Loading...
HomeMy WebLinkAboutNC0076783_Inspection_20000331--C4vp44,A 11/6:100 13.0t NORTH CAROLINA DEPARTMENT OF ENVIRONMENT 'AND NATURAL RESOURCES DIVISION OF WATER QUALITY FAYETTEVILLE REGIONAL OFFICE Mardi 31, 2000 • Mr. M. Ncland Director of Water and Wastewater Resources Public Works Commission ofFayetteville PO Drawer 1089 Fayetteville, NC 2830R' SUBJECT: Compliance Evaluation Inspection PWC of Fayetteville, P. O. Hoffer WTF NPDES Permit No. NC0076783 Cumberland County Dear Mr. Noland: Enclosed is 'a copy of the random Compliance Evaluation Inspection conducted on March 28, 2000. , As part of the inspection, a tour of the Water Treatment Plant was conducted. All observations , and recommendations are in Part D. Summary of Findings/Comrnents of this inspection report. Remember, it is our goal to insure the , quality of the surface waters of this State. Please review the attached report. If you•or your staffhave any questions, do not hesitate to contact me at (910)486-1541. /hinw Enclosures cc: Central files DWQ NPDES Compliance Sincerely, Pt, 0' Hughie M. White.II Environmental Technician 2 0 I .-0" 225 GREEN STIIEET, SUITE 714./ SYSTEL BLD. FAYETTEVILLE, NORTH CAROLINA 28301-5043 PHONE 910-486-1541. FAX 910-486-0707 AN EQUAL OPPORTUNITY / AFFIRMATIVE ACTION EMPLOYER - 50% RECYCLED/10% POST -CONSUMER PAPER 7J NPDES COMPLIANCE INSPECTION REPORT North Carolina Division of Water Quality Fayetteville Regional Office Section A. National Data System Coding Transaction Code: N NPDES NO. NC0076783 Date: March 28,-2000 Inspection Type: C Inspector: S Facility Type: 1 Reserved: Facility Evaluation Rating: 4 BI: N QA: N Reserved. Section Br Facility Data Name and Location of Facility Inspected: P. O. Hoffer WTF; Fayetteville, Cumberland County Entry Time: 14:00 Permit Effective Date:960701 Exit Time/Date: 16:00 / 000328 Permit Expiration Date: 010531 Name(s), Title(s) of On -Site Representative(s): Mr. Kevin Christmas, .."ORC:" Grade IV , Phone Number(s): 910-483-1401 . Name, Title and Address of Responsible Official: Mr. M. J. Noland, Directorof Water and Wastewater Resources -Public Works Commission of Fayetteville - PO Drawer 1089 Fayetteville, NC 28302 - Contacted: no Section C: Areas Evaluated During Inspection (S = Satisfactory, M = Marginal, iJ = Unsatisfactory, N = Not Evaluated, N/A = Not Applicable ermif�y v:Sr. J: <i 4s = Re¢ordsa"�orts•�S�� ����4'r=::.:>x xe. - aclt� it'e•�R'eviewc �'S ' $_ vr' ��� 4..r. } �i5 .Flow- easureizien't'S� - Ste' ry; - o 5�;-� +zirl �aborat r' rY:� :A ;::��-em; fl'� -`t' `e�`ei`in:;Watcrs=`:��5:.>-•`�- ��Ef uen %R c v g sl ,etreatmen t: - :'`• om`Plianee-Schedule::N�A=�y�-.,: Yy elf41Vlon� `�r' to ii� ��Prorairi:��S` { �0� -ecatioii:8.�lVlainfenaric S�'�:=`�'��:=��.� ;Sludge'D's a ther:��-''�^�>': Section D. Summary of Findings/Comments: 1. A copy of the NPDES permit was on site at the time of inspection. 2. A compliance evaluation for the period of January, 1999 through December, 1999 revealed no NPDES permit violations. 3. Settleable Solids, pH, Turbidity; and Residual Chlorine are analyzed on site at the Hoffer WTP. Total Suspended Solids, Iron and Aluminum samples are analyzed at the Cross Creek WWTP. Upstream and downstream samples are not taken by the plant operators because of an agreement with the Middle Cape Fear River Basin Association. 4. Laboratory data was reviewed for the month of September, 1999 and October, 1999. All data seemed to be correctly recorded as on the DMR. The only discrepancy that was discoveredis that three collection dates on the laboratory sheets did not match the collection dates on the DMR for September. Ms. Bernice Kidd, Laboratory Supervisor, was notified of the errors and said this problem would be taken care of. 5. Flow rate is measured by a Nomograph pipe reading system. With this type of system, the flow rate is calculated and determined by the height of the water inside of the pipe. Also, maintenance records were reviewed for the past six months. 6. Solids from the sedimentation basins and backwash water from the filtration system are pumped to an equalization basin. Wastewater from the Glenville WTP is also piped into this basin. A polymer is then added and mixed with the wastewater. The wastewater is then pumped into two (2) newly installed clarifiers. The effluent overflows the weirs in these clarifiers and is gravity fed to the outfall point. The ten (10) acre lagoon at this facility is now used as the back up for the clarifiers. Sludge from the clarifiers is transferred to the Cross Creek WWTP by a pipeline. Sludge from the lagoon is land applied and at time of the inspection, the lagoon was being dredged to remove the sludge. 7. The effluent outfall was easily accessible and the effluent was very clear. Name and Signature of Inspector Agency/Office/Telephone Hughie M. White II %i¢ f'/ 1i �/"DENR/Fayetteville/910-486-1541 Belinda S. Henson Name and Signature of Reviewer Agency/Office/Telephone Paul E. Rawls \ / DENR/Fayetteville/910-486-1541 Action Taken Regulatory Office Use Only Compliance Status _Noncompliance _Compliance Date .3-3/-00 3^- Date ci 1�P Date INSPECTION REPORT UPDATE OPTION: TRX: 5IF KEY: NC0076783INSCEI 000328 - SYSMSG: *** DATA ADDED SUCCESSFULLY *** PERMIT--- NC0076783 REG/COUNTY-- 06 CUMBERLAND FACILITY-- PWC/FAYETTEVILLE - HOFFER WTP LOC-- FAYETTEVILLE INS TYPE CEI NEXT PLANNED INSPECTION INSPECTED BY: DATE: 000328 WMH REPORT INSPECTION DMR RESPONSE RECEIVED DATE STATUS STATUS DUE DATE DATE 000331 C C COMMENTS: