Loading...
HomeMy WebLinkAbout20201650 Ver 1_ePCN Application_20210314DWR Division of Water Resources Pre -Construction Notification (PCN) Form October 26, 2020 Ver 3.3 Initial Review Has this project met the requirements for acceptance in to the review process?* r Yes r No Is this project a public transportation project?* C Yes r No Change only if needed. BIMS # Assigned 20201650 Is a payment required for this project?* r No payment required r Fee received r Fee needed - send electronic notification Reviewing Office * Central Office - (919) 707-9000 Information for Initial Review 1a. Name of project: Snow Hill Road Force Main 1a. Who is the Primary Contact?* Keven Arrance 1b. Primary Contact Email:* karrance@hazenandsawyer.com Date Submitted 3/14/2021 Nearest Body of Water Eno River Basin Neuse Water Classification WS-N; NSW Site Coordinates Latitude: Longitude: 36.076391-78.869788 Pre -Filing Meeting Information ID# 20201650 Pre -fling Meeting or Request Date* 11/2/2020 Attach documentation of Pre -Filing Meeting Request here:* DWR Pre -Filing Meeting Request Form.pdf Version#* 1 What amout is owed?* r $240.00 r $570.00 Select Project Reviewer* Rick Trone:eads\rvtrone 1c. Primary Contact Phone:* (919)522-4269 Version 1 51.39KB A. Processing Information C^U County (or Counties) where the project is located: Durham Is this a NCDMS Project r Yes r No Is this project a public transportation project?* r Yes r No la. Type(s) of approval sought from the Corps: W Section 404 Permit (wetlands, streams and waters, Clean Water Act) r Section 10 Permit (navigable waters, tidal waters, Rivers and Harbors Act) Has this PCN previously been submitted?* r Yes r No 1b. What type(s) of permit(s) do you wish to seek authorization? W Nationwide Permit (NWP) r Regional General Permit (RGP) r Standard (IP) 1c. Has the NWP or GP number been verified by the Corps? r Yes r No Nationwide Permit (NWP) Number: NWP Numbers (for multiple NWPS): NWP 58 1d. Type(s) of approval sought from the DWR: W 401 Water Quality Certification - Regular r Non-404 Jurisdictional General Permit r Individual Permit le. Is this notification solely for the record because written approval is not required? For the record only for DWR401 Certification: For the record only for Corps Permit: r 401 Water Quality Certification - E)press V Riparian Buffer Authorization 1f. Is this an after -the -fact permit application?* r Yes r No 1g. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts? r Yes r No 1g. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts? r Yes r No Acceptance Letter Attachment Buffer SOA - Snow Hill Road Force Main.pdf 1h. Is the project located in any of NC's twenty coastal counties? r Yes r No 1j. Is the project located in a designated trout watershed? r Yes r No B. Applicant Information 1d. Who is applying for the permit? r Owner W Applicant (other than owner) le. Is there an Agent/Consultant for this project?* r Yes r No 2. Owner Information 2a. Name(s) on recorded deed: City of Durham 2b. Deed book and page no.: utility easement 2c. Responsible party: Donald Greeley 2d.Address 119.63KB * r Yes r No r Yes r No Street Address 1600 Mist Lake Drive Address tine 2 city Durham Postal / Zip Code 27704 2e. Telephone Number: (919)560-4381 2g. Email Address:* Donald. F.Greeley@durhamnc.gov 3. Applicant Information (if different from owner) 3a. Name: Vincent Chirichella, Jr., P.E., Sr. Project Manager 3b. Business Name: Durham County 3c.Address Street Address 5926 Highway 55 East Address tine 2 city Durham Postal / Zip Code 27713 3d. Telephone Number: (919)560-9039 3f. Email Address:* vchiricheIla@dconc.gov 4. Agent/Consultant (if applicable) 4a. Name: Keven Arrance 4b. Business Name: Hazen and Sawyer 4c.Address Street Address 4011 WestChase Boulevard, Suite 500 Address Line 2 City Raleigh Postal / Zip Code 27607 4d. Telephone Number: (919)522-4269 0. Email Address:* karrance@hazenandsawyer.com Agent Authorization Letter* Agent Auth signed_ VChirichella202l.pdf C. Project Information and Prior Project History 1. Project Information 1b. Subdivision name: (i appropriate) 1c. Nearest municipality/ town: Durham 2. Project Identification State / Rovince / Rion NC Country USA 2f. Fax Number: Slate / Rwince / Region NC Country USA 3e. Fax Number: State / Rmime / Region NC Country USA 4e. Fax Number: 43.33KB 2a. Property Identification Number: n/a 2b. Property size: 12.3 2c. Project Address Street Address begins at 2525 Snow Hill Road Address Line 2 City Durham Postal / Zip Code 27712 3. Surface Waters 3a. Name of the nearest body of water to proposed project:* Eno River 3b. Water Resources Classification of nearest receiving water:* WS-N; NSW 3c. What river basin(s) is your project located in?* Neuse 3d. Please provide the 12-digit HUC in which the project is located. 030202010304 4. Project Description and History State / Province / Region NC Country USA 4a. Describe the existing conditions on the site and the general land use in the vicinity of the project at the time of this application:* The project generally follows maintained roadway rights -of -way and maintained utility easements. The corridor is abutted by undeveloped forested areas, rural residential properties, an institution, agricultural lands, and an active quarry. The proposed project connects to an existing pump station at the downstream end and to a pump station that is currently under construction at the upstream end. 4b. Have Corps permits or DWR certifications been obtained for this project (including all prior phases) in the past?* r Yes r No r Unknown 4d. Attach an 8 1/2 X 11 excerpt from the most recent version of the USGS topographic map indicating the location of the project site. (for DWR) PCN SHRFM_topo.pdf 396.72KB 4e. Attach an 8 1/2 X 11 excerpt from the most recent version of the published County NRCS Soil Survey map depicting the project site. (for DWR) Detailed Soil Map; Soil Survey of Durham County, North Carolina - map13_2.pdf 689.55KB Detailed Soil Map; Soil Survey of Durham County, North Carolina - map14_2.pdf 690.4KB 4f. List the total estimated acreage of all existing wetlands on the property: 0.40 4g. List the total estimated linear feet of all existing streams on the property: 3375 4h. Explain the purpose of the proposed project:* The existing force main is a 12-inch diameter pipe that conveys wastewater from the existing Snow Hill Road Pump Station to a 21-inch diameter gravity sewer, which carries the wastewater to the Eno River Pump Station. The Snow Hill Road Pump Station is being replaced under a separate project (SAW-2020-00987 and DWR #20-0727), and the existing 12- inch force main does not have the capacity to hydraulically accommodate future peak flow rates from the new Snow Hill Road Pump Station. The proposed 20-inch Snow Hill Road Force Main will convey flows to a proposed new segment of gravity sewer at the Eno River Pump Station. The new segment of gravity sewer will replace the downstream most segment of the existing, 21-inch influent sewer and will tie into the existing 48-inch influent gravity sewer. 41. Describe the overall project in detail, including indirect impacts and the type of equipment to be used:* The project consists of installation of approximately 14,423 feet of 20-inch sewer force main and 120 feet of 48-inch gravity sewer. The force main and gravity sewer will be ductile iron pipe. The force main pipe will extend from an existing fitting in the sewer collection network located at 2525 Snow Hill Road to a new manhole (MH-1) adjacent to the Eno River Pump Station. The proposed force main will parallel the existing force main, which will be abandoned once the proposed pipe is put into service. The pipe corridor parallels the west side of the right-of-way associated with Snow Hill Road, heading south to just southeast of the eastern terminus of Infinity Road. The pipe corridor then turns to the southwest, following the existing utility easement toward the Eno River. The proposed pipe will cross the Eno River, traverse an undeveloped island, and cross an oxbowconnected to the Eno River. The river, island, and oxbow crossings Will be installed via a trenchless technique, specifically horizontal directional drilling. The pipe corridor follows the existing sewer easement to the west, then north- northwest, then west to MH-1 adjacent to the Eno River Pump Station. The gravity sewer will begin at manhole MH-1 and extend to an existing manhole (MH-4) that is proposed to be replaced. From MH-4, the existing gravity sewer Will convey the wastewater into the Eno River Pump Station. From MH-1 to the end of the existing 21-inch diameter gravity sewer, the existing gravity line will be removed. The proposed 48-inch gravity sewer, extending from MH-1 to MH-4, Will provide conveyance of flows currently carried by the gravity sewer segment to be demolished. To accomplish the connections and turns required along the 48-inch gravity line, a total of four manholes Will be installed. The pipe will be installed via open cut trench for the majority of its length. The crossing of Infinity Road Will be installed by jack and bore. Horizontal directional drilling will be the method of installation under the Eno River and an oxbow of the Eno River. The pipe Will also be horizontally directionally drilled across the island located between the Eno River and its oxbow. The proposed sewer pipe crosses eight streams, including Cabin Branch, the Eno River, the Eno River oxbow, an unnamed tributary (UT) to the Eno River, two UTs to Little River, and two UTs to Cabin Branch. Temporary impacts to six of the streams are proposed to result from the open -cut installation of the new force main. The stream crossings will be performed under dry conditions, using a cofferdam and temporary pump -around system to establish and maintain the dry work area. Once the streambed and banks are restored to their pre - construction grade and elevation and stabilized, the temporary pump -around system and cofferdams will be removed, allowing the stream flowto return to its natural course. The pipe corridor is in proximity to two jurisdictional wetland areas and one pond. The wetlands and the pond Will not be impacted by construction of the proposed project. A variety of construction equipment is anticipated to be used due to the various construction techniques for the project. A horizontal directional drill rig and associated equipment, reamers, HOPE pipe rollers, cranes, jack and bore machine, backhoes, trackhoes, excavators, shoring equipment, land clearing equipment, and welders are expected to be used. Additionally, grout pumps, temporary stream bypass pumps, generators, and dump trucks are expected to be utilized. Other construction equipment may be utilized at the discretion of the contractor. 4j. Please upload project drawings for the proposed project. 31453-000 - Forcemain.pdf 5. Jurisdictional Determinations 5a. Have the wetlands or streams been delineated on the property or proposed impact areas?* r Yes r No Comments: 5b. If the Corps made a jurisdictional determination, what type of determination was made?* r Preliminary r Approved r Not Verified f^ Unknown r N/A Corps AID Number: 5c. If 5a is yes, who delineated the jurisdictional areas? Name (if known): K. Arrance, L. Diebolt Agency/Consultant Company: Hazen and Sawyer Other: 5d1. Jurisdictional determination upload 6. Future Project Plans 10.68MB r Unknown 6a. Is this a phased project?* r Yes r No Are any other NWP(s), regional general permit(s), or individual permits(s) used, or intended to be used, to authorize any part of the proposed project or related activity? No. D. Proposed Impacts Inventory 1. Impacts Summary 1a. Where are the impacts associated with your project? (check all that apply): r Wetlands W Streams -tributaries W Buffers r Open Waters r Pond Construction 3. Stream Impacts 3a. Reason for impact (?) 3b.lmpact type * 3c. Type of impact* 3d. S. name* 3e. Stream Type* Type of 3gSwidth * 3h. Impact(?) ❑ �[3f. urisdiction* length* 81 Pipe installation Temporary Excavation Fb�nBranch Perennial Corps 20 30 Average (feet) (linearfeet) g2 Pipe installation Temporary Excavation UT1 to Cabin Branch Intermittent Corps 6 98 Average (feet) (lirearfeet) S3 Pipe installation Temporary Excavation UT2 to Cabin Branch Intermittent Corps 3 51 Average (feet) (linearfeet) S4 Pipe installation P Tem orar P Y Excavation UT1 to Little River Intermittent Cor P s 5 30 Average (feet) (lirearfeet) S5 Pipe installation Temporary Excavation UT2 to Little River Intermittent Corps 7 37 Average (feet) (linearfeet) H Pipe installation Temporary Excavation UT1 to Eno River Intermittent Corps 6 30 Average (feet) (linearfee[) 31. Total jurisdictional ditch impact in square feet: 0 31. Total permanent stream impacts: 0 31. Total stream and ditch impacts: 276 3j. Comments: 31. Total temporary stream impacts: 276 6. Buffer Impacts (for DWR) 6a. Project is in which protect basin(s)? Check all that apply. V Neuse F Catawba F Goose Creek r Other r Tar -Pamlico r Randleman r Jordan Lake 6b. Impact Type 11 6c. Per or Temp 6d. Stream name 6e. Buffer mitigation required? 6f. Zone 1 impact 6g. Zone 2 impact B1 - deemed allowable P Cabin Branch No 2,787 759 B2 - allowable with mitigation P LF1 to Cabin Branch Yes 4,823 0 B3 - allowable with mitigation T LF1 to Cabin Branch No 2,153 0 64 - deemed allowable T LF1 to Cabin Branch No 0 1,174 B5 - deemed allowable P LF1 to Cabin Branch No 0 581 66 - deemed allowable P LIT2 to Cabin Branch No 0 852 67 - deemed allowable T LIT2 to Cabin Branch No 0 483 B8 - allowable with mitigation P LIT2 to Cabin Branch Yes 380 0 B9 - allowable with mitigation T LIT2 to Cabin Branch No 2,508 0 B10 - deemed allowable P tJT1 to Little River No 1,893 1,511 1311 -deemed allowable T tJT1 to Little River No 523 498 B12 - deemed allowable T LIT2 to Little River No 0 815 B13 - deemed allowable P LIT2 to Little River No 2,278 860 B14 - deemed allowable T tJT2 to Eno River No 1,825 1,216 6h. Total buffer impacts: Zone 1 Zone 2 Total Temporary impacts: 7,009.00 4,186.00 Zone 1 Zone 2 Total Permanent impacts: 12,161.00 4,563.00 Zone 1 Zone 2 Total combined buffer impacts: 19,170.00 8,749.00 6i. Comments: Supporting Documentation PCN SHRFM_impacts_WOTUS_all.pdf PCN SHRFM_impacts _Buffers _all.pdf E. Impact Justification and Mitigation 1. Avoidance and Minimization 2.5MB 2.49MB 1a. Specifically describe measures taken to avoid or minimize the proposed impacts in designing the project: u Impacts to jurisdictional areas can only be fully avoided by a no -build alternative, which does not meet the purpose and need for the project. Extensive efforts to minimize impacts to jurisdictional areas have been made during the development of the project design. The proposed force main follows an existing force main parallel to an existing NCDOT road and in both existing and proposed easement. Designing the pipe along an already maintained corridor minimizes new impacts to streams as they are already being maintained. In locations where new easement is required due to space limitations inside the existing easement, the new force main is designed to be installed as close to the existing easement as possible in order to minimize the new easement width. Wetland and open water impacts have been fully avoided by modifications to the alignment and the width of disturbance in areas near these features. The limits of disturbance have been reduced in width within streams and riparian buffer areas. Permanently maintained corridors will be retained in perpetuity to accommodate future operations and maintenance needs and provide access for emergency response. Where feasible, the maintained corridor for the proposed force main will coincide with currently maintained corridors. The proposed new maintained corridors have been reduced in width within stream buffer areas. The maintained corridors will be seeded with native grasses. The portions of the construction corridor that are beyond the maintained corridor will be allowed to revegetate naturally from local seed stock. Relocating the pipe to the east side of Snow Hill Road may offer an opportunity to further reduce the impacts to UT1 to Cabin Branch. However, this alignment modification was eliminated from consideration due to the presence of an existing natural gas pipeline parallel to the east side of Snow Hill Road in this area. The measures necessary to avoid conflicts with the natural gas pipeline would result in significantly greater private property impacts, tree removals, and risks during construction. Crossings of streams and riparian buffer areas have been designed to be within 15 degrees of perpendicular to the extent practicable. One stream crossing (S3 — UT2 to Cabin Branch) is not practicable to be achieved at a near -perpendicular angle. Crossing Lfr2 to Cabin Branch at a near - perpendicular angle would necessitate disturbance of approximately 3,275 square feet of forested buffer that will not be disturbed as a result of the proposed design. The design keeps the buffer disturbance almost entirely in areas that are currently maintained as part of the roadway right-of-way, overhead electric easement, and buried utility easement. The impacts to the buffer associated with the UT2 to Cabin Branch crossing will consist of temporary disturbance of maintained grassy areas that will be restored to pre -construction conditions upon installation of the force main. 1b. Specifically describe measures taken to avoid or minimize the proposed impacts through construction techniques: The erosion and sediment control measures specified in the design will be installed prior to initiation of land disturbance. Regular inspections of the erosion and sediment control devices Will be performed, and any necessary repairs or modifications to the devices will be addressed in a timely manner to ensure that they are maintained in good working order throughout the construction period. Erosion and sediment control devices shall include silt fencing, fiber filtration tubes and channel lining for drainage swales and roadside ditches, stabilized construction entrances, and temporary stabilization of disturbed soils and sediments. Excavations will be backfilled and restored on a daily basis to protect against erosion of disturbed soils. Installation methods were evaluated for each stream crossing associated with the proposed design. Where practicable, trenchless techniques wall be utilized to avoid impacts to streams and buffers. Horizontal directional drilling Will be performed for the Eno River and Eno River oxbow installation. Trenchless techniques were determined to be infeasible options at the remaining six stream and buffer crossings. In -stream construction Will be performed in the dry. Temporary cofferdams and pump -around system will be utilized to establish and maintain dry conditions within the work area. Stream water discharged from the pump will pass through a filter bag or other device intended to remove excess sediments from the water prior to returning to the stream channel downstream of the work area. Construction support activities Will be performed away from surface waters, riparian buffers, and other sensitive resources. Vehicle and equipment maintenance Will be performed in upland areas to protect against unintentional spills or leaks reaching sensitive ecological areas. Staging of equipment and materials will be sited in upland areas along the project construction corridor. 