Loading...
HomeMy WebLinkAbout20120892 Ver 1_401 Application_20120912201 2089 2 Soil & Environmental Consultants, PA 11010 Raven Ridge Road • Raleigh, North Carolina 27614 • Phone: (919) 846 -5900 • Fax: (919) 846 -9467 www.SandEC.com To: NC Division of Water Quality WebSCaPe Unit Attn: Karen Higgins 512 N. Salisbury Street (9th floor) Raleigh, NC 27603 From: Deborah Edwards Soil & Environmental Consultants, P.A. 11010 Raven Ridge Road Raleigh, NC 27614 Re: Forest Ridge Commercial -Lot C5 & Access Road Harnett County, NC September 27, 2012 S &EC Project #11774.P1 On behalf of the applicant, Forest Ridge Subdivision, Inc. (Attn: Kenneth W. Smith), please find attached a complete application and supplemental information requesting written concurrence from the NC Division of Water Quality that the activities proposed below may proceed under the Isolated and other non -404 jurisdictional wetlands and waters Permit ( IWGP 100000). Please contact me at (919) 846 -5900 if you have any questions or require additional information. PROJECT SUMMARY Project Name Forest Ridge Commercial -Lot C5 & Access Road Project Type Commercial Lot Owner / Applicant Forest Ridge Subdivision, Inc County Harnett Nearest Town Spring Lake Waterbody Name Muddy Creek Overhills Lake Basin / Sub -basin Cape Fear/18 -23 -26 Class C IMPACT SUMMARY Stream Impact (acres): 0 Wetland Impact (acres): 0 Isolated Wetland Impact (acres): 0.09 Total Impact to Waters of the U S. (acres) 0 Total Stream Impact (linear feet): 0 Total Riparian Buffer Impact (square feet): 0 Attachments: Pre - construction Notification Application Form Agent Authorization Form USGS Topographic Map NRCS Sod Survey Map Justification Letter Overall Site Plan & Impact Map Stormwater Narrative (2 copies) Stormwater Permit Application I Forest Ridge Access Road Site (2 copies) Data CD DWQ Application Fee ($240) copies) SEP 2 7 2012 \O�0F W ALIZ,? o -c 20120892 Office Use Only: Corps action ID no. DWQ project no. Form Version 1.3 Dec 10 2008 Pre - Construction Notification (PCN) Form A. Applicant Information 1. Processing 1 a. Type(s) of approval sought from the Corps: E] Section 404 Permit El Section 10 Permit 1 b. Specify Nationwide Permit (NWP) number: N/A or General Permit (GP) number: N/A 1c. Has the NWP or GP number been verified by the Corps? ® Yes ❑ No 1d. Type(s) of approval sought from the DWQ (check all that apply): ❑ 401 Water Quality Certification — Regular ® Non -404 Jurisdictional General Permit ❑ 401 Water Quality Certification — Express ❑ Riparian Buffer Authorization 1e. Is this notification solely for the record because written approval is not required? Notirication not required to Corps, isolated wetland impacts only. For the record only for DWQ 401 Certification: El Yes ®No For the record only for Corps Permit: El Yes E] No 1f. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts? If so, attach the acceptance letter from mitigation bank or in -lieu fee program. ❑ Yes ® No 1 g. Is the project located in any of NC's twenty coastal counties. If yes, answer 1 h below. ❑ Yes ® No 1 h. Is the project located within a NC DCM Area of Environmental Concern (AEC)? I ❑ Yes ® No 2. Project Information 2a. Name of project: Forest Ridge Commercial -Lot C5 & Access Road 2b. County: Harnett 2c. Nearest municipality / town: Spring Lake 2d. Subdivision name: Forest Ridge 2e. NCDOT only, T.I.P or state project no: N/A 3. Owner Information 3a. Name(s) on Recorded Deed: Forest Ridge Subdivision, Inc. 3b. Deed Book and Page No. DB: 967, DP: 576 3c. Responsible Party (for LLC if applicable): Kenneth W. Smith, Sr. 3d. Street address: 400 Odell Road 3e. City, state, zip: Spring Lake, NC 28390 3f. Telephone no.: 910- 497 -2020 3g. Fax no.: N/A 3h. Email address: N/A Page 1 of 11 PCN Form — Version 1.3 December 10, 2008 Version 4. Applicant Information (if different from owner) 4a. Applicant is: ❑ Agent ® Other, specify: Applicant is Owner as listed on the Agent Authorization; please copy agent (S &EC) on all correspondence. 4b. Name: Kenneth W. Smith, Sr. 4c. Business name (if applicable): Forest Ridge Subdivision, Inc. 4d. Street address: 400 Odell Road 4e. City, state, zip: Spring Lake, NC 28390 4f. Telephone no.: 910- 497 -2020 4g. Fax no.: N/A 4h. Email address: N/A 5. Agent/Consultant Information (if applicable) 5a. Name: Deborah Edwards 5b. Business name (if applicable): Soil & Environmental Consultants, PA 5c. Street address: 11010 Raven Ridge Road 5d. City, state, zip: Raleigh, NC 27614 5e. Telephone no.: 919 - 846 -5900 5f. Fax no.: 919 - 846 -9467 5g. Email address: DEdwards @SandEC.com Page 2 of 11 B. Project Information and Prior Project History 1. Property Identification 1a. Property identification no. (tax PIN or parcel ID): Portion of 9594 -15 -8719 1 b. Site coordinates (in decimal degrees): Latitude: 35.2509 Longitude: - 79.0282 (DD DDDDDD) (- DD.DDDDDD) 1 c. Property size: <1 acre 2. Surface Waters 2a. Name of nearest body of water (stream, river, etc.) to Muddy Creek (Overhills Lake) proposed project: 2b. Water Quality Classification of nearest receiving water: C, 18 -23 -26 2c. River basin: Cape Fear River Basin 3. Project Description 3a. Describe the existing conditions on the site and the general land use in the vicinity of the project at the time of this application: The subject property is currently wooded with lot C5 graded. The surrounding area is rural with an influx of residential. 3b. List the total estimated acreage of all existing wetlands on the property: 0.09 acres of isolated wetlands. 3c. List the total estimated linear feet of all existing streams (intermittent and perennial) on the property: 0 linear feet of streams 3d. Explain the purpose of the proposed project: The purpose of this project is to construct an access road for lot C5. 3e. Describe the overall project in detail, including the type of equipment to be used: The overall project proposes to impact 0.09 acres of isolated wetlands for the purposes of constructing an access road for commercial lot C5. Heavy equipment associated with commercial development including backhoes, dump trucks, cement mixers and excavators will be utilized. 4. Jurisdictional Determinations 4a. Have jurisdictional wetland or stream determinations by the Corps or State been requested or obtained for this property / ® Yes F1 No El Unknown project (including all prior phases) in the past. Comments: 4b. If the Corps made the jurisdictional determination, what type ®Preliminary El Final of determination was made? 4c. If yes, who delineated the jurisdictional areas? Agency /Consultant Company: Soil & Environmental Consultants, PA Name (if known): Steven Ball Other: 4d. If yes, list the dates of the Corps jurisdictional determinations or State determinations and attach documentation. Crystal Amschler with the USACE verified the wetland to be isolated on July 17, 2012. Please also note that a JD was issued by Brad Shaver for the entire tract on November 7, 2005 (AID 200501133), this JD has since expired. 5. Project History 5a. Have permits or certifications been requested or obtained for ® Yes ❑ No ❑ Unknown this project (including all prior phases) in the past? 5b. If yes, explain in detail according to "help file" instructions. As per the property owner, previous permits were issued for the residential portion of this development. It is my understanding that a Nationwide Permit 12 was authorized and 0.59 acres of temporary impacts (jurisdictional wetlands and waters) were requested. Copies of the final permits /certifications are not available at this time. Page 3 of 11 PCN Form — Version 1.3 December 10, 2008 Version B. Project Information and Prior Project History 6. Future Project Plans 6a. Is this a phased project? ® Yes ❑ No 6b. If yes, explain. There is a plan to develop the remainder of the Forest Ridge Commercial development however detailed plans are not available at this time. Discussions with the USACE have already taken place and these areas will be permitted via an Individual Permit. Page 4 of 11 C. Proposed Impacts Inventory 1. Impacts Summary 1 a. Which sections were completed below for your project (check all that apply): ® Wetlands ❑ Streams - tributaries ❑ Buffers ❑ Open Waters ❑ Pond Construction 2. Wetland Impacts If there are wetland impacts proposed on the site, then complete this question for each wetland area impacted. 2a. 2b. 2c. 2d. 2e. 2f. Wetland impact Type of jurisdiction number — Type of impact Type of wetland Forested (Corps - 404, 10 Area of impact Permanent (P) or (if known) DWQ — non -404, other) (acres) Temporary T W1 ®P ❑ T Fill -Road Isolated ® Yes ❑ No ❑ Corps ® DWQ 0.09 W2 ❑ P ❑ T ❑ Yes ❑ Corps ❑ No ❑ DWQ W3 ❑ P ❑ T ❑ Yes ❑ Corps ❑ No ❑ DWQ W4 ❑ P ❑ T ❑ Yes ❑ Corps ❑ No ❑ DWQ W5 ❑ P ❑ T ❑ Yes ❑ Corps ❑ No ❑ DWQ W6 ❑ P ❑ T ❑ Yes ❑ Corps ❑ No ❑ DWQ 2g. Total wetland impacts 0.09 2h. Comments: 3. Stream Impacts If there are perennial or intermittent stream impacts (including temporary impacts) proposed on the site, then complete this question for all stream sites impacted. 3a. 3b. 3c. 3d. 3e. 3f. 3g. Stream impact Type of impact Stream name Perennial Type of jurisdiction Average Impact number - (PER) or (Corps - 404, 10 stream length Permanent (P) or intermittent DWQ — non -404, width (linear Temporary (T) (INT)? other) (feet) feet) S1 ❑ P ❑ T ❑ PER ❑ Corps ❑ INT ❑ DWQ S2 ❑ P ❑ T ❑ PER ❑ Corps ❑ INT ❑ DWQ S3 ❑ P ❑ T ❑ PER ❑ Corps ❑ INT ❑ DWQ S4 ❑ P ❑ T ❑ PER ❑ Corps ❑ INT ❑ DWQ S5 ❑ P ❑ T ❑ PER ❑ Corps ❑ INT ❑ DWQ S6 ❑ P ❑ T ❑ PER ❑ Corps ❑ INT ❑ DWQ 3h. Total stream and tributary impacts 3i. Comments: Page 5 of 11 PCN Form — Version 1.3 December 10, 2008 Version 4. Open Water Impacts If there are proposed impacts to lakes, ponds, estuaries, tributaries, sounds, the Atlantic Ocean, or any other open water of the U.S. then individually list all open water impacts below. 4a. 4b. 4c. 4d. 4e. Open water Name of waterbody impact number — (if applicable) Type of impact Waterbody type Area of impact (acres) Permanent (P) or Temporary T 01 ❑P ❑T 02 ❑P ❑T 03 ❑P ❑T 04 ❑P ❑T 0. Total open water impacts 4g. Comments: 5. Pond or Lake Construction If pond or lake construction proposed, then complete the chart below. 5a. 5b. 5c. 5d. 5e. Wetland Impacts (acres) Stream Impacts (feet) Upland Pond ID Proposed use or purpose (acres) number of pond Flooded Filled Excavated Flooded Filled Excavated Flooded P1 P2 5f. Total 5g. Comments: 5h. Is a dam high hazard permit required? ❑ Yes ❑ No If yes, permit ID no: 5i. Expected pond surface area (acres): 5j. Size of pond watershed (acres): 5k. Method of construction: 6. Buffer Impacts (for DWQ) If project will impact a protected riparian buffer, then complete the chart below. If yes, then individually list all buffer impacts below. If any impacts require mitigation, then you MUST fill out Section D of this form. 6a. ❑ Neuse ❑ Tar - Pamlico ❑ Other: Project is in which protected basin? ❑ Catawba ❑ Randleman 6b. 6c. 6d. 6e. 6f. 6g. Buffer impact number — Reason Buffer Zone 1 impact Zone 2 impact Permanent (P) or for Stream name mitigation (square feet) (square feet) Temporary T im act required? 61 ❑P ❑T ❑Yes ❑ No B2 ❑P ❑T ❑Yes ❑ No B3 ❑P ❑T El Yes ❑ No 6h. Total buffer impacts 6i. Comments: Page 6 of 11 D. Impact Justification and Mitigation 1. Avoidance and Minimization 1 a. Specifically describe measures taken to avoid or minimize the proposed impacts in designing project. Please see attached "Justification for Near -Term Construction of Partial Access Road at Forest Ridge Development and Associated Impact to Isolated Wetland Parcels ". 1 b. Specifically describe measures taken to avoid or minimize the proposed impacts through construction techniques. Temporary erosion control measures will be installed around project boundaries to avoid and minimize any indirect impacts of remaining jurisdictional wetlands. 2. Compensatory Mitigation for Impacts to Waters of the U.S. or Waters of the State 2a. Does the project require Compensatory Mitigation for impacts to Waters of the U.S. or Waters of the State? ❑ Yes ® No 2b. If yes, mitigation is required by (check all that apply): ❑ DWQ ❑ Corps 2c. If yes, which mitigation option will be used for this project? ❑ Mitigation bank El Payment to in -lieu fee program ❑ Permittee Responsible Mitigation 3. Complete if Using a Mitigation Bank 3a. Name of Mitigation Bank: 3b. Credits Purchased (attach receipt and letter) Type Quantity 3c. Comments: 4. Complete if Making a Payment to In -lieu Fee Program 4a. Approval letter from in -lieu fee program is attached ❑ Yes 4b. Stream mitigation requested: linear feet 4c. If using stream mitigation, stream temperature: ❑ warm ❑ cool ❑cold 4d. Buffer mitigation requested (DWQ only): square feet 4e. Riparian wetland mitigation requested: acres 4f. Non - riparian wetland mitigation requested: acres 4g. Coastal (tidal) wetland mitigation requested: acres 4h. Comments - Complete if Using a Permittee Responsible Mitigation Plan 5a. If using a permittee responsible mitigation plan, provide a description of the proposed mitigation plan. Page 7 of 11 PCN Form — Version 1.3 December 10, 2008 Version 6. Buffer Mitigation (State Regulated Riparian Buffer Rules) — required by DWQ 6a. Will the project result in an impact within a protected riparian buffer that requires buffer mitigation? ❑ Yes ® No 6b. If yes, then identify the square feet of impact to each zone of the riparian buffer that requires mitigation. Calculate the amount of mitigation required. Zone 6c. Reason for impact 6d. Total impact (square feet) Multiplier 6e. Required mitigation (square feet) Zone 1 3 (2 for Catawba) Zone 2 1.5 6f. Total buffer mitigation required: 6g. If buffer mitigation is required, discuss what type of mitigation is proposed (e.g., payment to private mitigation bank, permittee responsible riparian buffer restoration, payment into an approved in -lieu fee fund). 6h. Comments: Page 8 of 11 E. Stormwater Management and Diffuse Flow Plan (required by DWQ) 1. Diffuse Flow Plan 1 a. Does the project include or is it adjacent to protected riparian buffers identified ❑ Yes ® No within one of the NC Riparian Buffer Protection Rules? 1 b. If yes, then is a diffuse flow plan included? If no, explain why. ❑ Yes El No Comments: 2. Stormwater Management Plan 2a. What is the overall percent imperviousness of this project? 36.8% 2b. Does this project require a Stormwater Management Plan? ® Yes ❑ No 2c. If this project DOES NOT require a Stormwater Management Plan, explain why: 2d. If this project DOES require a Stormwater Management Plan, then provide a brief, narrative description of the plan: As per the project engineer. The access road is a new road that will serve commercial development lots along NC Highway 87. Because of the existing grades, the drainage from the access road ties into an existing storm system where it is impractical to treat and there is no room available for treatment. This was discussed over the phone with Annette Lucas on 08- 16 -12. In the next 18 months or so, a regional storm water pond will be sized to treat the commercial lots and the remainder of the future access road. At this time, the storm pond will be designed for 90% TSS removal in lieu of the minimum 85% in order to compensate for the untreated storm water from the access road in this portion of the project. Please note that the DWQ Stormwater Program would be the program reviewing the SMP however this portion of the project is exempt from their review because the disturbance is less than 1 acre. ❑ Certified Local Government 2e. Who will be responsible for the review of the Stormwater Management Plan? ❑ DWQ Stormwater Program ® DWQ 401 Unit 3. Certified Local Government Stormwater Review 3a. In which local government's jurisdiction is this project? ❑ Phase II 3b. Which of the following locally - implemented stormwater management programs ❑ NSW ❑ USMP apply (check all that apply): ❑ Water Supply Watershed ❑ Other: 3c. Has the approved Stormwater Management Plan with proof of approval been ❑ Yes ® No attached? 4. DWQ Stormwater Program Review ❑ Coastal counties ❑ HQW 4a. Which of the following state - implemented stormwater management programs apply ❑ ORW (check all that apply): ❑ Session Law 2006 -246 ❑ Other: 4b. Has the approved Stormwater Management Plan with proof of approval been attached? ❑ Yes ❑ No 5. DWQ 401 Unit Stormwater Review 5a. Does the Stormwater Management Plan meet the appropriate requirements? ❑ Yes ® No *see 2d above 5b. Have all of the 401 Unit submittal requirements been met? ❑ Yes ® No *see 2d above Page 9 of 11 PCN Form — Version 1.3 December 10, 2008 Version F. Supplementary Information 1. Environmental Documentation (DWQ Requirement) 1 a. Does the project involve an expenditure of public (federal /state /local) funds or the ❑ Yes ® No use of public (federal /state) land? 1 b. If you answered "yes" to the above, does the project require preparation of an ❑ Yes ® No environmental document pursuant to the requirements of the National or State (North Carolina) Environmental Policy Act (NEPA/SEPA)? 1c. If you answered "yes" to the above, has the document review been finalized by the ❑ Yes ❑ No State Clearing House? (if so, attach a copy of the NEPA or SEPA final approval letter.) Comments: 2. Violations (DWQ Requirement) 2a. Is the site in violation of DWQ Wetland Rules (15A NCAC 2H .0500), Isolated ❑ Yes ® No Wetland Rules (15A NCAC 2H .1300), DWQ Surface Water or Wetland Standards, or Riparian Buffer Rules (15A NCAC 26.0200)? 2b. Is this an after - the -fact permit application? ❑ Yes ® No 2c. If you answered "yes" to one or both of the above questions, provide an explanation of the violation(s): 3. Cumulative Impacts (DWQ Requirement) 3a. Will this project (based on past and reasonably anticipated future impacts) result in ❑ Yes ® No additional development, which could impact nearby downstream water quality? 3b. If you answered "yes" to the above, submit a qualitative or quantitative cumulative impact analysis in accordance with the most recent DWQ policy If you answered "no," provide a short narrative description. We have reviewed the "DRAFT Intemal Policy, Cumulative impacts and the 401 Water Quality Certification and Isolated Wetland Programs" document prepared by the NC Division of Water Quality on April 10, 2004, version 2 1 The draft states that most small scale commercial projects are unlikely to cause cumulative impacts. This project does not meet any of the three criteria of private projects that can clearly result in cumulative impacts Additionally, the project is located within the Harnett County, therefore the adjacent properties that have potential for development will have the following regulations to protect downstream waters: the Phase 11 NPDES Stormwater Permit Program which includes permitting requirements for Municipal Separate Storm Sewer Systems (MS4s) in addition to post - construction stormwater management requirements. We anticipate that the DWQ will advise us if a qualitative or quantitative impact analysis is required. 4. Sewage Disposal (DWQ Requirement) 4a. Clearly detail the ultimate treatment methods and disposition (non- discharge or discharge) of wastewater generated from the proposed project, or available capacity of the subject facility. This project will connect to a public sewer system. The municipality will ensure capacity is available at the facility prior to plan approval. Page 10 of 11 PCN Form — Version 1.3 December 10, 2008 Version 5. Endangered Species and Designated Critical Habitat (Corps Requirement) 5a. Will this project occur in or near an area with federally protected species or ❑ Yes ® No habitat? 5b. Have you checked with the USFWS concerning Endangered Species Act ❑ Yes ® No impacts? 5c. If yes, indicate the USFWS Field Office you have contacted. ❑ Raleigh ❑ Asheville 5d. What data sources did you use to determine whether your site would impact Endangered Species or Designated Critical Habitat? The NC- Natural Heritage Programs Map Viewer was accessed to search for elemental occurrences of state and federally protected species In the vicinity of the project. It was determined based on the map viewer that there are 6 elemental occurrences within a 2 -mile radius of the project that were listed as either Endangered or Threatened These occurrences are listed below. Federal State Scientific Name Common Name EO Status Protection Protection Status Status Picoides borealis Red - cockaded Woodpecker Historical E E Amorpha georgiana Georgia Indigo -bush Current E FSC Lysimachia asperulifolia Rough -leaf Loosestrife Current E E Parnassia caroliniana Carolina Grass -of- parnassus Current T FSC Parnassia caroliniana Carolina Grass -of- parnassus Historical T FSC Wares cuneifolia Carolina Pineland -cress Historical E References: [NHP] North Carolina Natural Heritage Program Map Viewer [26 September 2012] Department of Environment and Naturual Resources, Office of Conservation, Planning, and Community Affiars, Raleigh, NC Available at http / /www ncnhp orp 6. Essential Fish Habitat (Corps Requirement) 6a. Will this project occur in or near an area designated as essential fish habitat? ❑ Yes ® No 6b. What data sources did you use to determine whether your site would impact Essential Fish Habitat? This project is located in Harnett County, there are no areas designated as essential fish habitat near the proposed project. 