN 138.08 133.99 133.79 834 CATCH BASIN 138.08 134.13 STORMWATER STRUCTURE & PIPE TABLE PIPE TABLE UPSTREAM STRUCTURE DOWNSTREAM STRUCURE PIPE SIZE (INCHES) LENGTH (FEET) SLOPE MATERIAL UPPER INVERT LOWER INVERT Al I LA1 24 46.0 1.000% RCP 121.00 120.54 A2 LA2 42 43.2 0.373% RCP 121.16 121.00 A3 A2 LA3 42 27.5 RCP IV 121.26 121.16 0.350% A4 A3 LA4 24 77.2 0.600% RCP 121.72 121.26 A5 A4 LA5 24 229.0 0.601% RCP 123.10 121.72 A6 A5 LA6 15 27.5 0.500% RCP 123.50 123.36 A7 A5 LA7 18 73.9 0.503% RCP 123.47 123.10 A8 A7 LA8 15 125.0 0.501% RCP 124.35 123.72 A9 A8 LA9 15 24.9 0.512% RCP 124.47 124.35 A10 A3 LA10 30 40.9 0.473% RCP 122.10 121.90 All A10 LA11 30 24.5 0.500% RCP 122.22 122.10 Al2 All LA12 30 80.0 1.000% RCP 123,02 122.22 A13 Al2 LA13 15 24.5 0.500% RCP 124.43 124.31 A14 Al2 LA14 30 142.6 1.050% RCP 124.52 123.02 A15 A14 LA15 15 24.5 0.500% RCP 125.87 125.75 A16 A14 LA16 24 136.1 1.000% RCP 126.38 125.02 A17 A16 LA17 15 24.5 0.500% RCP 127.27 127.15 A18 A16 LA18 15 40.0 1.727% RCP 127.96 127.27 A19 A18 LA19 15 24.5 0.500% RCP 128.28 128.16 A20 A16 LA20 24 81.0 RCP 127.19 126.38 1.000% A21 A20 LA21 24 109.7 1.000% RCP 128.28 127.19 A22 A21 LA22 18 24.5 0.500% RCP 128.91 128.78 A23 A21 LA23 18 60.0 1.000% RCP 129.43 128.83 A24 A23 LA24 18 60.4 1.000% RCP 130.03 129.43 A25 A24 LA25 18 64.4 1.000% RCP 130.67 130.03 A26 A25 LA26 15 24.5 0.500% RCP 131.02 130.90 A27 A25 LA27 18 55.7 1.110% RCP 131.29 130.67 A28 A27 LA28 18 94.6 1.100% RCP 132.33 131.29 A29 A28 LA29 15 24.5 0.500% RCP 132.61 132.48 A30 A28 LA30 15 100.5 0.751% RCP 133.34 132.58 A31 A30 LA31 15 24.5 0.500% RCP 133.46 133.34 A32 A31 LA32 15 128.0 1.000% RCP 134.94 133.66 B1 L81 18 38.0 1.000% RCP 121.50 121.12 82 LB2 42 32.2 0.400% RCP 120.83 120.70 83 B2 LB3 36 128.0 0.500% RCP 121.47 120.83 OLDE MILL STREAM (PHASE 2) CITY OF ROCKY MOUNT, NC - PIPE TABLE UPSTREAM STRUCTURE DOWNSTREAM STRUCURE PIPE SIZE (INCHES) LENGTH (FEET) SLOPE MATERIAL UPPER INVERT LOWER INVERT 84 B3 L84 36 27.5 0.500% RCP IV 121.60 121.47 85 84 LB5 15 154.3 2.600% RCP 130.44 126.43 86 B5 L86 15 112.4 1.447% RCP 132.27 130.64 87 84 LB7 36 114.3 0.500% RCP IV 122.17 121.60 B8 B7 LB8 24 149.8 3.022% RCP 127.20 122.67 89 B8 LB9 18 175.1 3.592% RCP 133.99 127.70 B10 B9 L810 15 24.5 0.500% RCP 134.36 134.24 B11 87 LB11 30 71.5 0.500% RCP IV 122.53 122.17 B12 B11 LB12 15 27.5 0.500% RCP IV 123.90 123.76 B13 B11 L813 24 136.2 RCP IV 123.71 123.03 0.500% 614 B13 L814 24 77.4 0.494% RCP IV 124.10 123.71 615 814 LB15 24 70.6 0.513% RCP IV 124.46 124.10 816 515 LB16 24 127.9 0.493% RCP IV 125.09 124.46 617 B16 L817 18 40.7 0.500% RCP IV 125 79 125.59 818 817 L818 15 24.5 0.500% RCP IV 126.45 126.33 B19 817 LB19 18 125.2 0.852% RCP IV 126.86 125 79 B20 519 LB20 15 104.9 0.952% RCP 128.11 127.11 B21 LB21 30 169.2 0.500% RCP 122.79 121.95 822 B21 L822 24 24.5 0.500% RCP IV 123.42 123.29 B23 822 L823 15 165.9 0.500% RCP 125.10 124.27 824 823 LB24 15 122.1 RCP 126.32 125.10 1.000% 825 B22 L825 24 18.6 1.100% RCP IV 123.74 123.54 B26 825 L826 • 24 149.1 1.200% RCP 125.53 123.74 827 826 LB27 15 96.0 RCP 127.53 126.57 1.000% B28 826 LB28 24 134.1 1.336% RCP 127.32 125.53 829 B28 LB29 24 37.4 0.500% RCP 127.71 127.52 B30 829 LB30 24 24.5 0.520% RCP 128.04 127.91 831 B30 L631 15 141.8 1.000% RCP 129.96 128.54 B32 831 LB32 15 239.6 1.150% 132.74 129.99 RCP B33 832 LB33 15 39.9 2.095% RCP 133.79 132.96 834 833 LB34 15 0.500% RCP 134.13 133.99 27.5 LC1 30 60.0 0.500% RCP 122.60 122.30 LC2 30 60.0 0.500% RCP 122.60 122.30 LC3 30 60.0 0.500% RCP 122.60 122.30 • Certification by the Department of Development Services that this construction plat was approved by the city planning board on day of 20 Director of Development Services Certification by the City Engineering Department that this construction plat and required Improvement drawings meet the appropriate city standards. Director of Engineering DATE. AUGUST 2020 SCALE(HORZ): SCALE(VERT): REVISIONS: N/A N/A PROJECT: 20-042 CLIENT CODE: RHC CADFILE: 20042CP7 FIELD BOOK: DRAWN BY: RF SURVEY BY: KP, JB ROCKY MOUNT TWNSP NASH COUNTY NORTH CAROLINA PIN # ZONE: R-6 & 0-1 SHEET CP8 NOTES: . FOR HYDRANT INSTALLATION ON EXISTING MAIN, USE TAPPING SLEEVE AND VALVE PER STANDARD N 5.12 2. RESTRAINING GLANDS MAY BE USED IN LIEU OF THREADED RODS IF APPROVED BY ENGINEER. PROPERTY LINE BURY UN 10 CP (MIN) CRUSHED. STONE CONCRETE THRUST BLOCKING CONCRETE SETTING SLAB I'-3' x I'-3' 4' THICK :'. TIRE HYDRANT, PUMPER NOZZLE TO FACE STREET 5' STOR2 NOZZLE z v - STABLE. WELL -COMPACTED.. SUBGRADE le t' C I'u¢~,V.L`, L11S (i ROCKY I MOUNT 1 dub DEPARTMENT OF ENGINEERING HYDRANT INSTALLATION (SHEET I OF 2) SIDEWA /, COMPACTED BACKFILL (TAMPED IN 6' LIFTS) VALVE BOX PER STANDARD // 5.9 G' BRANCH PIPE (DUCTILE IRON OR APPROVED MATERIAL) PAVEMENT AWWA V GATE VALVEE VA WITH / MJ CONNECTIONS. • /. 3.i BRIDLE ROD AND TIE BOLT - -' EACH SIDE WITH TWO COATS CONCRETE OP BITUMINOUS COATING THRUST BLOCK.. DATE: NOVEMBER 2019 STANDARD 11 5.1 APPROVED: sneer N I OF 2 VISION; HYDRANT GENERAL CONSTRUCTION NOTES FIRE HYDRANT: HYDRANT SHALL BE AWWA C502, DRY BARRELL. DRY BONNET, THREE-WAY HYDRANT WITH 3' G' MINIMUM. BURY. 4 1/2' MIN. MAIN VALVE OPENING, 4 I/2' PUMPER NOZZLE, TWO EACH 2.1/2' HEM NOZZLES, REPLACEABLE BRONZE NOZZLES WITH NATIONAL STANDARD THREADS, BREAK -AWAY TRAFFIC FEATURE, AND BRONZE ON BRONZE SEAT RINGS. HYDRANT SHALL HAVE PENTAGON SHAPED (5 SIDED) OPERATING NUT AND SHALL OPEN TURNING LEFT (COUNTER -CLOCKWISE.) MANUFACTURERS PAINT: OIL/GREASE: RESTRAINT: Irrh-'-'° ROCKY 4 t MO UNT .u�I DEPARTMENT OF ENGINEERING AMERICAN DARLING MK-73-1 MUELLER CENTURION A421 KENNEDY GUARDIAN WATEROUS TREND 100 CHAINS SHALL BE REMOVED, AND HYDRANT SHALL BE PAINTED WITH RUSTOLEUM 11964 FEDERAL SAFETY RED. NOZZLE CAPS AND BONNET SHALL ALSO RECEIVE A COAT OF ALERT SERIES 1440 SILVER WHITE AS MANUFACTURED BY FERRO, INC. OR APPROVED EQUAL. HYDRANT SHALL BE OILED OR GREASED A5 RECOMMENDED BY MANUFACTURER AFTER INSTALLATION. ALL INSTALLATIONS SHALL HAVE CLASS A CONCRETE BLOCKING PLACED BEHIND BOTH TEE AND HYDRANT. EN LIEU OF THREADED BRIDLE RODS. APPROVED GRIP RING OR LOCKING FLANGE CONNECTIONS MAY BE USED. BOTH GRIP RINGS AND LOCKING FLANGES SHALL BE U.L. LISTED AND F.M. APPROVED WITH A RATED WORKING PRESSURE OF NOT 12.55 THAN 350 P51 WITH A MIN. SAFETY FACTOR OF 2:1. LOCKING FLANGE CONNECTIONS SHALL ONLY BE PERMITTED WHERE PROPER PLACEMENT AND GRADE ADJUSTMENT CAN BE PROVIDED, HYDRANT INSTALLATION (SHEET 2 OF 2) DATE: NOVEMBER 2019.. APPROVED: STANDARD N: 5.2 5HCCTM2OF2 REVISION: iA �- HYDRANT ASSEMBLY PER STD. NO. 5.1 I6I I L11 L TLLJ I L°N11=' i DIRECT ROD VALVE TO TEE PER STD. NO. 5.13 NOTE: ALL DEAD END MAINS " & LARGER SHALL HAVE A FIRE HYDRANT AT ITS TERMINUS. IF LINE TER:/:NATION IS TEMPORARY. FIRE HYDRANT NAY DE' RELOCATED WHEN LINE IS EXTENDED TO MEET SPACING REDUIREMENTS. A VALVE SHALL DE PLACED IN PLACE OF THE HYDRANT TEE FOR TESTING OF THE EXTENSION. STANDARD VALVE BOX PER STD NO. 59 THRUST COLLAR PER STD. NO. 5.19 ONE JOINT OF MECHANICAL JOINT DUCTILE IRON PIPE WITH PLUG VALVE SIZED FOR FUTURE I4AIN EXTENSION TEMPERARY LINE TERMINUS (6" & LARGER MAINS) pin (DALE RE VISIONS ( CITY OF ROCKY MOUNT DEPT OF ENGINEERING APPROVED STD. NO. 5.3 DAIE REVISION 06-25-09 - BARTLETT ENGINEERING & SURVEYING, PC 1906 NASH STREET NORTH WILSON, N.C. 27893-1726 License No. C-1551 NOTE' MECHANICAL JOINT TAPPING SLEEVES SHALL HAVE A WORKING PRESSURE OF NOT LESS THAN 200 PSI HAVING RIGID CAST DUCTILE IRON BODY SUITABLE FOR INSTALLATION ON BOTH DUCTILE IRON PIPE AND CAST IRON PIPE WITH OUTLET FLANGES PER ANSI/AWWA C110/A21.10 SPECIFICATIONS, THE VALVE SHALL BE MANUFACTURED TO AWWA SPECIFICATION CLASS 350, OPEN LEFT, E> NOTES 1. CONCRETE SHALL NOT CONTACT BOLTS OR ENDS OF MECHANICAL JOINT FITTINGS. 2, SEE STANDARD THRUST BLOCK TABLES, FOR AREA OF CONCRETE REQUIRED. 3, 2500 PSI CONCRETE CLASS B REQUIRE➢. 4. TAPPING SLEEVE & VALVE SHALL BE BOLTED IN PLACE & PRESSURE TESTED PRIOR TO TAPPING OF EXISTING MAIN, SOLID CONCRETE OR BRICK BLOCKING SHALL BE USED AS FOOTING FOR DUCTILE IRON PIPE E> TAPPING SLEEVE & VALVE N11 DATE REVISIONS DFCCRIPTInN CITY OF ROCKY MOUNT DEPT. OF ENGINEERING APPROVED STD.NO. 5.12 DATE 04-04-06 REVISION WO IA GU RIGHT Dr WAY VARIES 3/4. OR 1' HOPE SDR-9 200 PSI SERVICE PIPE W/TRACER WIRE, DR PER TYPE ASTNOD-OO. SERviCC CORP. STOP BY DUELLER NO. H-15175 OR IIAYES SDnO DIRECT TAP ON 4' DIAMETER OR ��- LARGER DIP OR CIP MAINS ONLY. ALL OTIICR TAPS SHALL DC BADE VFTII SOLID BRASS. TWO OR THREE PIECE SERVICE SADDLES COMPLYING WITH AWVA C(100 Ilc LITTER FROM CITY ONLY CURB STOP-1NCL. III METER BOX ASSEMDLY n PRO%. I CU F1. CRUSHED NOTES: STONE AROUND BASE I. METER BOXES ARE TO DE PLACED IN TURFED AREAS. CASTINGS SHALL NUT BE EXPOSED TO TRAFFIC LOADINGS. 2. ALL METERS SHALL READ IN CUBIC FEET. 3. I1ETERS SHALL HE PURCHASED FROM CITY OF ROCKY MOUNT ONLY. 4. ALL CORPORATION STOPS, CURB STOPS, END CONNECTORS, ETC. SHALL HE SOLID BRASS MANUFACTURED IN ACCORDANCE WITH AWWA CND. 5. STANDING IN STREET PACING HOUSE, WATER METERS ARE 10 BE LOCATED 3' RIGFIT OF SEWER STACK. 6. 14ETER DOx SHALL BE FORD CRESCENT BOX (MODEL EMIT-233 FOR 5/8' X 3/4' OR CDUI-444 FOR 1') AS MANUFACTURED BY FORD METER BOX CO. OR AN APPROVED EDUAL MODEL. 7. INSTALL DETECTABLE SOLID 10 GUAGE TRACER WIRE. USE TIE WRAPS AT 4' NTERVALS TO SECURE TRACER WIRE -TO PIPE. 8. STUB OUT A M1N114UN or 12' OF TRACER WIRE IN EACH METER BOX. IP/FLARED CONVECTOR NU. 15425 OR IP/COMP. CONVECTOR NU 15428 OR APPRUVED EQUAL FINISHED GRADE METER D -.JURASS CLAMPING DCVICE- 1111CLUDED IN NCTCR MU ASSEMBLY. DRAIN HOLES 5/8" x 3/4" 1" WATER SERVICE REVISIONS Nn PATF RF Rf.PIP finN PROPERTY LINE DORY L➢K�-Ii 10 CU. Ft, Him. CRUSHED STONE: 1.0 1a CONC. THRUST BUMMING- CONC. SETTING SLAB I'-3' X 1'••3- X 4' THICK CITY CE ROCKY IMCUNT DEPT OF ENGINEERING APPROVED DATE 6-30-09 STD. NO, 5.5 REVISION FIRE HYDRANT, PUM 70 FACE STREET SIOEWAt,, wozzig NOTE. FOR HYDRANT INSTALLATION UN EX! TING MAIN. uSE TAPPING SLEEVE AND VALVE PER STD. No. 5.12 VALVE BOX PER STD. NO. 59-\ • • COMPACTED BACKFIL (TAMPED IN 6' LIFT 6' DIP BRANCH PIPE E_Q IT ll-�'-m u -urQ. =IRJIIJYL9i61D1-ALIT 3/4' BRIDLE ROD t. TIE BOLT EACH SIDE V/TVO COATS CF BITUMINOUS COATING STABLE, WELL - COMPACTED SUBGRADE --- 6' JOINT MIN PAVED[: 6' AWWA C509 GATE. VALVE W/ III CONNECTIONS • 4 THRUST COLLAR PER STD. HO. 5.19 L6' MIN. a PERMANENT LINE. TERMINUS ID IRATE REVISIONS DF SCRIPT MN TELE: (252) 399-0704 FAX: (252) 399-0804 www.bartlett.us.com CITY OF ROCKY M:UNT DEPT OF ENGINEERING DETAILS APPROVED STD. NO. 5.3a DA1E 06-25-09 REVISION CONSTRUCTION NOTES: FOR INSTALLATION, REFER TO MATERIAL AND CONSTRUCTION NOTES ON STD. DWG. 4.2, PRECAST CONCRETE MANHOLE NOTES PRE -CAST CONCRETE RING OR BRICK & MORTAR GRADE ADJUSTMENT (LIMIT - THREE COURSES OR 6' MAX.> SECTION A ---A STEPS PER STD, DWG. NO. 4.8 I6' G.C. EXIST. STABLE AND/OR WELL COMPACTED SUBGRADE C.I. FRAME & COVER PER STD. DWG. NO. 4.6 (OR 4,7 FOR WATERTIGHT) SECURED WITH MORTAR ECCENTRIC CONE RISER N. IX N. GRADE 6' x 6' MIN. EXTENDED FOOTING WHERE REQUIRED SET MANHOLE ON MIN. 6' N57 STONE PRECAST CONCRETE MANHOLE REVISIONS Nn DATE OFSCRIPTInN CITY OF ROCKY MOUNT DEPT. OF ENGINEERING APPROVED STD. NO. 4.1 DATE REVISION 04-10-99 NOTES: PRECAST CONCRETE MANHOLES SHALL MEET OR EXCEED THE REQUIREMENTS OF ASTM C 478. ALL SURFACES SHALL BE SMOOTH AND EVEN TEXTURED WITH A MINIMUM OF HONEYCOMB, FIN, AND OTHER IMPERFECTIONS. 2, JOINTS BETWEEN MANHOLE SECTIONS SHALL BE SEALED WATERTIGHT USING EITHER 0-RING GASKETS CONFORMING WITH ASTM C 443 OR BUTYL RESIN CONFORMING WITH AASHTO M-198. 3. HOLES FOR CONNECTION OF PIPE TO MANHOLE SHALL BE PRECAST OR CORED. DIAMETER OF HOLE SHALL NOT EXCEED OUTSIDE DIAMETER OR PIPE BY MORE THAN 3 INCHES. 4. CONNECTIONS OF PIPE TO MANHOLE SHALL BE MADE WATERTIGHT USING RESILIENT CONNECTORS CONFORMING TO ASTM C 923 OR NEOPRENE BOOTS EMBEDDED IN PRECAST BASE WITH STAINLESS STEEL COMPRESSION BANDS, 5, MANHOLE INVERTS SHALL BE INSTALLED USING BRICK AND MORTAR, OR MANHOLES MAY BE PRECAST, MONOLITHIC SECTIONS WITH FORMED INVERTS, 6, LIFT HOLES SHALL BE PLUGGED AND FILLED FLUSH WITH MORTAR. 7. ALL BRICK AND MORTAR SHALL RECIEVE A 1/2' MORTAR PARGE COAT ON INSIDE AND OUTSIDE, PRECAST CONCRETE MANHOLE NOTES NO DATE REVISIONS DESCRIPTION i 1 1 1 1 1 1=III-' 1 I -I I ECLIPSE 2000-B BLOW OFF HYDRANT (3' MIN, BURY) UNDISTURBED EARTH CONCRETE BLOCKING CITY OF ROCKY MOUNT DEPT. OF ENGINEERING 1 1 1 1 1 I-' 1 I -I "_ 6' MAX, ISTANDARD VALVE BOX PER STD. NO, 5,9 2' RED BRASS OR COPPER NIPPLE CRUSHED ROCK B E 1 U APPROVED STD. NO. 4.2 DATE 04-21-04 REVISION NOTES: BLOW -OFF HYDRANTS SHALL BE NO. 2000-B AS MANUFACTURED BY JOHN C. KUPFERLE FOUNDRY CO., ST. LOUIS, MD, OR AN APPROVED EQUAL. HYDRANTS SHALL BE NON -DRAINING TYPE MR PLACEMENT IN PAVEMENT. HYDRANTS SHALL DE COMPRESSION TYPE CLOSING WITH PRESSURE AND FURNISHED WITH 2' FIP INLET. HYDRANTS SHALL BE OPERATED BY USE OF A PORTABLE TOP STOCK COUPLING WITH THE HYDRANT AT OR NEAR THE GROUND LEVEL ALL WORKING PARTS INCLUDING THREAD PROTECTOR AND OPERATING ROD SHALL BE BRASS AND REMOVABLE FROM THE HYDRANT WITHOUT NEED FOR EXCAVATION, BRASS THREAD PROTECTOR SHALL HAVE A 2' SQUARE NUT. !MECHANICAL JOINT TAPPED PLUG THRUST COLLAR PER STD NO 520 SET IN MIDDLE OF FULL JOINT <18-20') ALTERNATE 2" BLOW OFF DETAIL J i bATF REVISIONS _DESCRIPTION CITY OF ROCKY MOUNT DEPT. OF ENGINEERING APPROVED DATE 02-19-03 OLDE MILL STREAM (PHASE 2) - CITY OF ROCKY MOUNT, NC STD. NO. 5.4A REVISION 2618" I N " CA po RAY IRON ASTM A48.84, CLASS 25 EINE COAT POWERCRON 690 .4.1,6 MIL TRICK, BLACK NOTES 1. LID TO BE MANUFACTURED BY FORD METER BOX COMPANY OR APPROVED EQUAL 3/4' & 1" WATER METER BOX COVER REVISIONS ND JIIATF DECCRIPT ION CITY ET ROCKY MOUNT DEPT OF ENGINEERING APPROVED EMEINE STD. NO. 5.5 A DATE 5-01-07 REVISION 501:1D. 12 GUAGE -. TRACER WIRE -- I I I I I -I IIII i t-I I -..--I I, i- 1- F 1-I IL " CHIT) Ij14iit 1tlLI:IIII III/IIi,ut I: H) I IIII.IJ i,ll USE OF TRAPS AT I INTERVALS. TO SECURE _,__- / SOLID 12 GUAGE'. \ TI, CER LIRE �' • TOR. PE / • NOTES: 1, INSTALL, DETECTABLE SOLID. 12. GUAGE TRACER WIRE AUOVE ALL NONMETALLIC LYATER PII'ES .INCLUDING. SERVICE CONNECTIONS:: SECURE; ALL WITS 1YITS TIE WRAPS. D. MAKE DETECTABLESOLID IR GUAGE TRACER WIRE: ACCESSIBLE; IN LYATER METER BOXES, VALVE UOXKS, OR .CASINOS, OR:: OUTSIDE THE. FOUNDATIONS' •OF BUILDINGS \MERE THE; PIPE: ENTERS TIER ' DUILGINU. G: STUD OUT A MINIMUM OR I.` OF TRACER WIRE ; IN EACII. VALVE 110X :AND METER BOX FOR: LOCATING PURPOSES.. 4. NO WIRE NUTS ALLOWED USE ONLY INLINE DRABS; BUTT CONNECTORS TO INSURE SOLID, SPLICES OF 'TRACER WIRES. G. INSPECTORS. SN.S`T VERIFY ALL CONNECTIONS AND POSITIVE TRACINII. SIGNAL FOR ALL MAINS AND .SERVICES, BEFORE CONDITIONAL AND FINAL ACCEPTANCE,. TRACER'' WIRE FOR UTILITY II`;1STAL;LATIGN'S 1 NO REVISIONS DATF DCRCRIPa'IM' CITY Zr R . CIKY MOUNT DEPT. OF ENGINEERING APPROVED S(ll. NO, 1.17 PATE •09-d3-0•8: RE MIEN STREET C/L MONOLITHIC'V' W/ a BEND FITTING 1 I SEWER MAIN h' PIPE OR b BEND VARIES HAND SHAPED. STABLE SUBGRADE EXCAVATED TO CONFORM TO PIPE AND BELLS OR HAND PLACED CLEAN, WASHED STONE (2'3' OF NCDOT HG7) CRM POINT -' OF SERVICE : 12' MIN. 184 MAX. MONOLITHIC !VW/ . BEND FITTING , DEPTH VARIES 4' - G' DEPTH OO ROW RECOMMENDED (SEE NOTE 2) IF GREATER THAN 6' SEE IN5ET'A' 1' 4° CASTIIRORON00R Ire OR 1' STUB W/PLUGDUCII 11 4' PVC(5DR 23.5 OR 5DR 2G) INSET A NOTES I. MIN. GRADE POR 4 SEWER SERVICE SHALL BE I.0 %(j* PER FT.) RECOMMENDED MIN. GRADE SHALL BE 2.0 %. 2. DEPTH OF SERVICE AT PROPERTY LINE MUST BE SUFFICIENT TO PROVIDE AT LEAST MIN. GRADE TO BUSINESS OR DWELLING AND 12' MIN. COVER OVER SERVICE. 3. FOR NEW SUBDIVISIONS, CLEANOUT STACKS SHALL BE PLACED 3' TO THE LEFT OF THE WATER METER WHEN LOOKING FROM THE ROADWAY OR SEWER MAIN. 4. ALL SERVICES SHALL HAVE A CLEANOUT PLACED AT THE EASEMENT OR RIGHT OF WAY UNe. ALL CLEANOUTS SHALL BE CAST IRON WITH BRASS FLOGS. CAST IRON DOUBLE -HUB CONNECTORS (30' MIN.) MAY BE USED TO TRANSITION FROM PC SERVICE PIPE, 5. ALL PC FITTINGS SHALL BE OF HEAVY WALL CONSTRUCTION (I 15 P51 MIN. PIPE STIFFNESS.) G. ALL PIPE WITHIN RIGHTS OF WAY SHALL HAVE PUSH -ON JOINTS WITH EIASTOMERIC GASKET SEALS. 7. SIX INCH AND LARGER SERVICES SHALL CONNECT AT MANHOLES. fi I ROCKY ,nrrr4or MOUNT d� DEPARTMENT OF ENGINEERING 12' MIN. i B" MAX. STANDARD 4" SERVICE LATERAL CRM POINT OF SERVICE RAW 3' MIN. 4' CAST IRON SOIL PIPE OR 4' DUCTILE IRON OR 4' PVC (5DR 23.5 OR SOR 2G) GLUE CAP FOR AIR TESTING (10 REMAIN) CO 45° BEND. TOR PVC LATERALS, FITTINGS, FOR DI LATERALS, UTILIZE MJ PITTING WITH TRANSITION GASKET OR PUSH -ON t DI x PVC PITTING. • DATE: APRIL 2018 APPROVED: DATE. AUGUST 2020 SCALE(HORZ): REV SIONS: CRM 1ST REVIEW COMMENTS 10/13/2020 Certification by the Department of Development Services that this construction plat was approved by the city planning board on day of 20- Director of Development Services Certification by the City Engineering Department that thls construction plat and required improvement drawings meet the appropriate city standards. Director of Engineering PROJECT: 20-042 CLIENT CODE: RHC FIELD BOOK: DRAWN BY: RF SURVEY BY: KP, JB ROCKY MOUNT TWNSP NASH COUNTY PIN # SHEET CP9 0 a. 0 40* 0 0 0 0 CONSTRUCTION NOTES: ALL IMPROVEMENTS SHALL CONFORM TO THE CITY OF ROCKY MOUNT'S LAND DEVELOPMENT CODE AND THE MANUAL OF SPECIFICATIONS AND DETAILS. PROJECT PLANS AND BENCHMARKS ARE BASED ON NAVD 88 VERTICAL DATUM AT NAD 83 HORIZONTAL DATUM TO THE ACCURACY SPECIFIED IN 21 NCAC 56.1603 (CLASSIFICATION OF BOUNDARY SURVEYS), PARAGRAPH (1) LOCAL CONTROL NETWORK SURVEYS (CLASS AA) AND 21 NCAC 56.1605 CLASSIFICATION OF VERTICAL CONTROL SURVEYS PHARAGRAPH (1) URBAN AND SUBURBAN VERTICAL CONTROL SURVEYS (CLASS A). WHERE THE CORNERS ARE TIED USING GPS SURVEYING METHODS, THE PROCEDURES USED SHALL CONFORM TO 21 NCAC56.1603 GLOBAL POSITIONING SYSTEM SURVEYS. THE POSITION S OF BOTH THE REFERENCED CORNERS AND THE MONUMENTS USED SHALL BE SHOWN IN X (EASTING) AND Y (NORTHING) AND Z (ELEVATION). THE CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING THAT A MINIMUM OF TWO (2) PROJECT CONTROL MONUMENTS AS SPECIFIED HEREINAFTER ARE INSTALLED BY A REGISTERED PROFESSIONAL LAND SURVEYOR AND SHALL BE FIELD LOCATED BY THE ENGINEER. ALL MONUMENTS SHALL BE CONSTRUCTED OF CONCRETE AND BE AT LEAST FOUR (4) INCHES IN DIAMETER OR SQUARE, NOT LESS THAN THREE (3) FEET IN LENGTH AND INSTALLED WITH THE TOP FLUSH WITH THE FINISHED GROUND. EACH MONUMENT SHALL HAVE A STANDARD METAL PLATE IMBEDDED IN ITS TOP OF NON CORRODIBLE MATERIAL MARKED PLAINLY WITH THE BENCH POINT, THE MONUMENT NUMBER AND IDENTIFIED AS A PART OF THE CITY OF ROCKY MOUNT GEODETIC CONTROL SYSTEM. THE PROJECT CONTROL MONUMENTS SHALL BE LOCATED ON THE STREET RIGHT OF WAY TO FACILITATE CONSTRUCTION CONTROL BUT MAY BE INCORPORATED AS A PROPERTY CONTROL CORNER. IN ALL CASES THE CONTRACTOR SHALL PROTECT PROJECT CONTROL MONUMENT(S) FROM DISRUPTION DUE TO CONSTRUCTION OPERATIONS. THE NORTH CAROLINA GEODETIC SURVEY CAN BE REACHED ON THE WEB AT www.ncgs.state,nc.us. DISTURBED AREA IS IN EXCESS OF 1 ACRE AND FORMAL SEDIMENTATION & EROSION CONTROL PLAN APPROVAL WAS REQUIRED AS A CONDITION OF CONSTRUCTION PLAN APPROVAL. A COPY OF THE APPROVED EROSION CONTROL PLAN MUST BE KEPT ON SITE AT ALL TIMES. THE APPROVED SEDIMENTATION & EROSION CONTROL PLAN SHOULD BE REGARDED AS MINIMUM REQUIREMENTS; ADDITIONAL MEASURES SHALL BE PUT IN PLACE AS NEEDED TO INSURE THAT NO SEDIMENT IS RELEASED FROM THE SITE. OVERALL IMPERVIOUS AREA IS GREATER THAN 15% OF THE SITE OR THE INCREASE IN PEAK DISCHARGE FROM THE SITE IS MORE THAN 10% THEREFORE A STORMWATER DETENTION SYSTEM IS REQUIRED. DETENTION AND NUTRIENT MANAGEMENT REQUIREMENTS MUST BE MET WITH ANY FUTURE DEVELOPMENT, OR AT SUCH TIME AS ANY OF THE THRESHOLDS FOR THOSE REQUIREMENTS ARE REACHED PER THE LAND DEVELOPMENT CODE. WATER AND SEWER PERMIT APPLICATIONS HAVE BEEN APPROVED BY THE NCDEQ. PERMIT NUMBERS ARE AS FOLLOWS: WATER PERMIT NUMBER: SEWER PERMIT NUMBER: NCDEQ WATER AND SEWER PERMITS MUST BE RECEIVED BY THE CITY OF ROCKY MOUNT PRIOR TO CONSTRUCTING WATER AND SEWER MAINS. PAYMENT OF WATER AND SEWER SERVICES FEES MAY BE DUE PRIOR SETTING OF TAPS OR METERS, CONTACT NEGRETE SILVER AT 972-1127 TO DETERMINE APPUCABLE FEE(S). NCDOT AND/OR CITY DRIVEWAY PERMIT IS REQUIRED FOLLOWING CONSTRUCTION PLAN APPROVAL. PAVEMENT SECTION IS REPRESENTATIVE OF A ROADWAY GEOMETRY ONLY. A GEOTECHNICAL REPORT AND PAVEMENT DESIGN SEALED BY A REGISTERED PROFESSIONAL ENGINEER MUST BE APPROVED BY THE CITY ENGINEER PRIOR TO THE PLACEMENT OF ANY ROADWAY IMPROVEMENTS. ALL GEOTECHNICAL TESTING PROCEDURES AND REPORTS SHALL BE IN ACCORDANCE WITH