2. Compensatory Mitigation for Impacts to Waters of the U.S. or Waters of the State 2a. Does the project require Compensatory Mitigation for impacts to Waters of the U.S. or Waters of the State? r Yes r No 2b. If this project DOES NOT require Compensatory Mitigation, explain why: Impacts to waters of the US are temporary and do not require compensatory mitigation. F. Stormwater Management and Diffuse Flow Plan (required by DWR) 1. Diffuse Flow Plan 1a. Does the project include or is it adjacent to protected riparian buffers identified within one of the NC Riparian Buffer Protection Rules? r Yes r No What type of SCM are you providing? r Level Spreader r Vegetated Conveyance (lower SHWT) r Wetland Swale (higher SHWT) r Other SCM that removes minimum 30 % nitrogen W Proposed project will not create concentrated stormv✓ater flow through the buffer Diffuse Flow Documentation PCN Diffuse Flow SHRFM.pdf 2. Stormwater Management Plan 2a. Is this a NCDOT project subject to compliance with NCDOT's Individual NPDES permit NCS000250?* r Yes r No 2b. Does this project meet the requirements for low density projects as defined in 15A NCAC 02H .1003(2)? r Yes r No Comments: G. Supplementary Information 44.64KB u 1. Environmental Documentation 1a. Does the project involve an expenditure of public (federal/state/local) funds or the use of public (federal/state) land?* r Yes r No 1b. If you answered "yes" to the above, does the project require preparation of an environmental document pursuant to the requirements of the National or State (North Carolina) Environmental Policy Act (NEPA/SEPA)?* r Yes r No Comments: Project does not meet the minimum requirements that trigger a NEPA or SEPA review. 2. Violations (DWR Requirement) 2a. Is the site in violation of DWR Water Quality Certification Rules (15A NCAC 2H .0500), Isolated Wetland Rules (15A NCAC 2H .1300), or DWR Surface Water or Wetland Standards or Riparian Buffer Rules (15A NCAC 2B .0200)? * r Yes r No 3. Cumulative Impacts (DWR Requirement) 3a. Will this project result in additional development, which could impact nearby downstream water quality?* r Yes r No 3b. If you answered "no," provide a short narrative description. The project will not induce additional development. The project eliminates an existing capacity reduction in a downstream segment of the existing sewer collection system, allowing the downstream segment to convey the same capacity as the upstream segments that feed into it. 4. Sewage Disposal (DWR Requirement) 4a. Is sewage disposal required by DWR for this project?* r Yes r Nor WA 5. Endangered Species and Designated Critical Habitat (Corps Requirement) 5a. Will this project occur in or near an area with federally protected species or habitat?* r Yes r No 5b. Have you checked with the USFWS concerning Endangered Species Act impacts?* r Yes r No 5d. Is another Federal agency involved?* r Yes r No r Unknown 5e. Is this a DOT project located within Division's 1-8? r Yes r No 5f. Will you cut any trees in order to conduct the work in waters of the U.S.? r Yes r No 5g. Does this project involve bridge maintenance or removal? r Yes r No 5h. Does this project involve the construction/installation of a wind turbine(s)?* r Yes r No 5i. Does this project involve (1) blasting, and/or (2) other percussive activities that will be conducted by machines, such as jackhammers, mechanized pile drivers, etc.? r Yes r No If yes, please provide details to include type of percussive activity, purpose, duration, and specific location of this activity on the property. SHRFM - blasting description.pdf 76.01 KB 5j. What data sources did you use to determine whether your site would impact Endangered Species or Designated Critical Habitat? The IPaC tool was utilized to identify the federally protected species that may occur in the project vicinity. IPaC identified three species proposed for listing, three endangered species, and two proposed critical habitat areas. The endangered species include dwarf wedgemussel (DWM), Michaux's sumac, and smooth coneflower. DWM's inclusion on the list is associated with the Eno River. The Eno River and its oxbow will be traversed via trenchless technique, thereby avoiding impacts to the waterways, their habitats, and water quality in the waterways. Michaux(s sumac and smooth coneflower inhabit disturbed areas and edges of forested areas that occur on circumneutral to basic soils. The soils required for the endangered plants are not mapped within the project area. Hazen biologists performed visual assessments of the project area during onsite investigations in June 2020 and observed no individuals of the two species. Designated critical habitat has been proposed for two species that are proposed for listing - Carolina madtom and %use River waterdog. The proposed critical habitat for Carolina madtom and for Meuse River waterdog within the project area is within the Eno River, which will be crossed by a trenchless technique and thereby not impacted by the proposed project. Consultation Documentation Upload IPaC_20210119.pdf 392.02KB 6. Essential Fish Habitat (Corps Requirement) 6a. Will this project occur in or near an area designated as an Essential Fish Habitat?* r Yes R No 6b. What data sources did you use to determine whether your site would impact an Essential Fish Habitat?* Review of online interactive EFH mapper via NOAA website. 7. Historic or Prehistoric Cultural Resources (Corps Requirement) 7a. Will this project occur in or near an area that the state, federal or tribal governments have designated as having historic or cultural preservation status?* r Yes r No 7b. What data sources did you use to determine whether your site would impact historic or archeological resources?* HPOWEB was reviewed most recently on January 19, 2021. Two properties are identified as having a structure that has been surveyed only. The project involves temporary excavation for installation of a sewer line adjacent to an existing buried sewer line. Any archaeological resources that may remain within the proposed excavation footprint will be returned to the trench as backfill. 7c. Historic or Prehistoric Information Upload HPOWEB_20210119.pdf 297.31 KB 8. Flood Zone Designation (Corps Requirement) 8a. Will this project occur in a FEMA-designated 100-year floodplain?* r Yes r No 8b. If yes, explain how project meets FEMA requirements: The project design minimizes disturbance within the 100-year floodplain to the minimum necessary to accomplish the pipeline installation. Design elements have been included in the erosion and sediment control plan to prevent off -site erosion and to mitigate it when unavoidable. A floodplain development permit will be obtained from the City of Durham prior to initiation of construction. 8c. What source(s) did you use to make the floodplain determination?* FEMA FIRMS 3720083500K, 3720084400K, and 3720083400K; all effective 10/19/2018 Miscellaneous C^U Comments Miscellaneous attachments not previously requested. Snow Hill Rd Force Main Buffer Determination Letter.pdf 1.67MB PCN SHRFM_aerial vicinity.pdf 620.81 KB Signature W By checking the box and signing below, I certify that: • The project proponent hereby certifies that all information contained herein is true, accurate, and complete to the best of my knowledge and belief; and • The project proponent hereby requests that the certifying authority review and take action on this CWA 401 certification request within the applicable reasonable period of time. • I have given true, accurate, and complete information on this form; • I agree that submission of this PCN form is a "transaction" subject to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act"); • I agree to conduct this transaction by electronic means pursuant to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act'); • I understand that an electronic signature has the same legal effect and can be enforced in the same way as a written signature; AND • I intend to electronically sign and submit the PCN form. Full Name: Keven Arrance Signature Date 3/14/2021 u     EBX Buffer Mitigation Banks Statement of Availability January 21, 2021 NC Division of Water Resources Stephanie Goss 512 N. Salisbury St. Archdale Building, 9th floor Raleigh, NC 27604 Re Project: Snow Hill Road Force Main This document confirms that Durham County (Applicant) for the Snow Hill Road Force Main (Project) has expressed an interest to utilize 15,609.00 Square Feet of Riparian Buffer Mitigation Credits from the EBX sponsored Upper Neuse Riparian Buffer Umbrella Mitigation Bank or EBX-Neuse I, LLC sponsored Bucher Mitigation Bank. The specific bank site to be debited will either be Cedar Grove, Hatley or Bucher all located in HUC 03020201 and in the Falls Lake watershed. As the official Bank Sponsor, EBX and EBX-Neuse I, LLC, attests to the fact that mitigation is available for reservation at this time. These mitigation credits are not considered secured, and consequently are eligible to be used for alternate purposes by the Bank Sponsor, until payment in full is received from the Applicant resulting in the issuance of a Mitigation Credit Transfer Certificate by the bank acknowledging that the Applicant has fully secured credits from the bank and the Banker has accepted full responsibility for the mitigation obligation requiring the credits/units. The Banker will issue the Mitigation Credit Transfer Certificate within three (3) days of receipt of the purchase price. Banker shall provide to Applicant a copy of the Mitigation Credit Transfer Certificate and a documented copy of the debit of credits from the Bank Official Credit Ledger(s), indicating the permit number and the resource type secured by the applicant. A copy of the Mitigation Credit Transfer Certificate, with an updated Official Credit Ledger will also be sent to regulatory agencies showing the proper documentation. Please contact me at 919-209-1075 or cparker@res.us if you have any questions or need additional information. Best Regards, Caitlan B. Parker Resource Environmental Solutions, LLC 701 E. Bay Street, Suite 306 Charleston, SC 29403 Bank Sponsors – Environmental Banc & Exchange (EBX) and EBX-Neuse I, LLC AGENT AUTHORIZATION LETTER PROJECT LOCATION: The project consists of approximately 14,500 feet of proposed sewer force main. The corridor is located in Durham, along Snow Hill Road and paralleling an existing sewer easement. The corridor consists of the permanent utility easement associated with the proposed Snow Hill Road Force Main. STREET ADDRESS: Northern terminus is located at 2405 Snow Hill Road, Durham, NC. _ Southern terminus is located behind the Hanson Aggregates sales yard at 5013 Denfield St, Durham, NC. Please print: Applicant: City of Durham, Water Management Applicant Contact Person: Vincent Chirichella, P.E., Sr. Project Manager The undersigned applicant of the proposed project do hereby authorize Keven Arrance (Consultant / Agent) of Hazen and Sawyer (Name of Consulting Firm) to act on my behalf and take all actions necessary for the processing, issuance and acceptance of the attached permit or certification and any and all standard and special conditions attached. Applicant's Mailing Address (if different than property above): 5926 Highway 55 East, Durham, NC 27713 Telephone: 919.560.9039 We hereby certify the above information submitted in this application is true and accurate to the best of our knowledge. I S'�e. �iZo�Ccf M+��lg4Ett 3 Z° 2�Z/ (Applicant) (Date) Eno RiverPump Station Snow Hill RoadPump Station Proposed Force Main AlignmentTrenchless Installation Technique Proposed Force Main AlignmentOpen Cut Installation Proposed Force Main AlignmentOpen Cut Installation Figure 1: Topographic MapSnow Hill Road Force MainDurham CountyDurham, North Carolina®1 inch = 2,000 feet 0 1,000 2,000500Feet Legend Force Main Alignment Limits of Disturbance Stream Wetlands Pond DURHAM COUNTY, NORTH CAROLINA — SHEET NUMBER 13 Ge6 2020000FEET _ Wn MfB AI9 (Joins sheet 10) _ 13 / 11rC Hr8 MtC '4 \� 3 `� j -, ti = s.v tB +� f - AIB GeB °p v NrC l a - 11r. Hrc HrB a� MfD " z,� C`' - q6t)� �gB HrB \ HrC F{.8 GeB -�' I ��.• `rflI 1 MfC N MfC CrB GfF r'S '\O Ch - Ro '�� �• � n HrC -� MTC HrC \ _ Ch r _ _ G0� ti .-_♦ - Hr6 _x l Qj ? C MfC Cr•B GeC GeB Non ` l ,�� / !C by Vf M `. r = 1' HUr` Hr6 �._ M TC - '`a. ' •i `` tL ,` W MfC MfC m HrB ,Y = 1 �ySB. Ire - MIS Wr t o ,.1NrC M!C . 'y ? 0 r IrC�� CrR MTD 4 GeD J B HrS / ,/ / F' MfC 0 G' f Lo 1 _ _ Mf8 _ _ C GeC _ i_ / {!.- Hr8 r' ti+8 1 - MTB �1 .�; J~ MIS J r` / MtB / T� Hr8 ' CiZ _J !I- rya N� ,� Mf Muc D D ! I n �1. v HrC �' NaDa Ro -f ¢ Ir8 A GeC � MfC ) �1 HrC q; t >tbs _� WsE Cs 1 r53 �l 1 I ' W r - HrCcl ec Mf6 -� i G _ - _ Irc HrC H � ! MfC a) Lg0 G t L {t 0 0 0 t I) G G IrC MIS 40 r GeB CrB I 0 0 �I %a_ - �T j WSE Hrft H:C Q MuB Hea �0 0 0 �1 IrC i jj fr6 M aO �^ 0 / MfC 1 v �01u (I 0 IrB I 0 Ire G r MSB Q. M B t l ,'Ire U IrB Mf6 ' fr6 �-� '� - m'I' p 0 � WXE ; II rr p Mfc ii vp Ch Ch }- 1 G p 0 1rC p •' Et •Ir8 `sZ 3 _ MuC �' "Ir6 0 Ro AfA Ir6 Na, C 0 �- z "'•' -- ! HrC Wh �l j cP �, Ch ' W-E o 4 0 '..� sO - Hr6 Y Cp CJ y HrC eO } f P rK _1. l Ch Hr8 GeB AlB cp 1 GeC - h N 'fit Ter +w- o ri r- O ' _ Au6 _ - v r { Mf Ch - O ' { - � +s.� HrC u. u'� � - Wn AIA .i' ,.. Mu j f J FQ Y I NaD M(f3 p �+ Gm' GeC ► + Mf6 7aE ,Y ' C 0 } 6 .* I ,i _ - . Wh AIA A/% A J r \ MfE / , $! Ir 1 / O l T Cf X HrC NrB p* • C AIB l Mfg U GeD Wm M fc LSr - �s _ f� AIB _ [� CG fr6 ` Muc 1_ 0 D IrC P(E Ch Na- / Y %. cp. 0 NdD AIB - f WE _ 11 I1p 5. �� MID r a- El ? - GIF f /•1 X; .I II` - /tea{ei.. W ,� 3 Gp o Mf8 r AIA /6 Ou �'' IrC - "� I :. - p AIB G D G If IQ Ch MfC fB � � � {, fr6 I MfC i MfC <o. Mf8 MfC WE - _ pa 1 Mt6 %' p MfE MfD ..fir P,' GeC We IrC MfD • � y� j � � tMfe W5B Mf6 IrB MfC HeC = j MiFR fl AI6. CrS MfB 5 ur O GIE GeB rC SOS WsC Cr8 J� M Hr6 pj fC - IrC 1 Cn�y� 0 4 fc WSB Ch�! IrB NaA Mf6 W`B I .. YM7D ' I C ' _ HrE3 r MTB Mf8 W5 Mfg R �Fe ;w Ws9 MTD rr)�3 IrC MfC j 4 1 ? _INf$ -Ir8 T t I Mf8 M - Gu lj Ws8 _Ire_ _ - DURHAM COUNTY. NORTH CAROLINA — SHEET NUMBER 14IF X rC 2 055 pp0 FEET Cp crG wsE Cr$ /p 1.4 - - ---!c•ir�s sheer i ' .. — _ - -- - — --- - - - `1 M4C rB prC/_- N PFE / '�5./ ` GK GrC - C _ Wvrl Alb T Min r'L' l 3Cc. Mf6 MtC - 1 R Ch MfB i(I y �f GrB _ ` co ! L IN Ch CP MfE li u VVI ii -�. Grd U - _ /. {,MfC FALLS \ f r fl . RF.SF.R; UIR AIR MfC MfC I '" CrC MfB WsC f . f ` I AIA t\ . f ! MID rim ti� 11 MEC ri I MMtR Gn CtC MtB cpi- O MiB Y.\ GrC T u) < GrC I.I . 4a i-�� Wn G �L Ch PSE Cc 2 1 ., CYB - /:� '' Co i�� l _ \ W `f WsE Ro Cc 1, Gr 1 �(� WsB i''i` =µEi- o�R I:rl� CP CrB 3� /' f ...i ��/� - l ? / _ r cot•+a'rt MtD r 1 / / -' AM Mfc 1 AlA AIA MfA \ MfB WNWMGr6 y y Ch / v j Gp Cp t, Ch a Wcr; �r WsB GP Mf C PD4R w Co 1 - ^ ' \�� AIB -�•'� m f6 _ ,fti y _ ` Ch` i' - Cr ' --"� / +/ 10 AIA + Ch �J;_/ /�ii- 4v I�i '!t' c\ /! '\ AIA a �.� �� \� \\`, ✓_,// ~l WsB % 11 l- C4e, p I- i _ Ea w56 ITT 11 11 i� wsc �'Ea {� Dc' Cp .CA N AIB / , f Ch Q 0 CrC Cp J' !'., Cr8 AIR r Z U r` if I' - `FALLS i 9 irB f ti cp } 4i RESER4'OIR wsB , Wn IrC '• _-.—.�f I �l — tip. A =;i _--- r--- = o AIA 4 �- . y 4. - CrB l%�B if o00 6 F Ch Ro I % 6 // AIR r of c ,c irB \ G wsc It /o n G V C z d AIA ° v p 0 IrB ' Cp 1" WsC 0 et r / o WSB MfB I /� z h FOOD r 'W58,q ilriJ Cr8 U -..ch ` - 0 -:- Wn - WsE _ 1 2 0Mu AIB WsC IrC / - l „ C j Cp VJn } n Q _ 0 Cn �. • HeB ` MfC _ Of O : , Mua - ALB ^ W56 CrB 0 �r . (,r6 I CrC WsB W5B ❑ �? f WsE �- I I W muc IrC ` Wsc _ o Ch Cfa� WsC 1 Ws$ 0 SIG MfB~ CID i, _\ i Oo WxE �..` h CA Ws8 1 ; \„\ L'� n CrC G h'J<<� - CrB WsB C,r,.8 / Ir '`� i Shy WsE _ ` WsB ! '� I� W5E Cp p r. u 0 ii - rr' G� Cr8 1 _ M.0 Ch i" WsC f } Ne$ G I1 n w % _ 11i 1r8 Cr o cof uMfP �' 11 7 ✓ E9 WsC O / M6 f"E - 'I --` i 0 MfB Vf N tic \\1 �:.. WsE IrC AIA / ` We 1% fl }sr WSE \ W5G' 1k • CrB 1 , �I 46/ f^ j Mtc WsE i CrC II iJ ��- GrC II SB It o PfE - GrB Gr$ \\ �� \ CrC t 1 C \ t1 �t� Ch /. MfB \ '- CrC N } = l.F4LI.S v WsB y it CrB R7ff wSB WsC Ws6 \ I yWsC ? 4 ✓ I I RESERVOIR j' 3 Mf0 l _� fIII MfHeB W5B - = n U + o _ tl B 6: J/. " // J r � ! � ` Mts � 3 : � G� � wsc GrB f' wsc Ire MfB fir' - „ n _ wn WsB n f7 GG 11 AIB a , O - MfC '. 1' ' C' He$ MfB / l 3' HeB 00 MfB ' Crc - CrB 0 i I �s Wn IN �r �' wsc 4} it Ro B MfB WsC ✓z IrC w 1\ �� n WsG ` IrC IrC ti i Mua MuC YGu Irk- _ ptF- MiBi., _ y�5 WsC v,.. 