7. Historic or Prehistoric Cultural Resources (Corps Requirement) 7a. Will this project occur in or near an area that the state, federal or tribal ❑ Yes ® No governments have designated as having historic or cultural preservation status (e.g., National Historic Trust designation or properties significant in North Carolina history and archaeology)? 7b. What data sources did you use to determine whether your site would impact historic or archeological resources? Records checks at the State Historic Preservation Office or the Office of State Archeology were not performed. However, there were no structures identified within the project area as being >_ 50 yrs old during the wetland delineation 8. Flood Zone Designation (Corps Requirement) 8a. Will this project occur in a FEMA- designated 100 -year floodplain? ❑ Yes ® No 8b. If yes, explain how project meets FEMA requirements: N/A 8c. What source(s) did you use to make the floodplain determination? According to the project engineer, this project is not within a FEMA- designated 100 -yr floodplain. September Applicant/Agent's Signature Deborah Edwards 27, 2012 Applicant/Agent's Printed Name (Agent's signature is valid only if an authorization letter from the applicant Date is provided.) Page 11 of 11 Environmental Consultants, PA Road • Raleigh, North Carolina 27614 • Phone: (919) 846 -5900 • Fax: (919) 846 -9467 www.SandEC.com AGENT AUTHORIZATION FORM All Blanks To Be Filled In By The Current Landowner Name: Forest Ridge Subdivision Inc.-. President Kenneth W. Smith Sr. Address: 400 Odell Road 5Rring Lake NC 28390 Office address Intersection of Highway 24/87 and Melody Lane; Harnett County (Physical address) Phone: 910 -497 -2020 Project Name/ Description: Forest Ridge Commercial S&EC Project # n� I - Date: hgy 9, 2012 The Department of the Army U.S. Army Corps of Engineers, Wilmington District P.O. Box 1890 Wilmington, NC 28402 Attn: L Field Office. Re: Wetlands Related Consulting and Permitting To Whom It May Concern: I, the current proper1y owner, hereby designate and authorize Soil & Environmental Consultants, PA to act in my behalf as my agent in the processing of permit applications, to furnish upon request supplemental information in support of applications, etc. from this day forward. The 9th day of Tuly 2012 This notification supersedes any previous correspondence concerning the agent for this project. NOTICE: This authorization, for liability and professional courtesy reasons, is valid only for government officials to enter the property when accompanied by S &EC staff. You should call S &EC to arrange a site meeting prior to visiting the site. Kenneth W Smith Sr.; President Forest Ridge Corv. Print Property Owner's Name Property Owner's Signature CC. Ms. Karen Higgins cc Mr. Steven Ball NCDENR - DWQ WeSCAPe Soil & Environmental Consultants, PA Archdale Budding 512 N. Salisbury Street, 91" Floor Raleigh, NC 27604 Project Number: 11774YI Project Manager: DE 5cale: I " = 2,000' Date: 0912 G/ 12 Map Title: Figure I - 1:24,000 JSGS Topographic Mar Forest Ridge Access Road Odell A. Smith Properties, LLC Harnett County, NC Source: 1957 Olivia and Overhill5 Quadrangles Soil & Environmental Consultants, PA 11010 Raven Ridge Rd.- Raleigh, NC 27614 (919) 846 -5900 • (919) 846 -9467 Web Page: www.SandEC.com � 1 9 Project Number: I1774YI Project Manager: DE Scale: = 1 ,000' Date: 09/26/ 12 tx Map Title: Figure 2 - NKCS Solt Survey Map Forest Ridge Access Road Odell A. Smith Properties, LLC Harnett County, NC Source: 1994 Harnett Co. Soil Suvey Sheets 9 * 14 CaB -F :5Ite Soil & Environmental Consultants, PA 11010 Raven Ridge Rd.- Raleigh, NC 27614 (919) 846 -5900 •(919)846 -9467 Web Page: www.SandEC.com '4 - _ _ UOI Z K Q Q _ — _ _ _ _ W _ _ — K a 3 aw0 ui e J W p Z g C� a O J x Z N O Q O U m a V O o w a °¢ �'' �`' x o m pm0�0o 0 Q z s u. K O F N to 3 0 W Q w LLJJ 33W WWW>y � J mJ w !- w J Q F N } m Q C� O 0 O T U M d O z w> m� W p p a O 1— O " O z I m z° I 61 U v J y o z w a I N I J} r- / ZzUNN m �� Ra H Z H ZCl) o I w w 2» �p vai 3 3 v U \� Qa�li to 5; Z (� cp w J ❑ O ®o v E ® 63Z Vsa ®� I( I M 3U o Z W W U Y =ea W y Cl) L, o 0� z0 Z U) W .o N O P //�■ cnQ U o Q o ��� W Q W Cl) / LLI ^�^ li /� i� W N O NZ�� 0 0 Q m N Z oC boo ? o> m Z E �.i U a cc - � J° z 0 Q O U > H LLJ O . ,J C C �UjJ 0 W ¢ Z ¢ Y W W O U n W O Cl) U 0 i o a E m it a a o = a / 61 r _ Q , � 6 M V / LL / / Q \ U / / C / p CL Q� Z _O U Qm� L.L h ZCl) Z O U 2 Ir O it J W W Cl) r0 O Z O 0 I z 0� 5; L) m U \ma z U) clrn pm �p H N W Of 0 L, w Li z J Z I 1 l6c' 96Z LLJ U � I p NO Z W O QUUCV ^\I Of Wa U J p Z �– N FAO F- m-#, C% p U w o m 0 Of w J Q N < Z Z o cr cc N O =2 0 N LU W 0 m W in W W a_ J W w Q w Q 0 0 Wl 0 Ln d U FU N N-d p.. d Q+' o V 98 2 w w F- WN Z U I� J V _j m/ >- a 0 1 W W I Z > 1 2 3: ' 1 I .1 1 �1 O N T o W m 7 Z H w LU F � W� GW„ II zC - O CC�NTYpNO a� o� q o� a� i Wd E9�OE�9 ZLOZ 9Z'6 • ZLXI L 311S 11Va3A0 • 6MP dVW lOVdWI 3ARi0 SS30OV-LL9 \S.LOVdWI ONV113M \OM0\QE IIAIO \uoIslAlpgnS s6pla lsa/oj- Zug \suoS pue gl!wS papO \:I - _ _ UOI Z K Q Q _ — _ _ _ _ _ — — _ _ — _ _ — K a 3 aw0 ui e J W p g } a O J x Z N O Q O U m a o Q O o w a °¢ �'' �`' x o m pm0�0o `� Q z s u. K O F N to 3 0 W Q w LLJJ 33W WWW>y � J mJ w !- w J Q F N } m Q C� O 0 O T U M d O z w> m� W p p a O 1— O " O z I m z° I 61 U v J y o z w a I N I J} r- / ZzUNN m �� Ra H Z H o I w w 2» �p vai 3 3 v U \� Qa�li to 5; Z (� cp w J ❑ O ®o v E ® 63Z Vsa ®� I( I M 3U Z W W U Y =ea W y Cl) L, o 0� z0 ° a - O CC�NTYpNO a� o� q o� a� i Wd E9�OE�9 ZLOZ 9Z'6 • ZLXI L 311S 11Va3A0 • 6MP dVW lOVdWI 3ARi0 SS30OV-LL9 \S.LOVdWI ONV113M \OM0\QE IIAIO \uoIslAlpgnS s6pla lsa/oj- Zug \suoS pue gl!wS papO \:I U W U z cu � N �_ � N <zl 7Z W w o 10 cn �/� L o u�'� �2 -i w m U N w V/ Cl) Z N O 2 ¢ J lA W CC LU O Obi zLL wm <..i < �I a � m �q z W J U J W mz�v Z > <n w w J J a ¢ ai _o o_ F mo y m z f.7 z J W cn Z Z U li V W O mom°'° —' yUj i z w w Z OU cc F.. A50\Oz O U P W me .. 0 ¢¢ w O Q O W Q 2 �i Ci � O oc o s¢ x ¢ LU J d t i0 VJ O U a `o n LL Q � � � U � d °ccnau_ a o => o to P, o � -riles -? ? ,� ?MELODY LANE C) + N 0 Wo LL � 0 W J C) ILL Q° C�a c U a 2E 0 0 W in E- C W � �i N CW II � zr a vc Ix o u-) O LC) O un O O rn rn 00 n r7 N N N v I 0 0 Ln O LC) O L() O o rn rn co n n N N N u-) O LC) O un O O rn rn 00 n r7 N N N v I 0 I w z Q Q p�w - co ; in 3 J o a a ia QJ Q M Q LLJ 0O > H F- J (.) V) Z _ ,` 2487 14 GU,oO ENO Z W p O d Y Q o a w a z p r= U 0 W IJ- o m UwaF 0 w 0 3 V d o W 0f J N� (rZ Z Q N O F `` w� c� w a w 05 z a o W 3 �a z0�oz� o � a: ZF- "�3..,,� Q- 0o � emu' O Z6'00� w W i Z w U d w oV) cn / o a� z w 0 I I I I 9L6Z C) LLJ LLJ LLI o z�a� Y Oa J w U �� a pm d 0 L9'66Z d / �P 8 96Z O o; z a Lti'L6Z r :........ O b 6Z a u-) O LC) O un O O rn rn 00 n r7 N N N O O N O O w � 0 w o_ w z Q Q p�w a w Z in 3 J o a a ia QJ Q M Q LLJ 0O > H F- J (.) V) Z _ ,` 2487 14 GU,oO ENO Z W p O d Y Q c� a z p r= U 0 W IJ- o m UwaF 0 w 0 3 V d U W N� (rZ Z J O F `` w� c� w a w o a o W 3 �a z0�oz� H x w ZF- "�3..,,� r- z emu' O x030 _jz Z �a CL W i Z w U d w w z o w F- cn / U O 9z z w 0 I I I I wN LLI o z�a� Y Oa J w U O O N O O w � 0 w z Q Q p�w W W in 3 o a a ia QJ Q M Q LLJ o �ww3 F-m: Ld r- ri p Q o .. LL aQ Z ui Co W a 0<0- CL :2 UwaF 0 N� (rZ Z lL o p p w a w Z a Z oz N Q W 3 w � H x w Z Oo:p�' F � � Wp0 r- z a LU vw W a Q EE ¢ LU pa CL w w w z o w F- 0_ 0 waa O O N O O w � I I I p�w in 3 yI Lf ^< ia QJ Q M Q 11 o I a o .. LL aQ cc N> N >. o v F U- M LLJ c � a w a w U]� �c w ? (n N w IC Q LL z WI J w ~ Nz W iQ I » I IA; INLLPINC LAND ,)UPVEYIN(; CONbTRUCTION LAYOUT C;P5 .SERVICES LAND DEVELOPMLNT 4o9 cdicA(�o DRIVE SUITE 112 FAYETTEVILLE NC 285o6 PRONE j 910 426 -6777 FAX 910 426 -5777 4P 50 51TE LuTioNS. INC. Forest Ridge Access Road Storm Water Narrative The site is currently undeveloped. The site is being developed as an access road for future commercial lots along NC Highway 87. The total disturbed area for the developed is 0.65 acres. The impervious area of the new street and sidewalk is 10,432 sf or 36.8% based on the total disturbed area. Because of the existing grades, the drainage from the access road ties into an existing storm system where it is unpractical to treat, and there is no room available for treatment. This was discussed over the phone with Annette Lucas on August 16, 2012. In the next 18 months or so, a regional storm water pond will be sized to treat the commercial lots and the remainder of the future access road. At this time, the storm pond will be designed for 90% TSS removal in lieu of the minimum 85% in order to compensate for the untreated storm water from the access road in this portion of the project. r4onn uaroima secretary or Mate Fage 1 of t North, C:amlina Efaine F Marsha'it DEPARTMEN 1 VF THE Secretary SEC RETARY oa- STATE PD 130 29622 seleq*t 44C 2762E -0 t9IM7 -2W Date 9/24/2012 Click here to View Document Filings I File an Annual Report I ®A,' Pnnt a Pre - populated Annual Report Fellable PDF Form I Amended A Previous Annual Report I Corporation Names Name Name Type NC ODELL A SMITH PROPERTIES, LLC LEGAL Limited Liability Company Information SOSID: 0714856 Status: Current - Active Effective Date: 3/8/2004 Annual Report Due Date: Citizenship: DOMESTIC State of Inc.: NC Duration: PERPETUAL Annual Report Status: CURRENT Registered Agent Agent Name: SMITH, ODELL ALDEN, JR Office Address: 400 ODELL ROAD SPRING LAKE NC 28390 Mailing Address: 400 ODELL ROAD SPRING LAKE NC 28390 Principal Office Office Address: 400 ODELL ROAD SPRING LAKE NC 28390 Mailing Address: 400 ODELL ROAD SPRING LAKE NC 28390 Officers Title- MANAGER Name: ODELL ALDEN SMITH JR Business Address: 5420 FLINT TAVERN PLACE BURKE VA 22015 Title: MANAGER Name: KENNETH SMITH Business Address: 400 ODELL ROAD SPRING LAKE NC 28390 This website is provided to the public as a part of the Secretary of State Knowledge Base (SOSKB) system Version 3465 http: / /www.secretary.state.nc us/ corporations /Corp.aspx9PitemId= 6202075 9/24/2012 nicheTIMS: Mgdffl r to This mstrunew was pa; Bneftimmphenkrthe • ■ 018142111"N" F" �vICCR 61 OF DEEDS 20 EP 27 @1:8;x.24 PM WIN PG:427 -431 FEE.g3.@e INW # 219f'11 GZNZRAL WARRAMY DEZD on me 20 7 r>t Ile, P A, 150 N McPherson Chufdi Road, Ste B to lie, NC "TI I , FOREST RIDGE G �0.?qo -n& by and betwem GRANTOR FOREST RIDGE SUBDIVISION, INC lhtedea igoatmOrsabrand (heaoteaaeaaedherela a� Smgdar, pland. msoculw^ timnnma or aeater m WnWESWM thattbcGsmm4 Eoravaloablc ooaetdaaf<oa and by Ompresams doeagant. baegam. Sell sod awq a>mo Ile ( intbeCutyof SIrmgL C more potodndy described ae Won. See Attached The properly hmansbove deathbed Was acgwod by arm Amp Showing the above described properly rs rOCer Win NC Bar Ass mum Form No. W ®1974 RnuW 0 19r prhded by Apoemeat wft the NC Bar Au=nt oa -1981 ODELL A SMITH PROPERTIES, LLC 400 Odell Road Spnng Lake, NC 28390 sorxeoms, and and shall include )tofw ucbxbc vbyaclmowledged,has docent mlotarparadoflandarhrmed ett (brmty.NorlhCarobmand HARNETT COUNTY A BY ,.� FOp i I ',1100N WNW OF DEMS ftwR 2W S P 27 11:62"41 PM KIM P6 427 -431 FEE:523.O8 ISM 12 661111 GENERAL WARRANTY DEED Boise Tmtc � + 'r Paoel Mconfier Veld by Comity an the _ day of . ZO By MuVB= to Thom. CWW&Xevil A 150 N McPherm Church Road Ste B FaYetteville. NC 28303 Thu vwmas ly; 1 e. P A, 150 N McPherson Church Road, Ste B Fayetteville, NC Bnefde�anfbrdteludoe T1 1 C FORESTRIDGC .Ga`IO -O(P THIS DEW made thm 30th day by mod batwom GRANTOR GRANTEE FOREST RIDGE SUBDIVISION, INC ODELL A SMITH PROPERTIES, LLC Z11 > / 400 Odell Road Spnng Lake, NC 28390 Thedeargmhaa(inaborend dtmmtaa sa nsedberema�r�m�� pleb macavam. tiunmoe or anber as WIINESSUM fhatthe Granbm form val mble coaetdermhon'taid' and bydtese presents doesgnnt.' s im, mall and oonveyam ilm ( inamestyaf Spnng Lake___, more parbcolarly described as fb0owe. ca. A,m, f-A The property heremabove de=*W was eaganed by Qsantot by A amp showing the above daeatbed property u mcmded is plat NC Bar A=mahoa Farm No. IA ®1976, Revmed ®1977, 20 Prlated by Agreement wrth the NC Bar Auocmdon -1981 S socmwmm, mad ass Wu6 sad shall u cl de alldmtcermmlatarpmrc laflaodmrtmEed amen County, Nc &Qmhmmd HARNETT COUNTY TAX ,.. . BY , madMazeo HIP1111111 Fee xyz oEm 21�:14PM BKM PG:427 -431 FEE423.00 Ism I milli GENERAL WARRANTS DEED The waste by; I�Tio I ca Ile, P A, 150 N Bnefdescnq4teatfortlblodeoC T1 1_ CR ,FOREST RIDGE GRANTOR FOREST RIDGE SUBDIVISION, INC Thedeaign11tlonGniz wand(itanmeaeaandharem se suVtla, pullet, moscubme. femmmo or meta ea Wr NBSSS[H, fleet the Ckwm4 for a val-ble oanmdetstmn mind by 6m prmema does gt11m, bospin, sell end oonvry an0o the m the Cuyaf Spring Lake more pmtzealaly deanbed ad f Mm. See Atimdwd The property hermmebove desm*W was aogvmed by atat - A amp showing the above desatbod property al tacteded in NC Bar Association Fomt No. Ira 01970 Revised A 19Ti MOW by Agreement with the NC Bar Association -1981 mind betwem ODELL A SMITH PROPERTIES, LLC 400 Odell Road Spring lake, NC 28390 20 NC u=mors , andsaeWk and sba11 include 1111 d0coftmurtorpmcelafumdabmoed unea County,Nm>hOmilsoamd Excise Tax: " to Thte was %bby.9 Bnddmrq* at 1br the In TRW DMID node thu 30th day of FOREST RIDGE SUBDIVISION, INC e E8011111111 Foe r�6TTYt��a" "" of OEM 2W EP 27 011-54` Ph 9KIN PG:427 431 MID* INW12WIM cFIWaAZ, WARPUN TY DEED by County an the_ day of PA. 1 SO N McPherson Church ThedowgutonGroutorandGmutwes used ha rem ae amgalsr, phual, etsaBC0lme. te®atae or name, ae WITNE5SB1ii. tbatthe a valuable oometdeeapom sad by these presents doeagrank barge's, eau amd convey msto the c in the city0f Spnng Lake more puncWsdy dowlind ae fol m. See Attached ODELL A SMITH PROPERTIES, LLC 400 Odell Road Spnng Lake, NC 28390 The property haanabove described was ecgmred by Grantor by umtrm A wsp slowing the above descnbod property u r000rded im Plat Boole NC Bar Assocunan Form No W 0 1976, Revoed 0 1977, 2002 Printed by Agreement with the NC Bar Ammmatton -1981 Sufi to saooeasa% and awem4 and shsll mcheda oetptafwha haherebyaeimowledged, hss au thatcestata lutarpatoelofhIDdanuaoed arnett Coamy,NorlhCamhaaand m 90M— page Raleigh, NC 27609 �U HARNETT COUNTY TAX .... BY M! !1111111 ILI ttwwT,r� fact eF cs:eca 2181 :8� :24 PM 8K: P6 42] -431 fEE: ;23.98 (Ili # 118111 GENERAL WARRANTY DEED Excise Tax: " • " Parcel hlcoftmr No Vetted by County m too _ day of .20_ Ile- Mad(Sm to Cl evil A.\150 N McPherson Church Road, Ste 0. Fayetteydic. NC 28303 This sestrumsed was by: 1 Ile, P A. 150 N McPhmon Church Road, Stye B. Fayetteville, NC Bnef desenphon frs the lndar: T l 1 C ,FOREST RIDGE THIS DEED made this 30th day 20 06. by and betwem .,...,.' a. y.� FOREST RIDGE SUBDIVISION, INC r J� The desugastron l3rmatar and (icmtea es used banaa n atngNar, phmd. ma=*q fi mm me our neuter as VinNESSE77 -L dotthe OnmM forevahuable oommdaahm modbydreeapmemodomp md.bargain,Ballandoomq mtodw( in6cCjtyof SMM Lake more parheularly described m fo>iowm. The property henrngbove described was acgomed by (lraoI by A map showing too above descnbod psopmty = recorded is Plat NC Bar Anoc= m Farm No. L3 ®1976, Ravtsed ®1977, 201 Pdmed by Agreemem m* the NC Bar Anoemd m -1981 & ODELL A SMITH PROPERTIES, LLC 400 Odell Road Spnng Lake, NC 28390 and amusm, and aba11 include nVefwlochubembyadmowLAgs4 bas all tlutoat mloterparodoflandshoed mum Grmty,NosthCwob=and Forest Ridge Subdivision, Inc. 400 Odell Road Spring Lake, NC 28390 910 -497 -2020 September 2S, 201 Justification for Near -Term Construction of Partial Access Road at Forest Ridge Development and Associated Impact to Isolated Wetlands Parcel Why the road needs to be constructed separate from other impacts: Permission is requested to impact the isolated wetlands (0.09 acres) shown in the associated diagrams in order to enable the construction of a commercial facility on Lot C -5 at Forest Ridge development Permission for this impact is requested to be considered separately fromthe remaining jurisdictional wetlands existing within the larger approximately 30 acre development Lot C -5 has been acquired by a new owner who is currently prepared to begin construction of a restaurant on the property. The only wetlands associated with proceeding with construction on the 1.0 acre Lot C -5 is the isolated 0.09 acre area that lies within the planned access road. As per guidance from the US Army Corps of Engineers, future wetland impacts for the remaining development will be addressed as an individual permit at a future time. To include the isolated wetland impacts in the application process for the more involved individual permit would significantly delay the construction on Lot C -5 resulting in significant financial hardship for the new owner. The delay would be associated with the time required to develop an overall master plan for the full development and the associated engineering related to determining the additional wetlands impacts and mitigation approaches Why access to Lot C -5 is not feasible to come off of Melody Lane: The design of the access road that is planned to service Lot C -5 is driven by the requirements of the North Carolina Department of Transportation (NC DOT). The Highway 24/87 segment that runs adjacent to the Forest Ridge development has been designated as a "strategic highway corridor" and the associated design requirements are governed by the "superstreet" concept. The commercial lots that lie adjacent to Highway 24/87 (Lots C -1 through C -5 and C -6 through C -8) are required by NCDOT to be accessed from the rear via an access road. The traffic that transitions from Highway 24/87 onto Melody Lane must not be obstructed by traffic that would traverse a driveway directly into Lot C -5 from Melody Lane The planned access road will be the only means of access to Lot C -5 as well as Lots C -2 through C- 4 until an additional right -in /right -out driveway can be designed and receive approval for installation at the north end of the development (adjacent to Lot C -1); and there could be years before this occurs Alden Smith Vice - President Forest Ridge Subdivision, Inc. /v \tft� - r;-a 3�' �~"� �>'. � °�-,�� mot(, �� �� �O� r Y � .,1 _ a� ✓' �.y { {.__�� _n pion 4 y G YO 1 ✓ � f!r 1, ( � ry - f i%7! 't ��� = _ d , /r �. r 7 - �,.-�J rd I ".. •� - fA -� is ry ->7 a r -'-- "� .35o v � l .. ' "�'�.. -� r �, n ,' a "r x. *•ate@ r . •t. . �• 'ri OYr Jp � ` °// 7 � v 4 •• tl.i. _- -"' -- 4 I/ r '- .� rya' / G / V U 1 /� -�-�� • �. 350 Z no 69 J t ��•�.a.� .� 7-. ! ice: ' jti ' /{rte , _ - i, / t / U� 0 U i n� �✓ rf ! �� • �, Pat � Park p 1r+ — 1300 ; ® � 1 ._. ✓ __``�� � • Aso �. \ � t -=:; - �� r" `4� � t .� 6 3- 3_ f t .,.y� � 1 r�• �' � k�� � �i� �' t ti � e t � � \ � � _�+' 3 '"� 1 4 ! DWQ USE ONLY Date Received Fee Paid Permit Number Applicable Rules: ❑ Coastal SW -1995 ❑ Coastal SW - 2008 ❑ Ph II - Post Construction (select all that apply) ❑ Non - Coastal SW- HQW /ORW Waters ❑ Universal Stormwater Management Plan ❑ Other WQ Mgmt Plan: State of North Carolina Department of Environment and Natural Resources Division of Water Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM This form may be photocopied for use as an original I. GENERAL INFORMATION 1. Project Name (subdivision, facility, or establishment name - should be consistent with project name on plans, specifications, letters, operation and maintenance agreements, etc.): Forest Ridge Access Road 2. Location of Project (street address): Off Melodv Lane City:Cameron County:Harnett Zip:28326 3. Directions to project (from nearest major intersection): Turn left onto Melody Lane at the intersection of Melody Lane and NC24 -87 and go approximately 325 feet south on Melody Lane. The project is located on the right. 