Loading...
HomeMy WebLinkAboutWQ0033275_Application (FTSE)_20210317JAMESTOWN ENGINEERING GROUP, INC. ` CIVIL ENGINEERS &SURVEYORS LAND PLANNING •MUNICIPAL CONSULTING Cinc. 117 East Main Street • P.O. Box 365 • Jamestown, N.C. 27282 Telephone (336) 886-5523 Fax (336) 886.5478 www.jamestownengineering.com NC Department of Environmental Quality Received MAR 17 2021 Winston-Salem Regional Office March 10, 2021 Re: Royal Pines Subdivision (AKA Diamonds Keep Subdivision) City of Archdale, NC Randolph County Sewer Permit Modification Request Permit No. WQ0033275 JEG Job #19027 Division of Water Resources NC DEQ — Winston-Salem Regional Office 450 W. Hanes Mill Road Winston-Salem, NC 27105 Dear Sirs/Madams: With regards to the referenced site and on behalf of the City of Archdale, we are requesting a modification of existing Permit No. WQ 0033275 issued on August 7, 2008. Due to a reduction in the project scope, infrastructure modifications will reduce the length of permitted sewer lines, and reduce the number of lots and subsequent waste flows generated at the site. The reductions are summarized as follows: Original Proposed Total Permit Modification Reduction 8-inch Sewer Line 12,323 LF 10,924 LF 1,399 LF Waste Flow (@ 360 GPD/lot) 73,800 GPD 68,760 GPD 5,040 GPD (205lots) (191lots) In addition, the name of the subdivision has been changed from Diamonds Keep Subdivision to Royal Pines Subdivision. On this basis, we have enclosed the following documents in support of the Permit modification: • One original & one copy of the Fast Tract Sewer Application (FTA 04-16) • $480 Application fee • 8.5" X 11" Color USGS topographic map Division of Water Resources March 10, 2021 Page -2- If there are any questions or additional information required in support of this Permit modification request, please call. Yours very truly, JAMESTOWN ENGINEERING GROUP, INC. l / G Daniel W. Pritchett, PE & PLS DWP/cp Enclosures Cc: Mr. Zeb Holden, City Manager Mr. Scott Wallace, Keystone Group, Inc. QW ; R `Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: City of Archdale (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ® Municipal ❑ Other 3. Signature authority's name: Zeb Holden per 15A NCAC 02T .0106(b) Title: City Manager EnNC vironmental Department of quality 4. Applicant's mailing address: PO Box 14068 ReceiVed City: Archdale State: NC Zip: 27263- MAR 17 2021 5. Applicant's contact information: Winston-Salem Phone number: (336) 434-7346 Email Address: zholdenng achdale-nc.gov Regional Office II. PROJECT INFORMATION: 1. Project name: Royal Pines Subdivision (AKA Diamond's Keep 2. Application/Project status: ❑ Proposed (New Permit) ® Existing Permit/Project If a modification, provide the existing permit number: WQ0033275 and issued date: August 7, 2008 If new construction but part of a master plan, provide the existing permit number: W000 3. County where project is located: Randolph County 4. Approximate Coordinates (Decimal Degrees): Latitude: 35860 Longitude:-79_93° 5. Parcel ID (if applicable): 7726496982 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Daniel W. Pritchett, PE License Number: 11659 Firm: Jamestown Engineering Group, Inc Mailing address: 117 E. Main Street, P.O. Box 365 City: Jamestown State: NC Zip: 27282-_ Phone number: (336) 886-5523 Email Address: dangiamestownengineering com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: High Point Eastside Treatment Plant Permit Number: NC 0024210 Owner Name: City fHigh Point V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. PermitNumber(s): WQ_ System Wide Collection System Permit Number(s) (if applicable): WQCS Owner Name(s): _ FORM: FTA 04-16 Page I of 5 VL GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑No ®N/A 3. If the Applicant is a Home/Prol2eity Owners' Association, has an Operational Agreement (FORM: HOA) been attached? ❑ Yes ❑No ®N/A 4. Origin of wastewater: (check all that apply): ® Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100 % Domestic/Commercial % Commercial _ % Industrial (See 15A NCAC 02T .0103(20)) "Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Hasa flow reduction been approved under 15A NCAC 02T .0114(f)? ❑ Yes ®No ➢ If yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(fl) Daily Design Flow " b No. of Units Flow Residential House (3 bedrooms) 360 gal/day 191 68,760 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 68,760 GPD a See 15A NCAC 02T .0114(b), (d), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 68760 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: ETA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8" 10,389 PVC 8" 535 DI ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 1 2. Approximate Coordinates (Decimal Degrees): Latitude: 35.857° Longitude:-79.928' 3. Design flow of the pump station: 0.374 millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): 260 gallons per minute at 49 feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6" 3,455 PVC 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ® Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B): ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): I. Does the project comply with all separations found in 15A NCAC 02T .0305(f) & (g) ® Yes ❑ No ➢ 15A NCAC 02T.0305( contains minimum separations that shall be provided for sewers stems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines horizontal - reclaimed over sewer 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class Il impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage ➢ If noncompliance with 02T.0305(f) or (a), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes [-]No ➢ Seethe Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with all setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No ➢ This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project comply with an individual 404 Permit or any 401 Certifications? ® Yes ❑ No ➢ Wetland -related permits shall be requested, obtained, and adhered to for projects that impact wetlands or surface waters ➢ Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes [:]No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: I. Does the submitted system comply with I SA NCAC 02T, the Minimum Design Criteria for the Permitting of Puma Stations and Force Mains (latest version) and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? 0 Yes ❑ No If No, complete and submit the Variance/Allemative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: name from Application Item 111.1.) that this application for has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications. engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215,6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T .0106(b): rru WIA,v/4Ccl�' _ attest that this application for & thlb from Application Item 1.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties. injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: LZ2� Dater FORM: FTA 04.16 Page 5 ol'5 jz PLL r"LENCVLA,R r.. , it �Q ARRPR £JB i z a IS t f 'may , �f — ,o ntwikla5,rnn w dt ��' �� i�ali r 1, .'i -' z hvbE RE Ct4 u, 't.r} i ..; 1� J j � 1 J, ... � ✓ r�r i MARLBRCJPr�' 'i _ p AL ➢ Q It r A.L� y, L _ nc �I�;sEE 41 m v i I lb�°ii I NORTH CAROLINA