1 s� !; CrB .. rB V Mfc He$ a CrB CI Ro GrC AIB Al floc WsB z G`C Gr8 CrB ti'� MfC M[C WsE C� WsB Ch Ch . ✓�. Irc } fJoins sheet l } WE MfC MfD - ~- - wsC Eno RiverPump Station Snow Hill RoadPump Station Figure 2: Vicinity MapSnow Hill Road Force MainDurham CountyDurham, North Carolina®1 inch = 1,500 feet 0 1,5005001,000 Feet Legend Force Main Alignment Limits of Disturbance Stream Wetlands Pond Snow Hill RoadI n f i n i t y R o a d E n o R i v e r Cabin Branch Little River File: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\GENERAL\31453-000 COVER Saved by ENG Save date: 11/2/2020 4:35 PMPLOT DATE: 1/20/2021 9:23 AM BY: AMARCHCITY OF DURHAM NORTH CAROLINA SNOW HILL ROAD FORCE MAIN PROJECT HAZEN CONTRACT NO. 31453-000 JANUARY 2021 HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO. : C-0381 OLD O X F O R D R D LITTLERIVEROLD OXFORD RDENOENO RIVE R INFIN I T Y R DN ROXBORO RDSNOW HILL RDENO RIVERDENFIELD STHEBRON RD LA T T A R D HORTON RD RIVER GOD W I N R D STANLEY RDSNOW HILL PUMP STATION ENO PUMP STATION 90% SUBMITTAL - NOT FOR CONSTRUCTION GRAVEL SOIL SOIL SOI L GRAVEL GRAVEL SOIL GRAVEL GRAVEL 4' W I RE 4' W I R E 4' W I R E GRAVEL SOIL PA T H SOIL PA TH SOIL P AT H SOIL P A T H SOIL PATHSOIL P AT H SOI L P A T H SOIL PA T H SOIL PATH SOIL PATH SOIL PA T H SOIL PATHSOIL PATHSOIL P A T H SO IL P A TH SO I L P A T H SOIL PATH SOIL PATHGRAVE L SOIL P AT H GRAVEL GRAVEL GRAVEL GRAVEL GRAVEL 4' W I RE 4' W I R E 4' W I R E PLOT DATE: 1/20/2021 9:05 AM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\GENERAL\G1 Saved by AMARCH Save date: 1/19/2021 5:12 PMSNOW HILL ROAD FORCEMAIN 31453-000 01 JANUARY 2021B. PORTER IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 WHARTON-SMITH, INC. 5601 77 CENTER DRIVE #120, CHARLOTTE, NORTH CAROLINA 28217 90% SUBMITTAL - NOT FOR CONSTRUCTION N. JOHNSON E. NG G1 KEY MAP AND DRAWING INDEX B. PORTER SNOW HILL RDSNOW HILL RDENO RI V E R ENO RIVER ENO R I V ER ENO RIVE R ENO PUMP STATION SNOW HILL PUMP STATION SNOW HILL RDC1C2C3C4C5C6C7C8C9C10C11C13 C13 C14 C15C20C21C22C2 3 C24 SCALE: 1" = 600' KEY MAP SNOW V A L L E Y R D WA N D E R L U S T L N STANLEY RDENO RIVER DRGENERAL DESCRIPTION G1 NUMBER COVER DRAWING C1 STATION 0+00 TO 7+00 CIVIL C2 STATION 7+00 TO 14+00 INDEX OF DRAWINGS KEY MAP AND DRAWING INDEX C3 STATION 14+00 TO 21+00 C4 STATION 21+00 TO 28+00 C5 STATION 28+00 TO 35+00 C6 STATION 35+00 TO 42+00 C7 STATION 42+00 TO 49+00 C8 STATION 49+00 TO 56+00 C9 STATION 56+00 TO 63+00 C10 STATION 63+00 TO 70+00 C11 STATION 70+00 TO 77+00 C12 HDD OVERALL PLAN & PROFILE C13 STATION 77+00 TO 91+00 (PLAN) C14 STATION 91+00 TO 105+00 (PLAN) C15 STATION 105+00 TO 111+00 (PLAN) C16 STATION 77+00 TO 86+00 (PROFILE) C17 STATION 86+00 TO 95+00 (PROFILE) C18 STATION 95+00 TO 104+00 (PROFILE) C19 STATION 104+00 TO 111+00 (PROFILE) C20 STATION 111+00 TO 118+00 C21 STATION 118+00 TO 125+00 LINETYPE NATURAL GAS FORCE MAIN ELECTRIC TELEPHONE WATER LINE FIBER OPTIC CABLE TREELINE CABLE TV OVERHEAD ELECTRICAL UNDERGROUND ELECTRICAL DITCH INTERMEDIATE CONTOUR EXISTING FENCE PROPERTY LINE EASEMENT LINE STRUCTURE SANITARY SEWER PROPOSED PERMANENT EASEMENT TEMPORARY CONSTRUCTION EASEMENT DETAILS D1 STANDARD DETAILS C24 STATION 139+00 TO 146+00 C23 STATION 132+00 TO 139+00 C22 STATION 125+00 TO 132+00 C14 BUFFER ZONE 1 BUFFER ZONE 2 FORCEMAIN DURHAM BUFFER SYMBOLS LIGHT POLE GUY WIRE ANCHOR EXISTING MANHOLE PROPOSED ARV MANHOLE VALVE INDEX CONTOUR150 TEMPORARY BENCHMARK D2 STANDARD DETAILS D3 STANDARD DETAILS POWER POLE D4 STANDARD DETAILS D5 STANDARD DETAILS D6 STANDARD DETAILS D7 STANDARD DETAILS G2 NOTES VALVE YARD INLET PROTECTION TPF TREE PROTECTION FENCE SF SILT FENCE DIVERSION SWALE GRAVEL CONSTRUCTION ENTRANCE LOD LIMITS OF DISTURBANCE EROSION CONTROL TEL PED FLARED END SECTION ABBREVIATIONS EOP LOD OHE SSEDGE OF PAVEMENT LIMITS OF DISTURBANCE OVERHEAD ELECTRIC SANITARY SEWER FOC FIBER OPTIC CABLE W WATER G GAS PROPERTY LINE CENTER LINE LP LIGHT POLE UGE UNDERGROUND ELECTRIC PP POWER POLE PL CL ROLLED EROSIONRECM CONTROL MATTING ACF ANNUAL CHANCE FLOOD UGT UNDERGROUND TELEPHONE CHANNEL LINING FFT FIBER FILTRATION TUBE NCG01 GROUND STABLIZIATION AND MATERIALS HANDLING NCG02 SELF-INSPECTION, RECORDKEEPING, AND REPORTING PLOT DATE: 1/20/2021 9:05 AM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\GENERAL\G2 Saved by AMARCH Save date: 11/5/2020 2:44 PMSNOW HILL ROAD FORCEMAIN 31453-000 01 JANUARY 2021B. PORTER IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 WHARTON-SMITH, INC. 5601 77 CENTER DRIVE #120, CHARLOTTE, NORTH CAROLINA 28217 90% SUBMITTAL - NOT FOR CONSTRUCTION N. JOHNSON E. NG G2 NOTES B. PORTER GENERAL 1.THE CONTRACTOR IS SOLELY RESPONSIBLE FOR SITE SAFETY ASSOCIATED WITH THE WORK UNDER THIS PROJECT AND FOR COMPLIANCE WITH ALL FEDERAL, STATE AND LOCAL HEALTH AND SAFETY LAWS, CODES, REGULATIONS, AND ORDINANCES INCLUDING, BUT NOT LIMITED TO, THOSE CURRENTLY MANDATED BY THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA). 2.CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE DESIGN, INSTALLATION, AND MAINTENANCE OF ALL EXCAVATION SUPPORT ON THE PROJECT. ALL EXCAVATION SUPPORT SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF NORTH CAROLINA. ALL EXCAVATION SUPPORT DESIGN DOCUMENTS SHALL BE PRESENTED TO THE ENGINEER FOR REVIEW BEFORE IMPLEMENTATION. CONTRACTOR SHALL USE ADEQUATE SHORING METHODS TO ENSURE: A.COMPLIANCE WITH OSHA REGULATIONS. B.PROTECTION OF EXISTING PAVEMENT AND ROAD SHOULDERS, STRUCTURES AND UTILITIES. C.CONSTRUCTION ACTIVITIES ARE CONFINED TO RIGHTS-OF-WAY OR EASEMENTS AS INDICATED 3.LIMITS OF DISTURBANCE (LOD) SHALL BE AS INDICATED ON THE CONTRACT DRAWINGS. ANY CHANGES TO THE LOD BY THE CONTRACTOR SHALL REQUIRE PRIOR APPROVAL FROM THE ENGINEER AND DEMLR LAND QUALITY SECTION. 4.CONTRACTOR SHALL REPAIR AT HIS OWN EXPENSE, ANY DAMAGE CAUSED BY CONSTRUCTION RELATED ACTIVITIES TO EXISTING UTILITY SERVICE LINES. 5.IN THE EVENT OF DAMAGE TO EXISTING UTILITIES, CONTRACTOR SHALL STOP WORK IMMEDIATELY, TAKE NECESSARY PRECAUTIONS TO PREVENT INJURY OR FURTHER DAMAGE, AND NOTIFY PROPER AUTHORITIES. CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING/REPAIRING ALL EXISTING STRUCTURES, CONDUITS, OR OTHER UTILITIES DAMAGED BY CONTRACTOR'S OPERATIONS AT NO COST TO OWNER. 6.REMOVAL AND REPLACEMENT OR REPAIR OF EXISTING UTILITY SERVICES SHALL BE COORDINATED WITH APPROPRIATE UTILITY COMPANY AT NO ADDITIONAL COST TO THE OWNER. 7.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL AND REPLACEMENT TO ORIGINAL OR BETTER CONDITION OF ALL EXISTING PAVEMENTS, FENCES, AND MISCELLANEOUS ITEMS WHERE DAMAGED BY CONSTRUCTION ACTIVITIES OR REQUIRED TO COMPLETE THE CONSTRUCTION. 8.ALL HOLES, TRENCHES, AND OTHER HAZARDOUS AREAS SHALL BE ADEQUATELY PROTECTED BY BARRICADES, LIGHTS OR OTHER PROTECTIVE DEVICES. 9.REMOVAL OF EXCAVATED MATERIALS AND DAILY CLEANUP OPERATIONS SHALL BE PERFORMED IN COMPLIANCE WITH THE SPECIFICATIONS AND TO THE SATISFACTION OF THE OWNER/ENGINEER. 10.EXCESS/UNSUITABLE SPOIL TO BE REMOVED FROM SITE. PRIOR TO BEGINNING CONSTRUCTION, CONTRACTOR SHALL SUBMIT THE OFF-SITE SPOIL LOCATIONS TO BE USED AND PROVIDE DOCUMENTATION OF EROSION CONTROL MEASURES TO BE PROVIDED DURING DISPOSAL OPERATIONS. CONTRACTORS OFF-SITE SEDIMENT CONTROL MEASURES MUST BE APPROVED BY NC DEMLR PRIOR TO SPOIL DISPOSAL. 11.ALL EROSION AND SEDIMENTATION CONTROLS SHALL BE IMPLEMENTED BEFORE CONSTRUCTION COMMENCES AND SHALL NOT BE REMOVED UNTIL PERMANENT GROUND COVER STABILIZATION HAS BEEN ESTABLISHED. 12.THE CONTRACTOR SHALL RECORD AND SUPPLY TO THE ENGINEER THE FOLLOWING INFORMATION: A.THE LOCATION OF ALL UTILITIES CROSSED AND THE NEW LOCATION AND DEPTH OF ALL RELOCATED AND/OR ADJUSTED UTILITIES. 13.DAMAGED OR REMOVED DRIVEWAY CULVERTS SHALL BE REPLACED WITH THE SAME SIZE AND MATERIAL THAT EXISTED PRIOR TO CONSTRUCTION AND BE IN COMPLIANCE WITH CURRENT NCDOT STANDARDS. NCDOT REQUIRES A MINIMUM OF 15" RCP FOR ALL NEW AND REPLACED CULVERTS. APPLY APPROPRIATE EROSION & SEDIMENTATION CONTROL MEASURES TO ALL RESTORED AREAS INCLUDING DITCH LINES, SWALES, AND CULVERTS. 14.THE CONTRACTOR SHALL PROVIDE ADEQUATE SUPPORT FOR ALL UTILITY POLES AS NECESSARY. COMPACT TRENCH FIVE (5) FEET EACH SIDE OF UTILITY POLES TO A MINIMUM OF 95% STANDARD PROCTOR. THE CONTRACTOR SHALL COORDINATE UTILITY POLE SUPPORT WITH THE APPROPRIATE UTILITY COMPANIES. 1.CONTRACTOR TO POST EROSION CONTROL PERMIT ON JOB SITE AS REQUIRED. 2.ALL EROSION CONTROL MEASURES SHALL BE IN PLACE BEFORE ANY LAND CLEARING OR DISTURBANCE ACTIVITIES MAY BEGIN. 3.A RAIN GAUGE SHALL BE MAINTAINED IN GOOD WORKING ORDER ON THE SITE UNLESS ANOTHER RAIN-MONITORING DEVICE HAS BEEN APPROVED BY THE NC DIVISION OF WATER QUALITY. A WRITTEN RECORD OF THE DAILY RAINFALL AMOUNTS SHALL BE RETAINED AND ALL RECORDS SHALL BE MADE AVAILABLE TO THE DIVISION OF WATER QUALITY. REFER TO THE NC NPDES GENERAL PERMIT NCG010000, SECTION II.B.(3)(B), FOR ADDITIONAL INFORMATION. 4.THE CONTRACTOR SHALL FURNISH AND INSTALL ALL NECESSARY EROSION CONTROL MEASURES WHETHER OR NOT SHOWN ON THE PLANS TO PROTECT ADJACENT CREEKS, RIVERS, ROADWAYS, ETC. FROM SILTATION AND EROSION. 5.ALL EROSION CONTROL MEASURES SHALL BE INSPECTED WEEKLY AND WITHIN 24 HOURS OF ANY RAINFALL EVENT THAT PRODUCES 1/2 INCH OR MORE OF RAIN. REPAIR AND/OR REPLACE AS NECESSARY. SEE STANDARD DETAILS ON CONTRACT SHEET DC3 FOR SPECIFIC MAINTENANCE REQUIREMENTS FOR EACH EROSION AND SEDIMENT CONTROL MEASURE UTILIZED ON THIS PROJECT. 6.EROSION CONTROL MEASURES SHALL BE CLEANED OF ACCUMULATED SEDIMENT WHEN VOLUME OF MEASURE IS HALF FULL. SEDIMENT SHALL BE REMOVED FROM BEHIND SILT FENCING WHEN IT BECOMES APPROXIMATELY 0.5 FEET DEEP AT THE FENCE. THE SEDIMENT FENCE SHALL BE REPAIRED AS NECESSARY TO MAINTAIN THE BARRIER. REMOVED SEDIMENT SHALL BE DISPOSED OF IN SUCH A MANNER AS TO PREVENT FURTHER SEDIMENT TRANSPORT. IF NO SUITABLE ON-SITE LOCATIONS ARE AVAILABLE, ALL REMOVED SEDIMENT WILL BE LEGALLY DISPOSED OF OFF-SITE AT NO ADDITIONAL COST TO THE OWNER. 7.ALL EXCESS SOIL RESULTING FROM EARTHWORK OPERATIONS SHALL BE REMOVED FROM SITE BY CONTRACTOR. ALL TEMPORARY SOIL STOCKPILE AREAS USED FOR BACKFILL AND OTHER ACTIVITIES SHALL BE WITHIN THE LOD AS SHOWN ON THE DRAWINGS, AND LOCATED, AT A MINIMUM, 50 FEET FROM ANY SURFACE WATERS. STOCKPILE SIDE SLOPES SHALL BE NO STEEPER THAN 3:1 AND TOP OF STOCKPILE SHALL BE SLOPED AT A MINIMUM OF 5% TO PROMOTE POSITIVE DRAINAGE. ALL ONSITE TEMPORARY SOIL STOCKPILES SHALL BE SEEDED WITH TEMPORARY AND/OR PERMANENT SEEDING MEASURES FOR THE DURATION OF CONSTRUCTION ACTIVITIES. ALL CONTRACTOR STAGING AND LAYDOWN AREAS, SOIL OR WASTE STOCKPILE AREAS SHALL HAVE PERIMETER SILT FENCE. LOCATED NO CLOSER THAN 6 FEET FROM TOE OF SLOPE TO ALLOW FOR ACCESS AND MAINTENANCE. ANY SOILS TAKEN OFF SITE BECOMES THE CONTRACTORS RESPONSIBILITY AND SHALL COMPLY WITH ALL REQUIRED STATE AND LOCAL REGULATIONS AND PERMITS. 8.ALL EROSION CONTROL MEASURES SHALL REMAIN IN PLACE UNTIL ENTIRE SITE IS PERMANENTLY STABILIZED WITH VEGETATION AS PER SEEDING SPECIFICATIONS AND SCHEDULE. ALL TEMPORARY EROSION CONTROL DEVICES ARE TO BE REMOVED AFTER PERMANENT STABILIZATION HAS BEEN ACHIEVED AND APPROVAL HAS BEEN GRANTED BY THE LAND QUALITY SECTION AND ENGINEER. 9.RESTORE ALL DISTURBED AREAS INCLUDING DITCHES/SWALES, STAGING/LAYDOWN/PARKING AREAS TO ORIGINAL GRADE AND ELEVATION AND ORIGINAL OR BETTER CONDITION, EXCEPT WHERE NOTED ON THE CONTRACT DRAWINGS. 1.CONTRACTOR SHALL SIGN AND IMPLEMENT THE REQUIREMENTS OF THE STATE APPROVED EROSION CONTROL PLAN AND THE NORTH CAROLINA NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) GENERAL PERMIT FOR STORMWATER DISCHARGES ASSOCIATED WITH CONSTRUCTION ACTIVITY. THE CONTRACTOR SHALL NOTIFY THE STATE LAND QUALITY SECTION AT (919) 791-4200 TO SCHEDULE A PRE-CONSTRUCTION MEETING. ADDITIONALLY, THE CONTRACTOR SHALL NOTIFY THE STATE LAND QUALITY SECTION, AT (919) 791-4200 AT LEAST 48 HOURS PRIOR TO BEGINNING CONSTRUCTION ACTIVITIES. EROSION AND SEDIMENT CONTROL (E&SC) PERMIT AND A CERTIFICATE OF COVERAGE (COC) MUST BE OBTAINED BEFORE AND LAND DISTURBING ACTIVITIES OCCUR. 2.INSTALL ALL PERIMETER TEMPORARY SEDIMENT AND EROSION CONTROL MEASURES IN LOCATIONS AS SHOWN ON THE CONTRACT DRAWINGS. THIS INCLUDES, BUT IS NOT LIMITED TO, THE INSTALLATION OF SILT FENCE, TREE PROTECTION FENCE, AND, GRAVEL CONSTRUCTION ENTRANCE. NO CONSTRUCTION OR LAND DISTURBANCE ACTIVITIES MAY BEGIN UNTIL ALL TEMPORARY SEDIMENT AND EROSION CONTROL MEASURES HAVE BEEN INSTALLED. CLEAR ONLY THE AREA REQUIRED FOR INSTALLATION OF EROSION CONTROL MEASURES. 3.ONCE ALL TEMPORARY PERIMETER EROSION CONTROL MEASURES HAVE BEEN INSTALLED, THE SITE SHALL BE CLEARED AND GRUBBED, AS REQUIRED, WITHIN THE LIMITS OF DISTURBANCE (LOD) AS SHOWN ON THE CONTRACT DRAWINGS (C2). ANY ADJUSTMENTS TO THE LOD SHALL REQUIRE PRIOR APPROVAL FROM THE ENGINEER AND OWNER. 4.ALL DEBRIS FROM TREE CLEARING SHALL BE REMOVED FROM SITE. NO BURNING OF DEBRIS WILL BE ALLOWED. 5.ONCE ALL TREE CLEARING HAS BEEN COMPLETED, CONTRACTOR SHALL REROUTE THE 4" SANITARY SEWER LINE AS SHOWN ON CONTRACT DRAWING C4. CONTRACTOR SHALL PHASE CONSTRUCTION AS TO NOT INTERFERE WITH EXISTING FLOW THROUGH THE SEWER. ONCE THE EXISTING SANITARY SEWER HAS BEEN REROUTED, CONTRACTOR MAY BEGIN EXCAVATION AND PHASE 2 SITE ACTIVITIES. ALL EROSION CONTROL PRACTICES SHALL REMAIN IN PLACE WHEN CONSTRUCTION TRANSITIONS TO PHASE 2. 6.PHASE 2 INCLUDES ALL SITE ACTIVITIES FOR THE CONSTRUCTION OF THE NEW PUMP STATION. THIS INCLUDES ADDITIONAL REROUTING OF SEWER/UTILITIES, AND CONSTRUCTION OF THE PUMP STATION AND ASSOCIATED FACILITIES, ROADWAY, AND PIPING. 7.ALL EXCESS SOIL RESULTING FROM ANY EARTHWORK OPERATIONS NECESSARY SHALL BE REMOVED FROM SITE BY CONTRACTOR. ANY SOILS TAKEN OFFSITE BECOMES THE CONTRACTOR'S RESPONSIBILITY, AND SHALL COMPLY WITH ALL REQUIRED STATE AND LOCAL REGULATIONS AND PERMITS. 8.TEMPORARY SEEDING MEASURES SHALL BE EMPLOYED AS SOON AS PRACTICABLE ON DISTURBED AREAS BUT IN ANY EVENT WITHIN FOURTEEN (14) DAYS. DISTURBED SLOPES STEEPER THAN 3:1 SHALL BE TEMPORARILY SEEDED WITHIN SEVEN (7) DAYS UNLESS SLOPE LENGTH IS TEN (10) FEET OR LESS AND NOT STEEPER THAN 2:1. DISTURBED SLOPES 3:1 OR FLATTER SHALL BE TEMPORARILY SEEDED WITHIN FOURTEEN (14) DAYS UNLESS SLOPE LENGTH IS GREATER THAN 50 FEET. 9.WHEN THE PROJECT IS COMPLETE, THE PERMITTEE SHALL CONTACT DEMLR TO CLOSE OUT THE E&SC PLAN. AFTER DEMLR INFORMS THE PERMITTEE OF THE PROJECT CLOSE OUT, VIA INSPECTION REPORT, THE PERMITTEE SHALL VISIT DEQ.NC.GOV/NCG01 TO SUBMIT AN ELECTRONIC NOTICE OF TERMINATION (E-NOT). A $100 ANNUAL GENERAL PERMIT FEE WILL BE CHARGED UNTIL THE E-NOT HAS BEEN FILLED OUT. 10.THE DESIGN PROFESSIONAL (A NCPE, NCPLS, OR NCRLA - AS REQUIRED) SHALL SUBMIT ONE (1) SET OF AS-BUILT DRAWINGS TO THE PUBLIC WORKS DEPARTMENT - DEVELOPMENT REVIEW FOR REVIEW AND APPROVAL. AS-BUILT DRAWING APPROVAL IS REQUIRED PRIOR TO WATER METER INSTALLATION AND/OR SANITARY SEWER SERVICE CONNECTION AND PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY. CONSTRUCTION SEQUENCEEROSION CONTROL DURHAM PLANNING GENERAL CONDITIONS OF APPROVAL - LANDSCAPING NOTES: 1.LANDSCAPE MULCH: PINE STRAW SHALL NOT BE USED AS MULCH OR GROUNDCOVER WITHIN TEN FEET OF ANY STRUCTURES CONSISTING OF EXTERIOR COMBUSTIBLE CONSTRUCTION AS SPECIFIED BY DURHAM CITY CODE SECTION 46-87. 2.LANDSCAPING/C.O. STANDARDS NOTE: ALL LANDSCAPING MUST BE IN PLACE PRIOR TO REQUEST FOR A CERTIFICATE OF COMPLIANCE. CONTACT DURHAM CITY COUNTY PLANNING DEPARTMENT SITE COMPLIANCE STAFF FOR INSPECTION 3.LANDSCAPE RE-INSPECTION FEE: EACH LANDSCAPING COMPLIANCE INSPECTION AFTER THE INITIAL INSPECTION WILL INCUR A RE-INSPECTION FEE. PAYMENT MUST BE RECEIVED BY THE DURHAM CITY COUNTY PLANNING DEPARTMENT PRIOR TO RE-INSPECTION. 4.UNDISTURBED LANDSCAPE BUFFERS: 60-FOOT WIDE UNDISTURBED LANDSCAPE BUFFER. NO CLEARING OR GRADING OTHER THAN SELECTIVE THINNING AND ORDINARY MAINTENANCE OF EXISTING VEGETATION PERMITTED. 5.CONSTRUCTION IN PRESERVED TREE COVERAGE AREAS (UDO SECTION 8.3): A.PRESERVED TREE COVERAGE AREAS SHALL NOT BE USED FOR ACTIVE RECREATIONAL PURPOSES, EXCEPT FOR WALKING PATHS AND FOOT TRAILS CONSTRUCTED WITH MINIMAL DISTURBANCE OF TREE ROOTS AND EXISTING VEGETATION PROVIDED A REGISTERED ARBORIST HAS CERTIFIED THAT THE CONSTRUCTION OF THE TRAIL HAS BEEN DESIGNED TO MINIMIZE IMPACT TO THE EXISTING TREES. NO TREE OVER 10 INCHES SHALL BE REMOVED FOR THE CONSTRUCTION OF TRAILS. SITE PLAN APPROVAL IS REQUIRED FOR CONSTRUCTION OF TRAILS IN PRESERVED TREE COVERAGE AREAS. B.ALL BUILDINGS SHALL BE SET BACK AT LEAST 10 FEET FROM THE EDGE OF ANY PRESERVED TREE COVERAGE AREA. C.UTILITY LINES AND DRAINAGE CHANNELS SHALL BE MINIMIZED WITHIN THE ROOT PROTECTION ZONES OF THE TREES TO BE SAVED. 6.TREE PROTECTION FENCING MUST BE IN PLACE PRIOR TO ANY DEMOLITION, LAND DISTURBANCE, OR ISSUANCE OF A GRADING PERMIT AND SHALL INCLUDE WARNING SIGNS POSTED IN BOTH ENGLISH AND SPANISH, AS FOLLOWS: "NO TRESPASSING/TREE PROTECTION AREA/PROHIBIDO ENTRAR / ZONA PROTECTORA PARA LOS ÁRBOLES." 7.ROOT PROTECTION ZONE EQUALS ONE FOOT OF RADIUS FOR EVERY INCH OF DIAMETER OF EXISTING TREES OR SIX FOOT RADIUS, WHICHEVER IS GREATER NO DISTURBANCE IS ALLOWED IN THIS AREA. AREA IS TO BE PROTECTED WITH BOTH TREE PROTECTION FENCING AND WARNING SIGNS. 8.AT THE START OF GRADING INVOLVING THE LOWERING OF EXISTING GRADE AROUND A TREE OR STRIPPING OF TOPSOIL, A CLEAN, SHARP, VERTICAL CUT SHALL BE MADE AT THE EDGE OF THE TREE SAVE AREA PRIOR TO OR AT THE SAME TIME AS SILT FENCE AND OTHER EROSION CONTROL MEASURES ARE INSTALLED. THE TREE PROTECTION FENCING SHALL BE INSTALLED ON THE SIDE OF THE CUT FARTHEST AWAY FROM THE TREE TRUNK AND SHALL REMAIN IN PLACE UNTIL ALL CONSTRUCTION IN THE VICINITY OF THE TREES IS COMPLETE. NO STORAGE OF MATERIALS, FILL, OR EQUIPMENT AND NO TRESPASSING SHALL BE ALLOWED WITHIN THE BOUNDARY OF THE PROTECTED AREA. 9.CONSTRUCTION DRAWINGS AND SITE PLAN APPROVALS FOR THIS PROJECT ON CONTINGENT ON RECEIVING STORMWATER APPROVAL FROM NCDEQ. FAILURE TO OBTAIN APPROVAL FROM THE STATE SHALL NULIFY ANY PREVIOUS CITY OF DURHAM SITE PLAN APPROVALS FOR THE PROJECT. Xref ..\_Titleblocks\31453-000 - ANSI D-TB.dwg SEED*** MIXTURE PLANTING SEASON LIME*FERTILIZER* STRAW MULCH*COMMENTS P TS AUG 15 - MAY 1 MAY 1 - AUG 15 4000 7504000 4000 4000 4000 750 4000 FERTILIZER SHALL BE 10-10-10 ANALYSIS. TEMPORARY SUMMER SEEDING (LB/AC) P - TS - TW - * ** *** APPLICATION RATES IN POUNDS/ACRE OVERSEED WITH TYPE P SEED MIXTURE DURING NEXT PLANTING SEASON OVERSEED WITH TYPE P SEED MIXTURE DURING NEXT PLANTING SEASON LIME SHALL BE APPLIED AT A MINIMUM OF 2 TONS PER ACRE WITH 3 TONS PER ACRE IN CLAY SOILS. APPLICATION RATES AND/OR CHEMICAL ANALYSIS SHALL BE CONFIRMED OR ESTABLISHED BY SOIL TEST. TACK MULCH BY APPLYING AT 0.10 GAL/YD² SEEDBED PREPARATION NOTES: 1.SCARIFY 2" DEPTH OF SUBGRADE PRIOR TO PLACING TOPSOIL. 