4. Latitude:350 15' 02.71" N Longitude:790 01'40.91" W of the main entrance to the project. II. PERMIT INFORMATION: 1. a. Specify whether project is (check one): ®New ❑Modification ❑ Renewal w/ Modificationt tRenewals with modifications also requires SWU -102 - Renewal Application Form b. If this application is being submitted as the result of a modification to an existing permit, list the existing permit number , its issue date (if known) , and the status of construction: ❑Not Started ❑Partially Completed* ❑ Completed* *provide a designer's certification 2. Specify the type of project (check one): ❑Low Density ®High Density ❑Drains to an Offsite Stormwater System ❑Other 3. If this application is being submitted as the result of a previously returned application or a letter from DWQ requesting a state stormwater management permit application, list the stormwater project number, if assigned, and the previous name of the project, if different than currently proposed, 4. a. Additional Project Requirements (check applicable blanks; information on required state permits can be obtained by contacting the Customer Service Center at 1- 877 - 623 - 6748): ❑CAMA Major ❑Sedimentation /Erosion Control: ac of Disturbed Area ❑NPDES Industrial Stormwater ®404/401 Permit: Proposed Impacts Wetlands b. If any of these permits have already been acquired please provide the Project Name, Project/ Permit Number, issue date and the type of each permit: 5. Is the project located within 5 miles of a public airport? ®No ❑Yes If yes, see S. L. 2012 -200, Part VI: http:J /portaLncdenr.orgJwel2 vvc lwslsulstateswJrules laws Form SWU -101 Version 06Aug2012 Page 1 of 6 III. CONTACT INFORMATION 1. a. Print Applicant / Signing Official's name and title (specifically the developer, property owner, lessee, designated government official, individual, etc. who owns the project): Applicant/ Organization: Odell A. Smith Properties, LLC Signing Official & Title:Ken Smith /Manager b. Contact information for person listed in item 1a above: Street Address:400 Odell Road City:Spring Lake State:North Carolina Zip:28390 Mailing Address (if applicable): City: State: Zip: Phone: (910 ) 497 -2020 Fax: (910 ) 497 -0569 Email :odellsmithco @embargmail.com c. Please check the appropriate box. The applicant listed above is: ® The property owner (Skip to Contact Information, item 3a) ❑ Lessee* (Attach a copy of the lease agreement and complete Contact Information, item 2a and 2b below) ❑ Purchaser* (Attach a copy of the pending sales agreement and complete Contact Information, item 2a and 2b below) ❑ Developer* (Complete Contact Information, item 2a and 2b below.) 2. a. Print Property Owner's name and title below, if you are the lessee, purchaser or developer. (This is the person who owns the property that the project is located on): Property Owner/ Organization: Signing Official & Title: b. Contact information for person listed in item 2a above: Street Address: City: State: Zip: Mailing Address (if applicable): City:_ Phone: Email: State: Zip: Fax: ( ) a. (Optional) Print the name and title of another contact such as the project's construction supervisor or other person who can answer questions about the project: Other Contact Person/ Organization: Signing Official & Title: b. Contact information for person listed in item 3a above: Mailing Address: City: State: Zip: Form SWU -101 Version 06Aug2012 Page 2 of 7 Phone: Email: 4. Local jurisdiction for building permits: Harnett Cour Point of Contact:Ken Slattum IV. PROJECT INFORMATION Fax: Phone #: (910 ) 893 -7525 1. In the space provided below, briefly summarize how the stormwater runoff will be treated. The access road is a new road that will serve commercial development lots along NC Highway 87. Because of the existing grades, the drainage from the access road ties into an existing storm system where it is impractical to treat and there is no room available for treatment. This was discussed over the phone with Annette Lucas on 08- 16 -12. In the next 18 months or so, a regional storm water pond will be sized to treat the commercial lots and the remainder of the future access road. At this time, the storm pond will be designed for 90% TSS removal in lieu of the minimum 85% in order to compensate for the untreated storm water from the access road in this portion of the project. 2. a. If claiming vested rights, identify the supporting documents provided and the date they were approved: ❑ Approval of a Site Specific Development Plan or PUD Approval Date: ❑ Valid Building Permit Issued Date: ❑ Other: Date: b. If claiming vested rights, identify the regulation(s) the project has been designed in accordance with: ❑ Coastal SW -1995 ❑ Ph 11- Post Construction 3. Stormwater runoff from this project drains to the Cape Fear River basin. 4. Total Property Area: 0.65 acres 5. Total Coastal Wetlands Area: acres 6. Total Surface Water Area: acres 7. Total Property Area (4) - Total Coastal Wetlands Area (5) - Total Surface Water Area (6) = Total Project Area +:0.65 acres + Total project area shall be calculated to exclude the following: the normal pool of impounded structures, the area between the banks of streams and rivers, the area below the Normal High Water (NHW) line or Mean High Water (MHVO line, and coastal wetlands landward from the NHW (or MHW) line. The resultant project area is used to calculate overall percent built upon area (B UA). Non - coastal wetlands landward of the NHW (or MHV0 line may be included in the total project area. 8. Project percent of impervious area: (Total Impervious Area / Total Project Area) X 100 = 36.8 9. How many drainage areas does the project have ?1 (For high density, count 1 for each proposed engineered stormwater BMP. For low density and other projects, use 1 for the whole property area) 10. Complete the following information for each drainage area identified in Project Information item 9. If there are more than four drainage areas in the project, attach an additional sheet with the information for each area provided in the same format as below. Form SWU -101 Version 06Aug2012 Page 3 of 7 Basin Information Drainage Area 1 Drainage Area _ Drainage Area _ Drainage Area Receiving Stream Name Muddy Creek Stream Class * C Stream Index Number * 18 -23 -26 Total Drainage Area (sf) 28,369 On -site Drainage Area (sf) 28,369 Off -site Drainage Area (sf) Proposed Impervious Area ** (sf) 10,432 Impervious Area ** (total) 36.8 Impervious— Surface Area Drainage Area 1 Drainage Area _ Drainage Area _ Drainage Area On -site Buildings /Lots (sf) On -site Streets (sf) 8,676 On -site Parking (sf) On -site Sidewalks (sf) 1,756 Other on -site (sf) Future (sf) Off -site (sf) Existing BUA * ** (sf) Total (sf): 10,432 * Stream Class and Index Number can be determined at: http /Jportal.ncdearr.or web /wq[ps /csu /classi cations Impervious area is defined as the built upon area including, but not limited to, buildings, roads, parking areas, sidewalks, gravel areas, etc. ** *Report only that amount of existing BUA that will remain after development. Do not report any existing BUA that is to be removed and which will be replaced by new B UA. 11. How was the off -site impervious area listed above determined? Provide documentation. n/a Projects in Union County: Contact DWQ Central Office staff to check if the project is located within a Threatened & Endangered Species watershed that maybe subject to more stringent stormwater requirements as per I5A NCAC 02B.0600. V. SUPPLEMENT AND O &M FORMS The applicable state stormwater management permit supplement and operation and maintenance (O &M) forms must be submitted for each BMP specified for this project. The latest versions of the forms can be downloaded from bttp : / /portal.ticd(�nr.orgZw('b/ q/ s /su /b p- manual. VI. SUBMITTAL REQUIREMENTS Only complete application packages will be accepted and reviewed by the Division of Water Quality (DWQ). A complete package includes all of the items listed below. A detailed application instruction sheet and BMP checklists are available frombttp: / /portal.ncdetir. org / web /wq /ws /su /statesw /fornisdocs. The complete application package should be submitted to the appropriate DWQ Office. (The appropriate office may be found by locating project on the interactive online map at http: / /portal.n( denr.org /web /wq /ws /su/ ate.) Please indicate that the following required information have been provided by initialing in the space provided for each item. All original documents MUST be signed and initialed in blue ink. Download the latest versions for each submitted application package from littp://portal.ncdenr.org/web/wq/ws/su/statesw/fon-ns docs. Initials 1. Original and one copy of the Stormwater Management Permit Application Form. 2. Original and one copy of the signed and notarized Deed Restrictions & Protective Covenants Form. (if required as per Part VII below) 3. Original of the applicable Supplement Form(s) (sealed, signed and dated) and O &M agreement(s) for each BMP. 4. Permit application processing fee of $505 payable to NCDENR. (For an Express review, refer to http: / /www.envhelp .org /pages /onestopeVress.hLml for information on the Express program and the associated fees. Contact the appropriate regional office Express Permit Coordinator for additional information and to schedule the required application meeting.) Form SWU -101 Version 06Aug2012 Page 4 of 7 5. A detailed narrative (one to two pages) describing the stormwater treatment /management for 6. A USGS map identifying the site location. If the receiving stream is reported as class SA or the receiving stream drains to class SA waters within 1/2 mile of the site boundary, include the 1/2 mile radius on the map. 7. Sealed, signed and dated calculations (one copy). 8. Two sets of plans folded to 8.5" x 14" (sealed, signed, & dated), including: a. Development/ Project name. b. Engineer and firm. c. Location map with named streets and NCSR numbers. d. Legend. e. North arrow. f. Scale. g. Revision number and dates. h. Identify all surface waters on the plans by delineating the normal pool elevation of impounded structures, the banks of streams and rivers, the MHW or NHW line of tidal waters, and any coastal wetlands landward of the MHW or NHW lines. • Delineate the vegetated buffer landward from the normal pool elevation of impounded structures, the banks of streams or rivers, and the MHW (or NHW) of tidal waters. i. Dimensioned property /project boundary with bearings & distances. j. Site Layout with all BUA identified and dimensioned. k. Existing contours, proposed contours, spot elevations, finished floor elevations. 1. Details of roads, drainage features, collection systems, and stormwater control measures. m. Wetlands delineated, or a note on the plans that none exist. (Must be delineated by a qualified person. Provide documentation of qualifications and identify the person who made the determination on the plans. n. Existing drainage (including off - site), drainage easements, pipe sizes, runoff calculations. o. Drainage areas delineated (included in the main set of plans, not as a separate document). p. Vegetated buffers (where required). 9. Copy of any applicable soils report with the associated SHWT elevations (Please identify elevations in addition to depths) as well as a map of the boring locations with the existing elevations and boring logs. Include an 8.5 "x11" copy of the NRCS County Soils map with the project area clearly delineated. For projects with infiltration BMPs, the report should also include the soil type, expected infiltration rate, and the method of determining the infiltration rate. (Infiltration Devices submitted to WiRO: Schedule a site visit for DWQ to verify the SHWT prior to submittal, (910) 796- 7378.) 10. A copy of the most current property deed. Deed book: 2285 Page No: 427 11. For corporations and limited liability corporations (LLC): Provide documentation from the NC Secretary of State or other official documentation, which supports the titles and positions held by the persons listed in Contact Information, item 1a, 2a, and /or 3a per 15A NCAC 2H.1003(e). The corporation or LLC must be listed as an active corporation in good standing with the NC Secretary of State, otherwise the application will be returned. ht!p://www.secretary.state.nc.us/Corporations/CSearch.asj2x VII. DEED RESTRICTIONS AND PROTECTIVE COVENANTS For all subdivisions, outparcels, and future development, the appropriate property restrictions and protective covenants are required to be recorded prior to the sale of any lot. If lot sizes vary significantly or the proposed BUA allocations vary, a table listing each lot number, lot size, and the allowable built -upon area must be provided as an attachment to the completed and notarized deed restriction form. The appropriate deed restrictions and protective covenants forms can be downloaded from littp://portal.ncde.nr.org/web/wq/ws/su/statesw/fon-ns docs. Download the latest versions for each submittal. In the instances where the applicant is different than the property owner, it is the responsibility of the property owner to sign the deed restrictions and protective covenants form while the applicant is responsible for ensuring that the deed restrictions are recorded. By the notarized signature(s) below, the permit holder(s) certify that the recorded property restrictions and protective covenants for this project, if required, shall include all the items required in the permit and listed on the forms available on the website, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the required covenants cannot be changed or deleted without concurrence from the NC DWQ, and that they will be recorded prior to the sale of any lot. Form SWU -101 Version 06Aug2012 Page 5 of 7 VIII. CONSULTANT INFORMATION AND AUTHORIZATION Applicant: Complete this section if you wish to designate authority to another individual and /or firm (such as a consulting engineer and/or firm) so that they may provide information on your behalf for this project (such as addressing requests for additional information). Consulting Engineer:Scott Brown Consulting Firm: 4D Mailing Address:409 Chicago Drive, Suite 112 City:Fayetteville Phone: (910 ) 426 -6777 ext.102 Email :sbrown @4dsitesolutions.com State:North Carolina Zip:28306 Fax: (910 ) 426 -5777 IX. PROPERTY OWNER AUTHORIZATION (if Contact Information, item 2 has been filled out, complete this section) I, (print or type name of person listed in Contact Information, item 2a) , certify that I own the property identified in this permit application, and thus give permission to (print or type name of person listed in Contact Information, item 1a) with (print or type name of organization listed in Contact Information, item 1a) to develop the project as currently proposed. A copy of the lease agreement or pending property sales contract has been provided with the submittal, which indicates the party responsible for the operation and maintenance of the stormwater system. As the legal property owner I acknowledge, understand, and agree by my signature below, that if my designated agent (entity listed in Contact Information, item 1) dissolves their company and /or cancels or defaults on their lease agreement, or pending sale, responsibility for compliance with the DWQ Stormwater permit reverts back to me, the property owner. As the property owner, it is my responsibility to notify DWQ immediately and submit a completed Name/ Ownership Change Form within 30 days; otherwise I will be operating a stormwater treatment facility without a valid permit. I understand that the operation of a stormwater treatment facility without a valid permit is a violation of NC General Statue 143 -215.1 and may result in appropriate enforcement action including the assessment of civil penalties of up to $25,000 per day, pursuant to NCGS 143 - 215.6. Signature: I, a Notary Public for the State of do hereby certify that Date: County of personally appeared before me this _ day of , and acknowledge the due execution of the application for a stormwater permit. Witness my hand and official seal, SEAL My commission expires Form SWU -101 Version 06Aug2012 Page 6 of 7 X. APPLICANT'S CERTIFICATION I, (print or type name of person listed in Contact Information, item 1a) Ken Smith certify that the information included on this permit application form is, to the best of my knowledge, correct and that the project will be constructed in conformance with the approved plans, that the required deed restrictions and protective covenants will be recorded, and that the proposed project complies with the requirements of the applicable stormwater rules under 15A NCAC 21-1.1000 and any other applicable state stormwater requirements. Signature: I, a Notary Public for the State of , do hereby certify that before me this _ day of Date: County of personally appeared , and acknowledge the due execution of the application for a stormwater permit. Witness my hand and official seal, SEAL My commission Form SWU -101 Version 06Aug2012 Page 7 of 7 O W U) W a: Ir W 0 HAwKSWOaTH PL. X%- 9 D o�'ry OVERLOOK RD. LINDEN y� OAKS a 4r 'F 0 e) Vf --A � 0 F F, IT E S CO 0 cl), --A Aw co w w ry a� F www wvvww f NORTH w w w "'1141 V RAAD M CCESS 1 11 `IF\ :VtzLUI-'MIzN I FLANS "IF DERSON CREEK TOWNSHIP )F CAMERON, 1 HARNETT % \X,\ 76 -M, . .. ...... Z t % % N NOTTOSCALE A t- F, Fl- -0111 A. EXISTING UTILITY -INDEX - WATER AND S G1.0 PROJECT H C D P U C1.0 - EXISTING J, 7 . ...... ... . N 700 McKinney Parkway SIT GF C2.0 Lillington, North Carolina 27546 C3.0 - UTILITY IN"""'I'l",,.,P 910-893-7575 Contact- Shane Cummings C4.0 - C4.1 PRi C5.0 -SITE & EF C5.1 -WATER D rm C5.2 -SEWER B CAROLINA A01' NuRTH BOUNTY DRAWINGS NOTES CONDITIONS LADING PLAN 'LAN .............. .... . ........ JFILES--- .. . . ......... i� 10S.-I.-ON CONTROL DETAILS N C5.3 - STORM DETAILS ® ®.•.• ®•• °.° ° ® ®.•.• ®•• °.° ° Know what's beI1ow..,.,.,.,.,. SO S S m AL 0274 57 IN t.p SU C111 before you dig. "1ij,,v,, R S N F, na Al k CIVIL, ENGINEER OWNER/DEVELOPER rr. SURVEYOR !A 4D SITE SOLUTIONS INC. ODELL A. SMITH PROPERTIES LLC. D SITE SOLUTIONS INC. 409 Chicago Drive -Suite 112 400 Odell Road 409 Chicago Drive Suite 112 N Fayetteville, North Qarolina 28306 Spring Lake, North Carolina 28390 w nv Fayetteville, North Carolina 28306 910-426-6777 910-497-2020 w w w 910-426-6777 Jimmy Holland, PLS Scott Brown, PE Contact: Ken Smith Contact. --0.ontact. email. sbrown@4dsitesolutions.com email-,,,,odelIsmithco@embarqmail.com nw -em jholland@4dsitesolutions.com N THE CONTRACTOR MUST CONTACT NORTH CAROLINA ONE CALL CENTER AT 1-800-632-4949 A MINIMUM OF 48 HOURS PRIOR70, DIGGIN=G IN ORDER TO HAVE THE EXISTING UTILITIES LOCATED 409 Chicago Drive —5uife 112 fayeffe Le, Norih Carolina 28506 Phone: (gio) 426-6777 Fax: (gio) 426-5777 License Number: C-2554 4P T L bOLUTIONb, INC A L NqNE L P—ING A A, GP-') A, C,1N-')TP—L1CF10N LAYILIT A REVISIONS PROJECT NAME FOREST RIDGE ACCESS & UTILITY ROAD MELODY LANE ANDERSON CREEK TOWNSHIP TOWN OF CAMERON HARNETT COUNTY NORTH CAROLINA CLIENT ODELL A. SMITH PROPERTIES, LLC. 400 Odell Road Spring Lake, North Carolina 28390 Phone: (910) 497-2020 Fax: (910) 497-0569 PROJECT INFORMATION DESIGNED BY: BEN DRAWN BY: BEN CHECKED BY: SCOTT I PROJECT NUMBER: 512 DRAWING SCALE SEE SHEETS DATE RELEASED SEPTEMBER 27, 2012 73 N N 0 0 0 c UTILITY NOTES WATER 1. THE FIRE MARSHAL'S OFFICE SHALL APPROVE ALL HYDRANT TYPES AND LOCATIONS IN NEW SUBDIVISIONS. HOWEVER, HARNETT COUNTY DEPARTMENT OF PUBLIC UTILITIES (HCDPU) PREFERS THE CONTRACTORS TO INSTALL ONE OF THE FOLLOWING FIRE HYDRANTS: 1. MUELLER - SUPER CENTURION 250 A -423 MODEL WITH A 5%" MAIN VALVE OPENING THREE WAY (TWO HOSE NOZZLES AND ONE PUMPER NOZZLE); 2. AMERICAN DARLING - MARK B -84 -B MODEL WITH A 5%" MAIN VALVE OPENING THREE WAY (TWO HOSE NOZZLES AND ONE PUMPER NOZZLE); 3. WATEROUS - PACER B -67 -250 MODEL WITH A 5%" MAIN VALVE OPENING THREE WAY (TWO HOSE NOZZLES AND ONE PUMPER NOZZLE) OR APPROVED EQUAL FOR STANDARDIZATION. 2. FIRE HYDRANTS ARE INSTALLED AT CERTAIN ELEVATIONS. ANY GRADE CHANGE IN THE VICINITY OF ANY FIRE HYDRANT WHICH IMPEDES ITS OPERATION SHALL BECOME THE RESPONSIBILITY OF THE UTILITY CONTRACTOR FOR CORRECTION. CORRECTIONS WILL BE MONITORED BY THE HCDPU UTILITY CONSTRUCTION INSPECTOR AND THE HARNETT COUNTY FIRE MARSHAL. 3. THE PROFESSIONAL ENGINEER (PE) SHALL OBTAIN AND PROVIDE THE NCDENR "AUTHORIZATION TO CONSTRUCT" PERMIT TO THE UTILITY CONTRACTOR BEFORE THE CONSTRUCTION OF THE WATER LINE SHALL BEGIN. THE UTILITY CONTRACTOR MUST POST A COPY OF THE NCDENR "AUTHORIZATION TO CONSTRUCT" PERMIT ISSUED BY THE NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES - DIVISION OF ENVIRONMENTAL HEALTH, PUBLIC WATER SUPPLY SECTION (NCDENR- DEH,PWSS) ON SITE PRIOR TO THE START OF CONSTRUCTION. THE PERMIT MUST BE MAINTAINED ON SITE THROUGHOUT THE ENTIRE CONSTRUCTION PROCESS OF THE PROPOSED WATER LINES THAT WILL SERVE THIS PROJECT. 