CITY STANDARDS. SUB -GRADE SOIL CONDITION MUST BE EVALUATED AND CERTIFIED, INCLUDING IN -PLACE DENSITY, BY A GEOTECHNICAL ENGINEER FOR CONFORMANCE WITH PAVEMENT DESIGN CONDITIONS AND A PROOF -ROLL MUST BE WITHNESSED AND APPROVED BY CITY ENGINEERING DEPARTMENT REPRESENTATIVE PRIOR TO PLACEMENT OF STONE BASE. SITE LIES IN FLOOD ZONE X WITH PORTIONS WITHIN THE 100-YEAR FLOODPLAIN AND FLOODWAY, PER FEMA FIRM # 3720383000K DATED JUNE 18, 2013. BASE FLOOD (100-YEAR) ELEVATIONS ARE 118 FT NEAR POND#1 AND 121 NEAR POND#2. COPIES OF ALL PERMITS AND APPROVED PLANS SHALL BE PREPARED IN ACCORDANCE WIN CITY STANDARDS AND PROVIDED PRIOR TO FINAL PLAT APPROVAL. THE PROJECT ENGINEER IS RESPONSIBLE FOR RESOLVING ANY DESCREPANCY BETWEEN THE FIELD CONDITIONS AND PLAN ELEVATIONS AND IMPROVEMENTS. FOR THE INSTALLATION OF ELECTRICAL SERVICES, LOCATION OF PAD -MOUNTED TRANSFORMER IF NEEDED AND TO COORDINATE ELECTRICAL TEMPORARY SERVICE, CONTACT PUBLIC UTILITIES AT (252) 972-1273. FOR THE INSTALLATION OF GAS SERVICES, CONTACT ROCKY MOUNT ENERGY RESOURCES AT (252)467-4807 OR (252)467-4829. ANY RELOCATION OF EXISTING UTILITIES WILL BE AT THE COST OF THE DEVELOPER/OWNER. THE CITY WILL NOT ACCEPT RESPONSIBILITY FOR DAMAGES TO CURB AND GUTTER OR STREET IMPROVEMENTS IF INSTALLED PRIOR TO UNDERGROUND SERVICES, NOR WILL THE CITY ABSORB THE COST FOR BORINGS TO INSTALL UNDERGROUND SERVICES, PAVEMENT PATCHING OR DAMAGES TO LANDSCAPING. THESE WILL BE THE RESPONSIBILITY OF THE DEVELOPER/OWNER. ROW EASEMENT TO BE SIGNED PRIOR TO INSTALLATION OF UTILITIES. WATER METERS SUPPLIED BY CONTRACTORS SHALL CONTAIN ENCODER REGISTER AND !IRON 50W-2 PIT ERT MODULE FOR RADIO TRANSMITTED READING PER CITY OF ROCKY MOUNT STANDARDS. CONTACT CRM WATER AND SEWER SERVICES DIVISION (252-297-1317) FOR ADDITIONAL INFORMATION OR QUESTIONS. PROVIDE FIRE FLOW CALCULATIONS FOR NEW HYDRANTS. FIRE PROTECTION WATER SUPPLY SYSTEM INCLUDING FIRE HYDRANTS, SHALL BE INSTALLED AND IN SERVICE PRIOR TO RECORDING THE SUBDIVISION, OR IF NO SUBDIVISION IS INVOLVED, THE PLACING OF COMBUSTIBLE BUILDING MATERIALS FOR STRUCTURES OR COMBUSTIBLE PRE -TESTED FABRICATED BUILDING ASSEMBLIES ON THE PROJECT SITE OR UTILIZING THEM IN CONSTRUCTION OF BUILDING STRUCTURES, IF PHASED COORDINATION IS PLANNED, COORDINATE INSTALLATION OF THE FIRE PROTECTION WATER SYSTEM IS PERMITTED. FIRE DEPARTMENT VEHICULAR ACCESS, NO LESS THAN 18 FEET IN WIDTH SHALL BE PROVIDED TO ALL STRUCTURES UNDER CONSTRUCTION SHALL BE PROVIDED AT ALL TIMES. IN AREAS WHERE GROUND SURFACES ARE SOFT OR LIKELY TO BECOME SOFT, HARD ALL WEATHER SURFACE ROADS SHALL BE PROVIDED AND MAINTAINED. STREET NAMES SHALL BE APPROVED BY THE STREET NAME REVIEW COMMITTEE PRIOR TO SUBMITTAL OF A CONSTRUCTION PLAT. CONTACT SANDRA LYNCH (252) 972-1105 FOR ASSISTANCE WITH STREET NAMES. ADDRESS NUMBERS, BOTH COMMERCIAL AND RESIDENTIAL, MUST BE POSTED ON THE FRONT OF THE STRUCTURE NEAREST TO THE MAIN ENTRANCE IN A POSITION TO BE PLAINLY LEGIBLE, VISIBLE, AND UNOBSTRUCTED FROM THE STREET OR ROAD FRONTING THE PROPERTY. EVERY STREET WILL UTILIZE A COMPLETE STREET NAME CONSISTING OF A BASE NAME AND TYPE SUFFIX. (Main St.) ASSIGNED ADDRESS MUST BE ISSUED VIA CITY OF ROCKY MOUNT ADDRESSING CERTIFICATE COMPLETED BY THE CITY OF ROCKY MOUNT PLANNING DEPARTMENT ADDRESSING AGENT AND WILL BE VERIFIED THROUGH THE CITY OF ROCKY MOUNT 9-1-1 COORDINATORS OFFICE. ANY CHANGE OR DEVIATION FROM THIS PLAT, PRIOR TO OR DURING CONSTRUCTION, WILL CAUSE ADDRESSING AND / OR STREET NAMES TO BE RE-EVALUATED WITH POSSIBLE SUBSEQUENT CHANGE. CROSS CONNECTION POLICY IS AVAILABLE AT http://www.rockymountnc.gov/utllitles/crossconnectlon.html ALL NEW COMMERCIAL WATER SERVICES AND IRRIGATION SERVICES ARE REQUIRED TO HAVE TESTABLE BACKFLOW PREVENTION ASSEMBLIES (BFP). FIRE SERVICES WITH FDC OR BOOSTER PUMPS ARE REQUIRED TO HAVE REDUCED PRESSURE PRINCIPLE DETECTOR ASSEMBLIES (RPDA). FIRE HYDRANTS ARE TO UTILIZE A STORZ TYPE CONNECTION ON MAIN CONNECTION AND 2X CAPS & BONNET MUST BE COLOR CODED BASED ON THE FLOW RATE IN ACCORDANCE WITH NATIONALLY RECOGNIZED STANDARDS. STORZ CAPS ARE TO BE PERMANENTLY STAMPED WITH THE FOLLOWING: Property of the City of Rocky Mount Fire Department - Do Not Purchase As Scrap REDUCED PRESSURE ASSEMBLIES ARE REQUIRED FOR HEALTH HAZARD APPLICATIONS. DOUBLE CHECK VALVE ASSEMBUES MAY BE USED IN NON HEALTH HAZARD APPLICATIONS SUCH AS SOME OFFICE, RESTAURANT, AND RETAIL APPLICATIONS. AT LEAST ONE (1) LARGE TREE AND ONE (1) SMALL TREE SHALL BE PROVIDED ON ALL SINGLE-FAMILY RESIDENTIAL LOTS. AN SCM BOND IS REQUIRED PRIOR TO PLAN APPROVAL. • Certification by the Department of Development Services that this construction plat was approved by the city planning board on day of - 20 Director of Development Services Certification by the City Engineering Department that this construction plat and required improvement drawings meet the appropriate city standards. Director of Engineering BARTLETT ENGINEERING & SURVEYING, PC 1906 NASH STREET NORTH WILSON, N.C. 27893-1726 License No. C-1551 NO SIDEWALK 10' PUBLIC DRAINAGE 4 UTILITY EASEMENT POWER LINE. PHONE LINE 5EWER CLEAN OUT SERVICE BOX PER CRM DET. 4.12 RIGHT-OF-WAY CURB AND GUTTER NOTES: i.fy WATER, METER ury PER CRM DET. 5.5 1) LIGHT POLE D' BEHIND C4G AT PROPERTY LINE) PER CRM STD DETAIL 5.5 1. APPLIES TO NEW SUBDIVISIONS. VERIFY EXISTING LOCATIONS. 2. THIS DETAIL 15 APPLICABLE TO.BOTII SIDES OP STREET',.. ROCKY MOUNT NORTH OAIICILINA DEPARTMENT OF ENGINEERING T 2' a 0' 7,-6' 10' PUBLIC DRAINAG POWER LINE aCc. PHONE LINE.:. T. SIDEWALK UTILITY EASEMENT CABLE TV _ ... __ OUT SEWER. OUT CLEAN seRvKe BOX PER CRM DET. 4 12 RIGHT-OFWAY •A N • VEGETATIVE STRIP CURB AND GUTTER N • si PROPERTY LINE T/P:- WATER METER PER CRM DET. 5.5 LIGHT POLE (I' BEHIND C4G.AT PROPERTY LINE) • L-31 PER CRM STD DETAIL 5.5 TYPICAL RESIDENTIAL UTILITY LOCATIONS DATE: AUGUST 20I 8 APPROVED: DRAFT STANDARD #: TBD SHEET # 1. OF 1 REVISION: r 1 � ELECTRIC METER (TYPICAL. -J- GA5 METER (TYPICAL) P .. MIX (VARIES BY ZONE) BL n . -MC. N5FORMER c RAV1 CONCRETE Ct6 TY?. 5.5. Mil 55 r 7• IGHT POLE (I' BEHIND C4G AT PROPERTY UNE) PROPERTY LINE TNT. 5! PUBUC DRAINAGE 4 UTILITY EASEMENT (TOT] T • GAS 4 ELECTRICAL SERVICE MAY BE LOCATED ON OPPOSITE S1DE OF LOT THAN DRIVEWAY (TO BE COORDINATED 1 WITH ENERGY RESOURCES). (IYPeLECTRICICAL)AL SERVICE I 1 GAS SERVICE ! I (TYPICAL -,A1 Gy„ - SECONDARY '.•, JUNCTION BOX I a PO4UeA5eMeNr(IYP.) • ADC AVE. -3 •I, GAS MAIN (TYPICAL) ._.-4-WATER SERVICE (TYP CAL) (1 -PF---SEWER SERVICE (11P CAL) 5.5 MH NOTES:I. DRIVEWAYS TO BE LOCATED TO REDUCE IMPACT TO SERVICE CONECTIONS. 2. wAres MAIN LOCATION TO DE COORDINATED WITH CITY OF ROCKY MOUNT DURING CONSTRUCTION PLAN REVIEW. 3. SEE CITY OP ROCKY MOUNT STANDARD DEVELOPMENT PLANNOTES POR ADDITIONAL UTILITY INFORMATION. r - - - I DATE: AUGUST 2018 CKY MOUNT DEPARTMENT OF ENGINEERING TYPICAL PLOT PLAN DETAIL APPROVED: DRAFT STANDARD #: TBD SHEET #1 OF I - REVISION: TELE: (252) 399-0704 FAX: (252) 399-0804 www.bortlett.us.com DETAILS c-•2:1 OR PLATTER F E• 5'- D 1 i j.} HIIln,� ll rI'I i=h STREET TYPE RESIDENTriAt O^AL RESIDENTIAL. I.00AI. RESIT/ENRON colleCTOR COMMERCIAL LOCAL ~ COMMERCIAL COLLECTOR INDUSTRIAL LOCAL INDUSTRIAL COLLEGToR 46 27 135 2.0 4 GO 30 150 2O 8 STANDARD CROSS-SECTION WITH SIDEWALK .. .0.. APPROVED P' SURFACE 7 Lt t!Ii (Il Ili IIIi1 1li II - Itit I_Di- iIIIIIIIiII,JI{)II IIIII-CIA ArrroviD SUL BASE -.2:1 OR PLATTER 12' jl iI lj1 111 tI,j Iii I :Ili ilJ �I�}utll;(4ill lll.l(l......III -Ir,i L iil�R Ir 42 27 13.5 2.0 45 TNCIJOC150EED 5 ENCOURAGED a Ei7QME G SIDU: 0 35 i 175 2.0 '., 8.0 R wesIRO __. _.,..,. ONE SIDr. 65 40 200 2.0 5 5 REOIJIPJ'.D .. ONE SIDE 50 35 17 2.0- 0.5 ENCOURAGED. ONE SIDE -10 2........--- ET000RAGED 6 40 POO 2.0 5 ONE SIDE MINOR ARTEPJAL 90 A51'FTWPJAIN.DOYCITYEFGINCCR RI' -a 1IRE0 REOUiIxED OOT'H RAGESE ERCNUSIP .ONE 510 GED ENCOURAGED MAJOR ARTERIAL AS OCTERMIIIED BYCRY ENGINEER PRIVATE LOCAL (ONE WAY) ` 42 17 :8.5 2.0 8.0 PRIVATE IDCAL (TV/0 WAY) ROCKY MOUNT ' DEPARTMENT OF .ENGINEERING STANDARD CURB 4 GUTTER CROSS-SECTION �;- APPROVED BASE NOTES. I . MINIMUM LONGITUDINAL GRADE OP GUTTER IS O.4Y 2. SLOPES SHOWN POP. SIDLWAI.K-UTILTYY 511UP ARC MINIMUM. 3. SLOPES siIOWIJ OLFLADE RIGHT OP WAY ARE MAXIMUMS. 4. ALL RIGHT-OF-WAY SNAIL DE CLEARED OF TREES AND VEGETATION THAT ARE GREATER, THAN 'nIRCE WET (3) TAU. POR ADISTANCE OP 5' BACK OF THE CURD AND GUTTER. RIGFT-OF-WAY CLEARANCE ON Tt1OROUGI IPARf5 SHALL .DE A5 DETERMINED BY TIIC CITY ENGINEER. 5. WHEN DESIGNING TIIOROUGHPa2Es, Die DESIGNER 15 T0, 0.5 MUCH A5 PRACTICAL., CARRY LONGITUDINAL GRADE or DIE STREET 'El ALL EXISTING AND PROPOSED INTERSECTING STREETS TO PREVENT HUMPS NEAR GUTTER. G. STANDARD CURB 4 GUTTER PER STD NO. 2.4 RCOUIRED ONALL COLLECTORS, h(INOR MDEPJAL5, 4 MAJOR M;TEKIAI5. 7. STANDARD CURB OK ROLL TYPE (3TD. NO. 2.4 OR 2.5) SHALL BC RCOUIREO ON LOCAL AND CULDE.SAC STRELT TYPES, e. PRIVATE. SIREEl9 MAY DE REQUIRED 10 HAW GIG AT SPL'CIf1L'D LOCATIONS ALONG THE STREET AS DETERMINED DY CITY ENGINEER. 'DATE: JULY2O18 REV. MAY 2019 ;APPROVED:„- _ STANDARD # 2 I ,,HEFT C 1 OF) REVISION: A.H.C. (AVG. DEPTI 2'-6" CURB AND GUTTER 4') 1/0' RAD. JOINT SEALER I/W RAO. SURFACE OF GUTTER v2‘....-N JOINT FILLER TRANSVERSE EXPANSION JOINT IN CURB AND GUTTER GENERAL NOTE S1 ALL CURB AND GUTTERS ARE TO BC POURED WITH CLASS -A' CONCRETE (3000 PSI) fLE%ABLE FORMS ARE TO DE USED WHEN RADII IS LESS THAN 200'. CONTRACTION JOINTS SHALL BE SPACED AT 10' INTERVALS, EXCEPT THAT A 15' SPACING MAY DE USED WHEN A MIACHINE IS USED OR WHEN SATISFACTORY SUPPORT FOR THE FACE FORM CAN BE OBTAINED WITHOUT THE USE OF TEMPLATES AT 10' INTERVALS. JOINT SPACING MAY BE ALTERED BY THE ENGINEER TO PREVENT UNCONTROLLED CRACKING, CONTRACTION. JOINTS MAY BE INSTALLED BY THE USE OF TEMPLATES OR FORMED BY OTHER APPROVED METHODS. WHERE SUCH JOINTS ARE NOT FORMED BY TEMPLATES, A MINIMUM DEPTH OF 1 1/2' SHALL BE OBTAINED. ALL EXPANSION JOINTS SHALL BE FILLED WITH JOINT FILLER AND SEALED. EXPANSION JOINTS SIIALL BE SPACED AT 90' MAX. INTERVALS AND ADJACENT TO ALL RIGID OBJECTS (I.E: EXISTING DRIVE- WAYS, CURD D GUTTER. SIDEWALK, ETC.). STANDARD 30' CURB & GUTTER CROSS-SECTION REVISIONS Nn DATE DESCRIPTION CITY =1F ROCKY MOUNT DEPT OF ENGINEERING APPROVED STD. NO. 2.4 DAIL 09-24-08 REVISION ' E-111=HE1111±1 III---I_1 II_.1,� I . 6' MIN. NOTES: I . PLEASE REFER TO NCOOT STANDARD DETAIL 300.01. 2. ALL REINI'ORCED CONCRETE PIPE MUST 0E NCODT APPROVED (STAMPED), ROCKY MOUNT DEPARTMENT OF 1 ENGINEERING WHEN NO TRENCH BOX REQUIRED (IYPICAtJ STANDARD BEDDING DETAILS FOR REINFORCED CONCRETE PIPE COMPACTED BACIPILL, TAMPED IN G' LIFTS. BACKPILL ACCORDING TO NCDOT ^-" SPECIFICATIONS, SECTION 1016 SELECT MATERIALS UNDISTURBED SOIL #57 STONE DATE: AUGUST 2017 STANDARD"# 1.6 APPROVED: • SHEET # IOF 2 '_. REVISION: OLDE MILL STREAM (PHASE 2) CITY OF ROCKY MOUNT, NC - • • VW ' t+ 4', R ry 6-3/4) A/41R 4 6" MEDIAN CURB AND GUTTER SIDE ELEVATION I/O' RAD. + JOINT SEALER t/8' RAD. SURFACE OF GUTTER GENERAL NOTES. ALL CURB AND GUTTERS ARE TO DE POURED WITH CLASS 'A' CONCRETE, C3000 PSI) FLEXABLE FORMS ARE TO BE USED WHEN RADII IS LESS THAN 200'. CONTRACTION JOINTS SHALL. BE SPACED AT 10' INTERVALS. JOINT SPACING MAY BE ALTERED BY THE ENGINEER TO PREVENT UNCONTROLLED CRACKING. CONTRACTION JOINTS MAY BE INSTALLED BY THE USE OF TEMPLATES OR FORMED BY OTHER APPROVED METHODS. WHERE SUCH JOINTS ARE NOT FORMED BY TEMPLATES A MINIMUM DEPTH OF 1 t/2' SHALL BE OBTAINED. ALL CONTRACTION JOINTS SHALL BE FILLED WITH JOINT FILLER, EXPANSION JOINTS SHALL BE SPACED AT 90' MAX. INTERVALS, 1/2' JOINT FILLER ADJACENT TO ALL RIGID OBJECTS. TRANSVERSE EXPANSION JOINT IN CURB AND GUTTER STANDARD 18' MEDIAN CURB & GUTTER REVISIONS NO PATF DFSCRTPTTPN CITY OF ROCKY MOUNT DEPT. OF ENGINEERING APPROVED STD. NO. 2,6 DATE 02-26-03 0 \ a h��4 44 1)1 0 a; Lv CV N to4 11111e.11.111119 * ROW SHALL BE 46' WHERE SIDEWALK IS PROVIDED ON BOTH SIDES tP� •s. NoP STANDARD CUL-DE-SAC TURN -AROUND REVISION REVISIONS Nn WIT hrSCRTPTIFIN CITY OF ROCKY MOUNT DEPT. OF ENGINEERING APPROVED STD. NO. 2.8 DATE 07-15-04 REVISION NOTES MATERIAL CLASSIFICATIONS: cCLLAA55551 SHELECT MATLFJAL 15 A SE TY OR CLAYEY SOIL MATERIAL MELTING AASILITO M 145 FOR S011 CLASSINCATION A.4. SOIL MCALTAESRISALI5 %LATCH MEET APSITTO Pi 145 FOR 5011- CIASSINCADON A-2, A-5, A.6 AM) A-7 ARE ACCEPTABLE PROVIDED SUCH MATEIRAL5 DO NOT NAVE A LL GREATER THAN 50, NOR. A PI OF 1.1155 LILIAN 7 OR GREATF.R THAN 20. TYPE: / SELECT MATERIAL 'TYPE I SELECT MAI 22bv. 15 A NTT AGGREGATE MATERIAL CONSISTING OF CRUSHED STONE SCREENINGS (WASHED OR TWE 2 SELECT t4ATERIAL 15 A GRANULAR SOIL MATEPJAL MEETING AASMO M 145 FOR SOIL CLA55IEICATION5 A•2.41 WITI1 A MAXIMUM Fl OP G AND A-4 SOIL CONTAINING 45% MAXIMUM PASSING A NO. 200 SIEVE AND A MAXIMUM PI OIL G. WcHLEA:5TYPHE1 15 NETT sreanco, citherelyee MAY BE USED. But NO ADDITIONAL COMPENSATION WEL BE MADE. TYPE / SELECT MMEIJA1 WEE I SELECT MATERIAL IS A NATURAL Ok MANUFACTURED FIN AGGREGATE MATERIAL MEETING TIT GRADMION TYPE 2 SELECT MATERIAL TYPE 2 SWOT MATERIAL 15 A GRANULAR 50IL MATEPJAI. MEETING PASHTO M 145 FOR SOIL CLASSIFICATION A -I OR A-3. MIEN A TYPE IS NOT SPECIPIED. Ell HER TYPE MAY BE USED, BUT NO ADDITIONAL COMPENSATION WILL HE MADE. CLASS IV AchAsc A55 1V0L551!cligertAIDAITNEsgrlAtTli5oNA ?00AR..0.91! AGGREGATE MATERIAL MetTING THE GP.ADATION REQUIREMENTS OF STANDARD IZE CLASS V cm55 V SELECT MATERIAL IS A COARSE AGGREGATE MATfr7.1AL MEETING THE GRADATION REQUIREMENTS Of STANDARD SIZE PI tin" "Fin OPIA DEPARTMENT OF ENGINEERING STANDARD BEDDING DETAILS FOR REINFORCED CONCRETE PIPE REVISION: • DATE AUGUST 2020 SCALE(HORZ): SCALE(VERT): PROJECT: 20-042 CLIENT CODE: RHC CADFILE: 20042CP7 FIELD BOOK: DRAWN BY: RF SURVEY BY: KP, JB ROCKY MOUNT TWNSP NASH COUNTY NORTH CAROLINA ZONE: R-6 & 0-1 REVISIONS: CRM 2ND REVIEW COMMENTS 10/28/2020 CRM 1ST REVIEW COMMENTS 10/13/2020 SHEET CP10 cn co 0 0 0.1 a. cy ,c b2ia.s.4••sii r VEGETATED SHELF EMERGENCY SPILLWAY WITH TURF REINFORCEMENT MAT X ." X X / ` X X X ?�� X X X_.. �.. v , X >` .\ X1; <X1\ 1 1 30 PUBLIC SE _. ;' w�R GSM T. / WET POND 1 1" = 301 `•. X 1 ) Xi/ -- - 1 . / '• X ' )4." � X i �`X` ;\X 7j X\.\ XX . N 4. 4') •--50'_- . \ 20' EMERGENCY SPILLWAY (EL. 124. \ � \ \` \`r rr X �` i \�i \ /""! \ • • \1•"\%/CN \ "r • i • X fiX " HORIZONTAL .,LUMINUM EARS ARE NOT HOW'N FOR CLARITY r_ CUB ID 1 4' N 4" A' 4' 4' 6" SECTION V EW IF WALL IS a" HINGE ONE OUADRANT FOR MANLVAY ACCESS �4 PLAN VIEW 6„ SQUARE 36"' I.D. SQUARE SECTION VIEW 2"x 2" Xi" ALUMINUM ANGLES i EACH CORNER DLA. MTG HOLES (p9 REQ'O) V.%TH? SST V.EDGE ANCHORS HOLE CENTERS TO BE A" FROM THE OUTSIDE EDGE OF THE PLATE) ir Xl"ALUMINUMBARS SPACED 4` O.C. ig BASE FRAME --a" ALUMINUM- PLATE FRAME 4E' X 4a' X 6' WIDE -- :2"X.2"XI" ALUMINUM ANGLE IQ EACH CORNER LIFT LUG PER FABRICATOR 6" X 6 X2" ALUMINUM TOP =-.-PLATE .�" Xi" ALUMINUM EARS SPACED HORIZONTALLY \,A S SHOWN: ' 4„ SECTION WEW IF WALL IS 4" ACCOMMODATES A 35' X 36" I.D. FOR BOTH A 4" AND 5' WALL I'`O MONA RE P�ODUC1'9 WwtMCM! *UPPLY CO411NIIY STANDARD ALUMINUM BAR 8 ANGLE PEAKED ROOF TRASH RACK WITH ONE. QUADRANT HINGED FOR MANWAY ACCESS TO flT AM' X 36" I.D.. CONCRETE RISER WITH 4 „ 5 „ OR 6" THICK WALLS TRASH RACK NO SCALE 0 EL. 124' 3' WEIR EL. 122.3' 4" PVC INV. EL. 121' 24" RCP INV. EL. 121' SAMIIIIIIN .4112/411/1111111111111,111� RISER ANTI -FLOATATION BLOCK ALUMINUM TRASH RACK MOUNTED ON STRUCTURE EL. 124' 4" PVC CAP WITH 2"0J ORIFICE HOLE DRILLED 4" PVC STUBBED INTO BOX (INVERT ELEV.= 121') / 121' EL // .: CONCRETE FILL •.'/ 46" CONCRETE BASE RISER BOX(C nde Blocks) I ANTI -FLOTATION BLOCK TOTAL LENGTH I WIDTH , THICKNS DEPTH # BLOCKS WEIGHT IDISPLACD: LENGTH WIDTH THICKNS I PROP. WT INCH 1 INCH INCH , FT PCS LBS I H2OLBS FT FT INCH l LBS *REQ. W T.'i LBS 3 * REQUIRED WEIGHT MUST BE 110% OF THE WEIGHT OF4DISPLACED WATER'' OUTLET STRUCTURE NO SCALE 3 6 5185.96 14942.08 24" RCP BERM SOIL AND COMPACTION SPECIFICATIONS: 1 ALL FILL SOILS FOR BERM SECTION SHALL BE CLEAN, IMPERMEABLE MATERIAL AND COMPACTED TO AT LEAST 95% STANDARD PROCTOR MAXIMUM DRY DENSITY, AT OPTIMUM MOISTURE CONTENT, NO BLASTED MATERIALS SHALL BE USED IN THE EMBANKMENT CONSTRUCTION. SOILS SHALL NOT EXHIBIT SIGNIFICANT SHRINK/SWELL OR DISPERSIVE CHARACTERISTICS. ON -SITE GEOTECHNICAL ENGINEER SHALL APPROVE THE SOILS FOR PLACEMENT WITHIN THE BERM SECTION. THE GEOTECHNICAL ENGINEER SHALL ALSO SPECIFY THE METHODS TO BE USED FOR PLACEMENTS OF FILL. IF ADDMONAL USES PLANNED UPON THE BERM SECTION (BUILDINGS, ETC.), THE GEOTECHNICAL ENGINEER SHALL SPECIFY SOILS SUITABLE FOR THAT ADDMONAL USE, IN ALL FILL AREAS OF THE BERM, A SOILS COMPACTION TEST SHALL BE CONDUCTED EACH 2500 SQUARE FEET PER VERTICAL FOOT OF FILL. 2. NO TREES OF ANY TYPE MAY BE LOCATED ON THE BERM SECTION. 3 FILL PLACEMENT SHALL NOT EXCEED A MAXIMUM 8 UFT. EACH LIFT SHALL BE CONTINUOUS FOR THE ENTIRE LENGTH OF EMBANKMENT. BEFORE PLACEMENT OF FILL FOR THE BERM SECTION, ALL UNSUITABLE MATERIAL SHALL BE REMOVED AND THE SURFACE PROPERLY PREPARED FOR FILL PLACEMENT. SEEDBED PREPARATION: CHISEL COMPACTED AREAS AND SPREAD TOPSOIL 3" DEEP OVER ADVERSE SOIL CONDMONS, IF AVAILABLE. RIP ENTIRE AREA 8" DEEP. REMOVE ALL LOOSE ROCK, ROOTS, AND OTHER OBSTRUCTIONS LEAVING SURFACE REASONABLY SMOOTH AND UNIFORM. APPLY AGRICULTURAL LIME AND FERTILIZER UNIFORMLY AND MIX WITH SOIL, CONTINUE TILLAGE UNTIL A WELL PULVERIZED, REASONABLY UNIFORM SEEDBED IS PREPARED 4" TO 8" DEEP. SPREAD SEED ON FRESHLY PREPARED SEEDBED AND COVER UGHTLY WITH SEEDING EQUIPMENT OR CULTIPACKER AFTER SEEDING. MULCH IMMEDIATELY AFTER SEEDING AND ANCHOR MULCH, VEGETATION: UPON CONVERSION FROM SEDIMENT BASIN, THE SCM SHELF WILL BE PLANTED AND DAM & SLOPES SEEDED AS PER NCDEQ MANUAL TOPSOIL STRIPPED FROM SITE TO BE PLACED BACK ONTO THE VEGETATIVE SHELF (PLANTING SHELF) PRIOR TO PLANTING. NO FERTILIZATION IS TO BE USED AFTER THE INITIAL PLANTING. THE LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR DETERMINING SOIL CHARACTERISTICS AND NEEDED FERTILIZER APPLICATION. AT THE END OF THE FIRST YEAR AND AGAIN AFTER THE SECOND YEAR OF OPERATION, ANY PLANTS THAT Do NOT SURVIVE MUST BE REPLACED WITH A SIMILAR VARIETY AND PLACEMENT BY THE LANDSCAPING CONTRACTOR. DMA AND SLOPES TO BE RE -SEEDED AS NECESSARY. DAM & EMBANKMENT SLOPES FPDING MIXTURE SPECIES JjATF(I R/ACRF), SEEDING DATES BERMUDA GRASS 80 4/15-8/15 PFRIMFTER SHELF AREA = 2300 SF REQUIREMENT= 50 PLANTS/200 SF OF SHELF PLANTS REQUIRED= 2300/200+50 = 535 PLANTS PLANT NAME ASCELEPIAS INCARNATA (SWAMP MILKWEED) HIBISCUS COCCINEUS (SCARLET ROSE MALLOW) LOBELIA ELONGATA (LONGLEAF LOBELIA) QTY 70 70 395 SPACING 3' 3' 1.5' REQUIRED SIZE 4" POTS 4" POTS 4" POTS DRAINAGE BASIN SUMMARY STORM EVENT EXISTING POST WITH SCM % REDUCTION/ INCREASE 1-YR 25.74CFS 15.18CFS -41% 10-YR 129.59CFS 106.98CFS -17% 25-YR 205.63 CFS 188.28 CFS -8% TOP ELEV 126' 1 FROM STORM DRAINAGE SYSTEM FOREBAY BOTTOM 0 ELEV. 116' FOREBAY SEDIMENT CLEANOUT ® ELEV. 115' Main Pool Volume Elevation Area Incremental Storage Volume Volume 115.00 5,212.54 0.00 0.00 116.00 5,916.38 5,560.75 5,560.75 117.00 6,651.44 6,280.33 11,841.08 118.00 7,411.64 7,028.11 18,869.19 119.00 8,196.97 7,801.01 26,670.20 120.00 9,007.43 8,599.02 35,269.22 121.00 9,843.02 9,422.14 44,691.35 OKI 44 691 35 Total storage volume - Required volume: 44,269.98 POND DESIGN DATA Wet Detention Pond #1 1 j Drainage Built BUA/DA Runoff Storm Water Area Upon Coefficient Rainfall Quality Area (DA) (BUA) Depth Volume (Rv) (Rd) (WQv) 552,620sf 211,609Isf 0.38 0.39' 11in - 18,173!cf Main Pool (HRT Method) Provided Required Provided Pond and (VMP) (MPV) Volume ForebaV 44,2701cf 44,691 1,1791cf 2 i !cf 64j% Main Pool Main Pool Forebay Volume Forebay Volume/Main Volume Volume • Drawdown Orifice (WQv) 18,173cf 122 121 2 0 0 I 2 301 00'ft OO,in 461 ft 07icfs 95'days Water Temporary Normal Orifice Driving Discharge Drawdown Quality size Head Pool time Pool Elevation (Ho/3) Volume Elevation NORMAL POOL EL.