HomeMy WebLinkAbout20201650 Ver 1_ePCN Application_20210314DWR
Division of Water Resources
Pre -Construction Notification (PCN) Form
October 26, 2020 Ver 3.3
Initial Review
Has this project met the requirements for acceptance in to the review process?*
r Yes
r No
Is this project a public transportation project?*
C Yes r No
Change only if needed.
BIMS # Assigned
20201650
Is a payment required for this project?*
r No payment required
r Fee received
r Fee needed - send electronic notification
Reviewing Office *
Central Office - (919) 707-9000
Information for Initial Review
1a. Name of project:
Snow Hill Road Force Main
1a. Who is the Primary Contact?*
Keven Arrance
1b. Primary Contact Email:*
karrance@hazenandsawyer.com
Date Submitted
3/14/2021
Nearest Body of Water
Eno River
Basin
Neuse
Water Classification
WS-N; NSW
Site Coordinates
Latitude: Longitude:
36.076391-78.869788
Pre -Filing Meeting Information
ID#
20201650
Pre -fling Meeting or Request Date*
11/2/2020
Attach documentation of Pre -Filing Meeting Request here:*
DWR Pre -Filing Meeting Request Form.pdf
Version#*
1
What amout is owed?*
r $240.00
r $570.00
Select Project Reviewer*
Rick Trone:eads\rvtrone
1c. Primary Contact Phone:*
(919)522-4269
Version
1
51.39KB
A. Processing Information C^U
County (or Counties) where the project is located:
Durham
Is this a NCDMS Project
r Yes r No
Is this project a public transportation project?*
r Yes r No
la. Type(s) of approval sought from the Corps:
W Section 404 Permit (wetlands, streams and waters, Clean Water Act)
r Section 10 Permit (navigable waters, tidal waters, Rivers and Harbors Act)
Has this PCN previously been submitted?*
r Yes
r No
1b. What type(s) of permit(s) do you wish to seek authorization?
W Nationwide Permit (NWP)
r Regional General Permit (RGP)
r Standard (IP)
1c. Has the NWP or GP number been verified by the Corps?
r Yes r No
Nationwide Permit (NWP) Number:
NWP Numbers (for multiple NWPS):
NWP 58
1d. Type(s) of approval sought from the DWR:
W 401 Water Quality Certification - Regular
r Non-404 Jurisdictional General Permit
r Individual Permit
le. Is this notification solely for the record because written approval is not required?
For the record only for DWR401 Certification:
For the record only for Corps Permit:
r 401 Water Quality Certification - E)press
V Riparian Buffer Authorization
1f. Is this an after -the -fact permit application?*
r Yes r No
1g. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts?
r Yes r No
1g. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts?
r Yes r No
Acceptance Letter Attachment
Buffer SOA - Snow Hill Road Force Main.pdf
1h. Is the project located in any of NC's twenty coastal counties?
r Yes r No
1j. Is the project located in a designated trout watershed?
r Yes r No
B. Applicant Information
1d. Who is applying for the permit?
r Owner W Applicant (other than owner)
le. Is there an Agent/Consultant for this project?*
r Yes r No
2. Owner Information
2a. Name(s) on recorded deed:
City of Durham
2b. Deed book and page no.:
utility easement
2c. Responsible party:
Donald Greeley
2d.Address
119.63KB
*
r Yes r No
r Yes r No
Street Address
1600 Mist Lake Drive
Address tine 2
city
Durham
Postal / Zip Code
27704
2e. Telephone Number:
(919)560-4381
2g. Email Address:*
Donald. F.Greeley@durhamnc.gov
3. Applicant Information (if different from owner)
3a. Name:
Vincent Chirichella, Jr., P.E., Sr. Project Manager
3b. Business Name:
Durham County
3c.Address
Street Address
5926 Highway 55 East
Address tine 2
city
Durham
Postal / Zip Code
27713
3d. Telephone Number:
(919)560-9039
3f. Email Address:*
vchiricheIla@dconc.gov
4. Agent/Consultant (if applicable)
4a. Name:
Keven Arrance
4b. Business Name:
Hazen and Sawyer
4c.Address
Street Address
4011 WestChase Boulevard, Suite 500
Address Line 2
City
Raleigh
Postal / Zip Code
27607
4d. Telephone Number:
(919)522-4269
0. Email Address:*
karrance@hazenandsawyer.com
Agent Authorization Letter*
Agent Auth signed_ VChirichella202l.pdf
C. Project Information and Prior Project History
1. Project Information
1b. Subdivision name:
(i appropriate)
1c. Nearest municipality/ town:
Durham
2. Project Identification
State / Rovince / Rion
NC
Country
USA
2f. Fax Number:
Slate / Rwince / Region
NC
Country
USA
3e. Fax Number:
State / Rmime / Region
NC
Country
USA
4e. Fax Number:
43.33KB
2a. Property Identification Number:
n/a
2b. Property size:
12.3
2c. Project Address
Street Address
begins at 2525 Snow Hill Road
Address Line 2
City
Durham
Postal / Zip Code
27712
3. Surface Waters
3a. Name of the nearest body of water to proposed project:*
Eno River
3b. Water Resources Classification of nearest receiving water:*
WS-N; NSW
3c. What river basin(s) is your project located in?*
Neuse
3d. Please provide the 12-digit HUC in which the project is located.
030202010304
4. Project Description and History
State / Province / Region
NC
Country
USA
4a. Describe the existing conditions on the site and the general land use in the vicinity of the project at the time of this application:*
The project generally follows maintained roadway rights -of -way and maintained utility easements. The corridor is abutted by undeveloped forested areas, rural residential properties, an
institution, agricultural lands, and an active quarry. The proposed project connects to an existing pump station at the downstream end and to a pump station that is currently under
construction at the upstream end.
4b. Have Corps permits or DWR certifications been obtained for this project (including all prior phases) in the past?*
r Yes r No r Unknown
4d. Attach an 8 1/2 X 11 excerpt from the most recent version of the USGS topographic map indicating the location of the project site. (for DWR)
PCN SHRFM_topo.pdf
396.72KB
4e. Attach an 8 1/2 X 11 excerpt from the most recent version of the published County NRCS Soil Survey map depicting the project site. (for DWR)
Detailed Soil Map; Soil Survey of Durham County, North Carolina - map13_2.pdf 689.55KB
Detailed Soil Map; Soil Survey of Durham County, North Carolina - map14_2.pdf 690.4KB
4f. List the total estimated acreage of all existing wetlands on the property:
0.40
4g. List the total estimated linear feet of all existing streams on the property:
3375
4h. Explain the purpose of the proposed project:*
The existing force main is a 12-inch diameter pipe that conveys wastewater from the existing Snow Hill Road Pump Station to a 21-inch diameter gravity sewer, which carries the
wastewater to the Eno River Pump Station. The Snow Hill Road Pump Station is being replaced under a separate project (SAW-2020-00987 and DWR #20-0727), and the existing 12-
inch force main does not have the capacity to hydraulically accommodate future peak flow rates from the new Snow Hill Road Pump Station. The proposed 20-inch Snow Hill Road Force
Main will convey flows to a proposed new segment of gravity sewer at the Eno River Pump Station. The new segment of gravity sewer will replace the downstream most segment of the
existing, 21-inch influent sewer and will tie into the existing 48-inch influent gravity sewer.
41. Describe the overall project in detail, including indirect impacts and the type of equipment to be used:*
The project consists of installation of approximately 14,423 feet of 20-inch sewer force main and 120 feet of 48-inch gravity sewer. The force main and gravity sewer will be ductile iron
pipe. The force main pipe will extend from an existing fitting in the sewer collection network located at 2525 Snow Hill Road to a new manhole (MH-1) adjacent to the Eno River Pump
Station. The proposed force main will parallel the existing force main, which will be abandoned once the proposed pipe is put into service. The pipe corridor parallels the west side of the
right-of-way associated with Snow Hill Road, heading south to just southeast of the eastern terminus of Infinity Road. The pipe corridor then turns to the southwest, following the existing
utility easement toward the Eno River. The proposed pipe will cross the Eno River, traverse an undeveloped island, and cross an oxbowconnected to the Eno River. The river, island,
and oxbow crossings Will be installed via a trenchless technique, specifically horizontal directional drilling. The pipe corridor follows the existing sewer easement to the west, then north-
northwest, then west to MH-1 adjacent to the Eno River Pump Station. The gravity sewer will begin at manhole MH-1 and extend to an existing manhole (MH-4) that is proposed to be
replaced. From MH-4, the existing gravity sewer Will convey the wastewater into the Eno River Pump Station.
From MH-1 to the end of the existing 21-inch diameter gravity sewer, the existing gravity line will be removed. The proposed 48-inch gravity sewer, extending from MH-1 to MH-4, Will
provide conveyance of flows currently carried by the gravity sewer segment to be demolished. To accomplish the connections and turns required along the 48-inch gravity line, a total of
four manholes Will be installed.
The pipe will be installed via open cut trench for the majority of its length. The crossing of Infinity Road Will be installed by jack and bore. Horizontal directional drilling will be the method
of installation under the Eno River and an oxbow of the Eno River. The pipe Will also be horizontally directionally drilled across the island located between the Eno River and its oxbow.
The proposed sewer pipe crosses eight streams, including Cabin Branch, the Eno River, the Eno River oxbow, an unnamed tributary (UT) to the Eno River, two UTs to Little River, and
two UTs to Cabin Branch. Temporary impacts to six of the streams are proposed to result from the open -cut installation of the new force main. The stream crossings will be performed
under dry conditions, using a cofferdam and temporary pump -around system to establish and maintain the dry work area. Once the streambed and banks are restored to their pre -
construction grade and elevation and stabilized, the temporary pump -around system and cofferdams will be removed, allowing the stream flowto return to its natural course. The pipe
corridor is in proximity to two jurisdictional wetland areas and one pond. The wetlands and the pond Will not be impacted by construction of the proposed project.
A variety of construction equipment is anticipated to be used due to the various construction techniques for the project. A horizontal directional drill rig and associated equipment,
reamers, HOPE pipe rollers, cranes, jack and bore machine, backhoes, trackhoes, excavators, shoring equipment, land clearing equipment, and welders are expected to be used.
Additionally, grout pumps, temporary stream bypass pumps, generators, and dump trucks are expected to be utilized. Other construction equipment may be utilized at the discretion of
the contractor.
4j. Please upload project drawings for the proposed project.
31453-000 - Forcemain.pdf
5. Jurisdictional Determinations
5a. Have the wetlands or streams been delineated on the property or proposed impact areas?*
r Yes r No
Comments:
5b. If the Corps made a jurisdictional determination, what type of determination was made?*
r Preliminary r Approved r Not Verified f^ Unknown r N/A
Corps AID Number:
5c. If 5a is yes, who delineated the jurisdictional areas?
Name (if known): K. Arrance, L. Diebolt
Agency/Consultant Company: Hazen and Sawyer
Other:
5d1. Jurisdictional determination upload
6. Future Project Plans
10.68MB
r Unknown
6a. Is this a phased project?*
r Yes r No
Are any other NWP(s), regional general permit(s), or individual permits(s) used, or intended to be used, to authorize any part of the proposed project or related activity?
No.
D. Proposed Impacts Inventory
1. Impacts Summary
1a. Where are the impacts associated with your project? (check all that apply):
r Wetlands W Streams -tributaries W Buffers
r Open Waters r Pond Construction
3. Stream Impacts
3a. Reason for impact (?)
3b.lmpact type *
3c. Type of impact*
3d. S. name*
3e. Stream Type*
Type of
3gSwidth *
3h. Impact(?)
❑
�[3f.
urisdiction*
length*
81
Pipe installation
Temporary
Excavation
Fb�nBranch
Perennial
Corps
20
30
Average (feet)
(linearfeet)
g2
Pipe installation
Temporary
Excavation
UT1 to Cabin Branch
Intermittent
Corps
6
98
Average (feet)
(lirearfeet)
S3
Pipe installation
Temporary
Excavation
UT2 to Cabin Branch
Intermittent
Corps
3
51
Average (feet)
(linearfeet)
S4
Pipe installation
P
Tem orar
P Y
Excavation
UT1 to Little River
Intermittent
Cor P s
5
30
Average (feet)
(lirearfeet)
S5
Pipe installation
Temporary
Excavation
UT2 to Little River
Intermittent
Corps
7
37
Average (feet)
(linearfeet)
H
Pipe installation
Temporary
Excavation
UT1 to Eno River
Intermittent
Corps
6
30
Average (feet)
(linearfee[)
31. Total jurisdictional ditch impact in square feet:
0
31. Total permanent stream impacts:
0
31. Total stream and ditch impacts:
276
3j. Comments:
31. Total temporary stream impacts:
276
6. Buffer Impacts (for DWR)
6a. Project is in which protect basin(s)?
Check all that apply.
V Neuse
F Catawba
F Goose Creek
r Other
r Tar -Pamlico
r Randleman
r Jordan Lake
6b. Impact Type 11
6c. Per or Temp
6d. Stream name
6e. Buffer mitigation required?
6f. Zone 1 impact
6g. Zone 2 impact
B1 - deemed allowable
P
Cabin Branch
No
2,787
759
B2 - allowable with mitigation
P
LF1 to Cabin Branch
Yes
4,823
0
B3 - allowable with mitigation
T
LF1 to Cabin Branch
No
2,153
0
64 - deemed allowable
T
LF1 to Cabin Branch
No
0
1,174
B5 - deemed allowable
P
LF1 to Cabin Branch
No
0
581
66 - deemed allowable
P
LIT2 to Cabin Branch
No
0
852
67 - deemed allowable
T
LIT2 to Cabin Branch
No
0
483
B8 - allowable with mitigation
P
LIT2 to Cabin Branch
Yes
380
0
B9 - allowable with mitigation
T
LIT2 to Cabin Branch
No
2,508
0
B10 - deemed allowable
P
tJT1 to Little River
No
1,893
1,511
1311 -deemed allowable
T
tJT1 to Little River
No
523
498
B12 - deemed allowable
T
LIT2 to Little River
No
0
815
B13 - deemed allowable
P
LIT2 to Little River
No
2,278
860
B14 - deemed allowable
T
tJT2 to Eno River
No
1,825
1,216
6h. Total buffer impacts:
Zone 1 Zone 2
Total Temporary impacts: 7,009.00 4,186.00
Zone 1
Zone 2
Total Permanent impacts: 12,161.00
4,563.00
Zone 1
Zone 2
Total combined buffer impacts: 19,170.00
8,749.00
6i. Comments:
Supporting Documentation
PCN SHRFM_impacts_WOTUS_all.pdf
PCN SHRFM_impacts _Buffers _all.pdf
E. Impact Justification and Mitigation
1. Avoidance and Minimization
2.5MB
2.49MB
1a. Specifically describe measures taken to avoid or minimize the proposed impacts in designing the project:
u
Impacts to jurisdictional areas can only be fully avoided by a no -build alternative, which does not meet the purpose and need for the project. Extensive
efforts to minimize impacts to jurisdictional areas have been made during the development of the project design. The proposed force main follows an
existing force main parallel to an existing NCDOT road and in both existing and proposed easement. Designing the pipe along an already maintained
corridor minimizes new impacts to streams as they are already being maintained. In locations where new easement is required due to space limitations
inside the existing easement, the new force main is designed to be installed as close to the existing easement as possible in order to minimize the new
easement width.
Wetland and open water impacts have been fully avoided by modifications to the alignment and the width of disturbance in areas near these features.
The limits of disturbance have been reduced in width within streams and riparian buffer areas. Permanently maintained corridors will be retained in
perpetuity to accommodate future operations and maintenance needs and provide access for emergency response. Where feasible, the maintained
corridor for the proposed force main will coincide with currently maintained corridors. The proposed new maintained corridors have been reduced in
width within stream buffer areas. The maintained corridors will be seeded with native grasses. The portions of the construction corridor that are
beyond the maintained corridor will be allowed to revegetate naturally from local seed stock.
Relocating the pipe to the east side of Snow Hill Road may offer an opportunity to further reduce the impacts to UT1 to Cabin Branch. However, this
alignment modification was eliminated from consideration due to the presence of an existing natural gas pipeline parallel to the east side of Snow Hill
Road in this area. The measures necessary to avoid conflicts with the natural gas pipeline would result in significantly greater private property
impacts, tree removals, and risks during construction.
Crossings of streams and riparian buffer areas have been designed to be within 15 degrees of perpendicular to the extent practicable. One stream
crossing (S3 — UT2 to Cabin Branch) is not practicable to be achieved at a near -perpendicular angle. Crossing Lfr2 to Cabin Branch at a near -
perpendicular angle would necessitate disturbance of approximately 3,275 square feet of forested buffer that will not be disturbed as a result of the
proposed design. The design keeps the buffer disturbance almost entirely in areas that are currently maintained as part of the roadway right-of-way,
overhead electric easement, and buried utility easement. The impacts to the buffer associated with the UT2 to Cabin Branch crossing will consist of
temporary disturbance of maintained grassy areas that will be restored to pre -construction conditions upon installation of the force main.
1b. Specifically describe measures taken to avoid or minimize the proposed impacts through construction techniques:
The erosion and sediment control measures specified in the design will be installed prior to initiation of land disturbance. Regular inspections of the
erosion and sediment control devices Will be performed, and any necessary repairs or modifications to the devices will be addressed in a timely
manner to ensure that they are maintained in good working order throughout the construction period. Erosion and sediment control devices shall
include silt fencing, fiber filtration tubes and channel lining for drainage swales and roadside ditches, stabilized construction entrances, and temporary
stabilization of disturbed soils and sediments. Excavations will be backfilled and restored on a daily basis to protect against erosion of disturbed soils.
Installation methods were evaluated for each stream crossing associated with the proposed design. Where practicable, trenchless techniques wall be
utilized to avoid impacts to streams and buffers. Horizontal directional drilling Will be performed for the Eno River and Eno River oxbow installation.
Trenchless techniques were determined to be infeasible options at the remaining six stream and buffer crossings.
In -stream construction Will be performed in the dry. Temporary cofferdams and pump -around system will be utilized to establish and maintain dry
conditions within the work area. Stream water discharged from the pump will pass through a filter bag or other device intended to remove excess
sediments from the water prior to returning to the stream channel downstream of the work area.
Construction support activities Will be performed away from surface waters, riparian buffers, and other sensitive resources. Vehicle and equipment
maintenance Will be performed in upland areas to protect against unintentional spills or leaks reaching sensitive ecological areas. Staging of
equipment and materials will be sited in upland areas along the project construction corridor.
2. Compensatory Mitigation for Impacts to Waters of the U.S. or Waters of the State
2a. Does the project require Compensatory Mitigation for impacts to Waters of the U.S. or Waters of the State?
r Yes
r No
2b. If this project DOES NOT require Compensatory Mitigation, explain why:
Impacts to waters of the US are temporary and do not require compensatory mitigation.
F. Stormwater Management and Diffuse Flow Plan (required by DWR)
1. Diffuse Flow Plan
1a. Does the project include or is it adjacent to protected riparian buffers identified within one of the NC Riparian Buffer Protection Rules?
r Yes
r No
What type of SCM are you providing?
r Level Spreader
r Vegetated Conveyance (lower SHWT)
r Wetland Swale (higher SHWT)
r Other SCM that removes minimum 30 % nitrogen
W Proposed project will not create concentrated stormv✓ater flow through the buffer
Diffuse Flow Documentation
PCN Diffuse Flow SHRFM.pdf
2. Stormwater Management Plan
2a. Is this a NCDOT project subject to compliance with NCDOT's Individual NPDES permit NCS000250?*
r Yes r No
2b. Does this project meet the requirements for low density projects as defined in 15A NCAC 02H .1003(2)?
r Yes r No
Comments:
G. Supplementary Information
44.64KB
u
1. Environmental Documentation
1a. Does the project involve an expenditure of public (federal/state/local) funds or the use of public (federal/state) land?*
r Yes r No
1b. If you answered "yes" to the above, does the project require preparation of an environmental document pursuant to the requirements of the National or State (North Carolina)
Environmental Policy Act (NEPA/SEPA)?*
r Yes r No
Comments:
Project does not meet the minimum requirements that trigger a NEPA or SEPA review.
2. Violations (DWR Requirement)
2a. Is the site in violation of DWR Water Quality Certification Rules (15A NCAC 2H .0500), Isolated Wetland Rules (15A NCAC 2H .1300), or DWR Surface Water or Wetland Standards or
Riparian Buffer Rules (15A NCAC 2B .0200)? *
r Yes r No
3. Cumulative Impacts (DWR Requirement)
3a. Will this project result in additional development, which could impact nearby downstream water quality?*
r Yes r No
3b. If you answered "no," provide a short narrative description.
The project will not induce additional development. The project eliminates an existing capacity reduction in a downstream segment of the existing
sewer collection system, allowing the downstream segment to convey the same capacity as the upstream segments that feed into it.
4. Sewage Disposal (DWR Requirement)
4a. Is sewage disposal required by DWR for this project?*
r Yes r Nor WA
5. Endangered Species and Designated Critical Habitat (Corps Requirement)
5a. Will this project occur in or near an area with federally protected species or habitat?*
r Yes r No
5b. Have you checked with the USFWS concerning Endangered Species Act impacts?*
r Yes r No
5d. Is another Federal agency involved?*
r Yes r No r Unknown
5e. Is this a DOT project located within Division's 1-8?
r Yes r No
5f. Will you cut any trees in order to conduct the work in waters of the U.S.?
r Yes r No
5g. Does this project involve bridge maintenance or removal?
r Yes r No
5h. Does this project involve the construction/installation of a wind turbine(s)?*
r Yes r No
5i. Does this project involve (1) blasting, and/or (2) other percussive activities that will be conducted by machines, such as jackhammers, mechanized pile drivers, etc.?
r Yes r No
If yes, please provide details to include type of percussive activity, purpose, duration, and specific location of this activity on the property.
SHRFM - blasting description.pdf
76.01 KB
5j. What data sources did you use to determine whether your site would impact Endangered Species or Designated Critical Habitat?