4. THE UTILITY CONTRACTOR SHALL NOTIFY HARNETT COUNTY DEPARTMENT OF PUBLIC UTILITIES (HCDPU) AND THE PROFESSIONAL ENGINEER (PE) AT LEAST TWO DAYS PRIOR TO CONSTRUCTION COMMENCING. THE UTILITY CONTRACTOR MUST SCHEDULE A PRE - CONSTRUCTION CONFERENCE WITH MR. ALAN MOSS, HCDPU UTILITY CONSTRUCTION INSPECTOR AT LEAST TWO (2) DAYS BEFORE CONSTRUCTION WILL BEGIN AND THE UTILITY CONTRACTOR MUST COORDINATE WITH HCDPU FOR REGULAR INSPECTION VISITATIONS AND ACCEPTANCE OF THE WATER SYSTEM(S). CONSTRUCTION WORK SHALL BE PERFORMED ONLY DURING THE NORMAL WORKING HOURS OF HCDPU WHICH IS 8:00 AM - 5:00 PM MONDAY THROUGH FRIDAY. HOLIDAY AND WEEKEND WORK IS NOT PERMITTED BY HCDPU. 5. THE PROFESSIONAL ENGINEER (PE) SHALL PROVIDE HCDPU AND THE UTILITY CONTRACTOR WITH A SET OF NCDENR APPROVED PLANS MARKED 'RELEASED FOR CONSTRUCTION" AT LEAST TWO DAYS PRIOR TO CONSTRUCTION COMMENCING. THE REGISTERED LAND SURVEYOR (RLS) SHOULD STAKE OUT ALL LOT CORNERS AND THE GRADE STAKES FOR THE PROPOSED FINISH GRADE FOR EACH STREET BEFORE THE UTILITY CONTRACTOR BEGINS CONSTRUCTION OF THE WATER LINE(S). THE GRADE STAKES SHOULD BE SET WITH A CONSISTENT OFFSET FROM THE STREET CENTERLINE SO AS NOT TO INTERFERE WITH THE STREET GRADING AND UTILITY CONSTRUCTION. 6. THE UTILITY CONTRACTOR SHALL PROVIDE THE HCDPU UTILITY CONSTRUCTION INSPECTOR WITH MATERIAL SUBMITTALS AND SHOP DRAWINGS FOR ALL PROJECT MATERIALS PRIOR TO THE CONSTRUCTION OF ANY WATER LINE EXTENSION(S), AND ASSOCIATED WATER SERVICES IN HARNETT COUNTY. THE MATERIALS TO BE USED ON THE PROJECT MUST MEET THE ESTABLISHED SPECIFICATIONS OF HCDPU AND BE APPROVED BY THE ENGINEER OF RECORD PRIOR TO CONSTRUCTION. ALL SUBSTANDARD MATERIALS OR MATERIALS NOT APPROVED FOR USE IN HARNETT COUNTY FOUND ON THE PROJECT SITE MUST BE REMOVED IMMEDIATELY WHEN NOTIFIED BY THE HCDPU UTILITY CONSTRUCTION INSPECTOR. 7. THE WATER MAIN(S), FIRE HYDRANTS, SERVICE LINES, METER SETTERS AND ALL ASSOCIATED APPURTENANCES SHALL BE CONSTRUCTED IN STRICT IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS OF THE HARNETT COUNTY DEPARTMENT OF PUBLIC UTILITIES (HCDPU). THE UTILITY CONTRACTOR SHALL BE RESPONSIBLE TO LOCATE THE NEWLY INSTALLED WATER MAIN(S), WATER SERVICE LINES AND ALL ASSOCIATED METER SETTERS AND METER BOXES FOR OTHER UTILITY COMPANIES AND THEIR CONTRACTORS UNTIL THE NEW WATER MAIN(S) HAVE BEEN APPROVED BY THE NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES - DIVISION OF ENVIRONMENTAL HEALTH, PUBLIC WATER SUPPLY SECTION (NCDENR -DEH, PWSS)AND ACCEPTED BY HCDPU. 8. PRIOR TO ACCEPTANCE, ALL SERVICES WILL BE INSPECTED TO INSURE THAT THEY ARE INSTALLED AT THE PROPER DEPTH. ALL METER BOXES MUST BE FLUSH WITH THE GROUND LEVEL AT FINISH GRADE AND THE METER SETTERS MUST BE A MINIMUM OF 8" BELOW THE METER BOX LID. METER SETTERS SHALL BE CENTERED IN THE METER BOX AND SUPPORTED BY BRICK, BLOCK OR STONE. 9. THE UTILITY CONTRACTOR SHALL PROVIDE THE PROFESSIONAL ENGINEER (PE) AND HCDPU UTILITY CONSTRUCTION INSPECTOR WITH A SET OF RED LINE DRAWINGS IDENTIFYING THE COMPLETE WATER SYSTEM INSTALLED FOR EACH PROJECT. THE RED LINE DRAWINGS SHOULD IDENTIFY THE MATERIALS, PIPE SIZES AND APPROXIMATE DEPTHS OF THE WATER LINES AS WELL AS THE GATE VALVES, FIRE HYDRANTS, METER SETTERS, BLOW OFF ASSEMBLIES AND ALL ASSOCIATED APPURTENANCES FOR ALL WATER LINE(S) CONSTRUCTED IN HARNETT COUNTY. THE RED LINE DRAWINGS SHOULD CLEARLY IDENTIFY ANY DEVIATIONS FROM THE NCDENR APPROVED PLANS. ALL CHANGE ORDERS MUST BE APPROVED BY HCDPU AND THE PROFESSIONAL ENGINEER (PE) IN WRITING AND PROPERLY DOCUMENTED IN THE RED LINE FIELD DRAWINGS. 10. POTABLE WATER MAINS CROSSING OTHER UTILITIES AND NON- POTABLE WATER LINES (SANITARY SEWER, STORM SEWER, RCP, ETC.) SHALL BE LAID TO PROVIDE A MINIMUM VERTICAL DISTANCE OF TWENTY -FOUR (24 ") INCHES BETWEEN THE POTABLE WATER MAIN AND ALL OTHER UTILITIES. NCDOT REQUIRES THE NEW WATER MAINS TO BE INSTALLED UNDER THE STORM WATER LINES. THE POTABLE WATER MAIN SHALL BE INSTALLED WITH TWENTY -FOUR (24 ") INCHES OF VERTICAL SEPARATION AND WITH DUCTILE IRON PIPE WHEN DESIGNED TO BE PLACED UNDER A NON- POTABLE WATER LINE SUCH AS SANITARY SEWER OR STORM SEWER LINES. IF THESE SEPARATIONS CANNOT BE MAINTAINED THEN THE WATER MAIN SHALL BE INSTALLED WITH DUCTILE IRON PIPE. BOTH THE POTABLE WATER MAIN AND THE NON- POTABLE WATER LINE MUST BE CAST IRON OR DUCTILE IRON PIPE (DIP) IF THE STATE MINIMUM SEPARATIONS CANNOT BE MAINTAINED. THE DUCTILE IRON PIPE MUST BE LAID SO THE MECHANICAL JOINTS ARE AT LEAST (10') FEET FROM THE POINT WHERE THE POTABLE WATER MAIN CROSSES THE NON- POTABLE WATER LINE. 11. POTABLE WATER MAINS INSTALLED PARALLEL TO NON- POTABLE WATER LINES (SANITARY SEWER, STORM SEWER, RCP, ETC.) SHALL BE LAID TO PROVIDE A MINIMUM HORIZONTAL DISTANCE OF TEN (10') FEET BETWEEN THE POTABLE WATER MAIN AND SANITARY SEWER MAINS, SEWER LATERALS AND SERVICES. THE HORIZONTAL SEPARATION BETWEEN THE POTABLE WATER MAIN AND ANY OTHER UTILITY OR STORM SEWER SHALL NOT BE LESS THAN FIVE (5) FEET. THE POTABLE WATER MAIN MUST BE DUCTILE IRON PIPE IF THIS HORIZONTAL SEPARATION OF TEN (10') FEET CANNOT BE MAINTAINED. THE DUCTILE IRON PIPE SHALL EXTEND AT LEAST TEN (10') FEET BEYOND THE POINT WHERE THE MINIMUM REQUIRED HORIZONTAL SEPARATION OF TEN (10') FEET CAN BE RE- ESTABLISHED. 12. METER SETTERS SHALL BE INSTALLED IN PAIRS ON EVERY OTHER LOT LINE WHERE POSSIBLE TO LEAVE ADEQUATE SPACE FOR OTHER UTILITIES TO BE INSTALLED AT A LATER TIME. THE METER SETTERS SHALL BE INSTALLED AT LEAST ONE (1') FOOT INSIDE THE RIGHT -OF -WAY AND AT LEAST THREE (3') TO FIVE (5) FEET FROM THE PROPERTY LINE BETWEEN THE LOTS. 13. HCDPU REQUIRES THAT METER BOXES FOR 3 /a " SERVICES SHALL BE 12" WIDE X 17" LONG ABS PLASTIC BOXES AT LEAST 18" IN HEIGHT WITH CAST IRON LIDS /COVERS. METER BOXES FOR 1" SERVICES SHALL BE 17" WIDE X 21" LONG ABS PLASTIC BOXES AT LEAST 18" IN HEIGHT WITH PLASTIC LIDS AND CAST IRON FLIP COVERS IN THE CENTER OF THE LIDS. METER BOXES FOR 2" SERVICES SHALL BE 20" WIDE X 32" LONG ABS PLASTIC BOXES AT LEAST 20" IN HEIGHT WITH PLASTIC LIDS AND CAST IRON FLIP COVERS IN THE CENTER OF THE LIDS. 14. MASTER METERS MUST BE INSTALLED IN CONCRETE VAULTS SIZED FOR THE METER ASSEMBLY AND ASSOCIATED APPURTENANCES SO AS TO PROVIDE AT LEAST EIGHTEEN (18 ") INCHES OF CLEARANCE BETWEEN THE BOTTOM OF THE CONCRETE VAULT AND THE BOTTOM OF THE METER SETTER. THE MASTER METER MUST BE PROVIDED TEST PORTS IF THE METER IS NOT EQUIPPED WITH TEST PORTS FROM THE MANUFACTURER IN ACCORDANCE WITH THE HCDPU ESTABLISHED STANDARD SPECIFICATIONS AND DETAILS. DUCTILE IRON PIPE MUST BE USED FOR THE MASTER METER VAULT PIPING AND VALVE VAULT PIPING. THE UTILITY CONTRACTOR MUST PROVIDE SHOP DRAWINGS FOR THE METER VAULTS TO HCDPU PRIOR TO ORDERING THE CONCRETE VAULTS. 15. THE UTILITY CONTRACTOR WILL INSTALL POLYETHYLENE SDR -9 WATER SERVICE LINES THAT CROSS UNDER THE PAVEMENT INSIDE A SCHEDULE 40 PVC CONDUIT TO ALLOW FOR REMOVAL AND REPLACEMENT IN THE FUTURE. TWO (2) INDEPENDENT m," WATER SERVICE LINES MAY BE INSTALLED INSIDE ONE (1) - TWO (2 ") INCH SCHEDULE 40 PVC CONDUIT OR TWO (2) INDEPENDENT 1" WATER SERVICE LINES MAY BE INSTALLED INSIDE ONE (1) - THREE (3 ") INCH SCHEDULE 40 PVC CONDUIT, BUT EACH WATER SERVICE SHALL BE TAPPED DIRECTLY TO THE WATER MAIN. SPLIT SERVICES ARE NOT ALLOWED BY HCDPU. 16. THE WATER MAIN(S), FIRE HYDRANTS, GATE VALVES, SERVICE LINES, METER SETTERS AND ASSOCIATED APPURTENANCES MUST BE RATED FOR 200 PSI AND HYDROSTATICALLY PRESSURE TESTED TO 200 PSI. THE HYDROSTATIC PRESSURE TEST(S) MUST BE WITNESSED BY THE HCDPU UTILITY CONSTRUCTION INSPECTOR. THE UTILITY CONTRACTOR MUST NOTIFY HCDPU WHEN THEY ARE READY TO BEGIN FILLING IN LINES AND COORDINATE WITH HARNETT COUNTY TO WITNESS ALL PRESSURE TESTING. 17. THE UTILITY CONTRACTOR SHALL CONDUCT A PNEUMATIC PRESSURE TEST USING COMPRESSED AIR OR OTHER INERT GAS ON THE STAINLESS STEEL TAPPING SLEEVE(S) PRIOR TO MAKING THE TAP ON THE EXISTING WATER MAIN. THIS PNEUMATIC PRESSURE TEST MUST BE WITNESSED BY THE HCDPU UTILITY CONSTRUCTION INSPECTOR. THE UTILITY CONTRACTOR SHALL USE ROMAC BRAND STAINLESS STEEL TAPPING SLEEVE(S) OR APPROVED EQUAL FOR ALL TAPS MADE IN HARNETT COUNTY. ALL NEW WATER LINE EXTENSIONS MUST BEGIN WITH A RESILIENT WEDGE TYPE GATE VALVE SIZED EQUAL TO THE DIAMETER OF THE NEW WATER LINE EXTENSION IN ORDER TO PROVIDE A MEANS OF ISOLATION BETWEEN HARNETT COUNTY'S EXISTING WATER MAINS AND THE NEW WATER LINE EXTENSIONS UNDER CONSTRUCTION. 18. ALL WATER MAINS WILL BE CONSTRUCTED WITH SDR -21 PVC PIPE OR CLASS 50 DUCTILE IRON PIPE RATED FOR AT LEAST 200 PSI OR GREATER. ALL PIPES MUST BE PROTECTED DURING LOADING, TRANSPORT, UNLOADING, STAGING, AND INSTALLATION. PVC PIPE MUST BE PROTECTED FROM EXTENDED EXPOSURE TO SUNLIGHT PRIOR TO INSTALLATION. 19. ALL WATER MAINS WILL BE FLUSHED AND DISINFECTED IN STRICT ACCORDANCE WITH THE STANDARD SPECIFICATIONS OF THE HARNETT COUNTY DEPARTMENT OF PUBLIC UTILITIES. ALL WATER SAMPLES COLLECTED FOR BACTERIA TESTING WILL BE COLLECTED BY THE HCDPU UTILITY CONSTRUCTION INSPECTOR AND TESTED IN THE HCDPU LABORATORY. 20. ALL FITTINGS LARGER THAN TWO (2 ") INCHES DIAMETER SHALL BE DUCTILE IRON. HCDPU REQUIRES THAT MECHANICAL JOINTS BE ASSEMBLED WITH GRIP RINGS AS "MEGALUG" FITTINGS ARE NOT APPROVED BY HARNETT COUNTY FOR PIPE SIZES SMALLER THAN TWELVE INCHES (12 ") DIAMETER. PVC PIPE USED FOR WATER MAINS SHALL BE CONNECTED BY SLIP JOINT OR MECHANICAL JOINT WITH GRIP RINGS. GLUED PIPE JOINTS ARE NOT ALLOWED ON PVC PIPE USED FOR WATER MAINS IN HARNETT COUNTY. 21. HCDPU REQUIRES THAT THE UTILITY CONTRACTOR INSTALL TRACER WIRE IN THE TRENCH WITH ALL WATER LINES. THE TRACER WIRE SHALL BE 12 GA. INSULATED, SOLID COPPER CONDUCTOR AND IT SHALL BE TERMINATED AT THE TOP OF THE VALVE BOXES OR MANHOLES. NO SPLICED WIRE CONNECTIONS SHALL BE MADE UNDERGROUND ON TRACER WIRE INSTALLED IN HARNETT COUNTY. THE TRACER WIRE MAY BE SECURED WITH DUCT TAPE TO THE TOP OF THE PIPE BEFORE BACKFILLING. 22. THE UTILITY CONTRACTOR WILL PROVIDE PROFESSIONAL ENGINEER (PE) AND THE HCDPU UTILITY CONSTRUCTION INSPECTOR WITH A SET OF RED LINE FIELD DRAWINGS TO IDENTIFY THE INSTALLED LOCATIONS OF THE WATER LINE(S) AND ALL ASSOCIATED SERVICES. ALL CHANGE ORDERS MUST BE PRE - APPROVED BY HCDPU AND THE PROFESSIONAL ENGINEER (PE) IN WRITING AND PROPERLY DOCUMENTED IN THE RED LINE FIELD DRAWINGS. 23. THE UTILITY CONTRACTOR SHALL SPOT DIG TO EXPOSE EACH UTILITY PIPE OR LINE WHICH MAY CONFLICT WITH CONSTRUCTION OF PROPOSED WATER LINE EXTENSIONS WELL IN ADVANCE TO VERIFY LOCATIONS OF THE EXISTING UTILITIES. THE UTILITY CONTRACTOR SHALL PROVIDE BOTH HORIZONTAL AND VERTICAL CLEARANCES TO THE PROFESSIONAL ENGINEER (PE) TO ALLOW THE PE TO ADJUST THE WATER LINE DESIGN IN ORDER TO AVOID CONFLICTS WITH EXISTING UNDERGROUND UTILITIES. THE UTILITY CONTRACTOR SHALL COORDINATE WITH THE UTILITY OWNER AND BE RESPONSIBLE FOR TEMPORARY RELOCATION AND /OR SECURING EXISTING UTILITY POLES, PIPES, WIRES, CABLES, SIGNS AND /OR UTILITIES INCLUDING SERVICES IN ACCORDANCE WITH THE UTILITY OWNER REQUIREMENTS DURING WATER LINE INSTALLATION, GRADING AND STREET CONSTRUCTION. 24. PRIOR TO THE COMMENCEMENT OF ANY WORK WITHIN ESTABLISHED UTILITY EASEMENTS OR NCDOT RIGHT -OF -WAYS THE UTILITY CONTRACTOR IS REQUIRED TO HAVE A SIGNED NCDOT ENCROACHMENT AGREEMENT POSTED ON SITE AND NOTIFY ALL CONCERNED UTILITY COMPANIES IN ACCORDANCE WITH G.S. 87 -102. THE UTILITY CONTRACTOR MUST CALL THE NC ONE CALL CENTER AT 811 OR (800) 632 -4949 TO VERIFY THE LOCATION OF EXISTING UTILITIES PRIOR TO THE BEGINNING OF CONSTRUCTION. EXISTING UTILITIES SHOWN IN THESE PLANS ARE TAKEN FROM MAPS FURNISHED BY VARIOUS UTILITY COMPANIES AND HAVE NOT BEEN PHYSICALLY LOCATED OR VERIFIED BY THE P.E. (I.E. TELEPHONE, CABLE, WATER, SEWER, ELECTRICAL POWER, FIBER OPTIC, NATURAL GAS, ETC.). THE UTILITY CONTRACTOR WILL BE RESPONSIBLE TO REPAIR ANY AND ALL DAMAGES TO THE SATISFACTION OF THE RELATED UTILITY COMPANY. 25. Y. THE UTILITY CONTRACTOR SHALL PROVIDE HCDPU WITH AT LEAST ONE (1) FIRE HYDRANT WRENCH AND ONE (1) BREAK -AWAY FLANGE KIT FOR EVERY SUBDIVISION WITH FIRE HYDRANTS DEVELOPED IN HARNETT COUNTY. THESE ITEMS MUST BE PROVIDED TO HCDPU BEFORE THE FINAL INSPECTION WILL BE SCHEDULED BY THE HCDPU UTILITY CONSTRUCTION INSPECTOR. IN ADDITION, THE UTILITY CONTRACTOR SHALL INSTALL A 4" X 4" CONCRETE VALVE MARKER AT THE EDGE OF THE RIGHT -OF -WAY TO IDENTIFY THE LOCATION OF EACH GATE VALVE INSTALLED IN THE NEW WATER SYSTEM WITH THE EXCEPTION OF THE FIRE HYDRANT ISOLATION VALVES. THE CONTRACTOR SHALL MEASURE THE DISTANCE FROM THE CENTER OF THE CONCRETE MARKER TO THE CENTER OF THE VALVE BOX. THIS DISTANCE (IN LINEAR FEET) SHALL BE STAMPED ON THE BRASS PLATE LOCATED ON THE TOP OF THE CONCRETE VALVE MARKER. IN LIEU OF INSTALLING THE CONCRETE VALVE MARKERS, THE UTILITY CONTRACTOR MAY PROVIDE AT LEAST TWO MEASUREMENTS FROM TWO INDEPENDENT PERMANENT ABOVE GROUND STRUCTURES TO THE PROFESSIONAL ENGINEER (PE) IN THE RED LINE DRAWINGS TO IDENTIFY THE VALVE LOCATIONS. THE PROFESSIONAL ENGINEER (PE) MUST INCLUDE THESE MEASUREMENTS IN THE AS -BUILT RECORD DRAWINGS SUBMITTED TO HCDPU. 26. Z. THE UTILITY CONTRACTOR WILL BE RESPONSIBLE FOR ANY AND ALL REPAIRS DUE TO LEAKAGE DAMAGE FROM POOR WORKMANSHIP DURING THE ONE (1) YEAR WARRANTY PERIOD ONCE THE WATER SYSTEM IMPROVEMENTS HAVE BEEN ACCEPTED BY HARNETT COUNTY. HARNETT COUNTY WILL PROVIDE MAINTENANCE AND REPAIRS WHEN REQUESTED AND BILL THE DEVELOPER AND /OR UTILITY CONTRACTOR IF NECESSARY DUE TO LACK OF RESPONSE WITHIN 48 HOURS OF NOTIFICATION OF WARRANTY WORK. THE UTILITY CONTRACTOR WILL BE RESPONSIBLE FOR ANY AND ALL REPAIRS DUE TO DAMAGES RESULTING FROM FAILURE TO LOCATE THE NEW WATER LINES AND ASSOCIATED APPURTENANCES FOR OTHER UTILITIES AND THEIR CONTRACTORS UNTIL THE WATER LINES HAVE BEEN APPROVED BY NCDENR AND ACCEPTED BY HCDPU. THE FINAL INSPECTION OF WATER SYSTEM IMPROVEMENTS CANNOT BE SCHEDULED WITH HCDPU UNTIL THE STREETS HAVE BEEN PAVED, THE RIGHTS -OF -WAY AND UTILITY EASEMENTS HAVE BEEN SEEDED AND STABILIZED WITH AN ADEQUATE STAND OF GRASS IN PLACE TO PREVENT EROSION ISSUES ON SITE. 27. AA THE ENGINEER OF RECORD IS RESPONSIBLE TO INSURE THAT CONSTRUCTION IS, AT ALL TIMES, IN COMPLIANCE WITH ACCEPTED SANITARY ENGINEERING PRACTICES AND APPROVED PLANS AND SPECIFICATIONS. NO FIELD CHANGES TO THE APPROVED PLANS ARE ALLOWED WITHOUT PRIOR WRITTEN APPROVAL BY HCDPU. A COPY OF EACH ENGINEER'S FIELD REPORT IS TO BE SUBMITTED TO HCDPU AS EACH SUCH INSPECTION IS MADE ON SYSTEM IMPROVEMENTS OR TESTING IS PERFORMED BY THE CONTRACTOR. WATER AND SEWER INFRASTRUCTURE MUST PASS ALL TESTS REQUIRED BY HCDPU SPECIFICATIONS AND THOSE OF ALL APPLICABLE REGULATORY AGENCIES. THESE TESTS INCLUDE, BUT ARE NOT LIMITED TO: AIR TEST, VACUUM TEST, MANDREL TEST, VISUAL TEST, PRESSURE TEST, BACTERIOLOGICAL TEST, ETC. A HCDPU INSPECTOR MUST BE PRESENT DURING TESTING AND ALL TEST RESULTS SHALL BE SUBMITTED TO HCDPU. ALL TESTS MUST BE SATISFIED BEFORE THE FINAL INSPECTION WILL BE SCHEDULED WITH THE HCDPU INSPECTOR. THE ENGINEER OF RECORD MUST REQUEST IN WRITING TO SCHEDULE THE FINAL INSPECTION ONCE ALL CONSTRUCTION IS COMPLETE. THE DEVELOPER'S ENGINEER OF RECORD AND THE HCDPU UTILITY CONSTRUCTION INSPECTOR SHALL PREPARE A WRITTEN PUNCH LIST OF ANY DEFECTS OR DEFICIENCIES NOTED DURING THE FINAL INSPECTION, SHOULD ANY EXIST. UPON COMPLETION OF THE PUNCH LIST, THE DEVELOPER'S ENGINEER OF RECORD WILL SCHEDULE ANOTHER INSPECTION. IN THE EVENT THE NUMBER OF INSPECTIONS PERFORMED BY THE HCDPU EXCEEDS TWO, ADDITIONAL FEES MAY BE ACCESSED TO THE DEVELOPER. SANITARY SEWER 1. THE PROFESSIONAL ENGINEER (PE) SHALL OBTAIN AND SUPPLY A COPY OF THE SEWER PERMIT FOR THE CONSTRUCTION AND OPERATION OF THE WASTEWATER COLLECTION SYSTEM TO THE UTILITY CONTRACTOR BEFORE THE CONSTRUCTION OF THE SANITARY SEWER LINE, SEWER LIFT STATION AND ASSOCIATED FORCE MAIN SHALL BEGIN. THE UTILITY CONTRACTOR MUST POST A COPY OF THE SEWER PERMIT ISSUED BY THE NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES - DIVISION OF WATER QUALITY (NCDENR -DWQ) ON SITE PRIOR TO THE START OF CONSTRUCTION. THE PERMIT MUST BE MAINTAINED ON SITE DURING THE CONSTRUCTION OF THE SEWER SYSTEM IMPROVEMENTS. 2. THE UTILITY CONTRACTOR SHALL NOTIFY HARNETT COUNTY DEPARTMENT OF PUBLIC UTILITIES (HCDPU) AND THE PROFESSIONAL ENGINEER (PE) AT LEAST TWO DAYS PRIOR TO CONSTRUCTION COMMENCING. THE UTILITY CONTRACTOR MUST SCHEDULE A PRE - CONSTRUCTION CONFERENCE WITH MR. ALAN MOSS, HCDPU UTILITY CONSTRUCTION INSPECTOR AT LEAST TWO (2) DAYS BEFORE CONSTRUCTION WILL BEGIN AND THE UTILITY CONTRACTOR MUST COORDINATE WITH HCDPU FOR REGULAR INSPECTION VISITATIONS AND ACCEPTANCE OF THE WASTEWATER SYSTEM(S). CONSTRUCTION WORK SHALL BE PERFORMED ONLY DURING THE NORMAL WORKING HOURS OF HCDPU WHICH IS 8:00 AM - 5:00 PM MONDAY THROUGH FRIDAY. HOLIDAY AND WEEKEND WORK IS NOT PERMITTED BY HCDPU. 3. THE PROFESSIONAL ENGINEER (PE) SHALL PROVIDE HCDPU WITH A SET OF NCDENR APPROVED PLANS MARKED "RELEASED FOR CONSTRUCTION" AT LEAST TWO DAYS PRIOR TO CONSTRUCTION COMMENCING. HCDPU WILL STAMP THE APPROVED PLANS AS "RELEASED FOR CONSTRUCTION" AND PROVIDE COPIES TO THE UTILITY CONTRACTOR. THE REGISTERED LAND SURVEYOR (RLS) SHALL STAKE OUT ALL LOT CORNERS AND ESTABLISH GRADE STAKES FOR THE PROPOSED FINISH GRADE FOR EACH STREET AND SEWER LINE BEFORE THE UTILITY CONTRACTOR BEGINS CONSTRUCTION OR INSTALLATION OF THE MANHOLES, SANITARY SEWER GRAVITY LINE(S), SEWER LIFT STATIONS AND /OR SANITARY SEWER FORCE MAIN(S). THE GRADE STAKES SHOULD BE SET WITH A CONSISTENT OFFSET FROM THE STREET CENTERLINE SO AS NOT TO INTERFERE WITH THE STREET GRADING OR UTILITY CONSTRUCTION. 4. THE UTILITY CONTRACTOR SHALL PROVIDE THE HCDPU UTILITY CONSTRUCTION INSPECTOR WITH MATERIAL SUBMITTALS AND SHOP DRAWINGS FOR ALL PROJECT MATERIALS PRIOR TO THE CONSTRUCTION OF ANY GRAVITY SEWER LINE(S), MANHOLE(S), SEWER LIFT STATION(S) AND ASSOCIATED FORCE MAIN(S) IN HARNETT COUNTY. THE MATERIALS TO BE USED ON THE PROJECT MUST MEET THE ESTABLISHED SPECIFICATIONS OF HCDPU AND BE APPROVED BY THE ENGINEER OF RECORD PRIOR TO CONSTRUCTION. ALL SUBSTANDARD MATERIALS OR MATERIALS NOT APPROVED FOR USE IN HARNETT COUNTY FOUND ON THE PROJECT SITE MUST BE REMOVED IMMEDIATELY WHEN NOTIFIED BY THE HCDPU UTILITY CONSTRUCTION INSPECTOR. 5. THE SANITARY SEWER LATERAL CONNECTIONS SHOULD BE INSTALLED 90° (PERPENDICULAR) TO THE SANITARY SEWER GRAVITY LINES WITH SCHEDULE 40 PVC PIPE. HCDPU REQUIRES THE UTILITY CONTRACTOR TO PROVIDE THE PROFESSIONAL ENGINEER (PE) WITH ACCURATE MEASUREMENTS FOR LOCATING SANITARY SEWER SERVICE LATERAL AND ASSOCIATED EACH SANITARY SEWER CLEAN -OUT. THESE MEASUREMENTS SHOULD BE TAKEN FROM THE NEAREST DOWNSTREAM MANHOLE UP ALONG THE SANITARY SEWER MAIN TO THE IN -LINE WYE FITTING (OR TAPPING SADDLE) AND THEN ANOTHER MEASUREMENT FROM THE IN -LINE WYE FITTING (OR TAPPING SADDLE) TO THE 4" X 4" LONG SWEEP COMBINATION WYE FITTING AT THE BOTTOM OF THE SEWER CLEAN -OUT STACK. THESE FIELD MEASUREMENTS MUST BE PROVIDED TO THE PROFESSIONAL ENGINEER (PE) IN THE RED LINE DRAWINGS FROM THE UTILITY CONTRACTOR FOR PROPER DOCUMENTATION IN THE AS -BUILT RECORD DRAWINGS SUBMITTED TO HCDPU. 6. THE UTILITY CONTRACTOR SHALL BE RESPONSIBLE TO LOCATE THE NEWLY INSTALLED SANITARY SEWER GRAVITY LINE(S), SANITARY SEWER FORCE MAIN(S), SANITARY SEWER SERVICE LATERAL(S) AND ALL ASSOCIATED SEWER CLEAN- OUT(S) IN THE PROPOSED SANITARY SEWER SYSTEM FOR OTHER UTILITY COMPANIES AND THEIR CONTRACTORS UNTIL THE NEW SANITARY SEWER LINE(S) AND ASSOCIATED APPURTENANCES HAVE BEEN APPROVED BY THE NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES - DIVISION OF WATER QUALITY (NCDENR -DWQ) AND ACCEPTED BY HCDPU. ALL NEW SANITARY SEWER LINES MUST HAVE AT LEAST THREE (3 FT. ) FEET OF COVER AND EXTEND UNDER ALL EXISTING WATER MAIN AND STORM WATER LINES WITH A LEAST 24" OF VERTICAL CLEARANCE BELOW THE BOTTOM OF THE EXISTING WATER MAIN AND STORM WATER LINES. 7. THE SANITARY SEWER GRAVITY LINE(S), MANHOLE(S), SANITARY SEWER SERVICE LATERAL(S) AND ASSOCIATED CLEAN- OUT(S) SHALL BE CONSTRUCTED IN STRICT ACCORDANCE WITH THE STANDARD SPECIFICATIONS OF THE HARNETT COUNTY DEPARTMENT OF PUBLIC UTILITIES. THE SANITARY SEWER GRAVITY LINE(S) MUST PNEUMATICALLY PRESSURE TESTED WITH COMPRESSED AIR AT 5 PSI AND THE SANITARY SEWER FORCE MAIN(S) MUST HYDROSTATICALLY PRESSURE TESTED WITH WATER OR AIR AT 200 PSI AND WITNESSED BY THE HCDPU UTILITY CONSTRUCTION INSPECTOR. 8. PRIOR TO ACCEPTANCE, ALL SEWER SERVICE LATERALS WILL BE INSPECTED TO INSURE THAT THEY ARE INSTALLED AT THE PROPER DEPTH. ALL SEWER CLEAN -OUTS MUST BE INSTALLED SO THE 4" X 4" LONG SWEEP COMBINATION WYE IS AT LEAST THREE (3') FEET BUT NO MORE THAN FOUR (4') FEET BELOW THE FINISH GRADE UNLESS OTHERWISE APPROVED IN WRITING BY HCDPU. THE SEWER CLEANOUTS SHALL HAVE A FOUR (4 ") SCHEDULE 40 PVC PIPE STUBBED UP FROM BOTH ENDS OF THE 4" X 4" LONG SWEEP COMBINATION WYE TO BE AT LEAST TWO (2') FEET ABOVE THE FINISH GRADE AND COVER EACH END WITH A FOUR (4 ") INCH TEMPORARY CAP TO KEEP OUT DIRT, SAND, ROCKS WATER AND CONSTRUCTION DEBRIS. THE VERTICAL STACK ON EACH CLEAN - OUT MUST BE PROVIDED WITH A CONCRETE DONUT FOR PROTECTION. 