2.TOPSOIL SHALL BE SPREAD AT 4" INCH CONSOLIDATED DEPTH 3.APPLY SEED UNIFORMLY WITH A CYCLONE SEEDER, DROP-TYPE SPREADER, OF HYDROSEEDER ON A FIRM, FRIABLE SEEDBED. IN FINE SOILS, SEEDS SHOULD BE DRILLED 1/4 - 1/2 INCH. IN COARSE, SANDY SOILS, SEEDS SHALL BE PLANTED NO DEEPER THAN 3/4 INCH. COVER BROADCAST SEED BY LIGHTLY RAKING OR CHAIN DRAGGING; THEN FIRM SURFACE WITH A ROLLER OR CULTIPACKER TO PROVIDE GOOD SEED CONTACT. TW AUG 15 - MAY 1 1000 25% DEERTONGUE (Dichanthelium clandestinum) 30% LITTLE BLUESTEM (Schicaryium scoparium) 10% INDIAN WOODOATS (Chasmanthium latifolium) 25% VIRGINIA WILDRYE (Elymus virginicus) 10% SOFT RUSH (Juncus effusus) TEMPORARY WINTER, SPRING, FALL SEEDING (LB/AC) RYE GRAIN (Secale cereale) WHEAT (Triticum aestivum) BROWNTOP MILLET (Urochloa ramosa) GERMAN MILLET (Setaria italica) ****ACTUAL QUANTITY OF BULK SEED IS LARGER, AND IS CALCULATED AS THE REQUIRED PURE LIVE SEED DIVIDED BY BOTH THE GERMINATION AND PURITY. ENSURE SEEDS ARE PROPERLY STRATIFIED, IF APPLICABLE, IN ORDER TO ACHIEVE GERMINATION NOTED ON SEED TAG. SEED MIXTURES TO BE USED ON THE PROJECT SHALL BE AS FOLLOWS (ACCEPTABLE SUBSTITUTES PER SECTION 6.24 OF THE NC EROSION AND SEDIMENTATION CONTROL PLANNING AND DESIGN MANUAL MUST BE APPROVED BY ENGINEER) PERMANENT SEEDING RIPARIAN MIX (15 LB/AC PURE LIVE SEED****) LAWN MIX (150 LB/AC) TALL FESCUE SEEDING AND LANDSCAPING 250 255 260 265 270 275 250 255 260 265 270 275 -1+00 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+0020" 45° BENDSTA 0+9520" 45° BENDSTA 1+0520" 45° VERT BENTSTA 0+1620" 45° VERT BENDSTA 0+1220" 45° BENDSTA 1+3620" 45° BENDSTA 1+2220" 45° BENDSTA 0+0720" 45° BENDSTA 0+00SOILSOILSOIL OHE OHE OHE OHE OHE OHE OHEOHEOHEOHE OHE OHE OHE ARV MANHOLERIM = 268.6'TOP OF ARV = 263.8'+/-TOP OF 12" DIP = 261.3'+/-MANHOLE FULL OF WATERCANNOT SEE PIPEVERIFY SIZEGAS GAS GAS FM FM FM FM FM FM FM FM FM W W W W W W W W W W WWW W W W W W F M FMFMFMW W W W W W W W W W W W FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM TBM BENCHTIE SET IN 24" PINE NAVD '88 ELEV: 271.92' 0 + 0 0 1 + 0 0 2+00 3+00 4+00 5+00 6+00 7+00 STA 0+95 20" 45° BEND STA 1+05 20" 45° BEND STA 1+22 20" 45° BEND STA 1+36 20" 45° BENDSTA 0+07 20" 45° BEND STA 0+12 20" 45° VERT BEND STA 0+16 20" 45° VERT BENT 265 26527527 0 2 7 5 275SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF SF SF SF S F SFSF SFLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD FFT FFT 266267268 269270 271 PLAN 1" = 30' PROFILE H: 1" = 30' V: 1" = 3'PLOT DATE: 1/19/2021 12:41 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C1 Saved by AMARCH Save date: 11/9/2020 11:08 AMSNOW HILL ROAD FORCEMAIN 31453-000 01 JANUARY 2021B. PORTER IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 WHARTON-SMITH, INC. 5601 77 CENTER DRIVE #120, CHARLOTTE, NORTH CAROLINA 28217 90% SUBMITTAL - NOT FOR CONSTRUCTION N. JOHNSON E. NG C1 20" FORCE MAIN PLAN AND PROFILE STATION 0+00 TO 7+00 B. PORTER MATCHLINE - STA 7+00 SEE SHEET C2NOTES: 1.REMOVE EXISTING RESTRAINED JOINT PLUG AND MAKE CONNECTION TO EXISTING 20" FM. 2.ELEVATIONS OF UTILITIES SHOWN IN THE PROFILE ARE APPROXIMATE. 3.CONTRACTOR SHALL VERIFY OD OF EXISTING ARV MH AHEAD OF PIPE INSTALLATION AND DEFLECT NEW FM AS NECESSARY AROUND EXISTING MH. 4.LOD LINE IS NOT SHOWN CONTINUOUSLY FOR CLARITY. THE LIMITS OF DISTURBANCE SHALL BE COINCIDENT WITH THE PROPOSED EASEMENT LIMITS AND PROPOSED TEMPORARY EASEMENT LIMITS WHERE NO LOD IS SHOWN. AFTER THE NEW 20" FORCE MAIN IS IN SERVICE, ABANDON EXISTING ARV MH IN PLACE. RETURN ARV AND VALVES TO THE CITY OF DURHAM.SNOW HILL RD (SR 1631) 20" FORCE MAIN, TYP20'20' PERMANENT EASEMENT, TYP EX TEL, TYP EX 30" DIP, TYP EX 12" FM, TYP EXISTING GRADE, TYP 20" PC 350 DIP FORCE MAIN, TYP EX 42" W EL 265.45± MIN 18" E X 4 2 " W E X 2 4 " W EX 24" W EL 266.25± EX 42" W EL 265.16± UNITED STATES OF AMERICA ATTN: US ARMY CORPS OF ENGINEERS D.B. 1057, PG. 659 ADDRESS: 2324 SNOW HILL ROAD JUDITH STAFFORD D.B. 7527, PG. 899 ADDRESS: 2320 SNOW HILL ROAD UNITED STATES OF AMERICA ATTN: US ARMY CORPS OF ENGINEERS D.B. 1057, PG. 659 ADDRESS: 2324 SNOW HILL ROAD10'10' PERMANENT EASEMENT, TYP10'SEE NOTE 1 SILT FENCE, TYP. C-31-0400 FIBER FILTRATION TUBE C-31-0424 LIMITS OF DISTURBANCE, SEE NOTE 4 TREE PROTECTION FENCE, TYP. C-31-0404 SEE NOTE 3 190 LF RESTRAINED JOINT SEE NOTE 3 245 250 255 260 265 270 245 250 255 260 265 270 7+00 8+00 9+00 10+00 11+00 260 265 270 275 280 285 260 265 270 275 280 285 11+00 12+00 13+00 14+0020" 22.5° BENDSTA 7+6320" 22.5° BENDSTA 8+4320" 45° BENDSTA 8+9920" 45° BENDSTA 9+30OHE OHE OHE OHEOHEOHE OHE OHE OHE OHE OHE OHE INV= 260.9'INV= 261.0'INV= 261.1'INV= 261.2'INV= 261.2'87" X 137" CMP87" X 137" CMP87" X 137" CMPINV= 261.2'TBM BENCHTIE SET IN 12" POPLAR NAVD '88 ELEV: 277.25' W W W W W W W W W W W W W W FM FM FM FM FM FMFM FM FMFM FM FM FM FM FM FM FM FMFMFMFMFMFMFMFMFMFM 7+00 8+0 0 9+0010+00 11+00 12+00 13+00 14+00 27 0 275280275270 270 26 5 2 6 5 STA 7+63 20" 22.5° BEND STA 9+30 20" 45° BEND STA 8+99 20" 45° BEND STA 8+43 20" 22.5° BEND 265 FFT FFTFFT FFT FFT FFT FFT FFT FFT FFT FFT FFT FFT FFT FFT FFT FFT FFT FFT FFT FFT FFT LOD LOD LOD LOD LOD LO D LO D LO D LO D LO D LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD FFT FFT FFT FFT FFT FFT FFT FFT FFT FFT FFT FFTFFT FFT FFT FFT FFT FFT FFT FFT FFT FFT FFT FFT FFT FFT FFT FFT FFT FFT FFT FFT FFT PLAN 1" = 30' PROFILE H: 1" = 30' V: 1" = 3'PLOT DATE: 1/19/2021 12:42 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C2 Saved by ENG Save date: 11/12/2020 11:57 AMSNOW HILL ROAD FORCEMAIN 31453-000 01 JANUARY 2021B. PORTER IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 WHARTON-SMITH, INC. 5601 77 CENTER DRIVE #120, CHARLOTTE, NORTH CAROLINA 28217 90% SUBMITTAL - NOT FOR CONSTRUCTION N. JOHNSON E. NG C2 20" FORCE MAIN PLAN AND PROFILE STATION 7+00 TO 14+00 B. PORTERMATCHLINE - STA 7+00 SEE SHEET C1MATCHLINE - STA 14+00 SEE SHEET C3PERMANENT EASEMENT, TYP SNOW HILL RD (SR 1631) 20" FORCE MAIN, TYP WETLAND, TYP EX TEL, TYP EX 30" DIP, TYP EX 12" FM, TYP 10'TYPUNITED STATES OF AMERICA ATTN: US ARMY CORPS OF ENGINEERS D.B. 1057, PG. 659 ADDRESS: 2324 SNOW HILL ROAD EXISTING GRADE, TYP 20" PC 350 DIP FORCE MAIN, TYP UNITED STATES OF AMERICA ATTN: US ARMY CORPS OF ENGINEERS D.B. 1057, PG. 659 ADDRESS: 2324 SNOW HILL ROAD SECRETARY DEPARTMENT OF EDUCATION UNITED STATES OF AMERICA D.B. 945, PG. 631 ADDRESS: 2501 SNOW HILL ROAD CITY OF DURHAM D.B. 2603, PG. 577 P.B.94, PG. 11 ADDRESS: 2414 SNOW HILL ROAD EXISTING GRADE, TYP 20" PC 350 DIP FORCE MAIN, TYP SUSAN WHITSON WEINBERG REVOCABLE TRUST D.B. 6536, PG. 294 P.B. 128, PG. 15 P.B. 143, PG. 13 ADDRESS: 2617 SNOW HILL ROAD CL CREEK10'FIBER FILTRATION TUBE, TYP. C-31-0424 CABIN BRANCH LIMITS OF DISTURBANCE, SEE NOTE 1 216 LF RESTRAINED JOINT NOTES: 1.LOD LINE IS NOT SHOWN CONTINUOUSLY FOR CLARITY. THE LIMITS OF DISTURBANCE SHALL BE COINCIDENT WITH THE PROPOSED EASEMENT LIMITS AND PROPOSED TEMPORARY EASEMENT LIMITS WHERE NO LOD IS SHOWN. 2.THE LIMITS OF DISTURBANCE SHALL NOT EXCEED 30' IN WIDTH WHILE WITHIN REGULATORY STREAM BUFFERS. STREAM CROSSING BYPASS C-35-0700 CHANNEL LINING, TYP. C-31-0470 STREAM BUFFERS, TYP. SEE NOTE 2 X4' WOOD GRAVELGRAVELOHE OHE OHE OHE OHE OHE OH E OH E OH E OH E OHE OHE OHE OHE GRAVELGRAVELINV= 292.4'24" RCPINV= 288.3'30" RCPINV= 285.6'INV= 290.7'15" RCPINV= 320.0'INV= 321.9'W W W W W FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM14+00 15+00 16+00 17+00 18+00 19+00 20+00 21+00 28 0 2 8 5 285 290295295290300305310312315320325330 330 335 3253203153 1 0305300 STA 15+06 20" 45° BEND STA 15+15 20" 45° BEND STA 15+35 20" 45° BEND STA 15+23 20" 45° BEND STA 14+98 2" AIR VACUUM VALVE STA 19+00 3" VACUUM BREAKER VALVE FFT FFT FFT FFT FFT FFT FFT FFT FFT FFT FFT LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD FFT FFT FFT FFT FFT FFT FFT FFT FFT FFTSTREAM E270 275 280 285 290 295 300 270 275 280 285 290 295 300 14+00 15+00 16+00 17+00 280 285 290 295 300 305 310 280 285 290 295 300 305 310 17+00 18+00 295 300 305 310 315 320 325 295 300 305 310 315 320 325 18+00 19+00 20+00 305 310 315 320 325 330 335 305 310 315 320 325 330 335 20+00 21+0020" 45° BENDSTA 15+0620" 45° BENDSTA 15+1520" 45° BENDSTA 15+2320" 45° BENDSTA 15+352" AIR VACUUM VALVESTA 14+983" VACUUM BREAKER VALVESTA 19+00PLOT DATE: 1/19/2021 12:43 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C3 Saved by AMARCH Save date: 11/9/2020 11:12 AMSNOW HILL ROAD FORCEMAIN 31453-000 01 JANUARY 2021B. PORTER IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 WHARTON-SMITH, INC. 5601 77 CENTER DRIVE #120, CHARLOTTE, NORTH CAROLINA 28217 90% SUBMITTAL - NOT FOR CONSTRUCTION N. JOHNSON E. NG C3 20" FORCE MAIN PLAN AND PROFILE STATION 14+00 TO 21+00 ---- SCALE: 1" = 30' PLAN NOTES: 1.REMOVE AND REPLACE EXISTING FENCE AT NEW PERMANENT EASEMENT LINE. 2.LOD LINE IS NOT SHOWN CONTINUOUSLY FOR CLARITY. THE LIMITS OF DISTURBANCE SHALL BE COINCIDENT WITH THE PROPOSED EASEMENT LIMITS AND PROPOSED TEMPORARY EASEMENT LIMITS WHERE NO LOD IS SHOWN. 3.THE LIMITS OF DISTURBANCE SHALL NOT EXCEED 30' IN WIDTH WHILE WITHIN REGULATORY STREAM BUFFERS.MATCHLINESTA 14+00 SEE SHEET C2MATCHLINESTA 21+00 SEE SHEET C410' PERMANENT EASEMENT SNOW HILL RD (SR 1631) 20" FORCE MAIN, TYP PROFILE H: 1" = 30' V: 1" = 3' EX TEL, TYP EX 30" DIP, TYP EX 12" FM, TYP 10'TYPSUSAN WHITSON WEINBERG REVOCABLE TRUST D.B. 6536, PG. 294 P.B. 128, PG. 15 P.B. 143, PG. 13 ADDRESS: 2617 SNOW HILL ROAD JOHN S TUTEN AND WIFE, PATRICIA F. TUTEN D.B. 1040, PG. 95 P.B. 97, PG. 13 ADDRESS: 2600 SNOW HILL ROAD 10'EXISTING GRADE, TYP 20" PC 350 DIP FORCE MAIN, TYP EXISTING GRADE, TYP 20" PC 350 DIP FORCE MAIN, TYPMIN 3.5' COVER CLEAN WATER DIVERSION, TYP. C-31-0440 LIMITS OF DISTURBANCE, SEE NOTE 2 STREAM CROSSING BYPASS SEE NOTE 1 156 LF RESTRAINED JOINT FIBER FILTRATION TUBE, TYP. C-31-0424 FIBER FILTRATION TUBE, TYP. C-31-0424 STREAM BUFFER, TYP. SEE NOTE 3 C-35-0700 CHANNEL LINING, TYP. C-31-0470 315 320 325 330 335 340 315 320 325 330 335 340 21+00 22+00 23+00 325 330 335 340 345 350 325 330 335 340 345 350 23+00 24+00 25+00 26+00 27+00 28+0020" 45° BENDSTA 24+5420" 45° BENDSTA 24+7820" 45° BENDSTA 24+9420" 45° BENDSTA 25+186" BIAS AIR VACUUM VALVESTA 25+502" BIAS AIR VACUUM VALVESTA 21+30X X X X 4' WOOD SOILOHE OHE OHE OHE OHE OHEOHE OHE OHE OHE OHE OHE OHE 15" RCPINV= 320.0'INV= 321.9'ARV MANHOLE RIM = 343.0' TOP OF ARV = 335.8'+/- TOP OF 12" DIP = 333.3'+/- MANHOLE FULL OF WATER CANNOT SEE PIPE W W W W W W W W W W W FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM UGECATVCATVTFM FM FM FM FM FM FM FM FM FM FM FM FM 21+00 22+00 23+00 24+00 25+0026+00 27+00 28+00 340340 340330330325325 335335STA 24+54 20" 45° BEND STA 24+78 20" 45° BEND STA 24+94 20" 45° BEND STA 25+18 20" 45° BEND SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD CONC RETE STA 21+30 2" BIAS AIR VACUUM VALVE STA 25+50 6" BIAS AIR VACUUM VALVE PLAN 1" = 30' PROFILE H: 1" = 30' V: 1" = 3'PLOT DATE: 1/19/2021 12:43 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C4 Saved by ENG Save date: 11/12/2020 12:17 PMSNOW HILL ROAD FORCEMAIN 31453-000 01 JANUARY 2021B. PORTER IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 WHARTON-SMITH, INC. 5601 77 CENTER DRIVE #120, CHARLOTTE, NORTH CAROLINA 28217 90% SUBMITTAL - NOT FOR CONSTRUCTION N. JOHNSON E. NG C4 20" FORCE MAIN PLAN AND PROFILE STATION 21+00 TO 28+00 B. PORTER NOTES: 1.CONTRACTOR SHALL VERIFY OD OF EXISTING ARV MH AHEAD OF PIPE INSTALLATION AND DEFLECT NEW FM AS NECESSARY AROUND EXISTING MH. AFTER THE NEW 20" FORCE MAIN IS IN SERVICE, ABANDON EXISTING ARV MH IN PLACE. RETURN ARV AND VALVES TO THE CITY OF DURHAM. 2.REMOVE AND REPLACE EXISTING FENCE AT NEW PERMANENT EASEMENT LINE. 3.LOD LINE IS NOT SHOWN CONTINUOUSLY FOR CLARITY. THE LIMITS OF DISTURBANCE SHALL BE COINCIDENT WITH THE PROPOSED EASEMENT LIMITS AND PROPOSED TEMPORARY EASEMENT LIMITS WHERE NO LOD IS SHOWN.MATCHLINE - STA 21+00 SEE SHEET C3MATCHLINE - STA 28+00 SEE SHEET C510' PERMANENT EASEMENT, TYP SNOW HILL RD (SR 1631) 20" FORCE MAIN, TYP10'EX TEL, TYP EX 30" DIP, TYP EX 12" FM, TYP 10'JEREMY T. FREEMAN AND WIFE, MIRANDA L. FREEMAN D.B. 6377, PG. 690 P.B. 94, PG. 33 P.B. 148, PG. 45 ADDRESS: 2806 SNOW HILL ROAD CHARLES E. SOUTHALL, JR. D.B. 7182, PG. 484 P.B. 93, PG. 89 ADDRESS: 2818 SNOW HILL ROAD DANIEL T. GLOSSON AND WIFE, PATRICIA A. GLOSSON D.B. 2823, PG. 979 P.B. 148, PG. 45 ADDRESS: 2804 SNOW HILL ROAD BRUCE F. PHILLIPS AND WIFE, BARBARA H. PHILLIPS D.B. 2876, PG. 962 P.B. 148, PG. 45 ADDRESS: 2802 SNOW HILL ROAD SUSAN WHITSON WEINBERG REVOCABLE TRUST D.B. 6536, PG. 294 P.B. 128, PG. 15 P.B. 143, PG. 13 ADDRESS: 2803 SNOW HILL ROAD 10'EXISTING GRADE, TYP 20" PC 350 DIP FORCE MAIN, TYP MIN 3.5' COVER EXISTING GRADE, TYP 20" PC 350 DIP FORCE MAIN, TYP SILT FENCE, TYP. C-31-0400 LIMITS OF DISTURBANCE, SEE NOTE 3 SEE NOTE 1 SEE NOTE 2 165 LF RESTRAINED JOINT CLEAN WATER DIVERSION, TYP. C-31-0440 FIBER FILTRATION TUBE, TYP. C-31-0424 CHANNEL LINING, TYP. C-31-0470 315 320 325 330 335 340 315 320 325 330 335 340 28+00 29+00 30+00 31+00 32+00 310 315 320 325 330 335 310 315 320 325 330 335 32+00 33+00 34+00 35+0020" 45° BENDSTA 31+2220" 45° BENDSTA 31+7220" 45° BENDSTA 31+5020" 45° BENDSTA 31+42X X X X X X XXXXXXXXXXXXXXXXX X X X X 4' WOODGATE 3.5' WOOD3.5' WOOD3.5' WOOD3.5' WOOD 4' WOOD 4' WOOD4' WIRE GRAVELOHEOHEOHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE GRAVELGRAVELGRAVELINV= 331.9'15" RCP INV= 331.0'INV= 320.8'15" RCP INV= 319.5'W W W W W W W W W W W W W UGE TFM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM TBM BENCHTIE SET IN 12" OAK NAVD '88 ELEV: 318.92' 28+00 29+00 30+00 31+00 32+00 33+00 34+00 35+00 STA 31+72 20" 45° BEND STA 31+50 20" 45° BEND STA 31+42 20" 45° BEND STA 31+22 20" 45° BEND 335 3 4 0 335330 330 325 3203 2 0 320320325SF/TPF SF/TPF SF/TPF S F SF SFSF SF SF SF SF SF SF SF SF SF SF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD PLAN 1" = 30' PROFILE H: 1" = 30' V: 1" = 3'PLOT DATE: 1/19/2021 12:44 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C5 Saved by ENG Save date: 11/12/2020 2:18 PMSNOW HILL ROAD FORCEMAIN 31453-000 01 JANUARY 2021B. PORTER IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 WHARTON-SMITH, INC. 5601 77 CENTER DRIVE #120, CHARLOTTE, NORTH CAROLINA 28217 90% SUBMITTAL - NOT FOR CONSTRUCTION N. JOHNSON E. NG C5 20" FORCE MAIN PLAN AND PROFILE STATION 28+00 TO 35+00 B. PORTER NOTES: 1.REMOVE AND REPLACE EXISTING FENCE AND GATE AT NEW PERMANENT EASEMENT LINE. 2.LOD LINE IS NOT SHOWN CONTINUOUSLY FOR CLARITY. THE LIMITS OF DISTURBANCE SHALL BE COINCIDENT WITH THE PROPOSED EASEMENT LIMITS AND PROPOSED TEMPORARY EASEMENT LIMITS WHERE NO LOD IS SHOWN.MATCHLINE - STA 28+00 SEE SHEET C4MATCHLINE - STA 35+00 SEE SHEET C610' PERMANENT EASEMENT, TYP SNOW HILL RD (SR 1631) 20" FORCE MAIN, TYP10'EX TEL, TYP EX 30" DIP, TYP EX 12" FM, TYP 10'SOUTHALL ROSE JONES D.B. 6003, PG. 328 P.B. 143, PG. 13 ADDRESS: 2807 SNOW HILL ROAD CHARLES E. SOUTHALL, SR., & CHARLES E. SOUTHALL, JR. D.B. 7182, PG. 488 P.B. 93, PG. 89 ADDRESS: 2820 SNOW HILL ROAD REBECCA S. OLBRYCH, TRUSTEE D.B. 8373, PG. 824 P.B. 135, PG. 101 P.B. 75, PG. 29 ADDRESS: 2910 SNOW HILL ROAD JESSICA L. GOODWIN & RICHARD E. GOODWIN D.B. 8248, PG. 680 P.B. 70, PG. 69 ADDRESS: 3008 SNOW HILL ROADREBECCA GREEN SERCY D.B. 1508, PG. 423 P.B. 135, PG. 101 ADDRESS: 2908 SNOW HILL ROAD VIRGINIA L. HARRIS D.B. 3428, PG. 317 ADDRESS: 2917 SNOW HILL ROAD JARED RAY COATES & JODIE S. COATES D.B. 2335, PG. 456 P.B. 135, PG. 101 ADDRESS: 2918 SNOW HILL ROAD EXISTING GRADE, TYP 20" PC 350 DIP FORCE MAIN, TYP 20" PC 350 DIP FORCE MAIN, TYP EXISTING GRADE, TYP SILT FENCE, TYP. LIMITS OF DISTURBANCE, SEE NOTE 2 TREE PROTECTION FENCE, TYP. C-31-0404 NOTE 1, TYP 165 LF RESTRAINED JOINT FIBER FILTRATION TUBE, TYP. C-31-0424 CHANNEL LINING, TYP. C-31-0470 C-31-0400 295 300 305 310 315 320 295 300 305 310 315 320 35+00 36+00 37+00 285 290 295 300 305 310 285 290 295 300 305 310 37+00 38+00 275 280 285 290 295 300 275 280 285 290 295 300 38+00 39+00 40+00 260 265 270 275 280 285 260 265 270 275 280 285 40+00 41+00 42+00 X X X X X X X X X X X X X X X X X X X X X GATE 4' WIRE 4' WIRE GRAVELGRAVEL4' WIRE OHE OHEOHEOHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE GRAVELGRAVEL4' WIRE INV= 270.2'72" CMPINV= 301.6'18" RCP INV= 300.5'INV= 302.1'15" CMP INV= 301.8'W W W W W W W W W W W W W FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM 35+00 36+00 37+00 38+00 39+00 40+00 41+00 42+00 320 315 310 305 300305310315300295295290285280275 275 280285290275305SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF TPF TPF TPF TPF TPF TPF TPF LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODSTREAM HPLAN 1" = 30' PROFILE H: 1" = 30' V: 1" = 3'PLOT DATE: 1/19/2021 12:45 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C6 Saved by ENG Save date: 11/12/2020 2:19 PMSNOW HILL ROAD FORCEMAIN 31453-000 01 JANUARY 2021B. PORTER IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 WHARTON-SMITH, INC. 5601 77 CENTER DRIVE #120, CHARLOTTE, NORTH CAROLINA 28217 90% SUBMITTAL - NOT FOR CONSTRUCTION N. JOHNSON E. NG C6 20" FORCE MAIN PLAN AND PROFILE STATION 35+00 TO 42+00 B. PORTERMATCHLINE - STA 35+00 SEE SHEET C5MATCHLINE - STA 42+00 SEE SHEET C710' PERMANENT EASEMENT, TYP SNOW HILL RD (SR 1631) 20" FORCE MAIN, TYP EX 30" DIP, TYP EX 12" FM, TYP 10'JESSICA L. GOODWIN & RICHARD E. GOODWIN D.B. 8248, PG. 680 P.B. 70, PG. 69 ADDRESS: 3008 SNOW HILL ROAD EXISTING GRADE, TYP 20" PC 350 DIP FORCE MAIN, TYP SCOTTIE DOUGLAS McFARLAND 215, PG. 458D.B. P.B. 14, PG. 96 P.B. 5A, PG. 65 ADDRESS: 2132 INFINITY ROAD EXISTING GRADE, TYP 20"PC 350 DIP FORCE MAIN, TYP MIN 4' COVER SILT FENCE, TYP. LIMITS OF DISTURBANCE, SEE NOTE 1 CHANNEL LINING, TYP. TREE PROTECTION FENCE, TYP. C-31-0404 NOTES: 1.LOD LINE IS NOT SHOWN CONTINUOUSLY FOR CLARITY. THE LIMITS OF DISTURBANCE SHALL BE COINCIDENT WITH THE PROPOSED EASEMENT LIMITS AND PROPOSED TEMPORARY EASEMENT LIMITS WHERE NO LOD IS SHOWN. 