The IPaC tool was utilized to identify the federally protected species that may occur in the project vicinity. IPaC identified three species proposed for
listing, three endangered species, and two proposed critical habitat areas. The endangered species include dwarf wedgemussel (DWM), Michaux's
sumac, and smooth coneflower. DWM's inclusion on the list is associated with the Eno River. The Eno River and its oxbow will be traversed via
trenchless technique, thereby avoiding impacts to the waterways, their habitats, and water quality in the waterways. Michaux(s sumac and smooth
coneflower inhabit disturbed areas and edges of forested areas that occur on circumneutral to basic soils. The soils required for the endangered
plants are not mapped within the project area. Hazen biologists performed visual assessments of the project area during onsite investigations in June
2020 and observed no individuals of the two species.
Designated critical habitat has been proposed for two species that are proposed for listing - Carolina madtom and %use River waterdog. The
proposed critical habitat for Carolina madtom and for Meuse River waterdog within the project area is within the Eno River, which will be crossed by a
trenchless technique and thereby not impacted by the proposed project.
Consultation Documentation Upload
IPaC_20210119.pdf 392.02KB
6. Essential Fish Habitat (Corps Requirement)
6a. Will this project occur in or near an area designated as an Essential Fish Habitat?*
r Yes R No
6b. What data sources did you use to determine whether your site would impact an Essential Fish Habitat?*
Review of online interactive EFH mapper via NOAA website.
7. Historic or Prehistoric Cultural Resources (Corps Requirement)
7a. Will this project occur in or near an area that the state, federal or tribal governments have designated as having historic or cultural preservation status?*
r Yes r No
7b. What data sources did you use to determine whether your site would impact historic or archeological resources?*
HPOWEB was reviewed most recently on January 19, 2021. Two properties are identified as having a structure that has been surveyed only. The
project involves temporary excavation for installation of a sewer line adjacent to an existing buried sewer line. Any archaeological resources that may
remain within the proposed excavation footprint will be returned to the trench as backfill.
7c. Historic or Prehistoric Information Upload
HPOWEB_20210119.pdf 297.31 KB
8. Flood Zone Designation (Corps Requirement)
8a. Will this project occur in a FEMA-designated 100-year floodplain?*
r Yes r No
8b. If yes, explain how project meets FEMA requirements:
The project design minimizes disturbance within the 100-year floodplain to the minimum necessary to accomplish the pipeline installation. Design
elements have been included in the erosion and sediment control plan to prevent off -site erosion and to mitigate it when unavoidable. A floodplain
development permit will be obtained from the City of Durham prior to initiation of construction.
8c. What source(s) did you use to make the floodplain determination?*
FEMA FIRMS 3720083500K, 3720084400K, and 3720083400K; all effective 10/19/2018
Miscellaneous C^U
Comments
Miscellaneous attachments not previously requested.
Snow Hill Rd Force Main Buffer Determination Letter.pdf 1.67MB
PCN SHRFM_aerial vicinity.pdf 620.81 KB
Signature
W By checking the box and signing below, I certify that:
• The project proponent hereby certifies that all information contained herein is true, accurate, and complete to the best of my knowledge and belief; and
• The project proponent hereby requests that the certifying authority review and take action on this CWA 401 certification request within the applicable reasonable period of time.
• I have given true, accurate, and complete information on this form;
• I agree that submission of this PCN form is a "transaction" subject to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act");
• I agree to conduct this transaction by electronic means pursuant to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act');
• I understand that an electronic signature has the same legal effect and can be enforced in the same way as a written signature; AND
• I intend to electronically sign and submit the PCN form.
Full Name:
Keven Arrance
Signature
Date
3/14/2021
u
EBX Buffer Mitigation Banks
Statement of Availability January 21, 2021
NC Division of Water Resources
Stephanie Goss
512 N. Salisbury St.
Archdale Building, 9th floor
Raleigh, NC 27604
Re Project: Snow Hill Road Force Main
This document confirms that Durham County (Applicant) for the Snow Hill Road Force Main (Project)
has expressed an interest to utilize 15,609.00 Square Feet of Riparian Buffer Mitigation Credits from
the EBX sponsored Upper Neuse Riparian Buffer Umbrella Mitigation Bank or EBX-Neuse I, LLC
sponsored Bucher Mitigation Bank. The specific bank site to be debited will either be Cedar Grove,
Hatley or Bucher all located in HUC 03020201 and in the Falls Lake watershed. As the official Bank
Sponsor, EBX and EBX-Neuse I, LLC, attests to the fact that mitigation is available for reservation at this
time.
These mitigation credits are not considered secured, and consequently are eligible to be used for alternate
purposes by the Bank Sponsor, until payment in full is received from the Applicant resulting in the
issuance of a Mitigation Credit Transfer Certificate by the bank acknowledging that the Applicant has
fully secured credits from the bank and the Banker has accepted full responsibility for the mitigation
obligation requiring the credits/units.
The Banker will issue the Mitigation Credit Transfer Certificate within three (3) days of receipt of the
purchase price. Banker shall provide to Applicant a copy of the Mitigation Credit Transfer Certificate and
a documented copy of the debit of credits from the Bank Official Credit Ledger(s), indicating the permit
number and the resource type secured by the applicant. A copy of the Mitigation Credit Transfer
Certificate, with an updated Official Credit Ledger will also be sent to regulatory agencies showing the
proper documentation.
Please contact me at 919-209-1075 or cparker@res.us if you have any questions or need additional
information.
Best Regards,
Caitlan B. Parker
Resource Environmental Solutions, LLC
701 E. Bay Street, Suite 306
Charleston, SC 29403
Bank Sponsors – Environmental Banc & Exchange (EBX) and EBX-Neuse I, LLC
AGENT AUTHORIZATION LETTER
PROJECT LOCATION: The project consists of approximately 14,500 feet of proposed sewer force main.
The corridor is located in Durham, along Snow Hill Road and paralleling an existing sewer easement.
The corridor consists of the permanent utility easement associated with the proposed Snow Hill Road
Force Main.
STREET ADDRESS: Northern terminus is located at 2405 Snow Hill Road, Durham, NC. _
Southern terminus is located behind the Hanson Aggregates sales yard at 5013 Denfield St, Durham,
NC.
Please print:
Applicant: City of Durham, Water Management
Applicant Contact Person: Vincent Chirichella, P.E., Sr. Project Manager
The undersigned applicant of the proposed project do hereby authorize
Keven Arrance
(Consultant / Agent)
of Hazen and Sawyer
(Name of Consulting Firm)
to act on my behalf and take all actions necessary for the processing, issuance and acceptance of
the attached permit or certification and any and all standard and special conditions attached.
Applicant's Mailing Address (if different than property above):
5926 Highway 55 East, Durham, NC 27713
Telephone: 919.560.9039
We hereby certify the above information submitted in this application is true and accurate to the
best of our knowledge.
I S'�e. �iZo�Ccf M+��lg4Ett 3 Z° 2�Z/
(Applicant) (Date)
Eno RiverPump Station
Snow Hill RoadPump Station
Proposed Force Main AlignmentTrenchless Installation Technique
Proposed Force Main AlignmentOpen Cut Installation
Proposed Force Main AlignmentOpen Cut Installation
Figure 1: Topographic MapSnow Hill Road Force MainDurham CountyDurham, North Carolina®1 inch = 2,000 feet
0 1,000 2,000500Feet
Legend
Force Main Alignment
Limits of Disturbance
Stream
Wetlands
Pond
DURHAM COUNTY, NORTH CAROLINA — SHEET NUMBER 13
Ge6 2020000FEET _ Wn MfB AI9 (Joins sheet 10) _ 13
/
11rC Hr8 MtC '4 \� 3 `� j -, ti =
s.v tB +� f - AIB
GeB °p v NrC l a - 11r. Hrc HrB a� MfD " z,� C`' - q6t)�
�gB HrB \ HrC F{.8 GeB -�' I ��.• `rflI 1 MfC N
MfC CrB GfF r'S '\O Ch - Ro
'�� �• � n HrC -� MTC HrC
\ _
Ch
r _ _
G0� ti .-_♦ - Hr6 _x l Qj ? C MfC
Cr•B GeC GeB Non ` l ,�� / !C by Vf M
`. r =
1' HUr`
Hr6
�._ M TC
- '`a. ' •i `` tL ,` W MfC MfC
m
HrB ,Y = 1 �ySB. Ire
- MIS Wr t o
,.1NrC M!C . 'y ? 0 r IrC�� CrR MTD 4
GeD J B HrS / ,/ / F' MfC 0 G' f Lo
1 _ _ Mf8 _ _ C
GeC _ i_ / {!.- Hr8 r' ti+8 1 - MTB �1 .�; J~ MIS J r` / MtB / T�
Hr8 ' CiZ _J !I- rya N� ,�
Mf
Muc D
D !
I n �1.
v HrC �' NaDa Ro -f ¢ Ir8
A GeC � MfC ) �1
HrC q; t >tbs _� WsE
Cs 1
r53 �l 1 I
' W r - HrCcl
ec Mf6 -� i G _ - _ Irc
HrC H �
! MfC a) Lg0 G t L {t 0 0 0 t I) G G IrC MIS
40
r GeB CrB I 0 0 �I %a_ - �T j WSE
Hrft H:C Q MuB Hea �0 0 0 �1 IrC i jj fr6 M
aO �^ 0 / MfC 1 v
�01u (I 0 IrB I 0 Ire G r MSB Q.
M B t l ,'Ire U IrB Mf6 '
fr6 �-� '� - m'I' p
0 � WXE ; II
rr p Mfc ii
vp
Ch
Ch
}- 1 G p 0 1rC
p •' Et •Ir8
`sZ 3 _ MuC �' "Ir6 0 Ro AfA Ir6
Na, C 0 �-
z "'•' -- ! HrC Wh �l j cP �, Ch ' W-E o
4 0
'..�
sO - Hr6 Y Cp
CJ y HrC eO } f P rK _1.
l Ch
Hr8 GeB AlB cp 1
GeC
- h N 'fit Ter +w-
o ri r- O
'
_ Au6 _ - v r { Mf Ch -
O
' {
- � +s.� HrC u. u'� � - Wn AIA .i' ,..
Mu
j
f J FQ Y I NaD M(f3
p �+ Gm' GeC ► + Mf6
7aE ,Y ' C 0 } 6 .* I ,i _ - . Wh AIA A/%
A J r \ MfE / , $! Ir 1 / O
l T Cf X HrC NrB p* • C AIB l
Mfg U GeD Wm M fc LSr - �s _ f� AIB _ [�
CG fr6 ` Muc
1_ 0 D IrC P(E Ch
Na- / Y
%. cp. 0 NdD AIB - f
WE _ 11
I1p 5. �� MID r
a- El ? - GIF f /•1 X; .I II` - /tea{ei.. W ,� 3 Gp o
Mf8 r AIA
/6 Ou �''
IrC - "� I :. -
p
AIB G D G
If IQ Ch MfC fB � � � {,
fr6 I MfC i
MfC <o. Mf8 MfC WE - _ pa
1 Mt6 %' p MfE
MfD ..fir P,' GeC We IrC
MfD
• � y� j � � tMfe
W5B Mf6
IrB MfC HeC = j MiFR fl
AI6. CrS MfB
5 ur O
GIE GeB rC SOS WsC Cr8 J�
M Hr6 pj fC
- IrC 1 Cn�y� 0
4 fc WSB Ch�! IrB NaA Mf6 W`B I ..
YM7D ' I C ' _ HrE3 r MTB Mf8
W5 Mfg R �Fe
;w Ws9 MTD
rr)�3 IrC MfC j 4
1
? _INf$ -Ir8 T t I Mf8 M - Gu lj Ws8
_Ire_ _ -
DURHAM COUNTY. NORTH CAROLINA — SHEET NUMBER 14IF X rC 2 055 pp0 FEET Cp crG wsE Cr$
/p
1.4 - - ---!c•ir�s sheer i ' .. — _ - -- - — --- - - -
`1
M4C rB prC/_-
N PFE / '�5./ ` GK GrC - C _ Wvrl
Alb T
Min
r'L'
l 3Cc. Mf6 MtC
- 1 R Ch MfB i(I y �f GrB _ ` co ! L IN
Ch CP
MfE li u VVI ii
-�. Grd U - _ /. {,MfC FALLS \ f
r fl . RF.SF.R; UIR
AIR MfC MfC I '" CrC MfB WsC f . f ` I AIA t\ .
f ! MID rim ti� 11 MEC
ri I MMtR Gn
CtC MtB cpi-
O MiB Y.\ GrC T
u) < GrC I.I . 4a i-�� Wn G �L Ch
PSE Cc 2 1 ., CYB - /:� '' Co i�� l _ \
W `f
WsE Ro Cc 1, Gr 1 �(� WsB i''i` =µEi- o�R I:rl� CP
CrB 3� /' f ...i ��/� - l ? / _ r cot•+a'rt
MtD r 1 / / -' AM
Mfc 1 AlA AIA MfA \
MfB WNWMGr6
y y Ch
/ v
j Gp
Cp t,
Ch
a Wcr; �r WsB GP
Mf
C PD4R w Co 1 - ^ ' \�� AIB -�•'� m
f6 _ ,fti y _ ` Ch` i' - Cr ' --"� / +/ 10 AIA
+ Ch �J;_/ /�ii- 4v I�i '!t' c\ /! '\
AIA a
�.� �� \� \\`, ✓_,// ~l
WsB % 11 l- C4e,
p I- i _ Ea
w56 ITT 11 11 i� wsc �'Ea
{�
Dc'
Cp .CA N AIB / , f Ch Q
0 CrC Cp J' !'., Cr8 AIR
r Z U
r` if
I' - `FALLS i
9 irB f ti cp } 4i RESER4'OIR
wsB ,
Wn
IrC '• _-.—.�f I �l — tip. A =;i _--- r--- = o
AIA 4 �- . y 4. - CrB
l%�B if o00 6 F Ch Ro
I % 6 // AIR r of
c
,c irB \ G wsc It /o
n G V C z d
AIA ° v
p 0 IrB ' Cp 1" WsC
0 et r / o WSB MfB I /� z
h
FOOD r 'W58,q ilriJ Cr8 U
-..ch ` - 0 -:- Wn - WsE _
1 2
0Mu AIB WsC IrC / - l „ C j Cp VJn } n Q _
0
Cn �. • HeB ` MfC _ Of
O : , Mua - ALB ^ W56 CrB 0 �r .
(,r6 I CrC WsB W5B ❑
�? f WsE �- I I
W muc IrC ` Wsc _ o
Ch Cfa� WsC 1 Ws$ 0 SIG MfB~
CID i, _\ i
Oo WxE �..` h CA Ws8 1 ; \„\ L'� n CrC
G h'J<<� - CrB WsB C,r,.8
/ Ir '`� i Shy WsE _ ` WsB ! '� I� W5E
Cp p
r.
u 0 ii -
rr' G� Cr8 1 _
M.0 Ch i" WsC f } Ne$
G I1
n w % _
11i 1r8 Cr
o cof uMfP �' 11 7 ✓ E9 WsC
O / M6 f"E - 'I --` i 0 MfB Vf N tic \\1 �:.. WsE
IrC AIA / ` We 1% fl }sr WSE \ W5G' 1k • CrB 1 , �I 46/
f^ j Mtc WsE i CrC II iJ ��- GrC II SB
It
o PfE - GrB Gr$ \\ �� \ CrC t 1 C \ t1 �t� Ch /.
MfB \ '- CrC N } = l.F4LI.S
v WsB y it CrB R7ff wSB WsC Ws6 \ I yWsC ? 4 ✓
I I RESERVOIR
j' 3 Mf0 l _� fIII
MfHeB W5B - = n U + o _
tl B 6: J/. " // J r
� ! � ` Mts � 3 : � G� � wsc
GrB f' wsc
Ire MfB fir' - „ n _ wn WsB n f7 GG 11 AIB a ,
O - MfC '. 1' ' C' He$ MfB / l 3' HeB
00 MfB ' Crc - CrB
0 i I
�s Wn IN �r �' wsc 4} it Ro
B MfB WsC ✓z IrC w 1\ �� n WsG ` IrC IrC ti i Mua MuC YGu
Irk- _ ptF- MiBi., _ y�5 WsC v,.. 1 s� !; CrB ..
rB V Mfc He$ a CrB CI Ro GrC AIB Al floc WsB
z G`C Gr8 CrB ti'� MfC M[C WsE C� WsB Ch Ch . ✓�. Irc
} fJoins sheet l } WE MfC MfD - ~- -
wsC
Eno RiverPump Station
Snow Hill RoadPump Station
Figure 2: Vicinity MapSnow Hill Road Force MainDurham CountyDurham, North Carolina®1 inch = 1,500 feet
0 1,5005001,000 Feet
Legend
Force Main Alignment
Limits of Disturbance
Stream
Wetlands
Pond
Snow Hill RoadI n f i n i t y R o a d
E n o R i v e r
Cabin Branch
Little River
File: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\GENERAL\31453-000 COVER Saved by ENG Save date: 11/2/2020 4:35 PMPLOT DATE: 1/20/2021 9:23 AM BY: AMARCHCITY OF DURHAM
NORTH CAROLINA
SNOW HILL ROAD
FORCE MAIN PROJECT
HAZEN CONTRACT NO. 31453-000
JANUARY 2021
HAZEN AND SAWYER
4011 WESTCHASE BOULEVARD, SUITE 500
RALEIGH, NORTH CAROLINA 27607
LICENSE NO. : C-0381
OLD
O
X
F
O
R
D
R
D
LITTLERIVEROLD OXFORD RDENOENO RIVE
R
INFIN
I
T
Y
R
DN ROXBORO RDSNOW HILL RDENO RIVERDENFIELD STHEBRON RD
LA
T
T
A
R
D
HORTON RD
RIVER
GOD
W
I
N
R
D
STANLEY RDSNOW HILL
PUMP STATION
ENO
PUMP
STATION
90% SUBMITTAL - NOT FOR CONSTRUCTION
GRAVEL
SOIL
SOIL
SOI
L
GRAVEL
GRAVEL
SOIL
GRAVEL
GRAVEL
4' W
I
RE
4' W
I
R
E
4' W
I
R
E
GRAVEL
SOIL PA
T
H SOIL PA
TH
SOIL P
AT
H
SOIL
P
A
T
H
SOIL PATHSOIL P
AT
H
SOI
L
P
A
T
H
SOIL PA
T
H
SOIL PATH
SOIL PATH
SOIL PA
T
H
SOIL PATHSOIL PATHSOIL
P
A
T
H
SO
IL
P
A
TH
SO
I
L
P
A
T
H
SOIL PATH
SOIL PATHGRAVE
L
SOIL P
AT
H
GRAVEL
GRAVEL
GRAVEL
GRAVEL
GRAVEL
4' W
I
RE
4' W
I
R
E
4' W
I
R
E
PLOT DATE: 1/20/2021 9:05 AM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\GENERAL\G1 Saved by AMARCH Save date: 1/19/2021 5:12 PMSNOW HILL ROAD
FORCEMAIN
31453-000
01
JANUARY 2021B. PORTER
IF THIS BAR DOES NOT
MEASURE 1" THEN DRAWING
IS NOT TO FULL SCALE
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT
ENGINEER:
REV ISSUED FOR DATE BY
0 1"1/2"
CONTRACT NO.:
HAZEN NO.:
DATE:
DRAWING
NUMBER:HAZEN AND SAWYER
4011 WESTCHASE BOULEVARD, SUITE 500
RALEIGH, NORTH CAROLINA 27607
LICENSE NO.: C-0381
WHARTON-SMITH, INC.
5601 77 CENTER DRIVE #120, CHARLOTTE,
NORTH CAROLINA 28217
90% SUBMITTAL - NOT FOR CONSTRUCTION
N. JOHNSON
E. NG
G1
KEY MAP AND DRAWING INDEX
B. PORTER SNOW HILL
RDSNOW HILL RDENO
RI
V
E
R
ENO RIVER
ENO
R
I
V
ER
ENO
RIVE
R
ENO
PUMP STATION
SNOW HILL
PUMP STATION
SNOW HILL RDC1C2C3C4C5C6C7C8C9C10C11C13
C13
C14
C15C20C21C22C2
3
C24
SCALE: 1" = 600'
KEY MAP
SNOW V
A
L
L
E
Y
R
D
WA
N
D
E
R
L
U
S
T
L
N
STANLEY RDENO RIVER DRGENERAL
DESCRIPTION
G1
NUMBER
COVER
DRAWING
C1 STATION 0+00 TO 7+00
CIVIL
C2 STATION 7+00 TO 14+00
INDEX OF DRAWINGS
KEY MAP AND DRAWING INDEX
C3 STATION 14+00 TO 21+00
C4 STATION 21+00 TO 28+00
C5 STATION 28+00 TO 35+00
C6 STATION 35+00 TO 42+00
C7 STATION 42+00 TO 49+00
C8 STATION 49+00 TO 56+00
C9 STATION 56+00 TO 63+00
C10 STATION 63+00 TO 70+00
C11 STATION 70+00 TO 77+00
C12 HDD OVERALL PLAN & PROFILE
C13 STATION 77+00 TO 91+00 (PLAN)
C14 STATION 91+00 TO 105+00 (PLAN)
C15 STATION 105+00 TO 111+00 (PLAN)
C16 STATION 77+00 TO 86+00 (PROFILE)
C17 STATION 86+00 TO 95+00 (PROFILE)
C18 STATION 95+00 TO 104+00 (PROFILE)
C19 STATION 104+00 TO 111+00 (PROFILE)
C20 STATION 111+00 TO 118+00
C21 STATION 118+00 TO 125+00
LINETYPE
NATURAL GAS
FORCE MAIN
ELECTRIC
TELEPHONE
WATER LINE
FIBER OPTIC CABLE
TREELINE
CABLE TV
OVERHEAD ELECTRICAL
UNDERGROUND ELECTRICAL
DITCH
INTERMEDIATE CONTOUR
EXISTING
FENCE
PROPERTY LINE
EASEMENT LINE
STRUCTURE
SANITARY SEWER
PROPOSED
PERMANENT EASEMENT
TEMPORARY
CONSTRUCTION EASEMENT
DETAILS
D1 STANDARD DETAILS
C24 STATION 139+00 TO 146+00
C23 STATION 132+00 TO 139+00
C22 STATION 125+00 TO 132+00
C14
BUFFER ZONE 1
BUFFER ZONE 2
FORCEMAIN
DURHAM BUFFER
SYMBOLS
LIGHT POLE
GUY WIRE ANCHOR
EXISTING
MANHOLE
PROPOSED
ARV MANHOLE
VALVE
INDEX CONTOUR150
TEMPORARY BENCHMARK
D2 STANDARD DETAILS
D3 STANDARD DETAILS
POWER POLE
D4 STANDARD DETAILS
D5 STANDARD DETAILS
D6 STANDARD DETAILS
D7 STANDARD DETAILS
G2 NOTES
VALVE
YARD INLET PROTECTION
TPF TREE PROTECTION FENCE
SF SILT FENCE
DIVERSION SWALE
GRAVEL CONSTRUCTION
ENTRANCE
LOD LIMITS OF DISTURBANCE
EROSION CONTROL
TEL PED
FLARED END SECTION
ABBREVIATIONS
EOP
LOD
OHE
SSEDGE OF PAVEMENT
LIMITS OF DISTURBANCE
OVERHEAD ELECTRIC
SANITARY SEWER
FOC FIBER OPTIC CABLE
W WATER
G GAS
PROPERTY LINE
CENTER LINE
LP LIGHT POLE
UGE UNDERGROUND ELECTRIC PP POWER POLE
PL
CL
ROLLED EROSIONRECM
CONTROL MATTING
ACF ANNUAL CHANCE FLOOD
UGT UNDERGROUND TELEPHONE
CHANNEL LINING
FFT
FIBER FILTRATION TUBE
NCG01 GROUND STABLIZIATION AND MATERIALS HANDLING
NCG02 SELF-INSPECTION, RECORDKEEPING, AND REPORTING
PLOT DATE: 1/20/2021 9:05 AM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\GENERAL\G2 Saved by AMARCH Save date: 11/5/2020 2:44 PMSNOW HILL ROAD
FORCEMAIN
31453-000
01
JANUARY 2021B. PORTER
IF THIS BAR DOES NOT
MEASURE 1" THEN DRAWING
IS NOT TO FULL SCALE
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT
ENGINEER:
REV ISSUED FOR DATE BY
0 1"1/2"
CONTRACT NO.:
HAZEN NO.:
DATE:
DRAWING
NUMBER:HAZEN AND SAWYER
4011 WESTCHASE BOULEVARD, SUITE 500
RALEIGH, NORTH CAROLINA 27607
LICENSE NO.: C-0381
WHARTON-SMITH, INC.