9. ONCE THE SANITARY SEWER GRAVITY LINE(S) HAVE BEEN INSTALLED, PNEUMATICALLY PRESSURE TESTED AND IN PLACE FOR AT LEAST 30 DAYS, THE UTILITY CONTRACTOR MUST CONTACT THE HCDPU UTILITY CONSTRUCTION INSPECTOR TO WITNESS THE MANDREL TEST ON EACH PVC SANITARY SEWER GRAVITY LINE. THE UTILITY CONTRACTOR WILL NOTIFY HCDPU TO SCHEDULE THE MANDREL TESTING. THE MANDREL AND PROVING RING MUST BE SUPPLIED BY THE UTILITY CONTRACTOR. CLOSED CIRCUIT VIDEO CAMERA INSPECTIONS (AT THE UTILITY CONTRACTOR'S EXPENSE) MAY BE REQUIRED BY THE HCDPU UTILITY CONSTRUCTION INSPECTOR IF THE MANDREL TESTING CANNOT BE COMPLETED WITH SATISFACTORY RESULTS. THE SANITARY SEWER LINES SHOULD BE FLUSHED CLEAN USING A SEWER BALL OF THE PROPER DIAMETER BEFORE ANY MANDREL TESTING CAN BE PERFORMED. THE UTILITY CONTRACTOR IS RESPONSIBLE TO REMOVE ALL DIRT, SAND, SILT, GRAVEL, MUD AND DEBRIS FROM THE NEWLY CONSTRUCTED SEWER LINES EXERCISING CARE TO KEEP THE HARNETT COUNTY'S EXISTING SANITARY SEWER SYSTEMS CLEAN. SANITARY SEWER FORCE MAIN(S) SHALL BE PRESSURE TESTED TO 200 PSI FOR AT LEAST 2 HOURS LIKE WATER LINES. 10. THE UTILITY CONTRACTOR SHALL BE RESPONSIBLE TO LOCATE THE NEWLY INSTALLED SANITARY SEWER SYSTEM(S) FOR OTHER UTILITY COMPANIES AND THEIR CONTRACTORS UNTIL THE NEW SANITARY SEWER SYSTEM(S) HAVE BEEN APPROVED BY THE NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES - DIVISION OF WATER QUALITY (NCDENR- DWQ)AND ACCEPTED BY HCDPU. 11. HCDPU REQUIRES THAT THE UTILITY CONTRACTOR INSTALL TRACER WIRE IN THE TRENCH WITH ALL SANITARY SEWER FORCE MAINS. THE TRACER WIRE SHALL BE 12 GA. INSULATED, SOLID COPPER CONDUCTOR AND IT SHALL BE TERMINATED AT THE TOP OF THE VALVE BOXES OR MANHOLES. NO SPLICED WIRE CONNECTIONS SHALL BE MADE UNDERGROUND ON TRACER WIRE INSTALLED IN HARNETT COUNTY. THE TRACER WIRE MAY BE SECURED WITH DUCT TAPE TO THE TOP OF THE PIPE BEFORE BACKFILLING. THE TRACER WIRE IS NOT REQUIRED FOR THE GRAVITY SEWER LINE(S) BETWEEN MANHOLES. 12. THE UTILITY CONTRACTOR SHALL PROVIDE THE PROFESSIONAL ENGINEER (PE) AND HCDPU UTILITY CONSTRUCTION INSPECTOR WITH A SET OF RED LINE DRAWINGS IDENTIFYING THE COMPLETE SEWER SYSTEM INSTALLED FOR EACH PROJECT. THE RED LINE DRAWINGS SHOULD IDENTIFY THE MATERIALS, PIPE SIZES AND APPROXIMATE DEPTHS OF THE SEWER LINES AS WELL AS THE INSTALLED LOCATIONS OF THE MANHOLE(S), SANITARY SEWER GRAVITY LINE(S), SANITARY SEWER SERVICE LATERALS, CLEAN -OUTS, SEWER LIFT STATION(S) AND ASSOCIATED FORCE MAIN(S). THE RED LINE DRAWINGS SHOULD CLEARLY IDENTIFY ANY DEVIATIONS FROM THE NCDENR APPROVED PLANS. ALL CHANGE ORDERS MUST BE APPROVED BY HCDPU AND THE PROFESSIONAL ENGINEER (PE) IN WRITING AND PROPERLY DOCUMENTED IN THE RED LINE FIELD DRAWINGS. 13. PRIOR TO THE COMMENCEMENT OF ANY WORK WITHIN ESTABLISHED UTILITY EASEMENTS OR NCDOT RIGHT -OF -WAYS THE UTILITY CONTRACTOR IS REQUIRED TO NOTIFY ALL CONCERNED UTILITY COMPANIES IN ACCORDANCE WITH G.S. 87 -102. THE UTILITY CONTRACTOR MUST CALL THE NC ONE CALL CENTER AT 811 OR (800) 632 -4949 TO VERIFY THE LOCATION OF EXISTING UTILITIES PRIOR TO THE BEGINNING OF CONSTRUCTION. EXISTING UTILITIES SHOWN IN THESE PLANS ARE TAKEN FROM MAPS FURNISHED BY VARIOUS UTILITY COMPANIES AND HAVE NOT BEEN PHYSICALLY LOCATED BY THE P.E. (I.E. TELEPHONE, CABLE, WATER, SEWER, ELECTRICAL POWER, FIBER OPTIC, NATURAL GAS, ETC.). 14. THE UTILITY CONTRACTOR SHALL SPOT DIG TO EXPOSE EACH EXISTING UTILITY PIPE OR LINE WHICH MAY CONFLICT WITH CONSTRUCTION OF PROPOSED SANITARY SEWER LINE EXTENSIONS WELL IN ADVANCE TO VERIFY LOCATIONS OF THE EXISTING UTILITIES. THE UTILITY CONTRACTOR SHALL PROVIDE BOTH HORIZONTAL AND VERTICAL CLEARANCES TO THE PROFESSIONAL ENGINEER (PE) TO ALLOW THE PE TO ADJUST THE SANITARY SEWER LINE DESIGN IN ORDER TO AVOID CONFLICTS WITH EXISTING UNDERGROUND UTILITIES. THE UTILITY CONTRACTOR SHALL COORDINATE WITH THE UTILITY OWNER AND BE RESPONSIBLE FOR TEMPORARY RELOCATION OF EXISTING UTILITIES AND /OR SECURING EXISTING UTILITY POLES, PIPES, WIRES, CABLES, SIGNS AND /OR UTILITIES INCLUDING SERVICES IN ACCORDANCE WITH THE UTILITY OWNER'S REQUIREMENTS DURING SANITARY SEWER LINE INSTALLATION, GRADING AND STREET CONSTRUCTION. 15. WHEN MAKING A TAP ON AN EXISTING SEWER FORCE MAIN, THE UTILITY CONTRACTOR MUST HAVE A PERMIT FROM THE NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES - DIVISION OF WATER QUALITY (NCDENR -DWQ) PRIOR TO BEGIN THE TAP WORK. THE UTILITY CONTRACTOR SHALL CONDUCT A PNEUMATIC PRESSURE TEST USING COMPRESSED AIR OR OTHER INERT GAS ON THE STAINLESS STEEL TAPPING SLEEVE AND GATE VALVE PRIOR TO MAKING THE TAP ON AN EXISTING SANITARY SEWER FORCE MAIN. THIS PNEUMATIC PRESSURE TEST MUST BE WITNESSED BY THE HCDPU UTILITY CONSTRUCTION INSPECTOR. THE UTILITY CONTRACTOR SHALL USE ROMAC BRAND STAINLESS STEEL TAPPING SLEEVE(S) OR APPROVED EQUAL FOR ALL TAPS MADE ON SANITARY SEWER FORCE MAINS IN HARNETT COUNTY. THE UTILITY CONTRACTOR SHALL USE ROMAC BRAND STYLE "CB" SEWER SADDLES WITH STAINLESS STEEL BANDS OR APPROVED EQUAL FOR ALL TAPS MADE ON EXISTING SANITARY SEWER GRAVITY LINES IN HARNETT COUNTY. 16. THE UTILITY CONTRACTOR SHALL PROVIDE A GREASE TRAP FOR EACH SANITARY SEWER SERVICE LATERAL THAT WILL BE CONNECTED TO A RESTAURANT, FOOD PROCESSING FACILITY AND ANY OTHER COMMERCIAL OR INDUSTRIAL FACILITY AS REQUIRED BY THE HARNETT COUNTY FAT, OIL & GREASE ORDINANCE. THE GREASE TRAP MUST BE RATED FOR A MINIMUM CAPACITY OF AT LEAST 1,000 GALLONS UNLESS OTHERWISE APPROVED IN WRITING BY THE HCDPU PRE - TREATMENT COORDINATOR. GARBAGE DISPOSALS SHOULD NOT BE INSTALLED IN HOMES AND BUSINESSES THAT DISCHARGE WASTEWATER TO THE HARNETT COUNTY SANITARY SEWER SYSTEM AS THEY ARE NOT APPROVED BY HCDPU. 17. EACH SEWER LIFT STATION MUST BE PROVIDED WITH THREE PHASE POWER (AT LEAST 480 VOLTS) AND CONSTRUCTED TO MEET THE MINIMUM REQUIREMENTS OF THE LATEST VERSION OF THE NATIONAL ELECTRICAL CODE (NEC) AND HARNETT COUNTY STANDARD SPECIFICATIONS AND DETAILS. IF THREE PHASE POWER IS NOT AVAILABLE FROM THE POWER COMPANY OTHER ARRANGEMENTS MUST BE APPROVED BY HCDPU ENGINEERING PRIOR TO THE START OF CONSTRUCTION. 18. WHERE A NEW SANITARY SEWER FORCE MAIN IS CONNECTED TO AN EXISTING MANHOLE IN THE HARNETT COUNTY SEWER COLLECTIONS SYSTEM, THE UTILITY CONTRACTOR MUST PROVIDE A PROTECTIVE COATING (COAL TAR EPDXY ) FOR THE INTERIOR SURFACES OF THE MANHOLE TO PROTECT IT AGAINST CORROSION, EROSION AND DETERIORATION FROM THE RELEASE OF SEWER GASES SUCH AS METHANE AND HYDROGEN SULFIDE. 19. THE SEWER LIFT STATION DESIGN AND ASSOCIATED EQUIPMENT MUST MEET OR EXCEED THE MINIMUM REQUIREMENTS FOR HARNETT COUNTY SEWER LIFT STATIONS 2009 EDITION. EACH SANITARY SEWER LIFT STATION MUST BE CONSTRUCTED WITH AN ALL - WEATHER ACCESS ROAD THAT IS AT LEAST 20 FEET WIDE. THE LIFT STATION SITE MUST BE COVERED WITH WEED BLOCKING MATERIAL AND AT LEAST SIX (6 ") INCHES OF # 57 STONE (CRUSH AND RUN). 20. ONCE A SEWER LIFT STATION HAS BEEN INSTALLED, THE UTILITY CONTRACTOR IS RESPONSIBLE TO SCHEDULE A DRAW DOWN TEST WITH HCDPU ENGINEERING AND COLLECTIONS STAFF, THE PROFESSIONAL ENGINEER (PE), THE ELECTRICIAN, THE ORIGINAL EQUIPMENT MANUFACTURER'S (OEM) REPRESENTATIVES [FOR BOTH THE PUMPS AND THE GENERATOR]. THIS DRAW DOWN TEST MUST BE COMPLETED WITH POWER SUPPLIED FROM THE ELECTRICAL UTILITY COMPANY AND WITH POWER SUPPLIED BY THE EMERGENCY GENERATOR WITH SATISFACTORY RESULTS BEFORE FINAL INSPECTIONS ARE CONDUCTED BY THE HCDPU UTILITY CONSTRUCTION INSPECTOR. 21. ONCE THE UTILITY CONTRACTOR COMPLETES THE INSTALLATION OF A SEWER LIFT STATION, THE PROFESSIONAL ENGINEER (PE) MUST SUBMIT THE SEWER PERMIT CERTIFICATION AND AS -BUILT RECORD DRAWINGS TO THE NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES - DIVISION OF WATER QUALITY (NCDENR -DWQ) AND HCDPU FOR FINAL APPROVAL. THE UTILITY CONTRACTOR MUST SUPPLY HCDPU ENGINEERING STAFF WITH THREE ORIGINAL OPERATION & MAINTENANCE (0 &M) MANUALS ALONG WITH THE ASSOCIATED PUMP CURVES AND ELECTRICAL SCHEMATICS FOR THE ASSOCIATED SEWER LIFT STATION EQUIPMENT INCLUDING ALL WARRANTY INFORMATION AND DOCUMENTATION. 22. ONCE THE UTILITY CONTRACTOR COMPLETES THE INSTALLATION OF A SEWER LIFT STATION, THE DEVELOPER MUST PAY HCDPU THE ESTABLISHED SYSTEM CONTROL AND DATA ACQUISITION ( SCADA) FEES BEFORE THE SCADA SYSTEM WILL BE INSTALLED AT THE NEW SEWER LIFT STATION. THE SCADA SYSTEM MUST BE INSTALLED AND OPERATIONAL BEFORE THE UTILITIES MAY BE ACCEPTED BY HCDPU AND PLACED INTO OPERATION. 23. HCDPU REQUIRES THE UTILITY CONTRACTOR TO PROVIDE ALL NECESSARY EQUIPMENT AND DEVICES FOR THE TESTING AND INSPECTION OF THE SANITARY SEWER SYSTEM. THE EQUIPMENT AND DEVICES MAY INCLUDE BUT NOT LIMITED TO MIRRORS, MANDRELS, SEWER BALLS, PLUGS, AIR COMPRESSORS AND ASSOCIATED COMPRESSED AIR LINES. IF THE HCDPU UTILITY CONSTRUCTION INSPECTOR DEEMS THAT A CLOSED CIRCUIT VIDEO CAMERA INSPECTION OF THE NEWLY CONSTRUCTED SEWER SYSTEM IS NECESSARY, THEN ALL COSTS FOR THE CLOSED CIRCUIT CAMERA INSPECTION WILL BE THE RESPONSIBILITY OF THE UTILITY CONTRACTOR. ALL CLOSED CIRCUIT VIDEO CAMERA INSPECTIONS MUST BE RECORDED ON VHS TAPES THAT WILL RELEASED TO HCDPU FOR RECORD KEEPING, REVIEW AND APPROVAL OF THE SEWER SYSTEM. 24. ANY USE OF SEWER PLUGS TO TEMPORARILY BLOCK HARNETT COUNTY'S EXISTING SANITARY SEWER LINES MUST BE COORDINATED WITH THE HCDPU COLLECTIONS SUPERVISOR AT LEAST TWO (2) DAYS IN ADVANCE OF INSTALLING THE PLUGS. THE SEWER PLUGS MUST BE REMOVED AS SOON AS POSSIBLE ONCE THE NEW SANITARY SEWER LINES HAVE BEEN INSPECTED, PRESSURE TESTED, MANDREL TESTED, APPROVED BY THE NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES - DIVISION OF WATER QUALITY (NCDENR -DWQ) AND ACCEPTED BY HCDPU TO ALLOW THE SEWER TO FLOW AS DESIGNED IN HARNETT COUNTY'S EXISTING SANITARY SEWER LINES OR WHEN SO ORDERED BY THE HCDPU COLLECTIONS SUPERVISOR TO LIMIT INTERRUPTIONS TO THE NORMAL FLOW OF THE SANITARY SEWER COLLECTION SYSTEM(S). THE UTILITY CONTRACTOR MUST PROVIDE THE PUMPS HOSES AND NECESSARY CONNECTORS FOR A TEMPORARY PUMP AROUND SETUP IF REQUIRED BY THE HCDPU COLLECTIONS SUPERVISOR. MR. CURTIS SPEARS, HCDPU COLLECTIONS SUPERVISOR MAY BE CONTACTED BETWEEN 8:00 AM AND 5:00 PM MONDAY THROUGH FRIDAY AT (910) 893 -7575 EXTENSION 3243. 25. THE UTILITY CONTRACTOR WILL BE RESPONSIBLE FOR ANY AND ALL REPAIRS DUE TO LEAKAGE OR DAMAGE RESULTING FROM POOR WORKMANSHIP DURING THE ONE (1) YEAR WARRANTY PERIOD ONCE THE SEWER SYSTEM IMPROVEMENTS HAVE BEEN APPROVED BY THE NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES - DIVISION OF WATER QUALITY (NCDENR -DWQ) AND ACCEPTED BY HCDPU. THE UTILITY CONTRACTOR WILL BE RESPONSIBLE FOR ANY AND ALL REPAIRS DUE TO DAMAGES RESULTING FROM FAILURE TO LOCATE THE NEW SANITARY SEWER LINES AND ASSOCIATED APPURTENANCES FOR OTHER UTILITIES AND THEIR CONTRACTORS UNTIL THE SANITARY SEWER LINES HAVE BEEN APPROVED BY NCDENR AND ACCEPTED BY HCDPU. HCDPU WILL PROVIDE MAINTENANCE AND WARRANTY REPAIRS IF NECESSARY DUE TO LACK OF RESPONSE WITHIN 48 HOURS OF NOTIFICATION OF WARRANTY WORK. HCDPU WILL INVOICE THE DEVELOPER AND /OR UTILITY CONTRACTOR FOR MATERIALS AND LABOR IN SUCH CASES. 26. IN DEVELOPMENTS AND PROJECTS THAT REQUIRE UTILITY EASEMENTS TO BE ESTABLISHED FOR FUTURE HCDPU RIGHT -OF -WAY, THE REGISTERED LAND SURVEYOR (RLS) MUST PROVIDE THE HCDPU RIGHT -OF -WAY AGENT WITH AN OFFICIAL COPY OF THE RECORDED PLAT AND LEGAL DESCRIPTION OF THE SAID EASEMENT AS RECORDED WITH THE HARNETT COUNTY REGISTER OF DEEDS. THE RECORDED DOCUMENTS MUST BE PROVIDED TO THE HCDPU RIGHT -OF -WAY AGENT BEFORE THE UTILITY IMPROVEMENTS WITHIN THE SAID EASEMENT CAN BE PLACED INTO OPERATION. ANY AND ALL EASEMENTS THAT MUST BE OBTAINED FROM ADJOINING PROPERTY OWNERS MUST BE PROVIDED TO HCDPU BY THE DEVELOPER AT NO COST TO HARNETT COUNTY. THE FINAL INSPECTION OF ALL SANITARY SEWER SYSTEM IMPROVEMENTS CANNOT BE SCHEDULED WITH HCDPU UNTIL THE STREETS HAVE BEEN PAVED, THE RIGHTS -OF -WAY AND UTILITY EASEMENTS HAVE BEEN SEEDED AND STABILIZED WITH AN ADEQUATE STAND OF GRASS IN PLACE TO PREVENT EROSION ISSUES ON SITE. 27. THE ENGINEER OF RECORD IS RESPONSIBLE TO INSURE THAT CONSTRUCTION IS, AT ALL TIMES, IN COMPLIANCE WITH ACCEPTED SANITARY ENGINEERING PRACTICES AND APPROVED PLANS AND SPECIFICATIONS. NO FIELD CHANGES TO THE APPROVED PLANS ARE ALLOWED WITHOUT PRIOR WRITTEN APPROVAL BY HCDPU. A COPY OF EACH ENGINEER'S FIELD REPORT IS TO BE SUBMITTED TO HCDPU AS EACH SUCH INSPECTION IS MADE ON SYSTEM IMPROVEMENTS OR TESTING IS PERFORMED BY THE CONTRACTOR. WATER AND SEWER INFRASTRUCTURE MUST PASS ALL TESTS REQUIRED BY HCDPU SPECIFICATIONS AND THOSE OF ALL APPLICABLE REGULATORY AGENCIES. THESE TESTS INCLUDE, BUT ARE NOT LIMITED TO: AIR TEST, VACUUM TEST, MANDREL TEST, VISUAL TEST, PRESSURE TEST, BACTERIOLOGICAL TEST, ETC. A HCDPU INSPECTOR MUST BE PRESENT DURING TESTING AND ALL TEST RESULTS SHALL BE SUBMITTED TO HCDPU. ALL TESTS MUST BE SATISFIED BEFORE THE FINAL INSPECTION WILL BE SCHEDULED WITH THE HCDPU INSPECTOR. THE ENGINEER OF RECORD MUST REQUEST IN WRITING TO SCHEDULE THE FINAL INSPECTION ONCE ALL CONSTRUCTION IS COMPLETE. THE DEVELOPER'S ENGINEER OF RECORD AND THE HCDPU UTILITY CONSTRUCTION INSPECTOR SHALL PREPARE A WRITTEN PUNCH LIST OF ANY DEFECTS OR DEFICIENCIES NOTED DURING THE FINAL INSPECTION, SHOULD ANY EXIST. UPON COMPLETION OF THE PUNCH LIST, THE DEVELOPER'S ENGINEER OF RECORD WILL SCHEDULE ANOTHER INSPECTION. IN THE EVENT THE NUMBER OF INSPECTIONS PERFORMED BY THE HCDPU EXCEEDS TWO, ADDITIONAL FEES MAY BE ACCESSED TO THE DEVELOPER. 409 Chicago Drive - 5uife 112 Fayeffe Le, NorEh Carolina 28506 Phone: (910) 426 -6777 Fax: (910) 426 -5777 License Number: C -2554 =41 �Ii�IT� ���`. bo�UTIONb,INC A L NgNEE21NG A hu2VEYING A, GP_') A, CON')T2uCI0N LAYOUT A REVISIONS PROJECT NAME FOREST RIDGE ACCESS & UTILITY ROAD PROJECT NOTES CLIENT ODELL A. SMITH PROPERTIES, LLC. 400 Odell Road Spring Lake, North Carolina 28390 Phone: (910) 497 -2020 Fax: (910) 497 -0569 PROJECT INFORMATION DESIGNED BY: BEN DRAWN BY: BEN CHECKED BY: SCOTT PROJECT NUMBER: 512 DRAWING SCALE SEE SHEETS DATE RELEASED SEPTEMBER 27, 2012 SHEET NUMBER G -1.0 a 0 0 W s ® p? OVERLOOK RD. LINDEN yeti OAKSw w / SITE w • w w • WILSON DR, 6K\ / w �e�e + oZ n w w •?r w -a• w w w NORTI -1 w V w VICINITY MAP w 41 w NOT TO SCALE w ,t w w �• v w / w ,u .• •m w ., w w• w w v w w/ LEGEND: N/F — NOW OR FORMERLY R/W — RIGHT OF WAY w RCP — REINFORCED CONCRETE PIPE w DIP — DUCTILE IRON PIPE DI — DROP INLET / CI — CURB INLET w FES — FLARED END SECTION w + PROPERTY LINE ADJACENT PROPERTY LINE w w w TIE LINE RIGHT —OF —WAY w/ ss SANITARY SEWER LINE SD STORM DRAINAGE / WL WATER LINE OVERHEAD UILITY w TREE LINE BENCHMARK EM ELECTRICAL METER EB ELECTRICAL BOX PP M MAILBOX w` • UTILITY POLE w w a: la C GUY WIRE w� ❑T TELEPHONE PEDESTAL ® DROP INLET w �. �S SANITARY SEWER MANHOLE wv D4 WATER VALVE w w FIRE HYDRANT y, + 0 WATER METER w w a+ w w w a+ w• w w a+ w• w w` w ® CATCH BASIN w 4' 4 4' 4 w oco CLEANOUT RIP RAP w w ASPHALT w w w w w w 41 SOIL �. .� Ya Itt, •.�• w w ., •? w 2gS / a 319 0 3» EX CI #11603 \ w HOOD: 292.76 / \ 29� INV IN: 292.02 INV OUT: 287.55 (11588),_--' h 5 G 1 i r 1 1 I / PP4 EX CI #11591 HOOD: 297.33 INV OUT 291.69 (11588) 114, CO., ' GRATE: 294.56 SHELF: 290.42 3OTTOM: 285.51 Q 409 Chicago Drive - 5uife 112 Fayeff iLe, Nor-Eh Carolina 28506 `\ Fax: (91o91426 577/ 7 License Number: C-2554 \� 4P T boLUTION INC AENGNEE2ING A 5U 2VEYING A, GP_') A, CONhT2uCI0N LAYOUT A 319 316 REVISIONS \ , \ EASEMENTS, CEMETERIES, AND FLOODy AREA S. I, SEAN R. SEEVER, CERTIFY THAT THE CONTROL FOR THIS \ \ 7) LOCATIONS OF ALL UNDERGROUND UTILITIES LYING SURVEY WAS ESTABLISHED FROM AN ACTUAL GPS SURVEY WITHIN THIS MAPPED AREA MAY NOT BE SHOWN ON UNDER MY SUPERVISION. THIS GPS SURVEY WAS PERFORMED THIS PLAN. DEVELOPERS OR CONTRACTORS SHOULD TO C -211 FGCC SPECIFICATIONS RTK GPS WITH VRS FIELD \ I, SEAN R. SEEVER, CERTIFY THAT THIS CLASS "C" NOT ONLY MAKE SUBSURFACE INVESTIGATIONS BUT PROCEDURES WERE USED. THE COORDINATES WERE OBTAINED TOPOGRAPHIC MAP WAS DRAWN FROM AN ACTUAL SURVEY SHOULD ALSO ALLOW FOR CONTINGENCIES WHICH GRAPHIC SCALE THROUGH A GRID TO GROUND ADJUSTMENT USING THE \ PERFORMED UNDER MY DIRECT SUPERVISION AND THAT IT MIGHT ARISE BY REASON OF ENCOUNTERING COMBINED SCALE FACTOR SHOWN HEREON. THIS SURVEY WAS MEETS OR EXCEEDS THE NORTH CAROLINA ADMINISTRATIVE UNRECORDED LINES OR OF LINES BEING IN DIFFERENT 30 0 is 30 60 PERFORMED ON JULY 26, 2010 USING TWO TRIMBLE 5700 CODE 21.56.1605 AND 21.56.1606. WITNESS MY HAND AND LOCATIONS THAN INDICATED ON THIS SURVEY. RECEIVERS. \ SEAL THIS 17 DAY 0 SEPTEM6 A.D., 2012. 8) THIS PROPERTY DOES NOT LIE WITHIN A FLOOD ZONE ACCORDING TO MAP # 3710958400J OF THE FLOOD INSURANCE RATE, DATED OCTOBER 3, 2006. ( IN FEET ) JSS�il _____ ________ _________9) THE RIGHT —OF —WAYS AND PROPERTY LINES ARE SHOWN PROF ONAL LAND SURVEYOR — L -4571 PROFESSIONAL LAND SURVEYOR — L -4571 HEREON FROM HARNETT COUNTY GIS INFORMATION. 1 inch = 30 ft. 400r, or y '000" w w w �• w / CHECKED BY: JIMMY PROJECT NUMBER: / HORIZONTAL:1 " =30' I w / DATE SURVEYED MARCH 15, 2012 f 1420 SHEET NUMBER w w C— 1 • w w 41 41 w w w w w• � w w •� w w• u^ w w •� w/ 5 G 1 i r 1 1 I / PP4 EX CI #11591 HOOD: 297.33 INV OUT 291.69 (11588) 114, CO., ' GRATE: 294.56 SHELF: 290.42 3OTTOM: 285.51 Q 409 Chicago Drive - 5uife 112 Fayeff iLe, Nor-Eh Carolina 28506 `\ Fax: (91o91426 577/ 7 License Number: C-2554 \� 4P T boLUTION INC AENGNEE2ING A 5U 2VEYING A, GP_') A, CONhT2uCI0N LAYOUT A 319 316 REVISIONS \ , \ EASEMENTS, CEMETERIES, AND FLOODy AREA S. I, SEAN R. SEEVER, CERTIFY THAT THE CONTROL FOR THIS \ \ 7) LOCATIONS OF ALL UNDERGROUND UTILITIES LYING SURVEY WAS ESTABLISHED FROM AN ACTUAL GPS SURVEY WITHIN THIS MAPPED AREA MAY NOT BE SHOWN ON UNDER MY SUPERVISION. THIS GPS SURVEY WAS PERFORMED THIS PLAN. DEVELOPERS OR CONTRACTORS SHOULD TO C -211 FGCC SPECIFICATIONS RTK GPS WITH VRS FIELD \ I, SEAN R. SEEVER, CERTIFY THAT THIS CLASS "C" NOT ONLY MAKE SUBSURFACE INVESTIGATIONS BUT PROCEDURES WERE USED. THE COORDINATES WERE OBTAINED TOPOGRAPHIC MAP WAS DRAWN FROM AN ACTUAL SURVEY SHOULD ALSO ALLOW FOR CONTINGENCIES WHICH GRAPHIC SCALE THROUGH A GRID TO GROUND ADJUSTMENT USING THE \ PERFORMED UNDER MY DIRECT SUPERVISION AND THAT IT MIGHT ARISE BY REASON OF ENCOUNTERING COMBINED SCALE FACTOR SHOWN HEREON. THIS SURVEY WAS MEETS OR EXCEEDS THE NORTH CAROLINA ADMINISTRATIVE UNRECORDED LINES OR OF LINES BEING IN DIFFERENT 30 0 is 30 60 PERFORMED ON JULY 26, 2010 USING TWO TRIMBLE 5700 CODE 21.56.1605 AND 21.56.1606. WITNESS MY HAND AND LOCATIONS THAN INDICATED ON THIS SURVEY. RECEIVERS. \ SEAL THIS 17 DAY 0 SEPTEM6 A.D., 2012. 8) THIS PROPERTY DOES NOT LIE WITHIN A FLOOD ZONE ACCORDING TO MAP # 3710958400J OF THE FLOOD INSURANCE RATE, DATED OCTOBER 3, 2006. ( IN FEET ) JSS�il _____ ________ _________9) THE RIGHT —OF —WAYS AND PROPERTY LINES ARE SHOWN PROF ONAL LAND SURVEYOR — L -4571 PROFESSIONAL LAND SURVEYOR — L -4571 HEREON FROM HARNETT COUNTY GIS INFORMATION. 1 inch = 30 ft. 400r, or y '000" w w w �• w w CHECKED BY: JIMMY PROJECT NUMBER: 512 HORIZONTAL:1 " =30' I w DATE SURVEYED MARCH 15, 2012 f 1420 SHEET NUMBER w w C— 1 • w w 41 41 w w w w w• � w w •� w w• u^ w w •� w/ co N 4 ti q CLIENT ODELL A. SMITH PROPERTIES, I.I.C. 400 Odell Road Spring Lake, North Carolina 28390 Phone: (910) 497 -2020 Fax: (910) 497 -0569 PROJECT INFORMATION w w SURVEYED BY: RON DRAWN BY: SEAN CHECKED BY: JIMMY PROJECT NUMBER: 512 DRAWING SCALE w HORIZONTAL:1 " =30' I w DATE SURVEYED MARCH 15, 2012 f SHEET NUMBER w C— 1 • w w w " * "' g� ", s SR27Sy �2 / > w > ® p?� OVERLOOK RD. / w w - „, w LINDEN yeti w w q, w w OAKS SITE � �• w w w e WILSON DR• w � � w "w OK\ w w a / • w 0 e� "• oZ w�w , " \ 0 V w w , /411�� - \ Z _.,..' , ? 11 .. w "I. I'll" DESCRIPTION / K", ­­-, "",', 11, 'll I'll \ / _­ I `ll"11 r I", '\ )_ - I ll I ", 1, 11 - ,.