2.THE LIMITS OF DISTURBANCE SHALL NOT EXCEED 30' IN WIDTH WHILE WITHIN REGULATORY STREAM BUFFERS. STREAM BUFFER, TYP SEE NOTE 2POND BUFFER FIBER FILTRATION TUBE, TYP. C-31-0424 C-31-0400 C-31-0470 260 265 270 275 280 285 260 265 270 275 280 285 42+00 43+00 44+00 270 275 280 285 290 295 270 275 280 285 290 295 44+00 45+00 46+00 47+00 48+00 49+00 X X X X X X X X X X X XXX X X X X X X X X X X X X X X X4' WIRE4' BARBE D W I R E 4" BARBED W I R E CABLEGRAVEL4' WIRE 4' WIRE 4' WIRE GRAVELGRAVELOHE OHE OHE OHE OHE OHEOHEOHEOHE OHE OHE OHE OHEOHEOHEOHEOHEOHE OHE OHE OHE OHEGRAVEL4' WIRE 4' WIRE 4' WIRE GRAVELGRAVEL12"RCP INV= 270.2'72" CMPINV= 269.6'INV= 285.9'INV= 285.7'ARV MANHOLERIM = 290.2'TOP OF 12" DIP = 284.9'+/-MANHOLE FULL OF WATERCANNOT SEE PIPE2 ST O R Y WO O D B A R N (ABA N D O N E D ) AB A N D . SH E D 18" HICKORY24" PECANW W W W W W W W W W W W W W WWWW W W W W GASFM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM X X X X X X X X X X X XXX X X X X X X X X X X X X X X X4' WIRE4' BARBE D W I R E 4" BARBED W I R E CABLEGRAVEL4' WIRE 4' WIRE 4' WIRE GRAVELGRAVELOHE OHE OHE OHE OHE OHEOHEOHEOHE OHE OHE OHE OHEOHEOHEOHEOHEOHE OHE OHE OHE OHEGRAVEL4' WIRE 4' WIRE 4' WIRE GRAVELGRAVEL12"RCP INV= 270.2'72" CMPINV= 269.6'INV= 285.9'INV= 285.7'ARV MANHOLERIM = 290.2'TOP OF 12" DIP = 284.9'+/-MANHOLE FULL OF WATERCANNOT SEE PIPE2 ST O R Y WO O D B A R N (ABA N D O N E D ) AB A N D . SH E D 18" HICKORY24" PECANW W W W W W W W W W W W W W WWWW W W W W GASFM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM42+00 43+00 44+00 45+00 46+00 47+00 48+00 49+00 290 285285275280285285 290290290290 290280 SF SF SF SF TPF TPF TPF TPF TPF TPF TPF TPF TPF TPF TPF TPF TPF TPF TPF TPF LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD L O D LODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LODSTREAM HSTA 46+00 20" PLUG VALVE PLAN 1" = 30' PROFILE H: 1" = 30' V: 1" = 3'PLOT DATE: 1/19/2021 12:45 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C7 Saved by ENG Save date: 11/12/2020 2:20 PMSNOW HILL ROAD FORCEMAIN 31453-000 01 JANUARY 2021B. PORTER IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 WHARTON-SMITH, INC. 5601 77 CENTER DRIVE #120, CHARLOTTE, NORTH CAROLINA 28217 90% SUBMITTAL - NOT FOR CONSTRUCTION N. JOHNSON E. NG C7 20" FORCE MAIN PLAN AND PROFILE STATION 42+00 TO 49+00 B. PORTER NOTES: 1.ELEVATION OF UTILITIES SHOWN IN THE PROFILE ARE APPROXIMATE. 2.REMOVE AND REPLACE EXISTING FENCE AND GATES AT THE NEW PERMANENT EASEMENT LINE. 3.LOD LINE IS NOT SHOWN CONTINUOUSLY FOR CLARITY. THE LIMITS OF DISTURBANCE SHALL BE COINCIDENT WITH THE PROPOSED EASEMENT LIMITS AND PROPOSED TEMPORARY EASEMENT LIMITS WHERE NO LOD IS SHOWN. 4.THE LIMITS OF DISTURBANCE SHALL NOT EXCEED 30' IN WIDTH WHILE WITHIN REGULATORY STREAM BUFFERS.MATCHLINE - STA 42+00 SEE SHEET C6MATCHLINE - STA 49+00 SEE SHEET C820' PERMANENT EASEMENT, TYP SNOW HILL RD (SR 1631) 20" FORCE MAIN, TYP INFINITY RD (SR 1639)20'EX TEL, TYP EX 30" DIP, TYP EX 12" FM, TYP EX 30" W EL 285.73± EX 8" GASEX 30" WATEREXISTING GRADE, TYP 20" PC 350 DIP FORCE MAIN, TYP SCOTTIE DOUGLAS McFARLAND D.B. 215, PG. 458 P.B. 14, PG. 96 P.B. 5A, PG. 65 ADDRESS: 2132 INFINITY ROAD SCOTTIE DOUGLAS McFARLAND D.B. 215, PG. 458 P.B. 14, PG. 96 P.B. 5A, PG. 65 ADDRESS: 2132 INFINITY ROAD 91 LF OF 36" STEEL CASING PIPE MINIMUM THICKNESS 0.25" INSTALLED BY TRENCHLESS METHOD EX TEL EX ARV MH RIM = 290.2' TOP OF 12" DIP = 284.9'± MANHOLE FULL OF WATER CANNOT SEE PIPE 91 LF OF 36" STEEL CASING PIPE MINIMUM THICKNESS 0.25" INSTALLED BY TRENCHLESS METHOD MIN 3' SILT FENCE. TYP. C-31-0400 LIMITS OF DISTURBANCE, SEE NOTE 3 FIBER FILTRATION TUBE, TYP. C-31-0424 TREE PROTECTION FENCE, TYP. C-31-0404 MIN 4' COVER SEE NOTE 2 607 LF RESTRAINED JOINT STREAM CROSSING BYPASS C-35-0700 STREAM BUFFER, TYP. SEE NOTE 4 CLEAN WATER DIVERSION, TYP. C-31-0440 CHANNEL LINING, TYP. C-31-0470 270 275 280 285 290 295 270 275 280 285 290 295 49+00 50+00 51+00 52+00 53+00 54+00 55+00 56+0020" 45° BENDSTA 49+1320" 45° BENDSTA 50+6420" 22.5° BENDSTA 50+8720" 45° BENDSTA 49+01XXXXXXXXX X X 4' WIRE3' BARBED WIRECABLE 4' WIRE CABLE GRAVELOHE OHE OHE OHE OHE GRAVEL12"CMP12"RCP INV= 282.4'INV= 282.7'INV= 285.9'INV= 285.7'18" HICKORYW W W W W W W W W FM FM FM FM FM FM FM FM FMFMFMFMFMXXXXXXXXX X X 4' WIRE3' BARBED WIRECABLE 4' WIRE CABLE GRAVELOHE OHE OHE OHE OHE GRAVEL12"CMP12"RCP INV= 282.4'INV= 282.7'INV= 285.9'INV= 285.7'18" HICKORYW W W W W W W W W FM FM FM FM FM FM FM FM FMFMFMFMFMTCETCE49+00 50+00 51+0052+00STA 49+01 20" 45° BEND STA 49+13 20" 45° BEND STA 50+64 20" 45° BEND STA 50+87 20" 22.5° BEND 290 285 SF/TPFSF/TPFSF/TPFSF/TPFSF/TPFTCETCETPF TPF TPF TPF LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODX X X X X X X X X X X X 3' BARBED WIRE FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM TBM BENCHTIE SET IN 15" ELM NAVD '88 ELEV: 289.72' FM X X X X X X X X X X X X 3' BARBED WIRE FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM TBM BENCHTIE SET IN 15" ELM NAVD '88 ELEV: 289.72' FM TCE TCE TCE TCE TCE TCE TCE 52+00 53+00 54+00 55+00 56+00 290 290285 28 5 SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF S F / T P F SF/TPF SF/TPF SF/TPF TCE TCE TCE TCE TCE TCE TCE LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD L O D L O D LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD PLAN 1" = 30' PROFILE H: 1" = 30' V: 1" = 3'PLOT DATE: 1/28/2021 11:59 AM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C8 Saved by AMARCH Save date: 1/18/2021 11:13 AMSNOW HILL ROAD FORCEMAIN 31453-000 01 JANUARY 2021B. PORTER IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 WHARTON-SMITH, INC. 5601 77 CENTER DRIVE #120, CHARLOTTE, NORTH CAROLINA 28217 90% SUBMITTAL - NOT FOR CONSTRUCTION N. JOHNSON E. NG C8 20" FORCE MAIN PLAN AND PROFILE STATION 49+00 TO 56+00 B. PORTERMATCHLINE - STA 49+00 SEE SHEET C7MATCHLINE - STA 56+00 SEE SHEET C9MATCHLINE - STA 52+00 SEE THIS SHEET MATCHLINE - STA 52+00 SEE THIS SHEETPLAN 1" = 30' 20' PERMANENT EASEMENT, TYP SNOW HILL RD (SR 1631) 20" FORCE MAIN, TYP 25'25'25' TEMPORARY CONSTRUCTION EASEMENT, TYP 20" FORCE MAIN, TYP 15' 40' EXISTING 40' EASEMENT, TYP 40'25' TEMPORARY CONSTRUCTION EASEMENT, TYP EXISTING 40' EASEMENT, TYP 15'EX 12" FORCE MAIN, TYP EX 12" FM, TYP 10'SCOTTIE DOUGLAS McFARLAND D.B. 215, PG. 458 P.B. 14, PG. 96 P.B. 5A, PG. 65 ADDRESS: 2132 INFINITY ROAD AGNES S. CRIST & ANAV S. MAGDA ESTATE FILE NO. 1989-E-469 P.B. 82, PG. 47 ADDRESS: 3314 SNOW HILL ROAD SCOTTIE DOUGLAS McFARLAND D.B. 215, PG. 458 P.B. 14, PG. 96 P.B. 5A, PG. 65 ADDRESS: 2132 INFINITY ROAD AGNES S. CRIST & ANAV S. MAGDA ESTATE FILE NO. 1989-E-469 P.B. 82, PG. 47 P.B. 77, PG. 33 ADDRESS: 3326 SNOW VALLEY ROAD EXISTING GRADE, TYP 20" PC 350 DIP FORCE MAIN, TYP MIN 3.5' COVER SILT FENCE, TYP. C-31-0400 LIMITS OF DISTURBANCE, SEE NOTE 2 TREE PROTECTION FENCE, TYP. C-31-0404 NOTES: 1.REMOVE AND REPLACE EXISTING FENCE AND GATE AT NEW PERMANENT EASEMENT LINE ALONG SNOW HILL. FENCE ALONG EXISTING EASEMENT SHALL REMAIN. 2.LOD LINE IS NOT SHOWN CONTINUOUSLY FOR CLARITY. THE LIMITS OF DISTURBANCE SHALL BE COINCIDENT WITH THE PROPOSED EASEMENT LIMITS AND PROPOSED TEMPORARY EASEMENT LIMITS WHERE NO LOD IS SHOWN. 2.THE LIMITS OF DISTURBANCE SHALL NOT EXCEED 30' IN WIDTH WHILE CROSSING STREAM BUFFERS. SEE NOTE 1 607 LF RESTRAINED JOINT TEMPORARY CONSTRUCTION ENTRANCE C-31-0490 FIBER FILTRATION TUBE, TYP. C-31-0424 CHANNEL LINING, TYP. C-31-0470 STREAM BUFFERS, TYP. SEE NOTE 3 275 280 285 290 295 300 275 280 285 290 295 300 56+00 57+00 58+00 59+00 60+00 61+00 62+00 63+00 X X X X X X X X X X X X X X X X X X X 3' BARBED WIRE 3' BARBED WIRE3' BARBED WIRE 3' BARBED WIRESOIL PATHSOIL PATH FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM RIP-RAPRIP-RAPX X X X X X X X X X X X X X X X X X X 3' BARBED WIRE 3' BARBED WIRE3' BARBED WIRE 3' BARBED WIRESOIL PATHSOIL PATH FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM RIP-RAPRIP-RAPTCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE 56+00 57+00 58+00 59+00 60+00 61+00 62+00 63+00 2 9 0 2 9 0 28 5 29 0 2 9 0 2902 9 5 295295 295 29 0 SF/TPF SF/TPF SF/TPF SF/TPF SF/T P F SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD L O D LOD PLAN 1" = 30' PROFILE H: 1" = 30' V: 1" = 3'PLOT DATE: 1/28/2021 11:58 AM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C9 Saved by AMARCH Save date: 1/28/2021 11:56 AMSNOW HILL ROAD FORCEMAIN 31453-000 01 JANUARY 2021B. PORTER IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 WHARTON-SMITH, INC. 5601 77 CENTER DRIVE #120, CHARLOTTE, NORTH CAROLINA 28217 90% SUBMITTAL - NOT FOR CONSTRUCTION N. JOHNSON E. NG C9 20" FORCE MAIN PLAN AND PROFILE STATION 56+00 TO 63+00 B. PORTERMATCHLINE - STA 56+00 SEE SHEET C8MATCHLINE - STA 63+00 SEE SHEET C1020" FORCE MAIN, TYP 25'40'25' TEMPORARY CONSTRUCTION EASEMENT, TYP EXISTING 40' EASEMENT, TYP 15'EX 12" FORCE MAIN, TYP SCOTTIE DOUGLAS McFARLAND D.B. 215, PG 4458 P.B. 14, PG. 96 P.B. 5A, PG. 65 ADDRESS: 2132 INFINITY ROAD AGNES S. CRIST & ANAV S. MAGDA ESTATE FILE NO. 1989-E-469 P.B. 82, PG. 47 P.B. 77, PG. 33 ADDRESS: 3326 SNOW VALLEY ROAD AGNES S. CRIST & ANAV S. MAGDA ESTATE FILE NO. 1989-E-469 P.B. 82, PG. 47 ADDRESS: 2000 SNOW VALLEY ROAD EXISTING 25' EASEMENT, TYP EXISTING GRADE, TYP 20" PC 350 DIP FORCE MAIN, TYP MIN 3.5' COVER SILT FENCE, TYP. C-31-0400 LIMITS OF DISTURBANCE, SEE NOTE 1FIBER FILTRATION TUBE, TYP. C-31-0424 TREE PROTECTION FENCE, TYP. C-31-0404 STREAM CROSSING BYPASS C-35-0700 NOTES: 1.LOD LINE IS NOT SHOWN CONTINUOUSLY FOR CLARITY. THE LIMITS OF DISTURBANCE SHALL BE COINCIDENT WITH THE PROPOSED EASEMENT LIMITS AND PROPOSED TEMPORARY EASEMENT LIMITS WHERE NO LOD IS SHOWN. 2.THE LIMITS OF DISTURBANCE SHALL NOT EXCEED 30' IN WIDTH WHILE CROSSING STREAM BUFFERS. STREAM BUFFERS, TYP. SEE NOTE 2 290 295 300 305 310 315 290 295 300 305 310 315 63+00 64+00 65+00 66+00 300 305 310 315 320 325 300 305 310 315 320 325 66+00 67+00 68+00 310 315 320 325 330 335 310 315 320 325 330 335 68+00 69+00 70+003" AIR VACCUM VALVE(FULL SIZED OUTLET)STA 69+743" BIAS AIR VACCUM VALVESTA 65+75X X X X X X X X X X X XX X X X X X X 3' BARBED WIREGATE3' BARBED WIRE3' BARBED WIRESOIL PATHSOIL PATHGRAVEL 15" RCP INV= 300.5'16" DIP INV= 300.9'ARV MANHOLERIM = 329.0'TOP OF ARV = 327.0'+/-TOP OF 12" DIP = 323.0'+/-FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM TBM BENCHTIE SET IN 8" OAK NAVD '88 ELEV: 331.85' X X X X X X X X X X X XX X X X X X X 3' BARBED WIREGATE3' BARBED WIRE3' BARBED WIRESOIL PATHSOIL PATHGRAVEL 15" RCP INV= 300.5'16" DIP INV= 300.9'ARV MANHOLERIM = 329.0'TOP OF ARV = 327.0'+/-TOP OF 12" DIP = 323.0'+/-FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM TBM BENCHTIE SET IN 8" OAK NAVD '88 ELEV: 331.85' TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE 63+00 64+00 65+00 66+00 67+00 68+00 69+00 70+00 300305310315320325 3 3 0 3 3 0 STA 69+74 3" AIR VACCUM VALVE (FULL SIZED OUTLET) STA 65+75 3" BIAS AIR VACCUM VALVE SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLOD LODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD 330PLAN 1" = 30' PROFILE H: 1" = 30' V: 1" = 3'PLOT DATE: 1/19/2021 12:48 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C10 Saved by ENG Save date: 11/12/2020 2:33 PMSNOW HILL ROAD FORCEMAIN 31453-000 01 JANUARY 2021B. PORTER IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 WHARTON-SMITH, INC. 5601 77 CENTER DRIVE #120, CHARLOTTE, NORTH CAROLINA 28217 90% SUBMITTAL - NOT FOR CONSTRUCTION N. JOHNSON E. NG C10 20" FORCE MAIN PLAN AND PROFILE STATION 63+00 TO 70+00 B. PORTERMATCHLINE - STA 63+00 SEE SHEET C9MATCHLINE - STA 70+00 SEE SHEET C1220" FORCE MAIN, TYP 25'40'25' TEMPORARY CONSTRUCTION EASEMENT, TYP EXISTING 40' EASEMENT, TYP 15'EX 12" FORCE MAIN, TYP SCOTTIE DOUGLAS McFARLAND D.B. 215, PG 458 P.B. 14, PG. 96 P.B. 5A, PG. 65 ADDRESS: 2132 INFINITY ROAD AGNES S. CRIST & ANAV S. MAGDA ESTATE FILE NO. 1989-E-469 P.B. 82, PG. 47 ADDRESS: 2000 SNOW VALLEY ROADSNOW VALLEY RD AGNES S. CRIST & ANAV S. MAGDA ESTATE FILE NO. 1989-E-469 P.B. 82, PG. 47 ADDRESS: 3326 SNOW VALLEY ROAD EXISTING GRADE, TYP 20" PC 350 DIP FORCE MAIN, TYP MIN 3.5' COVER EXISTING GRADE, TYP 20" PC 350 DIP FORCE MAIN, TYP EX ARV MH RIM = 329.0' TOP OF ARV = 327.0'± TOP OF 12" DIP = 323.0'± SILT FENCE, TYP. C-31-0400 LIMITS OF DISTURBANCE, SEE NOTE 2 TREE PROTECTION FENCE, TYP. C-31-0404 NOTES: 1.AFTER THE NEW 20" FORCE MAIN IS IN SERVICE, ABANDON EXISTING ARV MH IN PLACE. RETURN ARV AND VALVES TO THE CITY OF DURHAM. 2.LOD LINE IS NOT SHOWN CONTINUOUSLY FOR CLARITY. THE LIMITS OF DISTURBANCE SHALL BE COINCIDENT WITH THE PROPOSED EASEMENT LIMITS AND PROPOSED TEMPORARY EASEMENT LIMITS WHERE NO LOD IS SHOWN. SEE NOTE 1 TEMPORARY CONSTRUCTION ENTRANCE C-31-0490 305 310 315 320 325 330 305 310 315 320 325 330 70+00 71+00 295 300 305 310 315 320 295 300 305 310 315 320 71+00 72+00 285 290 295 300 305 310 285 290 295 300 305 310 72+00 73+00 275 280 285 290 295 300 275 280 285 290 295 300 73+00 74+00 75+00 260 265 270 275 280 285 260 265 270 275 280 285 75+00 76+00 77+0020" 22.5° BENDSTA 73+9520" 11.25° BENDSTA 76+6720" 22.5° BENDSTA 73+05X XXXXX X X X X X X X3' BARBED WIRE SILT FE N C E 3' BARBED W I R E SILT FENCESILT FENCE SILT FENCE GATE3' B A R B E D W I R E SILT F E N C E ASPHALT SOIL PATH SOIL PATH ARV MANHOLERIM = 329.0'TOP OF ARV = 327.0'+/-TOP OF 12" DIP = 323.0'+/-FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCETCETCETCETCE TCE TCE 70+00 71+00 72+00 73+00 74+00 75+00 76+00 77+ 0 0 32031531030 5 3 0 0 2 9 5 29 0 290 285 28 5 2 8 5 280 295290285275 280280 285300300 325330STA 73+05 20" 22.5° BEND STA 73+95 20" 22.5° BEND SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/ T P F SF/ T P F SF/ T P F TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCETCETCETCETCETCE TCE TPF TPF TPF TPF TPF TPF TPF TPF TPF TPFTPF TPF TPF TPF TPF TPF LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD STA 76+67 20" 11.25° BEND PLOT DATE: 1/19/2021 12:48 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C11 Saved by ENG Save date: 11/12/2020 2:50 PMSNOW HILL ROAD FORCEMAIN 31453-000 01 JANUARY 2021B. PORTER IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 WHARTON-SMITH, INC. 5601 77 CENTER DRIVE #120, CHARLOTTE, NORTH CAROLINA 28217 90% SUBMITTAL - NOT FOR CONSTRUCTION N. JOHNSON E. NG C11 20" FORCE MAIN PLAN AND PROFILE STATION 70+00 TO 77+00 B. PORTER PROFILE H: 1" = 30' V: 1" = 3'MATCHLINE - STA 70+00 SEE SHEET C10MATCHLINE - STA 77+00 SEE SHEET C12SCALE: 1" = 30' PLAN 20" FORCE MAIN, TYP 25'40'25' TEMPORARY CONSTRUCTION EASEMENT, TYP EXISTING 40' EASEMENT, TYP 15'EX 12" FORCE MAIN, TYP EXISTING GRADE, TYP 20" PC 350 DIP FORCE MAIN, TYP MIN 3.5' COVER EXISTING GRADE, TYP 20" PC 350 DIP FORCE MAIN, TYP STATE OF NORTH CAROLINA D.B. 5510, PG. 636 P.B. 91, PG. 47 ADDRESS: 5723 WANDERLUST LANE WAN D E RL U S T L N STATE OF NORTH CAROLINA D.B. 5510, PG. 636 ADDRESS: 5717 WANDERLUST LANE SCOTTIE DOUGLAS McFARLAND D.B. 215, PG. 458 P.B. 14, PG. 96 P.B. 5A, PG. 65 ADDRESS: 2132 INFINITY ROAD SILT FENCE, TYP. C-31-0400 LIMITS OF DISTURBANCE, SEE NOTE 1 FIBER FILTRATION TUBE C-31-0424 TREE PROTECTION FENCE, TYP. C-31-0404 130 LF RESTRAINED JOINT NOTES: 1.LOD LINE IS NOT SHOWN CONTINUOUSLY FOR CLARITY. THE LIMITS OF DISTURBANCE SHALL BE COINCIDENT WITH THE PROPOSED EASEMENT LIMITS AND PROPOSED TEMPORARY EASEMENT LIMITS WHERE NO LOD IS SHOWN. SILT FENCESILT F E N C E SILT FEN C E SOIL PATHSOIL PATHSOIL PATHSOIL PATHSOIL PATH SOIL P A T H 12" DIP BYPASS VALVEMANHOLE & GATE VALVEGATE VALVESMANHOLERIM= 279.7'INVERT IN (S)= 261.4'INV OUT (N)= 261.3'MANHOLERIM= 279.8'INVERT IN (NE)= 261.8'INVERT IN (S)= 261.1'INV OUT (W)= 261.1'ARV MANHOLERIM = 272.3'TOP OF 12" DIP = 262.4'+/-MANHOLE FULL OF WATERCANNOT SEE PIPEARV MANHOLERIM = 272.6'TOP OF ARV = 268.6'+/-TOP OF 30" DIP = 266.3'+/-ARV MANHOLERIM = 275.0'TOP OF ARV = 270.4'+/-TOP OF 12" DIP = 268.3'+/-ARV MANHOLE RIM = 273.2' TOP OF ARV = 2 6 8 . 6 ' + / - TOP OF 12" DI P = 2 6 6 . 0 ' + / - 12" PVC 21 " D I P21" DIP21" DIPFM FM FM FM FM FM RIP-RAPRIP-RAPENO RIVERENO RIVER ENO R IVER FM FMFMFMFM FM FM FM F M F M FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FMSILT FENCESILT F E N C E SILT FEN C E SOIL PATHSOIL PATHSOIL PATHSOIL PATHSOIL PATH SOIL P A T H 12" DIP BYPASS VALVEMANHOLE & GATE VALVEGATE VALVESMANHOLERIM= 279.7'INVERT IN (S)= 261.4'INV OUT (N)= 261.3'MANHOLERIM= 279.8'INVERT IN (NE)= 261.8'INVERT IN (S)= 261.1'INV OUT (W)= 261.1'ARV MANHOLERIM = 272.3'TOP OF 12" DIP = 262.4'+/-MANHOLE FULL OF WATERCANNOT SEE PIPEARV MANHOLERIM = 272.6'TOP OF ARV = 268.6'+/-TOP OF 30" DIP = 266.3'+/-ARV MANHOLERIM = 275.0'TOP OF ARV = 270.4'+/-TOP OF 12" DIP = 268.3'+/-ARV MANHOLE RIM = 273.2' TOP OF ARV = 2 6 8 . 6 ' + / - TOP OF 12" DI P = 2 6 6 . 0 ' + / - 12" PVC 21 " D I P21" DIP21" DIPFM FM FM FM FM FM RIP-RAPRIP-RAPENO RIVERENO RIVER ENO R IVER FM FMFMFMFM FM FM FM F M F M FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FMTCE TCETCETCE TCE 76+00 77+00 78+00 79+00 80+00 81+00 82+00 83+00 84+00 85+00 86+00 87+00 88+00 89+00 90+00 91+00 92+00 93+00 94+00 95+00 96+00 97+00 98+00 99+00 100+00 101+00 102+00 103+00 104+00 105+00 106+00 107+00 108+00 109+00 110+00 111+00 1 1 2 + 0 0 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 76+00 77+00 78+00 79+00 80+00 81+00 82+00 83+00 84+00 85+00 86+00 87+00 88+00 89+00 90+00 91+00 92+00 93+00 94+00 95+00 96+00 97+00 98+00 99+00 100+00 101+00 102+00 103+00 104+00 105+00 106+00 107+00 108+00 109+00 110+00 OVERALL HDD PLAN 1" = 120' N. JOHNSON E. NG C12 HDD OVERALL PLAN & PROFILE B. PORTER STA 78+00 HDD EXIT POINT STA 90+63 START OF HORIZONTAL CURVE STA 93+27 END OF HORIZONTAL CURVE HORIZONTAL CURVE R=1,000' 24" HDPE DR11 FORCEMAIN STA 109+76 HDD ENTRY POINT ENO R IVER ENO RIVERENO R I V ER PLOT DATE: 1/19/2021 12:49 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C12 Saved by ENG Save date: 11/2/2020 8:18 PMSNOW HILL ROAD FORCEMAIN 31453-000 01 JANUARY 2021B. PORTER IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 WHARTON-SMITH, INC. 5601 77 CENTER DRIVE #120, CHARLOTTE, NORTH CAROLINA 28217 90% SUBMITTAL - NOT FOR CONSTRUCTION OVERALL HDD PROFILE 1" = 120' 19.6' 21.5' XSILT F E N C E FM FM FM FM FM FM FM TBM BENCHTIE SET IN 12" CEDAR NAVD '88 ELEV: 280.95'XSILT F E N C E FM FM FM FM FM FM FM TBM BENCHTIE SET IN 12" CEDAR NAVD '88 ELEV: 280.95' TCE TCETCETCETCETCETCE TCE TCETCE TCE 77+00 78+00 79+00 80+00 81+00 82+00 83+00 84+00 2 7 0 295 2 8 5 2802 7 5 290295300260 26 5 285 2903002903002902 8 0 27 0 SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPFSF/TPFSF/TPF SF/TPF SF/TPF SF/TPFTPF TPF TPF TPF TPFTPFTPF TPF TPF ARV MANHOLE RIM = 273.2' TOP OF ARV = 268.6'+/- TOP OF 12" DIP = 266.0'+/-FMFM FM FM FM FM FM FM FMFMFMFMFM FM ARV MANHOLE RIM = 273.2' TOP OF ARV = 268.6'+/- TOP OF 12" DIP = 266.0'+/-FMFM FM FM FM FM FM FM FMFMFMFMFM FM 84+00 85+00 86+00 87+00 88+00 89+00 90+00 91+00 2 7 0 27 0 2 5 5 2 5 5 255255270 270265260 265 265 260 260 26 0 2602652 6 02652 7 0 265 260 255 27 0 2602602 7 0 270PLAN 1" = 30'PLOT DATE: 1/19/2021 12:50 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C13 Saved by ENG Save date: 11/9/2020 4:53 PMSNOW HILL ROAD FORCEMAIN 31453-000 01 JANUARY 2021B. PORTER IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 WHARTON-SMITH, INC. 5601 77 CENTER DRIVE #120, CHARLOTTE, NORTH CAROLINA 28217 90% SUBMITTAL - NOT FOR CONSTRUCTION N. JOHNSON E. NG C13 20" FORCE MAIN PLAN STATION 77+00 TO 91+00 B. PORTERMATCHLINE - STA 77+00 SEE SHEET C12MATCHLINE - STA 84+00 SEE THIS SHEETNOTES: 1.SEE PROFILE ON SHEET C16 AND C17. EN O R I V E R MATCHLINE - STA 84+00 SEE THIS SHEETMATCHLINE - STA 91+00 SEE SHEET C14PROPOSED 30' EASEMENT, TYP EXISTING 40' EASEMENT, TYP ENO RIVER PLAN 1" = 30' PROPOSED 30' EASEMENT, TYP EX 12" FM, TYP EX 30" EMPTY PIPE, TYP STA 78+00 HDD EXIT POINT ENO R IVER STA 90+63 START OF HORIZONTAL CURVE HORIZONTAL CURVE R=1000' SILT FENCE, TYP. C-31-0400 LIMITS OF DISTUBANCE TREE PROTECTION FENCE, TYP. C-31-0404 24" HDPE DR11 FORCE MAIN, TYP 24" HDPE DR11 FORCE MAIN, TYP TBM BENCHTIE SET IN 18" SWEETGUM NAVD '88 ELEV: 273.55' FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM TBM BENCHTIE SET IN 18" SWEETGUM NAVD '88 ELEV: 273.55' FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM91+00 92+00 93+00 94+00 95+00 96+00 97+00 98+00 270270270270 270 TBM BENCHTIE SET IN 18" PINE NAVD '88 ELEV: 272.98' FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM TBM BENCHTIE SET IN 18" PINE NAVD '88 ELEV: 272.98' FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM 98+00 99+00 100+00 101+00 102+00 103+00 104+00 105+00 270 270 2 7 0 2 7 0 270270270270PLAN 1" = 30'PLOT DATE: 1/19/2021 12:51 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C14 Saved by AMARCH Save date: 11/9/2020 11:18 AMSNOW HILL ROAD FORCEMAIN 31453-000 01 JANUARY 2021B. PORTER IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 WHARTON-SMITH, INC. 5601 77 CENTER DRIVE #120, CHARLOTTE, NORTH CAROLINA 28217 90% SUBMITTAL - NOT FOR CONSTRUCTION N. JOHNSON E. NG C14 20" FORCE MAIN PLAN STATION 91+00 TO 105+00 B. PORTERMATCHLINE - STA 91+00 SEE SHEET C13MATCHLINE - STA 98+00 SEE THIS SHEETNOTES: 1.SEE PROFILE ON SHEET C17, C18, AND C19. 