5601 77 CENTER DRIVE #120, CHARLOTTE,
NORTH CAROLINA 28217
90% SUBMITTAL - NOT FOR CONSTRUCTION
N. JOHNSON
E. NG
G2
NOTES
B. PORTER
GENERAL
1.THE CONTRACTOR IS SOLELY RESPONSIBLE FOR SITE SAFETY ASSOCIATED WITH THE
WORK UNDER THIS PROJECT AND FOR COMPLIANCE WITH ALL FEDERAL, STATE AND LOCAL
HEALTH AND SAFETY LAWS, CODES, REGULATIONS, AND ORDINANCES INCLUDING, BUT NOT
LIMITED TO, THOSE CURRENTLY MANDATED BY THE OCCUPATIONAL SAFETY AND HEALTH
ADMINISTRATION (OSHA).
2.CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE DESIGN, INSTALLATION, AND
MAINTENANCE OF ALL EXCAVATION SUPPORT ON THE PROJECT. ALL EXCAVATION SUPPORT
SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF NORTH
CAROLINA. ALL EXCAVATION SUPPORT DESIGN DOCUMENTS SHALL BE PRESENTED TO THE
ENGINEER FOR REVIEW BEFORE IMPLEMENTATION. CONTRACTOR SHALL USE ADEQUATE
SHORING METHODS TO ENSURE:
A.COMPLIANCE WITH OSHA REGULATIONS.
B.PROTECTION OF EXISTING PAVEMENT AND ROAD SHOULDERS, STRUCTURES AND
UTILITIES.
C.CONSTRUCTION ACTIVITIES ARE CONFINED TO RIGHTS-OF-WAY OR EASEMENTS AS
INDICATED
3.LIMITS OF DISTURBANCE (LOD) SHALL BE AS INDICATED ON THE CONTRACT DRAWINGS. ANY
CHANGES TO THE LOD BY THE CONTRACTOR SHALL REQUIRE PRIOR APPROVAL FROM THE
ENGINEER AND DEMLR LAND QUALITY SECTION.
4.CONTRACTOR SHALL REPAIR AT HIS OWN EXPENSE, ANY DAMAGE CAUSED BY
CONSTRUCTION RELATED ACTIVITIES TO EXISTING UTILITY SERVICE LINES.
5.IN THE EVENT OF DAMAGE TO EXISTING UTILITIES, CONTRACTOR SHALL STOP WORK
IMMEDIATELY, TAKE NECESSARY PRECAUTIONS TO PREVENT INJURY OR FURTHER DAMAGE,
AND NOTIFY PROPER AUTHORITIES. CONTRACTOR SHALL BE RESPONSIBLE FOR
RESTORING/REPAIRING ALL EXISTING STRUCTURES, CONDUITS, OR OTHER UTILITIES
DAMAGED BY CONTRACTOR'S OPERATIONS AT NO COST TO OWNER.
6.REMOVAL AND REPLACEMENT OR REPAIR OF EXISTING UTILITY SERVICES SHALL BE
COORDINATED WITH APPROPRIATE UTILITY COMPANY AT NO ADDITIONAL COST TO THE
OWNER.
7.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL AND REPLACEMENT TO
ORIGINAL OR BETTER CONDITION OF ALL EXISTING PAVEMENTS, FENCES, AND
MISCELLANEOUS ITEMS WHERE DAMAGED BY CONSTRUCTION ACTIVITIES OR REQUIRED TO
COMPLETE THE CONSTRUCTION.
8.ALL HOLES, TRENCHES, AND OTHER HAZARDOUS AREAS SHALL BE ADEQUATELY
PROTECTED BY BARRICADES, LIGHTS OR OTHER PROTECTIVE DEVICES.
9.REMOVAL OF EXCAVATED MATERIALS AND DAILY CLEANUP OPERATIONS SHALL BE
PERFORMED IN COMPLIANCE WITH THE SPECIFICATIONS AND TO THE SATISFACTION OF THE
OWNER/ENGINEER.
10.EXCESS/UNSUITABLE SPOIL TO BE REMOVED FROM SITE. PRIOR TO BEGINNING
CONSTRUCTION, CONTRACTOR SHALL SUBMIT THE OFF-SITE SPOIL LOCATIONS TO BE USED
AND PROVIDE DOCUMENTATION OF EROSION CONTROL MEASURES TO BE PROVIDED
DURING DISPOSAL OPERATIONS. CONTRACTORS OFF-SITE SEDIMENT CONTROL MEASURES
MUST BE APPROVED BY NC DEMLR PRIOR TO SPOIL DISPOSAL.
11.ALL EROSION AND SEDIMENTATION CONTROLS SHALL BE IMPLEMENTED BEFORE
CONSTRUCTION COMMENCES AND SHALL NOT BE REMOVED UNTIL PERMANENT GROUND
COVER STABILIZATION HAS BEEN ESTABLISHED.
12.THE CONTRACTOR SHALL RECORD AND SUPPLY TO THE ENGINEER THE FOLLOWING
INFORMATION:
A.THE LOCATION OF ALL UTILITIES CROSSED AND THE NEW LOCATION AND DEPTH OF
ALL RELOCATED AND/OR ADJUSTED UTILITIES.
13.DAMAGED OR REMOVED DRIVEWAY CULVERTS SHALL BE REPLACED WITH THE SAME SIZE
AND MATERIAL THAT EXISTED PRIOR TO CONSTRUCTION AND BE IN COMPLIANCE WITH
CURRENT NCDOT STANDARDS. NCDOT REQUIRES A MINIMUM OF 15" RCP FOR ALL NEW AND
REPLACED CULVERTS. APPLY APPROPRIATE EROSION & SEDIMENTATION CONTROL
MEASURES TO ALL RESTORED AREAS INCLUDING DITCH LINES, SWALES, AND CULVERTS.
14.THE CONTRACTOR SHALL PROVIDE ADEQUATE SUPPORT FOR ALL UTILITY POLES AS
NECESSARY. COMPACT TRENCH FIVE (5) FEET EACH SIDE OF UTILITY POLES TO A MINIMUM
OF 95% STANDARD PROCTOR. THE CONTRACTOR SHALL COORDINATE UTILITY POLE
SUPPORT WITH THE APPROPRIATE UTILITY COMPANIES.
1.CONTRACTOR TO POST EROSION CONTROL PERMIT ON JOB SITE AS REQUIRED.
2.ALL EROSION CONTROL MEASURES SHALL BE IN PLACE BEFORE ANY LAND
CLEARING OR DISTURBANCE ACTIVITIES MAY BEGIN.
3.A RAIN GAUGE SHALL BE MAINTAINED IN GOOD WORKING ORDER ON THE SITE
UNLESS ANOTHER RAIN-MONITORING DEVICE HAS BEEN APPROVED BY THE NC
DIVISION OF WATER QUALITY. A WRITTEN RECORD OF THE DAILY RAINFALL
AMOUNTS SHALL BE RETAINED AND ALL RECORDS SHALL BE MADE AVAILABLE
TO THE DIVISION OF WATER QUALITY. REFER TO THE NC NPDES GENERAL
PERMIT NCG010000, SECTION II.B.(3)(B), FOR ADDITIONAL INFORMATION.
4.THE CONTRACTOR SHALL FURNISH AND INSTALL ALL NECESSARY EROSION
CONTROL MEASURES WHETHER OR NOT SHOWN ON THE PLANS TO PROTECT
ADJACENT CREEKS, RIVERS, ROADWAYS, ETC. FROM SILTATION AND EROSION.
5.ALL EROSION CONTROL MEASURES SHALL BE INSPECTED WEEKLY AND WITHIN
24 HOURS OF ANY RAINFALL EVENT THAT PRODUCES 1/2 INCH OR MORE OF
RAIN. REPAIR AND/OR REPLACE AS NECESSARY. SEE STANDARD DETAILS ON
CONTRACT SHEET DC3 FOR SPECIFIC MAINTENANCE REQUIREMENTS FOR EACH
EROSION AND SEDIMENT CONTROL MEASURE UTILIZED ON THIS PROJECT.
6.EROSION CONTROL MEASURES SHALL BE CLEANED OF ACCUMULATED
SEDIMENT WHEN VOLUME OF MEASURE IS HALF FULL. SEDIMENT SHALL BE
REMOVED FROM BEHIND SILT FENCING WHEN IT BECOMES APPROXIMATELY 0.5
FEET DEEP AT THE FENCE. THE SEDIMENT FENCE SHALL BE REPAIRED AS
NECESSARY TO MAINTAIN THE BARRIER. REMOVED SEDIMENT SHALL BE
DISPOSED OF IN SUCH A MANNER AS TO PREVENT FURTHER SEDIMENT
TRANSPORT. IF NO SUITABLE ON-SITE LOCATIONS ARE AVAILABLE, ALL
REMOVED SEDIMENT WILL BE LEGALLY DISPOSED OF OFF-SITE AT NO
ADDITIONAL COST TO THE OWNER.
7.ALL EXCESS SOIL RESULTING FROM EARTHWORK OPERATIONS SHALL BE
REMOVED FROM SITE BY CONTRACTOR. ALL TEMPORARY SOIL STOCKPILE
AREAS USED FOR BACKFILL AND OTHER ACTIVITIES SHALL BE WITHIN THE LOD
AS SHOWN ON THE DRAWINGS, AND LOCATED, AT A MINIMUM, 50 FEET FROM
ANY SURFACE WATERS. STOCKPILE SIDE SLOPES SHALL BE NO STEEPER THAN
3:1 AND TOP OF STOCKPILE SHALL BE SLOPED AT A MINIMUM OF 5% TO
PROMOTE POSITIVE DRAINAGE. ALL ONSITE TEMPORARY SOIL STOCKPILES
SHALL BE SEEDED WITH TEMPORARY AND/OR PERMANENT SEEDING MEASURES
FOR THE DURATION OF CONSTRUCTION ACTIVITIES. ALL CONTRACTOR STAGING
AND LAYDOWN AREAS, SOIL OR WASTE STOCKPILE AREAS SHALL HAVE
PERIMETER SILT FENCE. LOCATED NO CLOSER THAN 6 FEET FROM TOE OF
SLOPE TO ALLOW FOR ACCESS AND MAINTENANCE. ANY SOILS TAKEN OFF SITE
BECOMES THE CONTRACTORS RESPONSIBILITY AND SHALL COMPLY WITH ALL
REQUIRED STATE AND LOCAL REGULATIONS AND PERMITS.
8.ALL EROSION CONTROL MEASURES SHALL REMAIN IN PLACE UNTIL ENTIRE SITE
IS PERMANENTLY STABILIZED WITH VEGETATION AS PER SEEDING
SPECIFICATIONS AND SCHEDULE. ALL TEMPORARY EROSION CONTROL
DEVICES ARE TO BE REMOVED AFTER PERMANENT STABILIZATION HAS BEEN
ACHIEVED AND APPROVAL HAS BEEN GRANTED BY THE LAND QUALITY SECTION
AND ENGINEER.
9.RESTORE ALL DISTURBED AREAS INCLUDING DITCHES/SWALES,
STAGING/LAYDOWN/PARKING AREAS TO ORIGINAL GRADE AND ELEVATION AND
ORIGINAL OR BETTER CONDITION, EXCEPT WHERE NOTED ON THE CONTRACT
DRAWINGS.
1.CONTRACTOR SHALL SIGN AND IMPLEMENT THE REQUIREMENTS OF THE STATE
APPROVED EROSION CONTROL PLAN AND THE NORTH CAROLINA NATIONAL
POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) GENERAL PERMIT FOR
STORMWATER DISCHARGES ASSOCIATED WITH CONSTRUCTION ACTIVITY. THE
CONTRACTOR SHALL NOTIFY THE STATE LAND QUALITY SECTION AT (919) 791-4200 TO
SCHEDULE A PRE-CONSTRUCTION MEETING. ADDITIONALLY, THE CONTRACTOR SHALL
NOTIFY THE STATE LAND QUALITY SECTION, AT (919) 791-4200 AT LEAST 48 HOURS
PRIOR TO BEGINNING CONSTRUCTION ACTIVITIES. EROSION AND SEDIMENT CONTROL
(E&SC) PERMIT AND A CERTIFICATE OF COVERAGE (COC) MUST BE OBTAINED BEFORE
AND LAND DISTURBING ACTIVITIES OCCUR.
2.INSTALL ALL PERIMETER TEMPORARY SEDIMENT AND EROSION CONTROL MEASURES
IN LOCATIONS AS SHOWN ON THE CONTRACT DRAWINGS. THIS INCLUDES, BUT IS NOT
LIMITED TO, THE INSTALLATION OF SILT FENCE, TREE PROTECTION FENCE, AND,
GRAVEL CONSTRUCTION ENTRANCE. NO CONSTRUCTION OR LAND DISTURBANCE
ACTIVITIES MAY BEGIN UNTIL ALL TEMPORARY SEDIMENT AND EROSION CONTROL
MEASURES HAVE BEEN INSTALLED. CLEAR ONLY THE AREA REQUIRED FOR
INSTALLATION OF EROSION CONTROL MEASURES.
3.ONCE ALL TEMPORARY PERIMETER EROSION CONTROL MEASURES HAVE BEEN
INSTALLED, THE SITE SHALL BE CLEARED AND GRUBBED, AS REQUIRED, WITHIN THE
LIMITS OF DISTURBANCE (LOD) AS SHOWN ON THE CONTRACT DRAWINGS (C2). ANY
ADJUSTMENTS TO THE LOD SHALL REQUIRE PRIOR APPROVAL FROM THE ENGINEER
AND OWNER.
4.ALL DEBRIS FROM TREE CLEARING SHALL BE REMOVED FROM SITE. NO BURNING OF
DEBRIS WILL BE ALLOWED.
5.ONCE ALL TREE CLEARING HAS BEEN COMPLETED, CONTRACTOR SHALL REROUTE
THE 4" SANITARY SEWER LINE AS SHOWN ON CONTRACT DRAWING C4. CONTRACTOR
SHALL PHASE CONSTRUCTION AS TO NOT INTERFERE WITH EXISTING FLOW THROUGH
THE SEWER. ONCE THE EXISTING SANITARY SEWER HAS BEEN REROUTED,
CONTRACTOR MAY BEGIN EXCAVATION AND PHASE 2 SITE ACTIVITIES. ALL EROSION
CONTROL PRACTICES SHALL REMAIN IN PLACE WHEN CONSTRUCTION TRANSITIONS
TO PHASE 2.
6.PHASE 2 INCLUDES ALL SITE ACTIVITIES FOR THE CONSTRUCTION OF THE NEW PUMP
STATION. THIS INCLUDES ADDITIONAL REROUTING OF SEWER/UTILITIES, AND
CONSTRUCTION OF THE PUMP STATION AND ASSOCIATED FACILITIES, ROADWAY, AND
PIPING.
7.ALL EXCESS SOIL RESULTING FROM ANY EARTHWORK OPERATIONS NECESSARY
SHALL BE REMOVED FROM SITE BY CONTRACTOR. ANY SOILS TAKEN OFFSITE
BECOMES THE CONTRACTOR'S RESPONSIBILITY, AND SHALL COMPLY WITH ALL
REQUIRED STATE AND LOCAL REGULATIONS AND PERMITS.
8.TEMPORARY SEEDING MEASURES SHALL BE EMPLOYED AS SOON AS PRACTICABLE ON
DISTURBED AREAS BUT IN ANY EVENT WITHIN FOURTEEN (14) DAYS. DISTURBED
SLOPES STEEPER THAN 3:1 SHALL BE TEMPORARILY SEEDED WITHIN SEVEN (7) DAYS
UNLESS SLOPE LENGTH IS TEN (10) FEET OR LESS AND NOT STEEPER THAN 2:1.
DISTURBED SLOPES 3:1 OR FLATTER SHALL BE TEMPORARILY SEEDED WITHIN
FOURTEEN (14) DAYS UNLESS SLOPE LENGTH IS GREATER THAN 50 FEET.
9.WHEN THE PROJECT IS COMPLETE, THE PERMITTEE SHALL CONTACT DEMLR TO
CLOSE OUT THE E&SC PLAN. AFTER DEMLR INFORMS THE PERMITTEE OF THE
PROJECT CLOSE OUT, VIA INSPECTION REPORT, THE PERMITTEE SHALL VISIT
DEQ.NC.GOV/NCG01 TO SUBMIT AN ELECTRONIC NOTICE OF TERMINATION (E-NOT). A
$100 ANNUAL GENERAL PERMIT FEE WILL BE CHARGED UNTIL THE E-NOT HAS BEEN
FILLED OUT.
10.THE DESIGN PROFESSIONAL (A NCPE, NCPLS, OR NCRLA - AS REQUIRED) SHALL
SUBMIT ONE (1) SET OF AS-BUILT DRAWINGS TO THE PUBLIC WORKS DEPARTMENT -
DEVELOPMENT REVIEW FOR REVIEW AND APPROVAL. AS-BUILT DRAWING APPROVAL
IS REQUIRED PRIOR TO WATER METER INSTALLATION AND/OR SANITARY SEWER
SERVICE CONNECTION AND PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY.
CONSTRUCTION SEQUENCEEROSION CONTROL
DURHAM PLANNING GENERAL CONDITIONS OF APPROVAL - LANDSCAPING NOTES:
1.LANDSCAPE MULCH: PINE STRAW SHALL NOT BE USED AS MULCH OR GROUNDCOVER WITHIN TEN FEET OF ANY STRUCTURES CONSISTING OF
EXTERIOR COMBUSTIBLE CONSTRUCTION AS SPECIFIED BY DURHAM CITY CODE SECTION 46-87.
2.LANDSCAPING/C.O. STANDARDS NOTE: ALL LANDSCAPING MUST BE IN PLACE PRIOR TO REQUEST FOR A CERTIFICATE OF COMPLIANCE. CONTACT
DURHAM CITY COUNTY PLANNING DEPARTMENT SITE COMPLIANCE STAFF FOR INSPECTION
3.LANDSCAPE RE-INSPECTION FEE: EACH LANDSCAPING COMPLIANCE INSPECTION AFTER THE INITIAL INSPECTION WILL INCUR A RE-INSPECTION
FEE. PAYMENT MUST BE RECEIVED BY THE DURHAM CITY COUNTY PLANNING DEPARTMENT PRIOR TO RE-INSPECTION.
4.UNDISTURBED LANDSCAPE BUFFERS: 60-FOOT WIDE UNDISTURBED LANDSCAPE BUFFER. NO CLEARING OR GRADING OTHER THAN SELECTIVE
THINNING AND ORDINARY MAINTENANCE OF EXISTING VEGETATION PERMITTED.
5.CONSTRUCTION IN PRESERVED TREE COVERAGE AREAS (UDO SECTION 8.3):
A.PRESERVED TREE COVERAGE AREAS SHALL NOT BE USED FOR ACTIVE RECREATIONAL PURPOSES, EXCEPT FOR WALKING PATHS AND FOOT
TRAILS CONSTRUCTED WITH MINIMAL DISTURBANCE OF TREE ROOTS AND EXISTING VEGETATION PROVIDED A REGISTERED ARBORIST HAS
CERTIFIED THAT THE CONSTRUCTION OF THE TRAIL HAS BEEN DESIGNED TO MINIMIZE IMPACT TO THE EXISTING TREES. NO TREE OVER 10
INCHES SHALL BE REMOVED FOR THE CONSTRUCTION OF TRAILS. SITE PLAN APPROVAL IS REQUIRED FOR CONSTRUCTION OF TRAILS IN
PRESERVED TREE COVERAGE AREAS.
B.ALL BUILDINGS SHALL BE SET BACK AT LEAST 10 FEET FROM THE EDGE OF ANY PRESERVED TREE COVERAGE AREA.