�4,5 N�11 , M� 1�' 1, ll"l l, , NONE / % I 1, l I ��11 ­, 11 I" ,, ", HIGH QUALITY WATER (HQW) 7 DAYS NONE , � / � \ \`, ,,. ,, SLOPES STEEPER SITE NOTES 1., GRADING NOTES ` .,,-,,,EROSION CONTROL NOTES 1. ALL ELEVATIONS SHOWN ARE IN REFERENCE TO THE 1. THE CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR ALL 1. TEMPORARY EROSION CONTROL FACILITIES AND /OR PERMANENT FACILITIES INTENDED 14 DAYS ARE ALLOWED BENCHMARK AND MUST BE VERIFIED BY THE GENERAL LAND DISTURBING ACTIVITIES AND ENSURE COMPLIANCE WITH TO CONTROL EROSION OF AND EARTH DISTURBANCE OPERATION SHALL BE INSTALLED FLATTER CONTRACTOR. THE APPROVED EROSION AND SEDIMENTATION CONTROL PLAN. ".., BEFORE ANY EARTH DISTURBANCE OPERATIONS TAKE PLACE OR AT THE EARLIEST 2. EXISTING UNDERGROUND UTILITIES ARE SHOWN ONLY WHERE THE CONTRACTOR SHALL INSPECT AND MAINTAIN ALL EROSION POSSIBLE POINT DURING CONSTRUCTION. NONE EVIDENCE COULD BE FOUND TO VERIFY LOCATION. PRIOR TO CONTROL DEVICES AND CLEAR ANY DEBRIS LEAVING THE SITE 2. TEMPORARY & PERMANENT EROSION CONTROL MEASURES SHALL BE CONSTRUCTED WITH SLOPES FLATTER CONSTRUCTION OR EXCAVATION OF THE SITE, THE GENERAL ON NEIGHBORING ROADS. �M PER THE DETAILS HEREIN, OR SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CONTRACTOR SHALL VERIFY ALL UTILITY COMPANIES TO 2. EXISTING GROUND UPON WHICH FILL OR BASE IS TO BE r•� NORTH CAROLINA EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL. \ VERIFY THE LOCATION OF THEIR RESPECTIVE UTILITIES. ALL PLACED SHALL BE CLEARED OF WEEDS, DEBRIS, TOPSOIL, AND'-.11 3. REMOVE ALL SOILS AND SEDIMENTS TRACKED OR OTHERWISE DEPOSITED ONTO PUBLIC "\ DAMAGE INCURRED TO EXISTING UTILITIES DURING ALL OTHER DELETERIOUS MATERIALS; NO FILL SHALL BE `­ 11 , AND PRIVATE PAVEMENT AREAS. REMOVAL SHALL BE ON A DAILY BASIS WHEN \ CONSTRUCTION SHALL BE REPAIRED AT THE GENERAL PLACED UNTIL PREPARATION OF THE EXISTING GROUND HAS ',,,, TRACKING OCCURS. CONTRACTOR'S EXPENSE. BEEN COMPLETED ""' ��, 4. LOCATE SOIL STOCKPILES NO LESS THAN TWENTY -FIVE (25) FEET FROM ANY PUBLIC 11_11,11N 3. PRIOR TO CONSTRUCTION OR EXCAVATION OF THE SITE, THE 3. PROTECTIVE MEASURES SHALL BE TAKEN BY THE CONTRACTOR OR PRIVATE ROADWAY OR DRAINAGE CHANNEL. IF REMAINING FOR MORE THAN SEVEN, GENERAL CONTRACTOR SHALL VERIFY ALL UTILITY COMPANIES AND THE OWNER TO PROTECT ADJACENT PROPERTY, THE " \- DAYS, STABILIZE THE STOCKPILES BY VEGETATIVE COVER, TARPS, OR OTHER MEANS. TO VERIFY THE LOCATION OF THEIR RESPECTIVE UTILITIES. PUBLIC AND UTILITIES DURING GRADING OPERATIONS. THE „ CONTROL EROSION FROM ALL STOCKPILES BY PLACING SILT BARRIERS AROUND THE \ 'T \ w __ ALL DAMAGE INCURRED TO EXISTING UTILITIES DURING CONTRACTOR ASSUMES ALL LIABILITY FOR THE UNDERGROUND _", PILES TEMPORARY STOCKPILES LOCATED ON PAVED SURFACES MUST BE NO LESS \ o� w w w / _; CONSTRUCTION SHALL BE REPAIRED AT THE GENERAL UTILITY PIPES, CONDUITS, OR STRUCTURES, WHETHER SHOWN THAN FIVE FEET HE DRAINAGE/GUTTER UTTER LINE AND SHALL BE COVERED IF LEFT OR NOT ON THE PLAN F T I E/G w / ' CONTRACTOR'S EXPENSE. MORE THAN 24 HOURS. 1 I 4. ASPHALT AND BASE TYPE SHALL BE PER THE DETAILS. 4. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ACE -. � 5. ALL WASTE MATERIAL SHALL BE DISPOSED OF OFF -SITE IN THE LOCATION OF ALL UTILITIES OR STRUCTURES ABOVE AND '°'\ 5 ," _ ,� UNTIL THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED. INSPECT " " w „ � ACCORDANCE WITH STATE AND LOCAL LAWS AND BELOW GROUND, SHOWN OR NOT SHOWN ON THESE PLANS. ,.„ 1. ,: TEMPORARY EROSION AND SEDIMENT CONTROL DEVICES ON A DAILY BASIS AND ( / NORTH x � REGULATIONS. \O THEY WILL BE HELD RESPONSIBLE FOR ALL DAMAGE TO ANY „' REPLACE DETERIORATED, DAMAGED, OR ROTTED EROSION CONTROL DEVICES I " w w � / , 'l , w ", \ \ �S� Qg UTILITIES OR STRUCTURES CAUSED BY HIS OPERATION. IMMEDIATELY. \ . w \ �0� 5. ALL CUT AND FILL SLOPES SHOULD BE INVESTIGATED BOTH \\ , 6. TEMPORARILY OR PERMANENTLY STABILIZE ALL DENUDED AREAS WHICH HAVE BEEN VICINITY MAP w w w w DURING AND AFTER GRADING BY THE CONTRACTOR TO \ "- FINISH GRADED, AND ALL DENUDED AREAS IN WHICH GRADING OR SITE BUILDING C CONS RUCT ON OPERATIONS ARE NOT ACT VELY UNDERWAY AGAI ST ROSION DU T " ;, ", w w " ", w w * DETERMINE IF ANY SLOPE STABILITY PROBLEMS EXIST. IF IT IS 7 „ T I I N E E 0 , ," d. � :� ... �., ". , ,# �, w ,„ \ \ DETERMINED THAT THERE IS A SLOPE STABILITY PROBLEM THE RAIN, WIND AND RUNNING WATER WITHIN 14 DAYS. USE SEEDING AND MULCHING, � ll w- w w " w ENGINEER OF RECORD SHOULD BE NOTIFIED. NOT TO SCALE w " ," EROSION CONTROL MATTING, AND /OR SODDING AND STAKING IN GREEN SPACE AREAS w w � 6~ 6. STOCKPILE AREAS THAT WILL EXCEED 10' IN HEIGHT SHOULD w \ „, AND OTHERWISE APPROPRIATE MEASURES. USE EARLY APPLICATION OF GRAVEL BASE '� ,V u.... -w � BE GRADED WITH 3:1 SLOPES AND SURROUNDED BY SILT x....x. x.......w .m .............. �... � _ W....�• � .. w � w \ � TBM FENCE. ON AREAS TO BE PAVED. " '" w w 7. DO NOT REMOVE ANY EROSION AND SEDIMENT CONTROL DEVICES AFTER THE / `" w H.• * H.• „. �- $' � " 4D NAIL 10991 7. APPROVED COPIES OF THE GRADING AND EROSION CONTROL AL STABILIZATION AND PERMANENT 'l If, w 11 � 1 .__„- _ s (, � ti # PROTECTED AREA HAS UNDERGONE FIN x "\ a / # SHALL BE ON THE PERMITTED SITE WHILE WORK IS IN \ x.,- w w. w m.... lil w w � . '. � 6 `' . 1 99 528.80 PROGRESS. 8, L MEASURES SHALL TAKE PRECEDENCE OVER N 3 E 1, 9'''„ VEGETATION HAS BEEN ESTABLISHED °" ELEV: 317.28 8. ALL EXISTING DRAINAGE COURSES THROUGH THIS SITE SHALL, w w.. ALL OTH RL CONSTRUCTIONSACTIVIT ES. 0 M M ) r � NC GRID NAD 83 REMAIN IN A CONDITION SUCH THAT THEY CAN TRANSPORT w 0, , , 9. THE PERMITTEE SHALL BE HELD RESPONSIBLE FOR THE ACTIONS AND PERFORMANCE :„ „ w w w w w ,v > w ", GROUND STABILIZATION CHART w w v w w " w w " O)' (NSRS 2007) \ THE NATURAL DRAINAGE UNTIL FACILITIES TO HANDLE THE OF ANY OTHER PARTIES PERFORMING WORK ON THIS PROJECT. LEGEND: ,,- w w w " w ` \ NAVD 88 \ STORM WATER ARE CONSTRUCTED. THE CONTRACTOR SHALL 10. ALL EROSION AND SEDIMENT CONTROL PRACTICES WILL BE CHECKED FOR STABILITY N/F - NOW OR FORMERLY `" w " `" R/W - RIGHT OF WAY W w w , w ". - � / 'i, >" RCP - REINFORCED CONCRETE PIPE w * �, DIP - DUCTILE IRON PIPE > * w DI - DROP INLET � '# '° w CI - CURB INLET w w FES - FLARED END SECTION 4 w w �' PROPERTY LINE w ADJACENT PROPERTY LINE w " TIE LINE - RIGHT -OF -WAY w w �/ ss SANITARY SEWER LINE w SD STORM DRAINAGE " w ,� "/ wL WATER LINE // OVERHEAD UILITY • GUARD RAIL -LM-LM-LIMITS OF CONSTRUCTION - SF - SF - SILT FENCE LINE BENCHMARK ' w SITE AREA STABILIZATION STABILIZATION TIME DESCRIPTION TIME FRAME FRAME EXCEPTIONS PERIMETER DIKES, 512 SWALES, DITHCES 7 DAYS NONE AND SLOPES HIGH QUALITY WATER (HQW) 7 DAYS NONE ZONES IF SLOPES ARE 10' OR SLOPES STEEPER 7 DAYS LESS IN LENGTH AND ARE THAN 3:1 NOT STEEPER THAN 2:1, 14 DAYS ARE ALLOWED SLOPES 3:1 OR 7 -DAYS FOR SLOPES FLATTER 14 DAYS GREATER THAN 50 FEET IN LENGTH NONE ALL OTHER AREAS (EXCEPT FOR WITH SLOPES FLATTER 14 DAYS PERIMETERS AND THAN 4:1 HQW ZONES) � \O `••,. \ BE RESPONSIBLE FOR ANY DAMAGE DUE TO OBSTRUCTING AND OPERATION FOLLOWNG EVERY RUNOFF - PRODUCING RAINFALL BUT IN NO CASE ' ' O NATURAL DRAINAGE PATTERNS. ' w w ", ,W, / " „,,. \ �, \ LESS THAN ONCE EVERY WEEK. ANY NEEDED REPAIRS WILL BE MADE IMMEDIATELY TO, \ "" \ 9. ANY DEVIATION FROM THE APPROVED GRADING PLAN SHOULD `� " �`I , .. �\ " \ F RECORD PRIOR TO MAINTAIN ALL PRACTICES AS DESIGNED. \ BE REPORTED TO THE ENGINEER 0 °~ 11. PURSUANT TO G.S. 113A- 57(2), THE ANGLE FOR GRADED SLOPES AND FILLS SHALL " ^ \ `� „ \ IMPLEMENTATION OF THE CHANGE. BE NO GREATER THAN THE ANGLE THAT CAN BE RETAINED BY VEGETATIVE COVER ao I I 1 10. ALL SLOPES 3:1 OR STEEPER THAT EXTEND TEN FEET OR OR OTHER ADEQUATE EROSION CONTROL DEVICES OR STRUCTURES. IN ANY EVENT, 1. 11 / x• - -x.. ' "% � 40 ll" , 5' SIDEWALK S75 SLOPES LEFT EXPOSED WILL, WITHIN 14 CALENDAR DAYS OF COMPLETION OF ANY \ MORE SHALL BE LINED WITH NORTH AMERICAN GREEN w '` w` TEMPORARY EROSION CONTROL BLANKET OR EQUAL v�� `.> PHASE OF GRADING, BE PLANTED OR OTHERWISE PROVIDED WITH TEMPORARY OR l M 3oy',,, \ ♦� SUBSTITUTE. w w '; 8., X11 PERMANENT GROUND COVER, DEVICES OR STRUCTURES SUFFICIENT TO RESTRAIN ll /I , /.- - / V `•.„ \� O "'' \ EROSION. PURSUANT TO G.S. 113A-57(3), PROVISIONS FOR PERMANENT GROUND N ", w - I. poor .. m'I � O� \ COVER SUFFICIENT TO RETAIN EROSION MUST BE ACCOMPLISHED FOR ALL DISTURBED ,,. F~ (.x „/ � " ' AREAS WITHIN 14 WORKING DAYS OR 90 CALENDAR DAYS (WHICHEVER IS SHORTER) 1 � „. 4�C \ \ , FOLLOWING COMPLETION OF CONSTRUCTION DEVELOPMENT. w w \ 'I \ 12. CONTRACTOR IS RESPONSIBLE FOR INSTALLING ALL EROSION CONTROL MEASURES }__' \�bS,o" \ a" \; SHOWN AND ANY ADDITIONAL MEASURES REQUIRED TO CONTROL THE SEDIMENT / w w � C DURING THE COURSE OF CO CONSTRUCTION. " v \ 301. \ I E N 1;, w � \\ � 299 WETLAND IMPACT 13. ALL SEEDED AREAS WILL BE FERTILIZED, RESEEDED AS NECESSARY, AND MULCHED f' i\ ACCORDING TO THE DETAILS HEREIN w (`'� r �P AREA (3,779 SF) "" 'll c ,' ":, , 14. THE CONTACT PERSON FOR EROSION CONTROL ISSUES THAT ARISE ON SITE IS KEN \\ CI -3 °,, SMITH CONTACT 910 - 497 -2020 ...,.�. � w � , ,. 1 \ ! \ s>, V w 3.,. (A` w r ; , ; 'klal G w `% 1,. s ..... 00 "9O) m, 1 �� 7� C1iJ � \ P "\'`, ..,„, t x, , , \ w .. .. , ry \F, . w w w/ `\ oa V o� w , \ N `L� P , IF QF,� w O \ �`� Sgt I EM ELECRICAL METER w �� jcx \ `,, O,\/ �OG�, w w w''� .., <.ra �, RELOCATE EXISTING O '" ....w f,, ,,.„�...., 41 w .. ........�. _ a:, '., 11 Ee ELECRICAL BOX " " w\ �����4j, " w ;Y }r= w \ ,, \ SILT FENCE CONSTRUCTION S Q ENCE ff PPMB MAILBOX �- * $ w r , X , OG // / �� �$ ,'„ \ `v. \ "n, E U I .,. \, 1. OBTAIN ALL NECESSARY PERMITS AND APPRO A HOLD s# „ ' O VALS ND is • UTILITY POLE 00�' / " " \w r ,�,� / .x...�, w v 1 PRE CONSTRUCTION CONFERENCE. .1 f'" " C• GUY WIRE w w V / % ,„ J 2. INSTALL STONE CONSTRUCTION ENTRANCE WHERE SPECIFIED. r� ❑T TELEPHONE PEDESTAL w w Z.- w/ 001 BOG / \ w o° ' 3n�i \, '' 3. ROUGH GRADE THE SITE AND APPLY TEMPORARY SEEDING TO ff w EMI INLET ,� ,� ,� �iW / ;3 }: � ��_ �c�31^� `.�� '� � �, '" � ,•.4 � ,� f ­11.11 _. AREAS REMAIN GRASSED fx G / , � w \ # 4. INSTALLRTEMPORARY SILT FENCE AS SHOWN. WW ff \S SANITARY SEWER MANHOLE w w ,..x ,3,3 ,� \ U 5. INSTALL UTILITIES ' " 11 w w w w w w w 11 ..wp' / 2, ,� w CT .I 6. PERFORM FINE GRADING. 5:,`" \" D4 WATER VALVE f .x. , / � �� w a ' \ 1 w w w w w w.. / "; �� ��' 1 a� 00 \ �, 7. INSTALL AND PREPARE BASE COURSE. x 11 ", \. , .. ,g ," ,w .{w rr +� ,,' .., , der"' Wry ✓; w 'FIRE HYDRANT w www w w yY° ." w ". ," w ". ,� w ". ,� w ". O / OWNER TO OBTAIN h n s \ 8. PAVE ROADWAY. d\ w * w , ? 7r \.... „v YIW II. <' -;,S ;1 �. d . ,, ddr'' ;d, w /// PERMISSION FROM " tS \_ 9. FERTILIZE, SEED AND MULCH ALL REMAINING DISTURBED � W w ❑❑ WATER METER " w ,, w w ,, w w w � ,, w w w w w �, " " w " ", w .,,.,,. w ,- !' OG �� \ ; w w LOT 1 OWNER PRIOR w \ \ \ N 4 ', w ® CATCH BASIN „. w w w w w w w 70^ / # l `� A' ' AREAS. W TO GRADING OUTSIDER W O G ,,,y- ,x 10. UPON SITE STABILIZATION, SEEK NCDENR APPROVAL TO , * w CO w ... 'i w ... 'i w . 'i �, ,. w w w w� / / 2 q ,r,, CLEANOUT w w .a w l rx ".00, w w w w w ,� 3 / G "` / I /J �j 5' x. \ If, I w 0INLET PROTECTION w I' r O� b0 x \ w . •v ,y 1 F \ '_" 11. ALLIOEROSI N CON ROL M ASURESESHALL BE MAINTAINED AS 10" w ��� J- r,: o ' \.w w „y �P t, \ ' }• : ', ?4"� OUTLINED IN THE DETAILS WITHIN THE PLANS AND ACCORDING , rvr,rv��rv�'m RIP RAP 1, 11 "` A AREA .,�" '` TEMPORARY SILT �\ :r "`J I/ " w a....1 / G/ 29in �' J ....... / TOTE R ER ION N �,,.'";; " H L I NCDEN OS CONTROL MA UA w.d •\ O FENCE (TYP) .�r (n O t Wd dd " w ,, ,, 70 \, - � sk ? t I <�, \\ REMOVE EXISTING '/ ,W ;" / w w ,.-/ ..,. / / �' \`�� �'• (.. 3 1STORM BOX AND PIPE �. " },,, " dd d / w w w / V w G: " „. Csa t h a . 1 , w , \ t .�_.,�' �^ r f� \ .......1' L`',,.,�•' 0 ,a`" w C.I k, ='�.�I; s��'�.�'... �t;' � / / r,r'' ff'�` fr. �;rW -,>00� o w w w w \ \.,' C�1P,11 \: F. w iN 1 292 0 "I s{ I f �:W, / a 11 3� / ..•� CONVERT EXISTING CI W ". % I "• , w " ", , ,....,� /_ OG \ , rrc �,.„ ':. t =,�;I u".1•, .t'.v.: a 5 (11 � 8t�'..i �' _ ,,r''"� .� •�`""� '�'� " r r''"'� : I :" s .� � �, \ : TO JB. RAISE TO ELEV � 4" � ;NEW` INV IN 288.00 71 €� 9 \ , \ ; `�' w n n\ 295.00' /� a ` } rr / z \ ? i, \ Off, 2 9 % } 4 ( CI 1 s : ff7 w w w ^, r' 'k- BOG \ � - '� '; 2 6 t? H t t . I : , . \ ff -h % w � )U1,tit \ f" T3 F 1 , , 1 ;, ,. r` " f / '4, : ...., '` 4? ' ✓ .adds '' ,�:v w , i ,� BOG \ �-� F PLO _ `i, F ®oQ !. -xf ffWd d f O a w O \,\ k. � �r R 5.87` LF ®17.03% f x } dd .� \G �\G �`L G oo 70 '',5 / t I .,�'.... / / ,. \ �� QG 0I -. ?�" �o��•\� CI -2 j_ f f f ffff .k G 'C w. , / O S LIMITS OF CONSTRUCTION O , % OG \ �� F' 0.65 ACRES '\ C\P,n I . x W` „ mr,,, 11 t ........_ F\ ;, O '; V G °SCI -1 I , , // , / , w .,.,... \ \ v \.OG f � ,• ,, OA �O ( 29 t � * , 'i, ;, ,r y5 5 \ TEMPORARY INLET"'•,. 1\ " 'o" r iffi , : // I 11 11 1 `; a / r Y . \ \ PROTECTION (TYP) " I l 2 XI U & GUTTER I „, '\ / ''. OG \ \emu' " a REMOVE &REPLACE E STING C CURB GUT R I '' „ / 1 I t %/ I /70 / \ \ \ f f` (}I ° (fits / I rv-� r' G _ �y�, \ ,. v r G S (- I `' 6 ... ', „. f 1;.. / I / '; .r ` \ \ TEMPORARY \ W "3 ...i { fff / I \ '', '', / G \ CONSTRUCTION s 4 y �F, ". �, � � ., O \ } r / , 70 ', \� \ \ ENTRANCE OG � �� g�� f, / .... `.._/ .� �� N p REMOVE & REPLACE `� 0\ \G /'ii i \ � ',,,, OpA \,O� , \\ (` _/ O Py0 \ EXISTING CURB &GUTTER ""11 0 � ADO Q\ I ry .: i 1 ,., ",� IF gOy 00 \ A AN ;{ N.::I; I ,O' ���5 INV O 9 ,66 (11561.3 /•., I / \, P 0 G \ x #115,24. P F i „\ 001 \,O? \ � PP�G� qG �p \ 1GRtt 1. { •$: � C = 1 i � , ���� ...„ , /„ \, / \ ��\F O� F S \ / INN Ih� 2,82' (, fz!m) ,jai..,° �£ "/ l"K ��\ f \ QG% \ I'll >� � INN rOU 2.82 (`1 3 „ / t s.. G \ / '1 \ z a , .. ...,. i, .....rr a 0110 <_\(,(,,��-�,V�`11 r \ \ " / a EX C1 / 3 3 , P �' ti 11 / \ \ \ l", / A., NV IN, 286,1 � "1561 x ,9�. \a ,��� \ 0� i rv. ry I ,C \ \ -. \ WN ... i ... S \`� ll " ,%\,,�,, � I Ill - �r\ I ... - I., ..... - . ti , . I I'll- I �­­ l \ 1/1-1- .--.. - _­ ­_­ - 1 \ f .. ' „ \, \ My n '\ .. \ \ \ \ -, l', 11 �, ­� \ , ". " , ,\ \�- w \ � "' \, , _ Il / ta ,\ \\ w \ ' w ,"\ ,j, � \ \ \ } } \ f, „ x... \r • " ' \ \ ° \ \ c \ £ \ .....- „ I ,# w w W w , „ y. \ " t gg* \ \ """' GRAPHIC SCALE w w w \\" \', \ CO w 11, l \ w w \ \ ✓dd / 30 0 15 30 60 120 w w w w `�' , ', \'.,", w Know what's b @IOW. } f w ;ryrv. � z " \\ 2 ....... \ ................. \ 3 w w \ \ ,, C111 before you dig \ `' ' • \ f \ \ ( IN FEET )\ 6F \ ., �,r : { '+ I I, v w I v v " w w � w \ \ 1 inch = 30 ft. w w w \ ~, "6,6 - ZeJ4 2 , "I "` - � _ _ _ _ # # # �\` � \ Or 11 } ; / 4 ' ," ,r w ," ,w w ," ,w : '�', ik.y \ \ lea „.. w THE CONTRACTOR MUST CONTACT NORTH CAROLINA ONE CALL CENTER AT 1- 800 - 632 -4949 A MINIMUM OF 48 HOURS PRIOR TO DIGGING IN ORDER TO HAVEnTHE EXISTING UTILITIES \ LOCATED 1� 409 Chicago Drive - 5uife 112 Fayeff iLe, NorEh Carolina 28506 � Fax: (91091426 577/ 7 \ \\\ License Number: C -2554 \ � n i T \ \� bOL_UTIONb,INC AENgNEE2ING A hu2VEYING A, GP_') A, CON')T2uCI0N LAYOUT A REVISIONS PROJECT NAME FOREST RIDGE ACCESS & UTILITY ROAD SITE AND GRADING PLAN CLIENT ODELL A. SMITH PROPERTIES, LLC. 400 Odell Road Spring Lake, North Carolina 28390 Phone: (910) 497 -2020 Fax: (910) 497 -0569 PROJECT INFORMATION DESIGNED BY: BEN DRAWN BY: BEN CHECKED BY: SCOTT PROJECT NUMBER: 512 DRAWING SCALE HORIZONTAL:1 " =30' DATE RELEASED SEPTEMBER 27, 2012 SHEET NUMBER C -2.0 O J 0 LINDEN OAKS SITE Ic OK\ e e 06 VICINITY MAP NOT TO SCALE LEGEND: N/F — NOW OR FORMERLY R/W — RIGHT OF WAY RCP — REINFORCED CONCRETE PIPE DIP — DUCTILE IRON PIPE DI — DROP INLET CI — CURB INLET FES — FLARED END SECTION —PROPERTY LINE ADJACENT PROPERTY LINE —TIE LINE RIGHT—OF—WAY _ss SANITARY SEWER LINE SD STORM DRAINAGE WL WATER LINE // OVERHEAD UILITY - - - - - - -- GUARD RAIL TREE LINE BENCHMARK [Eml ELECTRICAL METER [EBI ELECTRICAL BOX [MB MAILBOX PP • UTILITY POLE C- GUY WIRE M TELEPHONE PEDESTAL EMI DROP INLET 2 SANITARY SEWER MANHOLE >< WATER VALVE Y, FIRE HYDRANT U WATER METER Iff CATCH BASIN oco CLEANOUT * PROPOSED SANITARY SEWER MANHOLE • PROPOSED BLOW OFF � PROPOSED PLUG �,% RIP RAP z C. N\ N\ TBM 4D NAIL #10991 N: 546,457.223 E: 1,991,528.809 MH-4 ELEV: 317.28 STA 4+05.53 103.28 L NC GRID NAD 83 RIM 300.87 (NSRS 2007) INV OUT 290.60 (MH-3) NAVID 88 MH-3 STA 2+63.49 9.40 R N\ RIM 301.18 N V IN 290.07 (MH-4) INV OUT 290.07 (MH-2) MH-2 STA 2+28.45 5.00 R RIM 301.17 NV IN 289.80 (MH-3) 0, INV OUT 289.70 (MH-1) '000� 36.39 LF @ 0.74% 8" SDR 35 PVC Vs 4" SDR 21 FIRE LINE FOR FUTURE DEVELOPMENT EX C �\v'O'N): 292.76 11`42 IN: 292,02 5 5 , 5 ,,�NEW INV IN '288.00 TAP EXISTING 6" WATER MAIN STA 0+42.2 GRA11 A, XC 1 1,585,.* BEN #1 SCOTT .0 -( INV N':' 2' 82 "588) (`1563\ INV OUT.-,,�40 2.82 \6- • 9-Ar. MH-1 STA 1+30.31 0.00 \RIM 290.19 01 NV IN 281.10 (MH-2) X INV OUT 281.00 (SSMH #8142) @ 4) CONTRACTOR SHALL DETERMINE INVERT LOCATION PRIOR N TO CONSTRUCTION c� < ""000, X430"OoX �Eo .13 SSW -1 #8142 (CORE BORED) Vs 4" SDR 21 FIRE LINE FOR FUTURE DEVELOPMENT EX C �\v'O'N): 292.76 11`42 IN: 292,02 5 5 , 5 ,,�NEW INV IN '288.00 TAP EXISTING 6" WATER MAIN STA 0+42.2 1 "., N1, 0 I Og G � ,,•� f �� �r� oo Or- I Az 0 10 90 CP 7 ",0000e RVA -1 a I �* 409 Chicago Drive ­5uife 112 fayeffe Le, Nor•Eh Carolina 28506 Phone: (gio) 426-6777 Fax: (gio) 426-5777 License Number: C-2554 4P T L bOLUTIONb INC A L NqNE L P_NG A A, GP_') A, C,1N_')TP_L1CF10N LAY61LIT A REVISIONS PROJECT NAME FOREST RIDGE ACCESS & UTILITY ROAD UTILITY PLAN CLIENT ODELL A. SMITH PROPERTIES, I.I.C. 400 Odell Road Spring Lake, North Carolina 28390 Phone: (910) 497-2020 Fax: (910) 497-0569 PROJECT INFORMATION DESIGNED BY: GRA11 A, XC 1 1,585,.* BEN #1 SCOTT .0 -( INV N':' 2' 82 "588) (`1563\ INV OUT.-,,�40 2.82 1 "., N1, 0 I Og G � ,,•� f �� �r� oo Or- I Az 0 10 90 CP 7 ",0000e RVA -1 a I �* 409 Chicago Drive ­5uife 112 fayeffe Le, Nor•Eh Carolina 28506 Phone: (gio) 426-6777 Fax: (gio) 426-5777 License Number: C-2554 4P T L bOLUTIONb INC A L NqNE L P_NG A A, GP_') A, C,1N_')TP_L1CF10N LAY61LIT A REVISIONS PROJECT NAME FOREST RIDGE ACCESS & UTILITY ROAD UTILITY PLAN CLIENT ODELL A. SMITH PROPERTIES, I.I.C. 400 Odell Road Spring Lake, North Carolina 28390 Phone: (910) 497-2020 Fax: (910) 497-0569 PROJECT INFORMATION DESIGNED BY: BEN DRAWN BY: BEN CHECKED BY: SCOTT I PROJECT NUMBER: 1 512 DRAWING SCALE HORIZONTAL: 1 "=30' DATE RELEASED SEPTEMBER 27, 2012 SHEET NUMBER C -3.0 Q 0 N O N V N W w W 0 a O v 310 305 300 295 290 285 0 tr k �� l{ cp , � •A rrl Z \�/ . ...... _ r ay' X" ro Y� ^rnN iY C'j LO 7 N N I I � y�o�wy'ay`'y> Q; - QixCv A00� �Ox4' L�� V V OV O� .4 /rya /ry1 ro0 X ryal C'> A/ a 00 ACCESS ROAD 50' R/W (PRIVATE STREET &UTILITY ACCESS) ROADWAY PROFILE -0 +50 TO 5 +00 h IUM h'UIIV 1 LLLV = )U1.4U HIGH POINT STA = 2 +53.53 PVI STA = 1 +70.08 PVI ELEV = 301.85 A.D. _ –6.56% K = 30.00 197' VC LOW POINT ELEV = 293.65 LOW POINT STA = 0 +20.18 BEN DRAWN BY: BEN CHECKED BY: N 0 Un o_ c6coN � I I = _N O = of : = I U) 0 O^ 0 00 r- m(N ° +o� coo CD J M I N 0 o n o PVI STA = 0 +45.13 n' - N N r) z o —� I,N PVI ELEV = 294.28 Q� n No0 =��» n +0Nj Z r� rr)z o OdH +oz) A.D. = 3.56% �v~i �cn–z K = 14.00 z �c~i)�zz =<�o 50' VC z O M N EE / / \ O O I PROPOSED GROUND 1 _ 0.50% .. c°o 77 J N _ Ui �G 0 o j `j .xw. 36" MIN COVER (WATER) 'n O n m 1� 00 N LO Cn0 n Loy _— N I �NZ + NNE �� /...::: FUTURE II cn �_ /... 36" RCP om II N Q N— — 6" SDR 21 WATER MAIN I > > > RCP. �N�_zzz CONTRACTOR TO CONFIRM DEPTH OF EXISTING WATER —MAIN PRIOR TO CONSTRUCTION 30.00 LF 1.67% 18" RCP TIE TO EXISTING 6" WATER MAIN I'P LO N + > n v H to N 8" SDR 26 PVC 71.26 LF 00 -74% 36.39 LF ® 0.74% M L ' M N N N N N N N N N N N 0 +00 1 +00 2 +00 3 +00 Q . - . N O O O 0 O 0 N � 4 +00 L M n O II n Q u c~i> > G� l� h 409 Chicago Drive - 5uife 112 Fayeff iLe, NorEh Carolina 28506 Fax: (91091426 577/ 7 License Number: C -2554 \� 4P T boLUTIONb,INC A ENGNEE2ING A 5U 2VEYING A, GP_') A, CON')T2L1CI0N LAYOUT A REVISIONS 310 PROJECT NAME I FOREST RIDGE ACCESS & ,cs UTILITY ROAD 300 ACCESS ROAD PROFILE 295 290 285 111111610 5 +00 GRAPHIC SCALE 30 0 15 30 60 ( IN FEET ) 1 inch = 30 ft. CLIENT ODELL A. SMITH PROPERTIES, LLC. 400 Odell Road Spring Lake, North Carolina 28390 Phone: (910) 497 -2020 Fax: (910) 497 -0569 PROJECT INFORMATION DESIGNED BY: BEN DRAWN BY: BEN CHECKED BY: SCOTT PROJECT NUMBER: 512 DRAWING SCALE HORIZONTAL:1 " =30' VERTICAL:1 " =3' DATE RELEASED 120 SEPTEMBER 27, 2012 SHEET NUMBER C-400 0 0 0 w 0 CONY /NCR TOR TO CONS ON pF 1off 0� F .0+00 130.31 LF @ 6.25% 8" SDR 35 PVC 1+00 s - SS SS e -------- s 40 — -A, 6' STA: 0+67.99 E 4' (.,HAIN[ INK FENC' TOP 286.69 > 0 INV: 281.38 A 0'(00' 0 &0, ID) 300 295 290 285 WN] 275 272 N/F x. ODELL A SMITH PROPERTIES, LLC D13 2285, PG 427 ?0 .... . . .... 0 J 4l- S, ?9,3 p 0 //� 0 .3 00.4 '7 9 " 000 00 0 00 r* 2+00 299.78 LF @ 2.87% 8" SDR 35 PVC SS SS SS Iss — STA: 1+92.87 TOP: 291.64 INV: 285.29 SEWER EXTENSION 0"1 A 1k I I -r' A r-% X ff r% r- 11 A I r- r% r% . r- r% _r, A-% A . r- 0% 0 ft' 0," o 0, 0 .70 19 '5. 0 60 19 1 '-'a 7 46 J' 880 J 11�07 O(/T2900 9 9 2900 >r*. S r 's' RJ 14,07 .7 06'1--Ild9> '00 <9,0 r 0 �My 3J q9 C' + 08 -.j C4 �' �' �/�' so. (D '0 ' A', " -)/ 01P 60 0+00 1+00 2+00 3+00 4+00 300 295 290 285 We] 275 272 GRAPHIC SCALE 30 0 15 30 60 ( IN FEET ) 1 inch = 30 ft. 120 409 Chicago Drive —5uife 112 fayeff il_Le, Norih Carolina 28506 Phone: (gio) 426-6777 Fax: (gio) 426-5777 License Number: C-2554 4P T L bOLUTIONb, INC A ENqNELP-ING A A, GP_') A, C,1N_')T2L1CF10N LAYILIT A REVISIONS PROJECT NAME FOREST RIDGE ACCESS & UTILITY ROAD SEWER PROFILE CLIENT ODELL A. SMITH PROPERTIES, LLC. 400 Odell Road Spring Lake, North Carolina 28390 Phone: (910) 497-2020 Fax: (910) 497-0569 PROJECT INFORMATION DESIGNED BY: BEN DRAWN BY: BEN CHECKED BY: SCOTT I PROJECT NUMBER: 1 512 DRAWING SCALE HORIZONTAL: 1 "=30' VERTICAL: 1 "=3' DATE RELEASED SEPTEMBER 27, 2012 SHEET NUMBER C-401 0 0 0 N 0 N W J Q W 0 0 U 409 Chicago Drive - 5uife 112 Fayeff iLe, NorEh Carolina 28506 Phone: (910) 426 -6777 Fax: (910) 426 -5777 License Number: C -2554 4P 51TL bOLUTIONb, INC A ENGINEL P-NG A 2VEYING A, GP_') A, CON')TP_L1Ci1ON LAYOLIT A REVISIONS PROJECT NAME FOREST RIDGE ACCESS & UTILITY ROAD SITE AND EROSION CONTROL DETAILS CLIENT ODELL A. SMITH PROPERTIES, LLC. 400 Odell Road Spring Lake, North Carolina 28390 Phone: (910) 497 -2020 Fax: (910) 497 -0569 PROJECT INFORMATION DESIGNED BY: 6„ 18„ DRAWN BY: BEN CHECKED BY: SCOTT PROJECT NUMBER: 512 FINISH GRADE SF9.5A 30' BC -BC 3 R �e 5 15' 15' 5' 2 , N..... .. :: :: :: :: :: :: :: e 2' oP 13 2 �� 13 S� :.. 