24" HDPE DR11 FORCE MAIN, TYP EXISTING 40' EASEMENT, TYP MATCHLINE - STA 99+00 SEE THIS SHEETMATCHLINE - STA 105+00 SEE SHEET C15PLAN 1" = 30' 24" HDPE DR11 FORCE MAIN, TYP PROPOSED 30' EASEMENT EXISTING 40' EASEMENT, TYP EXISTING 12" FM, TYP EXISTING 12" FM, TYP STA 93+27 END OF HORIZONTAL CURVE HORIZONTAL CURVE R=1000' 12" DIP BYPASS VALVEMANHOLE & GATE VALVEGATE VALVESMANHOLERIM= 279.8'INVERT IN (NE)= 261.8'INVERT IN (S)= 261.1'INV OUT (W)= 261.1'12" PVC 21" DIPT B M B E N C H T I E S E T I N 1 6 " P I N E N A V D ' 8 8 E L E V : 2 7 2 . 8 7 ' F M F M F M F M F M FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM12" DIP BYPASS VALVEMANHOLE & GATE VALVEGATE VALVESMANHOLERIM= 279.8'INVERT IN (NE)= 261.8'INVERT IN (S)= 261.1'INV OUT (W)= 261.1'12" PVC 21" DIPT B M B E N C H T I E S E T I N 1 6 " P I N E N A V D ' 8 8 E L E V : 2 7 2 . 8 7 ' F M F M F M F M F M FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM TCETCE105+00 106+00 107+00 108+00 109+00 110+ 0 0 111+ 0 0270270270260 260260265STA 109+73 20" 22.5° BEND STA 111+01 20" 22.5° BEND S F S F S F S F S F / T P FSF/TPFSF/TPFSF/TPFSF/TPFSF/TPFSF/TPF SF/TPF TCETCELODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LODLODL O D L O D L O D L O D L O D L O D L O D L O D L O D260265STA 109+58 3" AIR VACUUM VALVE (FULL SIZED OUTLET) PLAN 1" = 30'PLOT DATE: 1/19/2021 12:52 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C15 Saved by ENG Save date: 11/17/2020 9:01 AMSNOW HILL ROAD FORCEMAIN 31453-000 01 JANUARY 2021B. PORTER IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 WHARTON-SMITH, INC. 5601 77 CENTER DRIVE #120, CHARLOTTE, NORTH CAROLINA 28217 90% SUBMITTAL - NOT FOR CONSTRUCTION N. JOHNSON E. NG C15 20" FORCE MAIN PLAN AND PROFILE STATION 105+00 TO 111+00 B. PORTERMATCHLINE - STA 98+00 SEE SHEET C14MATCHLINE - STA 111+00 SEE SHEET C20NOTES: 1.SEE PROFILE ON SHEET C19. EXISTING 40' EASEMENT, TYP 24" HDPE DR11 FORCE MAIN, TYP PROPOSED 30' EASEMENT, TYP EX 12" FM, TYP EX 30" EMPTY PIPE, TYP PROPOSED TEMPORARY CONSTRUCTION EASEMENT, TYP SILT FENCE, TYP. C-31-0400 LIMITS OF DISTUBANCE TREE PROTECTION FENCE, TYP. C-31-0404 EX 36" FM, TYP STA 109+76 HDD ENTRY POINT 20" FORCE MAIN, TYP 230 235 240 245 250 230 235 240 245 250 80+50 81+00 82+00 83+00 84+00 85+00 86+00 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 77+00 78+00 79+00 80+00 80+503" AIR VACUUM VALVE(FULL SIZED OUTLET)STA 77+25265 270 275 280 285 290 295 300 305 310 265 270 275 280 285 290 295 300 305 310 80+50 81+00 82+00 83+00 84+00 85+00 86+00 PROFILE H: 1" = 40' V: 1" = 4'PLOT DATE: 1/19/2021 12:52 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C16 Saved by ENG Save date: 11/2/2020 9:12 PMSNOW HILL ROAD FORCEMAIN 31453-000 01 JANUARY 2021B. PORTER IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 WHARTON-SMITH, INC. 5601 77 CENTER DRIVE #120, CHARLOTTE, NORTH CAROLINA 28217 90% SUBMITTAL - NOT FOR CONSTRUCTION N. JOHNSON E. NG C16 20" FORCE MAIN PROFILE STATION 77+00 TO 86+00 B. PORTER EX GRADE, TYP MIN 1000' RADIUS, TYP 24" HDPE DR11 FORCEMAIN, TYP EXIT ANGLE TBD BY HDD CONTRACTOR ENO RIVER*253 LF RESTRAINED JOINT 225 230 235 240 245 250 255 260 265 270 275 280 285 225 230 235 240 245 250 255 260 265 270 275 280 285 86+00 87+00 88+00 89+00 90+00 91+00 92+00 93+00 94+00 95+00 PROFILE H: 1" = 40' V: 1" = 4'PLOT DATE: 1/19/2021 12:53 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C17 Saved by ENG Save date: 11/2/2020 9:05 PMSNOW HILL ROAD FORCEMAIN 31453-000 01 JANUARY 2021B. PORTER IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 WHARTON-SMITH, INC. 5601 77 CENTER DRIVE #120, CHARLOTTE, NORTH CAROLINA 28217 90% SUBMITTAL - NOT FOR CONSTRUCTION N. JOHNSON E. NG C17 20" FORCE MAIN PLAN AND PROFILE STATION 86+00 TO 95+00 B. PORTER 24" HDPE DR11 FORCEMAIN, TYP ENO RIVER EX GRADE, TYP EX 12" FM 19.6' 225 230 235 240 245 250 255 260 265 270 275 280 285 225 230 235 240 245 250 255 260 265 270 275 280 285 95+00 96+00 97+00 98+00 99+00 100+00 101+00 102+00 103+00 104+00 PROFILE H: 1" = 40' V: 1" = 4'PLOT DATE: 1/19/2021 12:53 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C18 Saved by ENG Save date: 10/30/2020 8:24 PMSNOW HILL ROAD FORCEMAIN 31453-000 01 JANUARY 2021B. PORTER IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 WHARTON-SMITH, INC. 5601 77 CENTER DRIVE #120, CHARLOTTE, NORTH CAROLINA 28217 90% SUBMITTAL - NOT FOR CONSTRUCTION N. JOHNSON E. NG C18 20" FORCE MAIN PROFILE STATION 95+00 TO 104+00 B. PORTER EX GRADE, TYP 24" HDPE DR11 FORCEMAIN, TYP 225 230 235 240 245 250 255 260 265 270 275 280 285 225 230 235 240 245 250 255 260 265 270 275 280 285 104+00 105+00 106+00 107+00 108+00 109+00 110+00 111+0020" 22.5° BENDSTA 109+7320" 22.5° VERT BENDSTA 110+0720" 22.5° VERT BENDSTA 110+1220" 22.5° VERT BENDSTA 110+3820" 22.5° VERT BENDSTA 110+323" AIR VACUUM VALVE(FULL SIZED OUTLET)STA 109+58PROFILE H: 1" = 40' V: 1" = 4'PLOT DATE: 1/19/2021 12:54 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C19 Saved by ENG Save date: 11/2/2020 9:06 PMSNOW HILL ROAD FORCEMAIN 31453-000 01 JANUARY 2021B. PORTER IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 WHARTON-SMITH, INC. 5601 77 CENTER DRIVE #120, CHARLOTTE, NORTH CAROLINA 28217 90% SUBMITTAL - NOT FOR CONSTRUCTION N. JOHNSON E. NG C19 20" FORCE MAIN PLAN AND PROFILE STATION 104+00 TO 111+00 B. PORTER * EX GRADE, TYP MIN 1000' RADIUS, TYP 24" HDPE DR11 FORCEMAIN, TYP ENTRY ANGLE TBD BY HDD CONTRACTOR EX 12" FM EX 36" FM EX 21" SS 18" MIN 431 LF RESTRAINED JOINTSTA 109+43TRANSITION FROM24" HDPE TO 20" DIP 255 260 265 270 275 280 255 260 265 270 275 280 111+00 112+00 113+00 114+00 115+00 116+00 117+00 118+0020" 22.5° BENDSTA 111+0120" PLUG VALVESTA 112+00SOIL PATH SOIL PATHMANHOLE RIM= 279.1' INVERT IN (E)= 260.6' INV OUT (W)= 260.6' ARV MANHOLE RIM = 276.7' TOP OF ARV = 272.2'+/- TOP OF 12" DIP = 269.6'+/- 21" DIP21" DIP FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM SOIL PATH SOIL PATHMANHOLE RIM= 279.1' INVERT IN (E)= 260.6' INV OUT (W)= 260.6' ARV MANHOLE RIM = 276.7' TOP OF ARV = 272.2'+/- TOP OF 12" DIP = 269.6'+/- 21" DIP21" DIP FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM 111+ 0 0 112+00 113+00 114+00 115+00 116+00 117+00 118+00 2 7 0270 2 7 0 270STA 111+01 20" 22.5° BEND SF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD STA 112+00 20" PLUG VALVE PLAN 1" = 30' PROFILE H: 1" = 30' V: 1" = 3'PLOT DATE: 1/19/2021 12:55 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C20 Saved by ENG Save date: 11/12/2020 4:03 PMSNOW HILL ROAD FORCEMAIN 31453-000 01 JANUARY 2021B. PORTER IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 WHARTON-SMITH, INC. 5601 77 CENTER DRIVE #120, CHARLOTTE, NORTH CAROLINA 28217 90% SUBMITTAL - NOT FOR CONSTRUCTION N. JOHNSON E. NG C20 20" FORCE MAIN PLAN AND PROFILE STATION 111+00 TO 118+00 B. PORTERMATCHLINE - STA 111+00 SEE SHEET C15MATCHLINE - STA 118+00 SEE SHEET C21EX 36" FORCE MAIN, TYP 20" FORCE MAIN, TYP EXISTING GRADE, TYP 20" PC 350 DIP FORCE MAIN, TYP EX 12" FORCE MAIN, TYP MIN 3.5' COVER30'25'EXISTING 30' SANITARY SEWER EASEMENT, TYP EXISTING 25' SANITARY SEWER EASEMENT, TYP SILT FENCE, TYP. C-31-0400 LIMITS OF DISTURBANCE, TYP. FIBER FILTRATION TUBE, TYP. C-31-0424 TREE PROTECTION FENCE, TYP. C-31-0404 431 LF RESTRAINED JOINT NOTES: 1.AFTER THE NEW 20" FORCE MAIN IS IN SERVICE, ABANDON EXISTING ARV MH IN PLACE. RETURN ARV AND VALVES TO THE CITY OF DURHAM. SEE NOTE 1 20" 45° BENDSTA 122+4120" 11.25° BENDSTA 122+61255 260 265 270 275 280 255 260 265 270 275 280 118+00 119+00 120+00 121+00 122+00 123+00 124+00 125+00 SOIL PATH MANHOLE RIM= 279.0' INVERT IN (E)= 260.1' INV OUT (W)= 260.1' 21" DIP FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM 117+00 118+00 119+00 120+00 121+00 270270 SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD GATE GRAVEL MANHOLE RIM= 279.2' INVERT IN (E)= 259.5' INV OUT (NW)= 259.4' 21" DIP TBM BENCHTIE SET IN 18" PINE NAVD '88 ELEV: 272.92'FMFMFMFMFMFMFM FM FM FM FM FM FM FM FM FM FM 121+00122+00123+00 124+00 125+00 STA 122+61 20" 11.25° BEND STA 122+41 20" 45° BEND SF/TPFSF/TPFSF/TPFSF/TPFSF/TPFSF/TPFSF/TPFSF SF SF SF SF SF SF SF SF SF SF SF TPF TPF TPF TPF TPF TPF LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD PLOT DATE: 1/19/2021 12:56 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C21 Saved by ENG Save date: 11/12/2020 4:03 PMSNOW HILL ROAD FORCEMAIN 31453-000 01 JANUARY 2021B. PORTER IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 WHARTON-SMITH, INC. 5601 77 CENTER DRIVE #120, CHARLOTTE, NORTH CAROLINA 28217 90% SUBMITTAL - NOT FOR CONSTRUCTION N. JOHNSON E. NG C21 20" FORCE MAIN PLAN AND PROFILE STATION 118+00 TO 125+00 ----MATCHLINE - STA 121+00 SEE THIS SHEETM A T C H L I N E - S T A 1 2 1 + 0 0 S E E T H I S S H E E TMATCHLINE - STA 118+00 SEE SHEET C20MATCHLINE - STA 125+00 SEE SHEET C2230'25'EXISTING 30' SANITARY SEWER EASEMENT, TYP EXISTING 25' SANITARY SEWER EASEMENT, TYP PLAN 1" = 30' EX 36" FORCE MAIN, TYP 20" FORCE MAIN, TYP EXISTING GRADE, TYP 20" PC 350 DIP FORCE MAIN, TYP EX 12" FORCE MAIN, TYP PLAN 1" = 30' PROFILE H: 1" = 30' V: 1" = 3' WETLAND, TYP MIN 3.5' COVER SILT FENCE, TYP. C-31-0400 LIMITS OF DISTURBANCE, TYP.TREE PROTECTION FENCE, TYP. C-31-0404 74 LF RESTRAINED JOINT EX 36" FORCE MAIN, TYP 255 260 265 270 275 280 255 260 265 270 275 280 125+00 126+00 127+00 128+00 129+00 130+00 131+00 132+00 SOIL PATH INV= 271.1' INV= 271.1'40" DIPVENT MANHOLE RIM= 278.6' INVERT IN (SE)= 258.6' INV OUT (NW)= 258.5' SS MANHOLE RIM= 278.2' INVERT IN (SE)= 258.9' INV OUT (NW)= 258.9' ARV MANHOLE RIM = 278.7' TOP OF ARV = 274.7'+/- BOTTOM OF MANHOLE = 270.1+/- CANNOT SEE PIPE 21" DIP TBM BENCHTIE SET IN 18" PINE NAVD '88 ELEV: 276.61' FM FM FM FM FM FM FM FM SOIL PATH INV= 271.1' INV= 271.1'40" DIPVENT MANHOLE RIM= 278.6' INVERT IN (SE)= 258.6' INV OUT (NW)= 258.5' SS MANHOLE RIM= 278.2' INVERT IN (SE)= 258.9' INV OUT (NW)= 258.9' ARV MANHOLE RIM = 278.7' TOP OF ARV = 274.7'+/- BOTTOM OF MANHOLE = 270.1+/- CANNOT SEE PIPE 21" DIP TBM BENCHTIE SET IN 18" PINE NAVD '88 ELEV: 276.61' FM FM FM FM FM FM FM FM 125+00 126+00 127+00 128+00 129+00 130+00 131+00 132+00 SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF TPF TPF TPF TPF TPF TPF TPF TPF TPF TPF TPFFFTFFTFFT FFT FFT FFT FFT LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD PLAN 1" = 30' PROFILE H: 1" = 30' V: 1" = 3'PLOT DATE: 1/19/2021 12:56 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C22 Saved by ENG Save date: 11/12/2020 4:16 PMSNOW HILL ROAD FORCEMAIN 31453-000 01 JANUARY 2021B. PORTER IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 WHARTON-SMITH, INC. 5601 77 CENTER DRIVE #120, CHARLOTTE, NORTH CAROLINA 28217 90% SUBMITTAL - NOT FOR CONSTRUCTION N. JOHNSON E. NG C22 20" FORCE MAIN PLAN AND PROFILE STATION 125+00 TO 132+00 ----MATCHLINE - STA 125+00 SEE SHEET C21MATCHLINE - STA 132+00 SEE SHEET C23NOTES: 1.AFTER THE NEW 20" FORCE MAIN IS IN SERVICE, EXCAVATE TO THE 12" FORCE MAIN CONNECTION AT THE EXISTING MANHOLE. DISCONNECT THE 12" FORCE MAIN FROM THE MANHOLE, REPAIR THE CONNECTION AT THE MANHOLE, AND PLUG 12" PIPE TO ABANDON THE MAIN. 2.THE LIMITS OF DISTURBANCE SHALL NOT EXCEED 30' IN WIDTH WHILE WITHIN REGULATORY STREAM BUFFERS. EXISTING 30' SANITARY SEWER EASEMENT, TYP EX 36" FORCE MAIN, TYP EXISTING 25' SANITARY SEWER EASEMENT, TYP 20" FORCE MAIN, TYP30'25'WETLAND, TYP EX 12" FORCE MAIN, TYP EXISTING GRADE, TYP 20" PC 350 DIP FORCE MAIN, TYP SILT FENCE, TYP. C-31-0400 LIMITS OF DISTURBANCE, TYP. STREAM CROSSING BYPASS TREE PROTECTION FENCE, TYP. C-31-0404 SEE NOTE 1 STREAM BUFFER, TYP. SEE NOTE 2 FIBER FILTRATION TUBE, TYP. C-35-0700 C-31-0424 255 260 265 270 275 280 255 260 265 270 275 280 132+00 133+00 134+00 135+00 136+00 137+00 138+00 139+0020" 45° BENDSTA 135+5520" 11.25° BENDSTA 135+75SOIL PATH SOIL PATH INVERT IN (SE)= 258.6' INV OUT (NW)= 258.5' 21" DIP SOIL PATH SOIL PATH INVERT IN (SE)= 258.6' INV OUT (NW)= 258.5' 21" DIP 132+00 133+00 134+00 135+00 275 SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF TPF TPF TPF TPF TPF TPF TPF TPF TPF TPF LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD MANHOLE RIM = 279.0' INVERT IN (SE)= 258.3' INV OUT (W)= 258.2' 21" DIP MANHOLE RIM = 279.0' INVERT IN (SE)= 258.3' INV OUT (W)= 258.2' 21" DIP135+00136+00 137+00 138+00 139+00 2 8 0 280 275275 2 7 5 STA 135+75 20" 11.25° BEND STA 135+55 20" 45° BEND SFSFSFSF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SFSFTPFTPF TPF TPF TPF TPF TPF TPF TPF TPF TPF TPF TPF TPF LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD PLAN 1" = 30' PROFILE H: 1" = 30' V: 1" = 3'PLOT DATE: 1/19/2021 12:57 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C23 Saved by ENG Save date: 11/12/2020 4:12 PMSNOW HILL ROAD FORCEMAIN 31453-000 01 JANUARY 2021B. PORTER IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 WHARTON-SMITH, INC. 5601 77 CENTER DRIVE #120, CHARLOTTE, NORTH CAROLINA 28217 90% SUBMITTAL - NOT FOR CONSTRUCTION N. JOHNSON E. NG C23 20" FORCE MAIN PLAN AND PROFILE STATION 132+00 TO 139+00 ----MATCHLINE - STA 132+00 SEE SHEET C22MATCHLINE - STA 139+00 SEE SHEET C2430'25'EXISTING 30' SANITARY SEWER EASEMENT, TYP 20" FORCE MAIN, TYP EXISTING GRADE, TYP 20" PC DIP FORCE MAIN, TYP 20'30'EXISTING 30' SANITARY SEWER EASEMENT, TYP MATCHLINE - STA 135+00 SEE THIS SHEETMATCHLINE - STA 135+00 SEE THIS SHEETPLAN 1" = 30' EXISTING 50' DURHAM WATERLINE & DUKE POWER EASEMENT, TYP 20' PERMANENT EASEMENT, TYP 25' PERMANENT EASEMENT, TYP MIN 3.5' COVER SILT FENCE, TYP. C-31-0400 LIMITS OF DISTURBANCE, TYP. TREE PROTECTION FENCE, TYP. C-31-0404 74 LF RESTRAINED JOINT X X X X X XX X X X X X 6' CH AI N LI N K W/ B A R B E D WI R E GATEGATE 6' CHAIN LINK 6' CHA IN L INKW/ BARBED W IRE GATE SOIL PATH OHE OHE OHE OHE OHE OHE OHE OHE OHE GRAV E L GRAVEL GRAVELGRAVEL GRAVEL METAL TANK METAL TANK INV= 276.7' INV= 275.9' 12" CMP INV= 276.6' INV= 276.1'15" CMP EXISTING STORM MANHOLE RIM = 278.9' INV IN (N/W) = 275.6' INV OUT (N/E) = 275.6'EXISTING STORM MANHOLE RIM = 278.9' INV IN (N/W) = 275.4' INV OUT (N/E) = 275.6' GATE VALVE MANHOLE RIM = 280.5' INV IN (N) = 275.2' (6" DIP) INV IN (S) = 276.2' (4" DIP) INV IN (E) = 257.2' (21" DIP) INV OUT (N)= 257.2' (21" DIP) MANHOLE RIM = 280.2' INVERT IN (E)= 257.8' INV OUT (W)= 257.7' 21" DIP TBM BENCHTIE SET IN 16" MAPLE NAVD '88 ELEV: 278.78' ASP H A L T GRA V E L MANHOLE RIM = 281.3' INVERT IN (S)= 257.2' INV OUT (N)= 257.2' PIPES ARE NOT VISIBLE IN MANHOLE EXISTING STORM MANHOLE NO RIM - OPEN HOLE TOP OF STRUCTURE AT GROUND = 277.8' INV IN (N/W) = 276.2' INV IN (N/E) = 276.1' INV OUT (S/E) = 275.9' GRA V E L PLUG VALVE 18" DIP - BYPASS VALVES 4" PVC APPROX DIRECTION METAL TANK 145+58139+00 140+00 141+00 142+00 143+00 144+00 145+00280 280 280 280 280 280 28 0 2 8 0 280 275 275 275 MH-03 RIM: 279.08 INV IN: 257.23 INV OUT: 257.23 STA 143+21 20" 11.25° BEND STA 143+69 20" 11.25° BEND MH-02 RIM: 278.49 INV IN: 257.65 INV IN: 257.22 INV OUT: 257.45 MH-01 RIM: 277.13 INV IN: 266.72 INV OUT: 257.66 MH-04 RIM: 279.33 INV IN: 257.20 INV OUT: 257.20 SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SFSFSF SF SF SF SF SF SF SF SF TPF TPF TPF TPF TPF TPF TPF TPF LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD STA 143+00 3" AIR VACUUM VALVE (FULL SIZED OUTLET) 255 260 265 270 275 280 285 255 260 265 270 275 280 285 139+00 140+00 141+00 142+00 143+00 144+00 145+00 146+00 147+00 38 LF 48" DIP @ 0.08%58 LF 48" DIP @ 0.38%20" 11.25° BENDSTA 143+2124 LF 48" DIP @ 0.04%3" AIR VACUUM VALVE(FULL SIZED OUTLET)STA 143+0020" 11.25° BENDSTA 143+69MH-03INV IN: 257.23 (48" DIP)INV OUT: 257.23 (48" DIP)STA 145+04RIM: 279.08MH-02INV IN: 257.65 (48" DIP)INV IN: 257.22 (21" DIP)INV OUT: 257.45 (48" DIP)STA 144+47RIM: 278.49MH-01INV IN: 257.86 (20" DIP)INV OUT: 257.66 (48" DIP)STA 144+23RIM: 277.13MH-04INV IN: 257.20 (48" DIP)INV OUT: 257.20 (48" DIP)STA 145+42RIM: 279.33PLOT DATE: 1/19/2021 12:58 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C24 Saved by ENG Save date: 11/12/2020 4:16 PMSNOW HILL ROAD FORCEMAIN 31453-000 01 JANUARY 2021B. PORTER IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 WHARTON-SMITH, INC. 5601 77 CENTER DRIVE #120, CHARLOTTE, NORTH CAROLINA 28217 90% SUBMITTAL - NOT FOR CONSTRUCTION N. JOHNSON E. NG C24 20" FORCE MAIN PLAN AND PROFILE STATION 139+00 TO 146+00 ---- PLAN 1" = 30' PROFILE H: 1" = 30' V: 1" = 3'MATCHLINE - STA 139+00 SEE SHEET C23NOTES: 1.ABANDON EXISTING MANHOLE IN PLACE. 2.EXISTING 36" FORCE MAIN BYPASS PIPE IS AROUND THE EXISTING CONCRETE STRUCTURE, INCLUDING 36" PLUG VALVES. CONTRACTOR SHALL POT HOLE AND LOCATE EXISTING BYPASS PIPING PRIOR TO BEGINNING RELOCATION AND REPLACEMENT OF THE GRAVITY SEWER. 