C.UTILITY LINES AND DRAINAGE CHANNELS SHALL BE MINIMIZED WITHIN THE ROOT PROTECTION ZONES OF THE TREES TO BE SAVED.
6.TREE PROTECTION FENCING MUST BE IN PLACE PRIOR TO ANY DEMOLITION, LAND DISTURBANCE, OR ISSUANCE OF A GRADING PERMIT AND
SHALL INCLUDE WARNING SIGNS POSTED IN BOTH ENGLISH AND SPANISH, AS FOLLOWS: "NO TRESPASSING/TREE PROTECTION AREA/PROHIBIDO
ENTRAR / ZONA PROTECTORA PARA LOS ÁRBOLES."
7.ROOT PROTECTION ZONE EQUALS ONE FOOT OF RADIUS FOR EVERY INCH OF DIAMETER OF EXISTING TREES OR SIX FOOT RADIUS, WHICHEVER IS
GREATER NO DISTURBANCE IS ALLOWED IN THIS AREA. AREA IS TO BE PROTECTED WITH BOTH TREE PROTECTION FENCING AND WARNING
SIGNS.
8.AT THE START OF GRADING INVOLVING THE LOWERING OF EXISTING GRADE AROUND A TREE OR STRIPPING OF TOPSOIL, A CLEAN, SHARP,
VERTICAL CUT SHALL BE MADE AT THE EDGE OF THE TREE SAVE AREA PRIOR TO OR AT THE SAME TIME AS SILT FENCE AND OTHER EROSION
CONTROL MEASURES ARE INSTALLED. THE TREE PROTECTION FENCING SHALL BE INSTALLED ON THE SIDE OF THE CUT FARTHEST AWAY FROM
THE TREE TRUNK AND SHALL REMAIN IN PLACE UNTIL ALL CONSTRUCTION IN THE VICINITY OF THE TREES IS COMPLETE. NO STORAGE OF
MATERIALS, FILL, OR EQUIPMENT AND NO TRESPASSING SHALL BE ALLOWED WITHIN THE BOUNDARY OF THE PROTECTED AREA.
9.CONSTRUCTION DRAWINGS AND SITE PLAN APPROVALS FOR THIS PROJECT ON CONTINGENT ON RECEIVING STORMWATER APPROVAL FROM
NCDEQ. FAILURE TO OBTAIN APPROVAL FROM THE STATE SHALL NULIFY ANY PREVIOUS CITY OF DURHAM SITE PLAN APPROVALS FOR THE
PROJECT.
Xref ..\_Titleblocks\31453-000 - ANSI D-TB.dwg
SEED***
MIXTURE
PLANTING
SEASON LIME*FERTILIZER*
STRAW
MULCH*COMMENTS
P
TS
AUG 15 - MAY 1
MAY 1 - AUG 15
4000
7504000
4000
4000
4000 750 4000
FERTILIZER SHALL BE 10-10-10 ANALYSIS.
TEMPORARY SUMMER SEEDING (LB/AC)
P -
TS -
TW -
*
**
***
APPLICATION RATES IN POUNDS/ACRE
OVERSEED WITH TYPE P
SEED MIXTURE DURING
NEXT PLANTING SEASON
OVERSEED WITH TYPE P
SEED MIXTURE DURING
NEXT PLANTING SEASON
LIME SHALL BE APPLIED AT A MINIMUM OF 2 TONS PER ACRE WITH 3 TONS PER ACRE IN CLAY SOILS.
APPLICATION RATES AND/OR CHEMICAL ANALYSIS SHALL BE CONFIRMED OR ESTABLISHED BY SOIL TEST.
TACK MULCH BY APPLYING AT 0.10 GAL/YD²
SEEDBED PREPARATION NOTES:
1.SCARIFY 2" DEPTH OF SUBGRADE PRIOR TO PLACING TOPSOIL.
2.TOPSOIL SHALL BE SPREAD AT 4" INCH CONSOLIDATED DEPTH
3.APPLY SEED UNIFORMLY WITH A CYCLONE SEEDER, DROP-TYPE SPREADER, OF HYDROSEEDER ON A FIRM,
FRIABLE SEEDBED. IN FINE SOILS, SEEDS SHOULD BE DRILLED 1/4 - 1/2 INCH. IN COARSE, SANDY SOILS, SEEDS
SHALL BE PLANTED NO DEEPER THAN 3/4 INCH. COVER BROADCAST SEED BY LIGHTLY RAKING OR CHAIN
DRAGGING; THEN FIRM SURFACE WITH A ROLLER OR CULTIPACKER TO PROVIDE GOOD SEED CONTACT.
TW AUG 15 - MAY 1
1000
25% DEERTONGUE (Dichanthelium clandestinum)
30% LITTLE BLUESTEM (Schicaryium scoparium)
10% INDIAN WOODOATS (Chasmanthium latifolium)
25% VIRGINIA WILDRYE (Elymus virginicus)
10% SOFT RUSH (Juncus effusus)
TEMPORARY WINTER, SPRING, FALL
SEEDING (LB/AC)
RYE GRAIN (Secale cereale)
WHEAT (Triticum aestivum)
BROWNTOP MILLET (Urochloa ramosa)
GERMAN MILLET (Setaria italica)
****ACTUAL QUANTITY OF BULK SEED IS LARGER, AND IS CALCULATED AS THE REQUIRED PURE LIVE SEED
DIVIDED BY BOTH THE GERMINATION AND PURITY. ENSURE SEEDS ARE PROPERLY STRATIFIED, IF
APPLICABLE, IN ORDER TO ACHIEVE GERMINATION NOTED ON SEED TAG.
SEED MIXTURES TO BE USED ON THE PROJECT SHALL BE AS FOLLOWS (ACCEPTABLE SUBSTITUTES PER SECTION
6.24 OF THE NC EROSION AND SEDIMENTATION CONTROL PLANNING AND DESIGN MANUAL MUST BE APPROVED BY
ENGINEER)
PERMANENT SEEDING
RIPARIAN MIX (15 LB/AC PURE LIVE SEED****)
LAWN MIX (150 LB/AC) TALL FESCUE
SEEDING AND LANDSCAPING
250
255
260
265
270
275
250
255
260
265
270
275
-1+00 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+0020" 45° BENDSTA 0+9520" 45° BENDSTA 1+0520" 45° VERT BENTSTA 0+1620" 45° VERT BENDSTA 0+1220" 45° BENDSTA 1+3620" 45° BENDSTA 1+2220" 45° BENDSTA 0+0720" 45° BENDSTA 0+00SOILSOILSOIL
OHE
OHE
OHE
OHE OHE OHE
OHEOHEOHEOHE OHE OHE OHE
ARV MANHOLERIM = 268.6'TOP OF ARV = 263.8'+/-TOP OF 12" DIP = 261.3'+/-MANHOLE FULL OF WATERCANNOT SEE PIPEVERIFY SIZEGAS GAS GAS
FM FM
FM FM FM
FM FM FM FM
W
W
W
W
W
W
W
W
W
W
WWW
W
W W W W
F
M
FMFMFMW W W W W W W W W
W W
W
FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM
TBM
BENCHTIE SET IN 24" PINE
NAVD '88 ELEV: 271.92'
0
+
0
0
1
+
0
0
2+00
3+00 4+00 5+00 6+00 7+00
STA 0+95
20" 45° BEND
STA 1+05
20" 45° BEND STA 1+22
20" 45° BEND
STA 1+36
20" 45° BENDSTA 0+07
20" 45° BEND
STA 0+12
20" 45° VERT BEND
STA 0+16
20" 45° VERT BENT
265 26527527
0
2
7
5
275SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF
SF SF SF SF
S
F SFSF SFLODLOD
LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
FFT
FFT
266267268
269270
271
PLAN
1" = 30'
PROFILE
H: 1" = 30' V: 1" = 3'PLOT DATE: 1/19/2021 12:41 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C1 Saved by AMARCH Save date: 11/9/2020 11:08 AMSNOW HILL ROAD
FORCEMAIN
31453-000
01
JANUARY 2021B. PORTER
IF THIS BAR DOES NOT
MEASURE 1" THEN DRAWING
IS NOT TO FULL SCALE
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT
ENGINEER:
REV ISSUED FOR DATE BY
0 1"1/2"
CONTRACT NO.:
HAZEN NO.:
DATE:
DRAWING
NUMBER:HAZEN AND SAWYER
4011 WESTCHASE BOULEVARD, SUITE 500
RALEIGH, NORTH CAROLINA 27607
LICENSE NO.: C-0381
WHARTON-SMITH, INC.
5601 77 CENTER DRIVE #120, CHARLOTTE,
NORTH CAROLINA 28217
90% SUBMITTAL - NOT FOR CONSTRUCTION
N. JOHNSON
E. NG
C1
20" FORCE MAIN
PLAN AND PROFILE
STATION 0+00 TO 7+00
B. PORTER MATCHLINE - STA 7+00 SEE SHEET C2NOTES:
1.REMOVE EXISTING RESTRAINED JOINT PLUG AND
MAKE CONNECTION TO EXISTING 20" FM.
2.ELEVATIONS OF UTILITIES SHOWN IN THE PROFILE
ARE APPROXIMATE.
3.CONTRACTOR SHALL VERIFY OD OF EXISTING ARV
MH AHEAD OF PIPE INSTALLATION AND DEFLECT
NEW FM AS NECESSARY AROUND EXISTING MH.
4.LOD LINE IS NOT SHOWN CONTINUOUSLY FOR
CLARITY. THE LIMITS OF DISTURBANCE SHALL BE
COINCIDENT WITH THE PROPOSED EASEMENT LIMITS
AND PROPOSED TEMPORARY EASEMENT LIMITS
WHERE NO LOD IS SHOWN. AFTER THE NEW 20"
FORCE MAIN IS IN SERVICE, ABANDON EXISTING ARV
MH IN PLACE. RETURN ARV AND VALVES TO THE CITY
OF DURHAM.SNOW HILL RD (SR 1631)
20" FORCE MAIN, TYP20'20' PERMANENT EASEMENT, TYP
EX TEL, TYP
EX 30" DIP, TYP
EX 12" FM, TYP
EXISTING GRADE, TYP
20" PC 350 DIP FORCE MAIN, TYP
EX 42" W
EL 265.45±
MIN 18"
E
X
4
2
"
W
E
X
2
4
"
W
EX 24" W
EL 266.25±
EX 42" W
EL 265.16±
UNITED STATES OF AMERICA
ATTN: US ARMY CORPS OF ENGINEERS
D.B. 1057, PG. 659
ADDRESS: 2324 SNOW HILL ROAD
JUDITH STAFFORD
D.B. 7527, PG. 899
ADDRESS: 2320 SNOW HILL ROAD
UNITED STATES OF AMERICA
ATTN: US ARMY CORPS OF ENGINEERS
D.B. 1057, PG. 659
ADDRESS: 2324 SNOW HILL ROAD10'10' PERMANENT EASEMENT, TYP10'SEE NOTE 1
SILT FENCE, TYP.
C-31-0400 FIBER FILTRATION TUBE
C-31-0424
LIMITS OF DISTURBANCE,
SEE NOTE 4
TREE PROTECTION
FENCE, TYP.
C-31-0404
SEE NOTE 3
190 LF RESTRAINED JOINT
SEE NOTE 3
245
250
255
260
265
270
245
250
255
260
265
270
7+00 8+00 9+00 10+00 11+00
260
265
270
275
280
285
260
265
270
275
280
285
11+00 12+00 13+00 14+0020" 22.5° BENDSTA 7+6320" 22.5° BENDSTA 8+4320" 45° BENDSTA 8+9920" 45° BENDSTA 9+30OHE
OHE
OHE
OHEOHEOHE
OHE
OHE
OHE
OHE
OHE
OHE
INV= 260.9'INV= 261.0'INV= 261.1'INV= 261.2'INV= 261.2'87" X 137" CMP87" X 137" CMP87" X 137" CMPINV= 261.2'TBM
BENCHTIE SET IN 12" POPLAR
NAVD '88 ELEV: 277.25'
W W W W W W W W W W W W W
W
FM FM FM FM FM
FMFM FM FMFM FM FM FM FM FM FM FM FMFMFMFMFMFMFMFMFMFM
7+00
8+0
0
9+0010+00 11+00 12+00
13+00
14+00
27
0 275280275270
270
26
5
2
6
5
STA 7+63
20" 22.5° BEND STA 9+30
20" 45° BEND
STA 8+99
20" 45° BEND
STA 8+43
20" 22.5° BEND
265
FFT FFTFFT
FFT
FFT FFT FFT FFT FFT FFT
FFT
FFT FFT FFT FFT FFT FFT FFT FFT FFT FFT FFT
LOD LOD LOD LOD LOD
LO
D
LO
D
LO
D
LO
D
LO
D
LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
FFT FFT
FFT
FFT
FFT
FFT FFT
FFT
FFT
FFT
FFT FFTFFT
FFT FFT FFT FFT FFT FFT FFT FFT FFT
FFT FFT FFT FFT FFT FFT FFT FFT FFT FFT FFT
PLAN
1" = 30'
PROFILE
H: 1" = 30' V: 1" = 3'PLOT DATE: 1/19/2021 12:42 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C2 Saved by ENG Save date: 11/12/2020 11:57 AMSNOW HILL ROAD
FORCEMAIN
31453-000
01
JANUARY 2021B. PORTER
IF THIS BAR DOES NOT
MEASURE 1" THEN DRAWING
IS NOT TO FULL SCALE
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT
ENGINEER:
REV ISSUED FOR DATE BY
0 1"1/2"
CONTRACT NO.:
HAZEN NO.:
DATE:
DRAWING
NUMBER:HAZEN AND SAWYER
4011 WESTCHASE BOULEVARD, SUITE 500
RALEIGH, NORTH CAROLINA 27607
LICENSE NO.: C-0381
WHARTON-SMITH, INC.
5601 77 CENTER DRIVE #120, CHARLOTTE,
NORTH CAROLINA 28217
90% SUBMITTAL - NOT FOR CONSTRUCTION
N. JOHNSON
E. NG
C2
20" FORCE MAIN
PLAN AND PROFILE
STATION 7+00 TO 14+00
B. PORTERMATCHLINE - STA 7+00 SEE SHEET C1MATCHLINE - STA 14+00 SEE SHEET C3PERMANENT EASEMENT, TYP
SNOW HILL RD (SR 1631)
20" FORCE MAIN, TYP
WETLAND, TYP
EX TEL, TYP
EX 30" DIP, TYP
EX 12" FM, TYP
10'TYPUNITED STATES OF AMERICA
ATTN: US ARMY CORPS OF ENGINEERS
D.B. 1057, PG. 659
ADDRESS: 2324 SNOW HILL ROAD
EXISTING GRADE, TYP
20" PC 350 DIP FORCE MAIN, TYP
UNITED STATES OF AMERICA
ATTN: US ARMY CORPS OF ENGINEERS
D.B. 1057, PG. 659
ADDRESS: 2324 SNOW HILL ROAD
SECRETARY DEPARTMENT OF EDUCATION
UNITED STATES OF AMERICA
D.B. 945, PG. 631
ADDRESS: 2501 SNOW HILL ROAD
CITY OF DURHAM
D.B. 2603, PG. 577
P.B.94, PG. 11
ADDRESS: 2414 SNOW HILL ROAD
EXISTING GRADE, TYP
20" PC 350 DIP FORCE MAIN, TYP
SUSAN WHITSON WEINBERG REVOCABLE TRUST
D.B. 6536, PG. 294
P.B. 128, PG. 15
P.B. 143, PG. 13
ADDRESS: 2617 SNOW HILL ROAD
CL CREEK10'FIBER FILTRATION TUBE, TYP.
C-31-0424
CABIN BRANCH
LIMITS OF DISTURBANCE,
SEE NOTE 1
216 LF RESTRAINED JOINT
NOTES:
1.LOD LINE IS NOT SHOWN CONTINUOUSLY FOR
CLARITY. THE LIMITS OF DISTURBANCE SHALL BE
COINCIDENT WITH THE PROPOSED EASEMENT LIMITS
AND PROPOSED TEMPORARY EASEMENT LIMITS
WHERE NO LOD IS SHOWN.
2.THE LIMITS OF DISTURBANCE SHALL NOT EXCEED 30'
IN WIDTH WHILE WITHIN REGULATORY STREAM
BUFFERS.
STREAM CROSSING BYPASS
C-35-0700
CHANNEL LINING, TYP.
C-31-0470
STREAM BUFFERS, TYP.
SEE NOTE 2
X4' WOOD
GRAVELGRAVELOHE OHE
OHE OHE OHE OHE
OH
E
OH
E
OH
E
OH
E
OHE OHE OHE OHE
GRAVELGRAVELINV= 292.4'24" RCPINV= 288.3'30" RCPINV= 285.6'INV= 290.7'15" RCPINV= 320.0'INV= 321.9'W
W W
W
W
FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM14+00 15+00 16+00 17+00
18+00 19+00 20+00 21+00
28
0
2
8
5
285
290295295290300305310312315320325330
330
335
3253203153
1
0305300
STA 15+06
20" 45° BEND
STA 15+15
20" 45° BEND
STA 15+35
20" 45° BEND
STA 15+23
20" 45° BEND
STA 14+98
2" AIR VACUUM VALVE
STA 19+00
3" VACUUM BREAKER VALVE
FFT FFT FFT FFT FFT
FFT
FFT FFT FFT FFT FFT
LOD LOD LOD LOD LOD LOD LOD LOD
LOD
LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
FFT FFT FFT FFT FFT FFT FFT FFT FFT FFTSTREAM E270
275
280
285
290
295
300
270
275
280
285
290
295
300
14+00 15+00 16+00 17+00
280
285
290
295
300
305
310
280
285
290
295
300
305
310
17+00 18+00
295
300
305
310
315
320
325
295
300
305
310
315
320
325
18+00 19+00 20+00
305
310
315
320
325
330
335
305
310
315
320
325
330
335
20+00 21+0020" 45° BENDSTA 15+0620" 45° BENDSTA 15+1520" 45° BENDSTA 15+2320" 45° BENDSTA 15+352" AIR VACUUM VALVESTA 14+983" VACUUM BREAKER VALVESTA 19+00PLOT DATE: 1/19/2021 12:43 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C3 Saved by AMARCH Save date: 11/9/2020 11:12 AMSNOW HILL ROAD
FORCEMAIN
31453-000
01
JANUARY 2021B. PORTER
IF THIS BAR DOES NOT
MEASURE 1" THEN DRAWING
IS NOT TO FULL SCALE
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT
ENGINEER:
REV ISSUED FOR DATE BY
0 1"1/2"
CONTRACT NO.:
HAZEN NO.:
DATE:
DRAWING
NUMBER:HAZEN AND SAWYER
4011 WESTCHASE BOULEVARD, SUITE 500
RALEIGH, NORTH CAROLINA 27607
LICENSE NO.: C-0381
WHARTON-SMITH, INC.
5601 77 CENTER DRIVE #120, CHARLOTTE,
NORTH CAROLINA 28217
90% SUBMITTAL - NOT FOR CONSTRUCTION
N. JOHNSON
E. NG
C3
20" FORCE MAIN
PLAN AND PROFILE
STATION 14+00 TO 21+00
----
SCALE: 1" = 30'
PLAN
NOTES:
1.REMOVE AND REPLACE EXISTING FENCE AT NEW
PERMANENT EASEMENT LINE.
2.LOD LINE IS NOT SHOWN CONTINUOUSLY FOR
CLARITY. THE LIMITS OF DISTURBANCE SHALL BE
COINCIDENT WITH THE PROPOSED EASEMENT LIMITS
AND PROPOSED TEMPORARY EASEMENT LIMITS
WHERE NO LOD IS SHOWN.
3.THE LIMITS OF DISTURBANCE SHALL NOT EXCEED 30'
IN WIDTH WHILE WITHIN REGULATORY STREAM
BUFFERS.MATCHLINESTA 14+00 SEE SHEET C2MATCHLINESTA 21+00 SEE SHEET C410' PERMANENT EASEMENT
SNOW HILL RD (SR 1631)
20" FORCE MAIN, TYP
PROFILE
H: 1" = 30' V: 1" = 3'
EX TEL, TYP
EX 30" DIP, TYP
EX 12" FM, TYP
10'TYPSUSAN WHITSON WEINBERG REVOCABLE TRUST
D.B. 6536, PG. 294
P.B. 128, PG. 15
P.B. 143, PG. 13
ADDRESS: 2617 SNOW HILL ROAD
JOHN S TUTEN AND WIFE, PATRICIA F. TUTEN
D.B. 1040, PG. 95
P.B. 97, PG. 13
ADDRESS: 2600 SNOW HILL ROAD 10'EXISTING GRADE, TYP
20" PC 350 DIP FORCE MAIN, TYP
EXISTING GRADE, TYP
20" PC 350 DIP FORCE MAIN, TYPMIN 3.5' COVER
CLEAN WATER
DIVERSION, TYP.
C-31-0440
LIMITS OF DISTURBANCE,
SEE NOTE 2
STREAM CROSSING BYPASS
SEE NOTE 1
156 LF RESTRAINED JOINT
FIBER FILTRATION TUBE, TYP.
C-31-0424
FIBER FILTRATION TUBE, TYP.
C-31-0424
STREAM BUFFER, TYP.
SEE NOTE 3
C-35-0700
CHANNEL LINING, TYP.