= 121' 4" PVC CAP WITH LED ORIFICE HOLE DRILLED TYPICAL PREFORMED SCOUR HOLE LAYOUT AND COMPONENTS (NCDOT BMP TOOLBOX V2 2014) PIPE d-24 PLUNGE POOL 10'x12.e' (RIPRAP NOT SHOWN FOR CLARITY) UNER. CLASS 8 RIPRAP d50-6" WITH TYPE 2 FILTER FABRIC PIPE d=24" DEPTH OF SCOURHOLE-1.5' W=STANDARD ROLL WIDTH PERMANENT SOIL REINFORCEMENT MATTING (PSRM). PSRM SHALL BE SEEDED WITH VEGETATION AT INSTALLATION. PRSEM INSTALL LEVEL AND FLUSH WITH NATURAL GROUND GROUND DEPTH OF RIPRAP-1.0' I 1.9 ASE WID MIN. 1' TUCK NOTE: SIDE SLOPES ALONG THE WIDTH IS 2:1 SCOUR HOLE No Scale 3.0' RECTANGULAR WEIR (ELEV= 122.3') POND BOTTOM 0 ELEV. 115' -- -- -- -- -- -- -- -- -- POND BOTTOM WITH 1.0SEDIMENT CLEANOUT ® ELEV. 114' WET RETENTION POND & RISER SECTION No Scale BARTLETT ENGINEERING & SURVEYING, PC 1906 NASH STREET NORTH WILSON, N.C. 27893-1726 License No. C-1551 TELE: (252) 399-0704 FAX: (252) 399-0804 www.bartlett.us.com WET POND 1 DETAILS TOP ELEV 126' 20' WEIR ELEV 124.4' 46 LF ® S=1.0% 24" RCP 6' VEGETATED SHELF (S=6:1) 36"x36" OUTLET STRUCTURE TOP ELEV= 124' 3.0' RECT. WEIR ELEV= 122.3' INV. IN (4" PVC) = 121' INV. OUT (24" RCP) = 121' ANTI -SEEP COLLAR MINIMUM PROJECTION 1.5 FT. OUTSIDE OF PIPE RIPRAP LINED PLUNGE POOL FOR CANTILEVER OUTLET (Version 8.99) (Reference Design Note No. 6 (Second Edition), Jan. 23, 1986 JOB: Olds Mill Stream Pond 1 Outlet DESIGNER: CHECKER* INPUT DATA: Conduit Diameter Conduit Discharge: Conduit Slope at Outlet: Conduit Outlet Invert Elevation: Tailwater Elevation: Outlet Channel Invert Elevation: Water Density: Bed/Riprap Particle Density: (Default 2.64) D, 50 Riprap Size: Riprap Thickness: (2.5*D, 50 recommended) Bedding Thickness: (6 inch min. rec.) (Enter 0 for geotextile) Side Slope Ratio: Upstream End Slope Ratio: Downstream End Slope Ratio: Combined End Slope Ratio: OUTPUT ---POOL LOCATION AND DIMENSIONS: Vert. Dist. from Tailwater to Conduit Invert: Submergence Check: (If Zp < 0 , Use Zp = 0) Beaching Check: (Q/(gD^5)^0.5 <_ (1 0+25*D150/D)) **Beaching Controlled** Distance from Conduit Exit to C/L Pool: Pool depth at C/L Below Conduit Invert: Pool Bottom Elev: Pool Bottom Length: Pool Bottom Width: Upstream Pool Length at Tailwater Elev.: Downstream Pool Length at Tailwater Elev.: Pool Width at Tailwater Elev.: Check Side Slope Ratio: (Wr>=We) **Side Slope Ratio Zw O.K.** Check Min. End Slope Ratio: (Lru & Lrd >= Le) **End Slope Ratios O.K.** Check Upstream Length: (Lru >= Xm) **End Slope Ratio ZIu O.K.** Pool Bottom Elev. at Bottom of Riprap: Pool Bottom Elev. at Bottom of Bedding: OUTPUT ---VOLUMES BELOW WATER SURFACE ELEVATION: Volume of Excavation (measured from bottom surface of bedding): Volume of Rock Riprap: Area of Geotextite: Date: Date: D= Q= S= El, CO = EI, TW = El CH = RHO = RHOS = RS = RT = BT = Zw = ZIu = Zid = Z1 = Zp = Use Zp = Xm = Zp+0.8Zm = EI,PB = 2Lr2 = 2Wr2 = Lru = Lrd = 2Wr= El, BR = El, BB = V,pbs = V,rs = A,gt = Spreadsheet developed by D. Hurtz, Midwest NTC, 1/90 Spreadsheet modified by M. Dreischmeier, Eau Claire TC, Wis., 3/98 Design Note No. 6 (Second Edition), Jan. 23, 1986 8/14/2020 2.00 17.59 0.01 120.54 120.00 120.00 1.00 2.64 0.50 1.00 0.00 2.00 2.00 2.00 2.00 ft cfs ft/ft ft ft ft ft ft ft ft/ft ft/ft ft/ft ft/ft 0.54 ft 0.54 ft O.K. 2.94 2.05 118.49 1.27 1.19 3.64 3.64 7.21 O.K. O.K. O.K. ft ft ft ft ft ft ft ft 117.49 ft 117.49 ft 5.0 cu yd 3.8 cu yd 22.2 sq yd OLDE MILL STREAM (PHASE 2) - CITY OF ROCKY MOUNT, NC TOP ELEV 126' ELEV=124.4' ELEV=122' 1,0' 1 + FREEBOARD 3 ELEV=121' 6' PERIMETER SHELF POND X SECTION No Scale FULL POOL 121' POND BOTTOM © ELEV. 115' POND BOTTOM WITH 1.0' SEDIMENT CLEANOUT © ELEV. 114' TOP ELEV 126' TOP ELEV 126' 1 3 1.0'± FREEBOARD 3 EMERGENCY SPILLWAY ELEV 124.4' TURF REINFORCEMENT MAT (NORTH AMERICAN GREEN SC-250) EMERGENCY SPILLWAY X-SECTION No Scale PRINCIPAL SPILLWAY USE ONLY APPROVED WATERTIGHT ASSEMBLIES FOR ALL PIPE CONNECTIONS. PLACE BARREL AND RISER ON FIRM, EVEN FOUNDATION. INSTALL ANTI -SEEP COLLAR(S) SUGHTLY DOWNSTREAM OF DAM CENTERLINE (MINIMUM PROJECTION 1.5 FT.). PLACE MOIST, CLAYEY, WORKABLE SOIL AROUND PIPE AND ANTI -SEEP COLLARS. DO NOT USE PERVIOUS MATERIAL SUCH AS SAND, GRAVEL, OR SILT. COMPACT 4-INCH LAYERS OF SOIL, BY HAND, UNDER AND AROUND PIPE AND COLLARS TO AT LEAST THE DENSITY OF FOUNDATION SOIL. AVOID RAISING PIPE FROM FIRM CONTACT W1TH FOUNDATION WHILE COMPACTING MATERIAL UNDER PIPE HAUNCHES. • COVER PIPE TO A DEPTH OF 2 FT. MINIMUM OF HAND -COMPACTED BACKFILL BEFORE CROSSING IT WITH CONSTRUCTION EQUIPMENT. DATE: AUGUST 2020 SCALE(HORZ): SCALE(VERT): Certification by the Department of Development Services that this construction plat was approved by the city planning board on _ day of 20 Director of Development Services Certification by the City Engineering Department that this construction plat and required improvement drawings meet the appropriate city standards. Director of Engineering PROJECT: 20-042 CLIENT CODE: RHC CADFILE: 20042CP7 FIELD BOOK: DRAWN BY: RF SURVEY BY: KP, JB ROCKY MOUNT TWNSP NASH COUNTY REVISIONS: PIN # SHEET SCM1 cn • tr 0 0 a. oI • i'i�i�i�i�i�i• .sovo� 175-l- -123 i VEGETATED SHELF EMERGENCY SPILLWAY WITH TURF REINFORCEMENT MAT n ri 11. as so so IsmI PAM & EMBANKMENT SLOPES REDING MIXTURE SPECIES RATE(LB/ACRE) SFFDING DATES BERMUDA GRASS 80 4/15-8/15 PERIMETER SHELF AREA = 3956 SF REQUIREMENT= 50 PLANTS/200 SF OF SHELF PLANTS REQUIRED= 2300/200+50 = 989 PLANTS PLANT NAME ASCELEPIAS INCARNATA (SWAMP MILKWEED) HIBISCUS COCCINEUS (SCARLET ROSE MALLOW) LOBELIA ELONGATA (LONGLEAF LOBELIA) QTY 129 129 731 SPACING 3' 3' 1.5' REQUIRED SIZE 4" POTS 4" POTS 4" POTS DRAINAGE BASIN SUMMARY STORM EVENT EXISTING POST WITH SCM % INCREASE REDUCTION/ 1-YR 25.74CFS 1518CFS -41% 10-YR 129.59 CFS 106.98 CFS -17% 25-YR 205.63 CFS 188.28 CFS -8% 30" RCP -3 FROM STORM DRAINAGE SYSTEM TOP ELEV 126' FOREBAY 2 BOTTOM © ELEV. 119' FOREBAY SEDIMENT CLEANOUT ® ELEV, 118' • -1- 1 1 1 1 30' EMERGENCY SPILLWAY (EL. 124.3') • N. N. NNN • • ` • • • P Niet PLUNdE,f COL -L 120-I- 1-I- -I- + -I- -I { + I I -k _ .dr` + + + + + + + +1 + + + + + ��+ + + + " + + + + + -I- + -I- + 1 + + -I- -I- + + I F - - +120- + + -I- -+ "-:3:4; + + -I- + + + + + + 11 -I- + + + + -I- + + + + - + + �\ • • • 7 • • 184, \ • • WET POND 1 1"=30' Main Pool Volume POND DESIGN DATA i Wet Detention Pond #2 1 Elevation Area Incremental Storage Volume Volume Dranage Built BUA/DA Runoff Storm Water Upon Area (DA) Area (BUA) Coefficient (Rv) Rainfall Depth Quality Volume (Rd) (WQv) 1,067,143 304,227 0.29 0.31 i 1 27,263 sf sf in cf 1 , I 118.00 18,403.74 0.00 0.00 119.00 20,180.86 19,285.47 19,285.47 120.00 21,987.39 21,077.67 40,363.14 121.00 23,821.20 22,898.17 63,261.32 121.50 24,747,53 12,141.45 75,402.76 Total storage volume - OKI 75,402.76 Required volume: i 66,413.72 Main Pool (HRT Method) Required Protided Provided Pond and (VMP) (MPV) Volume Forebay 66,414 75 403icf 1,179 1.56 cf cf Main Pool Volume Main Pool Volume Forebay Volume Forebay Volume/Main Orifice (WQv) 27,263 122.40 ! 121.50 I 3.00 1 0.34 i 0.14 • 2.28 cf ft ft j in ft i__..._ cfs i days ........_ Drawdown Water Temporary Normal Onfice Doting Discharge Drawdown Quality Volume Pool Elevation Pool Elevation size Head (Ho/3) time 30' WEIR ELEV 124.3' NORMAL POOL EL= 121.5' _POND BOTTOM ® ELEV. 118' POND BOTTOM WITH 1.0 SEDIMENT CLEANOUT ® ELEV. 117' BARTLETT ENGINEERING & SURVEYING, PC 1906 NASH STREET NORTH WILSON, N.C. 27893-1726 License No. C-1551 TELE: (252) 399-0704 FAX: (252) 399-0804 www.bartlett.us.com WET RETENTION POND SECTION No Scale WET POND 2 DETAILS 2�\ TYPICAL PREFORMED SCOUR HOLE LAYOUT AND COMPONENTS (N000T BMP TOOLBOX V2 2014) PIPE d=18" PLUNGE POOL 8.8'x11 (RIPRAP NOT SHOWN FOR CLARITY) LINER. CLASS B RIPRAP d50=4" WITH TYPE 2 FILTER FABRIC PIPE d=18" DEPTH OF SCOURHOLE=0.4' WaSTANDARD ROLL WDTH PERMANENT SOIL REINFORCEMENT MATTING (PSRM). PSRM SHALL BE SEEDED WITH VEGETATION AT INSTALLATION. PRSEM INSTALL LEVEL AND FLUSH WITH NATURAL GROUND GROUND DEPTH OF RIPRAP=1.0' 1.6 ASE WD MIN. 1' TUCK NOTE: SIDE SLOPES ALONG THE WIDTH IS 2:1 SCOUR HOLE No Scale TOP ELEV 126' FOREBAY 1 BOTTOM 0 ELEV. 119' FOREBAY SEDIMENT CLEANOUT © ELEV. 118' 42" RCP FROM STORM DRAINAGE SYSTEM EL. 124' 0 3' WEIR EL. 122.4' 6" PVC INV. EL. 121.5' 18" RCP INV. EL. 121.5' RISER ANTI -FLOATATION BLOCK RISER BOX(C ode Blocks) LENGTH I WIDTH I, THICKNS DEPTH #BLOCKS INCH INCH INCH FT PCS ALUMINUM TRASH RACK MOUNTED ON STRUCTURE (DETAILS ON SHEET SCM2) EL. 124' 6" PVC CAP WITH 3"0 ORIFICE HOLE DRILLED 6" PVC STUBBED INTO BOX (INVERT ELEV.= 121.5') WEIGHT DISPLACD LBS H2OLBS EL 121.5' 2 Z 7 CONCRETE 4: ALL • • ;'46" CONCRETE BASE ANTI -FLOTATION_ BLOCK TOTAL I LENGTH WIDTH l THICKNS PROP. Wf *REQ. WT. FT FT ; INCH LBS I LBS 36 1 36 1 .___..6 3.5 47.5 394709 3993.60 3 3 , * REQUIRED WEIGHT MUST BE 110% OF THE WEIGHT OF DISPLACED WATER OUTLET STRUCTURE NO SCALE 6 4622.09 4392.96 18" RCP BERM SOIL AND COMPACTION SPECIFICATIONS: 1 AU. FILL SOILS FOR BERM SECTION SHALL BE CLEAN, IMPERMEABLE MATERIAL AND COMPACTED TO AT LEAST 95% STANDARD PROCTOR MAXIMUM DRY DENSITY, AT OPTIMUM MOISTURE CONTENT. NO BLASTED MATERIALS SHALL BE USED IN THE EMBANKMENT CONSTRUCTION. SOILS SHALL NOT EXHIBIT SIGNIFICANT SHRINK/SWELL OR DISPERSIVE CHARACTERISTICS. ON -SITE GEOTECHNICAL ENGINEER SHALL APPROVE THE SOILS FOR PLACEMENT WITHIN THE BERM SECTION. THE GEOTECHNICAL ENGINEER SHALL ALSO SPECIFY THE METHODS TO BE USED FOR PLACEMENTS OF FILL. IF ADDMONAL USES PLANNED UPON THE BERM SECTION (BUILDINGS, ETC.), THE GEOTECHNICAL ENGINEER SHALL SPECIFY SOILS SUITABLE FOR THAT ADDITIONAL USE. IN ALL FILL AREAS OF THE BERM, A SOILS COMPACTION TEST SHALL BE CONDUCTED EACH 2500 SQUARE FEET PER VERTICAL FOOT OF FILL. 2. NO TREES OF ANY TYPE MAY BE LOCATED ON THE BERM SECTION. 3 FILL PLACEMENT SHALL NOT EXCEED A MAXIMUM 8 UFT. EACH LIFT SHALL BE CONTINUOUS FOR THE ENTIRE LENGTH OF EMBANKMENT. BEFORE PLACEMENT OF FILL FOR THE BERM SECTION ALL UNSUITABLE MATERIAL SHALL BE REMOVED AND THE SURFACE PROPERLY PREPARED FOR FILL PLACEMENT. SEEDBED PREPARATION: CHISEL COMPACTED AREAS AND SPREAD TOPSOIL 3" DEEP OVER ADVERSE SOIL CONDITIONS, IF AVAILABLE. RIP ENTIRE AREA 6" DEEP. REMOVE ALL LOOSE ROCK, ROOTS, AND OTHER OBSTRUCTIONS LEAVING SURFACE REASONABLY SMOOTH AND UNIFORM. APPLY AGRICULTURAL UME AND FERTILIZER UNIFORMLY AND MIX WITH SOIL. CONTINUE TILLAGE UNTIL A WELL PULVERIZED, REASONABLY UNIFORM SEEDBED IS PREPARED 4" TO 6" DEEP. SPREAD SEED ON FRESHLY PREPARED SEEDBED AND COVER LIGHTLY WITH SEEDING EQUIPMENT OR CULTIPACKER AFTER SEEDING. MULCH IMMEDIATELY AFTER SEEDING AND ANCHOR MULCH. VEGETATION: UPON CONVERSION FROM SEDIMENT BASIN, THE SCM SHELF WILL BE PLANTED AND DAM & SLOPES SEEDED AS PER NCDEQ MANUAL. TOPSOIL STRIPPED FROM SITE TO BE PLACED BACK ONTO THE VEGETATIVE SHELF (PLANTING SHELF) PRIOR TO PLANTING. NO FERTIUZATION IS TO BE USED AFTER THE INITIAL PLANTING. THE LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR DETERMINING SOIL CHARACTERISTICS AND NEEDED FERTILIZER APPUCATION. AT THE END OF' THE FIRST YEAR AND AGAIN AFTER THE SECOND YEAR OF OPERATION, ANY PLANTS THAT DO NOT SURVIVE MUST BE REPLACED WITH A SIMILAR VARIETY AND PLACEMENT BY THE LANDSCAPING CONTRACTOR. DAM AND SLOPES TO BE RE -SEEDED AS NECESSARY. RIPRAP LINED PLUNGE POOL FOR CANTILEVER OUTLET (Version 8.99) (Reference Design Note No. 6 (Second Edition), Jan. 23, 1986 JOB: DESIGNER: CHECKER: Olde Mill Stream Pond 2 Outlet INPUT DATA: Conduit Diameter Conduit Discharge: Conduit Slope at Outlet: Conduit Outlet Invert Elevation: Tailwater Elevation: Outlet Channel Invert Elevation: Water Density: Bed/Riprap Particle Density: (Default 2.64) D, 50 Riprap Size: Riprap Thickness: (2.5*D, 50 recommended) Bedding Thickness: (6 inch min. rec.) (Enter 0 for qeotextile) Side Slope Ratio: Upstream End Slope Ratio: Downstream End Slope Ratio: Combined End Slope Ratio: OUTPUT ---POOL LOCATION AND DIMENSIONS: Vert. Dist. from Tailwater to Conduit Invert: Submergence Check: (If Zp < 0 , Use Zp = 0) Beaching Check:(Q/(gD^5)^0.5 <=(1.0+25*D,50/D)) **Beaching Controlled** Distance from Conduit Exit to C/L Pool: Pool depth at C/L Below Conduit Invert: Pool Bottom Elev: Pool Bottom Length: Pool Bottom Width: Upstream Pool Length at Tailwater Elev.: Downstream Pool Length at Tailwater Elev.: Pool Width at Tailwater Elev.: Check Side Slope Ratio: (Wr>=We) **Side Slope Ratio Zw O.K.** Check Min. End Slope Ratio: (Lru & Lrd >= Le) **End Slope Ratios O.K..** Check Upstream Length' (Lru >= Xm) **End Slope Ratio Ziu O.K.** Pool Bottom Elev. at Bottom of Riprap: Pool Bottom Elev. at Bottom of Bedding: OUTPUT ---VOLUMES BELOW WATER SURFACE ELEVATION: Volume of Excavation (measured from bottom surface of bedding): Volume of Rock Riprap: Area of Geotextile: Date: Date: D= Q= S= El, CO = EI, TW = EI, CH = RHO = RHOS = RS = RT = BT = Zw = Ziu = Zid = Z1 = Zp= Use Zp = Xm = Zp+0.8Zm = EI,PB = 2Lr2 = 2Wr2 = Lru = Lrd = 2Wr= 8/14/2020 1,50 ft 10.29 cfs 0.01 ft/ft 121.12 ft 121.00 ft 121.00 ft 1.00 2.64 0,33 1.00 0,00 2.00 2.00 2.00 2.00 ft ft ft ft/ft ft/ft ft/ft ft/ft 0.12 ft 0.12 ft O.K. 2.77 1.47 119.65 1.16 1.08 3.29 3.29 6.50 O.K. O.K. O.K. ft ft ft ft ft ft ft ft El, BR = 118.65 ft El, BB = 118.65 ft V,pbs = V,rs = A,gt = Spreadsheet developed by D. Hurtz, Midwest NTC, 1/90 Spreadsheet modified by M. Drelschmeler, Eau Claire TC, Wis., 3/98 Design Note No. 6 (Second Edition), Jan. 23, 1986 4.1 cu yd 32 cuyd 19.9 sq yd OLDE MILL STREAM (PHASE 2) CITY OF ROCKY MOUNT, NC 1 36"x36". OUTLET STRUCTURE TOP ELEV= 124' 3.0' RECT. WEIR ELEV= 122.3' INV. IN (6" PVC) = 121.5' INV. OUT (18" RCP) = 121.5' FULL POOL 121.5' 6" PVC CAP WITH 3"0 ----� ORIFICE HOLE DRILLED j POND BOTTOM © ELEV. 118' $ POND BOTTOM WITH 1.0' SEDIMENT CLEANOUT © ELEV. 117' EL. 122.5' TOP ELEV 126' 30' WEIR ELEV 124.3' 38 LF © S=1.0% 18" RCP 6' VEGETATED SHELF (S=6:1) POND Sc RISER SECTION No Scale ANTI -SEEP COLLAR MINIMUM PROJECTION 1.5 FT. OUTSIDE OF PIPE TOP ELEV 126' 1 3 1.O'± FREEBOARD EMERGENCY SPILLWAY ELEV 124.3' 30' 3 TOP ELEV 126' TURF REINFORCEMENT MAT (NORTH AMERICAN GREEN SC-250) EMERGENCY SPILLWAY X-SECTION No Scale PRINCIPAL SPILLWAY USE ONLY APPROVED WATERTIGHT ASSEMBLIES FOR ALL PIPE CONNECTIONS. PLACE BARREL AND RISER ON FIRM, EVEN FOUNDATION, INSTALL ANTI -SEEP COLLAR(S) SLIGHTLY DOWNSTREAM OF DAM CENTERLINE (MINIMUM PROJECTION 1.5 FT.). PLACE MOIST, CLAYEY, WORKABLE SOIL AROUND PIPE AND ANTI -SEEP COLLARS. D0 NOT USE PERVIOUS MATERIAL SUCH AS SAND, GRAVEL, OR SILT. COMPACT 4-INCH LAYERS OF SOIL, BY HAND, UNDER AND AROUND PIPE AND COLLARS TO AT LEAST THE DENSITY OF FOUNDATION SOIL. AVOID RAISING PIPE FROM FIRM CONTACT WITH FOUNDATION WHILE COMPACTING MATERIAL UNDER PIPE HAUNCHES. COVER PIPE TO A DEPTH OF 2 FT. MINIMUM OF HAND -COMPACTED BACKFILL BEFORE CROSSING IT WITH CONSTRUCTION EQUIPMENT. DATE: AUGUST 2020 SCALE(HORZ): AS SHOWN SCALE(VERT): AS SHOWN REVISIONS: Certification by the Department of Development Services that this construction plat was approved by the city planning board on day of 20_. Director of Development Services Certification by the City Engineering Department that this construction plat and required improvement drawings meet the appropriate city standards. Director of Engineering PROJECT: 20-042 CLIENT CODE: RHC CADFILE: 20042CP7 FIELD BOOK: DRAWN BY: RF SURVEY BY: KP, JB ROCKY MOUNT TWNSP NASH COUNTY NORTH CAROLINA ZONE: R-6 & 0-1 PIN # SHEET SCM2 0 0 rei z° n U 0 0 N 0 0 / U ce ce 0 a 1 F CHARGE JOHNSON MITT 247Np0 6% 38301303 A_1 /ONE: LAND) (FARM OUTSIDE CITY U BARTLETT ENGINEERING & SURVEYING, PC 1906 NASH STREET NORTH TELE: (252) 399-0704 WILSON, N.C. 27893-1726 FAX: (252) 399-0804 License No. C-1551 www.bortlett.us.com 4 ++ + DRAINAGE AREA TO SCM Am 011 NY at_ awn errs., „ t%.r1.• i Certification by the Department of Development Services that this construction plat was approved by the city planning board on _ day of Director of Development Services Certification by the City Engineering Department that this construction plat and required Improvement drawings meet the appropriate city standards. Director of Engineering OLDE MILL STREAM CITY OF ROCKY MOUNT, NC 36 + .++ +..nnPF L GRAPHIC SCALE 80 0 40 BO 180 320 DATE: AUGUST 2020 SCALE(HORZ): 1 : 80 SCALE(VERT): N/A REVISIONS: ( IN FEET ) 1 inch = 80 ft. PROJECT: 20-042 CLIENT CODE: RHC CADFILE: 20042CP7 FIELD 800K: DRAWN BY: RF SURVEY BY: KP, JB ROCKY MOUNT TWNSP 15 61 NASH COUNTY NORTH PIN # CAROLINA ZONE: R-6 & 0-1 SHEET SCM3 N 0 0 M z 9 a 0 0 0 0 c O O N U U a O 3 a oI SEDIMENTATION & EROSION CONTROL PLAN PHASE TWO OLDE MILL STREAM Rocky Mount Township Nash County, North Carolina DEVELOPER: HODGE MORRIS, LLC 2101 F. MILLER ROAD WILSON, NC 27893 SHEET INDEX SP1 OVERALL SITE PLAN SE1 SEDIMENTATION & EROSION CONTROL PLAN (PHASE 1) SE2 SEDIMENTATION & EROSION CONTROL PLAN (PHASE 2) SE3 SEDIMENTATION & EROSION CONTROL PLAN (DRAINAGE AREAS) SE4 SEDIMENTATION & EROSION CONTROL PLAN (FINAL PHASE WITH SCM) DT1 DETAILS DT2 DETAILS DT3 DETAILS DT4 DETAILS (NCGO1 GROUND STABILIZATION AND MATERIALS HANDLING) DT5 DETAILS (NCGO1 SELF -INSPECTION, RECORD KEEPING AND REPORTING PREPARED BY: RT BARTLETT ENGINEERING & SURVEYING, PC 1906 NASH STREET NORTH WILSON, NORTH CAROLINA 27893-1726 1 poem siSHAD ICRIEST RIOAD SHADYBROOK COURT MIS 175 173 174 SITE DATA: TOTAL ACREAGE PHASE 1 PHASE 2 TOTAL NUMBER OF LOTS PHASE 1 PHASE 2 ROADWAY IMPERVIOUS PHASE 1 PHASE 2 TOTAL TOTAL BUA LOT 1-61 TOT 62-203 TOTAL OPEN SPACE (LOT 206-207) PROPOSED IMPERVIOUS PHASE 1 PHASE 2 TOTAL PIN NUMBERS 111 sy Stu it 139129PHASE 2127 ® p 128 = 95.3 AC.± = 20.31 AC.± = 38.42 AC.th = 61 (INCLUDING SCM LOT 48) = 142 = 2.42t AC. (105,337t SF) = 4.05t AC. (176.397± SF) = 6.47t AC. (281,734th SF) = 3.25 AC. (141,600t SF) = 9.57 AC. (416.940± SF) = 12.82 AC. (558,540t SF) = 31.2t ACRES (INCLUDING SCM'S) = 5.67 AC. (246,937t SF) (5.95%) = 13.62 AC. (593.337± SF) (14.29%) = 19.23 AC. (840,274t SF) (20.24%) = 383018310386 = 383018311671 NOTES: 208 OPEN SPACE PRIOR TO RECORDING THE FINAL PLAT, THE FOLLOWING ITEMS WILL NEED TO BE SUBMITTED TO THE CITY OF ROCKY MOUNT DEPARTMENT OF ENGINEERING: 1. ENGINEER'S CERTIFICATION, RECORD DRAWINGS, AND TAP CARDS FOR THE PUBLIC SEWER LINES. 2. ENGINEER'S CERTIFICATION, RECORD DRAWINGS, AND SIGNED AND NOTARIZED OPERATION AND MAINTENANCE AGREEMENT FOR THE STORMWATER FACILITIES. 3. ENGINEER'S CERTIFICATION, RECORD DRAWINGS, AND FINAL APPROVAL FROM NCDENR PUBLIC WATER SUPPLY FOR THE PUBLIC WATERLINES. 4. COPY OF RECEIPT FROM NCDENR FOR FINAL SEWER CERTIFICATION MUST BE RECEIVED. 5. PDF COPY OF ALL CORRESPONDENCE RELATED TO WATER AND SEWER PERMIT WITH NCDENR, INCLUDING PLAN SETS AND REVISED PLANS MUST BE CCD TO NEGRETE SILVER ® negrete.silver®rockymountnc.gov (252-972-1127). THIS PLAN IS VALID FOR 2 YEARS FROM DATE OF APPROVAL BY CITY OF ROCKY MOUNT. 198 197 it LOCATION MAP NO SCALE NO ADDITIONS, DELETIONS, CHANGES OR MODIFICATIONS WERE MADE TO THIS PLAN OTHER THAN THOSE REQUESTED BY THE CITY OF ROCKY MOUNT DEVELOPMENT REVIEW COMMITTEE, OTHER THAN LISTED BELOW: REVISIONS: A CRM 2ND REVIEW COMMENTS 10/28/2020 REVISIONS: A CRM 1ST REVIEW COMMENTS 10/13/2020 VICINITY MAP NO SCALE ZONE R-6 ZONE 0-1 46 PHASE 1 ' 10 207 OPEN SPACE ( 49 61 206 OPEN SPACE ZONE R-6 ' ZONE 0-1 1 44. goo _ - h 204 205 Certification by the Department of Development Services that this construction plat was approved by the city planning board on day of 20 . Director of Development Services Certification by the City Engineering Department that this construction plat and required improvement drawings meet the appropriate city standards. 1 1 La I c 1 1 0 0 N 17 N z° 3 r 0 0 0 0 N 0 0 0 0 U Director of Engineering 1/ LOCATION MAP NOT TO SCALE N/F CHARLES & MATTIELEEN JOHNSON DB 947 PG 643 3830130373000 ZONE: A-1 (FARM LAND) OUTSIDE CITY LIMITS N/F HAZEL H. POWELL HEIRS 08 1134 PG 240 P8 19 PG 103 373900092172U ZONE: R-30 (RESIDENTIAL) SITE DATA: TOTAL AREA TOTAL Na OF LOTS T TOTAL UN. FT. OF ST. ZONING BUILDING SETBACKS PROPOSED LAND USE OWNER/DEVELOPER REFERENCE: TAX MAP: ZONE X An0N roo.. FC000 I 1 .+++ + mot + + +_.+ +.{. + + + .+T+�++ *+ I+ + SHADY 48' ZONE AE ROOK CO 27'&B 00. • 04. + , + + OUTSIDE CITY LIMITS + ++'C1�•� • J{ + + + +I+ ++ \ • ++\ + + + + + + 4 + + + +*+*+1 + + + + + + + + + +\+'\••+ :\.. 1+ 0 + N/F PAUL D. WHITLEY, JR. et at DB 972 PG 254 383013139352U ZONE: A-1 (FARM LAND/RESIDENTIAL USAGE) tg ++OPEN.+SPACE,+++ �- ++�+` + ++ + + + *=+�+ +r•i++�+ + + + +F+++++++++++i+ ++++++ + +.. +++++I++++++++++++++ ++ + + + ++++++ **1Fid* ++ + + ++++ ++++++ 1I++A(P O .+ + + ++++I*+ ++++ + +▪ 4. ++++++F4DQpNA'(+ +I++ 40CA7ON++++++ +++ +++ ++ +++«*�++++++ ++I +** + + ++ +' +++ + + + + + + + + + + + + + + +++++ ++ +++ 4 + + + + + ++ ++ I + + + + + + + + + +++ +i +1"++ ++ + + + + ++ + + + + + + ++ �,—r"r_F+-.