3.LOCATE SOURCE OF 6" DIP AND REDIRECT TO MH-03. OUTSIDE DROP CONNECTION IS REQUIRED. EXISTING GRADE, TYP 20" PC 350 DIP FORCE MAIN, TYP EXISTING 30' SANITARY SEWER EASEMENT, TYP 20' PERMANENT EASEMENT, TYP 36" FORCE MAIN, TYP20'SEE NOTE 1 SILT FENCE, TYP. C-31-0400 LIMITS OF DISTURBANCE, TYP. TREE PROTECTION FENCE, TYP. C-31-0404 36" BYPASS VALVE SEE NOTE 2 SEE NOTE 3 209 LF RESTRAINED JOINT Eno RiverPump Station Snow Hill RoadPump Station Figure 3: Impacts Index MapSnow Hill Road Force MainDurham CountyDurham, North Carolina®1 inch = 1,500 feet 0 1,5005001,000 Feet Legend Index to Im pacts Force Main Alignm ent Limits of Disturbance Stream Wetlan ds Pond Snow Hill RoadI n f i n i t y R o a d E n o R i v e r Cabin Branch Little RiverFigu res 3A and 4A Figu res 3B and 4B Figu res 3C an d 4 C Figu res 3D an d 4 D Figure 3A: Waters of the US Impacts MapSnow Hill Road Force MainDurham CountyDurham, North Carolina®1 inch = 100 feet 0 10050Feet Legend Force Main Alignment Limits of Disturbance Stream Wetlands Snow Hill RoadCabin Branch UT1 to Cabin BranchUT2 t o Cabi n Br anchS1 - Cabin BranchOpen Cut Installation30 Feet of Temporary Impact S2 - UT1 to Cabin BranchOpen Cut Installation98 Feet of Temporary Impact S3 - UT2 to Cabin BranchOpen Cut Installation51 Feet of Temporary Impact Figure 3B: Waters of the US Impacts MapSnow Hill Road Force MainDurham CountyDurham, North Carolina®1 inch = 100 feet 0 10050Feet Legend Force Main Alignment Limits of Disturbance Stream Wetlands Pond Sno w Hill Ro adUT1 to Little River S4 - UT1 to Little RiverOpen Cut Installation30 Feet of Temporary Impact Figure 3C: Waters of the US Impacts MapSnow Hill Road Force MainDurham CountyDurham, North Carolina®1 inch = 100 feet 0 10050Feet Legend Force Main Alignment Limits of Disturbance Stream Wetlands S n o w H ill R o a d UT2 to Little River S5 - UT2 to Little RiverOpen Cut Installation37 Feet of Temporary Impact Figure 3D: Waters of the US Impacts MapSnow Hill Road Force MainDurham CountyDurham, North Carolina®1 inch = 100 feet 0 10050Feet Legend Force Main Alignment Limits of Disturbance Stream Wetlands U T 2 to E n o R iv e rS6 - UT2 to Eno RiverOpen Cut Installation30 Feet of Temporary Impact Eno RiverPump Station Snow Hill RoadPump Station Figure 3: Impacts Index MapSnow Hill Road Force MainDurham CountyDurham, North Carolina®1 inch = 1,500 feet 0 1,5005001,000 Feet Legend Index to Im pacts Force Main Alignm ent Limits of Disturbance Stream Wetlan ds Pond Snow Hill RoadI n f i n i t y R o a d E n o R i v e r Cabin Branch Little RiverFigu res 3A and 4A Figu res 3B and 4B Figu res 3C an d 4 C Figu res 3D an d 4 D Figure 4A: Buffer Impacts MapSnow Hill Road Force MainDurham CountyDurham, North Carolina®1 inch = 100 feet 0 10050Feet Legend Force Main Alignment Limits of Disturbance Permanent Buffer Impact Temporary Buffer Impact Stream Wetlands Zone 1 Buffer Zone 2 Buffer Snow Hill RoadCabin Branch UT1 to Cabin BranchUT2 t o Cabi n Br anchB1 - Cabin Branch - Deemed Allow ablePerpendicular Crossing for N ew Se wer Installa tionPermanent Impact2,787 Square Feet of Zone 1759 Square Feet of Zone 2 B2 - UT1 to Cabin Branch Allowable with MitigationOther than Perpendicular Crossing for New Sewer InstallationPermanent Impact4,823 Square Feet of Zone 1 B4 - UT1 to Cabin Branch Deemed AllowableOther than Perpendicular Crossing for New Sewer InstallationTemporary Impact1,174 Square Feet of Zone 2 B6 - UT2 to Cabin Branch Deemed AllowableOther than Perpendicular Crossing for New Sewer InstallationPermanent Impact852 Square Feet of Zone 2 B7 - UT2 to Cabin Branch Deemed AllowableOther than Perpendicular Crossing for New Sewer InstallationTemporary Impact483 Square Feet of Zone 2 B3 - UT1 to Cabin Branch Allowable with MitigationOther than Perpendicular Crossing for New Sewer InstallationTemporary Impact2,153 Square Feet of Zone 1 B5 - UT1 to Cabin Branch Deemed AllowableOther than Perpendicular Crossing for New Sewer InstallationPermanent Impact581 Square Feet of Zone 2 B8 - UT2 to Cabin Branch Allowable with MitigationOther than Perpendicular Crossing for New Sewer InstallationPermanent Impact380 Square Feet of Zone 1 B9 - UT2 to Cabin Branch Allowable with MitigationOther than Perpendicular Crossing for New Sewer InstallationTemporary Impact2,508 Square Feet of Zone 1 B7 - UT2 to Cabin Branch Deemed AllowableOther than Perpendicular Crossing for New Sewer InstallationTemporary Impact483 Square Feet of Zone 2 Figure 4B: Buffer Impacts MapSnow Hill Road Force MainDurham CountyDurham, North Carolina®1 inch = 100 feet 0 10050Feet Legend Permanent Buffer Impact Temporary Buffer Impact Force Main Alignment Limits of Disturbance Stream Wetlands Pond Zone 1 Buffer Zone 2 Buffer Sno w Hill Ro adUT1 to Little River B11 - UT1 to Little River - Deemed AllowablePerpendicular Crossing for New Sewer InstallationTemporary Impact523 Square Feet of Zone 1498 Square Feet of Zone 2 B10 - UT1 to Little River - Deeme d AllowablePerpendicular Crossing for New Se wer Installa tionPermanent Impact1,893 Square Feet of Zone 11,511 Square Feet of Zone 2 Figure 4C: Buffer Impacts MapSnow Hill Road Force MainDurham CountyDurham, North Carolina®1 inch = 100 feet 0 10050Feet Legend Force Main Alignment Permanent Buffer Impact Temporary Buffer Impact Limits of Disturbance Stream Zone 1 Buffer Zone 2 Buffer S n o w H ill R o a d UT2 to Little River B12 - UT2 to Little River - Deeme d AllowablePerpendicular Crossing for New Se wer Installa tionTemporary Impact815 Square Feet of Zone 2 B13 - UT2 to Little River - Deemed AllowablePerpendicular Crossing for New Sewer InstallationPermanent Impact2,278 Square Feet of Zone 1860 Square Feet of Zone 2 Figure 4D: Buffer Impacts MapSnow Hill Road Force MainDurham CountyDurham, North Carolina®1 inch = 100 feet 0 10050Feet Legend Force Main Alignment Permanent Buffer Impact Temporary Buffer Impact Limits of Disturbance Stream Wetlands Zone 1 Buffer Zone 2 Buffer U T 2 to E n o R iv e rB14 - UT2 to Eno River - Deemed AllowablePerpendicular Crossing for New Sewer InstallationTemporary Impact1,825 Square Feet of Zone 11,216 Square Feet of Zone 2 Snow Hill Road Force Main – diffuse flow discussion Diffuse flow will be maintained throughout the limits of disturbance and the riparian buffer through the use of permanent seeding and planting of native and riparian vegetation, and maintenance of existing drainage patterns throughout the buffered areas. No grading or permanent stormwater measures will be put in place to channelize or concentrate stormwater runoff from the site. The erosion and sediment control measures for the project were designed to meet NC DEQ requirements, including the NC Erosion and Sedimentation Control Planning and Design Manual and the NC Construction General Permit NCG01, as well as Title 15A, Chapter 4 of the NC Administrative Code. The proposed project will not create concentrated stormwater flow through the buffer. Description of Blasting Blasting is necessary to fracture the subsurface rock so that it can be excavated by mechanical means when the pipe laying construction equipment digs the pipe trench. It is confined to the pipe alignment, and blasts are sized and spaced to provide the necessary fracturing while maintaining the fracturing within the work area limits. Generally, a drill rig works ahead of the trench excavation equipment (pipe laying crew), and drills pilot holes until the surface of the rock is located. Then, the rig will drill holes to the depth required through the rock to set the dynamite in the proper location. Typically, the pilot hole drilling is completed for a certain length ahead of the pipe laying crew to map out the rock profile. The drilling and blasting crew returns to drill and set the dynamite. The pre-blast effort can take days or weeks depending on how far ahead of the pipe laying the contractor wants to drill before blasting. Blasting is typically performedin an isolated section where blast mats can be laid on top of the ground surface above the blasting area. Setup for blasting may take several days, and a series of blasts in one location will be performed in one day. The blast locations are dictated by the actual subsurface conditions discovered during pre-drilling of the pipe alignment. IPaC resource list This report is an automatically generated list of species and other resources such as critical habitat (collectively referred to as trust resources) under the U.S. Fish and Wildlife Service's (USFWS) jurisdiction that are known or expected to be on or near the project area referenced below. The list may also include trust resources that occur outside of the project area, but that could potentially be directly or indirectly affected by activities in the project area. However, determining the likelihood and extent of effects a project may have on trust resources typically requires gathering additional site- specific (e.g., vegetation/species surveys) and project-specific (e.g., magnitude and timing of proposed activities) information. Below is a summary of the project information you provided and contact information for the USFWS office(s) with jurisdiction in the defined project area. Please read the introduction to each section that follows (Endangered Species, Migratory Birds, USFWS Facilities, and NWI Wetlands) for additional information applicable to the trust resources addressed in that section. Location Durham County, North Carolina Local office Raleigh Ecological Services Field Office (919) 856-4520 (919) 856-4556 MAILING ADDRESS Post Office Box 33726 Raleigh, NC 27636-3726 PHYSICAL ADDRESS 551 Pylon Drive, Suite F U.S. Fish & Wildlife ServiceIPaCInformation for Planning and Consultation Page 1 of 11IPaC: Explore Location resources 1/19/2021https://ecos.fws.gov/ipac/location/3TCSQCBFF5BFRHPXGLUBLEUIAU/resources Raleigh, NC 27606-1487 Page 2 of 11IPaC: Explore Location resources 1/19/2021https://ecos.fws.gov/ipac/location/3TCSQCBFF5BFRHPXGLUBLEUIAU/resources Endangered species This resource list is for informational purposes only and does not constitute an analysis of project level impacts. The primary information used to generate this list is the known or expected range of each species. Additional areas of influence (AOI) for species are also considered. An AOI includes areas outside of the species range if the species could be indirectly affected by activities in that area (e.g., placing a dam upstream of a fish population even if that fish does not occur at the dam site, may indirectly impact the species by reducing or eliminating water flow downstream). Because species can move, and site conditions can change, the species on this list are not guaranteed to be found on or near the project area. To fully determine any potential effects to species, additional site-specific and project-specific information is often required. Section 7 of the Endangered Species Act requires Federal agencies to "request of the Secretary information whether any species which is listed or proposed to be listed may be present in the area of such proposed action" for any project that is conducted, permitted, funded, or licensed by any Federal agency. A letter from the local office and a species list which fulfills this requirement can only be obtained by requesting an official species list from either the Regulatory Review section in IPaC (see directions below) or from the local field office directly. For project evaluations that require USFWS concurrence/review, please return to the IPaC website and request an official species list by doing the following: 1. Draw the project location and click CONTINUE. 2. Click DEFINE PROJECT. 3. Log in (if directed to do so). 4. Provide a name and description for your project. 5. Click REQUEST SPECIES LIST. Listed species and their critical habitats are managed by the Ecological Services Program of the U.S. Fish and Wildlife Service (USFWS) and the fisheries division of the National Oceanic and Atmospheric Administration (NOAA Fisheries ). Species and critical habitats under the sole responsibility of NOAA Fisheries are not shown on this list. Please contact NOAA Fisheries for species under their jurisdiction. 1. Species listed under the Endangered Species Act are threatened or endangered; IPaC also shows species that are candidates, or proposed, for listing. See the listing status page for more information. IPaC only shows species that are regulated by USFWS (see FAQ). 2.NOAA Fisheries, also known as the National Marine Fisheries Service (NMFS), is an office of the National Oceanic and Atmospheric Administration within the Department of Commerce. The following species are potentially affected by activities in this location: 1 2 Page 3 of 11IPaC: Explore Location resources 1/19/2021https://ecos.fws.gov/ipac/location/3TCSQCBFF5BFRHPXGLUBLEUIAU/resources Amphibians Fishes Clams Flowering Plants NAME STATUS Neuse River Waterdog Necturus lewisi Wherever found There is proposed critical habitat for this species. Your location overlaps the critical habitat. https://ecos.fws.gov/ecp/species/6772 Proposed Threatened NAME STATUS Carolina Madtom Noturus furiosus Wherever found There is proposed critical habitat for this species. Your location overlaps the critical habitat. https://ecos.fws.gov/ecp/species/528 Proposed Endangered NAME STATUS Atlantic Pigtoe Fusconaia masoni Wherever found There is proposed critical habitat for this species. The location of the critical habitat is not available. https://ecos.fws.gov/ecp/species/5164 Proposed Threatened Dwarf Wedgemussel Alasmidonta heterodon Wherever found No critical habitat has been designated for this species. https://ecos.fws.gov/ecp/species/784 Endangered NAME STATUS Michaux's Sumac Rhus michauxii Wherever found No critical habitat has been designated for this species. https://ecos.fws.gov/ecp/species/5217 Endangered Smooth Coneflower Echinacea laevigata Wherever found No critical habitat has been designated for this species. https://ecos.fws.gov/ecp/species/3473 Endangered Page 4 of 11IPaC: Explore Location resources 1/19/2021https://ecos.fws.gov/ipac/location/3TCSQCBFF5BFRHPXGLUBLEUIAU/resources Critical habitats Potential effects to critical habitat(s) in this location must be analyzed along with the endangered species themselves. This location overlaps the critical habitat for the following species: Migratory birds The birds listed below are birds of particular concern either because they occur on the USFWS Birds of Conservation Concern (BCC) list or warrant special attention in your project location. To learn more about the levels of concern for birds on your list and how this list is generated, see the FAQ below. This is not a list of every bird you may find in this location, nor a guarantee that every bird on this list will be found in your project area. To see exact locations of where birders and the general public have sighted birds in and around your project area, visit the E-bird data mapping tool (Tip: enter your location, desired date range and a species on your list). For projects that occur off the Atlantic Coast, additional maps and models detailing the relative occurrence and abundance of bird species on your list are NAME TYPE Carolina Madtom Noturus furiosus https://ecos.fws.gov/ecp/species/528#crithab Proposed Neuse River Waterdog Necturus lewisi https://ecos.fws.gov/ecp/species/6772#crithab Proposed Certain birds are protected under the Migratory Bird Treaty Act and the Bald and Golden Eagle Protection Act . Any person or organization who plans or conducts activities that may result in impacts to migratory birds, eagles, and their habitats should follow appropriate regulations and consider implementing appropriate conservation measures, as described below. 1. The Migratory Birds Treaty Act of 1918. 2. The Bald and Golden Eagle Protection Act of 1940. Additional information can be found using the following links: • Birds of Conservation Concern http://www.fws.gov/birds/management/managed-species/ birds-of-conservation-concern.php • Measures for avoiding and minimizing impacts to birds http://www.fws.gov/birds/management/project-assessment-tools-and-guidance/ conservation-measures.php • Nationwide conservation measures for birds http://www.fws.gov/migratorybirds/pdf/management/nationwidestandardconservationmeasures.pdf 1 2 Page 5 of 11IPaC: Explore Location resources 1/19/2021https://ecos.fws.gov/ipac/location/3TCSQCBFF5BFRHPXGLUBLEUIAU/resources available. Links to additional information about Atlantic Coast birds, and other important information about your migratory bird list, including how to properly interpret and use your migratory bird report, can be found below. For guidance on when to schedule activities or implement avoidance and minimization measures to reduce impacts to migratory birds on your list, click on the PROBABILITY OF PRESENCE SUMMARY at the top of your list to see when these birds are most likely to be present and breeding in your project area. NAME BREEDING SEASON (IF A BREEDING SEASON IS INDICATED FOR A BIRD ON YOUR LIST, THE BIRD MAY BREED IN YOUR PROJECT AREA SOMETIME WITHIN THE TIMEFRAME SPECIFIED, WHICH IS A VERY LIBERAL ESTIMATE OF THE DATES INSIDE WHICH THE BIRD BREEDS ACROSS ITS ENTIRE RANGE. "BREEDS ELSEWHERE" INDICATES THAT THE BIRD DOES NOT LIKELY BREED IN YOUR PROJECT AREA.) Bald Eagle Haliaeetus leucocephalus This is not a Bird of Conservation Concern (BCC) in this area, but warrants attention because of the Eagle Act or for potential susceptibilities in offshore areas from certain types of development or activities. https://ecos.fws.gov/ecp/species/1626 Breeds Sep 1 to Jul 31 Blue-winged Warbler Vermivora pinus This is a Bird of Conservation Concern (BCC) only in particular Bird Conservation Regions (BCRs) in the continental USA Breeds May 1 to Jun 30 Prairie Warbler Dendroica discolor This is a Bird of Conservation Concern (BCC) throughout its range in the continental USA and Alaska. Breeds May 1 to Jul 31 Prothonotary Warbler Protonotaria citrea This is a Bird of Conservation Concern (BCC) throughout its range in the continental USA and Alaska. Breeds Apr 1 to Jul 31 Red-headed Woodpecker Melanerpes erythrocephalus This is a Bird of Conservation Concern (BCC) throughout its range in the continental USA and Alaska. Breeds May 10 to Sep 10 Page 6 of 11IPaC: Explore Location resources 1/19/2021https://ecos.fws.gov/ipac/location/3TCSQCBFF5BFRHPXGLUBLEUIAU/resources Probability of Presence Summary The graphs below provide our best understanding of when birds of concern are most likely to be present in your project area. This information can be used to tailor and schedule your project activities to avoid or minimize impacts to birds. Please make sure you read and understand the FAQ "Proper Interpretation and Use of Your Migratory Bird Report" before using or attempting to interpret this report. Probability of Presence ( ) Each green bar represents the bird's relative probability of presence in the 10km grid cell(s) your project overlaps during a particular week of the year. (A year is represented as 12 4-week months.) A taller bar indicates a higher probability of species presence. The survey effort (see below) can be used to establish a level of confidence in the presence score. One can have higher confidence in the presence score if the corresponding survey effort is also high. How is the probability of presence score calculated? The calculation is done in three steps: 1. The probability of presence for each week is calculated as the number of survey events in the week where the species was detected divided by the total number of survey events for that week. For example, if in week 12 there were 20 survey events and the Spotted Towhee was found in 5 of them, the probability of presence of the Spotted Towhee in week 12 is 0.25. 