C-31-0470
315
320
325
330
335
340
315
320
325
330
335
340
21+00 22+00 23+00
325
330
335
340
345
350
325
330
335
340
345
350
23+00 24+00 25+00 26+00 27+00 28+0020" 45° BENDSTA 24+5420" 45° BENDSTA 24+7820" 45° BENDSTA 24+9420" 45° BENDSTA 25+186" BIAS AIR VACUUM VALVESTA 25+502" BIAS AIR VACUUM VALVESTA 21+30X X X X
4' WOOD
SOILOHE
OHE
OHE
OHE
OHE
OHEOHE OHE OHE OHE OHE OHE OHE
15" RCPINV= 320.0'INV= 321.9'ARV MANHOLE
RIM = 343.0'
TOP OF ARV = 335.8'+/-
TOP OF 12" DIP = 333.3'+/-
MANHOLE FULL OF WATER
CANNOT SEE PIPE
W
W
W
W
W W W W W
W
W
FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM
UGECATVCATVTFM FM FM FM FM FM FM FM FM FM FM FM FM
21+00 22+00 23+00 24+00
25+0026+00 27+00 28+00
340340 340330330325325
335335STA 24+54
20" 45° BEND
STA 24+78
20" 45° BEND
STA 24+94
20" 45° BEND
STA 25+18
20" 45° BEND
SF SF SF SF SF SF SF SF SF SF SF SF
SF SF SF SF SF SF SF
LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
CONC
RETE
STA 21+30
2" BIAS AIR VACUUM VALVE
STA 25+50
6" BIAS AIR VACUUM VALVE
PLAN
1" = 30'
PROFILE
H: 1" = 30' V: 1" = 3'PLOT DATE: 1/19/2021 12:43 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C4 Saved by ENG Save date: 11/12/2020 12:17 PMSNOW HILL ROAD
FORCEMAIN
31453-000
01
JANUARY 2021B. PORTER
IF THIS BAR DOES NOT
MEASURE 1" THEN DRAWING
IS NOT TO FULL SCALE
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT
ENGINEER:
REV ISSUED FOR DATE BY
0 1"1/2"
CONTRACT NO.:
HAZEN NO.:
DATE:
DRAWING
NUMBER:HAZEN AND SAWYER
4011 WESTCHASE BOULEVARD, SUITE 500
RALEIGH, NORTH CAROLINA 27607
LICENSE NO.: C-0381
WHARTON-SMITH, INC.
5601 77 CENTER DRIVE #120, CHARLOTTE,
NORTH CAROLINA 28217
90% SUBMITTAL - NOT FOR CONSTRUCTION
N. JOHNSON
E. NG
C4
20" FORCE MAIN
PLAN AND PROFILE
STATION 21+00 TO 28+00
B. PORTER
NOTES:
1.CONTRACTOR SHALL VERIFY OD OF EXISTING ARV
MH AHEAD OF PIPE INSTALLATION AND DEFLECT
NEW FM AS NECESSARY AROUND EXISTING MH.
AFTER THE NEW 20" FORCE MAIN IS IN SERVICE,
ABANDON EXISTING ARV MH IN PLACE. RETURN ARV
AND VALVES TO THE CITY OF DURHAM.
2.REMOVE AND REPLACE EXISTING FENCE AT NEW
PERMANENT EASEMENT LINE.
3.LOD LINE IS NOT SHOWN CONTINUOUSLY FOR
CLARITY. THE LIMITS OF DISTURBANCE SHALL BE
COINCIDENT WITH THE PROPOSED EASEMENT LIMITS
AND PROPOSED TEMPORARY EASEMENT LIMITS
WHERE NO LOD IS SHOWN.MATCHLINE - STA 21+00 SEE SHEET C3MATCHLINE - STA 28+00 SEE SHEET C510' PERMANENT EASEMENT, TYP
SNOW HILL RD (SR 1631)
20" FORCE MAIN, TYP10'EX TEL, TYP
EX 30" DIP, TYP
EX 12" FM, TYP
10'JEREMY T. FREEMAN AND WIFE, MIRANDA L. FREEMAN
D.B. 6377, PG. 690
P.B. 94, PG. 33
P.B. 148, PG. 45
ADDRESS: 2806 SNOW HILL ROAD
CHARLES E. SOUTHALL, JR.
D.B. 7182, PG. 484
P.B. 93, PG. 89
ADDRESS: 2818 SNOW HILL ROAD
DANIEL T. GLOSSON AND WIFE,
PATRICIA A. GLOSSON
D.B. 2823, PG. 979
P.B. 148, PG. 45
ADDRESS: 2804 SNOW HILL ROAD
BRUCE F. PHILLIPS AND WIFE,
BARBARA H. PHILLIPS
D.B. 2876, PG. 962
P.B. 148, PG. 45
ADDRESS: 2802 SNOW HILL ROAD
SUSAN WHITSON WEINBERG REVOCABLE TRUST
D.B. 6536, PG. 294
P.B. 128, PG. 15
P.B. 143, PG. 13
ADDRESS: 2803 SNOW HILL ROAD
10'EXISTING GRADE, TYP
20" PC 350 DIP FORCE MAIN, TYP
MIN 3.5' COVER
EXISTING GRADE, TYP
20" PC 350 DIP FORCE MAIN, TYP
SILT FENCE, TYP.
C-31-0400
LIMITS OF DISTURBANCE,
SEE NOTE 3
SEE NOTE 1
SEE NOTE 2
165 LF RESTRAINED JOINT
CLEAN WATER
DIVERSION, TYP.
C-31-0440
FIBER FILTRATION TUBE, TYP.
C-31-0424
CHANNEL LINING, TYP.
C-31-0470
315
320
325
330
335
340
315
320
325
330
335
340
28+00 29+00 30+00 31+00 32+00
310
315
320
325
330
335
310
315
320
325
330
335
32+00 33+00 34+00 35+0020" 45° BENDSTA 31+2220" 45° BENDSTA 31+7220" 45° BENDSTA 31+5020" 45° BENDSTA 31+42X X X X X X
XXXXXXXXXXXXXXXXX X X X X
4' WOODGATE
3.5' WOOD3.5' WOOD3.5' WOOD3.5' WOOD
4' WOOD
4' WOOD4' WIRE
GRAVELOHEOHEOHE
OHE
OHE
OHE OHE OHE OHE OHE
OHE OHE OHE OHE OHE
GRAVELGRAVELGRAVELINV= 331.9'15" RCP INV= 331.0'INV= 320.8'15" RCP INV= 319.5'W
W
W W W
W
W
W W W W W W
UGE TFM
FM
FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM
TBM
BENCHTIE SET IN 12" OAK
NAVD '88 ELEV: 318.92'
28+00
29+00 30+00 31+00 32+00 33+00 34+00 35+00
STA 31+72
20" 45° BEND
STA 31+50
20" 45° BEND
STA 31+42
20" 45° BEND
STA 31+22
20" 45° BEND
335
3
4
0
335330
330
325 3203
2
0 320320325SF/TPF SF/TPF SF/TPF
S
F
SF SFSF SF SF SF SF SF SF SF
SF
SF SF
SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF
LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
PLAN
1" = 30'
PROFILE
H: 1" = 30' V: 1" = 3'PLOT DATE: 1/19/2021 12:44 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C5 Saved by ENG Save date: 11/12/2020 2:18 PMSNOW HILL ROAD
FORCEMAIN
31453-000
01
JANUARY 2021B. PORTER
IF THIS BAR DOES NOT
MEASURE 1" THEN DRAWING
IS NOT TO FULL SCALE
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT
ENGINEER:
REV ISSUED FOR DATE BY
0 1"1/2"
CONTRACT NO.:
HAZEN NO.:
DATE:
DRAWING
NUMBER:HAZEN AND SAWYER
4011 WESTCHASE BOULEVARD, SUITE 500
RALEIGH, NORTH CAROLINA 27607
LICENSE NO.: C-0381
WHARTON-SMITH, INC.
5601 77 CENTER DRIVE #120, CHARLOTTE,
NORTH CAROLINA 28217
90% SUBMITTAL - NOT FOR CONSTRUCTION
N. JOHNSON
E. NG
C5
20" FORCE MAIN
PLAN AND PROFILE
STATION 28+00 TO 35+00
B. PORTER
NOTES:
1.REMOVE AND REPLACE EXISTING FENCE AND GATE
AT NEW PERMANENT EASEMENT LINE.
2.LOD LINE IS NOT SHOWN CONTINUOUSLY FOR
CLARITY. THE LIMITS OF DISTURBANCE SHALL BE
COINCIDENT WITH THE PROPOSED EASEMENT LIMITS
AND PROPOSED TEMPORARY EASEMENT LIMITS
WHERE NO LOD IS SHOWN.MATCHLINE - STA 28+00 SEE SHEET C4MATCHLINE - STA 35+00 SEE SHEET C610' PERMANENT EASEMENT, TYP
SNOW HILL RD (SR 1631)
20" FORCE MAIN, TYP10'EX TEL, TYP
EX 30" DIP, TYP
EX 12" FM, TYP
10'SOUTHALL ROSE JONES
D.B. 6003, PG. 328
P.B. 143, PG. 13
ADDRESS: 2807 SNOW HILL ROAD
CHARLES E. SOUTHALL, SR., & CHARLES E. SOUTHALL, JR.
D.B. 7182, PG. 488
P.B. 93, PG. 89
ADDRESS: 2820 SNOW HILL ROAD
REBECCA S. OLBRYCH, TRUSTEE
D.B. 8373, PG. 824
P.B. 135, PG. 101
P.B. 75, PG. 29
ADDRESS: 2910 SNOW HILL ROAD
JESSICA L. GOODWIN & RICHARD
E. GOODWIN
D.B. 8248, PG. 680
P.B. 70, PG. 69
ADDRESS: 3008 SNOW HILL ROADREBECCA GREEN SERCY
D.B. 1508, PG. 423
P.B. 135, PG. 101
ADDRESS: 2908 SNOW HILL ROAD
VIRGINIA L. HARRIS
D.B. 3428, PG. 317
ADDRESS: 2917 SNOW HILL ROAD
JARED RAY COATES & JODIE S. COATES
D.B. 2335, PG. 456
P.B. 135, PG. 101
ADDRESS: 2918 SNOW HILL ROAD
EXISTING GRADE, TYP
20" PC 350 DIP FORCE MAIN, TYP
20" PC 350 DIP FORCE MAIN, TYP
EXISTING GRADE, TYP
SILT FENCE, TYP.
LIMITS OF DISTURBANCE,
SEE NOTE 2
TREE PROTECTION
FENCE, TYP.
C-31-0404
NOTE 1, TYP
165 LF RESTRAINED JOINT
FIBER FILTRATION TUBE, TYP.
C-31-0424
CHANNEL LINING, TYP.
C-31-0470
C-31-0400
295
300
305
310
315
320
295
300
305
310
315
320
35+00 36+00 37+00
285
290
295
300
305
310
285
290
295
300
305
310
37+00 38+00
275
280
285
290
295
300
275
280
285
290
295
300
38+00 39+00 40+00
260
265
270
275
280
285
260
265
270
275
280
285
40+00 41+00 42+00
X X X X X X X X X X X X X X X X X X
X
X
X
GATE
4' WIRE
4' WIRE
GRAVELGRAVEL4' WIRE
OHE
OHEOHEOHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE
GRAVELGRAVEL4' WIRE
INV= 270.2'72" CMPINV= 301.6'18" RCP INV= 300.5'INV= 302.1'15" CMP INV= 301.8'W W W W W W W W W W W W
W
FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM
35+00 36+00 37+00 38+00 39+00 40+00 41+00 42+00
320
315 310 305 300305310315300295295290285280275
275 280285290275305SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF
TPF TPF TPF TPF TPF TPF TPF
LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODSTREAM HPLAN
1" = 30'
PROFILE
H: 1" = 30' V: 1" = 3'PLOT DATE: 1/19/2021 12:45 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C6 Saved by ENG Save date: 11/12/2020 2:19 PMSNOW HILL ROAD
FORCEMAIN
31453-000
01
JANUARY 2021B. PORTER
IF THIS BAR DOES NOT
MEASURE 1" THEN DRAWING
IS NOT TO FULL SCALE
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT
ENGINEER:
REV ISSUED FOR DATE BY
0 1"1/2"
CONTRACT NO.:
HAZEN NO.:
DATE:
DRAWING
NUMBER:HAZEN AND SAWYER
4011 WESTCHASE BOULEVARD, SUITE 500
RALEIGH, NORTH CAROLINA 27607
LICENSE NO.: C-0381
WHARTON-SMITH, INC.
5601 77 CENTER DRIVE #120, CHARLOTTE,
NORTH CAROLINA 28217
90% SUBMITTAL - NOT FOR CONSTRUCTION
N. JOHNSON
E. NG
C6
20" FORCE MAIN
PLAN AND PROFILE
STATION 35+00 TO 42+00
B. PORTERMATCHLINE - STA 35+00 SEE SHEET C5MATCHLINE - STA 42+00 SEE SHEET C710' PERMANENT EASEMENT, TYP
SNOW HILL RD (SR 1631)
20" FORCE MAIN, TYP
EX 30" DIP, TYP
EX 12" FM, TYP
10'JESSICA L. GOODWIN & RICHARD
E. GOODWIN
D.B. 8248, PG. 680
P.B. 70, PG. 69
ADDRESS: 3008 SNOW HILL ROAD
EXISTING GRADE, TYP
20" PC 350 DIP FORCE MAIN, TYP
SCOTTIE DOUGLAS McFARLAND
215, PG. 458D.B.
P.B. 14, PG. 96
P.B. 5A, PG. 65
ADDRESS: 2132 INFINITY ROAD
EXISTING GRADE, TYP
20"PC 350 DIP FORCE MAIN, TYP
MIN 4' COVER
SILT FENCE, TYP.
LIMITS OF DISTURBANCE,
SEE NOTE 1
CHANNEL LINING, TYP.
TREE PROTECTION
FENCE, TYP.
C-31-0404
NOTES:
1.LOD LINE IS NOT SHOWN CONTINUOUSLY FOR
CLARITY. THE LIMITS OF DISTURBANCE SHALL BE
COINCIDENT WITH THE PROPOSED EASEMENT LIMITS
AND PROPOSED TEMPORARY EASEMENT LIMITS
WHERE NO LOD IS SHOWN.
2.THE LIMITS OF DISTURBANCE SHALL NOT EXCEED 30'
IN WIDTH WHILE WITHIN REGULATORY STREAM
BUFFERS.
STREAM BUFFER, TYP
SEE NOTE 2POND BUFFER
FIBER FILTRATION TUBE, TYP.
C-31-0424
C-31-0400
C-31-0470
260
265
270
275
280
285
260
265
270
275
280
285
42+00 43+00 44+00
270
275
280
285
290
295
270
275
280
285
290
295
44+00 45+00 46+00 47+00 48+00 49+00
X
X X X
X X X X X X X
XXX
X
X
X
X
X
X X X X X X X X X X4' WIRE4' BARBE
D
W
I
R
E
4" BARBED
W
I
R
E
CABLEGRAVEL4' WIRE
4' WIRE 4' WIRE
GRAVELGRAVELOHE
OHE
OHE
OHE
OHE
OHEOHEOHEOHE
OHE
OHE
OHE
OHEOHEOHEOHEOHEOHE
OHE
OHE
OHE
OHEGRAVEL4' WIRE
4' WIRE 4' WIRE
GRAVELGRAVEL12"RCP
INV= 270.2'72" CMPINV= 269.6'INV= 285.9'INV= 285.7'ARV MANHOLERIM = 290.2'TOP OF 12" DIP = 284.9'+/-MANHOLE FULL OF WATERCANNOT SEE PIPE2 ST
O
R
Y
WO
O
D
B
A
R
N
(ABA
N
D
O
N
E
D
)
AB
A
N
D
.
SH
E
D 18" HICKORY24" PECANW
W
W
W
W
W
W W
W
W
W
W
W
W
WWWW W W W W
GASFM
FM
FM
FM
FM
FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM
FM
FM
FM
X
X X X
X X X X X X X
XXX
X
X
X
X
X
X X X X X X X X X X4' WIRE4' BARBE
D
W
I
R
E
4" BARBED
W
I
R
E
CABLEGRAVEL4' WIRE
4' WIRE 4' WIRE
GRAVELGRAVELOHE
OHE
OHE
OHE
OHE
OHEOHEOHEOHE
OHE
OHE
OHE
OHEOHEOHEOHEOHEOHE
OHE
OHE
OHE
OHEGRAVEL4' WIRE
4' WIRE 4' WIRE
GRAVELGRAVEL12"RCP
INV= 270.2'72" CMPINV= 269.6'INV= 285.9'INV= 285.7'ARV MANHOLERIM = 290.2'TOP OF 12" DIP = 284.9'+/-MANHOLE FULL OF WATERCANNOT SEE PIPE2 ST
O
R
Y
WO
O
D
B
A
R
N
(ABA
N
D
O
N
E
D
)
AB
A
N
D
.
SH
E
D 18" HICKORY24" PECANW
W
W
W
W
W
W W
W
W
W
W
W
W
WWWW W W W W
GASFM
FM
FM
FM
FM
FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM
FM
FM
FM42+00
43+00
44+00 45+00
46+00 47+00 48+00
49+00
290
285285275280285285
290290290290
290280
SF SF SF SF
TPF
TPF TPF TPF TPF TPF TPF TPF TPF TPF TPF TPF TPF TPF TPF TPF
LOD
LOD
LOD
LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
L
O
D
LODLODLOD
LOD
LOD LOD LOD LOD LOD LOD LOD LODSTREAM HSTA 46+00
20" PLUG VALVE
PLAN
1" = 30'
PROFILE
H: 1" = 30' V: 1" = 3'PLOT DATE: 1/19/2021 12:45 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C7 Saved by ENG Save date: 11/12/2020 2:20 PMSNOW HILL ROAD
FORCEMAIN
31453-000
01
JANUARY 2021B. PORTER
IF THIS BAR DOES NOT
MEASURE 1" THEN DRAWING
IS NOT TO FULL SCALE
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT
ENGINEER:
REV ISSUED FOR DATE BY
0 1"1/2"
CONTRACT NO.:
HAZEN NO.:
DATE:
DRAWING
NUMBER:HAZEN AND SAWYER
4011 WESTCHASE BOULEVARD, SUITE 500
RALEIGH, NORTH CAROLINA 27607
LICENSE NO.: C-0381
WHARTON-SMITH, INC.
5601 77 CENTER DRIVE #120, CHARLOTTE,
NORTH CAROLINA 28217
90% SUBMITTAL - NOT FOR CONSTRUCTION
N. JOHNSON
E. NG
C7
20" FORCE MAIN
PLAN AND PROFILE
STATION 42+00 TO 49+00
B. PORTER
NOTES:
1.ELEVATION OF UTILITIES SHOWN IN THE PROFILE
ARE APPROXIMATE.
2.REMOVE AND REPLACE EXISTING FENCE AND GATES
AT THE NEW PERMANENT EASEMENT LINE.
3.LOD LINE IS NOT SHOWN CONTINUOUSLY FOR
CLARITY. THE LIMITS OF DISTURBANCE SHALL BE
COINCIDENT WITH THE PROPOSED EASEMENT LIMITS
AND PROPOSED TEMPORARY EASEMENT LIMITS
WHERE NO LOD IS SHOWN.
4.THE LIMITS OF DISTURBANCE SHALL NOT EXCEED 30'
IN WIDTH WHILE WITHIN REGULATORY STREAM
BUFFERS.MATCHLINE - STA 42+00 SEE SHEET C6MATCHLINE - STA 49+00 SEE SHEET C820' PERMANENT EASEMENT, TYP
SNOW HILL RD (SR 1631)
20" FORCE MAIN, TYP
INFINITY RD (SR 1639)20'EX TEL, TYP
EX 30" DIP, TYP
EX 12" FM, TYP
EX 30" W
EL 285.73±
EX 8" GASEX 30" WATEREXISTING GRADE, TYP
20" PC 350 DIP FORCE MAIN, TYP
SCOTTIE DOUGLAS McFARLAND
D.B. 215, PG. 458
P.B. 14, PG. 96
P.B. 5A, PG. 65
ADDRESS: 2132 INFINITY ROAD
SCOTTIE DOUGLAS McFARLAND
D.B. 215, PG. 458
P.B. 14, PG. 96
P.B. 5A, PG. 65
ADDRESS: 2132 INFINITY ROAD
91 LF OF 36" STEEL CASING PIPE
MINIMUM THICKNESS 0.25"
INSTALLED BY TRENCHLESS METHOD
EX TEL
EX ARV MH
RIM = 290.2'
TOP OF 12" DIP = 284.9'±
MANHOLE FULL OF WATER
CANNOT SEE PIPE
91 LF OF 36" STEEL CASING PIPE
MINIMUM THICKNESS 0.25"
INSTALLED BY TRENCHLESS METHOD
MIN 3'
SILT FENCE. TYP.
C-31-0400
LIMITS OF DISTURBANCE,
SEE NOTE 3
FIBER FILTRATION TUBE, TYP.
C-31-0424 TREE PROTECTION
FENCE, TYP.
C-31-0404
MIN 4' COVER
SEE NOTE 2
607 LF RESTRAINED JOINT
STREAM CROSSING BYPASS
C-35-0700
STREAM BUFFER, TYP.
SEE NOTE 4
CLEAN WATER
DIVERSION, TYP.
C-31-0440
CHANNEL LINING, TYP.