--+ + * + + + 4 + + + 1I:L+Yl+ ++ ,-. + ++ h+ ++ + + + + *+1++++ + + + ++ +I* + +++f+++ *++++++++++ + + lo *++''+ + + + Ai+i + + + + + ++ + + + + + + + +1 + + ++ + N/F \\- RODNER P. & MAZIE P. HOLLLOMAN DB 1561 PG 305 PB 29 PG 335 383017102255 ZONE: R-30 (RESIDENTIAL) 95.3 ACRES± 203 9,092 LF 0-1 & R-6 FRONT SIDE STREET SIDE REAR SINGLE FAMILY 25' 10' 12.5' 20' HODGE-MORRIS, LLC 1708 TRAWICK RD, STE 209 RALEIGH, NC 27604 DEED BOOK 2162 PAGE 770 3830-18-31-0386 RECORD # 21760 38 0-18-31-1671 RECORD # 21755 + + + + + + + + + + + + + + + +"*+_: N/F JONATHAN 8. WALSTON JENNIFER L. WALSTON DB 2843 PG 991 PB 39 PG 218 373905108577 ZONE: R-30 (RESIDENTIAL) NOTE: AT LEAST ONE (1) LARGE TREE AND ONE (1) SMALL TREE SHALL BE PROVIDED ON ALL SINGLE-FAMILY RESIDENTIAL LOTS. GRAPHIC SCALE 100 0 50 100 200 +{,�+� +++++++ + ++ **NA+ ++ +++ ate+ ++ 4 + + +� + ++++ '+}+ + + + + + + + + + + + +++*+ \ +*+. s;� ++ + + *� + + +++++ + + + + OUTSIDE CITY LIMITS 400 ( IN FEET ) 1 inch = 100 ft. BARTLETT ENGINEERING & SURVEYING, PC 1906 NASH STREET NORTH WILSON, N.C. 27893-1726 License No. C-1551 TELE: (252) 399-0704 FAX: (252) 399-0804 www.bartlett.us.com wdft • • ++i �14+.,`,r++ �..�.. ^+ + + + + + + 3 ++ +++++++'1 ++#. + a4�* + + + +1. + ++ • • • • • • • • • • • • • • NOTE: TEMPORARY ACCESS ROADS SHALL REMAIN IN PLACE UNTIL ANOTHER ACCESS POINT HAS BEEN PROVIDED AND APPROVED BY THE CITY OF ROCKY MOUNT FIRE DEPARTMENT. 1+ + 1++++ +fri ZONE X+++++++! +++*1 • /++ + ++ / • +*+% 1 + + ++ + �' /+ '+++f % + +++ + +++% r++ + %++ ++•/ i \+\+ /+ f+ + + + + + +'i +t ++ '�++++ + +++ + 3 +.,r+-•�+41 + 1 + + + + ++. q�l +++ + ++ ++ +� + +++ ++++*+* + 4 + + + + + ++ \ • • • • • • N/F WINSTEAD FARMS, LLC DB 1835 PG 682 373905199138U 7ONF: R-30 OVERALL SITE PLAN • +'++"+ + + ++\+\ + + +*+++ + ++++t�\+ + +++ 4 + + + + + 1 *++ti + +++++ t +�'* r—•+ +_+ ++++++ ++++++ Q ++ ,.+ +++ + + + r +,+,t+ i/++++++++++++++ +LOCATlot +++ 1 ++ + + +++ + + ++ + 4_I.+,4 4 + + + + + + ++++++++ +++++�+++ + T+ +-tT` +}_++++++ham+ +++++++ ��. A \ + — ++ ++ +++ + ++ +++++++ +/+ r++ '++'+ + +++ + *+ + + + + +++ rim + ../ + ++ +•+ + + +'+ +T+ •may +++ +++ + + p+.{�.• +'c' « +zbwt+12++ +4 + + ++++4 + + + + + + + +++ ++ \ /++ +++*+ + +4. +.,• + + +++++ + + + y r �S.r..1l...�' + +# ++ + .4 + 1 1- .ham .J.+..F' 7I"' + + + +{+++ y + + +C+*+++*+ +*+*++ +++.+++$= +++++ +{1++ +*+ + ++{.+ + + ++ % + +{ `+*+ *+++++++;�+..,..°•r �+ YR F1:40O+++ + +{I++ ++*++ + + + + • +++ ++++++++ +� tOGA110 +100-+ +++++ +++++ + .,+ ..+ --+ + 4t1P,tOX. + t +++ { be++++++*+ +++ + +++ L+ + + *+*+ +++++ + 1 + + + { + + + 1 + i�+1 +++ +•1,++ + ++1 + + + 4 + +++ 1 + +++ + +++++++" + !++�{ ++I + + +++++++++ +++ +�++j t + of ++++ + + + + + + + + + + + + + + I + t:.+=.r . ++ + ..-{.=' .+.-rl..+.' .+= r .x. {. + + + -Fehr''+", + ++++ ++y/+ + + +i++ +++ArPAOX«++ ++jy++ • / / +++206+++*+ ++.PPEN +SP`ACg + { ++ y 3++ + }+ + + %•F + + + + { • O. by the city OUTSIDE CITY LIMITS + + +T+ + + + + + + + + +Y ii +�}`«.+„1++ +++++«++ + ++ + xfr + +\ # + + \+ +ry++1-.x' +t+ ++ih ++I++ ++ + + + 4 +j+"+'+++++ A- +/1/ + )/ + {+ + + +++ �+ + + ++++ +t ++++ ++i++ �� + \++++++ • 14- +++ -_ ++++ + q. ++ + ' • { l'. + + +�>.++++++h//+++{.+++.1*+ *++++ _+ + ?J+*+*+*+ + + I ++I �`+ +1 ++ +\ N/F FAYE P. CAPPS NO REFERENCE 383018302307 ZONE: A-1 (VACANT LOT) 207 OPEN SPACE AT''��P(2'pp0*yy«+++h f00-YW+l11006++++�*+ ++f ++ +1 + I+++i++ 4 + +I++ + +\+ + +/+ + 4 I IN • / / / ▪ / er • 1 1 1 1 fr / / / • 41 1 I ZONE AE \\ Director of Development Services Certification by the City Engineering Department that this conetruction plat and required improvement drawings meet the appropriate city standards. Director of Engineering 205 ZONE X IA eP \\Z Nil ti or wic 4. cc OLDE MILL STREAM (F'HASE 2) CITY OF ROCKY MOUNT, NC DATE: AUGUST 2020 N/A PROJECT: 20-042 CLIENT CODE: RHC FIELD BOOK: DRAWN BY: RF SURVEY BY: KP, JB REVISIONS: CRM 1ST REVIEW COMMENTS 10/13/2020 ROCKY MOUNT TWNSP NASH COUNTY 0 0 NORTH CAROLINA SHEET SP1 a. A • • • • • • • •• \ • • • • • SILT FENCE OUTLET ZONE X '`12 APA . +� 122 %ZUk MCAno_ -- I N N 101 N TM F�90p- • / • / • • / ZONE AE_ 'LIMITS OF DISTURBANCE ++ + oee i •+ + + + + + + + + + + + + + + j + s /•' + + 1+'••., CONSTRUCTION SEQUENCE: • ,. • • • OUTSIDE CITY LIMITS • • • • • • • DEPTH: 2' SPILLWAY LENGTH: 30' SKIMMER SIZE: 4' ORIFICE 2.75' RISER: 3'x3' BARREL: 18' RCP N35.946596 3 W77.879195 `-- "1444,4 +9F + + +916I1i1 RBAt CFI + + + + + + + 1 + + + + + + + + + + + + iN + + • i- 1 + + • SILT FENCE + + +-=i. + + + + + t•- 12Q* _ 4+ + + + + + + + + +. + + + + + +`i + + + + + + + + + t• `• + + + + + + + + + + + + + + + 1. NO WORK TO BE DONE ON SITE UNTIL THE SEDIMENTATION AND EROSION CONTROL PLAN HAS BEEN APPROVED AND PERMIT ACQUIRED. NOTIFY THE CITY OF ROCKY MOUNT OF START DATE, 2. BEGIN WITH THE INSTALLATION OF CONSTRUCTION ENTRANCE AND STREAM CROSSING FOR THE TEMPORARY ACCESS LOCATED AT LOTS 42 & 83. INSTALL SILT FENCE AS NEEDED TO PREVENT MATERIALS FROM GOING INTO THE EXISTING CREEK. 3. INSTALL APPLICABLE E&S CONTROL MEASURES PRIOR TO ONSET OF ANY LAND DISTURBING (INCLUDING DEMOLITION) ACTIVITIES. INSTALL PERIMETER SILT FENCE ACCORDING TO PLANS AND AS NEEDED. 4. CONSTRUCT TEMPORARY SKIMMER BASINS AND SEDIMENT BASIN WITH BAFFLES AND TEMPORARY DIVERSION CHANNELS WITH LINERS AND CHECK DAMS AS SHOWN ON PLANS. EARTH BERMS OF TEMPORARY SKIMMER BASINS AND DIVERSIONS ARE TO BE STABILIZED WHEN BUILT. OUTLET STRUCTURES FOR SKIMMER BASIN#2 AND SEDIMENT BASIN#1 ARE THE SAME STRUCTURES FOR POND#1 AND POND#2 (SEE SHEET SCMI & SCM2). INSTALL 42" RCP LINES "LA2" & "LA3" TO ROUTE STORMWATER FROM TEMPORARY DIVERSION#2 TO THE SKIMMER BASIN#2. INSTALL NECESSARY PIPE INLET PROTECTION 5. BEGIN GRADING AND MAINTAIN DEVICES AS NEEDED. 6. BEGIN INSTALLATION OF UTILITIES AND THE REST OF THE STORM DRAINAGE SYSTEM. INSTALL NECESSARY PIPE INLET PROTECTION. USE PUMP AROUND PRACTICE (SEE CRM DETAILS 3.26 ON SHEET DT3) DURING CONSTRUCTION AT THE SHADYBROOK DRIVE CROSSING. 7. UNTIL BOXES ARE BUILT AND YARD INLET DEVICES INSTALLED, INSTALL AND MAINTAIN PIPE INLET PROTECTION DEVICE FOR STORM DRAIN UNDER CONSTRUCTION AT END OF DAY OR ONSET OF RAIN. 8. INSTALL CATCH BASIN/YARD INLET PROTECTION AFTER BOXES ARE BUILT AND BEFORE CONSTRUCTION OF CURB AND GUTTER. 9. CURB INLET PROTECTION TO BE INSTALLED AFTER GRATES ARE SET OR AS SOON AS CURBS ARE CONSTRUCTED. 10. INSTALL SILT FENCE OVER AND AROUND PIPE OUTLETS. 11. GROUND COVER TO BE ESTABLISHED ON SLOPES OR OTHER AREAS (INCLUDING STOCKPILE AREAS) WITHIN THE GROUND STABILIZATION TIME FRAMES AS SHOWN ON SHEET DT4 FOLLOWING COMPLETION OF ANY PHASE OF GRADING. ANY DISTURBED LOTS AND SPOIL, TOPSOIL, WASTE PILES TO BE STABILIZED, SEEDING TO BE DONE AT RATES AS INDICATED ON PLAN. 12. AFTER GRADING IS COMPLETED, TOPSOIL STOCKPILE.AND WASTE AREAS TO BE REMOVED AND AREA STABILIZED. 13. AFTER ROADWAYS ARE PAVED AND ALL DISTURBED AREAS ARE STABILIZED COMPLETELY, INCLUDING EASEMENTS, LOT IMPROVEMENTS, AND WASTE PILES. REMOVE TEMPORARY MEASURES INCLUDING SKIMMER BASINS#I AND ALL UNSTABLE SEDIMENTS. SMOOTH AREAS TO BLEND WITH ADJOINING AREAS AND STABILIZE PROPERLY. REMOVE ALL TEMPORARY MEASURES ONLY AFTER AN INSPECTION FROM THE LAND QUALITY SECTION AND/OR THE CITY OF ROCKY MOUNT. 14. ALL APPLICABLE E&S CONTROL MEASURES TO BE PROPERLY MAINTAINED UNTIL A VIGOROUS STAND OF PERMANENT VEGETATION IS ESTABLISHED. 15. AFTER UPLAND AREAS HAVE BEEN STABILIZED, REMOVE SEDIMENTS AND CONVERT TEMPORARY SKIMMER BASINS#2 & SEDIMENT BASIN#1 INTO WET PONDS AS SHOWN ON "SCM1" & "SCM2" PLAN SHEETS. 16. STABILIZE SIDE SLOPES WITH PERMANENT VEGETATION AND PROVIDE REQUIRED LANDSCAPE PLANTINGS. #''...T ............ BARTLETT ENGINEERING & SURVEYING, PC 1906 NASH STREET NORTH TELE: (252) 399-0704 WILSON, N.C. 27893-1726 FAX: (252) 399-'0804 License No. C-1551 www.bartlett.us.com SHEET • + •. + +. - \\ + \, \ + • Y • 'N/F s PAlk D. WHITLEY, JR, et al DB 972'FG 254 83013139352U I ZONE: A-1 '---, (FARM"IsAN D/RESIDEN TI AL', 'UF4GE) `. e, • --- 737 N. \ + + \ \ + +'. + + ++ +\., N \\ \..-,^ + + + + + + .., + i\ + \ + +'\ + +"\ + + • \ � \ + +•• \ \ \` ++ • ++\ \\ + +\ t + + + +'� ▪ + h h +• + + a SEDIMENTATION & EROSION CONTROL PLAN (PHASE 1) 1• • • • •\ • • • • • • • • • • • • • • NNIVIISlieRrAstiCt • SILT FENCE • • • SILT FENCE OUTLET glilarR RASIN 1 DEPTH: 2' SPILLWAY LENGTH: 24' SKIMMER SIZE 2.0' ORIFICE: 1.75' BARREL: 4' PVC • • + + i•- +'+ + +! • + + + .11-+-•+ "+, F +`-‘4- + • + + + + + 4 + + . _ ,/, + + + Ni-•-h-.h --(; + + i�- `-•.; - !i.O,j + ,+ + + + + + + + + + + + + + +.. i•+ + +r + + + + -r- T1+ + + t\+ + +, j' + + +� '� ▪ \`\ _ ,11.-- 1'-F' + + 1 �. + •4 + i t_t_ i^-F } + t + + 4/+ + } + + + + + + +\4 + + \+ + +\+ + • .,•' + t + . , _$__+-.�-�_DI#1RSS, NCE__+ + + + /I-`+ + ZoNt+A+ + t + +-q- -OBI-+ + + + + 1 + + + +\+ \ + + +\++ } + �;F + + 4 4 �\\ / / 4'i + + i i + + h + y h + h i,/F i i i i i i i i + + + hr t t�+ + + i + + 4/ i + + i- +1 + + + + +\ +} + �'P�+-. +�+ ` /�/'/� -^ir rl i + + i i /h + + y--4 + + + i + + t + + + + +OFiL \} J h�j ehl` + + i + + + + i t t\+ h •+ + 4 +1+ �4 • �j„WA.° + + + + + + + I\ \ \ \\`\, \•�' % �4 +/+ i + + +-` i--+-• 4" + + +,.+�+ + i + + + i + + + i i + + 4 h L h 1 Y I^ + i_./+ + + } + +I .++\ + + t + \+ i, + ice'+ + SILT FENCE OUTLET ' 11 i 11 1 I 11 1 TEM\D'ORARY CONkTRUCTION ENTRA4CE TEMPORA STREAM CigOSSING \ WITH 2-24 HDPE LIMITS OF DISTURBANCE 44 �\ 45 • i / /// -h, + -- . h '4••..>,! / � / + + + � � + 4 ' C .a - � / / // / / /,i_ +, + + + + T� + + + + .'i^•. / :/+ +-' + + + + + +'moo“�..1 / '+ t SILT FENCE + + ,.t + + + ; -+ + ,+ "T'-,.._.. ;. _ ' i14 +'+ +OUTLET .+�+++++ -T-+h+4$+++/+++ pi- +' + 46 LOCATION MAP NOT TO SCALE DISTURBED AREA ® 41 AC.± EROSION CONTROL LEGEND ELEV ELEV LOD — —SF—SF— zarirgati • 61 DISSIPATOR SUMO BASIN 2 EXISTING CONTOUR PROPOSED CONTOUR UMITS OF DISTURBANCE SILT FENCE CONSTRUCTION ENTRANCE CHECK DAM SILT FENCE OUTLET INLET PROTECTION OUTLET STRUCTURE TEMPORARY DIVERSION TEMPORARY DIVERSION W/ TEMP UNER TEMPORARY SEDIMENT BASIN TEMPORARY CONCRETE WASHOUT AREA ‘\ SPILLWAY LENGTH: 34' \ ORIFICE: 2. RISER: tx3' SKIMMER size. 2.5. t • r. 57 DISTURilkittic7,;. /./ ii , •, ig, , „ 58 • + Certification by the Department of Development Services that this construction plat was approved • + + + + + + I + I+ + I + + + + + by the city planning board on day of 20.. Director of Development Services Certification by the City Engineering Department that this construction plat and required Improvement drawings meet the appropriate city standards. Director of Engineering OLDE MILL STREAM (PHASE 2) CITY OF ROCKY MOUNT, NC DATE. AUGUST 2020 N/A 80 0 40 GRAPHIC SCALE 80 180 320 PROJECT: 20-042 CLIENT CODE: RHC CADFILE: 20042CP7 FIELD BOOK: DRAWN BY: RF SURVEY BY: KP, JB ROCKY MOUNT TWNSP NORTH CAROLINA NASH COUNTY ZONE: R CRM 2ND REVIEW COMMENTS 10/28/2020 CRM 1ST REVIEW COMMENTS 10/13/2020 SHEET SE1 01 CC 7/ ♦ ♦ • • • -' • 139 ' • • • • • • ♦ • 0.44 46.4% deddid SILT FENCE OUTLET ZONE X 12 N. APoRwk--122 , rbr ---�'aN N OD, \fir F ,. 1-QO 12Y. I / iy CONSTRUCTION SEQUENCE: LIMITS OF DISTURBANCE • + + + + r▪ • ▪ .+ + + + + + + + + + ZONE AE +++ + ++ + + - , + + •13 • • • • OUTSIDE CITY LIMITS DEPTH: 2' SPILLWAY LENGTH: 30' SKIMMER SIZE: 4' ORIFICE: 2.75' RISER: 3'x3' BARREL: iB' RCP I \ ~ min+QIi+++.4.+t4P-_+++t+++�+ i-a *DIS11URBA1jCF�+ + +--12Dk_ + +"+'•__`'- - + + + + + + + t + + t '\ • \ \ \ .01 + + h-+�^i• t t i i + + + +\• \ SILT FENCE ♦ N. ♦ Tt/F PAUL♦ D. WHITTLEY, JR, et al bB 972'EG 254 y58301313$352U I ZONE: A-1 ---, (FARM\*AN D /RESIDENTIAL Wi3GE) ♦ a• ♦r37. . 1. NO WORK TO BE DONE ON SITE UNTIL THE SEDIMENTATION AND EROSION CONTROL PLAN HAS BEEN APPROVED AND PERMIT ACQUIRED. NOTIFY THE CITY OF ROCKY MOUNT OF START DATE, 2. BEGIN WITH THE INSTALLATION OF CONSTRUCTION ENTRANCE AND STREAM CROSSING FOR THE TEMPORARY ACCESS LOCATED AT LOTS 42 & 83. INSTALL SILT FENCE AS NEEDED TO PREVENT MATERIALS FROM GOING INTO THE EXISTING CREEK. 3. INSTALL APPLICABLE E&S CONTROL MEASURES PRIOR TO ONSET OF ANY LAND DISTURBING (INCLUDING DEMOLITION) ACTIVITIES. INSTALL PERIMETER SILT FENCE ACCORDING TO PLANS AND AS NEEDED. 4. CONSTRUCT TEMPORARY SKIMMER BASINS AND SEDIMENT BASIN WITH BAFFLES AND TEMPORARY DIVERSION CHANNELS WITH LINERS AND CHECK DAMS AS SHOWN ON PLANS. EARTH BERMS OF TEMPORARY SKIMMER BASINS AND DIVERSIONS ARE TO BE STABIUZED WHEN BUILT. OUTLET STRUCTURES FOR SKIMMER BASIN#2 AND SEDIMENT BASIN#1 ARE THE SAME STRUCTURES FOR POND#1 AND POND#2 (SEE SHEET SCM1 & SCM2). INSTALL 42" RCP LINES "LA2" & "LA3" TO ROUTE STORMWATER FROM TEMPORARY DIVERSION#2 TO THE SKIMMER BASIN#2. INSTALL NECESSARY PIPE INLET PROTECTION 5. BEGIN GRADING AND MAINTAIN DEVICES AS NEEDED. 8. BEGIN INSTALLATION OF UTILITIES AND THE REST OF THE STORM DRAINAGE SYSTEM. INSTALL NECESSARY PIPE INLET PROTEC11ON. USE PUMP AROUND PRACTICE (SEE CRM DETAILS 3.26 ON SHEET DT3) DURING CONSTRUCTION AT THE SHADYBROOK DRIVE CROSSING. 7. UNTIL BOXES ARE BUILT AND YARD INLET DEVICES INSTALLED, INSTALL AND MAINTAIN PIPE INLET PROTECTION DEVICE FOR STORM DRAIN UNDER CONSTRUCTION AT END OF DAY OR ONSET OF RAIN. 8. INSTALL CATCH BASIN/YARD INLET PROTECTION AFTER BOXES ARE BUILT AND BEFORE CONSTRUCTION OF CURB AND GUTTER. 9. CURB INLET PROTECTION TO BE INSTALLED AFTER GRATES ARE SET OR AS SOON AS CURBS ARE CONSTRUCTED. 10. INSTALL SILT FENCE OVER AND AROUND PIPE OUTLETS. 11. GROUND COVER TO BE ESTABLISHED ON SLOPES OR OTHER AREAS (INCLUDING STOCKPILE AREAS) WITHIN THE GROUND STABILIZATION 11ME FRAMES AS SHOWN ON SHEET DT4 FOLLOWING COMPLETION OF ANY PHASE OF GRADING. ANY DISTURBED LOTS AND SPOIL, TOPSOIL, WASTE PILES TO BE STABIUZED. SEEDING TO BE DONE AT RATES AS INDICATED ON PLAN. 12. AFTER GRADING IS COMPLETED, TOPSOIL STOCKPILE AND WASTE AREAS TO BE REMOVED AND AREA STABIUZED. 13. AFTER ROADWAYS ARE PAVED AND ALL DISTURBED AREAS ARE STABILIZED COMPLETELY, INCLUDING EASEMENTS, LOT IMPROVEMENTS, AND WASTE PILES. REMOVE TEMPORARY MEASURES INCLUDING SKIMMER BASINS#1 AND ALL UNSTABLE SEDIMENTS. SMOOTH AREAS TO BLEND WITH ADJOINING AREAS AND STABILIZE PROPERLY. REMOVE ALL TEMPORARY MEASURES ONLY AFTER AN INSPECTION FROM THE LAND QUALITY SECTION AND/OR THE CITYOFROCKY MOUNT. 14. ALL APPLICABLE E&S CONTROL MEASURES TO BE PROPERLY MAINTAINED UNTIL A VIGOROUS STAND OF PERMANENT VEGETATION IS ESTABLISHED. 15. AFTER UPLAND AREAS HAVE BEEN STABILIZED, REMOVE SEDIMENTS AND CONVERT TEMPORARY SKIMMER BASINS#2 & SEDIMENT BASIN#1 INTO WET PONDS AS SHOWN ON SHEET "SCM1" & "SCM2" PLAN SHEETS. 18. STABILIZE SIDE SLOPES WITH PERMANENT VEGETATION AND PROVIDE REQUIRED LANDSCAPE PLANTINGS. BARTLETi" ENGINEERING & SURVEYING, PC 1906 NASH STREET NORTH TELE: (252) 399-0704 WILSON, N.C. 27893-1726 FAX: (252) 399-0804 License No. C-1551 www.bartlett.us.com +•• \\ \ • + + • + • + + + + + +\ + +++++' �� ++++++++++ + +\'•\ \\44 + + + + + +•. +i + i ++++++ h+•\ \\ ` \ SEDIMENTATION & EROSION CONTROL PLAN (PHASE 2) A • • • ♦ *++++++ \ �! ♦♦♦ • • • + + + + N. • + + + + /\ • • + + + +\\ + + + • / • ♦ ZONE X • \ LIMITS OF-. DISTURBANCE \ \ \, ♦ +�++`\, \\\ SILT FENCE OUTLET + + \ • + + + -4 + + <- - + + + + + t i + +/ • + + f•"r-•i-:, k/+ L + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + • ♦ • • _ SILT FENCE OUTLET SafilUt BASIN 1 DEPTH: 2' SPILLWAY LENGTH: 24' SKIMMER SIZE: 2.0' ORIFICE: 1.75' BARREL: 4' PVC • • • ✓ / -+--.t • •_ / r + + + +\�. i-'' / �•"' i i' +/'+ + + + 4� + + + + ••i^••�...... / / i :�+ +♦ + + + + + + :r••- / -••0+ i;SILT FENCE + +`\t + + + +.--+ + ,+ �•�..-..r s ; + + r•-,+ +�.+ + }.-+ + + + +"�••..., +• ' +.a+ + OUTLET .*, + + +-.4,-+ , + +/+ + ,4- + + TE ORARY CON IBUCTION ENTRNCE Silk FENCE • C O TEMPORA Y STREAM SSING WITH 2-24 \HDPE . LIMITS OF k ` • DISTURBANCE \\ \\\ :4 _-+ + + + + + + -+--ram---F + + .'F + + /4 + + + + j• + j/ + + * + + + + + + + + + + + + +__+/+ + + ,h + + + + + •44 + 4 + + / 4 + + „ #- 44 + 'i^ -•t i i +. _• .444 + + + +.4 + + + + + OF +-+•�+++� �/ + + wtortiRtANdE + + + + + + + + + + + 4i'+ + Zul4�+ \♦ \♦ /. .+' + i 1 + + + + + + + j. + + + +.4- + ♦ /�//+ + I--9'�k + + + + + +.h + + j.--.4"-+ + + \ ', * +/+ + + + +>"+-+41-'+ + +,.+-1h + + + + \ \ •"• , .J +/+ + t + + + + + + t-'F'+ + + + + + +. \\\ /F. i'' + + + +I\+ + + + +..+'+ + + + + + + + + + /' +_.*.F\ + + ir-•+ + + + + + + + + + + + + c9f'-+�"9+ +'+ +�h + /+ + + -+- + + + + +, + + + + + + + + + +♦ ' + µ + Certification by the Department of Development Services that this by the city planning board on _ day of 20_. construction plat was approved Director of Development Services Certification by the City Engineering Department that this construction plat and required improvement drawings meet the appropriate city standards. Director of Engineering OLDE MILL STREAM (PHASE 2) a- CITY OF ROCKY MOUNT, NC DATE: AUGUST 2020 SCALE(VERT): N/A 80 0 40 LOCATION MAP NOT TO SCALE IDISTURBED AREA = 41 AC.± EROSION CONTROL LEGEND ELEV EXISTING CONTOUR ELEV PROPOSED CONTOUR - LOD- LIMITS OF DISTURBANCE - SF-SF- SILT FENCE c CONSTRUCTION ENTRANCE CHECK DAM SILT FENCE OUTLET INLET PROTECTION OUTLET STRUCTURE TEMPORARY DIVERSION TEMPORARY DIVERSION W/ TEMP LINER TEMPORARY SEDIMENT BASIN TEMPORARY CONCRETE WASHOUT AREA DISSIPALOR 60 DEPTH: 2' SPILLWAY LENGTH: 34' SKIMMER SIZE: 2.5. ORIFICE: 2* RISER: rxr BARREL: 24. RCP GRAPHIC SCALE 80 180 • aivikok 55 320 PROJECT: 20-042 CLIENT CODE: RHC FIELD BOOK: DRAWN BY: RF SURVEY BY: KPI J8 1 inch = 80 ft. ROCKY MOUNT TWNSP NASH COUNTY 11:23AM EST ter 0 14-1 444 .419 NORTH CAROLINA REVISIONS: CRM 1ST REVIEW COMMENTS 10/13/2020 SHEET SE2 CC CL I / • • •\ \ • • • • • • • • • SILT FENCE OUTLET \ ZONE X APc +� '� --/zz847 �j0AnOti \- ..4. 1pp',pi. • • • • '72 / y. 00°- —138— / / --LIMITS OF DISTURBANCE /;.F—+" :+++++++++ ++++++ + ZONE AE +++ + BARTLETT \ OUTSIDE CITY LIMITS • • • • • • • DEPTH: 2' SPILLWAY LENGTH: 30' SKIMMER SIZE 4" ORIFICE 2.75" RISER: 3'x3' BARREL: 18" RCP ENGINEERING & SURVEYING, PC 1906 NASH STREET NORTH WILSON, N.C. 27893-1726 License No. C-1551 I N. \ ..• \ 7z, ,Tr§,9F +'ram + + + + b-f DISTURBAI G+ + +�•-12a+_t + + + �: + ++ ++++}+�-t++a. 1� +I+ + + + + + + + + + + + +—+-w �, + + + + + + + + + + + + + + + \-..- + + + + + + + + + + + \ � + + +•. IN SILT FENCE N + + "4 + I + TELE: (252) 399-0704 FAX: (252) 399-0804 www.bartlett.us.com + + + +\.• + + + + \ \ + + + +•\ \ \ + + '\ + + + •. + + +\., \ + + + +P•'Y•• ..�.. + + + + + + •'1\ • + + + + + 1\ + + + + + +\. \\ + + + + + •1\ \ \ • + + + + + +•\ \ \\ \ L + + + + }. + + + + •\ + + } + '. + + + +\. + + + }N. + + + + N. \\ `\ 'N/ F PAUL\ D. WHITLEY, JR. et al \DS 972 \QG 254 83013139352U \ ZONE: A-1 -, (FARM\JkAND/RESIDENTIAL\\ 'LIF4GE) • -• • • • T • ++++\ + + + +\ • \ ZQ\N• E X + + + 'V \\ +++ y + + A\ \\ + +'\ \ +•\ \ 1 / \\ N ` • • -\ LIMITS DISTURBANCt \ SILT FENCE OUTLET ------_. + +\t 1 + -•+\+ + • SILT FENCE OUTLET FR RASIN 1 DEPTH: 2' SPILLWAY LENGTH: 24' SKIMMER SIZE: 2.0" ORIFICE: 1.75" BARREL: 4" PVC + .+ t + + + \+ + + + + •+ _+ + + + + Certification by the Department of Development Services that this construction plat was approved by the city planning board on _ day of 20_. Director of Development Services Certification by the City Engineering Department that this construction plat and required Improvement drawings meet the appropriate city standards. Director of Engineering SEDIMENTATION & EROSION CONTROL PLAN (DRAINAGE AREAS) +•+ + .+ + r\ • ORARY CON \TRUCTION ENTRANCE `\\ SIL\� FENCE • TEMPORA Y �- STREAM C OSSING "�� \\\ WITH 2-24 \ HDPE �` • LIMITS OF �\ • DISTURBANCE \\ \ \\\ \\ es #, !F +�++\ +++-h\`• +,'+ + +\� + +ct._ . / ' / /,% + + + + + + + + + ••i'-••_. +\ + + + + + + iF•"+.. // ;SILT FENCE + +`\t + + + + '+ + '• ,•.,.._„r + + + + t + $.. + + h + • • , • • - + OUTLET \ + + + t t + +/+ + ,+ + + •., + -+' + + r T r r r -r + + + + t_-_+ + � + + + + + - + '+ +-r-f"+ + + + + + .r--r-r--F + + .4 + + f + + + + + +- . -041---:ye. + + + y: + + + + + + + + + + + +,h + + + + + +'+ + Optoe ++_f� t t+++++++ t++++s+ht+� 1.h*it)+j.ha*j'++4'i4iQ1SpJRBAIVG\E,++h+++fit'+++. + +'F-P-i�}/+ \i \ •\ `• /�%/( . -t-Tom'{{. 1. 1. + + + + + + + i\ \• ,/ % A- +/+ + + + �—+— + + + + + + + .9"\,^_ \ \• •- ,i• / +/+ + ,+ + + + + +y+y+ +1+y+11+'1�„� �.1 \\\\ ...•�"r r+1+�+1+yt\\+ + + + • • OLDE MILL STREAM (PHASE 2) CITY OF ROCKY MOUNT, NC DATE. AUGUST 2020 REVISIONS: N/A 80 40 LOCATION MAP NOT TO SCALE DISTURBED AREA a 41 AC.± EROSION CONTROL LEGEND ELEV ELEV -LOD- —SF—SF— t1 •ZC .17.00 61 DISSIPATOR PAD "LC" 60 EXISTING CONTOUR PROPOSED CONTOUR LIMITS OF DISTURBANCE SILT FENCE CONSTRUCTION ENTRANCE CHECK DAM SILT FENCE OUTLET INLET PROTECTION OUTLET STRUCTURE TEMPORARY DIVERSION TEMPORARY DIVERSION W/ TEMP UNER TEMPORARY SEDIMENT BASIN • SPILLWAY LENGTH: \ ORIFICE: 2" BARREL: 24" RCP GRAPHIC SCALE 80 160 k \:' 1 / lit ai iff 320 PROJECT: 20-042 CLIENT CODE: RHC CADFILE: 20042CP7 FIELD BOOK: DRAWN BY: RF SURVEY BY: KP, JB ROCKY MOUNT TWNSP NASH COUNTY 0 0 441* 0 0 0 CC ce a. NORTH CAROLINA SHEET SE3 co • • • - _- • • • • • • • • • • `\ • • • \ SILT FENCE OUTLET ZONE X 41'ft? �OAnON --� N A. r00�yR ru, ' 1 —.