2. To properly present the pattern of presence across the year, the relative probability of presence is calculated. This is the probability of presence divided by the maximum probability of presence across all weeks. For example, imagine the probability of presence in week 20 for the Spotted Towhee is 0.05, and that the probability of presence at week 12 (0.25) is the maximum of any week of the year. The relative probability of presence on week 12 is 0.25/0.25 = 1; at week 20 it is 0.05/0.25 = 0.2. 3. The relative probability of presence calculated in the previous step undergoes a statistical conversion so that all possible values fall between 0 and 10, inclusive. This is the probability of presence score. To see a bar's probability of presence score, simply hover your mouse cursor over the bar. Breeding Season ( ) Yellow bars denote a very liberal estimate of the time-frame inside which the bird breeds across its entire range. If there are no yellow bars shown for a bird, it does not breed in your project area. Survey Effort ( ) Rusty Blackbird Euphagus carolinus This is a Bird of Conservation Concern (BCC) throughout its range in the continental USA and Alaska. Breeds elsewhere Wood Thrush Hylocichla mustelina This is a Bird of Conservation Concern (BCC) throughout its range in the continental USA and Alaska. Breeds May 10 to Aug 31 Page 7 of 11IPaC: Explore Location resources 1/19/2021https://ecos.fws.gov/ipac/location/3TCSQCBFF5BFRHPXGLUBLEUIAU/resources Vertical black lines superimposed on probability of presence bars indicate the number of surveys performed for that species in the 10km grid cell(s) your project area overlaps. The number of surveys is expressed as a range, for example, 33 to 64 surveys. To see a bar's survey effort range, simply hover your mouse cursor over the bar. No Data ( ) A week is marked as having no data if there were no survey events for that week. Survey Timeframe Surveys from only the last 10 years are used in order to ensure delivery of currently relevant information. The exception to this is areas off the Atlantic coast, where bird returns are based on all years of available data, since data in these areas is currently much more sparse. Tell me more about conservation measures I can implement to avoid or minimize impacts to migratory birds. Nationwide Conservation Measures describes measures that can help avoid and minimize impacts to all birds at any location year round. Implementation of these measures is particularly important when birds are most likely to occur in the project area. When birds may be breeding in the area, identifying the locations of any active nests and avoiding their destruction is a very helpful impact minimization measure. To see when birds are most likely to occur and be breeding in your project area, view the Probability of Presence Summary.Additional measures or permits may be advisable depending on the type of activity you are conducting and the type of infrastructure or bird species present on your project site. What does IPaC use to generate the migratory birds potentially occurring in my specified location? The Migratory Bird Resource List is comprised of USFWS Birds of Conservation Concern (BCC)and other species that may warrant special attention in your project location. The migratory bird list generated for your project is derived from data provided by the Avian Knowledge Network (AKN). The AKN data is based on a growing collection of survey, banding, and citizen science datasets and is queried and filtered to return a list of those birds reported as occurring in the 10km grid cell(s) which your project intersects, and that have been identified as warranting special attention because they are a BCC species in that area, an eagle (Eagle Act requirements may apply), or a species that has a particular vulnerability to offshore activities or development. Again, the Migratory Bird Resource list includes only a subset of birds that may occur in your project area. It is not representative of all birds that may occur in your project area. To get a list of all birds potentially present in your project area, please visit the AKN Phenology Tool. What does IPaC use to generate the probability of presence graphs for the migratory birds potentially occurring in my specified location? The probability of presence graphs associated with your migratory bird list are based on data provided by the Avian Knowledge Network (AKN). This data is derived from a growing collection of survey, banding, and citizen science datasets . Probability of presence data is continuously being updated as new and better information becomes available. To learn more about how the probability of presence graphs are produced and how to interpret them, go the Probability of Presence Summary and then click on the "Tell me about these graphs" link. How do I know if a bird is breeding, wintering, migrating or present year-round in my project area? Page 8 of 11IPaC: Explore Location resources 1/19/2021https://ecos.fws.gov/ipac/location/3TCSQCBFF5BFRHPXGLUBLEUIAU/resources To see what part of a particular bird's range your project area falls within (i.e. breeding, wintering, migrating or year- round), you may refer to the following resources:The Cornell Lab of Ornithology All About Birds Bird Guide, or (if you are unsuccessful in locating the bird of interest there), the Cornell Lab of Ornithology Neotropical Birds guide. If a bird on your migratory bird species list has a breeding season associated with it, if that bird does occur in your project area, there may be nests present at some point within the timeframe specified. If "Breeds elsewhere" is indicated, then the bird likely does not breed in your project area. What are the levels of concern for migratory birds? Migratory birds delivered through IPaC fall into the following distinct categories of concern: 1. "BCC Rangewide" birds are Birds of Conservation Concern (BCC) that are of concern throughout their range anywhere within the USA (including Hawaii, the Pacific Islands, Puerto Rico, and the Virgin Islands); 2. "BCC - BCR" birds are BCCs that are of concern only in particular Bird Conservation Regions (BCRs) in the continental USA; and 3. "Non-BCC - Vulnerable" birds are not BCC species in your project area, but appear on your list either because of the Eagle Act requirements (for eagles) or (for non-eagles) potential susceptibilities in offshore areas from certain types of development or activities (e.g. offshore energy development or longline fishing). Although it is important to try to avoid and minimize impacts to all birds, efforts should be made, in particular, to avoid and minimize impacts to the birds on this list, especially eagles and BCC species of rangewide concern. For more information on conservation measures you can implement to help avoid and minimize migratory bird impacts and requirements for eagles, please see the FAQs for these topics. Details about birds that are potentially affected by offshore projects For additional details about the relative occurrence and abundance of both individual bird species and groups of bird species within your project area off the Atlantic Coast, please visit the Northeast Ocean Data Portal. The Portal also offers data and information about other taxa besides birds that may be helpful to you in your project review. Alternately, you may download the bird model results files underlying the portal maps through the NOAA NCCOS Integrative Statistical Modeling and Predictive Mapping of Marine Bird Distributions and Abundance on the Atlantic Outer Continental Shelf project webpage. Bird tracking data can also provide additional details about occurrence and habitat use throughout the year, including migration. Models relying on survey data may not include this information. For additional information on marine bird tracking data, see the Diving Bird Study and the nanotag studies or contact Caleb Spiegel or Pam Loring. What if I have eagles on my list? If your project has the potential to disturb or kill eagles, you may need to obtain a permit to avoid violating the Eagle Act should such impacts occur. Proper Interpretation and Use of Your Migratory Bird Report The migratory bird list generated is not a list of all birds in your project area, only a subset of birds of priority concern. To learn more about how your list is generated, and see options for identifying what other birds may be in your project area, please see the FAQ "What does IPaC use to generate the migratory birds potentially occurring in my specified location". Please be aware this report provides the "probability of presence" of birds within the 10 km grid cell(s) that overlap your project; not your exact project footprint. On the graphs provided, please also look carefully at the survey effort (indicated by the black vertical bar) and for the existence of the "no data" indicator (a red horizontal bar). A high survey effort is the key component. If the survey effort is high, then the probability of presence score can be viewed as more dependable. In contrast, a low survey effort bar or no data bar means a lack of data and, therefore, a lack of certainty about presence of the species. This list is not perfect; it is simply a starting point for identifying what birds of concern have the potential to be in your project area, when they might be there, and if they might be breeding (which Page 9 of 11IPaC: Explore Location resources 1/19/2021https://ecos.fws.gov/ipac/location/3TCSQCBFF5BFRHPXGLUBLEUIAU/resources means nests might be present). The list helps you know what to look for to confirm presence, and helps guide you in knowing when to implement conservation measures to avoid or minimize potential impacts from your project activities, should presence be confirmed. To learn more about conservation measures, visit the FAQ "Tell me about conservation measures I can implement to avoid or minimize impacts to migratory birds" at the bottom of your migratory bird trust resources page. Facilities National Wildlife Refuge lands Any activity proposed on lands managed by the National Wildlife Refuge system must undergo a 'Compatibility Determination' conducted by the Refuge. Please contact the individual Refuges to discuss any questions or concerns. THERE ARE NO REFUGE LANDS AT THIS LOCATION. Fish hatcheries THERE ARE NO FISH HATCHERIES AT THIS LOCATION. Wetlands in the National Wetlands Inventory Impacts to NWI wetlands and other aquatic habitats may be subject to regulation under Section 404 of the Clean Water Act, or other State/Federal statutes. For more information please contact the Regulatory Program of the local U.S. Army Corps of Engineers District. Please note that the NWI data being shown may be out of date. We are currently working to update our NWI data set. We recommend you verify these results with a site visit to determine the actual extent of wetlands on site. This location overlaps the following wetlands: FRESHWATER FORESTED/SHRUB WETLAND PFO1A PSS1A FRESHWATER POND PUB3Kr RIVERINE R2UBH Page 10 of 11IPaC: Explore Location resources 1/19/2021https://ecos.fws.gov/ipac/location/3TCSQCBFF5BFRHPXGLUBLEUIAU/resources Data limitations The Service's objective of mapping wetlands and deepwater habitats is to produce reconnaissance level information on the location, type and size of these resources. The maps are prepared from the analysis of high altitude imagery. Wetlands are identified based on vegetation, visible hydrology and geography. A margin of error is inherent in the use of imagery; thus, detailed on-the-ground inspection of any particular site may result in revision of the wetland boundaries or classification established through image analysis. The accuracy of image interpretation depends on the quality of the imagery, the experience of the image analysts, the amount and quality of the collateral data and the amount of ground truth verification work conducted. Metadata should be consulted to determine the date of the source imagery used and any mapping problems. Wetlands or other mapped features may have changed since the date of the imagery or field work. There may be occasional differences in polygon boundaries or classifications between the information depicted on the map and the actual conditions on site. Data exclusions Certain wetland habitats are excluded from the National mapping program because of the limitations of aerial imagery as the primary data source used to detect wetlands. These habitats include seagrasses or submerged aquatic vegetation that are found in the intertidal and subtidal zones of estuaries and nearshore coastal waters. Some deepwater reef communities (coral or tuberficid worm reefs) have also been excluded from the inventory. These habitats, because of their depth, go undetected by aerial imagery. Data precautions Federal, state, and local regulatory agencies with jurisdiction over wetlands may define and describe wetlands in a different manner than that used in this inventory. There is no attempt, in either the design or products of this inventory, to define the limits of proprietary jurisdiction of any Federal, state, or local government or to establish the geographical scope of the regulatory programs of government agencies. Persons intending to engage in activities involving modifications within or adjacent to wetland areas should seek the advice of appropriate federal, state, or local agencies concerning specified agency regulatory programs and proprietary jurisdictions that may affect such activities. R4SBC R5UBH A full description for each wetland code can be found at the National Wetlands Inventory website Page 11 of 11IPaC: Explore Location resources 1/19/2021https://ecos.fws.gov/ipac/location/3TCSQCBFF5BFRHPXGLUBLEUIAU/resources NCHPO HPOWEB State of North Carolina DOT, Esri, HERE, Garmin, INCREMENT P, NGA, USGS Local districts & boundaries Local individual resources & centerpoints Local Landmark Local Landmark, Gone Local HD Center Point 1/19/2021 11:17:15 AM 0 0.5 10.25 mi 0 0.8 1.60.4 km 1:36,112 North Carolina State Historic Preservation Office State of North Carolina DOT, Esri, HERE, Garmin, INCREMENT P, NGA, USGS | Esri, HERE | DWR Pre-Fil ing Meeting Req u est Form Contact Name * Contact Email Addre ss * Proje ct Owne r * Proje ct Name * Proje ct County * Owne r Addre ss:* Is this a transportation proje ct?* Type (s) of approv al sought from the DWR: Doe s this proje ct hav e an e xisting proje ct ID#?* Ple ase list all e xisting proje ct ID's associate d with this proje cts.* Do you know the name of the staff me mbe r you would like to re que st a me e ting with? Ple ase giv e a brie f proje ct de scription be low.* Please give a couple of dates you are available for a meeting. Keven Arrance karrance@hazenandsawyer.com City of Durham, Water Management Snow Hill Road Force Main Durham City Durham State / Province / Region NC Postal / Zip Code 27704 Country USA Street Address 1600 Mist Lake Drive Address Line 2 Yes No 401 Water Quality Certification - Regular 401 Water Quality Certification - Express Individual Permit Modification Shoreline Stabilization Yes No 20-241 The project consists of construction of a new sewer force main, connecting the new Snow Hill Road Pump Station (currently under construction) to the existing Eno River Pump Station. The proposed force main extends approximately 2.78 miles. The proposed project generally follows either existing sewer easements or roadway rights-of-way. A stream determination for buffer applicability was conducted on 9/10/2020 for the project. Installation of the proposed force main will be by open cut trenching for the majority of the length. Trenchless installation techniques will be used to install the crossing of the Eno River (mainstem and an oxbow). Ple ase attach the docume ntation you would like to hav e the me e ting about. Signature * Submittal Date 11/4/2020 11/5/2020 11/6/2020 11/23/2020 11/24/2020 SHRFM_topo_prefiling mtg map.pdf 615.43KB pdf only By digitally signing below, I certify that I have read and understood that per the Federal Clean Water Act Section 401 Certification Rule the following statements: · This form completes the requirement of the Pre-Filing Meeting Request in the Clean Water Act Section 401 Certification Rule. · I understand by signing this form that I cannot submit my application until 30 calendar days after this pre-filing meeting request. · I also understand that DWR is not required to respond or grant the meeting request. Your project’s thirty-day clock started upon receipt of this application.  You will receive notification regarding meeting location and time if a meeting is necessary.  You will receive notification when the thirty-day clock has expired, and you can submit an application. 11/2/2020