C-31-0470
270
275
280
285
290
295
270
275
280
285
290
295
49+00 50+00 51+00 52+00 53+00 54+00 55+00 56+0020" 45° BENDSTA 49+1320" 45° BENDSTA 50+6420" 22.5° BENDSTA 50+8720" 45° BENDSTA 49+01XXXXXXXXX X X
4' WIRE3' BARBED WIRECABLE 4' WIRE CABLE
GRAVELOHE OHE OHE OHE OHE
GRAVEL12"CMP12"RCP INV= 282.4'INV= 282.7'INV= 285.9'INV= 285.7'18" HICKORYW
W W W W
W W W
W
FM FM FM FM FM FM FM FM
FMFMFMFMFMXXXXXXXXX X X
4' WIRE3' BARBED WIRECABLE 4' WIRE CABLE
GRAVELOHE OHE OHE OHE OHE
GRAVEL12"CMP12"RCP INV= 282.4'INV= 282.7'INV= 285.9'INV= 285.7'18" HICKORYW
W W W W
W W W
W
FM FM FM FM FM FM FM FM
FMFMFMFMFMTCETCE49+00
50+00
51+0052+00STA 49+01
20" 45° BEND
STA 49+13
20" 45° BEND
STA 50+64
20" 45° BEND
STA 50+87
20" 22.5° BEND
290
285
SF/TPFSF/TPFSF/TPFSF/TPFSF/TPFTCETCETPF TPF TPF TPF
LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
LODLODLODLODLODLODLODLODLODLODX X X X X X X X X
X
X X
3' BARBED WIRE
FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM
TBM
BENCHTIE SET IN 15" ELM
NAVD '88 ELEV: 289.72'
FM
X X X X X X X X X
X
X X
3' BARBED WIRE
FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM
TBM
BENCHTIE SET IN 15" ELM
NAVD '88 ELEV: 289.72'
FM
TCE TCE TCE TCE TCE TCE TCE
52+00 53+00 54+00 55+00 56+00
290 290285 28
5
SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF
S
F
/
T
P
F
SF/TPF SF/TPF SF/TPF
TCE TCE TCE TCE TCE TCE TCE
LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
L
O
D
L
O
D
LOD LOD LOD LOD LOD LOD
LOD
LOD LOD LOD LOD LOD LOD LOD
PLAN
1" = 30'
PROFILE
H: 1" = 30' V: 1" = 3'PLOT DATE: 1/28/2021 11:59 AM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C8 Saved by AMARCH Save date: 1/18/2021 11:13 AMSNOW HILL ROAD
FORCEMAIN
31453-000
01
JANUARY 2021B. PORTER
IF THIS BAR DOES NOT
MEASURE 1" THEN DRAWING
IS NOT TO FULL SCALE
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT
ENGINEER:
REV ISSUED FOR DATE BY
0 1"1/2"
CONTRACT NO.:
HAZEN NO.:
DATE:
DRAWING
NUMBER:HAZEN AND SAWYER
4011 WESTCHASE BOULEVARD, SUITE 500
RALEIGH, NORTH CAROLINA 27607
LICENSE NO.: C-0381
WHARTON-SMITH, INC.
5601 77 CENTER DRIVE #120, CHARLOTTE,
NORTH CAROLINA 28217
90% SUBMITTAL - NOT FOR CONSTRUCTION
N. JOHNSON
E. NG
C8
20" FORCE MAIN
PLAN AND PROFILE
STATION 49+00 TO 56+00
B. PORTERMATCHLINE - STA 49+00 SEE SHEET C7MATCHLINE - STA 56+00 SEE SHEET C9MATCHLINE - STA 52+00 SEE THIS SHEET
MATCHLINE - STA 52+00 SEE THIS SHEETPLAN
1" = 30'
20' PERMANENT EASEMENT, TYP
SNOW HILL RD (SR 1631)
20" FORCE MAIN, TYP
25'25'25' TEMPORARY CONSTRUCTION
EASEMENT, TYP
20" FORCE MAIN, TYP
15'
40'
EXISTING 40' EASEMENT, TYP 40'25' TEMPORARY CONSTRUCTION
EASEMENT, TYP
EXISTING 40' EASEMENT, TYP
15'EX 12" FORCE MAIN, TYP
EX 12" FM, TYP
10'SCOTTIE DOUGLAS McFARLAND
D.B. 215, PG. 458
P.B. 14, PG. 96
P.B. 5A, PG. 65
ADDRESS: 2132 INFINITY ROAD
AGNES S. CRIST & ANAV S. MAGDA
ESTATE FILE NO. 1989-E-469
P.B. 82, PG. 47
ADDRESS: 3314 SNOW HILL ROAD
SCOTTIE DOUGLAS McFARLAND
D.B. 215, PG. 458
P.B. 14, PG. 96
P.B. 5A, PG. 65
ADDRESS: 2132 INFINITY ROAD
AGNES S. CRIST & ANAV S. MAGDA
ESTATE FILE NO. 1989-E-469
P.B. 82, PG. 47
P.B. 77, PG. 33
ADDRESS: 3326 SNOW VALLEY ROAD
EXISTING GRADE, TYP
20" PC 350 DIP FORCE MAIN, TYP
MIN 3.5' COVER
SILT FENCE, TYP.
C-31-0400
LIMITS OF DISTURBANCE,
SEE NOTE 2
TREE PROTECTION
FENCE, TYP.
C-31-0404
NOTES:
1.REMOVE AND REPLACE EXISTING FENCE AND GATE
AT NEW PERMANENT EASEMENT LINE ALONG SNOW
HILL. FENCE ALONG EXISTING EASEMENT SHALL
REMAIN.
2.LOD LINE IS NOT SHOWN CONTINUOUSLY FOR
CLARITY. THE LIMITS OF DISTURBANCE SHALL BE
COINCIDENT WITH THE PROPOSED EASEMENT LIMITS
AND PROPOSED TEMPORARY EASEMENT LIMITS
WHERE NO LOD IS SHOWN.
2.THE LIMITS OF DISTURBANCE SHALL NOT EXCEED 30'
IN WIDTH WHILE CROSSING STREAM BUFFERS.
SEE NOTE 1
607 LF RESTRAINED JOINT
TEMPORARY CONSTRUCTION
ENTRANCE
C-31-0490
FIBER FILTRATION TUBE, TYP.
C-31-0424
CHANNEL LINING, TYP.
C-31-0470
STREAM BUFFERS, TYP.
SEE NOTE 3
275
280
285
290
295
300
275
280
285
290
295
300
56+00 57+00 58+00 59+00 60+00 61+00 62+00 63+00
X X X
X
X X X X
X X X X X X X X
X X X
3' BARBED WIRE
3' BARBED WIRE3' BARBED WIRE
3' BARBED WIRESOIL PATHSOIL PATH
FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM
RIP-RAPRIP-RAPX X X
X
X X X X
X X X X X X X X
X X X
3' BARBED WIRE
3' BARBED WIRE3' BARBED WIRE
3' BARBED WIRESOIL PATHSOIL PATH
FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM
RIP-RAPRIP-RAPTCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE
56+00 57+00 58+00 59+00 60+00 61+00 62+00 63+00
2
9
0
2
9
0
28
5
29
0
2
9
0 2902
9
5 295295 295
29
0
SF/TPF SF/TPF SF/TPF SF/TPF
SF/T
P
F
SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF
TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE
LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
LOD
LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
L
O
D
LOD
PLAN
1" = 30'
PROFILE
H: 1" = 30' V: 1" = 3'PLOT DATE: 1/28/2021 11:58 AM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C9 Saved by AMARCH Save date: 1/28/2021 11:56 AMSNOW HILL ROAD
FORCEMAIN
31453-000
01
JANUARY 2021B. PORTER
IF THIS BAR DOES NOT
MEASURE 1" THEN DRAWING
IS NOT TO FULL SCALE
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT
ENGINEER:
REV ISSUED FOR DATE BY
0 1"1/2"
CONTRACT NO.:
HAZEN NO.:
DATE:
DRAWING
NUMBER:HAZEN AND SAWYER
4011 WESTCHASE BOULEVARD, SUITE 500
RALEIGH, NORTH CAROLINA 27607
LICENSE NO.: C-0381
WHARTON-SMITH, INC.
5601 77 CENTER DRIVE #120, CHARLOTTE,
NORTH CAROLINA 28217
90% SUBMITTAL - NOT FOR CONSTRUCTION
N. JOHNSON
E. NG
C9
20" FORCE MAIN
PLAN AND PROFILE
STATION 56+00 TO 63+00
B. PORTERMATCHLINE - STA 56+00 SEE SHEET C8MATCHLINE - STA 63+00 SEE SHEET C1020" FORCE MAIN, TYP
25'40'25' TEMPORARY CONSTRUCTION
EASEMENT, TYP
EXISTING 40' EASEMENT, TYP
15'EX 12" FORCE MAIN, TYP
SCOTTIE DOUGLAS McFARLAND
D.B. 215, PG 4458
P.B. 14, PG. 96
P.B. 5A, PG. 65
ADDRESS: 2132 INFINITY ROAD
AGNES S. CRIST & ANAV S. MAGDA
ESTATE FILE NO. 1989-E-469
P.B. 82, PG. 47
P.B. 77, PG. 33
ADDRESS: 3326 SNOW VALLEY ROAD AGNES S. CRIST & ANAV S. MAGDA
ESTATE FILE NO. 1989-E-469
P.B. 82, PG. 47
ADDRESS: 2000 SNOW VALLEY ROAD
EXISTING 25' EASEMENT, TYP
EXISTING GRADE, TYP
20" PC 350 DIP FORCE MAIN, TYP
MIN 3.5' COVER
SILT FENCE, TYP.
C-31-0400
LIMITS OF DISTURBANCE,
SEE NOTE 1FIBER FILTRATION TUBE, TYP.
C-31-0424
TREE PROTECTION
FENCE, TYP.
C-31-0404
STREAM CROSSING BYPASS
C-35-0700
NOTES:
1.LOD LINE IS NOT SHOWN CONTINUOUSLY FOR
CLARITY. THE LIMITS OF DISTURBANCE SHALL BE
COINCIDENT WITH THE PROPOSED EASEMENT LIMITS
AND PROPOSED TEMPORARY EASEMENT LIMITS
WHERE NO LOD IS SHOWN.
2.THE LIMITS OF DISTURBANCE SHALL NOT EXCEED 30'
IN WIDTH WHILE CROSSING STREAM BUFFERS.
STREAM BUFFERS, TYP.
SEE NOTE 2
290
295
300
305
310
315
290
295
300
305
310
315
63+00 64+00 65+00 66+00
300
305
310
315
320
325
300
305
310
315
320
325
66+00 67+00 68+00
310
315
320
325
330
335
310
315
320
325
330
335
68+00 69+00 70+003" AIR VACCUM VALVE(FULL SIZED OUTLET)STA 69+743" BIAS AIR VACCUM VALVESTA 65+75X X X X X
X X X X X X
XX X X X X X X
3' BARBED WIREGATE3' BARBED WIRE3' BARBED WIRESOIL PATHSOIL PATHGRAVEL
15" RCP INV= 300.5'16" DIP INV= 300.9'ARV MANHOLERIM = 329.0'TOP OF ARV = 327.0'+/-TOP OF 12" DIP = 323.0'+/-FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM
TBM
BENCHTIE SET IN 8" OAK
NAVD '88 ELEV: 331.85'
X X X X X
X X X X X X
XX X X X X X X
3' BARBED WIREGATE3' BARBED WIRE3' BARBED WIRESOIL PATHSOIL PATHGRAVEL
15" RCP INV= 300.5'16" DIP INV= 300.9'ARV MANHOLERIM = 329.0'TOP OF ARV = 327.0'+/-TOP OF 12" DIP = 323.0'+/-FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM
TBM
BENCHTIE SET IN 8" OAK
NAVD '88 ELEV: 331.85'
TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE
63+00 64+00 65+00 66+00 67+00 68+00 69+00 70+00
300305310315320325
3
3
0
3
3
0
STA 69+74
3" AIR VACCUM VALVE
(FULL SIZED OUTLET)
STA 65+75
3" BIAS AIR VACCUM VALVE
SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF
TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE TCE
LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLOD LODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
330PLAN
1" = 30'
PROFILE
H: 1" = 30' V: 1" = 3'PLOT DATE: 1/19/2021 12:48 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C10 Saved by ENG Save date: 11/12/2020 2:33 PMSNOW HILL ROAD
FORCEMAIN
31453-000
01
JANUARY 2021B. PORTER
IF THIS BAR DOES NOT
MEASURE 1" THEN DRAWING
IS NOT TO FULL SCALE
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT
ENGINEER:
REV ISSUED FOR DATE BY
0 1"1/2"
CONTRACT NO.:
HAZEN NO.:
DATE:
DRAWING
NUMBER:HAZEN AND SAWYER
4011 WESTCHASE BOULEVARD, SUITE 500
RALEIGH, NORTH CAROLINA 27607
LICENSE NO.: C-0381
WHARTON-SMITH, INC.
5601 77 CENTER DRIVE #120, CHARLOTTE,
NORTH CAROLINA 28217
90% SUBMITTAL - NOT FOR CONSTRUCTION
N. JOHNSON
E. NG
C10
20" FORCE MAIN
PLAN AND PROFILE
STATION 63+00 TO 70+00
B. PORTERMATCHLINE - STA 63+00 SEE SHEET C9MATCHLINE - STA 70+00 SEE SHEET C1220" FORCE MAIN, TYP
25'40'25' TEMPORARY CONSTRUCTION
EASEMENT, TYP
EXISTING 40' EASEMENT, TYP
15'EX 12" FORCE MAIN, TYP
SCOTTIE DOUGLAS McFARLAND
D.B. 215, PG 458
P.B. 14, PG. 96
P.B. 5A, PG. 65
ADDRESS: 2132 INFINITY ROAD
AGNES S. CRIST & ANAV S. MAGDA
ESTATE FILE NO. 1989-E-469
P.B. 82, PG. 47
ADDRESS: 2000 SNOW VALLEY ROADSNOW VALLEY
RD
AGNES S. CRIST & ANAV S. MAGDA
ESTATE FILE NO. 1989-E-469
P.B. 82, PG. 47
ADDRESS: 3326 SNOW VALLEY ROAD
EXISTING GRADE, TYP
20" PC 350 DIP FORCE MAIN, TYP
MIN 3.5' COVER
EXISTING GRADE, TYP
20" PC 350 DIP FORCE MAIN, TYP
EX ARV MH
RIM = 329.0'
TOP OF ARV = 327.0'±
TOP OF 12" DIP = 323.0'±
SILT FENCE, TYP.
C-31-0400
LIMITS OF DISTURBANCE,
SEE NOTE 2
TREE PROTECTION
FENCE, TYP.
C-31-0404
NOTES:
1.AFTER THE NEW 20" FORCE MAIN IS IN SERVICE,
ABANDON EXISTING ARV MH IN PLACE. RETURN ARV
AND VALVES TO THE CITY OF DURHAM.
2.LOD LINE IS NOT SHOWN CONTINUOUSLY FOR
CLARITY. THE LIMITS OF DISTURBANCE SHALL BE
COINCIDENT WITH THE PROPOSED EASEMENT LIMITS
AND PROPOSED TEMPORARY EASEMENT LIMITS
WHERE NO LOD IS SHOWN.
SEE NOTE 1
TEMPORARY CONSTRUCTION
ENTRANCE
C-31-0490
305
310
315
320
325
330
305
310
315
320
325
330
70+00 71+00
295
300
305
310
315
320
295
300
305
310
315
320
71+00 72+00
285
290
295
300
305
310
285
290
295
300
305
310
72+00 73+00
275
280
285
290
295
300
275
280
285
290
295
300
73+00 74+00 75+00
260
265
270
275
280
285
260
265
270
275
280
285
75+00 76+00 77+0020" 22.5° BENDSTA 73+9520" 11.25° BENDSTA 76+6720" 22.5° BENDSTA 73+05X XXXXX
X X
X
X X
X
X3' BARBED WIRE
SILT FE
N
C
E
3' BARBED
W
I
R
E SILT FENCESILT FENCE
SILT FENCE
GATE3'
B
A
R
B
E
D
W
I
R
E
SILT
F
E
N
C
E
ASPHALT
SOIL PATH
SOIL PATH
ARV MANHOLERIM = 329.0'TOP OF ARV = 327.0'+/-TOP OF 12" DIP = 323.0'+/-FM FM FM FM FM FM FM FM FM FM FM FM FM
FM
FM
FM
FM FM FM FM FM FM FM FM FM FM FM FM FM
TCE TCE TCE TCE TCE TCE
TCE
TCE
TCE TCE TCE TCE TCE TCETCETCETCETCE
TCE
TCE
70+00 71+00 72+00 73+00
74+00 75+00 76+00
77+
0
0
32031531030
5
3
0
0
2
9
5
29
0
290
285
28
5
2
8
5
280
295290285275
280280
285300300
325330STA 73+05
20" 22.5° BEND
STA 73+95
20" 22.5° BEND
SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF
SF/
T
P
F
SF/
T
P
F
SF/
T
P
F
TCE TCE TCE TCE TCE TCE
TCE
TCE
TCE TCE TCE TCE TCE
TCETCETCETCETCETCE
TCE
TPF
TPF
TPF
TPF TPF TPF TPF TPF TPF
TPFTPF
TPF
TPF
TPF
TPF
TPF
LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
LOD
LOD
LOD
LOD
LOD
LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
STA 76+67
20" 11.25° BEND
PLOT DATE: 1/19/2021 12:48 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C11 Saved by ENG Save date: 11/12/2020 2:50 PMSNOW HILL ROAD
FORCEMAIN
31453-000
01
JANUARY 2021B. PORTER
IF THIS BAR DOES NOT
MEASURE 1" THEN DRAWING
IS NOT TO FULL SCALE
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT
ENGINEER:
REV ISSUED FOR DATE BY
0 1"1/2"
CONTRACT NO.:
HAZEN NO.:
DATE:
DRAWING
NUMBER:HAZEN AND SAWYER
4011 WESTCHASE BOULEVARD, SUITE 500
RALEIGH, NORTH CAROLINA 27607
LICENSE NO.: C-0381
WHARTON-SMITH, INC.
5601 77 CENTER DRIVE #120, CHARLOTTE,
NORTH CAROLINA 28217
90% SUBMITTAL - NOT FOR CONSTRUCTION
N. JOHNSON
E. NG
C11
20" FORCE MAIN
PLAN AND PROFILE
STATION 70+00 TO 77+00
B. PORTER
PROFILE
H: 1" = 30' V: 1" = 3'MATCHLINE - STA 70+00 SEE SHEET C10MATCHLINE - STA 77+00 SEE SHEET C12SCALE: 1" = 30'
PLAN
20" FORCE MAIN, TYP
25'40'25' TEMPORARY CONSTRUCTION
EASEMENT, TYP
EXISTING 40' EASEMENT, TYP
15'EX 12" FORCE MAIN, TYP
EXISTING GRADE, TYP
20" PC 350 DIP FORCE MAIN, TYP
MIN 3.5' COVER
EXISTING GRADE, TYP
20" PC 350 DIP FORCE MAIN, TYP
STATE OF NORTH CAROLINA
D.B. 5510, PG. 636
P.B. 91, PG. 47
ADDRESS: 5723 WANDERLUST LANE
WAN
D
E
RL
U
S
T L
N
STATE OF NORTH CAROLINA
D.B. 5510, PG. 636
ADDRESS: 5717 WANDERLUST LANE
SCOTTIE DOUGLAS McFARLAND
D.B. 215, PG. 458
P.B. 14, PG. 96
P.B. 5A, PG. 65
ADDRESS: 2132 INFINITY ROAD
SILT FENCE, TYP.
C-31-0400
LIMITS OF DISTURBANCE,
SEE NOTE 1
FIBER FILTRATION TUBE
C-31-0424
TREE PROTECTION
FENCE, TYP.
C-31-0404
130 LF RESTRAINED JOINT
NOTES:
1.LOD LINE IS NOT SHOWN CONTINUOUSLY FOR
CLARITY. THE LIMITS OF DISTURBANCE SHALL BE
COINCIDENT WITH THE PROPOSED EASEMENT LIMITS
AND PROPOSED TEMPORARY EASEMENT LIMITS
WHERE NO LOD IS SHOWN.
SILT FENCESILT F
E
N
C
E
SILT FEN
C
E SOIL PATHSOIL PATHSOIL PATHSOIL PATHSOIL PATH
SOIL
P
A
T
H
12" DIP BYPASS VALVEMANHOLE & GATE VALVEGATE VALVESMANHOLERIM= 279.7'INVERT IN (S)= 261.4'INV OUT (N)= 261.3'MANHOLERIM= 279.8'INVERT IN (NE)= 261.8'INVERT IN (S)= 261.1'INV OUT (W)= 261.1'ARV MANHOLERIM = 272.3'TOP OF 12" DIP = 262.4'+/-MANHOLE FULL OF WATERCANNOT SEE PIPEARV MANHOLERIM = 272.6'TOP OF ARV = 268.6'+/-TOP OF 30" DIP = 266.3'+/-ARV MANHOLERIM = 275.0'TOP OF ARV = 270.4'+/-TOP OF 12" DIP = 268.3'+/-ARV MANHOLE
RIM = 273.2'
TOP OF ARV =
2
6
8
.
6
'
+
/
-
TOP OF 12" DI
P
=
2
6
6
.
0
'
+
/
-
12" PVC
21
"
D
I
P21" DIP21" DIPFM
FM
FM
FM
FM
FM RIP-RAPRIP-RAPENO RIVERENO RIVER
ENO R
IVER
FM
FMFMFMFM
FM
FM
FM
F
M
F
M
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM FM FM
FM
FM
FM
FM FM
FM
FM
FMSILT FENCESILT F
E
N
C
E
SILT FEN
C
E SOIL PATHSOIL PATHSOIL PATHSOIL PATHSOIL PATH
SOIL
P
A
T
H
12" DIP BYPASS VALVEMANHOLE & GATE VALVEGATE VALVESMANHOLERIM= 279.7'INVERT IN (S)= 261.4'INV OUT (N)= 261.3'MANHOLERIM= 279.8'INVERT IN (NE)= 261.8'INVERT IN (S)= 261.1'INV OUT (W)= 261.1'ARV MANHOLERIM = 272.3'TOP OF 12" DIP = 262.4'+/-MANHOLE FULL OF WATERCANNOT SEE PIPEARV MANHOLERIM = 272.6'TOP OF ARV = 268.6'+/-TOP OF 30" DIP = 266.3'+/-ARV MANHOLERIM = 275.0'TOP OF ARV = 270.4'+/-TOP OF 12" DIP = 268.3'+/-ARV MANHOLE
RIM = 273.2'
TOP OF ARV =
2
6
8
.
6
'
+
/
-
TOP OF 12" DI
P
=
2
6
6
.