- D / i SITE NOTES: ALL WORK SHALL CONFORM TO THE CITY OF ROCKY MOUNT'S LAND DEVELOPMENT CODE AND THE MANUAL OF SPECIFICATIONS AND DETAILS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK ZONE TRAFFIC CONTROL IN OR ADJACENT TO NCDOT OR CITY RIGHT OF —WAY. ALL METHODS SHALL CONFORM TO THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) AND NCDOT STANDARDS. CONTRACTOR TO COORDINATE INSTALLATION OF CONDUITS FOR PHONES & UGHTING. PRIMARY ELECTRIC LINES AND RELATED FACIUTIES SHALL BE INSTALLED 10—FT BEHIND THE CURB/EDGE OF PAVEMENT AT A DEPTH OF NO LESS THAN 48 INCHES OF FINISHED GRADE. CONTACT DARRYL STROTHER (252 467-4808) TO COORDINATE THE PROPOSED ELECTRIC INSTALLATION ROUTE. UNUSABLE EXCAVATED MATERIALS AND ALL WASTE RESULTING FROM CLEARING AND GRUBBING SHALL BE DISPOSED OF AT AN APPROVED PERMITTED OFF —SITE LOCATION BY CONTRACTOR. ASPHALT PAVING TO BE A MINIMUM OF 8" CABC AND 2" SF9.5A. CONTRACTOR RESPONSIBLE FOR COMPLYING WITH ALL REQUIREMENTS/ CONDITIONS OF ALL ENCROACHMENTS & PERMITS INCLUDING PROVIDING BONDS/INSURANCE IF REQUIRED. CONTRACTOR IS RESPONSIBLE FOR COORDINATING REQUIRED INSPECTIONS. CALL ONE CALL CENTER AT 1-800-632-4949 FOR LOCATIONS OF EXISTING UTILITIES 48 HOURS MINIMUM PRIOR TO EXCAVATION. ZONE AE i /• F. IF • • \ ` / OUTSIDE CITY LIMITS • • • • • • • • • • • `\ • 44444. 07+ + +i•.+ + + + + + + + + + + + + + + + + + +� 7 / / 7 7 LIMITS OF DISTURBANCE „�.. !•+ + + + + + + + + �i'+ + + + + + ++++++ + + + + + + + + +N EXCAVATION AND GRADING PI AN NOTES: ALL AREAS NOT COVERED BY PAVING TO BE GRASSED, LANDSCAPED OR LEFT NATURAL AS INDICATED. CONTRACTOR SHALL NOTIFY AND COOPERATE WITH ALL UTILITY COMPANIES OR FIRMS HAVING FACIUTIES ON OR ADJACENT TO THE SITE BEFORE DISTURBING, ALTERING, REMOVING, RELOCATING, ADJUSTING OR CONNECTING TO SAID FACIUTIES. CONTRACTOR SHALL RAISE OR LOWER TOPS OF EXISTING MANHOLES AS REQUIRED TO MATCH FINISHED GRADES. BEFORE ANY MACHINE WORK I5 DONE, CONTRACTOR SHALL STAKE OUT AND MARK ITEMS ESTABLISHED BY THE SITE PLAN. CONTROL POINTS SHALL BE PRESERVED AT ALL TIMES DURING THE COURSE OF THE PROJECT. LACK OF THE PROPER WORKING POINTS AND GRADE STAKES MAY REQUIRE CESSATION OF OPERATIONS UNTIL SUCH POINTS AND GRADES HAVE BEEN REPLACED TO THE OWNERS SATISFACTION. EXISTING CONDITIONS: THE CONTRACTOR SHALL BE RESPONSIBLE FOR REVIEWING ALL EXISTING JOB CONDITIONS. ANY ADVERSE CONDITIONS AFFECTING WORK SHOWN ON THESE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR POSSIBLE CLARIFICATION OR RECONCILIATION. CONSTRUCTION SAFETY: THESE DRAWINGS DO NOT CONTAIN THE REQUIREMENTS FOR JOB SAFETY. ALL PROVISIONS FOR SAFETY SHALL BE SOLE RESPONSIBILITY OF THE CONTRACTOR. STQjkill IRAI FILL: SEE SPECIFICATIONS FOR STRUCTURAL FILL INFORMATION. OFFSITE BORROW / TRENCH BORROW: BARTLETT ENGINEERING & SURVEYING, PC 1906 NASH STREET NORTH WILSON, N.C. 27893-1726 License No. C-1551 SILT FENCE *\\—- �� + ••\ \ s. + \. \ \ + \, \ + +•\ OFFSITE BORROW MATERIAL PLACED ON SITE SHOULD BE LOW PLASTICITY (PI LESS THAN 25 AND LL LESS THAN 50) AND SHALL BE FREE OF ORGANIC MATERIAL OR DEBRIS PLACE FILL IN 8" TO 10" LOOSE LIFTS AND COMPACT TO 95% OF THE STANDARD PROCTOR MAXIMUM DRY DENSITY, ASTM D698. THE MOISTURE CONTENT OF THE SOIL SHOULD BE MAINTAINED WITHIN t 3 PERCENTAGE POINTS OF THE OPTIMUM MOISTURE CONTENT DETERMINED BY THE SAME TEST. OFF —SITE BORROW MATERIAL TO BE OBTAINED FROM A PERMITTED SOURCE. ADA AND LEGAL DISCLAIMER: THIS DOCUMENT IS NOT REPRESENTED TO COMPLY W1TH ALL REQUIREMENTS CONTAINED IN THE ADA OR OTHER LAWS. ENGINEERS ARE NOT LICENSED TO INTERPRET LAWS OR GIVE ADVICE CONCERNING LAWS, THE OWNER SHOULD HAVE THIS DOCUMENT REVIEWED BY HIS ATTORNEY TO DETERMINE LEGAL COMPLIANCE. DISCLAIMER: THE UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND EXISTING DRAWINGS. THE SURVEYOR MAKES NO GUARANTEE THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN HE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED ALTHOUGH HE DOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM INFORMATION AVAILABLE. THE SURVEYOR HAS NOT PHYSICALLY LOCATED THE UNDERGROUND UTILITIES. TELE: (252) 399-0704 FAX: (252) 399-0804 www.bartlett.us.com SEDIMENTATION & EROSION CONTROL PLAN (WITH SCM S) PAU'b D. WHI EY, JR. et - al- -------- DD8 972 `EG 254 83013139352U I ZONE: A-1 '---. (FARM\*AN D/RESIDENTIAL\\ 'USAGE) \\\ +++1\ \ \ • + +\, + +'\ \:«\ + +• + # + + \+ + + +, + + + +. � •-! \ •\ + + + + N. • • • • • + + + +\, \ • ZONE X + + fi/ \\ + + r \ \ \ ++6\• ` •\\ • • it + + + + \ \ \ OUTLET + r • • • \ • • • ``\LIMITS DISTURBANCt \ \ \ SILT FENCE t +'\+++ h` • • • SILT FENCE OUTLET • + + + \ram-.ram_.-_�.+ + +�+1., • • `— . SILT FENCE OUTLET 1 1 1 11 II 1 1 i 111• I 111 i 1 11 II 1 11 11 TElk\ORARY CON&?RUCTION ENTRANCE \\\ SILT FENCE • TEMPORA Y `` \ STREAM CROSSING � \\ WITH 2-24 \\ HDPE DISTURBAKE • +" + �,. ; i + „++ + r +\, + + + + + -- • + + + �r + + + + + + + + + + + + ,iR• +4 + +,•4 + + A•• i + T- -A.. _ _ i' SILT FENCE + + `t + + + +. + + /+ •T• •-,.._, • + + + + + �+ + + OUTLET + + + �- + +,-� t +/+ + ,( + + � r tom+ + .—+ + + + + + + + + + + + + + + + +\ + + +\ �.... i • • Certification by the Department of Development Services that this construction plat was approved by the city planning board on day of 20 Director of Development Services Certification by the City Engineering Department that this construction plat and required improvement drawings meet the appropriate city standards. Director of Engineering OLDE MILL STREAM (PHASE 2) CITY OF ROCKY MOUNT, NC DATE: AUGUST 2020 i✓+ + .r + + + + /4 + + + + + h + + + +/ { + + + + + + +/ + + REVISIONS: N/A PROJECT: 20-042 CLIENT CODE: RHC FIELD BOOK: DRAWN BY: RF SURVEY BY: KP, JB LOD SF LOCATION MAP NOT TO SCALE EROSION CONTROL LEGEND ELEV ELEV nip 1 61 DISSIPATOR 60 • • SKIMMER SUE: 25' ORIFICE: 2" RISER: tx3. BARREL: 24" RCP • 58 EXISTING CONTOUR PROPOSED CONTOUR LIMITS OF DISTURBANCE SILT FENCE CONSTRUCTION ENTRANCE CHECK DAM SILT FENCE OUTLET INLET PROTECTION OUTLET STRUCTURE TEMPORARY DIVERSION TEMPORARY DIVERSION W/ TEMP LINER TEMPORARY SEDIMENT BASIN if 57 • tr • GRAPHIC SCALE ROCKY MOUNT TWNSP NORTH CAROLINA • 55 NASH COUNTY ZONE: 8c 0-1 SHEET SE4 til acC re re 0 61 DISSIPATOR 60 • • SKIMMER SUE: 25' ORIFICE: 2" RISER: tx3. BARREL: 24" RCP • 58 EXISTING CONTOUR PROPOSED CONTOUR LIMITS OF DISTURBANCE SILT FENCE CONSTRUCTION ENTRANCE CHECK DAM SILT FENCE OUTLET INLET PROTECTION OUTLET STRUCTURE TEMPORARY DIVERSION TEMPORARY DIVERSION W/ TEMP LINER TEMPORARY SEDIMENT BASIN if 57 • tr • GRAPHIC SCALE ROCKY MOUNT TWNSP NORTH CAROLINA • 55 NASH COUNTY ZONE: 8c 0-1 SHEET SE4 til acC re re 0 PROVIDE HIGH STRENGTH DOUBLE STITCHED J TYPE SEAMS HEAVY DUTY DIRTBAG 55 OR EQUAL 15' AGGREGATE UND RLAYMENT 10"THICK NCD OT 0 ?STONE) SEWN IN SPOUT HIGH STRENGTH STRAPPING FOR HOLDING HOSE IN PLACE WATER FLOW FROM PUMP OPENING TO ACCOMODATE UP TO 4" DISCHARGE HOSE NOTES: 1. THE DEWATERING BAG SHALL BE MADE OF NONWOVEN GEOTEXTILE WITH A MIN. SURFACE AREA OF 225 SQUARE FEET PER SIDE. 2. ALL STRUCTURAL SEAMS SHALL BE SEWN WITH A DOUBLE STITCH USING A DOUBLE NEEDLE MACHINE WITH HIGH STRENGTH THREAD. 3. THE SEAM STRENGTH SHALL WITHSTAND 100 LBSN USING ASTM D4884 TEST METHOD. 4, THE GEOTEXTILE FABRIC SHALL BE A 100Z NONWOVEN FABRIC. 5. DISCHARGE FROM THE DEWATERING BAG SHALL BE DIRECTED SUCH THAT PRE -DISTURBANCE HYDROLOGY 19 NOT CHANGED. DEWATERING BAG REVISIONS NO DATEDESCRIPTION CITY OF ROCKY MOUNT DEPT. OF ENGINEERING HAY BALES ARE NOT AN ACCEPTABLE ALTERNATIVE TO SILT FENCING. TOP AND BOTTOM STRAND "/_. SHALL BE 10 GAUGE MIN. NOTES: WIRE SHALL BE A MINIMUM Or 32' IN WIDTH AND SHALL HAVE A MINIMUM OF 6 I.HIEWIRES WITH 12' STAY SPACING. FILTER FABRIC SHALL BE A I1IIIINUM OF 36' IN WIDTH, SHALL NEET THE REQUIRE- MENTS OF NC DOT SSRS SECTION 1056 FOR TYPE 3, CLASS A FILTER FABRIC. AND SHALL BE FASTENED ADEQUATELY TO THE WIRE AS DIRECTED BY THE ENGINEER STEEL POST SHALL DE 5'-0' IN HEIGHT AND DE OF THE SELr-FASTNER ANGLE STEEL YPE. WOOD POST SILT FENCE IS NOT AN ACCEPTABLE ALTERNATIVE. :niu wlBwmw-L- WIRE SYMBOL APPROVED STD. NO. 3.25 DATE 02-26-10 6 LAX exIRA 3140.1c1., 0111111( WflICUR um( mice MIDDLE AND VERTICAL. WIRES SHALL BE 12 1/2 GAUGE MIN FILTER FABRIC 8' DOWN E 4" FORWARD ALONG THE TRENCH FILTER FABRIC CONIPACTED FILL UPSLOPE TI 4 MIN. --- REVISION Ada FILTER FABRIC Ili �14113 -24" .I I Mall II II 1111 crT -NCI I"NI=III"iii"IT1: 24' WIRE STEEL POST _11111 I( EXTENS ON OF FABRIC AND WIRE INTO FABRIC TEMPORARY SEDIMENT (SILT) FENCE REVISIONS Nn PATF PFSrRIPTInN :I'p ..RCcn0 CITY OF KICKY MCUNJ DEPT OF ENGINEERING STEEL FENCE POST WIRE FENCE HARDWARE CLOTH FILTER OF 1 INCH DIAMETER # 57 WASHED STONE FILTER OF 1 INCH DIAMETER # 57 WASHED STONE NOM SILT SILT FENCE FABRIC TO OVERLAP HARDWARE CLOTH BY 12 INCHES SILT FENCE FABRIC SIDE VIEW SILT FENCE FABRIC ON WRE FENCE HARDWARE CLOTH FRONT VIEW 18 6" GRADE MAINTENANCE: APPROVED STD. NO. 3.3 DATE 06-26-07 INSPECT SEDIMENT FENCE OUTLET AT LEAST ONCE A WEEK OR AFTER EACH RAINFALL MAKE ANY REQUIRED REPAIRS IMMEDIATLELY. SHOULD THE FABRIC OF A SEDIMENT FENCE COLLAPSE, TEAR, DECOMPOSE OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. REMOVE SEDIMENT AND RESTORE IRE SEDIMENT STORAGE AREA DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN. RESTORE OR REPLACE STONES AS NECESSARY. REMOVE ALL FENCING MATERIAL AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. SEDIMENT STORAGE HARDWARE CLOTH ON WIRE FENCE PLAN VIEW STEEL FENCE POST SET MAXIMUM 2 FEET APART HUE; BURY WIRE FENCE, HARDWARE CLOTH, AND SILT FENCE FABRIC 8 INCHES INTO. THE TRENCH STEEL FENCE POST WIRE FENCE 11=11 1-11=11=11=1111=Ildlldll-ll= n...4 II- =T1= -TI I STANDARD SILT FENCE OUTLET NO SCALE REVISION BARTLETT ENGINEERING & SURVEYING, PC 1906 NASH STREET NORTH WI LSON, N.C. 27893-1726 License No. C-1551 'r>;NTIENS '.;rERF v IaCIILL L DESIGN. CRI TC.F.n ,....c..,., .,n I la r:J' )1IN. tt-k to. al ttata t 91 N. I.: \(1iILIiRAII. I.1eV-1:" n.A dttA VI wanly III I1.A11 GRAVEL CONSTRUCTION ENTRANCE CITY OF ROCKY MOUNT DEPT. OF' ENGINEERING APPROVED STD. NO. 3.17 DATE 09-22-2010 REVISION EMI , esr'6° ✓T :27 Ars P rr«rr� J II.II�I. IIIL=1111-ati=1 I/-U I=�j',freer U111111 _-r=u=n = TI_r=1�11=11�= r=111=1I11- TERMINUS DETAIL A NOTE BURY THE TOP END OF THE MATTING STRIPS IN A TRENCH a 4 OR MORE IN DEPTH, a m tt las TERMINUS DETAIL C 44 TERMINUS DETAIL B NOTE. TARP THE TRENCH FULL OF SOIL. SECURE WITH A ROW OF STAPLES, 10' yyy SPACING, 4' DOWN FROM THE TRENCH. • rm�y MAW _ 1 r- " ro"-" /- 44 Jib 1111=1L_Ih1LI=L11=Ill=11)i=III .Ip=I1�=1111 -n=rn=n-r=r= ITiI_iil =�i-I =III =r NOTE' OVERLAP - BURY UPPER END OF Ov LOVER STRIP AS IN 'A' AND 'Be. ..�_ OVERLAP END OF TOP STRIP ID' AND STAPLC, A 1r_. _r r - :77 1111=1m-(L(// II-1111-)III-110111r1 414 I11=jjp-I - I -L =_n=n=r1=11=r=11r1=u=n )III?. =1�fLI =r_��� �IIJ'= =n=lrll= �I( I=_ 44 'fi•'4.4"•„h' =j iv. ir /,•A1/�jlj�_. fps%caf.. .. r/ .���t g riff•e fjae rl thrtte rroir,, Ja/--srr a TERMINUS DETAIL D NOTE. EROSION STOP - FOLD OF MATTING BURIED IN SLIT TRENCH AND AND TAMPED WITH DOUBLE ROW OF STAPLES. IA CHANNEL STABILIZATION W/EROSION MATTING (SHEET 2 OF 3) REVISIONS NO DATE DESCRIPTION 114' WIRE MESH A L MAXIMUM POST SPACING 4 FT. SEDIMENT CONTROL STONE FILTERED WATER SECTION A -A CITY OF ROCKY MOUNT DEPT. OF ENGINEERING A j AVERAGE BOX DIMENSION VARIABLE MULTI -DIRECTIONAL FLOW SYMBOL NOTE SEDIMENT CONTROL STONE SHALL BE NO. 5 OR NO, 57. WIRE MESH SHALL BE HARDWARE CLOTH 23 GAUGE MIN AND SHALL HAVE 1/4' INCH MESH OPENINGS. TOP OF WIRE MESH SHALL BE A MINIMUM OF ONE FOOT BELOW THE SHOULDER OR ANY DIVERSION POINT. STEEL POST SHALL DE 5 FT, IN HEIGHT, BE INSTALLED 1,5 FT. DEEP MINIMUM, AND BE OF THE SELF -FASTENER ANGLE STEEL TYPE. WORD POST SHALL BE 6 FT. IN HEIGHT, BE INSTALLED TO 1.5 FT. DEEP MINIMUM, AND BE 3 INCHES IN DIAMETER. POST SPACING SHALL BE A MAXIMUM OF 4 ET, fay. SED CONTROL STONE APPROVED STD. NO. 3.13 DATE 04-10-00 Y 1/4' WIRE MESH BEE NOTE FOR POST DESCRIPTION FILTERED WATER SECTION Y-Y FLOW AVERAGE BOX DIMENSION VARIABLE SINGLE -DIRECTIONAL FLOW REVISION ROCK INLET SEDIMENT TRAP TYPE IC' Nn DATE REVISIONS ITFSCRTPTVIN TELE: (252) 399-0704 FAX: (252) 399-0804 www.bartlett.us.com CITY OF ROCKY MOUNT DEPT. OF ENGINEERING DETAILS APPROVED STD. NO. 3.7 DATE 01-31-03 REVISION SEE TERMINUS DETAILS A & B CONSTRUCTION NOTES L FINE GRADE, L ME, FERTILIZE, AND SEED PRIOR TO INSTALLING EROSION MATTING, 2. INSTALL MATTING WITH DIRECTION OF FLOW, EXCEPT AT LAP JOINTS AS ILLUSTRATED IN TERMINUS DETAIL C. 3. LAY MATTING FLAT WITHOUT STRETCHING OR WRINKLING AND SECURE W TH STAPLES AS SHOWN ON TYPICAL CONFIGURATION. SEE TERMINUS DETAILS C & D PRESS ENDS 4' INTO SOIL AROUND STRUCTURES AND STAPLE SECURELY, SEE TERMINUS DETAIL A & B CHANNEL STABILIZATION W/EROSION MATTING (SHEET 1 OF 3) REVISIONS Nn DATE OFSCRIPTTnN CITY OF ROCKY MOUNT DEPT. OF ENGINEERING APPROVED STD. NO. 3.12 DATE 10-09-03 REVISION TRIANGULAR SWALE THICKNESS (T) 4 MIN SLOPE 24 OR FLATTER 2 FILTER LAYER (GRAVEL OR FABRIC) DESIGN FLOW DEPTH PLUS 6' FREEBOARD STONE SIZE THICKNESS (T) CLASS A 9" CLASS B 12" CLASS I 18" CLASS II 24" TRAPEZOIDAL CHANNEL 5 IN THICKNESS <T> SLOPE 1MN OR FLATTER SLOPE 211 OR FLATTER 2 FILTER LAYER (GRAVEL OR FABRIC) DESIGN FLOW DEPTH PLUS 6' FREEBOARD GENERAL NOTES] STONE SHALL BE CLASS 'A', 13', 'I', OR Mt STONE AS DESCRIBED IN SECTION 1042 OF THE NCDOT STANDARD SPECIE CATIONS FOR ROADS B. STRUCTURES <SSRS.) FILTER FABRIC FOR UNDERLAYMENT SHALL MEET REQUIREMENTS OF SECTION 1056 OF THE NCDOT SSRS, GRADED GRAVEL FOR UNDERLAYMENT SHALL BE CLEAN STONE MEETING GRADATION REQUIREMENTS FOR N57 OR 067 STONE <41 MIN. THICKNESS.) WIDTH AND SHAPE OF DITCHES SHALL BE AS SHOWN ON THE APPROVED PLAN OR AS DIRECTED BY THE ENGINEER. ALL DIMENSIONS ARE MINIMUM UNLESS OTHERWISE NOTED ON PLANS, STANDARD RIP RAP CHANNEL LINING NO DATE REVISIONS DESCRIPTION CITY OF ROCKY MOUNT DEPT. OF ENGINEERING APPROVED STD. NO. 3.10 DATE 04-10-00 REVISION 6' TYPICAL STAPLE PATTERN "A" TYPICAL STAPLES TYPICAL STAPLE PATTERN "C" TYPICAL STAPLE PATTERN "B" TYPICAL STAPLE PATTERN "D" 20" MTV CHANNEL STABILIZATION W/EROSION MATTING (SHEET 3 OF 3) REVISIONS DFSCRIPTION CITY OF ROCKY MOUNT DEPT OF ENGINEERING APPROVED 3.14 DATE 04-10-00 OLDE MILL STREAM (PHASE 2) CITY OF ROCKY MOUNT, NC REVISION SYMBOL CONSTRUCTION 1, LAY ONE BLOCK ON EACH SIDE OF THE STRUCTURE AND INSERT A 2' X 4' WOOD STUD THREIUGH THE BLOCK VOID AWAY FROM THE INLET OPENING TO ALLOW FOR OVERFLOW. LAY A ROW OF BLOCKS AGAINST THE WOOD STUD ACROSS THE FRONT OF THE BASIN. 2. CAREFULLY FIT HARDWARE CLOTH OR COMPARABLE WIRE MESH WITH 1/2' OPENING OVER ALL BLOCK OPENINGS ALLOWING ENOUGH APRON FOR THE GRAVEL FILTER TO ANCHOR THE MESH AND ENOUGH MESH TO OVERLAP CASTING AND COVER OVERFLOW. 3. USE KOUT 1157 OR EQUAL CLEAN GRAVEL TO TOP OF BLOCKS PLACED AT 24 OR FLATTER SLOPE. SPECIFICATICINS MAINTENANCE 1. INSPECT THE BARRIER AFTER EACH RAIN AND MAKE REPAIRS AS NEEDED. 2. REMOVE SEDIMENT AS NECESSARY TO PREIVIDE ADEQUATE STORAGE VOLUME FOR SUBSEQUENT RAINS. 3, WHEN THE CONTRIBUTING DRAINAGE AREA HAS BEEN ADEQUATELY STABILIZED. REMOVE ALL MATERIALS AND ANY UNSTABLE SOIL. AND EITHER SALVAGE OR DISPOSE OF PROPERLY. BRING THE DISTURBED AREA TO PROPER GRADE. THEN SMOOTH AND COMPACT IT. APPROPRIATELY STABILIZE ALL BARE AREAS AROUND THE INLET. PAVEMENT OR STREET STONE BASE FLO CONCRETE MASONARY BLOCKS .41 PLAN WIRE SCREEN ELEVATION SOIL OR GRAVEL DIKE MAY BE NECESSARY BEHIND CURB IF GROUND IS LOWER THAN TOP OF CONCRETE CURB 11 GUTTER CL1RB INLET TEMPORARY BLOCK AND GRAVEL CURB INLET PROTECTION NO DATE REVISIONS DESCRIPTION OPTIONAL TYPE.,:ig SILT BASIN • CITY OF ROCKY MOUNT DEPT. OF ENGINEERING BASE OF DITCH 12' SEDIMENT TRAP TEMP. STONE DITCH CHECK 12' MIN. STRUCTURAL STONE SEDIMENT CONTROL STONE ELEVATION VIEW alatAkilit • CROSS SECTION VEE DITCH NATURAL GROUND NOTES' APPROVED BACK SLOPE ISOMETRIC VIEW STD. NO. 3.5 REVISION EDGE OF PAVEMEN - NATURAL GROUND CROSS SECTION TRAPEZOIDAL DITCH STRUCTURAL STONE SHALL BE 'CLASS B' STONE FOR EROSMN CONTROL. TEMPORARY ROCK SILT CHECK TYPE-B REVISIONS NO DATE DESCRIPTION CITY OF ROCKY MOUNT DEPT. OF ENGINEERING APPROVED 3.9 DATE 04-10-00 REVISION 1/3 PIPE LDIAMETER 1/3 PIPE LDIAMETER UPSTREAM END OF STORM DRAIN 3/4' EXTERIOR PLYWOOD PLYWOOD INLET PROTECTION UPSTREAM END OF STORM DRAIN HARDWARE CLOTH STONE FILTER INLET PROTECTION BURY BOTTOM OF PLYWOOD STEEL FENCE POST <TYR) WASHED STONE FILTER ACROSS PIPE INLET NOTE' ALL PARTIALLY COMPLETED STORM DRAINS SHALL BE PROTECTED AT THE END OF EACH DAY IN ACCORDANCE WITH THESE REVISIONS PIPE INLET PROTECTION (PLYWOOD & STONE) Nn DATE DFSCRIPTMN DATE: AUGUST 2020 SCALE(HORZ): SCALE(VERT): CITY OF ROCKY MOUNT DEPT. OF ENGINEERING • APPROVED STD. NO. 3.16 DATE REVISION Certification by the Department of Development Services that this construction plat was approved by the city planning board on day of 20 Director of Development Services Certification by the City Engineering Department that this construction plat and required improvement drawings meet the appropriate city standards. Director of Engineering PROJECT: 20-042 CLIENT CODE: RHC FIELD BOOK: DRAWN BY: RF SURVEY BY: JB ROCKY MOUNT TWNSP NASH COUNTY NORTH PIN # SHEET DT1 11:27AM EST 0 al ro 0 cc ra a. DATE I 01-31-03 (SEDIMENT BASIN SCHEDULE'. RISER STRUCTURE SEDIMENT BASIN SB# TOTAL I DISTURBED' Tc Cc I AREA AREA : RUNOFF INTENSITY; Q-10 ACRES ACRES I MN COEFF • N/HR CFS REQ SURFACE SO FT REQ WEIR j VOL ;LENGTH; WIDTH DEPTH LENGTH; BAFFLES CF FT 1 FT 1 FT. E FT I REQ PROP PROP j AREA - PROP BAFFLE PLACEMENT SKIMMER ORIFICE DEWATERING SURFACE:SIDE SLOPE; BOTTOM -VOLUME (MEASURED FROM INFLOW END ). SIZE SIZE TIME SO FT 1 FT/FT SO. FT. ! CF BAFFLE1' BAFFLE BAFFLE3 IN I N. DAYS 1 ; 22.17 I 18.52 5 0.5 7.51 1 69.53 30246 33330 AS SHOWN 2.0 30 1 YES 39600 3:1 33560 54299 AS SHOVMV 4.0 2.75 3.3 MINIMUM WEIR WIDTH = ;WET MINIMUM SURFACE AREA = SKIMMER SEDIMENT BASIN SCHEDULE 435 jSF/CFS Q10 1 MNMUM VOLUME = 1800 CU FT/DISTURBED ACRE SKIMMER TOTAL BASH AREA SK# ACRES DISTURBED AREA ACRES Tc MIN Cc I RUNOFF INTENSITY COEFF H/HR 0-10 CFS REQ REQ SURFACE; VOL L:W LENGTH SQ FT .1 CF RATIO FT WIDTH DEPTH FT FT WEIR LENGTH FT PROP I PROP 1 AREA BA FFLES1 SURFACE SIDE SLOPE BOTTOM REO SQ FT FT/FT 1 SQ.FT. PROP 1 BAFFLE PLACEMENT ISKMMER ORIFICEIDEWATERNG VOLUME(MEASURED FROM INFLOW END) SIZE SIZE j TIME CF i BAFFLE I; BAFFLE 2,BAFFLE 3 IN N.[ DAYS 1 6.76 2 j 952 6.76 9.52 7.51 7.51 25.38 j 8250 12169 j 2.00 35.75 1 11620 17138 ; 2.58 130 66 1 2.0 I 24 ; 3 8450 3:1 ( 6254 186 72 2.0 ; 34 3 13375 i 3:1 1 10426 14649 1 33 23739� 46 65 9 98 139 2.0 1.75 j 4.20 2.5 2.00 4.05 'MINIMUM WEIR WDTH = 4' "REQUIRED VOLUMED IS 1800 CU FT/DISTURBED ACRE DITCH CALCULATIONS 10 YEAR DESIGN STORM LOCATION n= 0.015 DRAINAGE AREA SQ.FT. DRAINAGE] RUNOFF RAINFALL REQUIRED] ---AREA COEFFICIENT] 10-YEARFLOW ACRES 1 IWHR Q DITCH BOIT SLOPE WDT s ! d OM FLLOOH1 SIDE !FLOWWETTED IHYDRAULICMANN.i ACTUAL TOP H SLOPEiA ._-1 REA PERIMETER] RADIUS i VEL. 1CAPACRYIVNDTH y I M( A j P R IV; Q 1 W SHEAR PERiMt STRESS LINER (Ibs/sq.ft,) I REWIRED TEMP. LINER REQUIRED TEMPORARY LINER TYPE SWALE#1 SWALE#2A SWALE#2B SWALE#3A SWALE#3B TEMPORARY TEMPORARY TEMPORARY TEMPORARY TEMPORARY TEMPORARY DIVERSION #1 DIVERSION #2 DIVERSION #3 DIVERSION #4 DIVERSION #5 DIVERSION#6 364291 0.84 25554; 0.59 132941 0.31 50727 1.16 24585 • 0.56 269877; 94834'1 1 2768641 I 2575041 4330551 1268301 0.50 7.51 I 3.14 10.0075 0 0.50 7.51 2.20 10,0030 0 0.50 ! 7.51 1.15 0.0200 0.50 7.51 ,.I. 4.37 �� 0.0145 0.50 1 7.51 2.12 1 0.0033 6.200.50 7.51 ; 23.26 0.0080 2.18 0.50 7.51 8.17 0.0048 6.36 0.50 7.51 23.87 0.0033 5.91 I 0.50 1 7.51 22.20 ; 0.0075 9.94 d 0.35 1 7.51 .0 26.130 0 � 45 2.91 0.35 I 7.51 7.65 ! 0,0045 0.55 0.57 0.31 0.55 0.55 3 ! 0.90 0.97 0.29 0.90 0.91 0.87 j 3 0.85 3 1.08 3 0 1.14 ; 3 2 1.05 3 0 0.84 3 3.46 3.60 1.97 3,46 3.48 0.26 0.27 0.15 0.26 0.26 3.50 ; 3.14 1 3 28 0.26 2.27 1. 2.20-,_I3.41 0,11 3.93 ' 1,15 I 1.87 0.39 487 1 437 I 3.28 0.50 2.33 i 2.12 1 3.30 0.11 3.98 7.48 0.53 5.84 23,26 2.17 5,38 0.40 3.76 8.17 5.64 8.81 0.64 4.24 23,87 3.89 7.20 0.54 15.71 j 22,20 5.37 1 8.61 0.62 ! 4,86 j 26.13 12.12 5 32 1 0.40 1 3.61 ; 7.65 7.20 0.43 5.11 0.25 8.46 0.22 6.83 0.53 8.27 0.29 5.04 0 24 NO NO NO YES NO YES NO YES YES YES NO YES YES YES YES YES YES YES YES YES YES YES STRAW W/ NET STRAW W/ NET STRAW W/ NET STRA W W/ NET STRAW W/ NET STRAW W/ NET STRAW W/ NET STRAW W/ NET STRAW W/NET STRAW W/ NET STRAW W/ NET PLANNING AND DESIGN -_.. 1 HYDRAULIC; MANN I ACTUAL ; ..... MANUAL)! ITOP WIDTH I. SHEAR VR n _. FROM CHART 10 DITCH YEAR .... CALCULATIONS DESIGN LOCATION STORM (n VALUES -FULLY I I OBTAINED PERM VEGETATED ;DRAINAGE: FROM CHART :... _ C CHANNELS 8.05c I REQUIRED OF THE DITCH NC EROSION BOTTOM FLOW AND SEDIMENT SIDE . !