3bOO' PSI CONCRETE . 8% 2 S F9 ♦ -8% : o 5A 2% , : III .. ' - . ......... 6 CABC GROUP E ° 9 STBC OR l.al ......., ...... e pe (mq 24° _ rE 6" COMPACTED 6„ ABC 1 Shop k �. ....... w z - z COMPACTED w DUMMY GROOVE JOINTS EVERY 10' SUBGRADE � EXPANSION JOINTS EVERY 50' CARRY BASE COURSE 6" BEYOND (90' IF MACHINE PLACED) AT ATIIONSAWTHOOTRSE CURB AND GUTTER NTS NTS NTS 1 24" STANDARD CURB & GUTTER 2 PAVEMENT SECTION 3 ROADWAY TYPICAL SECTION STANDARD METAL POSTS 2' -0" IN GROUND 19 GAUGE HARDWARE CLOTH (1/4 MESH OPENINGS) 1. UNLESS OTHERWISE INDICATED, ALL VEGETATIVE AND 7. ALL DISTURBED AREAS ARE TO DRAIN TO APPROVED SEDIMENT m STRUCTURAL EROSION AND SEDIMENT CONTROL MEASURES SHALL CONTROL MEASURES AT ALL TIMES DURING LAND DISTURBING - ...... "" CONSTRUCTION SPECIFICATIONS BE CONSTRUCTED AND MAINTAINED IN ACCORDANCE WITH THE ACTIVITIES AND DURING SITE DEVELOPMENT UNTIL FINAL m MINIMUM STANDARDS AND SPECIFICATIONS OF THE NORTH STABILIZATION IS ACHIEVED. d 1. UNIFORMLY GRADE A SHALLOW DEPRESSION CAROLINA EROSION AND SEDIMENT CONTROL HANDBOOK. APPROACHING THE INLET. 8. ALL AREAS DISTURBED BY CONSTRUCTION UNLESS OTHERWISE ' � - .................................. --- ••.m- ______ 2. DRIVE 5 -FOOT STEEL POSTS 2 FEET INTO THE GROUND SEEDING SPECIFICATIONS 2. THE CONTRACTOR SHALL NOTIFY PLAN APPROVING AUTHORITY IMPROVED SHALL BE SODDED OR SEEDED AS INDICATED AND ONE WEEK PRIOR TO THE PRECONSTRUCTION CONFERENCE, ONE STABILIZED. SURROUNDING THE INLET. SPACES POSTS EVENLY AROUND TEMPORARY SEEDING /MULCHING SPECIFICATIONS (FOR LATE WINTER AND EARLY SPRING) SEEDING MIXTURE: SEEDING MIXTURES: WEEK PRIOR TO THE COMMENCEMENT OF LAND DISTURBING ACTIVITY, AND ONE WEEK PRIOR TO FINAL INSPECTION. 9. DURING DEWATERING OPERATIONS, WATER SHALL BE PUMPED INTO AN APPROVED FILTERING DEVICE PRIOR TO DISCHARGE TO „I+ THE PERIMETER OF THE INLET, A MAXIMUM OF 4 FEET - APART, ........ ............................... {1 3. "t C -"" (, ih� a. F.w� � 3. SURROUND THE POSTS WITH WIRE MESH HARDWARE SPECIES RATE (LB. /ACRE) SPECIES RATE (LBS. /ACRE) 3. IF POSSIBLE ALL EROSION AND SEDIMENT CONTROL MEASURES RECEIVING OUTLET. ARE TO BE PLACED PRIOR TO CLEARING AND /OR LAND DISTURBANCE. p ti CLOTH. SECURE THE WIRE MESH TO THE STEEL POSTS AT THE TOP, MIDDLE AND BOTTOM. PLACING A 2 FOOT FLAP r °""" "" OF THE WIRE MESH UNDER THE GRAVEL FOR ANCHORING RYE (GRAIN) 120 TALL FESCUE 80 10. THE CONTRACTOR SHALL INSPECT ALL EROSION CONTROL IS RECOMMENDED. ANNUAL KOBE LESPEDEZA 50 PENSACOLA BAHIAGRASS 50 4. A COPY OF THE APPROVED EROSION AND SEDIMENT CONTROL MEASURES WEEKLY AND AFTER EACH RUNOFF - PRODUCING EVENT. s xY 4 OMIT ANNUAL LESPEDEZA WHEN DURATION OF TEMPORARY COVER IS NOT EXTEND BEYOND JUNE. SERICEA LESPEDEZA 30 PLAN AND PERMIT SHALL BE MAINTAINED ON THE SITE AT ALL TIMES. ANY NECESSARY REPAIRS OR CLEANUP TO MAINTAIN THE "" ...-- "° " " 4. PLACE CLEAN GRAVEL (NCDOT #5 OR #57 STONE) ON KOBE LESPEDEZA 10 EFFECTIVENESS OF THE EROSION CONTROL DEVICES SHALL BE ............... ... A 2:1 SLOPE WITH A HEIGHT OF 16 INCHES AROUND THE SEEDING DATES: 5. PRIOR TO COMMENCING LAND DISTURBING ACTIVITIES IN AREAS MADE IMMEDIATELY. 2:1 SLOPE GRAVEL FILTER 57 WASHED STONE PLACED TO A HEIGHT OF 16" WIRE AND SMOTH TO AN EVEN GRADE. JANUARY 1 -MAY 1 SEEDING NOTES: OTHER THAN INDICATED ON THESE PLANS (INCLUDING, BUT NOT LIMITED TO OFF -SITE BORROW OR WASTE AREAS, STAGING OR 11. ALL TEMPORARY EROSION CONTROL MEASURES SHALL BE MINIMUM ABOVE TOP OF BOX 5. ONCE THE CONTRIBUTING DRAINAGE AREA HAS BEEN 1. FROM SEPT. 1 TO MAR. 1 USE UNSCARIFIED SERICEA SEED. STORAGE AREAS), THE CONTRACTOR SHALL PREPARE AND SUBMIT REMOVED BY CONTRACTOR ONCE STABILIZATION OR A SUFFICIENT STABILIZED, REMOVE ACCUMULATED SEDIMENT AND SOIL AMENDMENTS: 2. ON POORLY DRAINED SITES OMIT SERICEA AND INCREASE KOBE TO 30 LBJACRE. A SUPPLEMENTARY EROSION CONTROL PLAN TO THE OWNER FOR GROUND COVER HAS BEEN ESTABLISHED OR AS DIRECTED BY THE ESTABUSH FINAL GRADING ELEVATIONS. FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB. /ACRE GROUND AGRICULTURAL LIMESTONE AND 750 3. WHERE A NEAT APPEARANCE IS DESIRED, OMIT SERICEA AND INCREASE KOBE TO 40 LBJACRE. REVIEW AND TO NCDENR REGIONAL OFFICE FOR APPROVAL. ENGINEER. NCDENR'S FINAL APPROVAL IS REQUIRED. 6. COMPACT THE AREA PROPERLY AND STABILIZE IT WITH LB. /ACRE 10 -10 -10 FERTILIZER. CONTRACTOR SHALL PAY ALL FEES REQUIRED AND SHALL INSTALL GROUNDOOVER. NURSE PLANTS: NECESSARY MEASURES AT NO SEPARATE PAYMENT. THE 12. TEMPORARY GRAVEL CONSTRUCTION ENTRANCE SHALL BE MULCH: BETWEEN APRIL 15 AND AUG. 15, ADD 10 LB. /ACRE OF GERMAN MILLET OR 15 LB. /ACRE SUDANGRASS. PRIOR TO MAY 1 CONTRACTOR SHALL PROVIDE THE OWNER AND THE ENGINEER A REQUIRED AT ALL CONSTRUCTION STAGING AREA ENTRANCES AND APPLY 4,000 LB. /ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. OR AFTER AUG. 15, ADD 25 LBJACRE RYE (GRAIN). COPY OF THE AMENDED PERMIT. ALL CONSTRUCTION ACCESS LOCATIONS INTO NON -PAVED AREA. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. 6. THE CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF ANY 13. WHEN CROSSING CREEK OR DRAINAGE -WAY, THE CONTRACTOR SEEDING DATES: ADDITIONAL EROSION CONTROL MEASURES NECESSARY TO PREVENT SHALL RIP -RAP WITH FABRIC DISTURBED BANKS AND CHANNEL AND MAINTENANCE: BEST POSSIBLE EROSION AND SEDIMENTATION AS DETERMINED BY EITHER NCDENR RESTORE SLOPES TO ORIGINAL CONTOURS, BUT NOT STEEPER THAN REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE AND MULCH IMMEDIATELY FOLLOWING EARLY SPRING: FEB. 15 - MAR. 20 FEB. 15 - APR. 30 OR THE ENGINEER. 2:1 MAXIMUM. DISTURBED CREEK AREA SHALL BE STABILIZED EROSION OR OTHER DAMAGE. FALL: SEPT. 1 - SEPT. 30 SEPT. 1 - OCT. 31 IMMEDIATELY. MAINTENANCE TEMPORARY SEEDING /MULCHING SPECIFICATIONS (FOR SUMMER) SOIL AMENDMENTS: INSPECT INLETS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (112 INCH OR GREATER) SEEDING MIXTURE: APPLY LIME AND FERTILIZER ACCORDING TO SOIL TEST, OR APPLY 3,000 - 5,000 LB. /ACRE GROUND AGRICULTURAL RAINFALL EVENT. CLEAR THE MESH WIRE OF ANY DEBRIS OR OTHER OBJECTS TO PROVIDE SPECIES RATE (LB. /ACRE) LIMESTONE (USE THE LOWER RATE ON SANDY SOILS) AND 1,000 LBJACRE 10 -10 -10 FERTILIZER. REP NOTT TDAMAGEEE UNDERCUT THE WIRE MESH DURING THE SEDIMENT REMOVAL. REPLACE STONE AS NEEDED. THE WIREM MESH DURING THE SEDIMENT REMOVAL. . NTS GERMAN MILLET 40 MULCH: APPLY 4,000 LB. /ACRE GRAIN STRAW OR EQUIVALENT COVER OF ANOTHER SUITABLE MULCH. ANCHOR STRAW BY A SMALL - STEMMED SUDANGRASS MAY BE SUBSTITUTED AT A RATE OF 50 LBJACRE. TACKING WITH ASPHALT, NETTING, OR ROVING OR BY CRIMPING WITH A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. 6 GENERAL EROSION AND SEDIMENT CONTROL NOTES 7 HARDWARE CLOTH & GRAVEL INLET PROTECTION SEEDING DATES: MAY 1 - AUGUST 15 MAINTENANCE: IF GROWTH IS LESS THAN FULLY ADEQUATE, REFERTILIZE IN THE SECOND YEAR, ACCORDING TO THE SOIL TESTS OR DRIVE STEEL POSTS 18" INTO THE GROUND ATTACH WIRE FENCE TO POSTS AND EXTEND NOTES: SOIL AMENDMENTS: TOP DRESS WITH 500 LBJACRE 10 -10 -10 FERTILIZER. MOW AS NEEDED WHEN SERICEA IS OMITTED FROM THE MIXTURE. DESIGN CRITERIA MAXIMUM a' o.c. AND ExcnvnrE A 4'X 8" THE BorroM of THE FENCE a" INTO rHE TRENCH UPHILL ALONG THE LINE OF EXCAVATED TRENCH AND TURNED OUT FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB. /ACRE GROUND AGRICULTURAL LIMESTONE AND 750 RESEED, FERTILIZE, AND MULCH DAMAGED AREAS IMMEDIATELY. POSTS. 4" IN THE TRENCH. 1. WIRE SHALL BE A MINIMUM OF 32 INCHES IN WIDTH AND LB. /ACRE 10 -10 -10 FERTILIZER. AGGREGATE SIZE - USE 2 -3 INCH WASHED STONE TOP & BOTTOM STRAND SHALL HAVE A MINIMUM OF 6 WIRES WITH 12" STAY SPACING. DIMENSION OF GRAVEL PAD GRAVEL ENTRANCE SHALL BE 50 FEET MIN. 10 GA. WIRE 2. FILTER FABRIC SHALL BE A MINIMUM OF 36" IN WIDTH AND SEEDING SPECIFICATIONS MULCH: APPLY 4,000 LB. /ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. IN LENGTH AND 12 FEET IN WIDTH THICKNESS- 6 INCHES MINIMUM WITH 20 FOOT RADIUS AT EXISTING WIDTH 12 FT. MINIMUM OR FULL WIDTH AT ACCESS STEEL POSTS STAY WIRES SHALL BE FASTENED ADEQUATELY TO THE WIRE WITH #9 WIRE MIN. 12 -1/2 GA STAPLES 1 -1/2" LONG. FABRIC THAT DETERIORATESTO SUCH SEEDING MIXTURE: - ROADWAY POINTS OF THE VEHICULAR ENTRANCE AND EXIT LINE WIRES EXTENT THAT ITS EFFECTIVENESS IS REDUCED SHALL BE A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. AREA, WHICHEVER IS GREATER MIN. 12 -1/2 GA. REPLACED BY CONTRACTOR AT CONTRACTOR'S EXPENSE. MAINTENANCE: SPECIES RATE (LB. /ACRE) 36' -0" MIN 4' -0" 10' -0" 6'. LENGTH- 50 FT. MINIMUM. 3. STEEL POSTS SHALL BE A MIN. OF 5' HEIGHT AND SHALL BE REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE AND MULCH IMMEDIATELY FOLLOWING COMMON BERMUDAGRASS 40- 80(1 -2 LB. /1,000 FT2) LOCATION - LOCATE CONSTRUCTION ENTRANCES AND THE SELF FASTENER ANGLE STEEL TYPE. " EROSION OR OTHER DAMAGE. •,,, ., , „ „° , b} %,,.. ._ . EXITS TO LI MIT SEDIMENT FROM LEAVING THE SITE AND TO PROVIDE FOR MAXIMUM UTILITY BY ALL 'u; .,.,n 4. CONTRACTOR SHALL REVIEW SILT FENCE ONCE PER WEEK "• •z.,k„ • AND AFTER EACH RAINFALL OCCURRENCE. ANY NECESSARY SEEDING DATES: FILTER FABRIC CONSTRUCTION VEHICLES. AVOID STEEP GRADES 2 -3" WASHED STONE AND ENTRANCES AT CURVES IN PUBLIC ROADS. u REPAIRS OR CLEAN -UP TO MAINTAIN THE EFFECTIVENESS OF THE DEVICE SHALL BE MADE IMMEDIATELY. TEMPORARY SEEDING /MULCHING SPECIFICATIONS (FOR FALL) COASTAL PLAIN: APR.-JULY CONTRACTOR SHALL INSTALL ADDITIONAL GRAVEL SEEDING MIXTURE: GRAVEL CONSTRUCTION ENTRANCE CONSTRUCTION ENTRANCES NOT INDICATED ON THE PLANS ry.X 3 5. REMOVE DEPOSITED SEDIMENT ALONG THE FENCE TO SOIL AMENDMENTS: REQUIRED FOR STAGING AND /OR BORROW AREAS AND PROVIDE ADEQUATE STORAGE VOLUME AND TO REDUCE SPECIES RATE (LB. /ACRE) APPLY LIME AND FERTILIZER ACCORDING TO SOIL TEST, OR APPLY 3,000 LB. /ACRE GROUND AGRICULTURAL LIMESTONE MAINTAIN AT NO ADDITIONAL EXPENSE TO THE OWNER. PRESSURE ON THE FENCE AS NEEDED. RYE (GRAIN) 120 AND 500 LB. /ACRE 10 -10 -10 FERTILIZER. CONTRACTOR SHALL SUPPLEMENT AND MAINTAIN GRAVEL CONSTRUCTION ENTRANCES AT HIS EXPENSE UNTIL FINAL STEP 1 STEP 2 5. TEMPORARY MEASURE SHALL NOT BE REMOVED BY THE ACCEPTANCE. CONTRACTOR UNTIL THIS ACTION IS APPROVED BY AN NCDENR ATTACH THE FILTER FABRIC TO THE WIRE FENCE, BACKFILL THE TRENCH AND COMPACT THE SOIL REPRESENTATIVE. THE ACTION WILL APPROVED WHEN THE SEEDING DATES: AUGUST 15 - DECEMBER 30 MULCH: USE JUTE, EXCELSIOR MATTING, OR OTHER EFFECTIVE CHANNEL LINING MATERIAL TO COVER THE BOTTOM OF OP / EXTEND THE BOTTOM OF THE FABRIC 8" INTO THE FIRMLY TO ANCHOR THE BOTTOM OF THE SILT CONTRIBUTING DRAINAGE AREA IS STABLE. TRENCH AND TURNED OUT 4" IN THE TRENCH. FENCE. BURIED FABRIC SHALL NOT BE VISIBLE. CHANNELS AND DITCHES. THE LINING SHOULD EXTEND ABOVE THE HIGHEST CALCULATED DEPTH OF FLOW. ON CHANNEL SIDE SLOPES ABOVE THIS HEIGHT, AND IN DRAINAGES NOT REQUIRING TEMPORARY LININGS, APPLY 4,000 \G� MAINTENANCE SOIL AMENDMENTS: FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB. /ACRE GROUND AGRICULTURAL LIMESTONE AND 1,000 LB. /ACRE 10 -10 -10 FERTILIZER. LB. /ACRE GRAIN STRAW AND ANCHOR STRAW BY STAPLING NETTING OVER THE TOP. QJ MAINTAIN THE GRAVEL PAD INBA CONDITION TO PREVENT MUD OR ' SEDIMENT FROM LEAVING THE CONSTRUCTION SITE. THIS MAY Posrs MAX a' O.C. WIRE FENCE "HOG WRE" �"` MULCH AND ANCHORING MATERIALS MUST NOT BE ALLOWED TO WASH DOWN SLOPES WHERE THEY CAN CLOG DRAINAGE DEVICES. S REQUIRE PERIODIC TOPDRESSING WITH 2 -INCH STONE. AFTER EACH 0' /n, RAINFALL, INSPECT ANY STRUCTURE USED TO TRAP SEDIMENT AND _- w A FILTER FABRIC ' '^� i E MULCH: APPLY 4,000 LB. /ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. CLEAN IT OUT AS NECESSARY. IMMEDIATELY REMOVE ALL OBJECTIONABLE MATERIALS SPILLED, WASHED OR TRACKED ONTO 1 1"„;' -,.,,, . ( ¢ #9 WIRE STAPLES 1 -1/2" LONG A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE: A MINIMUM OF 3 WEEKS IS REQUIRED FOR ESTABLISHMENT. INSPECTION AND REPAIR MULCH FREQUENTLY. Pueuc ROnownvs. ;. T �,; „� d : �� .,,�� ;" F BOTTOM OF WIRE FENCE AND &' _ } }p = FILTER FABRIC BURIED 8" IN { T w EXCAVATED TRENCH &TURNED REFERTILIZE THE FOLLOWING APR. WITH 50 LB. /ACRE NITROGEN. { = OUT 4" IN THE TRENCH MAINTENANCE: ' .: .. SLOW REPAIR AND REFERTILIZE DAMAGED AREAS IMMEDIATELY. TOP DRESS WITH 50 LB. /ACRE OF NITROGEN IN MARCH. IF E IT IS NECESSARY TO EXTEND TEMPORARY COVER BEYOND JUNE 15, OVERSEED WITH 50 LBJACRE KOBE LESPEDEZA i.,. ... ,I IN LATE OR EARLY MARCH. STEEL POST DRIVEN za "INro GROUND AGGREGATE �`L A 6" MIN. THICKNESS STEP STEP SECTION A -A MAINTENANCE 2 -3" COURSE 1. INSPECT SEDIMENT FENCES AT LEAST ONCE A WEEKAND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. 2. SHOULD THE FABRIC OF A SEDIMENT FENCE COLLAPSE, TEAR, DECOMPOSE OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. 3. REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE NTS PRESSURE ON THE FENCE. TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT. NTS 4. REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED AND NCDENR APPROVES REMOVAL. 4 TEMPORARY SEEDING SPECIFICATIONS 5 PERMANENT SEEDING SPECIFICATIONS 8 TEMPORARY GRAVEL CONSTRUCTION ENTRANCE 9 SILT FENCE 1/8" RADIUS �{ 1/8" � ---- �JOINT SEALER 1/8" TO 1/4" �. 4" ~n 4" 4 1.. 1/2" JOINT FILLER GROOVE JOINT IN SIDEWALK TRANSVERSE EXPANSION JOINT IN SIDEWALK 5' ASPHALT 5" THICK CONC. SIDEWALK q . 4 ar " f NOTE: 1. PROVIDE CONTROL JOINTS AT DISTANCE EQUAL TO WIDTH OF SIDEWALK, PROVIDE 1/2" EXP. JOINTS WITH PRE - MOLDED E.J. FILLER AT MAX. 30' O.C. 2. CONCRETE COMPRESSIVE STRENGTH SHALL BE 3000 PSI. NTS IN 28 DAYS. 10 CONCRETE WALK 409 Chicago Drive - 5uife 112 Fayeff iLe, NorEh Carolina 28506 Phone: (910) 426 -6777 Fax: (910) 426 -5777 License Number: C -2554 4P 51TL bOLUTIONb, INC A ENGINEL P-NG A 2VEYING A, GP_') A, CON')TP_L1Ci1ON LAYOLIT A REVISIONS PROJECT NAME FOREST RIDGE ACCESS & UTILITY ROAD SITE AND EROSION CONTROL DETAILS CLIENT ODELL A. SMITH PROPERTIES, LLC. 400 Odell Road Spring Lake, North Carolina 28390 Phone: (910) 497 -2020 Fax: (910) 497 -0569 PROJECT INFORMATION DESIGNED BY: BEN DRAWN BY: BEN CHECKED BY: SCOTT PROJECT NUMBER: 512 DRAWING SCALE NOT TO SCALE DATE RELEASED SEPTEMBER 27, 2012 SHEET NUMBER C -5.0 FINISHED GRADE 2„ r NOTES: AS NOTED ON PLANS EXISTING "xi` 1. CONCRETE SHALL BE 3,000 PSI MIN. ROAD ROAD SHOULDER BRASS MARKER PLATE MARKED PLATE 1 "X BACKFILL TO EDGE m 2. CONCRETE FOR THRUST BLOCKING SHALL BE KEPT WITH ANCHOR FAIRLY DRY, THUS MAKING THE CONCRETE WEDGE SHAPE MORE EASILY FORMED WITH THE WIDEST WATER DETAILS 3/4" CHAMFER AT I PART (BLOCKING AREA) AGAINST UNDISTURBED SOIL. 3. NO CONCRETE SHALL COVER ANY BOLTS OR GLANDS. ? V EA. CORNER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ................ e 4. ALL PIPING AND ACCESSORIES TO BE WRAPPED WITH 10 MIL. POLYETHYLENE PRIOR TO POURING z BACKFILL AS � m M 1 " CAST THE LETTERS MV IN BLOCKING. INDICATED X m;„ ONE FACE OF THE CONCRETE 4 #3 BARS PRECAST CONCRETE 5. VOLUME OF THRUST BLOCKING SHALL BE AS SHOWN o Z io a 1 cv r� MARKER AND ORIENT TOWARD PROTECTION RING ON THE THRUST BLOCKING SCHEDULE. ;� o �'" THE ROADWAY J z X I � w o N 45° BEND ROTATE MARKER TO OTHER END =_ En NEW WATER LINE SERVICE LINE TO FOR BLOW —OFF N °a CORPORATION METER CONNECTION X SERVICE SADDLE — A.Y. MCDONALD COCK —A.Y. MCDONALD STYLE HINGED 3891 FOR 3/4" VALVE NO. SERVICE SADDLE — A.Y. MCDONALD 8 12p TRENCH WIDTH 4" SQ. PRECAST CONC. CLIENT 25 FT. " 6 MIN. PIPE O.D. + 18" FOR PIPES UNDER 33" O.D. POST (4000 P.S.I.) m PIPE O.D. + 24" FOR PIPES OVER 33" O.D. NOTE: PLATE WITH VALVE NUMBER, DIRECTIONAL ARROW— POINTED ODELL A. SMITH 1. "SERVICE CONNECTION" IN PROPOSAL TO INCLUDE SERVICE SADDLE, TO MARKED VALVE & DISTANCE VALVE BOX VALVE OPERATOR NUT BEND, CORPORATION COCK AND ALL LABOR INVOLVED IN TO THE NEAREST FOOT. MAKING A COMPLETE SERVICE CONNECTION. MA PROPERTIES, I.I.C. A A 2. SERVICE PIPING TO BE 3/4" COPPER OR POLYETHELENE (SEE SPECS) 6" MIN. � 3. ALL BRASS FITTINGS SHALL BE COMPRESSION TYPE A X q NTS NOTES: NTS NTS PAINT MARKER BLUE AFTER INSTALLATION X HYDRANT TEE 400 Odell Road g TYPICAL WATER SERVICE CONNECTION 9 TYPICAL VALVE MARKER DETAIL 10 TYPICAL VALVE BOX DETAIL MIN.1 /3 C.Y. AT 3000 P.S.I. PLAN TEES Spring Lake, North Carolina 28390 a Phone: (910)497-20ar N PLAN BENDS Fax: (910) 497 -0569 N 18" MIN. O VALVE BOX • J 6 " -8" EXCESS LOOPED IN PLACE EMPTY VALVE BOX ALS WHERE TRACER WIRE BOX VALVES DO NOT OCCUR &APLACERTRACER WIRE PROJECT INFORMATION m ° NOTE: NO 1 EXISTING STORM SEWER cn cn r DRILL HOLE PRECAST CONCRETE PROTECTION RING IN VALVE BOX BACKFILL TO EDGE DESIGNED BY: BEN • a _ FOR TRACER WIR FINISHED GRADE 24 MIN. DRAWN BY: BEN — 18" MIN. — 10" O OR LESS 21 •• i ;;, SCOTT 24" MIN. — 12" O OR LESS.. ®.� . ...Il..:i„ —= ............ 111.I 5 PROJECT NUMBER: " NOTE. ENCASEMENT AREA TO INCLUDE Q AT PIPE INTERSECTIONS, MULTIPLE DUCTILE IRON PIPE ONLY z VALVES, RUN WIRE UP AT ONLY VALVE BOX VALVE BOX o ONE VALVE. ° SINGLE 12 AWG SOLID CORE WIRE 0 WATER MAIN PIPE 90° BEND 45° BEND 221/2° BEND 11/4° BEND TEE PLUG ui NOT TO SCALE SIZE A B A B A B A B A B C D o N N 4" 8" 12" 8" 8" 6" 6" 6" 6" 8" 9" 10" 16" 6" 10" 12" 8" 10" 8" 8" 8" 8" 10" 10" 12" 18" P.V.C. PIPELINE 8" 15" 13" 10" 10" 8" 8" 8" 8" 10" 12" 12" 24" 6 LENGTH OF ENCASEMENT TO BE STORM SEWER 10" 16" 14" 10" 12" 6" 10" 6" 10" 11" 14" 14" 25" 9 TRACER WIRE TO BE LAID �_ GATE VALVE 2IP 0" PORSAS DSHOWN DATE RELEASED 12" 20" 16" 12" 14" 8" 12" 8" 12" 14" 16" 16" 30" N UNDERNEATH WATER LINE ON PLANS. 14" 22" 18" 14" 16" 10" 14" 10" 14" 16" 18" 18" 34" SEPTEMBER 27, 2012 16" 26" 20" 16" 18" 12" 16" 12" 16" 18" 20" 20" 36" a a� NOTES: SHEET NUMBER i 1. DRILL HOLE IN VALVE BOX TO INSERT TRACER WIRE,BRING UP TO INSIDE AND ROLL UP AT LEAST 6 " -8" EXCESS 2. PLACE TRACER WIRE IN VALVE BOX AT 1,000" INTERVALS OR AS NOTED ON THE PLANS, TYPICAL N co NTS3 BRASS SCREW TO THE VALVEEBOX.ING A NEW SPOOL. INSTEAD INSTALL A VALVE BOX AND ATTACH EACH WIRE WITH A NTS NTS -5ml 7 THRUST BLOCK DETAIL 11 TYPICAL TRACER WIRE INSTALLATION 12 TYPICAL STORM SEWER CROSSING DETAIL co 0 N O rn J Q W 0 N U 409 Chicago Drive - 5uife 112 Fayeff iLe, NorEh Carolina 28506 Phone: (910) 426 -6777 Fax: (910) 426 -5777 License Number: C -2554 4P 51TL o�u ION � T b• INC A ENgNEE2ING A 2VEYING A, GP_') A, CON')T2L1CI0N LAYOLIT A REVISIONS PROJECT NAME FOREST RIDGE ACCESS & UTILITY ROAD SEWER DETAILS CLIENT ODELL A. SMITH PROPERTIES, LLC. 400 Odell Road Spring Lake, North Carolina 28390 Phone: (910) 497 -2020 Fax: (910) 497 -0569 PROJECT INFORMATION DESIGNED BY: BEN DRAWN BY: BEN CHECKED BY: SCOTT PROJECT NUMBER: 12" 10344 GENERAL NOTES: HAND PLACED DENSELY COMPACTED 1. ALL FIELD WIRING CONNECTIONS BETWEEN PUMPS, FLOAT SWITCHES AND CONTROL PANEL SHALL BE MADE BY LICENSED ELECTRICIAN ELECTRICIAN. O O O O BACKFILL TO 1 FT. �,\ \v ��7p 2. P.V.C. END CAP GLUED TO ELBOW AND Sys" O 1%$' O ABOVE TOP OF PIPE ; £ ..... ....... ....... ...... f PERFORATED WITH 16 EA. 0.12" DIA. HOLES MAY BE O O .. USED IN LIEU OF THE BIRD SCREEN. BEDDED PIPE PIPE O.D. FWD 3. RUN FLOAT SWITCH WIRES TO TERMINAL STRIP IN JUNCTION BOX D/4 FROM WETWELL AND FROM JUNCTION BOX TO CONTROL PANEL. MINIMUM STONE EMBEDMENT AS _ � � D/8 >_3 4. ALL ENCLOSURES SHALL BE NEMA 4X STAINLESS STEEL. INDICATED. GREATER IF REQUIRED BY s--�� 5. WIRE SIZE AND CONDUIT SIZE MAY VARY DEPENDING UPON PUMP REQUIREMENTS BUT 1" CONDUIT SHALL BE MIN SIZE. COPOLYMER POLYPROPYLENE MANUFACTURER IT Y2 PIPE 6. PUMP STATION BASE TO BE MANFACTURED SPECIFICALLY FOR PLASTIC M.A. INDUSTRIES MODEL SHAPED STONE O.D. DIRECT MOUNTING TO OPEN TOP, 6' DIA. MANHOLE AND PSI -PF OR APPROVED EQUAL. TO PROVIDE BEARING 24" + O.D. MAX. SHALL BE PROVIDED WITH ALL MOUNTING HARDWARE AND ANCHOR BOLTS. ANCHOR BOLTS SHALL BE HARDENED ALLOY, ALONG ENTIRE LENGTH 12" + O.D. MIN. 5/8" DIA. OF PIPE BARREL SANITARY SEWER 9y81 7. CIRCUITS SHALL BE IN DIRECT BURIED RIGID STEEL CONDUIT (0' -8' DEPTH) A MINIMUM OF 18" BELOW FINISHED GRADE. PIPE LAYING FRAME & COVER 8. COORDINATE GENERATOR RECEPTACLE WITH OWNER. 1y4" 3Y8 CONDITION "A" 23.5" NTS NTS 2" 1 3 GENERAL NOTES 4 POLYPROPYLENE PLASTIC STEP HAND PLACED DENSELY COMPACTED -I 1 ......I ........................y ' COVER BACKFILL TO 1 FT. — — — .......... ABOVE TOP OF PIPE L...f.# .... ........ ........ .......... ......................BEDDED PIPE ®PIPE FINISHED GRADE USE MIN. 4 EA. 3/8" ANCHOR NOTE: NOTE: — - O: D. BOLTS TO SECURE FRAME TO MANHOLE 1. THE FLOW CHANNEL THROUGH MANHOLES SHOULD BE MADE V inside EASEMENT SHALL BE PROVIDED FOR SERVICE D/2 D/8?3" TO CONFORM IN SHAPE AND SLOPE TO THE SEWER MAIN. RW CONNECTION WHERE SERVICE CONNECTION IS PLACED CAST IRON VALVE BOX MINIMUM STONE 1.5" MIN. 2. CHANGE IN DIRECTION OF THE CHANNEL SHALL NOT BE OUTSIDE OF R/W DUE TO PHYSICAL CONSTRAINTS. W/ CHARLOTTE HUB EMBEDMENT AS i - EXCEED 90 DEGREES. INDICATED. GREATER IF � BASE COURSE BASE COURSE 3. SEE DETAIL S -24 FOR TYPICAL MANHOLE STRUCTURE. ( REQUIRED BY 11nY in. STD. MANHOLE ' BRASS PLUG AND CAP MANUFACTURER RING & COVER 6" MIN X2 PIPE SHAPED STONE O.D. TO PROVIDE BEARING 24" + O.D. MAX., x ...... ALONG ENTIRE LENGTH 12" + O.D. MIN. I�IW____E RAM -NEK ; ;I...... ........,1 ' OF PIPE BARREL SANITARY SEWER SEALANT COMPACTED FILL COMPACTED FILL 4" PVC VERTICAL (<$' -16' DEPTH) � . �; SCH 40 PVC VERTICAL PIPE LAYING 3 0 MAX. CONDITION "B" NOTE: �O 4" SWEEP WYE STOP AT R/W SCH 40 PVC FRAME CONCRETE ENCASEMENT SHALL ONLY BE SLOPE SERVI CE LINE USED IN AREAS WHERE COVER IS TO BE FLUSH 1y� SCH PVC WITH PAVEMENT OR CONCRETE. CONCRETE 45° SANITARY TEE IN -LINE WYE ENCASEMENT SHALL NOT BE USED IN (SAME MATERIAL FITTING FOR NEW NON - TRAFFIC AREAS AND ABOVE GRADE AS MAIN) CONSTRUCTION OR INSTALLATIONS. ROMAC -CB SADDLE PLUG FOR TAP ON EXISTING s, Ooh (DO NOT GLUE) SANITARY SEWER MAIN. TEE BRANCH SLOPE MIN. 1% SANITARY SEWER MAIN NTS NTS NTS NTS 1 PIPE LAYING CONDITION 2 STANDARD MANHOLE FRAME & COVER 5 MANHOLE INVERT 6 SEWER SERVICE CONNECTION NOTE: IN NON - TRAFFIC AREAS,TOP OF FRAME AND COVER SHALL BE INSTALLED AT LEAST 2 FT ABOVE FINISH GRADE OR AT LEAST 1 FT ABOVE FLOOD STAGE. TRENCH WALL STANDARD MANHOLE RING AND COVER EXISTING WATER LINE USE 4 EA. 3/" ANCHOR BOLTS TO BOLT FRAME TO SPACER. 8" USE ROPE MASTIC SEAL BETWEEN FRAME AND SPACER. 8" MAX. FOR SPACER 2-0",3-0" MANHOLE STEPS OR 4' -0" 16" O.C. ECCENTRIC SEE DETAIL S -25 TAPER UNIT 24" MIN. CLEARANCE JOINTS SHALL BE SEALED s WITH A RUBBER O -RING - D.I. SANITARY — GASKET OR ROPE MASTIC SEAL. SEWER CEMENT GROUT ALL JOINTS INSIDE AND OUT E EE. ..............E EE r. S RISER UNIT 4' DIA. MIN. 5" 1yZ':12" SLOPEr } t } 8" MIN. X ON ALL INVERTS BASE UNIT }.. }....t:... r L }..tx ... *.." i....✓ "- Y'. " "� Y '• .. i.....;•a -tiY. 8-'-- UNDISTURBED SOIL EXTENDED BASE BRICK & MORTAR INVERT I 1 """' 'v I"" (REQUIRED OVER 12'). 40 12" MIN. 12" MIN. MIN. UNIFORM STONE #57 NOTE: WIDTH A 1 EA. JOINT OF DUCTILE IRON PIPE SHALL BE CENTERED REQUIRE UNDERWATER LINE FOR ALL CROSSINGS. MIN. 6" GRAVEL BEDDING NOTES: 1. SEE DETAIL S -28 FOR TYPICAL INVERT. NTS NTS 7 STANDARD PRECAST CONCRETE MANHOLE 8 WATER LINE CROSSING FOR SANITARY SEWER 409 Chicago Drive - 5uife 112 Fayeff iLe, NorEh Carolina 28506 Phone: (910) 426 -6777 Fax: (910) 426 -5777 License Number: C -2554 4P 51TL o�u ION � T b• INC A ENgNEE2ING A 2VEYING A, GP_') A, CON')T2L1CI0N LAYOLIT A REVISIONS PROJECT NAME FOREST RIDGE ACCESS & UTILITY ROAD SEWER DETAILS CLIENT ODELL A. SMITH PROPERTIES, LLC. 400 Odell Road Spring Lake, North Carolina 28390 Phone: (910) 497 -2020 Fax: (910) 497 -0569 PROJECT INFORMATION DESIGNED BY: BEN DRAWN BY: BEN CHECKED BY: SCOTT PROJECT NUMBER: 512 DRAWING SCALE NOT TO SCALE DATE RELEASED SEPTEMBER 27, 2012 SHEET NUMBER C -5.2 a O O N O m N 0 N J Q W 0 m v vM z N00 o7�o =a = =Z>M Z =oO� M * qz NO Z M Z W y _ _ 0 co = D v C 2 v M> CO) Z ZO n O X BACK OF CURB X12 SECTION Y -Y RISER HT. VARIES 8" MIN. ........... \NI-IFRF' n" Tnl R" PIPE IC I ICFf1 FRAME. GRATE AND HOOD b TOP ELEVATION 6" B T E o..... 8 8" D 771- MIN. MIN. 6" MIN. SECTION J -J WHERE 30" TO 36" PIPE IS USED NOTES: MORTAR JOINTS 1/2 "± 1/8" THICK. USE CLASS "B" CONCRETE THROUGHOUT. 4 USE FORMS FOR CONSTRUCTION OF THE BOTTOM SLAB. DEDUCT FOR PIPE(S) FROM TOTAL CU. YDS. OF BRICK MASONRY. USE #4 BAR DOWELS AT 12" CENTERS. PROVIDE ALL CATCH BASINS OVER 3-6" IN DEPTH WITH STEPS 12" ON CENTER. USE STEPS WHICH COMPLY WITH STD. DRAWING 840.66. USE TYPE "E ", "F" AND "G" GRATES UNLESS OTHERWISE INDICATED. USE BRICK OR CONCRETE BLOCK WHICH COMPLIES WITH THE REQUIREMENTS OF SECTION 840 OF THE STANDARD SPECIFICATIONS. IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF BOX, ADD TO SLAB AS SHOWN ON STD. NO. 840.00. FOR 8' -0" IN HEIGHT OR LESS, USE 8" WALL. OVER 8' -0" IN HEIGHT, USE 12" WALL TO 6-0" FROM TOP OF WALL AND 8" WALL FOR THE REMAINING 6' -0 ". QUANTITIES TO BE ADJUSTED ACCORDINGLY. CONSTRUCT WITH PIPE CROWNS MATCHING. CHAMFER ALL EXPOSED CORNERS 1 ". DRAWING NOT TO SCALE. WHERE 42" TO 54'' ' ' PIPE IS OTE z 000) QaQ Z OQaOZ WaZ == LL a goo W NH1�-zJ 00FA- za> 1 0° w O LL Z Z y m a Z V _ ~ Y N T c �MM W Z W TOP ELEVATION TOP ELEVATION M Y, z 1 - - p W W r J� B,!" E A W W N N SECTION Y -Y 6" c 6" _ Z d _ 0 Z D :' D ° Q a RISER HT. I ° C D VARIES + 'a= v 6" T SECTION J J Q Q H W WHERE 30' TO 36 PIPE IS USED r 4� U N M ��w C� "r. n` SEE NOTE SECTION M -M N 04 N Z WHERE 30" TO 36" PIPE IS USED WHERE 42" TO 54" PIPE IS USED co Ye ZG) RISER HT V T VARIES J - - - -- - - - -- J J M o M W m B 6.. A N: a; A WHERE 42" TO 54" PIPE IS USED 1 1 DETAIL SHOWING METHOD SHEET 1 OF 2 OF RISER CONSTRUCTION PLAN PLAN ISHEET 1 OF 2 840.02 1840.02 CONCRETE CATCH BASIN NTS v °m O� 10 z 43' NOTE: USE TYPE "E", "F" AND "G" GRATE v Q Q Q Op UNLESS OTHERWISE NOTED. N P P J= V mO��p=D B 0=jLxz rA G)�Zym �� HvzLLo Z G) 'v p 0 2 1/8" I I 2 1/8" Q Z W IF Ny1 N `��I --z X O E SECTION - LL SECTION - MM 0055 0 9 ? D O NZ A A ALIGN FRAME WITH INSIDE 2 3/8„ W "' EDGE OF WALL TO ALLOW ° Z °a °� FOR VERTICAL ADJUSTMENT 1.1„ _ ° a E� WALL SECTION I � D O SECTION - BB T T B SECTION - PP SECTION - NN -n PLAN " Z R1 FRAME, GRATE, & HOOD ASS'Y N N 3/4" LL 0 0 M 6.. 2, 0„ 6.. - z =v om= L) LID 3' 0" 1 3/4" 13/4" 0 Z U zK -K N N 13/4" ° °' �Wo o m� L M > N a SECTION -AA IE. z v z Q > z L -0-- M V 11-- U) z n J FRAME PLAN N = O Z N SECTION - JJ W 12 = 0 3/4" 3/4" 3-0 7/8" 5 5/8" U Jn � W 0 In 11/16" 1121 1/2" V LL > 0 0 I � I R 3" R z LL U. Z MJ- ` c > N O 11/2.. 6.. 2. 0.. 6.. 1/? I 1/2" N 6„ 6„ 3/4" 3 41/2� 3' 0" 3 1 /2" 3/4" O 4 3/4" 1/2.. /2" SECTION - KK 2' -11 1/2' 4 5/8" SHEET 1 OF 2 R SHEET 1 OF 2 840.03 HOOD ELEVATION SECTION - RR 840.03 FRAME, GRATES, AND HOOD NTS v Do S--"-] ��z y00 s° Z --I -i CO) #4 BARS "V„ I 6" 6" M 0 X-111 @3 EQUAL SPACES moo �{I oO-n DD Z D R "' co R "' co a ? 0- CO) �U U) U) LL Z m� mD u0 u0 in co @ S� PLAN OF TOP SLAB SECTION S -S M Z W CO) N `+ CO) 8" E #8 "W' BARS #4 BAR D #4 BARS "V" 6" 0 Zv @3 EQUAL SPACES - c-1> X. 0 a T v #4 BARS "U" 1 1/2" 6 "- -0 D SECTION R -R DOWEL y_ Z ZO O /� EXPANSION JOINTS 4' -6" 4' -6" STD. 840.03 FRAME GRATE & HOOD ����� R PLAN CURB AND GUTTER WITH CATCH BASIN ON STEEP GRADES TOP ELEVATION FANXD ANSION JOINT USE ON FLAT GRADES 2 UNDE R 3' -0" 3' -0" -DEPRESSED GUTTER LINE EXPANSION JOINT f � ELEVATION NORMAL CURB AND GUTTER ON LIGHT GRADES TOP ELEVATION NORMAL GUTTER LINE 8 6„ EXPANSION JOINT USE OVGR�DES % 6,_0„ EXPANSION JOINT DEPRESSED GUTTER LINE ELEVATION NORMAL CURB AND GUTTER ON STEEP GRADES MINIMUM DIMENSIONS AND QUANTITIES FOR BRICKCATCH BASIN (BASED ON MIN. HEIGHT, H, WITH NO RISER)* WHERE 42" TO 54" PIPE IS USED J- + 5 Ig J- 1L- L -fit 8, TOP SLAB DIMENSIONS ZX DETAIL SHOWING METHOD OF RISER CONSTRUCTION PLAN PLAN BRICK MASNARY SHEET 1 OF 2 SHEET 1 OF 2 840.01 840.01 BRICK CATCH BASIN NTS v v 0 BACK OF FRAME GRATE AND HOOD GENERAL NOTES: CURB SEE STD. NO. 840.03 USE CLASS "B" CONCRETE THROUGHOUT. Z 0 -I z TOTAL :\f- PROVIDE ALL CATCH BASINS OVER 3' -6" IN DEPTH WITH STEPS 12" BOTTOM SLAB T N O 0 BRICKMSNR. IN WALLS 5 ON CENTER. USE STEPS WHICH COMPLY WITH STD. DRAWING 840.66. _ Z -nTOP B ELEVATION OPTIONAL CONSTRUCTION - MONOLITHIC POUR, 2" KEYWAY, OR #4 BAR DOWELS AT 12" CENTERS AS DIRECTED BY THE ENGINEER. J 0 r Z Y * Y lj LL 0 Z p i11 0 = D n A L - - USE FORMS FOR CONSTRUCTION OF THE BOTTOM SLAB. N = = W TI zD ill LBS. IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF BOX, ADD TO SLAB CO ro AS SHOWN ON STD. NO. 840.00. Q Z Q (.i Q O 12" 3' -0" 2' -2" ��/ 5-000 Z 2' -9" 6 B 6" = USE TYPE "E ", "F" AND "G" GRATES UNLESS OTHERWISE INDICATED. � _ Z J N = 0 L- FOR 8' -0" IN HEIGHT OR LESS, USE 6" WALLS AND BOTTOM SLAB. OVER D p - Z 0.281 8' -0" TO 16' -0" IN HEIGHT, USE 8" WALLS AND BOTTOM SLAB. ADJUST 0 0 rn D D D 0.281 QUANTITIES ACCORDINGLY. Z N 0.042 5 m CONSTRUCT WITH PIPE CROWNS MATCHING. ~ ° Z PLAN X 3. SEE NOTE CHAMFER ALL EXPOSED CORNERS 1 ". LU C �, �...... DRAWING NOT TO SCALE. L TOP ELEVATION TOP ELEVATION M Y, z 1 - - p W W r J� B,!" E A W W N N SECTION Y -Y 6" c 6" _ Z d _ 0 Z D :' D ° Q a RISER HT. I ° C D VARIES + 'a= v 6" T SECTION J J Q Q H W WHERE 30' TO 36 PIPE IS USED r 4� U N M ��w C� "r. n` SEE NOTE SECTION M -M N 04 N Z WHERE 30" TO 36" PIPE IS USED WHERE 42" TO 54" PIPE IS USED co Ye ZG) RISER HT V T VARIES J - - - -- - - - -- J J M o M W m B 6.. A N: a; A WHERE 42" TO 54" PIPE IS USED 1 1 DETAIL SHOWING METHOD SHEET 1 OF 2 OF RISER CONSTRUCTION PLAN PLAN ISHEET 1 OF 2 840.02 1840.02 CONCRETE CATCH BASIN NTS v °m O� 10 z 43' NOTE: USE TYPE "E", "F" AND "G" GRATE v Q Q Q Op UNLESS OTHERWISE NOTED. N P P J= V mO��p=D B 0=jLxz rA G)�Zym �� HvzLLo Z G) 'v p 0 2 1/8" I I 2 1/8" Q Z W IF Ny1 N `��I --z X O E SECTION - LL SECTION - MM 0055 0 9 ? D O NZ A A ALIGN FRAME WITH INSIDE 2 3/8„ W "' EDGE OF WALL TO ALLOW ° Z °a °� FOR VERTICAL ADJUSTMENT 1.1„ _ ° a E� WALL SECTION I � D O SECTION - BB T T B SECTION - PP SECTION - NN -n PLAN " Z R1 FRAME, GRATE, & HOOD ASS'Y N N 3/4" LL 0 0 M 6.. 2, 0„ 6.. - z =v om= L) LID 3' 0" 1 3/4" 13/4" 0 Z U zK -K N N 13/4" ° °' �Wo o m� L M > N a SECTION -AA IE. z v z Q > z L -0-- M V 11-- U) z n J FRAME PLAN N = O Z N SECTION - JJ W 12 = 0 3/4" 3/4" 3-0 7/8" 5 5/8" U Jn � W 0 In 11/16" 1121 1/2" V LL > 0 0 I � I R 3" R z LL U. Z MJ- ` c > N O 11/2.. 6.. 2. 0.. 6.. 1/? I 1/2" N 6„ 6„ 3/4" 3 41/2� 3' 0" 3 1 /2" 3/4" O 4 3/4" 1/2.. /2" SECTION - KK 2' -11 1/2' 4 5/8" SHEET 1 OF 2 R SHEET 1 OF 2 840.03 HOOD ELEVATION SECTION - RR 840.03 FRAME, GRATES, AND HOOD NTS v Do S--"-] ��z y00 s° Z --I -i CO) #4 BARS "V„ I 6" 6" M 0 X-111 @3 EQUAL SPACES moo �{I oO-n DD Z D R "' co R "' co a ? 0- CO) �U U) U) LL Z m� mD u0 u0 in co @ S� PLAN OF TOP SLAB SECTION S -S M Z W CO) N `+ CO) 8" E #8 "W' BARS #4 BAR D #4 BARS "V" 6" 0 Zv @3 EQUAL SPACES - c-1> X. 0 a T v #4 BARS "U" 1 1/2" 6 "- -0 D SECTION R -R DOWEL y_ Z ZO O /� EXPANSION JOINTS 4' -6" 4' -6" STD. 840.03 FRAME GRATE & HOOD ����� R PLAN CURB AND GUTTER WITH CATCH BASIN ON STEEP GRADES TOP ELEVATION FANXD ANSION JOINT USE ON FLAT GRADES 2 UNDE R 3' -0" 3' -0" -DEPRESSED GUTTER LINE EXPANSION JOINT f � ELEVATION NORMAL CURB AND GUTTER ON LIGHT GRADES TOP ELEVATION NORMAL GUTTER LINE 8 6„ EXPANSION JOINT USE OVGR�DES % 6,_0„ EXPANSION JOINT DEPRESSED GUTTER LINE ELEVATION NORMAL CURB AND GUTTER ON STEEP GRADES MINIMUM DIMENSIONS AND QUANTITIES FOR BRICKCATCH BASIN (BASED ON MIN. HEIGHT, H, WITH NO RISER)* DIMENSIONS OF BOX AND PIPE TOP SLAB DIMENSIONS ZX CU. YDS. CONC. IN BOX BRICK MASNARY DEDUCTIONS ONE PIPE PIPE SPAN WIDTH WIDTH SPAN MIN. HEIGHT BAR BARS -V BARS -W TOTAL TOP SLAB BOTTOM SLAB TOTAL CONC. BRICKMSNR. IN WALLS TOTAL BRICKAND CONCRETE D A B C G H E F NO. LENGTH NO. LENGTH NO. LENGTH LBS. C.M. R.C. 12" 3' -0" 2' -2" 2' -9" 0.281 0.772 0.015 0.281 0.281 0.883 1.164 0.020 0.042 15" 3' -0" 2' -2" 3' -0" 0.281 0.829 0.023 0.036 18" 0.281 0.281 0.963 1.244 0.031 0.047 18" 3' -0" 2' -2" 3' -3" 0.281 0.887 0.033 0.049 24" 3' -0" 2' -2" 0.281 0.281 1.043 1.324 0.044 0.065 24" 3' -0" 2' -2" 3' -9" 0.281 1.001 0.059 0.085 30" 1 3--0-- 1 2 2' 3' -4" 0.281 0.281 1.204 1.485 0.078 0.121 30" 3' -0" 2' -2" 3' -4" 0.123 4' -3" V -2" 4' -4" 4 1' -6" 3 4' -1" 3 4' -1" 45 0.147 0.374 0.521 1.606 2.217 0.122 0.184 36" 3' -0" 2' -2" 3' -10" 1.714 4' -9" 1' -8" 4' -4" 4 2' -0" 4 4' -1" 3 4' -1" 49 0.187 0.415 0.602 1.914 2.516 0.176 0.261 42" 3' -0" 2' -2" 0.180 4' -5" 5'7 V -5" 3' -6" 4 1' -9" 3 3' -3" 3 3' -3" 38 0.135 0.373 0.508 2.152 2.660 0.240 0.371 48" 3' -0" 2' -2" 54" 5' -0" 5' -9" 2' -0" 3' -6" 4 2' -6" 4 3' -3" 3 3' -3" 41 0.173 0.410 1 0.583 1 2.415 1 2.998 1 0.313 0.477 54" 3' -0" 2' -2" 5' -7" 6' -3" 2' -7" 3' -6" 4 3' -0" 6 3' -3" 3 3' -3" 47 0.211 0.448 I 0.659 2.806 3.465 0.396 0.595 840.011 * RISER HAS .321 CUBIC YARDS OF BRICK MASONRY PER FOOT HEIGHT BRICK CATCH BASIN v vo S-111-1 ;Z.--1 z �I Copp 6" E I r z --I -i N #4 BARS "V" 6" 6" M 0 = D @3 EQUAL SPACES _ = Z D m 3„ 1 1/2" 1 1/2" 11 c oZ O (7 _ R U) R M U) CO) ?a ?a LL U) z ' Q < m u0 u0 S� PLAN OF TOP SLAB SECTION S -S OZ G) Z r CA TO = #4 BAR 6" E #8 "W' BARS D #4 BARS 'V' = M Z @3 EQUAL SPACES v C"Dv 6" #4 BARS "U" n L11 " M = SECTION R -R DOWEL W N -n TOP SLAB DIMENSIONS ZX CU. YDS. CONC. IN BOX DEDUCTIONS ONE PIPE HEET 2 OF 2 840.02 v vM Z Ln 00 �o� =a =xz>m Z=oO-n CO) z ( - EXPANSION JOINTS - 4' -6" 1 4' -6" DD�W�0���00 00���0�0�00 F� 6 -0" PLAN CURB AND GUTTER WITH CATCH BASIN ON STEEP GRADES TOP USE ON FLAT ELEV. EXPANSION JOINT GRADES 2% AND UNDER DEPRESSED GUTTER LINE 1 4 EXPANSION JOINT 3 -0 .1 o 13' -0" ELEVATION NORMAL CURB AND GUTTER ON LIGHT GRADES NORMAL GUTTER LINE EXPANSION JOINT 8" TOP USE ON GRADES OVER 2% ELEV. 10" I DEPRESSED GUTTER LINE EXPANSION JOINT �- I -I 6' -0" 1' -0" ti MAX M ELEVATION NORMAL CURB AND GUTTER ON STEEP GRADES MINIMUM DIMENSIONS AND QUANTITIES FOR BRICK CATCH BASIN (BASED ON MIN. HEIGHT, H, WITH NO RISER)* DIMENSIONS OF BOX AND PIPE TOP SLAB DIMENSIONS BEN CU. YDS. CONC. IN BOX DEDUCTIONS ONE PIPE PIPE SPAN WIDTH WIDTH SPAN MIN. HEIGHT BARS -U BARS -V BARS -W TOTAL TOP SLAB BOTTOM SLAB ToT.coNC FPR MINIMUM HECHT,H D A B C G H E F NO. LENGTH NO. LENGTH NO. LENGTH LBS. C.M. R.C. 12" 3' -0" 2' -2" 2' -9" 0.281 0.772 0.015 0.026 15" 3' -0" 2' -2" 3' -0" 0.281 0.829 0.023 0.036 18" 3' -0" 2' -2" 3' -3" 0.281 0.887 0.033 0.049 24" 3' -0" 2' -2" 3' -9" 0.281 1.001 0.059 0.085 30" 1 3--0-- 1 2 2' 3' -4" 4 3' 1'-2" 4--0-- 4 1 5' 2 3' -9" 3 3 9' 39 0.123 0.374 1.433 0.092 0.127 36" 3--0-- 2 2" 3-10" 4 9" 1'-8" 4--0-- 4 V -11" 3 3' -9" 3 3 9' 43 0.161 0.415 1.714 0.123 0.178 42" 3--0-- 2 2" 4' -5" 5 3" V-5" 3 2" 4 V-8" 2 2 -11" 3 2--11" 32 0.112 0.373 1.738 0.180 0.243 48" 3--0-- 2 -2" 5' -0" 5 -9" 2--0-- 3--2-- 4 2 -3" 3 2' -11 " 3 2'-11 " 35 0.145 0.410 2.052 0.235 0.317 54" 3' -0" 2' -2" 5' -7" 6' -3" 2' -7" 3' -2" 4 2' -10" 5 2' -11" 3 2' -11" 41 0.180 0.448 2.387 0.297 0.401 * RISER HAS .321 CUBIC YARDS OF BRICK MASONRY PER FOOT HEIGHT CONCRETE CATCH BASIN DETAILS SHOWNING TYPES OF GRATES USE ACCORDING TO WATER FLOW. TYPE "G" TYPE "E" TYPE "F" WATER FLOW SAG WATER FLOW f 2' -11 3/4" B A A 9 7/8" M 9 7/8" B 1 1/2" 5/8' t�� SECTION B -B z 0 c QaQ Z LLJO =() ppaOz WaZ == H0 LL (D =goo HII-- zJ LLog 00ra za> 1 0° w O LL Z Z N m a FL Z V _ ~ Y !V N r in �MM W z W 840.01 NTS z oy aaa LLJp =ci ppa(gZ N = WaZ = H()�LL(7 O W N H 1�- Z J 0055 za> 1 LU O ? (� Q Z m 2 a LLJ Q V H W 1.L r CO) Z �O Z (� W HEET 2 OF 2 840.02 NTS z ON aaa LL �0=ci ppa0z WaZ == H()gLL(7 O W �jHHzJ 0 0 vy zap 1 LU -'I 1 3/4" 2 1 /4" Z_ �z i WATER FLOW SAG WATER FLOW f Z o0a m LL ic SECTION A -A = = M CO) z c) ZM TYPE "F" TYPE "E" TYPE "G" TYPE - E O Q Z D RAISED FLOW ARROW 2 3/4" Q 0 z Z P 1/16" HIGH Zv D RAISED FLOW ARROW 2 3/4" I = W a D r11 1/16" HIGH 1 O Q Z V� v ' J- O D - N ° QQ Q v >v O MR 0 M zGC� CU 0 Z 1 1/2" N M 1 1/2" � U) z O `� _ 0 _ 0 1/8" 1/8" m J 2 w D o P 1 1/2.. N 1 3/4" Z q Ln o 1 1/2" 1/8" 1 1/2" R W LPL 0 1 3/4" � � 1/8" LL O z 2' -11 3/4" 2' -11 3/4" LL 1 1/2.. 7/8" 1 3/4" SECTION A -A II 7/8" SHEET 2 OF 2 TYPE - F 840.03 FRAME, GRATES, AND HOOD HEET 2 OF 2 840.03 NTS 409 Chicago Drive - 5uife 112 FayeffeviLe, NorEh Carolina 28506 Fax: (91091426 577/ 7 License Number: C -2554 \� 4P T boLUTloN ) INC ALNGINLLP -NG A.hL12VEYING A, GP-') A, C N.hTP-L1CTI0N LAYOLIT A REVISIONS PROJECT NAME FOREST RIDGE ACCESS & UTILITY ROAD STORM DETAILS CLIENT ODELL A. SMITH PROPERTIES, LLC. 400 Odell Road Spring Lake, North Carolina 28390 Phone: (910) 497 -2020 Fax: (910) 497 -0569 PROJECT INFORMATION DESIGNED BY: BEN DRAWN BY: BEN CHECKED BY: SCOTT PROJECT NUMBER: 512 DRAWING SCALE NOT TO SCALE DATE RELEASED SEPTEMBER 27, 2012 SHEET NUMBER C-5n3 LNC�INEE INS LAND .SUIZVEYIN� CON STIZUCTION LAYOUT (�P') CL VICL5 LAND DEVELOP)fAENT dog CNICA(;o DP-IVL SUITE 112 FAYETTEVI LLE NC 285o6 PNQN1- 910 A26 -61777 r FAX 910 426 -5777 4P,51TF- 50LUTION,5, INC. Forest Ridge Access Road Storm Water Narrative The site is currently undeveloped. The site is being developed as an access road for future commercial lots along NC Highway 87. The total disturbed area for the developed is 0.65 acres. The impervious area of the new street and sidewalk is 10,432 sf or 36.8% based on the total disturbed area. Because of the existing grades, the drainage from the access road ties into an existing storm system where it is impractical to treat, and there is no room available for treatment. This was discussed over the phone with Annette Lucas on August 16, 2012. In the next 18 months or so, a regional storm water pond will be sized to treat the commercial lots and the remainder of the future access road. At this time, the storm pond will be designed for 90% TSS removal in lieu of the minimum 85% in order to compensate for the untreated storm water from the access road in this portion of the project. r'iC"S ial8"9i 11�� 1=C�1� �"'.f 11aI�i�3I IC":ilt"9tal 1 -- RIGHT —OF —WAY f ss SANITARY SEWER LINE STORM DRAINAGE WATER LINE OVERHEAD UILITY EM ELECTRICAL METER FEB] ELECTRICAL BOX — —�— — ® MAILBOX PP • UTILITY POLE C GUY WARE ❑T TELEPHONE PEDESTAL ® DROP INLET S SANITARY SEWER MANHOLE N WATER VALVE FIRE HYDRANT T WATER METER i ® CATCH BASIN -co CLEANOUT 2 ) N /F ROGER ARNOLD BOYD AND WIFE, NANCY DALE BOYD DB 1027, PG 284 PC# F, SLIDE 200 —C ju- Know what's below. Call before you dig. VICINITY MAP NOT TO SCALE LINDEN OAKS SITE ece \ �e 0 � 1 ) N /F ROBERT T. RICE AND WIFE, RITA L. RICE DB 1040, PG 424 PC# F, SLIDE 200 —C �.... _ ......... . . . . . . . . . . . . . . . . . . . . . . . . . . . .............. . 1 I / I I �I I; r 1 l Y l .......... .. . . . ....... . . . ..... .... JjJ ... ......y ......................................... — — ......... .:: ... BEGINNING OF PROJECT i MELODY LANE ........... �....... 409 Chicago Drive - .hint, 112 fa i±eviLL, NM C_Llna 28306 Fc904 6s�� ���\\ L­, N mben c2354 ,. 4P ,5ITE b0L1LJT10N ,5, INc A.qN­q ANN VV NN ANNA A N-1oH —T A REVISIONS PROJECT NAME FOREST RIDGE ACCESS & UTILITY ROAD OVERALL SITE PLAN CLIENT ODELL A. SMITH PROPERTIES, LLC. 400 Odell Road Spring Lake, North Carolina 28390 Phone: (910) 497 -2020 Fax: (910) 497 -0569 PROJECT INFORMATION SURVEYED BY: / DRAWN BY: � t CHECKED BY: JIMMY PROJECT NUMBER: 512 C) \ N /F FOREST RIDGE SUBDIVISION, LLC DB 2383, N /509 I \ WETLAND IMPACT AREA (3,779 SF) I � L i i I $ � v .......... .. . . . ....... . . . ..... .... JjJ ... ......y ......................................... — — ......... .:: ... BEGINNING OF PROJECT i MELODY LANE ........... �....... 409 Chicago Drive - .hint, 112 fa i±eviLL, NM C_Llna 28306 Fc904 6s�� ���\\ L­, N mben c2354 ,. 4P ,5ITE b0L1LJT10N ,5, INc A.qN­q ANN VV NN ANNA A N-1oH —T A REVISIONS PROJECT NAME FOREST RIDGE ACCESS & UTILITY ROAD OVERALL SITE PLAN CLIENT ODELL A. SMITH PROPERTIES, LLC. 400 Odell Road Spring Lake, North Carolina 28390 Phone: (910) 497 -2020 Fax: (910) 497 -0569 PROJECT INFORMATION SURVEYED BY: RON DRAWN BY: SEAN CHECKED BY: JIMMY PROJECT NUMBER: 512 DRAWING SCALE HORIZONTAL: V=50' DATE RELEASED SEPTEMBER 26, 2012 SHEET NUMBER r� OF 2 LINDEN V OAKS SITE ce wxsa+ae \o e \oaf � � gmN VICINITY MAP NOT TO SCALE LEGEND: EIR OO EIR — EXISTING IRON ROD CID o CP— COMPUTED POINT N/F — NOW OR FORMERLY R/W — RIGHT OF WAY PVC — POLYVINYL CHLORIDE RCP — REINFORCED CONCRETE PIPE PROPERTY LINE — — — — CREEK WETLANDS WETLANDS IMPACT AREA IMPACT AREA PERMANENT WETLAND IMPACT. 3,779 SF DESCRIPTION Al THE ACCESS ROAD IS CROSSING THROUGH THE ENTIRE PORTION OF WETLANDS. THERE ARE A PROPOSED 18" STORM PIPE, 8" SEWER PIPE AND A 6" WATER MAIN IN THIS AREA. 305 300 295 290 285 IMPACT AREA IMPACT PROFILE 0 +50 TO 2 +50 1+00 2 +00 305 300 295 290 285 GRAPHIC SCALE 50 0 25 50 100 ( IN FEET ) 1 inch = 50 ft. 409 CH,ago Drive- .hulte 112 f'yeLteviLLe NM h CaroLlna 28306 f�(90426 -,,777 License Number G2354': 4D S11 TE`S 50LUTION-5, INc A ENgI—INq A —V-Ne k- kvN—ONwrour A REVISIONS PROJECT NAME FOREST RIDGE ACCESS & UTILITY ROAD STREAM IMPACT MAP CLIENT ODELL A. SMITH PROPERTIES, LLC. 400 Odell Road Spring Lake, North Carolina 28390 Phone: (910) 497-2020 Fax: (910) 497 -0569 PROJECT INFORMATION SURVEYED BY: RON DRAWN BY: SEAN CHECKED BY: JIMMY PROJECT NUMBER: 512 DRAWING SCALE HORIZONTAL: 1"=50' VERTICAL: 1"=5' DATE RELEASED SEPTEMBER 26,2012 SHEET NUMBER W -2 OF 2