Loading...
HomeMy WebLinkAboutNC0021369_Authorization to Construct_20130225NPDES DOCUMENT !;CANNINe COVER :SHEET Permit: NC0021369 Columbus WWTP NPDES Document Type: Permit Issuance Wasteload Allocation Authorization to Construct (AtC) Permit Modification Complete File - Historical Engineering Alternatives (EAA) Return Instream Assessment (67b) Speculative Limits Environmental Assessment (EA) Document Date: February 25, 2013 This document is printed on reuse paper - igprzore any content on the reYerse side 175 ATA NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Pat McCrory Charles Wakild, P.E. John E. Skvarla, III Governor Director Secretary Mr. Jonathan Kanipe Town of Columbus Post Office Box 146 Columbus, North Carolina 28722 February 25, 2013 SUBJECT: Authorization to Construct A to C No. 021369A04 Town of Columbus Columbus WWTP Improvements SRL Project No. E-SRL-T-11-0087 Dear Mr. Kanipe: A letter' of request for an Authorization to Construct was received February 21, 2013, by the Division of Water Quality (Division), and final plans and specifications for the subject project have been reviewed and found to be satisfactory. Authorization is hereby granted for the construction of modifications to the existing 0.8 MGD WWTP, with discharge of treated wastewater into an unnamed tributary of the White Oak River Basin. This authorization results in no increase in design or permitted capacity and is awarded for the construction of the following specific modifications: Installation of a 0.8 MGD (2.0 MGD peak) automated bar screen with a manual bypass bar screen; 0.8 MGD (2.0 MGD peak) grit removal system; a new redundant 45-ft diameter clarifier with 14-ft side wall depth and a loading rate of 252 gpd/ft2; two (2) new 300 gpm RAS/WAS pumps and flow monitors; one (1) new 233,000 gallon aerated sludge digester/holding tank with a 600 gpm sludge transfer''pump; and a 600 KW backup generator, in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources. This Authorization to Construct is issued in accordance with Part III, Paragraph A of NPDES Permit No. NC0021369 issued August 29, 2012, and shall be subject to revocation unless the wastewater treatment facilities are constructed in accordance with the conditions and limitations specified in Permit No. NC0021369. 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Location: 512 N. Salisbury St. Raleigh, North Carolina 27604 Phone: 919.807-63001 FAX: 919-807-6492 Internet: www.ncwateraualitv.orq MAR 0 4 2013 DENR-WATER QUALITY POINT SOURCE BRANCH One NorthCarolina Naturally An Equal Opportunity1 Affirmative Action Employer Mr. Jonathan Kanipe February 25, 2013 Page 2 The sludge generated from these treatment facilities must be disposed of in accordance with G.S. 143-215.1 and in a manner approved by the Division. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by the Division, such as the construction of additional or replacement wastewater treatment or disposal facilities. The Asheville Regional Office, telephone number (828) 296-4500, shall be notified at least forty-eight (48) hours in advance of operation of the installed facilities so that an on site inspection can be made. Such notification to the regional supervisor shall be made during the normal office hours from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with the NPDES Permit, this Authorization to Construct and the approved plans and specifications. Mail the Certification to: Infrastructure Finance Section, DWQ/DENR, 1633 Mail Service Center, Raleigh, NC 27699-1633. Upon classification of the facility by the Certification Commission, the Permittee shall employ a certified wastewater treatment plant operator to be in responsible charge (ORC) of the wastewater treatment facilities. The operator must hold a certificate of the type and grade at least equivalent to or greater than the classification assigned to the wastewater treatment facilities by the Certification Commission. The Permittee must also employ a certified back-up operator of the appropriate type and grade to comply with the conditions of T15A:8G.0202. The ORC of the facility must visit each Class I facility at least weekly and each Class II, III and IV facility at least daily, excluding weekends and holidays, must properly manage the facility, must document daily operation and maintenance of the facility, and must comply with all other conditions of T15A:8G.0202. A copy of the approved plans and specifications shall be maintained on file by the Permittee for the life of the facility. During the construction of the proposed additions/modifications, the permittee shall continue to properly maintain and operate the existing wastewater treatment facilities at all times, and in such a manner, as necessary to comply with the effluent limits specified in the NPDES Permit. You are reminded that it is mandatory for the project to be constructed in accordance with the North Carolina Sedimentation Pollution Control Act, and when applicable, the North Mr. Jonathan Kanipe February 25, 2013 Page 3 Carolina Dam Safety Act. In addition, the specifications must clearly state what the contractor's responsibilities shall be in complying with these Acts. Prior to entering into any contract(s) for construction, the recipient must have obtained all applicable permits from the State. Failure to abide by the requirements contained in this Authorization to Construct may subject the Permittee to an enforcement action by the Division in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. The issuance of this Authorization to Construct does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. One (1) set of approved plans and specifications is being forwarded to you. If you have any questions or need additional information, please contact Seth Robertson, P.E. at telephone number (919) 707-9175. -Charles Wakild, P.E. MM:sr cc: Bob Froneberger, P.E. - W K Dickson & Company, Inc. Pollc County Health Department DWQ Asheville Regional Office, Surface Water Protection DWQ Point Source Branch, NPDES Program Michelle McKay, E.I. SRL File