__.. ;FLOW CONTROL ,1 I I LINER ' AREA 1COEFFI FLOW SLOPE'1 WIDTH ! ;REQUIRED!...ACRESs . I Q d DEPTH SLOPE] AREA I FERIMETER y I M I A ..1... P RADIUS VEL. 1 CAPACITY 1 _(FLOW) STRESS R i V i Q 1 W ;(Ibs/sq.fi) (RxV) 8.05c p8.05.07 SWALE#3A NO 0.00 1 0.50 4.37 TEMPORARY DIVERSION#1 ! NO 1 6.20 1 0.50 23.26 TEMPORARY DIVERSION#3 I NO 6.36 1 0.50 23.87 1- I 0.0145 0.0080 0.0033 1 0 2 2 0.99 1.41 1.79 1 3 1 2.94 3 I 8.75 3 13,181 6.26 10.89 13.32 0.47 i 1.49 0.80 i 2,66 0.99 1 1.81 0.81 1 2.54 0,94 ( 2.18 i 4.37 1 5.94 0.90 23.26 1 10,44 0.70 23.87 1 12.73 0.37 22.20 1 10.23 0.80 26.13 I 12.15 I 0.48 1 0.70 2.14 1.79 2.06 2.06 0.07 0.04 0.05 0.04 0.04 TEMPORARY DIVERSION#4 NO 1 0.50 22.20 0.0075 0 1.71 3 8.72 ! 10.79 TEMiPORARY DNERSION#5 „591 NO j 9.94 1 0.35 26.13 0.0045 2 1.69 3 1 11.971 12,70 FLOW DEPT (Ya SEE TABLE) TEMPORARY DITCH SECTION NO SCALE FLOW DEPT (Y- SEE TABLE) -- SYMBOL SIDE SLOPES (M =3:1) DITCH SLOPE (5 = SEE TABLE) SIDE SLOPES (M= 3:1) DITCH SLOPES (Si- SEE TABLE) SWALES & TEMPORARY DIVERSIONS TYPICAL SECTION NO SCALE CONSTRUCTION SPECIFICATIONS MAINTENANCE TD 3 TYPE A PIPE OUTLET TO FLAT AREA WITH NO DEFINED CHANNEL A PUN MEW 5EOm0N A -A PROVIDE GEOTEXIILE UNDERUNER OR (MADED GRAVEL FILTER (4' MITI. - /57 WASHED STONE BEDDING MATERIAL) NOTES: A (1) d MI 1.5 TIMES THE MAXIMUM STONE DIAMETER, BUT NOT LESS THAN SIX (6") INCHES. (2) d t " 1' ABOVE MAXIMUM TAILWATER OR TOP OF CHANNEL BANK (WHICHEVER IS LESS.) (3) Lot= LENGTH OF RIPRAP APRON, (TO OBTAIN Lo, USE FIG. 8.06a FOR TYPE A INSTALLATION AND FIG. 8,086 FOR TYPE 8.) REFER TO; NCDENR EROSION AND SEDIMENT CONTROI PI ANNING AND OFSIGN MANUAI TYPE B PIPE OUTLET TO WELL- DEFINED CHANNEL B e • :f•G• - PUN NEW • ,•; t A., 5Ean0N B-0 PROMOS GEOTEXIILE UNDERUNER OR GRADED GRAVEL FILTER (4' MIN. - /57 WASHED STONE BEDDING MATERIAL) NEI. BOTTOM CULVERT OUTLET PROTECTION NTT DATE REVISIONS DFSCRIPTInN CITY OF ROCKY MOUNT DEPT. OF ENGINEERING APPROVED STD. NO. 3.22 DATE 01-31-03 REVISION DISSIPATOR PAD/OUTLET PROTECTION SCHEDULE '(NYDOT METHOD) LOCATION Qmax ( 010 CFS I CFS V10 Vmax FPS FPS PIPE DIA _.. L.__.. 1; INCHES 'ZONE! M NUMBER APRON OF PIPES LENGTH2 (La) FEET APRON VNDTH3 FEET CLASS STONE STONE D50 DEPTH4STONE INCHES SIZE PIPE "LA2' 64.20 26.54 3.03 PIPE "L62' 68.63 - 20.13 195 PIPE "LB21" 27.98 15.57 4.76 PIPES "LC" ' 94.00 67.00 16.51 1. REMOVE AND PROPERLY DISPOSE OF ALL TREES, BRUSH. STUMPS, AND OTHER OBJECTIONABLE MATERIAL. 2. ENSURE THAT THE MINIMUM CONSTRUCTED CROSS SECTION MEETS ALL DESIGN REQUIREMENTS. 3. ENSURE THAT THE TOP OF THE DIKE IS NOT LOWER AT ANY PRINT THAN THE DESIGN ELEVATION PLUS THE SPECIFIED SETTLEMENT. 4. PROVIDE SUFFICIENT ROOM AROUND DIVERSIONS TO PERMIT MACHINE REGRADING AND CLEANOUT. 5. VEGETATE THE RIDGE IMMEDIATELY AFTER CONSTRUCTION, UNLESS IT WILL REMAIN IN PLACE LESS THAN 30 WORKING DAYS. INSPECT TEMPORARY DIVERSIONS ONCE A WEEK AND AFTER EVERY RAINFALL. IMMEDIATELY REMOVE SEDIMENT FROM THE FLOW AREA AND REPAIR THE DIVERSION RIDGE. CAREFULLY CHECK OUTLETS AND MAKE TIMELY REPAIRS AS NEEDED. WHEN THE AREA. PROTECTED IS PERMANENTLY STABILIZED, REMOVE THE RIDGE AND THE CHANNEL TO BLEND WITH THE NATURAL GROUND LEVEL AND APPROPRIATELY STABILIZE IT. COMPACTED SOIL 2' MIN, I1 �1-111 i �11�1IIII�I_I�I 11�11) III 6' TYPICAL 18' MIN. TEMPORARY DIVERSION BERM REVISIONS Nfl BATE PFSCRIPTLN CITY OF ROCKY MOUNT DEPT. OF ENGINEERING APPROVED STD. NO. 3.15 DATE 04-10-00 REVISION BARTLETI" ENGINEERING & SURVEYING, PC 1906 NASH STREET NORTH WILSON, N.C. 27893-1726 License No. C-1551 7.07 7.56 6.04 6.75 ELIBUAUEf1'( OWLET RPRAAP 5• cars; -• NOEL T. DRivE STEEL ENCE POST AT LEAST le INTO SOLID Moulin 2. wOoo POSTS ME NOT ACCEPTABLE 3. USE STAPLES I• APART 10 ATTA[II rARRIC 10 -HOG WIRE' 42 42 30 2 3-30 2 POSOVOePVCCRPROO DUA 6 6 6 PERSPECTIVE VIEW 14 14 10 30 B B B B 22 9 22 9 22 9 22 ,"LET ZONE 35 Or SURFACE AREA St CRUDER 25e Or SURFACE AEA SEC ND CHAMBER suRrACE ARCA OWLET ZONE SUrt RFACE AREA FABRIC FOLDED OVA HORIZONTAL PO HORTZONIAL P05 FENCE N.O EABRI BURIED m TRENCH DACKFILLED •wD COMPACTED F i�- SECTION AT OPENIING BAFFLE PLACEMENT FOR TRAPS BASINS: REVISIONS Nn IATFJ DFSFRIPTITIN TELE: (252) 399-0704 FAX: (252) 399-0804 www.bortlett.us.com CITY OF ROCKY MOUNT DEPT CF ENGINEERING DETAILS APPROVED STD. NO. 3.23 DATE 07-03-07 REVISION PLASTIC SLOPE DRAIN PIPE (PRACTICE STANDARD 6.32) OR GEOTEXTILE LINING TEMPORARY OR PERMANENT DITCH STEEL POSTS (QUANTITYVAR.) COIR FIBER BAFFLES (PRACTICE STANDARD 6.65) RISER STRUCTURE SKIMMER -1' CLASS &STONE PAD (4'X4'X 1' MIN.) 11 PLAN ViEW TRASH RACK :A xf ANTIFL A ION BLOCK %\ cl .l SKIMMER (SIZE VAR.) h STONE PAD--� (below sk mmer TOP OF EMBANKMENT EMBANKMENT i• WOOD -STAKE OR METAL POST 3 P MIN.'�.',(7j:y(, FREEBOARD- 1L I (U �((/s taint i' MIN. �1 III �111 aI Aria Ain :Il iTlliiiul (N )III) eip, l lliil( ` Isla m 111 alidc i AIM tot I l= +; .:..,, SECTIONAL VIEW ti CUT-OFF TRENCH 2' DEEP 1.1 STONE ENERGY DISSIPATOR 014* EMERGENCY SPILLWAY 4- EMERGENCY SPILLWAY k'..c °P �x Iule4 lIII1m1-111 ANTI -SEEP COLLAR 1 NOTES 1. SEED AND PLACE MATTING FOR EROSION CONTROL ON INTERIOR AND EXTERIOR SIDESLOPES. 2. INSTALL A MINIMUM OF 3 COIR FIBER BAFFLES IN ACCORDANCE WITH PRACTICE STANDARD 6.65, 3. INSTALL SKIMMER AND COUPLING TO RISER STRUCTURE OR DIRECTLY INTO EMBANKMENT 1 FT. FROM BOTTOM OF BASIN. 4. THE ARM PIPE SHALL HAVE A MINIMUM LENGTH OF 6 FT. BETWEEN THE SKIMMER AND COUPLING. Figure 6.61d Sediment Basin (milli. Riser Barrel Pipe) CONSTRUCTION SPECIFICATION BARREL [- PIPE STABILIZED OUTLET NOT TO SCALE 1. SITE PREPARATIONS- CLEAR, GRUB, AND STRIP TOPSOIL FROM AREAS UNDER THE EMBANKMENT TO REMOVE TREES, VEGETATION, ROOTS, AND OTHER OBJECTIONABLE MATERIAL. DELAY CLEARING THE POOL AREA UNTIL THE DAM IS COMPLETE AND THEN REMOVE BRUSH, TREES, AND OTHER OBJECTIONABLE MATERIALS TO FACILITATE SEDIMENT CLEANOUT. STOCKPILE ALL TOPSOIL OR SOIL CONTAINING ORGANIC MATTER FOR USE ON THE OUTER SHELL OF THE EMBANKMENT TO FACILITATE VEGETATIVE ESTABLISHMENT. PLACE TEMPORARY SEDIMENT CONTROL MEASURES BELOW THE BASIN AS NEEDED. 2. CUT-OFF TRENCH- EXCAVATE A CUT-OFF TRENCH ALONG THE CENTER LINE OF THE EARTH FILL EMBANKMENT. CUT THE TRENCH TO STABLE SOIL. MATERIAL BUT IN NO CASE MAKE IT LESS THAN 2 FEET DEEP. THE CUT-OFF TRENCH MUST EXTEND INTO BOTH ABUTMENTS TO AT LEAST THE ELEVATION OF THE RISER CREST, MAKE THE MINIMUM BOTTOM WIDTH WIDE ENOUGH TO PERMIT OPERATION OF EXCAVATION AND COMPACTION EQUIPMENT, BUT IN NO CASE LESS THAN 2 FEET. MAKE SIDE SLOPES OF THE TRENCH NO STEEPER THAN 1:1. COMPACTION REQUIREMENTS ARE THE SAME AS THOSE FOR THE EMBANKMENT. KEEP THE TRENCH DRY DURING BACKEILLING AND COMPACTION OPERATIONS. 3. EMBANKMENT- TAKE FILL MATERIAL FROM THE APPROVED AREAS SHOWN ON THE PLANS. IT SHOULD BE CLEAN MINERAL SOIL, FREE OF ROOTS, WOODY VEGETATION, ROCKS, AND OTHER OBJECTIONABLE MATERIAL. SCARIFY AREAS ON WHICH FILL IS TO BE PLACED BEFORE PLACING FILL. THE FILL MATERIAL MUST CONTAIN SUFFICIENT MOISTURE SO IT CAN BE FORMED BY HAND INTO A BALL WITHOUT CRUMBLING. IF WATER CAN BE SQUEEZED OUT OF THE BALL, IT I5 TOO WET FOR PROPER COMPACTION. PLACE FILL MATERIAL IN 6 TO 8 INCH CONTINUOUS LAYERS OVER THE ENTIRE LENGTH OF THE FILL AREA AND COMPACT IT. COMPACTION MAY BE OBTAINED BY ROUTING THE CONSTRUCTION HAULING EQUIPMENT OVER THE FILL SO THAT THE ENTIRE SURFACE OF EACH LAYER IS TRAVERSED BY AT LEAST ONE WHEEL OR TREAD TRACK OF HEAVY EQUIPMENT, OR A COMPACTOR MAY BE USED. CONSTRUCT THE EMBANKMENT TO AN ELEVATION 10 PERCENT HIGHER THAN THE DESIGN HEIGHT TO ALLOW FOR SETTLING. 4. CONDUIT SPILLWAYS- SECURELY ATTACH THE RISER TO THE BARREL OR BARREL STUB TO MAKE A WATERTIGHT STRUCTURAL CONNECTION. SECURE ALL CONNECTIONS BETWEEN BARREL SECTIONS BY APPROVED WATERTIGHT ASSEMBUES. PLACE ME BARREL AND RISER ON A FIRM, SMOOTH FOUNDATION OF IMPERVIOUS SOIL. DO NOT USE PERVIOUS MATERIAL SUCH AS SAND, GRAVEL OR CRUSHED STONE AS BACKFILL AROUND THE PIPE OR ANTI -SEEP COLLARS. PLACE THE FILL MATERIAL AROUND THE PIPE SPILLWAY IN 4-INCH LAYERS, AND COMPACT IT UNDER AND AROUND THE PIPE TO AT LEAST THE SAME DENSITY AS THE ADJACENT EMBANKMENT, CARE MUST BE TAKEN NOT TO RAISE THE PIPE FROM FIRM CONTACT 'MTh ITS FOUNDATION WHEN COMPACTING UNDER THE PIPE HAUNCHES. PLACE A MINIMUM DEPTH OF 2 FEET OF COMPACTED BACKFILL OVER THE PIPE SPILLWAY BEFORE CROSSING IT WITH CONSTRUCTION EQUIPMENT. ANCHOR THE RISER IN PLACE BY CONCRETE OR OTHER SATISFACTORY MEANS TO PREVENT FLOTATION. IN NO CASE SHOULD THE PIPE CONDUIT BE INSTALLED BY CUTTING A TRENCH THROUGH THE DAM AFTER THE EMBANKMENT IS COMPLETE. 5. EMERGENCY SPILLWAY- INSTALL THE EMERGENCY SPILLWAY IN UNDISTURBED SOIL. THE ACHIEVEMENT OF PLANNED ELEVATIONS, GRADE, DESIGN WIDTH, AND ENTRANCE AND EXIT CHANNEL SLOPES ARE CRITICAL TO THE SUCCESSFUL OPERATION OF THE EMERGENCY SPILLWAY. 6. INLETS- DISCHARGE WATER INTO THE BASIN IN A MANNER TO PREVENT EROSION. USE DIVERSIONS WITH OUTLET PROTECTION TO DIVERT SEDIMENT -LADEN WATER TO THE UPPER END OF THE POOL AREA TO IMPROVE BASIN TRAP EFFICIENCY (REFERENCES: RUNOFF CONTROL MEASURES AND OUTLET PROTECTION). 7. EROSION CONTROL- CONSTRUCT THE STRUCTURE SO THAT THE DISTURBED AREA IS MINIMIZED. DIVERT SURFACE WATER AWAY FROM BARE AREAS. COMPLETE THE EMBANKMENT BEFORE THE AREA IS CLEARED. STABIUZE THE EMERGENCY SPILLWAY EMBANKMENT AND ALL OTHER DISTURBED AREAS ABOVE ME CREST OF THE PRINCIPAL SPILLWAY IMMEDIATELY AFTER CONSTRUCTION (REFERENCES: SURFACE STABILIZATION). 8. INSTALL POROUS BAFFLES. 9. SAFETY- SEDIMENT BASINS MAY ATTRACT CHILDREN AND CAN BE DANGEROUS. AVOID STEEP SIDE SLOPES, AND FENCE AND MARK BASINS WITH WARNING SIGNS IF TRESPASSING IS LIKELY. FOLLOW ALL STATE AND LOCAL REQUIREMENTS. MAINTENANCE INSPECT TEMPORARY SEDIMENT BASINS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (1/2 INCH OR GREATER) RAINFALL EVENT AND REPAIR IMMEDIATELY. REMOVE SEDIMENT AND RESTORE THE BASIN TO ITS ORIGINAL DIMENSIONS WHEN IT ACCUMULATES TO ONE-HALF THE DESIGN DEPTH. PLACE REMOVED SEDIMENT IN AN AREA WITH SEDIMENT CONTROLS. CHECK THE EMBANKMENT, SPILLWAYS, AND OUTLET FOR EROSION DAMAGE, AND INSPECT THE EMBANKMENT FOR PIPING AND SETTLEMENT. MAKE ALL NECESSARY REPAIRS IMMEDIATELY. REMOVE ALL TRASH AND OTHER DEBRIS FROM THE RISER AND POOL AREA. PVC End Cap PVC Tee Arm Assembly PERSPECTIVE VIEW END VIEW PVC Elbow Read Cap Flexible Iicm 5chedule40 PVC Pipe SEDIMENT BASIN NO SCALE Water Entry Unit PVC Vent Pipe FRONT VIEW a nomIroNton &hc411e 40 PVCPipc PVC Toe Orifice Note. Bottom Surface Figure 6.64a Schematic of a skimmer,, from Pennsylvania Erosion and Sedln cnt Pailulon Control Manual, March. 2090. SKIMMER DETAIL Certification by the Department of Development Services that this construction plat was approved by the city planning board on _ day of 20_. Director of Development Services Certification by the City Engineering Department that this construction plat and required Improvement drawings meet the appropriate city standards. Director of Engineering Plan View Influx stru:tiir Awvcragcidthw Arve" L Arcot basin water su-(ace of top of pr mirth pilaw elevahe 1 Side elopes Inflow Z•1 or flatter Bernes strutter intent storage zone Wood Stake or Metal Post Dam 8 Stale Pad (41(4'XI' min,) Figure 6.04e Exampleeta sediment basinwith a Dkimmerautet and emelgenoy DpltA•ay, From Pennsylvania Botha and &Himont Pollution Centel Manual, March, 2000. Emergency spfilwcy Embankment (wld(h= 5' min.) CONSTRUCTION SPECIFICATION 1. CLEAR GRUB, AND STRIP THE AREA UNDER THE EMBANKMENT OF ALL VEGETATION AND ROOT MAT. REMOVE ALL SURFACE SOIL CONTAINING HIGH AMOUNTS OF ORGANIC MATTER AND STOCKPILE OR DISPOSE OF IT PROPERLY. HAUL AU. OBJECTIONABLE MATERIAL TO THE DESIGNATED DISPOSAL AREA. PLACE TEMPORARY SEDIMENT CONTROL MEASURES BELOW BASIN AS NEEDED. 2. ENSURE THAT FILL MATERIAL FOR THE EMBANKMENT IS FREE OF ROOTS, WOODY VEGETATION, ORGANIC MATTER, AND OTHER OBJECTIONABLE MATERIAL. PLACE THE FILL IN UFTS NOT TO EXCEED 9 INCHES, AND MACHINE COMPACT IT OVERFILL THE EMBANKMENT 6 INCHES TO ALLOW FOR SETTLEMENT. 3. SHAPE THE BASIN TO THE SPECIFIED DIMENSIONS. PREVENT THE SKIMMING DEVICE FROM SETTUNG INTO THE MUCH BY EXCAVATING A SHALLOW PIT UNDER THE SKIMMER OR PROVIDING A LOW SUPPORT UNDER THE SKIMMER OF STONE OR TIMBER. 4. PLACE THE BARREL (TYPICALLY 4-INCH SCHEDULE 40 PVC PIPE) ON A FIRM, SMOOTH FOUNDATION OF IMPERVIOUS SOIL. DO NOT USE PERVIOUS MATERIAL SUCH AS SAND, GRAVEL OR CRUSHED STONE AS BACKFILL AROUND THE PIPE. PLACE THE FILL MATERIAL AROUND THE PIPE SPILLWAY IN 4-INCH LAYERS AND COMPACT IT UNDER AND AROUND THE PIPE TO AT LEAST ME SAME DENSITY AS ME ADJACENT EMBANKMENT. CARE MUST BE TAKEN NOT TO RAISE THE PIPE FROM THE FIRM CONTACT WITH ITS FOUNDATION WHEN COMPACTING UNDER THE PIPE HAUNCHES. PLACE A MINIMUM DEPTH OF 2 FEET OF COMPACTED BACKFILL OVER THE PIPE SPILLWAY BEFORE CROSSING IT WITH CONSTRUCTION EQUIPMENT. IN NO CASE SHOULD THE PIPE CONDUIT BE INSTALLED BY CUTTING A TRENCH THROUGH THE DAM AFTER THE EMBANKMENT IS COMPLETE. 5. ASSEMBLE THE SKIMMER FOLLOWING THE MANUFACTURERS INSTRUCTIONS, OR AS DESIGNED, 6. LAY THE ASSEMBLED SKIMMER ON THE BOTTOM OF THE BASIN WITH THE FLEXIBLE JOINT AT THE INLET OF THE BARREL PIPE. ATTACH THE FLEXIBLE JOINT TO THE BARREL PIPE AND POSITION THE SKIMMER OVER THE EXCAVATED PIT OR SUPPORT. BE SURE TO ATTACH A ROPE TO THE SKIMMER AND ANCHOR IT TO THE SIDE OF THE BASIN. THIS WILL BE USED TO PULL THE SKIMMER TO THE SIDE FOR MAINTENANCE, 7. EARTHEN SPILLWAYS -INSTALL THE SPILLWAY IN UNDISTURBED SOIL TO THE GREATEST EXTENT POSSIBLE, THE ACHIEVEMENT OF PLANNED ELEVATIONS, GRADE, DESIGN WIDTH, AND ENTRANCE AND EXIT CHANNEL SLOPES ARE CRITICAL TO THE SUCCESSFUL OPERATION OF THE SPILLWAY. THE SPILLWAY SHOULD BE LINED WITH LAMINATED PLASTIC OR IMPERMEABLE GEOTEXIILE FABRIC. THE FABRIC MUST BE WIDE AND LONG ENOUGH TO COVER THE BOTTOM AND SIDES AND EXTEND ONTO THE TOP OF THE DAM FOR ANCHORING IN A TRENCH. THE EDGES MAY BE SECURED WITH 8-INCH STAPLES OR PINS. THE FABRIC MUST BE LONG ENOUGH TO EXTEND DOWN THE SLOPE AND EXIT ONTO STABLE GROUND. THE WIDTH OF THE FABRIC MUST BE ONE PIECE, NOT JOINED OR SPLICED: OTHERWISE WATER CAN GET UNDER THE FABRIC. IF THE LENGTH OF THE FABRIC IS INSUFFICIENT FOR THE ENURE LENGTH OF THE SPILLWAY, MULTIPLE SECTIONS, SPANNING THE COMPLETE WIDTH, MAY BE USED. THE UPPER SECTIONS(S) SHOULD OVERLAP THE LOWER SECTION(S) SO THAT WATER CANNOT FLOW UNDER THE FABRIC, SECURE THE UPPER EDGE AND SIDES OF THE FABRIC IN A TRENCH WITH STAPLES OR PINS. 8. INLETS -DISCHARGE WATER INTO THE BASIN IN A MANNER TO PREVENT EROSION. USE TEMPORARY SLOPE DRAINS OR DIVERSIONS WITH OUTLET PROTECTION TO DIVERT SEDIMENT -LADEN WATER TO THE UPPER ENO OF THE POOL AREA TO IMPROVE BASIN TRAP EFFICIENCY. 9. EROSION CONTROL -CONSTRUCT THE STRUCTURE 50 THAT THE DISTURBED AREA IS MINIMIZED. DIVERT SURFACE WATER AWAY FROM BARE AREAS. COMPLETE THE EMBANKMENT BEFORE THE AREA IS CLEARED. STABILIZE THE EMERGENCY SPILLWAY EMBANKMENT AND ALL OTHER DISTURBED AREAS ABOVE THE CREST OF THE PRINCIPAL SPILLWAY IMMEDIATELY AFTER CONSTRUCTION. 10. INSTALL POROUS BAFFLES AS SPECIFIED IN PRACTICE. 6.65 11. AFTER ALL THE SEDIMENT -PRODUCING AREAS HAVE BEEN PERMANENTLY STABILIZED, REMOVE THE STRUCTURE AND ALL THE UNSTABLE SEDIMENT. SMOOTH THE AREA TO BLEND WITH THE ADJOINING AREAS AND STABIUZE PROPERLY, MAINTENANCE INSPECT SKIMMER SEDIMENT BASINS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (ONE-HALF INCH OR GREATER) RAINFALL EVENT AND REPAIR IMMEDIATELY. REMOVE SEDIMENT AND RESTORE THE BASIN TO ITS ORIGINAL DIMENSIONS WHEN SEDIMENT ACCUMULATES TO ONE-HALF THE HEIGHT OF THE FIRST BAFFLE. PULL THE SKIMMER TO ONE SIDE SO THAT THE SEDIMENT UNDERNEATH IT CAN BE EXCAVATED. EXCAVATE THE SEDIMENT FROM THE ENTIRE BASIN, NOT JUST AROUND THE SKIMMER OR THE FIRST CELL MAKE SURE VEGETATION GROWING IN THE BOTTOM OF THE BASIN DOES NOT HOLD DOWN THE SKIMMER. REPAIR THE BAFFLES IF THEY ARE DAMAGED. RE -ANCHOR THE BAFFLES IF WATER IS FLOWING UNDERNEATH OR AROUND THEM. IF THE SKIMMER IS CLOGGED WITH TRASH AND THERE IS WATER IN THE BASIN, USUALLY JERKING ON THE ROPE WILL MAKE THE SKIMMER BOB UP AND DOWN AND DISLODGE THE DEBRIS AND RESTORE FLOW. IF THESE DOES NOT WORK, PULL THE SKIMMER OVER TO THE SIDE OF THE BASIN AND REMOVE THE DEBRIS. ALSO CHECK THE ORIFICE INSIDE THE SKIMMER TO SEE IF IT IS CLOGGED; IF SO REMOVE THE DEBRIS. IF THE SKIMMER ARM OR BARREL PIPE IS CLOGGED, THE ORIFICE CAN BE REMOVED AND THE OBSTRUCTION CLEARED WITH A PLUMBER'S SNAKE OR BY FLUSHING WITH WATER. BE SURE AND REPLACE THE ORIFICE BEFORE REPOSITIONING THE SKIMMER. CHECK THE FABRIC LINED SPILLWAY FOR DAMAGE AND MAKE ANY REQUIRED REPAIRS WITH FABRIC THAT SPANS ME FULL WIDTH OF THE SPILLWAY. CHECK THE EMBANKMENT, SPILLWAYS, AND OUTLET FOR EROSION DAMAGE, AND INSPECT THE EMBANKMENT FOR PIPING AND SETTLEMENT. MAKE ALL NECESSARY REPAIR IMMEDIATELY. REMOVE ALL TRASH AND OTHER DEBRIS FROM THE SKIMMER AND POOL AREAS. FREEZING WEATHER CAN RESULT IN ICE FORMING IN THE BASIN. SOME SPECIAL PRECAUTIONS SHOULD BE TAKEN IN. THE WINTER TO PREVENT THE SKIMMER FROM PLUGGING WITH ICE. TEMPORARY SKIMMER SEDIMENT BASIN NO SCALE Pipe Flow (outlet control) Full Into Invert a 121,50 Outlet Invert = 121.12 Metaeal RCP Dlamolar (Ina) a 18 Ke • 1.0 0.013 Length (11) =38 24.00 24.101 24.20 4.30 4.40 24.50 24.60 4.70 24.80 4.90 25.00 25.08 25.10 5.20 5.30 5.40 5.50 2.13 2.23 2.33 2.43 2.53 2.63 2.73 2.03 2.93 3.03 3.13 3.10 3.23 3.33 3.53 3.63 CF PIPE FRICTION COEFFICIENTS PIPE 12.60 12.00 13.18 13.46 13.74 14.01 14.27 14.53 14.78 15.03 15.28 16.42 16.52 15.76 1098 16.23 16.45 Outlet 7.1 7.30 7.46 7.62 7.77 703 8.07 0.22 8.37 8.51 0.85 0.72 13.70 8.92 9.18 9.31 COEFFICIENT SMOOTH CEMENT ROUGH CEMENT CORRUGATED METAL SMOOTH STEEL RIVETED STEEL CAST IRON 0.013 0,014 ca Pipe FloW (Inlet Contra') Orifice 1.75 1.05 1.95 2.05 2.15 2.25 2.35 2,45 2.55 2.65 2.75 2.81 2.85 2.95 3.05 3.15 3.25 CFS 12.47 12.76 13.04 13.31 13.84 14.10 14.25 14.35 14.81 1405 15.09 15.33 Welr Flow Riser 0.6 Creel Elev. Pipe Diameter (Ins.) Box Cw 0.00 0.10 0.20 0.30 0.40 0.50 0.80 0.70 0.80 0.00 1.00 1.08 1.10 1.20 1.30 1.40 Spillway Capacity Spreadsheet Chocked: CF 124 3 6.11 13.15 17.29 21.79 28.62 31.78 37.20 40.40 42.92 46.90 55.14 61.62 68.34 By: Orlfic Flow Riser Crest Elev. ▪ 124 Pipe Diameter (Ins.) 0 Bo CO 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 000 1.00 1.06 1.10 1.20 1.30 1.40 1.60 ▪ 0.6 Primary Emergency Spillway Flow Total Spillway Capacity Spillway Flow 9 a MU CFS. 0,00 1.18 3.33 6.11 BAI 12.76 13.04 13.31 13.58 13.84 14.10 14.25 14.36 14.61 14.85 1509 15.33 0.00 13.70 1037 23.72 27.39 30.82 33.55 36.23 38.74 41.09 43.31 44.52 45.42 47.44 49.38 51.24 53.04 Bollom Width 30 Elevation Head 124.00 124.10 124.20 124.30 124.40 124.50 124.60 124.70 124.80 12000 125.06 125.10 125.20 125.30 125.40 125.50 0.00 0.00 000 0.00 0.10 0.20 0.30 0.40 0.50 0.80 0.70 0.76 0.80 0.90 1.00 1.10 1.20 0.00 0,00 0.00 MOO 2.66 7.51 13.80 21.25 29.70 39.04 49.20 55.20 60.11 71.72 84.00 00.91 110.42 alien 0.00 1.16 3.33 6.11 12.07 20.27 26.84 34.58 43.28 52.88 63.30 69.63 74.46 00.33 95.85 112.00 125.75 24.00 24.10 24.20 24,30 24.50 24.60 4.70 4.80 4.90 25.00 25.06 5.10 25.20 25.30 25.40 5.50 Elavallon Notes EMERGENCY SPILLWAY APPROX MAX WATER ELEV OLDE MILL STREAM (PHASE 2) CITY OF ROCKY MOUNT, NC DATE: AUGUST 2020 REVISIONS: PROJECT: 20-042 CLIENT CODE: RHC CADFILE: 20042CP7 FIELD BOOK: DRAWN BY: RF SURVEY BY: KP, JB ROCKY MOUNT TWNSP NASH COUNTY NORTH CAROLINA SHEET DT2 11:29AM EST P: \_CADD\J.ANDPROJECTS\RHO\20042\DWG\20042CP7.dwg, Nov 23, 2020 P NOW .mncNli rin,cnn: Ur.S111vr10N. ADDITIONAL EROSION CONTROL NOTES; 1. APPROVAL OF THIS PLAN PERMITS ONLY THOSE CLEARING AND GRADING ACTIVITIES LISTED WITHIN THIS PLAN. THIS PLAN DOES NOT PERMIT THE CONSTRUCTION OF ANY IMPERVIOUS SURFACE OR STRUCTURE. Certification by the Department of Development Services that this construction plat was approved by the city planning board on day of 20 Director of Development Services Certification by the City Engineering Department that this construction plat and required improvement drawings meet the appropriate city standards. Director of Engineering BARTLETT ENGINEERING & SURVEYING, PC 1906 NASH STREET NORTH WILSON, N.C. 27893-1726 License No. C-1551 TELE: (252) 399-0704 FAX: (252) 399-0804 www.bartiett.us.com 2-311 COARSE AGGREGATE 6' THICK (MIN.) • isisri i:i:i:i:i i:i:rfi:i:i:i:i:i_ •:i i • •i:i:i:i:i:i:•_•.• . 4dP Art Ark Airy- 41,40,401r 10' MIN. FILTER FABRIC TO PUBUC ROAD CLASS B RIPRAP 1/2 DIAMETER OF PIPE OR 12" WHICHEVER IS GREATER CAPACITY OF PIPE = DITCH CAPACITY /I\ TEMPORARY STREAM CROSSING NO SCALE CONSTRUCTION SPECIFICATION: 1. CLEAR THE ENTRANCE AND EXIT AREA OF ALL VEGETATION, ROOTS, AND OTHER OBJECTIONABLE MATERIAL AND PROPERLY GRADE IT. 2. PLACE THE GRAVEL TO THE SPECIFIC GRADE AND DIMENSIONS SHOWN ON THE PLANS, AND SMOOTH IT. 3. PROVIDE DRAINAGE TO CARRY WATER TO A SEDIMENT TRAP OR OTHER SUITABLE OUTLET. 