0
'
+
/
-
12" PVC
21
"
D
I
P21" DIP21" DIPFM
FM
FM
FM
FM
FM RIP-RAPRIP-RAPENO RIVERENO RIVER
ENO R
IVER
FM
FMFMFMFM
FM
FM
FM
F
M
F
M
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM FM FM
FM
FM
FM
FM FM
FM
FM
FMTCE TCETCETCE
TCE
76+00 77+00 78+00 79+00 80+00 81+00 82+00 83+00 84+00 85+00 86+00 87+00 88+00 89+00 90+00 91+00 92+00 93+00 94+00 95+00 96+00 97+00 98+00 99+00 100+00 101+00 102+00 103+00 104+00 105+00 106+00 107+00 108+00 109+00 110+00
111+00
1
1
2
+
0
0
225
230
235
240
245
250
255
260
265
270
275
280
285
290
295
300
305
310
315
320
225
230
235
240
245
250
255
260
265
270
275
280
285
290
295
300
305
310
315
320
76+00 77+00 78+00 79+00 80+00 81+00 82+00 83+00 84+00 85+00 86+00 87+00 88+00 89+00 90+00 91+00 92+00 93+00 94+00 95+00 96+00 97+00 98+00 99+00 100+00 101+00 102+00 103+00 104+00 105+00 106+00 107+00 108+00 109+00 110+00
OVERALL HDD PLAN
1" = 120'
N. JOHNSON
E. NG
C12
HDD OVERALL PLAN & PROFILE
B. PORTER
STA 78+00
HDD EXIT POINT
STA 90+63
START OF HORIZONTAL CURVE
STA 93+27
END OF HORIZONTAL CURVE
HORIZONTAL CURVE
R=1,000'
24" HDPE DR11 FORCEMAIN STA 109+76
HDD ENTRY POINT
ENO R
IVER
ENO RIVERENO R
I
V
ER
PLOT DATE: 1/19/2021 12:49 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C12 Saved by ENG Save date: 11/2/2020 8:18 PMSNOW HILL ROAD
FORCEMAIN
31453-000
01
JANUARY 2021B. PORTER
IF THIS BAR DOES NOT
MEASURE 1" THEN DRAWING
IS NOT TO FULL SCALE
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT
ENGINEER:
REV ISSUED FOR DATE BY
0 1"1/2"
CONTRACT NO.:
HAZEN NO.:
DATE:
DRAWING
NUMBER:HAZEN AND SAWYER
4011 WESTCHASE BOULEVARD, SUITE 500
RALEIGH, NORTH CAROLINA 27607
LICENSE NO.: C-0381
WHARTON-SMITH, INC.
5601 77 CENTER DRIVE #120, CHARLOTTE,
NORTH CAROLINA 28217
90% SUBMITTAL - NOT FOR CONSTRUCTION
OVERALL HDD PROFILE
1" = 120'
19.6'
21.5'
XSILT F
E
N
C
E
FM
FM
FM
FM
FM FM FM
TBM
BENCHTIE SET IN 12" CEDAR
NAVD '88 ELEV: 280.95'XSILT F
E
N
C
E
FM
FM
FM
FM
FM FM FM
TBM
BENCHTIE SET IN 12" CEDAR
NAVD '88 ELEV: 280.95'
TCE TCETCETCETCETCETCE TCE TCETCE TCE
77+00 78+00 79+00 80+00 81+00 82+00 83+00 84+00
2
7
0
295
2
8
5 2802
7
5
290295300260
26
5
285
2903002903002902
8
0
27
0
SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF
SF/TPFSF/TPFSF/TPF SF/TPF SF/TPF
SF/TPFTPF TPF TPF TPF TPFTPFTPF TPF TPF
ARV MANHOLE
RIM = 273.2'
TOP OF ARV = 268.6'+/-
TOP OF 12" DIP = 266.0'+/-FMFM FM FM FM FM FM FM FMFMFMFMFM
FM
ARV MANHOLE
RIM = 273.2'
TOP OF ARV = 268.6'+/-
TOP OF 12" DIP = 266.0'+/-FMFM FM FM FM FM FM FM FMFMFMFMFM
FM
84+00 85+00 86+00 87+00 88+00 89+00 90+00 91+00
2
7
0
27
0
2
5
5
2
5
5
255255270
270265260
265
265
260
260
26
0
2602652
6
02652
7
0
265
260
255
27
0
2602602
7
0 270PLAN
1" = 30'PLOT DATE: 1/19/2021 12:50 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C13 Saved by ENG Save date: 11/9/2020 4:53 PMSNOW HILL ROAD
FORCEMAIN
31453-000
01
JANUARY 2021B. PORTER
IF THIS BAR DOES NOT
MEASURE 1" THEN DRAWING
IS NOT TO FULL SCALE
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT
ENGINEER:
REV ISSUED FOR DATE BY
0 1"1/2"
CONTRACT NO.:
HAZEN NO.:
DATE:
DRAWING
NUMBER:HAZEN AND SAWYER
4011 WESTCHASE BOULEVARD, SUITE 500
RALEIGH, NORTH CAROLINA 27607
LICENSE NO.: C-0381
WHARTON-SMITH, INC.
5601 77 CENTER DRIVE #120, CHARLOTTE,
NORTH CAROLINA 28217
90% SUBMITTAL - NOT FOR CONSTRUCTION
N. JOHNSON
E. NG
C13
20" FORCE MAIN
PLAN
STATION 77+00 TO 91+00
B. PORTERMATCHLINE - STA 77+00 SEE SHEET C12MATCHLINE - STA 84+00 SEE THIS SHEETNOTES:
1.SEE PROFILE ON SHEET C16 AND C17.
EN
O
R
I
V
E
R
MATCHLINE - STA 84+00 SEE THIS SHEETMATCHLINE - STA 91+00 SEE SHEET C14PROPOSED
30' EASEMENT, TYP
EXISTING 40' EASEMENT, TYP
ENO RIVER
PLAN
1" = 30'
PROPOSED 30' EASEMENT, TYP
EX 12" FM, TYP
EX 30" EMPTY PIPE, TYP
STA 78+00
HDD EXIT POINT
ENO R
IVER
STA 90+63
START OF HORIZONTAL CURVE
HORIZONTAL CURVE
R=1000'
SILT FENCE, TYP.
C-31-0400
LIMITS OF DISTUBANCE
TREE PROTECTION
FENCE, TYP.
C-31-0404
24" HDPE DR11 FORCE MAIN, TYP
24" HDPE DR11 FORCE MAIN, TYP
TBM
BENCHTIE SET IN 18" SWEETGUM
NAVD '88 ELEV: 273.55'
FM
FM
FM
FM
FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM
TBM
BENCHTIE SET IN 18" SWEETGUM
NAVD '88 ELEV: 273.55'
FM
FM
FM
FM
FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM91+00
92+00
93+00 94+00 95+00 96+00 97+00 98+00 270270270270
270
TBM
BENCHTIE SET IN 18" PINE
NAVD '88 ELEV: 272.98'
FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
TBM
BENCHTIE SET IN 18" PINE
NAVD '88 ELEV: 272.98'
FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
98+00 99+00 100+00 101+00 102+00 103+00 104+00 105+00
270
270
2
7
0
2
7
0
270270270270PLAN
1" = 30'PLOT DATE: 1/19/2021 12:51 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C14 Saved by AMARCH Save date: 11/9/2020 11:18 AMSNOW HILL ROAD
FORCEMAIN
31453-000
01
JANUARY 2021B. PORTER
IF THIS BAR DOES NOT
MEASURE 1" THEN DRAWING
IS NOT TO FULL SCALE
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT
ENGINEER:
REV ISSUED FOR DATE BY
0 1"1/2"
CONTRACT NO.:
HAZEN NO.:
DATE:
DRAWING
NUMBER:HAZEN AND SAWYER
4011 WESTCHASE BOULEVARD, SUITE 500
RALEIGH, NORTH CAROLINA 27607
LICENSE NO.: C-0381
WHARTON-SMITH, INC.
5601 77 CENTER DRIVE #120, CHARLOTTE,
NORTH CAROLINA 28217
90% SUBMITTAL - NOT FOR CONSTRUCTION
N. JOHNSON
E. NG
C14
20" FORCE MAIN
PLAN
STATION 91+00 TO 105+00
B. PORTERMATCHLINE - STA 91+00 SEE SHEET C13MATCHLINE - STA 98+00 SEE THIS SHEETNOTES:
1.SEE PROFILE ON SHEET C17, C18, AND C19.
24" HDPE DR11 FORCE MAIN, TYP
EXISTING 40' EASEMENT, TYP
MATCHLINE - STA 99+00 SEE THIS SHEETMATCHLINE - STA 105+00 SEE SHEET C15PLAN
1" = 30'
24" HDPE DR11 FORCE MAIN, TYP
PROPOSED 30' EASEMENT
EXISTING 40' EASEMENT, TYP EXISTING 12" FM, TYP
EXISTING 12" FM, TYP
STA 93+27
END OF HORIZONTAL CURVE
HORIZONTAL CURVE
R=1000'
12" DIP BYPASS VALVEMANHOLE & GATE VALVEGATE VALVESMANHOLERIM= 279.8'INVERT IN (NE)= 261.8'INVERT IN (S)= 261.1'INV OUT (W)= 261.1'12" PVC 21" DIPT
B
M
B
E
N
C
H
T
I
E
S
E
T
I
N
1
6
"
P
I
N
E
N
A
V
D
'
8
8
E
L
E
V
:
2
7
2
.
8
7
'
F
M
F
M
F
M
F
M
F
M
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM12" DIP BYPASS VALVEMANHOLE & GATE VALVEGATE VALVESMANHOLERIM= 279.8'INVERT IN (NE)= 261.8'INVERT IN (S)= 261.1'INV OUT (W)= 261.1'12" PVC 21" DIPT
B
M
B
E
N
C
H
T
I
E
S
E
T
I
N
1
6
"
P
I
N
E
N
A
V
D
'
8
8
E
L
E
V
:
2
7
2
.
8
7
'
F
M
F
M
F
M
F
M
F
M
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
TCETCE105+00 106+00 107+00 108+00 109+00 110+
0
0
111+
0
0270270270260
260260265STA 109+73
20" 22.5° BEND
STA 111+01
20" 22.5° BEND
S
F
S
F
S
F
S
F
S
F
/
T
P
FSF/TPFSF/TPFSF/TPFSF/TPFSF/TPFSF/TPF
SF/TPF
TCETCELODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
LOD
LOD
LOD
LODLODL
O
D
L
O
D
L
O
D
L
O
D
L
O
D
L
O
D
L
O
D
L
O
D
L
O
D260265STA 109+58
3" AIR VACUUM VALVE
(FULL SIZED OUTLET)
PLAN
1" = 30'PLOT DATE: 1/19/2021 12:52 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C15 Saved by ENG Save date: 11/17/2020 9:01 AMSNOW HILL ROAD
FORCEMAIN
31453-000
01
JANUARY 2021B. PORTER
IF THIS BAR DOES NOT
MEASURE 1" THEN DRAWING
IS NOT TO FULL SCALE
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT
ENGINEER:
REV ISSUED FOR DATE BY
0 1"1/2"
CONTRACT NO.:
HAZEN NO.:
DATE:
DRAWING
NUMBER:HAZEN AND SAWYER
4011 WESTCHASE BOULEVARD, SUITE 500
RALEIGH, NORTH CAROLINA 27607
LICENSE NO.: C-0381
WHARTON-SMITH, INC.
5601 77 CENTER DRIVE #120, CHARLOTTE,
NORTH CAROLINA 28217
90% SUBMITTAL - NOT FOR CONSTRUCTION
N. JOHNSON
E. NG
C15
20" FORCE MAIN
PLAN AND PROFILE
STATION 105+00 TO 111+00
B. PORTERMATCHLINE - STA 98+00 SEE SHEET C14MATCHLINE - STA 111+00 SEE SHEET C20NOTES:
1.SEE PROFILE ON SHEET C19.
EXISTING 40' EASEMENT, TYP
24" HDPE DR11 FORCE MAIN, TYP
PROPOSED 30' EASEMENT, TYP
EX 12" FM, TYP
EX 30" EMPTY PIPE, TYP
PROPOSED TEMPORARY CONSTRUCTION EASEMENT, TYP
SILT FENCE, TYP.
C-31-0400
LIMITS OF DISTUBANCE
TREE PROTECTION
FENCE, TYP.
C-31-0404
EX 36" FM, TYP
STA 109+76
HDD ENTRY POINT
20" FORCE MAIN, TYP
230
235
240
245
250
230
235
240
245
250
80+50 81+00 82+00 83+00 84+00 85+00 86+00
240
245
250
255
260
265
270
275
280
285
290
295
300
305
310
240
245
250
255
260
265
270
275
280
285
290
295
300
305
310
77+00 78+00 79+00 80+00 80+503" AIR VACUUM VALVE(FULL SIZED OUTLET)STA 77+25265
270
275
280
285
290
295
300
305
310
265
270
275
280
285
290
295
300
305
310
80+50 81+00 82+00 83+00 84+00 85+00 86+00
PROFILE
H: 1" = 40' V: 1" = 4'PLOT DATE: 1/19/2021 12:52 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C16 Saved by ENG Save date: 11/2/2020 9:12 PMSNOW HILL ROAD
FORCEMAIN
31453-000
01
JANUARY 2021B. PORTER
IF THIS BAR DOES NOT
MEASURE 1" THEN DRAWING
IS NOT TO FULL SCALE
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT
ENGINEER:
REV ISSUED FOR DATE BY
0 1"1/2"
CONTRACT NO.:
HAZEN NO.:
DATE:
DRAWING
NUMBER:HAZEN AND SAWYER
4011 WESTCHASE BOULEVARD, SUITE 500
RALEIGH, NORTH CAROLINA 27607
LICENSE NO.: C-0381
WHARTON-SMITH, INC.
5601 77 CENTER DRIVE #120, CHARLOTTE,
NORTH CAROLINA 28217
90% SUBMITTAL - NOT FOR CONSTRUCTION
N. JOHNSON
E. NG
C16
20" FORCE MAIN
PROFILE
STATION 77+00 TO 86+00
B. PORTER
EX GRADE, TYP
MIN 1000' RADIUS, TYP
24" HDPE DR11 FORCEMAIN, TYP
EXIT ANGLE
TBD BY HDD CONTRACTOR
ENO RIVER*253 LF RESTRAINED JOINT
225
230
235
240
245
250
255
260
265
270
275
280
285
225
230
235
240
245
250
255
260
265
270
275
280
285
86+00 87+00 88+00 89+00 90+00 91+00 92+00 93+00 94+00 95+00
PROFILE
H: 1" = 40' V: 1" = 4'PLOT DATE: 1/19/2021 12:53 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C17 Saved by ENG Save date: 11/2/2020 9:05 PMSNOW HILL ROAD
FORCEMAIN
31453-000
01
JANUARY 2021B. PORTER
IF THIS BAR DOES NOT
MEASURE 1" THEN DRAWING
IS NOT TO FULL SCALE
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT
ENGINEER:
REV ISSUED FOR DATE BY
0 1"1/2"
CONTRACT NO.:
HAZEN NO.:
DATE:
DRAWING
NUMBER:HAZEN AND SAWYER
4011 WESTCHASE BOULEVARD, SUITE 500
RALEIGH, NORTH CAROLINA 27607
LICENSE NO.: C-0381
WHARTON-SMITH, INC.
5601 77 CENTER DRIVE #120, CHARLOTTE,
NORTH CAROLINA 28217
90% SUBMITTAL - NOT FOR CONSTRUCTION
N. JOHNSON
E. NG
C17
20" FORCE MAIN
PLAN AND PROFILE
STATION 86+00 TO 95+00
B. PORTER
24" HDPE DR11 FORCEMAIN, TYP
ENO RIVER
EX GRADE, TYP
EX 12" FM
19.6'
225
230
235
240
245
250
255
260
265
270
275
280
285
225
230
235
240
245
250
255
260
265
270
275
280
285
95+00 96+00 97+00 98+00 99+00 100+00 101+00 102+00 103+00 104+00
PROFILE
H: 1" = 40' V: 1" = 4'PLOT DATE: 1/19/2021 12:53 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C18 Saved by ENG Save date: 10/30/2020 8:24 PMSNOW HILL ROAD
FORCEMAIN
31453-000
01
JANUARY 2021B. PORTER
IF THIS BAR DOES NOT
MEASURE 1" THEN DRAWING
IS NOT TO FULL SCALE
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT
ENGINEER:
REV ISSUED FOR DATE BY
0 1"1/2"
CONTRACT NO.:
HAZEN NO.:
DATE:
DRAWING
NUMBER:HAZEN AND SAWYER
4011 WESTCHASE BOULEVARD, SUITE 500
RALEIGH, NORTH CAROLINA 27607
LICENSE NO.: C-0381
WHARTON-SMITH, INC.
5601 77 CENTER DRIVE #120, CHARLOTTE,
NORTH CAROLINA 28217
90% SUBMITTAL - NOT FOR CONSTRUCTION
N. JOHNSON
E. NG
C18
20" FORCE MAIN
PROFILE
STATION 95+00 TO 104+00
B. PORTER
EX GRADE, TYP
24" HDPE DR11 FORCEMAIN, TYP
225
230
235
240
245
250
255
260
265
270
275
280
285
225
230
235
240
245
250
255
260
265
270
275
280
285
104+00 105+00 106+00 107+00 108+00 109+00 110+00 111+0020" 22.5° BENDSTA 109+7320" 22.5° VERT BENDSTA 110+0720" 22.5° VERT BENDSTA 110+1220" 22.5° VERT BENDSTA 110+3820" 22.5° VERT BENDSTA 110+323" AIR VACUUM VALVE(FULL SIZED OUTLET)STA 109+58PROFILE
H: 1" = 40' V: 1" = 4'PLOT DATE: 1/19/2021 12:54 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C19 Saved by ENG Save date: 11/2/2020 9:06 PMSNOW HILL ROAD
FORCEMAIN
31453-000
01
JANUARY 2021B. PORTER
IF THIS BAR DOES NOT
MEASURE 1" THEN DRAWING
IS NOT TO FULL SCALE
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT
ENGINEER:
REV ISSUED FOR DATE BY
0 1"1/2"
CONTRACT NO.:
HAZEN NO.:
DATE:
DRAWING
NUMBER:HAZEN AND SAWYER
4011 WESTCHASE BOULEVARD, SUITE 500
RALEIGH, NORTH CAROLINA 27607
LICENSE NO.: C-0381
WHARTON-SMITH, INC.
5601 77 CENTER DRIVE #120, CHARLOTTE,
NORTH CAROLINA 28217
90% SUBMITTAL - NOT FOR CONSTRUCTION
N. JOHNSON
E. NG
C19
20" FORCE MAIN
PLAN AND PROFILE
STATION 104+00 TO 111+00
B. PORTER
*
EX GRADE, TYP
MIN 1000' RADIUS, TYP
24" HDPE DR11 FORCEMAIN, TYP
ENTRY ANGLE
TBD BY HDD CONTRACTOR
EX 12" FM
EX 36" FM
EX 21" SS
18"
MIN
431 LF RESTRAINED JOINTSTA 109+43TRANSITION FROM24" HDPE TO 20" DIP
255
260
265
270
275
280
255
260
265
270
275
280
111+00 112+00 113+00 114+00 115+00 116+00 117+00 118+0020" 22.5° BENDSTA 111+0120" PLUG VALVESTA 112+00SOIL PATH SOIL PATHMANHOLE
RIM= 279.1'
INVERT IN (E)= 260.6'
INV OUT (W)= 260.6'
ARV MANHOLE
RIM = 276.7'
TOP OF ARV = 272.2'+/-
TOP OF 12" DIP = 269.6'+/-
21" DIP21" DIP
FM FM FM FM FM FM FM FM
FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM
SOIL PATH SOIL PATHMANHOLE
RIM= 279.1'
INVERT IN (E)= 260.6'
INV OUT (W)= 260.6'
ARV MANHOLE
RIM = 276.7'
TOP OF ARV = 272.2'+/-
TOP OF 12" DIP = 269.6'+/-
21" DIP21" DIP
FM FM FM FM FM FM FM FM
FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM
111+
0
0 112+00 113+00 114+00 115+00 116+00 117+00 118+00
2
7
0270
2
7
0
270STA 111+01
20" 22.5° BEND
SF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
STA 112+00
20" PLUG VALVE
PLAN
1" = 30'
PROFILE
H: 1" = 30' V: 1" = 3'PLOT DATE: 1/19/2021 12:55 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C20 Saved by ENG Save date: 11/12/2020 4:03 PMSNOW HILL ROAD
FORCEMAIN
31453-000
01
JANUARY 2021B. PORTER
IF THIS BAR DOES NOT
MEASURE 1" THEN DRAWING
IS NOT TO FULL SCALE
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT
ENGINEER:
REV ISSUED FOR DATE BY
0 1"1/2"
CONTRACT NO.:
HAZEN NO.:
DATE:
DRAWING
NUMBER:HAZEN AND SAWYER
4011 WESTCHASE BOULEVARD, SUITE 500
RALEIGH, NORTH CAROLINA 27607
LICENSE NO.: C-0381
WHARTON-SMITH, INC.
5601 77 CENTER DRIVE #120, CHARLOTTE,
NORTH CAROLINA 28217
90% SUBMITTAL - NOT FOR CONSTRUCTION
N. JOHNSON
E. NG
C20
20" FORCE MAIN
PLAN AND PROFILE
STATION 111+00 TO 118+00
B. PORTERMATCHLINE - STA 111+00 SEE SHEET C15MATCHLINE - STA 118+00 SEE SHEET C21EX 36" FORCE MAIN, TYP
20" FORCE MAIN, TYP
EXISTING GRADE, TYP
20" PC 350 DIP FORCE MAIN, TYP
EX 12" FORCE MAIN, TYP
MIN 3.5' COVER30'25'EXISTING 30' SANITARY SEWER EASEMENT, TYP
EXISTING 25' SANITARY SEWER EASEMENT, TYP
SILT FENCE, TYP.
C-31-0400
LIMITS OF DISTURBANCE, TYP.
FIBER FILTRATION TUBE, TYP.
C-31-0424
TREE PROTECTION
FENCE, TYP.
C-31-0404
431 LF RESTRAINED JOINT
NOTES:
1.AFTER THE NEW 20" FORCE MAIN IS IN SERVICE,
ABANDON EXISTING ARV MH IN PLACE. RETURN ARV
AND VALVES TO THE CITY OF DURHAM.