4. USE GEOTEXTILE FABRICS BECAUSE THEY IMPROVE STABILITY OF THE FOUNDATION IN LOCATIONS SUBJECT TO SEEPAGE OR HIGH WATER TABLE MAINTENANCE: MAINTAIN THE GRAVEL PAD IN A CONDITION TO PREVENT MUD OR SEDIMENT FROM LEAVING THE CONSTRUCTION SITE. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH 2-3 INCH STONE. AFTER EACH RAINFALL INSPECT ANY STRUCTURE USED TO TRAP SEDIMENT AND CLEAN IT OUT AS NECESSARY. IMMEDIATELY REMOVE ALL OBJECTIONABLE MATERIALS SPILLED, WASHED, OR TRACKED ONTO PUBLIC ROADWAYS. FOR CROSSINGS OVER CHANNELS/DITCH, INSPECT BLOCKAGE, EROSION OF ABUTMENTS, CHANNEL SCOUR, RIPRAP DISPLACEMENT, OR PIPING. MAKE ALL REPAIRS IMMEDIATELY TO PREVENT FURTHER DAMAGE TO THE INSTALLATION. DETAILS sp: .LVt:I tlNOI I() fatted T^.A7 W-dill CAN aE ..t.\h:I II 1 IN ilia DAY SEC''"ON A -L '1 r,Ih.:tAirfare 01 .r. 'ltpef .itr enema , of installing nlprn ,an a (porting incitation. to irrrl flow mnm,d u lall 1.1: 11:.1'I'A'100N 111:QUI:M'E. i$C1 MI r"t nD1 proullin u,nr1 a llnn should int napin.d 0n the tenanting sa rtnind fin 101 al :(,vchannel nod bunk ,net•ie, la lie. all 2•.1:17 1 (on t %,anon ai nail not hook: W redlines% nod lin Inllr,l and ' ed ,1 Ile' m'pin and the edlin role jumper Tb , , should + �� o 'male of the tialn, redlining control on 1111` pone ono minimize `d.emrbance stay int the Rork noun wlWnm,vrt• p"onalulo. 2 hint Intaallation of all moil merit control Illyti351111.0 11(01 11111111.1Voll by tint aedlnunt co to nrpre anlil beu spot no ha Intl prorated leeiy"nlnk with 1Ito e I,mbinent tin ,"Ill:ull construction rnIrm ore In come nil" r appropriate.. jeTitr aogne e riul ill:. linear U " tui approval for dew fee violators 10 ,1u., 0r e,,nini, tinnily. Work rhoiilil ,ott`i/4: rond,emn,n me enennel dining rid a ore its. 11 etiolating dike odd 1 the rind ends art np inn flow"111 and Ike wit area ,I r the mark „ punrprt',honk dl:el . Giro n ethnic velocity dl.npnI r anode of "Apra v dad top 10 and Huth 0 nhotdd d 1e. mined nn the 1111101111 ddde ill 01 C. enniton, nd replad In tinily r"ddrnl mttm. 5 .11 lr , A ,,idol plm anoint;n k%r flows. The lie , of ,onatrnrldn, 1ln 11101114 bet limited I a n.vhwun or .. for em , ran nth r fount Eh 'took taro I ldl 1m puittpail In it ,,.b %,m' bad111I Wbnnn In thin° 0.20. Th n. aura oh did bu Inc .,1 nil h 11111 Ike Wilier drn.111r b oh Into .be channel billow Ike dnnnrlrcan' anl:alnk slits. rtt twain( 11 I:cl prciLe outequipment W11inn 1OM work a wlitn, wool; la propnerd ottottlt linimentbn. I%nll1e the (Imbue ll'mod t the Letrtlrna n alumni bu rnnnloni, ulndll ntlnri y them 11(31.134 nil Uup,i„i.a 11 II ,Will 'Mould n krnt )led n Indicated rf Wm Vim ' all Imo 'aided t (loath( ors ,,(twain( idiom'tint! ,lel,cnl c v a. All r(railing .rinlnio/ea n he and ofwith duo whit Aed nil ,ulei: nt nideJ �ipul lnrltins n arirn:intni on mil flts. 0 u a• It ,„Il;i,11'ro fro „ h old src11/1.,ont idl a, lb 10 m inical �o W.Itl ,f own Ir1ed end Halt irrd, the elan W MOIL,Lek, idliniky be 111311311 OIL 11ebnn tailori. Anal(' r labil.bed npntt.nn, wawa IlIto Finally. upon,lldh f n net1 or:dimwit tithe amid. old .NV. I,nr.,l dbl.n slto il'I rnrnnted innvune r providing r t In n trot tdl Ict• t. until lie..itnent tomato! 1Iugvitor 11, ,ea Wur u.nunN. PUMP AROUND PRACTICE, N1 f'F\: iStFIVS 1 41'21.I' ' IN . CITY OF ROCKY MOUNT DEPT. OF' ENGINEERING SEEDBED PREPARATION: APPROVED STD. NO. 3.26 DATE 05-20-10 REVISION CHISEL COMPACTED AREAS AND SPREAD TOPSOIL 3" DEEP OVER ADVERSE SOIL CONDITIONS, IF AVAILABLE. RIP ENTIRE AREA 6" DEEP. REMOVE ALL LOOSE ROCK, ROOTS, AND OTHER OBSTRUCTIONS LEAVING SURFACE REASONABLY SMOOTH AND UNIFORM. APPLY AGRICULTURAL UME AND FERTILIZER UNIFORMLY AND MIX WITH SOIL. CONTINUE TILLAGE UNTIL A YELL PULVERIZED, REASONABLY UNIFORM SEEDBED IS PREPARED 4" TO 6" DEEP. SPREAD SEED ON FRESHLY PREPARED SEEDBED AND COVER LIGHTLY WITH SEEDING EQUIPMENT OR CULTIPACKER AFTER SEEDING MULCH IMMEDIATELY AFTER SEEDING AND ANCHOR MULCH. HYDROSEEDING SURFACE ROUGHENING IS PARTICULARLY IMPORTANT WHEN HYDROSEEDING, AS A ROUGHENED SLOPE WILL PROVIDE SOME NATURAL COVERAGE FOR LIME, FERTILIZER, AND SEED. THE SURFACE SHOULD NOT BE COMPACTED OR SMOOTH. FINE SEEDBED PREPARATION IS NOT NECESSARY FOR HYDROSEEDING OPERATIONS: LARGE CLODS, STONES, AND IRREGULARITIES PROVIDE CAVITIES IN WHICH SEEDS CAN LODGE. RATE OF WOOD FIBER (CELLULOSE) APPLICATION SHOULD BE AT LEAST 2,000 LB/ACRE. APPLY LEGUME INOCULANTS AT FOUR TIMES THE RECOMMENDED RATE WHEN ADDING INOCULANT TO A HYDROSEEDER SLURRY. IF A MACHINERY BREAKDOWN OF )4 TO 2 HOURS OCCURS, ADD 50% MORE SEED TO THE TASK, BASED ON THE PROPORTION OF THE SLURRY REMAINING. THIS SHOULD COMPENSATE FOR DAMAGE TO SEED. BEYOND 2 HOURS, FULL RATE OF NEW SEED MAY BE NECESSARY. LIME IS NOT NORMALLY APPLIED WITH A HYDRAULIC SEEDER BECAUSE IT IS ABRASIVE. IT CAN BE BLOWN ONTO STEEP SLOPES IN DRY FORM. CRIMPING STRAW MULCH CRIMPING CAN BE APPLIED TO AREAS ADJACENT TO ANY SECTION OF THE ROADWAY WHERE TRAFFIC IS TO BE MAINTAINED OR ALLOWED DURING CONSTRUCTION IN AREAS WITHIN SIX FEET OF THE EDGE OF PAVEMENT, STRAW IS TO BE APPLIED AND THEN CRIMPED. AFTER THE CRIMPING OPERATION IS COMPLETE, AN ADDITIONAL APPLICATION OF STRAW SHALL BE APPLIED AND IMMEDIATELY TACKED WITH A SUFFICIENT AMOUNT OF UNDILUTED EMULSIFIED ASPHALT. STRAW MULCH SHALL BE OF SUFFICIENT LENGTH AND QUALITY TO WITHSTAND THE CRIMPING OPERATION. CRIMPING EQUIPMENT INCLUDING POWER SOURCE SHALL BE SUBJECT TO THE APPROVAL OF THE ENGINEER PROVIDING THAT MAXIMUM SPACING OF CRIMPER BLADES SHALL NOT EXCEED 8". SEEDING SCHEDULE: TEMPORARY SEEDING SEEDING MIXTURE GERMAN MILLET RYE (GRAIN) PARTRIDGE PEA SEEDING DATES SOIL AMENDMENTS UMESTONE FERTILI ZER(10-10-10) STRAW MULCH EMULSIFIED ASPHALT TACK PERMANENT SEEDING SEEDING MIXTURE PARTRIDGE PEA INDIAN GRASS GERMAN MILLET SEEDING DATES SOIL AMENDMENTS UMESTONE FERTIUZER(10-10-10) STRAW MULCH EMULSIFIED ASPHALT TACK HYDROSFFDINO, MATERIAL SEED FERRUZER STRAW MULCH TACKIFIER MAINTENANCE: WINTER/EARLY SPRING RATE(LB/ACRE) 120 60 12/1-4/15 2000 LB/ACRE 750 LB/ACRE 4000 LB/ACRE 435 GALLON/ACRE WINTER/EARLY SPRING RATE(LB/ACRE') 200. 10 2/1-4/15 3000-5000 LBS/ACRE 1000 LB/ACRE 4000 LB/ACRE 435 GALLON/ACRE QUANTITY 200 LB/ACRE 500 LB/ACRE 2000 LB/ACRE 100 LB/ACRE SUMMER RATE(LE/ACRE). 40 4/15-8/15 2000 LB/ACRE 750 LB/ACRE 4000 LB/ACRE 435 GALLON/ACRE SUMMER RATE(LB /ACRE) 200 10 15 5/1-8/15 3000-5000 LBS/ACRE 1000 LB/ACRE 4000 LB/ACRE 435 GALLON/ACRE FALL RATE() B/ACRE) 120 60 8/15-12/30 2000 LB/ACRE 1000 LB/ACRE 4000 LB/ACRE 435 GALLON/ACRE FALL BATE(LB/ACRE) 200 10 8/25-10/1 3000-5000 LBS/ACRE 1000 LB/ACRE 4000 LB/ACRE 435 GALLON/ACRE SOME RECOMMENDED GRASS SPECIES MAY REQUIRE TWO YEARS FOR ESTABLISHMENT, DEPENDING ON SITE CONDITIONS. INSPECT SEEDED AREA FOR FAILURE AND MAKE NECESSARY REPAIRS, SOIL AMENDMENTS, AND RESEEDINGS. IF WEEDY EXOTIC SPECIES HAVE OVERTAKEN THE AREA AFTER THE FIRST GROWING SEASON, THE INVADING SPECIES MUST BE ERADICATED TO ALLOW NATIVE SPECIES TO GROW. NATIVE VEGETATIONS ARE DIFFICULT TO MANAGE AND TAKE LONGER TO ESTABLISH. MONITOR THE SITE UNTIL LONG TERM STABILITY HAS BEEN ESTABLISHED. OLDE MILL STREAM (PHASE 2) CITY Of ROCKY MOUNT, NC 2. APPROVAL OF THIS PLAN CONSTITUTES APPROVAL FROM THE CITY OF ROCKY MOUNT ONLY. ADDITIONAL APPROVALS (SUCH AS 401/404 WETLANDS, ETC.) MAY BE REQUIRED PRIOR TO AUTHORIZATION TO BEGIN CLEARING AND GRADING. COPIES OF ALL ADDITIONAL APPROVALS MUST BE PROVIDED TO THE DEPARTMENT OF ENGINEERING UPON RECEIPT. 3. A COPY OF THE APPROVED EROSION CONTROL PLAN MUST BE KEPT ON SITE AT ALL TIMES. THE APPROVED SEDIMENTATION & EROSION CONTROL PLAN SHOULD BE REGARDED AS MINIMUM REQUIREMENTS; ADDITIONAL MEASURES SHALL BE PUT IN PLACE AS NEEDED TO INSURE THAT NO SEDIMENT IS RELEASED FROM THE SITE. 4. EROSION CONTROL MEASURES SHALL BE CONSTRUCTED PRIOR TO ANY CLEARING OR GRADING ACTIVITIES BEYOND THAT NECESSARY TO INSTALL SUCH MEASURES. APPROVAL OF CONSTRUCTED EROSION CONTROL MEASURES SHALL BE OBTAINED IN WRITING FROM ENGINEERING DEPARTMENT STAFF PRIOR TO SITE CLEARING AND GRADING. 5. COPIES OF ALL PERMITS AND APPROVED PLANS MUST BE KEPT ON SITE IN A PERMIT BOX THAT IS CONSPICUOUSLY LOCATED AND EASILY ACCESSIBLE DURING CONSTRUCTION. THIS INCLUDES APPROVED CONSTRUCTION PLANS, APPROVED EROSION CONTROL PLANS, ENCROACHMENT AGREEMENTS, DRIVEWAY PERMITS, WATER/SEWER PERMITS, ETC. 6. CITY OF ROCKY MOUNT ENGINEERING DEPARTMENT PERSONNEL MUST BE GRANTED ACCESS UPON REASONABLE REQUEST TO ANY AND ALL AREAS OF THE SUBJECT SITE FOR THE INSPECTION OF SEDIMENTATION AND EROSION CONTROL ADEQUACY. 7. IF ADDITIONAL EROSION AND SEDIMENTATION CONTROLS ARE REQUIRED TO PREVENT OFFSITE SEDIMENTATION, THESE PLANS MUST BE MODIFIED AND SUBMITTED TO THE DEPARTMENT OF ENGINEERING WITHIN FIVE BUSINESS DAYS FOR APPROVAL AND ADDITION TO THEIR RECORDS. 8. SITE LIES IN FLOOD ZONE X, PER FEMA FIRM # 3720383000J DATED NOVEMBER 3, 2004. pi WRING CI FARING/GRADING ACTIVITIES• a. ENSURE THAT EROSION & SEDIMENTATION CONTROL PLAN IS KEPT ON SITE AT ALL TIMES IN AN APPROPRIATE PERMIT BOX. b. PLACE SILT FENCE PRIOR TO CLEARING/GRADING. CLEAR ONLY ENOUGH TO INSTALL ALL EROSION CONTROL MEASURES AFTER SILT FENCE IS INSTALLED. c. AFTER ALL EROSION CONTROL MEASURES ARE IN PLACE, CALL THE ENGINEERING DEPARTMENT FOR INSPECTION OF EROSION CONTROL DEVICES. d. UPON RECEIPT OF WRITTEN APPROVAL OF EROSION CONTROL IMPLEMENTATION, BEGIN CLEARING/GRADING ACTIVITIES, IN ACCORDANCE WITH SECTION 801 OF THE CITY OF ROCKY MOUNT LDC. e. IF OFF SITE SEDIMENTATION IS OCCURRING, IMMEDIATELY INSTALL APPROPRIATE CONTROL MEASURES TO STOP IT AS NECESSARY. A REVISED PLAN MUST BE FILED WITH THE ENGINEERING DEPARTMENT WITHIN 5 BUSINESS DAYS. ANY OFF SITE SEDIMENTATION THAT HAS OCCURRED MUST BE REMOVED IN ACCORDANCE WITH APPLICABLE REGULATIONS. f. AFTER CLEARING AND GRADING ARE COMPLETE, IMMEDIATELY STABILIZE ALL DISTURBED AREAS WITH SEED AND STRAW (AND NETTING, IF REQUIRED). MIRING CONSTRUCTION ACTIVITIES; a. ENSURE THAT ALL PERMITS AND APPROVED PLANS ARE KEPT ON SITE IN AN APPROPRIATE PERMIT BOX. b. ENSURE THAT NO SEDIMENTATION IS OCCURRING OFF SITE, SEE ABOVE. c. ENSURE THAT ALL APPLICABLE ORDINANCES AND PERMIT CONDITIONS ARE FOLLOWED. d. AFTER ROAD BASE IS INSTALLED, THE DEVELOPER IS RESPONSIBLE FOR PROVIDING TEMPORARY STREET NAME SIGNAGE. UPON INSTALLATION OF CURB AND GUTTER, PERMANENT STREET SIGNAGE (STREET NAMES, STOP SIGNS, ETC.) MUST BE ORDERED THROUGH THE CITY OF ROCKY MOUNT ENGINEERING DEPARTMENT. e. FOR PUBLIC ROADS, PERFORM TESTING ON SUBGRADE TO CONFIRM, OR MODIFY, PRELIMINARY PAVEMENT DESIGN. TESTING SHALL BE IN ACCORDANCE WITH CITY STANDARD SPECIFICATION 02225.1.06 AND GEOTECHNICAL REPORT PROVIDED BY A REGISTERED PROFESSIONAL ENGINEER. APPROVAL OF THE REPORT BY THE CITY IS REQUIRED PRIOR TO ACCEPTANCE OF PROOF ROLL. CONSTRUCTION NOTES: ALL IMPROVEMENTS SHALL CONFORM TO THE CITY OF ROCKY MOUNT'S LAND DEVELOPMENT CODE AND THE MANUAL OF SPECIFICATIONS AND DETAILS. PROJECT PLANS AND BENCHMARKS ARE BASED ON NAVD 88 VERTICAL DATUM AT NAD 83 HORIZONTAL DATUM TO THE ACCURACY SPECIFIED IN 21 NCAC 56.1603 (CLASSIFICATION OF BOUNDARY SURVEYS), PARAGRAPH (1) LOCAL CONTROL NETWORK SURVEYS (CLASS AA) AND 21 NCAC 56.1605 CLASSIFICATION OF VERTICAL CONTROL SURVEYS PHARAGRAPH (1) URBAN AND SUBURBAN VERTICAL CONTROL SURVEYS (CLASS A). WHERE THE CORNERS ARE TIED USING GPS SURVEYING METHODS, THE PROCEDURES USED SHALL CONFORM TO 21 NCAC56.1603 GLOBAL POSITIONING SYSTEM SURVEYS. THE POSITION S OF BOTH THE REFERENCED CORNERS AND THE MONUMENTS USED SHALL BE SHOWN IN X (EASTING) AND Y (NORTHING) AND Z (ELEVATION). THE CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING THAT A MINIMUM OF TWO (2) PROJECT CONTROL MONUMENTS AS SPECIFIED HEREINAFTER ARE INSTALLED BY A REGISTERED PROFESSIONAL LAND SURVEYOR AND SHALL BE FIELD LOCATED BY THE ENGINEER. ALL MONUMENTS SHALL BE CONSTRUCTED OF CONCRETE AND BE AT LEAST FOUR (4) INCHES IN DIAMETER OR SQUARE, NOT LESS THAN THREE (3) FEET IN LENGTH AND INSTALLED WITH THE TOP FLUSH WITH THE FINISHED GROUND. EACH MONUMENT SHALL HAVE A STANDARD METAL PLATE IMBEDDED IN ITS TOP OF NON CORRODIBLE MATERIAL MARKED PLAINLY WITH THE BENCH POINT, THE MONUMENT NUMBER AND IDENTIFIED AS A PART OF THE CITY OF ROCKY MOUNT GEODETIC CONTROL SYSTEM. THE PROJECT CONTROL MONUMENTS SHALL BE LOCATED ON THE STREET RIGHT OF WAY TO FACILITATE CONSTRUCTION CONTROL BUT MAY BE INCORPORATED AS A PROPERTY CONTROL CORNER. IN ALL CASES THE CONTRACTOR SHALL PROTECT PROJECT CONTROL MONUMENT(S) FROM DISRUPTION DUE TO CONSTRUCTION OPERATIONS. THE NORTH CAROLINA GEODETIC SURVEY CAN BE REACHED ON THE WEB AT www.ncgs.state.nc.us. DISTURBED AREA IS IN EXCESS OF 1 ACRE AND FORMAL SEDIMENTATION & EROSION CONTROL PLAN APPROVAL WAS REQUIRED AS A CONDITION OF CONSTRUCTION PLAN APPROVAL. A COPY OF THE APPROVED EROSION CONTROL PLAN MUST BE KEPT ON SITE AT ALL TIMES. THE APPROVED SEDIMENTATION & EROSION CONTROL. PLAN SHOULD BE REGARDED AS MINIMUM REQUIREMENTS; ADDITIONAL MEASURES SHALL BE PUT IN PLACE AS NEEDED TO INSURE THAT NO SEDIMENT IS RELEASED FROM THE SITE. OVERALL IMPERVIOUS AREA IS LESS THAN 15% OF THE SITE OR THE INCREASE IN PEAK DISCHARGE FROM THE SITE IS LESS THAN 10% THEREFORE SITE IS EXEMPT FROM DETENTION REQUIREMENTS. DETENTION AND NUTRIENT MANAGEMENT REQUIREMENTS MUST BE MET WITH THE NEXT PHASE DEVELOPMENT, OR AT SUCH TIME AS ANY OF THE THRESHOLDS FOR THOSE REQUIREMENTS ARE REACHED PER THE LAND DEVELOPMENT CODE WATER AND SEWER PERMIT APPLICATIONS HAVE BEEN WATER PERMIT NUMBER: DEH SN: OB-01879 SEWER PERMIT NUMBER: W00033671 PAYMENT OF WATER AND SEWER SERVICES FEES MAY 972-1127 TO DETERMINE APPLICABLE FEE(S). APPROVED BY THE NCDEQ. PERMIT NUMBERS ARE AS FOLLOWS: BE DUE PRIOR SETTING OF TAPS OR METERS, CONTACT NEGRETE SILVER AT NCDOT AND/OR CITY DRIVEWAY PERMIT IS REQUIRED FOLLOWNG CONSTRUCTION PLAN APPROVAL. NCDOT ENCROACHMENT AGREEMENT IS REQUIRED FOLLOWING CONSTRUCTION PLAN APPROVAL. PAVEMENT SECTION IS REPRESENTATIVE OF A ROADWAY GEOMETRY ONLY. A GEOTECHNICAL REPORT AND PAVEMENT DESIGN SEALED BY A REGISTERED PROFESSIONAL ENGINEER MUST BE APPROVED BY THE CITY ENGINEER PRIOR TO THE PLACEMENT OF ANY ROADWAY IMPROVEMENTS. ALL GEOTECHNICAL TESTING PROCEDURES AND REPORTS SHALL BE IN ACCORDANCE WITH CITY STANDARDS. SUB -GRADE SOIL CONDITION MUST BE EVALUATED AND CERTIFIED, INCLUDING IN -PLACE DENSITY, BY A GEOTECHNICAL ENGINEER FOR CONFORMANCE WITH PAVEMENT DESIGN CONDITIONS AND A PROOF -ROLL MUST BE WITHNESSED AND APPROVED BY CITY ENGINEERING DEPARTMENT REPRESENTATIVE PRIOR TO PLACEMENT OF STONE BASE. SITE LIES IN FLOOD ZONE X WITH A PORTION LOCATED IN THE FLOOD HAZZARD AREA, PER FEMA FIRM # 3830 DATED NOVEMBER 3, 2004. BASE FLOOD ELEVATION IS 118 FT. COPIES OF ALL PERMITS AND APPROVED PLANS SHALL BE PREPARED IN ACCORDANCE WITH CITY STANDARDS AND PROVIDED PRIOR TO FINAL PLAT APPROVAL. THE PROJECT ENGINEER IS RESPONSIBLE FOR RESOLVING ANY DESCREPANCY BETWEEN THE FIELD CONDITIONS AND PLAN ELEVATIONS AND IMPROVEMENTS. FOR THE INSTALLATION OF ELECTRICAL SERVICES, LOCATION OF PAD -MOUNTED TRANSFORMER IF NEEDED AND TO COORDINATE ELECTRICAL TEMPORARY SERVICE, CONTACT PUBLIC UTILITIES AT (252) 972-1273. PRIMARY ELECTRIC LINES AND RELATED FACILITIES SHALL BE INSTALLED 10-FT BEHIND THE CURB/EDGE OF PAVEMENT AT A DEPTH OF NO LESS THAN 48 INCHES OF FINISHED GRADE. CONTACT DARRYL STROTHER (252-467-4808) TO COORDINATE THE PROPOSED ELECTRIC INSTALLATION ROUTE FOR THE INSTALLATION OF GAS SERVICES, CONTACT PUBLIC UTILITIES AT (252) 972-1694. ANY RELOCATION OF EXISTING UTILITIES WILL BE AT THE COST OF THE DEVELOPER/OWNER. THE CITY WILL NOT ACCEPT RESPONSIBILITY FOR DAMAGES TO CURB AND GUTTER OR STREET IMPROVEMENTS IF INSTALLED PRIOR TO UNDERGROUND SERVICES, NOR WILL THE CITY ABSORB THE COST FOR BORINGS TO INSTALL UNDERGROUND SERVICES, PAVEMENT PATCHING OR DAMAGES TO LANDSCAPING. THESE WILL BE THE RESPONSIBILITY OF THE DEVELOPER/OWNER. ROW EASEMENT TO BE SIGNED PRIOR TO INSTALLATION OF UTILITIES. WATER METERS SUPPLIED BY CONTRACTORS SHALL CONTAIN ENCODER REGISTER AND I7RON 50W-2 PIT ERT MODULE FOR RADIO TRANSMITTED READING PER CITY OF ROCKY MOUNT STANDARDS. CONTACT CRM WATER AND SEWER SERVICES DIVISION (252-297-1317) FOR ADDITIONAL INFORMATION OR QUESTIONS. PROVIDE FIRE FLOW CALCULATIONS FOR NEW HYDRANTS. FIRE PROTECTION WATER SUPPLY SYSTEM INCLUDING FIRE HYDRANTS, SHALL BE INSTALLED AND IN SERVICE PRIOR TO RECORDING THE SUBDIVISION, OR IF NO SUBDIVISION IS INVOLVED, SHALL BE INSTALLED PRIOR TO PLACING OF COMBUSTIBLE BUILDING MATERIALS FOR STRUCTURES OR COMBUSTIBLE PRE -TESTED FABRICATED BUILDING ASSEMBLIES ON THE PROJECT SITE OR UTILIZING THEM IN CONSTRUCTION OF BUILDING STRUCTURES. IF PHASED COORDINATION IS PLANNED, COORDINATE INSTALLATION OF THE FIRE PROTECTION WATER SYSTEM IS PERMITTED. FIRE DEPARTMENT VEHICULAR ACCESS TO ALL STRUCTURES UNDER CONSTRUCTION SHALL BE PROVIDED AT ALL TIMES. IN AREAS WHERE GROUND SURFACES ARE SOFT OR LIKELY TO BECOME SOFT, HARD ALL WEATHER SURFACE ROADS SHALL BE PROVIDED AND MAINTAINED. ADDRESS NUMBERS, BOTH COMMERCIAL AND RESIDENTIAL, MUST BE POSTED ON THE FRONT OF THE STRUCTURE NEAREST TO THE MAIN ENTRANCE IN A POSITION TO BE PLAINLY LEGIBLE, VISIBLE, AND UNOBSTRUCTED FROM THE STREET OR ROAD FRONTING THE PROPERTY. EVERY STREET WILL UTILIZE A COMPLETE STREET NAME CONSISTING OF A BASE NAME AND TYPE SUFFIX (Main St.) ASSIGNED ADDRESS MUST BE ISSUED VIA CITY OF ROCKY MOUNT ADDRESSING CERTIFICATE COMPLETED BY THE CITY OF ROCKY MOUNT PLANNING DEPARTMENT ADDRESSING AGENT AND WILL BE VERIFIED THROUGH THE CITY OF ROCKY MOUNT 9-1-1 COORDINATORS OFFICE. ANY CHANGE OR DIVIATION FROM THIS PLAT, PRIOR TO OR DURING CONSTRUCTION, WILL CAUSE ADDRESSING AND / OR STREET NAMES TO BE RE-EVALUATED WITH POSSIBLE SUBSEQUENT CHANGE. CROSS CONNECTION POLICY IS AVAILABLE AT http://www.rockymountnc.gov/utilltles/crossconnectlon.html ALL NEW COMMERCIAL WATER SERVICES AND IRRIGATION SERVICES ARE REQUIRED TO HAVE TESTABLE BACKFLOW PREVENTION ASSEMBLIES (BFP). FIRE SERVICES WITH FDC OR BOOSTER PUMPS ARE REQUIRED TO HAVE REDUCED PRESSURE PRINCIPLE DETECTOR ASSEMBLIES (RPDA). REDUCED PRESSURE ASSEMBLIES ARE REQUIRED FOR HEALTH HAZZARD APPLICATIONS. DOUBLE CHECK VALVE ASSEMBLIES MAY BE USED IN NON HEALTH HAZZARD APPLICATIONS SUCH AS SOME OFFICE, RESTAURANT, AND RETAIL APPLICATIONS. DATE. AUGUST 2020 SCALE(HORZ): SCALE(VERT): PROJECT: 20-042 CLIENT CODE: RHC CADFILE: 20042CP7 FIELD BOOK: DRAWN BY: RF SURVEY BY: KP, JB ROCKY MOUNT TWNSP NASH COUNTY NORTH CAROLINA ZONE: R-6 & 0-1 REVISIONS: CRM 1ST REVIEW COMMENTS 10/13/2020 PIN # SHEET DT3 44 n N re za a. 0 0 0. a 3 n: GROUND STABILIZATION AND MATERIALS HANDLING PRACTICES FOR COMPLIANCE WITH THE NCGO1 CONSTRUCTION GENERAL PERMIT Implementing the details and specifications on this plan sheet will result in the construction activity being considered compliant with the Ground Stabilization and Materials Handling sections of the NCGO1 Construction General Permit (Sections E and F respectively). The permittee shall comply with the Erosion and Sediment Control plan approved by the delegated authority having jurisdiction. All details and specifications shown on this sheet may not apply depending on site conditions and the delegated authority having jurisdiction. SECTION E: GROUND STABILIZATION Required Ground Stabilization Timeframes Site Area Description Stabilize calendar after disturbance within ceasing this Timeframe variations many days land (a) Perimeter swales, perimeter ditches, dikes, slopes and 7 None (b) High (HQW) Quality Zones Water 7 None (c) Slopes 3:1 steeper than 7 If not allowed slopes steeper are than 10' or less 2.1, 14 in days length are and are (d) Slopes 3:1 to 4:1 14 -7 length -7 ditches, Zones -10 days days days and for for perimeter for slopes with perimeter slopes Lake greater slopes dikes, steeper Watershed than and swales, HQW 50' than in 4:1 Falls (e) Areas flatter with than slopes 4:1 14 -10 -7 ditches, there days days for is zero perimeter for perimeter Lake slopes dikes, Watershed swales, and HQW Zones unless Falls slope Note: After the permanent cessation of construction activities, any areas with temporary ground stabilization shall be converted to permanent ground stabilization as soon as practicable but in no case longer than 90 calendar days after the last land disturbing activity. Temporary ground stabilization shall be maintained in a manner to render the surface stable against accelerated erosion until permanent ground stabilization is achieved. GROUND STABILIZATION SPECIFICATION Stabilize the ground sufficiently so that rain will not dislodge the soil. Use one of the techniques in the table below: Temporary',Stabi ization • Temporary grass seed covered with straw or other mulches and tackifiers • Hydroseeding • Rolled erosion control products with or without temporary grass seed • Appropriately applied straw or other mulch • Plastic sheeting • �ermanent;stabi tzation Permanent grass seed covered with straw or other mulches and tackifiers Geotextile fabrics such as permanent soil reinforcement matting Hydroseeding Shrubs or other permanent plantings covered with mulch Uniform and evenly distributed ground cover sufficient to restrain erosion Structural methods such as concrete, asphalt or retaining walls Rolled erosion control products with grass seed POLYACRYLAMIDES (PAMS) AND FLOCCULANTS 1. Select flocculants that are appropriate for the soils being exposed during construction, selecting from the NC DWR List of Approved PAMS/Flocculants. 2. Apply flocculants at or before the inlets to Erosion and Sediment Control Measures. 3. Apply flocculants at the concentrations specified in the NC DWR List of Approved PAMS/Flocculants and in accordance with the manufacturer's instructions. 4. Provide ponding area for containment of treated Stormwater before discharging offsite. 5. Store flocculants in leak -proof containers that are kept under storm -resistant cover or surrounded by secondary containment structures. EQUIPMENT AND VEHICLE MAINTENANCE 1. Maintain vehicles and equipment to prevent discharge of fluids. 2. Provide drip pans under any stored equipment. 3. Identify leaks and repair as soon as feasible, or remove leaking equipment from the project. 4. Collect all spent fluids, store in separate containers and properly dispose as hazardous waste (recycle when possible). 5. Remove leaking vehicles and construction equipment from service until the problem has been corrected. 6. Bring used fuels, lubricants, coolants, hydraulic fluids and other petroleum products to a recycling or disposal center that handles these materials. LITTER, BUILDING MATERIAL AND LAND CLEARING WASTE 1. Never bury or burn waste. Place litter and debris in approved waste containers. 2. Provide a sufficient number and size of waste containers (e.g dumpster, trash receptacle) on site to contain construction and domestic wastes. 3. Locate waste containers at least 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available. 4. Locate waste containers on areas that do not receive substantial amounts of runoff from upland areas and does not drain directly to a storm drain, stream or wetland. 5. Cover waste containers at the end of each workday and before storm events or provide secondary containment. Repair or replace damaged waste containers. 6. Anchor all lightweight items in waste containers during times of high winds. 7. Empty waste containers as needed to prevent overflow. Clean up immediately if containers overflow 8. Dispose waste off -site at an approved disposal facility. 9. On business days, clean up and dispose of waste in designated waste containers. PAINT AND OTHER LIQUID WASTE 1. Do not dump paint and other liquid waste into storm drains, streams or wetlands. 2. Locate paint washouts at least 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available. 3. Contain liquid wastes in a controlled area. 4. Containment must be labeled, sized and placed appropriately for the needs of site. 5. Prevent the discharge of soaps, solvents, detergents and other liquid wastes from construction sites. PORTABLE TOILETS 1. Install portable toilets on level ground, at least 50 feet away from storm drains, streams or wetlands unless there is no alternative reasonably available. If 50 foot offset is not attainable, provide relocation of portable toilet behind silt fence or place on a gravel pad and surround with sand bags. 2. Provide staking or anchoring of portable toilets during periods of high winds or in high foot traffic areas. 3. Monitor portable toilets for leaking and properly dispose of any leaked material. Utilize a licensed sanitary waste hauler to remove leaking portable toilets and replace with properly operating unit. EARTHEN STOCKPILE MANAGEMENT 1. Show stockpile locations on plans. Locate earthen -material stockpile areas at least 50 feet away from storm drain inlets, sediment basins perimeter sediment controls and surface waters unless it can be shown no other alternatives are reasonably available. 2. Protect stockpile with silt fence installed along toe of slope with a minimum offset of five feet from the toe of stockpile. 3. Provide stable stone access point when feasible. 4. Stabilize stockpile within the timeframes provided on this sheet and in accordance with the approved plan and any additional requirements. Soil stabilization is defined as vegetative, physical or chemical coverage techniques that will restrain accelerated erosion on disturbed soils for temporary or permanent control needs. A ocifsczylo <0 <d 0 \0 20 rSANDBAGS (TYP.) OR STAPLES SILT FENCE CLEARLY MARKED SIGNAGE CONCRETE +� NOTING DEVICE (1fl24' MIN.) WASHOUT PLAN 11 SIDE (TYP ONSITE CONCRETE WASHOUT STRUCTURE WITH LINER algae OP LINING SANDBAGPLESS (Try.) OR STA LOWSIVE FILTRATION SOIL BERM SFC110N A -A NOTES• 1. ACTUAL LOCATION DETERMINED IN RELD 2. THE CONCRETE WASHDUT STRUCTURES SHALL BE MAINTAINED WHEN THE UQUID AND/OR SCUD REACHES 75% OF THE STRUCTURES CAPACITY. 3.CONCRETE WASHOUT STRUCTURE NEEDS TO BE CIEARY MARKED %W1H SIGNAGE NOTING DEVICE BELOW GRADE T TO SCAWASHOUT STRUCTURE NOLE SANDBAGS (TIP.) OR STAPLES CLEARLY MARKED SIGNAGE AASNWT NOTING DEVICE (18.X24 MIN.) PLAN 10 MIL PLASTIC UNINO 1.1 SIDE SLOPE TYP.) SANDBAGS (rYP.) OR STAPLES OW FlLVEnoN SOIL BERM NOTES: 1. ACTUAL LOCATION DETERMINED IN FIELD 2. THE CONCRETE WASHOUT STRUCTURES SHALL BE MAINTAINED WHEN THE UQUID AND/OR SCUD REACHES 73.i OF THE STRUCTURES CAPACITY TO PROVIDE ADEQUATE HOLDING CAPACITY YAM A MINIMUM 12 INCHES OF FREEBOARD. 3.CDNCRETE WASHOUT STRUCTURE NEEDS TO BE CLEARY MARKED YMH SIGNAGE NOTING DEVICE ABOVE GRADE WASHOUT STRUCTURE NOT TO SCALE CONCRETE WASHOUTS 1. Do not discharge concrete or cement slurry from the site. 2. Dispose of, or recycle settled, hardened concrete residue in accordance with local and state solid waste regulations and at an approved facility. 3. Manage washout from mortar mixers in accordance with the above item and in addition place the mixer and associated materials on impervious barrier and within lot perimeter silt fence. 4. Install temporary concrete washouts per local requirements, where applicable. If an alternate method or product is to be used, contact your approval authority for review and approval. If local standard details are not available, use one of the two types of temporary concrete washouts provided on this detail. 5. Do not use concrete washouts for dewatering or storing defective curb or sidewalk sections. Stormwater accumulated within the washout may not be pumped into or discharged to the storm drain system or receiving surface waters. Liquid waste must be pumped out and removed from project. 6. Locate washouts at least 50 feet from storm drain inlets and surface waters unless it can be shown that no other alternatives are reasonably available. At a minimum, install protection of storm drain inlet(s) closest to the washout which could receive spills or overflow. 7. Locate washouts in an easily accessible area, on level ground and install a stone entrance pad in front of the washout Additional controls may be required by the approving authority. 8. Install at least one sign directing concrete trucks to the washout within the project limits Post signage on the washout itself to identify this location. 9. Remove leavings from the washout when at approximately 75% capacity to limit overflow events. Replace the tarp sand bags or other temporary structural components when no longer functional. When utilizing alternative or proprietary products, follow manufacturer's instructions. 10. At the completion of the concrete work, remove remaining leavings and dispose of in an approved disposal facility. Fill pit if applicable, and stabilize any disturbance caused by removal of washout. HERBICIDES, PESTICIDES AND RODENTICIDES 1. Store and apply herbicides, pesticides and rodenticides in accordance with label restrictions. 2. Store herbicides, pesticides and rodenticides in their original containers with the label, which lists directions for use, ingredients and first aid steps in case of accidental poisoning 3. Do not store herbicides, pesticides and rodenticides in areas where flooding is possible or where they may spill or leak into wells, stormwater drains, ground water or surface water. If a spill occurs, clean area immediately. 4. Do not stockpile these materials onsite. HAZARDOUS AND TOXIC WASTE 1. Create designated hazardous waste collection areas on -site. 2. Place hazardous waste containers under cover or in secondary containment. 3. Do not store hazardous chemicals, drums or bagged materials directly on the ground. NCGO1 GROUND STABILIZATION AND MATERIALS HANDLING BARTLETT ENGINEERING & SURVEYING, PC 1906 NASH STREET NORTH WILSON, N.C. 27893-1726 License No. C-1551 TELE: (252) 399-0704 FAX: (252) 399-0804 www.bartlett.us.com S&E NCGO1 DETAILS (1 OF 2) OLDE MILL STREAM (PHASE 2) CITY OF ROCKY MOUNT, NC - DATE: AUGUST 2020 SCALE(HORZ): SCALE(VERT): • EFFECTIVE: 04/01 / 19 Certification by the Department of Development Services that this construction plat was approved by the city planning board on _ day of 20 Director of Development Services Certification by the City Engineering Department that this construction plat and required improvement drawings meet the appropriate city standards. Director of Engineering PROJECT: 20-042 CLIENT CODE: RHC CADFILE: 20042CP7 FIELD 800K: DRAWN BY: RF SURVEY BY: KP, J8 ROCKY MOUNT TWNSP NASH COUNTY NORTH CAROLINA ZONE: R-6 & 0-1 REVISIONS: PIN # SHEET DT4 0 N 0 Z a U. µVI 0 i gt 0 0 0 U i W it 0 3 4) U 0 SECTION A: SELF -INSPECTION SELF -INSPECTION, during inspection. or inspection site Inspection normal of RECORDKEEPING of conditions normal the PART business addition, Record. III business be would business delayed hours AND when hours, cause day. REPORTING in accordance until a the storm the Any the safety self time next event -inspection of with business when of the equal the inspection inspections shall table day to on or be Self below. personnel which greater performed were -inspections delayed it When is than to safe upon adverse be 1.0 shall to are in inch the jeopardy perform be occurs noted weather the outside in required commencement the may In next the Inspect Frequency (during normal business hours) Inspection records must include: (1) Rain gauge maintained in good working order Daily Daily If holiday available, attended needed). "zero." approved no rainfall daily periods, record days Days The by amounts. rain permittee the gauge the (and on Division. and which cumulative this observations no no may individual will rainfall determine use rain another are -day occurred made rainfall measurement if rain a shall during site -monitoring weekend information for those inspection be recorded or is un- is as device (2) Measures E&SC At least once per 7 calendar days and within 24 hours of a rain event > 1.0 inch in 24 hours 1 Identification 2 Date 3 Name 4 Indication properly, 5. Description 6. Description, and of time of the person of whether of evidence, the of the maintenance measures inspection, performing the and inspected, the inspection, were operating for the measure, of corrective actions taken. measures needs date (3) discharge outfalls Stormwater (SDOs) At 7 calendar and hours event 24 least hours once days within 24 of a rain > 1.0 per inch in 1. Identification 2. Date and 3. Name 4. Evidence sheen, 5. Indication 6. Description, time of the floating of of person of indicators or of visible evidence, the the discharge suspended sediment inspection, performing of and stormwater date outfalls the solids leaving of corrective inspected, inspection, pollution or discoloration, the site, actions such as taken. oil (4) Perimeter of site At 7 calendar and hours event 24 least hours within of > once days 24 a rain 1.0 per inch in If visible of the 1. Actions the 2. Description, 3. An releases. sedimentation following site explanation taken limits, shall evidence, to as clean is be the found made: up or and date actions outside stabilize of taken site the corrective to limits, sediment actions control then that future a taken, record has left and to (5) (where wetlands or accessible) Streams offsite onsite or At least 7 calendar and hours event 24 hours within of > once per days 24 a rain 1.0 inch in If stream activity, 1. 2. the stream has then this permit. or visible a of the Office wetland has increased record of the evidence and required per Part increased turbidity following date of corrective reports to III, Section visible from the shall the appropriate C, Item sedimentation be construction made: (2)(a) actions Division of this taken, or a and permit Description, Records Regional of (6) Ground stabilization measures After each phase of grading 1. The phase measures, drainage activity, ground 2. Documentation measures timeframe soon as of clearing facilities, construction cover). have or possible. grading an that been (installation and completion or the provided assurance grubbing, redevelopment, required that of within they of installation all ground perimeter land the will -disturbing permanent stabilization required be of provided E&SC storm as NOTE: rain inspection resets the required 7 calendar day inspection requirement. The SECTION B: RECORDKEEPING SELF -INSPECTION, well kept to as the any up-to-date RECORDKEEPING E&SC approved PART plan throughout III shall deviation be AND documented the shall REPORTING coverage be kept in under on the the this site. permit. 1. E&SC The approved The described: approved following Plan Documentation E&SC items E&SC plan must pertaining as be plan The manner Item to Document Documentation Requirements locations, (a) and shown Each does on E&SC not dimensions the significantly approved Measure and has E&SC deviate relative been Plan. installed from elevations the Initial of and E&SC Plan. initial the installation. the sign E&SC and approved Measure an date documentation Measures inspection each shown E&SC the are E&SC Plan report on E&SC the Measure is or required that approved complete, Measures lists on upon initial a each copy date E&SC or if the after This installation of modified site (b) A phase of grading has been completed. Initial Plan and or complete, to indicate date phase. a copy date completion of the and sign approved of an the inspection E&SC report construction (c) in Plan. Ground accordance cover with is the located approved and installed E&SC Initial Plan report ground or and complete, to indicate cover date specifications. a copy date compliance of the and sign approved with approved E&SC an inspection (d) maintenance performed. for all E&SC and repair Measures Complete, date and sign an inspection report. The been requirements have (e) to Corrective E&SC actions have been taken Initial Plan report corrective and or complete, to indicate date a copy date the of and completion the sign approved an inspection of the E&SC Measures. action. 2. (a) (b) (c) In and requirement Additional Division addition available This Records the a electronically shown All maintained upon similar provides general required request. Documentation to to not of used the for inspection provide inspections observations site a [40 complete period -specific equal Plan inspectors as form well documents that the exemption on three as 41] all utility above, the previous the during the of required the project on Record required following coverage, unique hard normal 30 older completion days. Form -copy elements paper site items inspection business after The provided shall it permittee and is Use hours, be of kept that the be unless shall allowed available on record the the be this if or for agency practical: permit E&SC a -available to during conditions copies at times of based of after all Intent the the includes Notice in and years certificate Inspection lieu Division make shall the as received. will records by made records access of 122 data records. and CFR made SECTION C: REPORTING SELF deposition -INSPECTION, 100 be the Act or and 25 on the regional or and below Emergency reported following feet substances G surface (Ref: aware of 143-215.85. in 40 office surface of Occurrences a Requirements but waters CFR stream RECORDKEEPING occurrences: an in Response cannot occurrence within PART excess 110.3 of waters (regardless this or bypasses. III and the wetland. be permit outside of personnel (regardless cleaned reportable 40 timeframes that CFR of that AND normal volume), 117.3) up REPORTING within endanger or reported, or in 662-7956, 24 accordance hours, under hours health 102 he (800) Section shall may of or with CERCLA also the contact 311 the be 1. 2. (a) (b) (a) (b) (c) Occurrences Permittees Reporting After the other reported 858-0368 • • • • Visible Oil Releases of (Ref: Anticipated Noncompliance environment. appropriate a requirements They They They They the spills permittee 40 to shall sediment that report Water sheen becomes must gallons 733-3300. than listed with Tess 25 within hazardous 302.4) bypasses Division Division's are are cause are if: CFR of gallons Other more, S. conditions unanticipated of (800) quantities be volume). and business Section Clean Timeframes or at may the (919) must Occurrence Reporting Timeframes (After Discovery) and Other Requirements (a) deposition stream Visible or sediment in wetland a • • • sediment case If related Within Within Division the stream 24 7 -case causes, staff federal calendar and hours, actions may basis. is named the additional or an waive oral days, permittee state taken on a the or impaired or report the requirements apply electronic to requirement NC address that 303(d) notification. contains the list for cause a as needed a description written of perform the report assure deposition. for if sediment additional staff of on the compliance a - -by the that inspections impaired to practices may be required stringent determine monitoring, with more to waters are conditions (b) release hazardous substances 1(b)-(c) Oil spills of above and per Item • shall location Within 24 include of hours, the information spill an oral or release. or about electronic the date, notification. time, nature, notification volume and The (c) bypasses 122.41(m)(3)] Ant cipated [40 • A report report of at the shall least bypass. ten include days an before evaluation the date of the of the anticipated bypass, quality if possible. and CFR The effect (d) bypasses 122.41(m)(3)] Unant [40 cipated CFR • • quality Within Within 24 7 and calendar hours, effect an days, of oral the or a report bypass. electronic that notification. includes an evaluation of the (e) with of this Noncompliance the endanger 122.41(I)(7)] permit or conditions the that • • • Within Within noncompliance, including been continue; prevent Division case -by 24 7 reoccurrence staff hours, calendar exact and steps may basis. dates and the an days, waive oral its anticipated taken and of causes; a the the or report times, or electronic planned noncompliance. requirement the time that and period if notification. contains the noncompliance to reduce, of noncompliance for noncompliance, [40 a a description eliminate, written CFR is 122.41(I)(6). expected report has and of on the not to a corrected, -case may health environment[40 CFR NCGO1 SELF -INSPECTION, RECORDKEEPING AND REPORTING BARTLETT ENGINEERING & SURVEYING, PC 1906 NASH STREET NORTH TELE: (252) 399-0704 WILSON, N.C. 27893-1726 FAX: (252) 399-0804 License No. C-1551 www.bartiett.us.com S&E NCGO1 DETAILS (2 OF 2) OLDE MILL STREAM (PHASE 2) CITY OF ROCKY MOUNT, NC DATE. AUGUST 2020 SCALE(HORZ): SCALE(VERT): REVISIONS: EFFECTIVE: 04/01 / 19 Certification by the Department of Development Services that this construction plat was approved by the city planning board on _ day of 20 Director of Development Services Certification by the City Engineering Department that this construction plat and required Improvement drawings meet the appropriate city standards. Director of Engineering PROJECT: 20-042 CLIENT CODE: RHC CADFILE: 20042CP7 FIELD BOOK: DRAWN BY: RF SURVEY BY: KP, JB ROCKY MOUNT TWNSP NASH COUNTY NORTH CAROLINA PIN # ZONE: R-6 & 0-1 SHEET DT5 W 0 0 N 0 a. N n 0 0 0 0 5. 0 0 0 0 S 5. 0