SEE NOTE 1
20" 45° BENDSTA 122+4120" 11.25° BENDSTA 122+61255
260
265
270
275
280
255
260
265
270
275
280
118+00 119+00 120+00 121+00 122+00 123+00 124+00 125+00
SOIL PATH
MANHOLE
RIM= 279.0'
INVERT IN (E)= 260.1'
INV OUT (W)= 260.1'
21" DIP
FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM
117+00 118+00 119+00 120+00 121+00
270270
SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
GATE
GRAVEL
MANHOLE
RIM= 279.2'
INVERT IN (E)= 259.5'
INV OUT (NW)= 259.4'
21" DIP
TBM
BENCHTIE SET IN 18" PINE
NAVD '88 ELEV: 272.92'FMFMFMFMFMFMFM
FM FM FM FM FM FM FM FM FM FM
121+00122+00123+00 124+00 125+00
STA 122+61
20" 11.25° BEND
STA 122+41
20" 45° BEND
SF/TPFSF/TPFSF/TPFSF/TPFSF/TPFSF/TPFSF/TPFSF SF SF SF SF SF SF SF SF SF SF SF
TPF TPF TPF TPF TPF TPF
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
PLOT DATE: 1/19/2021 12:56 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C21 Saved by ENG Save date: 11/12/2020 4:03 PMSNOW HILL ROAD
FORCEMAIN
31453-000
01
JANUARY 2021B. PORTER
IF THIS BAR DOES NOT
MEASURE 1" THEN DRAWING
IS NOT TO FULL SCALE
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT
ENGINEER:
REV ISSUED FOR DATE BY
0 1"1/2"
CONTRACT NO.:
HAZEN NO.:
DATE:
DRAWING
NUMBER:HAZEN AND SAWYER
4011 WESTCHASE BOULEVARD, SUITE 500
RALEIGH, NORTH CAROLINA 27607
LICENSE NO.: C-0381
WHARTON-SMITH, INC.
5601 77 CENTER DRIVE #120, CHARLOTTE,
NORTH CAROLINA 28217
90% SUBMITTAL - NOT FOR CONSTRUCTION
N. JOHNSON
E. NG
C21
20" FORCE MAIN
PLAN AND PROFILE
STATION 118+00 TO 125+00
----MATCHLINE - STA 121+00 SEE THIS SHEETM
A
T
C
H
L
I
N
E
-
S
T
A
1
2
1
+
0
0
S
E
E
T
H
I
S
S
H
E
E
TMATCHLINE - STA 118+00 SEE SHEET C20MATCHLINE - STA 125+00 SEE SHEET C2230'25'EXISTING 30' SANITARY SEWER EASEMENT, TYP
EXISTING 25' SANITARY SEWER EASEMENT, TYP
PLAN
1" = 30'
EX 36" FORCE MAIN, TYP
20" FORCE MAIN, TYP
EXISTING GRADE, TYP
20" PC 350 DIP FORCE MAIN, TYP
EX 12" FORCE MAIN, TYP
PLAN
1" = 30'
PROFILE
H: 1" = 30' V: 1" = 3'
WETLAND, TYP
MIN 3.5' COVER
SILT FENCE, TYP.
C-31-0400
LIMITS OF DISTURBANCE, TYP.TREE PROTECTION
FENCE, TYP.
C-31-0404
74 LF RESTRAINED JOINT
EX 36" FORCE MAIN, TYP
255
260
265
270
275
280
255
260
265
270
275
280
125+00 126+00 127+00 128+00 129+00 130+00 131+00 132+00
SOIL PATH
INV= 271.1'
INV= 271.1'40" DIPVENT
MANHOLE
RIM= 278.6'
INVERT IN (SE)= 258.6'
INV OUT (NW)= 258.5'
SS MANHOLE
RIM= 278.2'
INVERT IN (SE)= 258.9'
INV OUT (NW)= 258.9'
ARV MANHOLE
RIM = 278.7'
TOP OF ARV = 274.7'+/-
BOTTOM OF MANHOLE = 270.1+/-
CANNOT SEE PIPE
21" DIP
TBM
BENCHTIE SET IN 18" PINE
NAVD '88 ELEV: 276.61'
FM FM FM FM FM FM FM FM
SOIL PATH
INV= 271.1'
INV= 271.1'40" DIPVENT
MANHOLE
RIM= 278.6'
INVERT IN (SE)= 258.6'
INV OUT (NW)= 258.5'
SS MANHOLE
RIM= 278.2'
INVERT IN (SE)= 258.9'
INV OUT (NW)= 258.9'
ARV MANHOLE
RIM = 278.7'
TOP OF ARV = 274.7'+/-
BOTTOM OF MANHOLE = 270.1+/-
CANNOT SEE PIPE
21" DIP
TBM
BENCHTIE SET IN 18" PINE
NAVD '88 ELEV: 276.61'
FM FM FM FM FM FM FM FM
125+00 126+00 127+00 128+00 129+00 130+00 131+00 132+00
SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF
SF SF SF SF SF SF SF
SF SF SF SF SF SF SF
SF
SF
SF
SF SF SF
TPF TPF TPF TPF TPF TPF TPF TPF TPF TPF TPFFFTFFTFFT
FFT FFT FFT FFT
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
PLAN
1" = 30'
PROFILE
H: 1" = 30' V: 1" = 3'PLOT DATE: 1/19/2021 12:56 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C22 Saved by ENG Save date: 11/12/2020 4:16 PMSNOW HILL ROAD
FORCEMAIN
31453-000
01
JANUARY 2021B. PORTER
IF THIS BAR DOES NOT
MEASURE 1" THEN DRAWING
IS NOT TO FULL SCALE
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT
ENGINEER:
REV ISSUED FOR DATE BY
0 1"1/2"
CONTRACT NO.:
HAZEN NO.:
DATE:
DRAWING
NUMBER:HAZEN AND SAWYER
4011 WESTCHASE BOULEVARD, SUITE 500
RALEIGH, NORTH CAROLINA 27607
LICENSE NO.: C-0381
WHARTON-SMITH, INC.
5601 77 CENTER DRIVE #120, CHARLOTTE,
NORTH CAROLINA 28217
90% SUBMITTAL - NOT FOR CONSTRUCTION
N. JOHNSON
E. NG
C22
20" FORCE MAIN
PLAN AND PROFILE
STATION 125+00 TO 132+00
----MATCHLINE - STA 125+00 SEE SHEET C21MATCHLINE - STA 132+00 SEE SHEET C23NOTES:
1.AFTER THE NEW 20" FORCE MAIN IS IN SERVICE,
EXCAVATE TO THE 12" FORCE MAIN CONNECTION AT
THE EXISTING MANHOLE. DISCONNECT THE 12"
FORCE MAIN FROM THE MANHOLE, REPAIR THE
CONNECTION AT THE MANHOLE, AND PLUG 12" PIPE
TO ABANDON THE MAIN.
2.THE LIMITS OF DISTURBANCE SHALL NOT EXCEED 30'
IN WIDTH WHILE WITHIN REGULATORY STREAM
BUFFERS.
EXISTING 30' SANITARY SEWER EASEMENT, TYP
EX 36" FORCE MAIN, TYP
EXISTING 25' SANITARY SEWER EASEMENT, TYP
20" FORCE MAIN, TYP30'25'WETLAND, TYP
EX 12" FORCE MAIN, TYP
EXISTING GRADE, TYP
20" PC 350 DIP FORCE MAIN, TYP
SILT FENCE, TYP.
C-31-0400
LIMITS OF DISTURBANCE, TYP.
STREAM CROSSING BYPASS
TREE PROTECTION
FENCE, TYP.
C-31-0404
SEE NOTE 1
STREAM BUFFER, TYP.
SEE NOTE 2
FIBER FILTRATION
TUBE, TYP.
C-35-0700
C-31-0424
255
260
265
270
275
280
255
260
265
270
275
280
132+00 133+00 134+00 135+00 136+00 137+00 138+00 139+0020" 45° BENDSTA 135+5520" 11.25° BENDSTA 135+75SOIL PATH SOIL PATH
INVERT IN (SE)= 258.6'
INV OUT (NW)= 258.5'
21" DIP
SOIL PATH SOIL PATH
INVERT IN (SE)= 258.6'
INV OUT (NW)= 258.5'
21" DIP
132+00 133+00 134+00 135+00
275
SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF
TPF TPF TPF TPF TPF TPF TPF TPF TPF TPF
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
MANHOLE
RIM = 279.0'
INVERT IN (SE)= 258.3'
INV OUT (W)= 258.2'
21" DIP
MANHOLE
RIM = 279.0'
INVERT IN (SE)= 258.3'
INV OUT (W)= 258.2'
21" DIP135+00136+00 137+00 138+00 139+00
2
8
0 280
275275
2
7
5
STA 135+75
20" 11.25° BEND
STA 135+55
20" 45° BEND
SFSFSFSF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SFSFTPFTPF
TPF TPF TPF TPF TPF TPF TPF TPF TPF TPF TPF TPF
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
PLAN
1" = 30'
PROFILE
H: 1" = 30' V: 1" = 3'PLOT DATE: 1/19/2021 12:57 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C23 Saved by ENG Save date: 11/12/2020 4:12 PMSNOW HILL ROAD
FORCEMAIN
31453-000
01
JANUARY 2021B. PORTER
IF THIS BAR DOES NOT
MEASURE 1" THEN DRAWING
IS NOT TO FULL SCALE
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT
ENGINEER:
REV ISSUED FOR DATE BY
0 1"1/2"
CONTRACT NO.:
HAZEN NO.:
DATE:
DRAWING
NUMBER:HAZEN AND SAWYER
4011 WESTCHASE BOULEVARD, SUITE 500
RALEIGH, NORTH CAROLINA 27607
LICENSE NO.: C-0381
WHARTON-SMITH, INC.
5601 77 CENTER DRIVE #120, CHARLOTTE,
NORTH CAROLINA 28217
90% SUBMITTAL - NOT FOR CONSTRUCTION
N. JOHNSON
E. NG
C23
20" FORCE MAIN
PLAN AND PROFILE
STATION 132+00 TO 139+00
----MATCHLINE - STA 132+00 SEE SHEET C22MATCHLINE - STA 139+00 SEE SHEET C2430'25'EXISTING 30' SANITARY SEWER EASEMENT, TYP
20" FORCE MAIN, TYP
EXISTING GRADE, TYP
20" PC DIP FORCE MAIN, TYP 20'30'EXISTING 30' SANITARY SEWER EASEMENT, TYP
MATCHLINE - STA 135+00 SEE THIS SHEETMATCHLINE - STA 135+00 SEE THIS SHEETPLAN
1" = 30'
EXISTING 50' DURHAM WATERLINE &
DUKE POWER EASEMENT, TYP
20' PERMANENT EASEMENT, TYP
25' PERMANENT EASEMENT, TYP
MIN 3.5' COVER
SILT FENCE, TYP.
C-31-0400
LIMITS OF DISTURBANCE, TYP.
TREE PROTECTION
FENCE, TYP.
C-31-0404
74 LF RESTRAINED JOINT
X X
X X X
XX
X
X
X
X
X
6' CH
AI
N
LI
N
K
W/
B
A
R
B
E
D
WI
R
E GATEGATE
6' CHAIN LINK
6'
CHA
IN
L
INKW/
BARBED
W
IRE
GATE
SOIL PATH
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE OHE
GRAV
E
L
GRAVEL
GRAVELGRAVEL
GRAVEL
METAL TANK
METAL TANK
INV= 276.7'
INV= 275.9'
12" CMP
INV= 276.6'
INV= 276.1'15" CMP
EXISTING STORM MANHOLE
RIM = 278.9'
INV IN (N/W) = 275.6'
INV OUT (N/E) = 275.6'EXISTING STORM
MANHOLE RIM = 278.9'
INV IN (N/W) = 275.4'
INV OUT (N/E) = 275.6'
GATE VALVE
MANHOLE
RIM = 280.5'
INV IN (N) = 275.2' (6" DIP)
INV IN (S) = 276.2' (4" DIP)
INV IN (E) = 257.2' (21" DIP)
INV OUT (N)= 257.2' (21" DIP)
MANHOLE
RIM = 280.2'
INVERT IN (E)= 257.8'
INV OUT (W)= 257.7'
21" DIP
TBM
BENCHTIE SET IN 16" MAPLE
NAVD '88 ELEV: 278.78'
ASP
H
A
L
T
GRA
V
E
L
MANHOLE
RIM = 281.3'
INVERT IN (S)= 257.2'
INV OUT (N)= 257.2'
PIPES ARE NOT VISIBLE IN MANHOLE
EXISTING STORM MANHOLE
NO RIM - OPEN HOLE
TOP OF STRUCTURE AT GROUND = 277.8'
INV IN (N/W) = 276.2'
INV IN (N/E) = 276.1'
INV OUT (S/E) = 275.9'
GRA
V
E
L
PLUG VALVE
18" DIP - BYPASS VALVES
4" PVC
APPROX DIRECTION
METAL TANK
145+58139+00 140+00 141+00 142+00 143+00 144+00
145+00280
280 280 280
280
280
28
0
2
8
0
280
275
275
275
MH-03
RIM: 279.08
INV IN: 257.23
INV OUT: 257.23
STA 143+21
20" 11.25° BEND
STA 143+69
20" 11.25° BEND
MH-02
RIM: 278.49
INV IN: 257.65
INV IN: 257.22
INV OUT: 257.45
MH-01
RIM: 277.13
INV IN: 266.72
INV OUT: 257.66
MH-04
RIM: 279.33
INV IN: 257.20
INV OUT: 257.20
SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF SF/TPF
SFSFSF SF SF SF SF SF SF SF SF
TPF TPF TPF TPF TPF TPF TPF TPF
LOD
LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
LOD
STA 143+00
3" AIR VACUUM VALVE
(FULL SIZED OUTLET)
255
260
265
270
275
280
285
255
260
265
270
275
280
285
139+00 140+00 141+00 142+00 143+00 144+00 145+00 146+00 147+00
38 LF 48" DIP @ 0.08%58 LF 48" DIP @ 0.38%20" 11.25° BENDSTA 143+2124 LF 48" DIP @ 0.04%3" AIR VACUUM VALVE(FULL SIZED OUTLET)STA 143+0020" 11.25° BENDSTA 143+69MH-03INV IN: 257.23 (48" DIP)INV OUT: 257.23 (48" DIP)STA 145+04RIM: 279.08MH-02INV IN: 257.65 (48" DIP)INV IN: 257.22 (21" DIP)INV OUT: 257.45 (48" DIP)STA 144+47RIM: 278.49MH-01INV IN: 257.86 (20" DIP)INV OUT: 257.66 (48" DIP)STA 144+23RIM: 277.13MH-04INV IN: 257.20 (48" DIP)INV OUT: 257.20 (48" DIP)STA 145+42RIM: 279.33PLOT DATE: 1/19/2021 12:58 PM BY: AMARCHFile: O:\31453-RAL\31453-000\CAD_BIM\FORCEMAIN\CIVIL\C24 Saved by ENG Save date: 11/12/2020 4:16 PMSNOW HILL ROAD
FORCEMAIN
31453-000
01
JANUARY 2021B. PORTER
IF THIS BAR DOES NOT
MEASURE 1" THEN DRAWING
IS NOT TO FULL SCALE
CHECKED BY:
DRAWN BY:
DESIGNED BY:
PROJECT
ENGINEER:
REV ISSUED FOR DATE BY
0 1"1/2"
CONTRACT NO.:
HAZEN NO.:
DATE:
DRAWING
NUMBER:HAZEN AND SAWYER
4011 WESTCHASE BOULEVARD, SUITE 500
RALEIGH, NORTH CAROLINA 27607
LICENSE NO.: C-0381
WHARTON-SMITH, INC.
5601 77 CENTER DRIVE #120, CHARLOTTE,
NORTH CAROLINA 28217
90% SUBMITTAL - NOT FOR CONSTRUCTION
N. JOHNSON
E. NG
C24
20" FORCE MAIN
PLAN AND PROFILE
STATION 139+00 TO 146+00
----
PLAN
1" = 30'
PROFILE
H: 1" = 30' V: 1" = 3'MATCHLINE - STA 139+00 SEE SHEET C23NOTES:
1.ABANDON EXISTING MANHOLE IN PLACE.
2.EXISTING 36" FORCE MAIN BYPASS PIPE IS AROUND
THE EXISTING CONCRETE STRUCTURE, INCLUDING
36" PLUG VALVES. CONTRACTOR SHALL POT HOLE
AND LOCATE EXISTING BYPASS PIPING PRIOR TO
BEGINNING RELOCATION AND REPLACEMENT OF THE
GRAVITY SEWER.
3.LOCATE SOURCE OF 6" DIP AND REDIRECT TO MH-03.
OUTSIDE DROP CONNECTION IS REQUIRED.
EXISTING GRADE, TYP
20" PC 350 DIP FORCE MAIN, TYP
EXISTING 30' SANITARY SEWER EASEMENT, TYP
20' PERMANENT EASEMENT, TYP
36" FORCE MAIN, TYP20'SEE NOTE 1
SILT FENCE, TYP.
C-31-0400
LIMITS OF DISTURBANCE, TYP.
TREE PROTECTION
FENCE, TYP.
C-31-0404
36" BYPASS VALVE
SEE NOTE 2
SEE NOTE 3
209 LF RESTRAINED JOINT
Eno RiverPump Station
Snow Hill RoadPump Station
Figure 3: Impacts Index MapSnow Hill Road Force MainDurham CountyDurham, North Carolina®1 inch = 1,500 feet
0 1,5005001,000 Feet
Legend
Index to Im pacts
Force Main Alignm ent
Limits of Disturbance
Stream
Wetlan ds
Pond
Snow Hill RoadI n f i n i t y R o a d
E n o R i v e r
Cabin Branch
Little RiverFigu res 3A and 4A
Figu res 3B and 4B
Figu res 3C an d 4 C
Figu res 3D an d 4 D
Figure 3A: Waters of the US Impacts MapSnow Hill Road Force MainDurham CountyDurham, North Carolina®1 inch = 100 feet
0 10050Feet
Legend
Force Main Alignment
Limits of Disturbance
Stream
Wetlands
Snow Hill RoadCabin Branch
UT1 to Cabin BranchUT2
t
o Cabi
n Br
anchS1 - Cabin BranchOpen Cut Installation30 Feet of Temporary Impact
S2 - UT1 to Cabin BranchOpen Cut Installation98 Feet of Temporary Impact
S3 - UT2 to Cabin BranchOpen Cut Installation51 Feet of Temporary Impact
Figure 3B: Waters of the US Impacts MapSnow Hill Road Force MainDurham CountyDurham, North Carolina®1 inch = 100 feet
0 10050Feet
Legend
Force Main Alignment
Limits of Disturbance
Stream
Wetlands
Pond
Sno
w Hill Ro
adUT1 to Little River
S4 - UT1 to Little RiverOpen Cut Installation30 Feet of Temporary Impact
Figure 3C: Waters of the US Impacts MapSnow Hill Road Force MainDurham CountyDurham, North Carolina®1 inch = 100 feet
0 10050Feet
Legend
Force Main Alignment
Limits of Disturbance
Stream
Wetlands
S
n
o
w
H
ill
R
o
a
d
UT2 to Little River
S5 - UT2 to Little RiverOpen Cut Installation37 Feet of Temporary Impact
Figure 3D: Waters of the US Impacts MapSnow Hill Road Force MainDurham CountyDurham, North Carolina®1 inch = 100 feet
0 10050Feet
Legend
Force Main Alignment
Limits of Disturbance
Stream
Wetlands
U T 2 to E n o R iv e rS6 - UT2 to Eno RiverOpen Cut Installation30 Feet of Temporary Impact
Eno RiverPump Station
Snow Hill RoadPump Station
Figure 3: Impacts Index MapSnow Hill Road Force MainDurham CountyDurham, North Carolina®1 inch = 1,500 feet
0 1,5005001,000 Feet
Legend
Index to Im pacts
Force Main Alignm ent
Limits of Disturbance
Stream
Wetlan ds
Pond
Snow Hill RoadI n f i n i t y R o a d
E n o R i v e r
Cabin Branch
Little RiverFigu res 3A and 4A
Figu res 3B and 4B
Figu res 3C an d 4 C
Figu res 3D an d 4 D
Figure 4A: Buffer Impacts MapSnow Hill Road Force MainDurham CountyDurham, North Carolina®1 inch = 100 feet
0 10050Feet
Legend
Force Main Alignment
Limits of Disturbance
Permanent Buffer Impact
Temporary Buffer Impact
Stream
Wetlands
Zone 1 Buffer
Zone 2 Buffer
Snow Hill RoadCabin Branch
UT1 to Cabin BranchUT2
t
o Cabi
n Br
anchB1 - Cabin Branch - Deemed Allow ablePerpendicular Crossing for N ew Se wer Installa tionPermanent Impact2,787 Square Feet of Zone 1759 Square Feet of Zone 2
B2 - UT1 to Cabin Branch Allowable with MitigationOther than Perpendicular Crossing for New Sewer InstallationPermanent Impact4,823 Square Feet of Zone 1
B4 - UT1 to Cabin Branch Deemed AllowableOther than Perpendicular Crossing for New Sewer InstallationTemporary Impact1,174 Square Feet of Zone 2
B6 - UT2 to Cabin Branch Deemed AllowableOther than Perpendicular Crossing for New Sewer InstallationPermanent Impact852 Square Feet of Zone 2
B7 - UT2 to Cabin Branch Deemed AllowableOther than Perpendicular Crossing for New Sewer InstallationTemporary Impact483 Square Feet of Zone 2
B3 - UT1 to Cabin Branch Allowable with MitigationOther than Perpendicular Crossing for New Sewer InstallationTemporary Impact2,153 Square Feet of Zone 1
B5 - UT1 to Cabin Branch Deemed AllowableOther than Perpendicular Crossing for New Sewer InstallationPermanent Impact581 Square Feet of Zone 2
B8 - UT2 to Cabin Branch Allowable with MitigationOther than Perpendicular Crossing for New Sewer InstallationPermanent Impact380 Square Feet of Zone 1
B9 - UT2 to Cabin Branch Allowable with MitigationOther than Perpendicular Crossing for New Sewer InstallationTemporary Impact2,508 Square Feet of Zone 1
B7 - UT2 to Cabin Branch Deemed AllowableOther than Perpendicular Crossing for New Sewer InstallationTemporary Impact483 Square Feet of Zone 2
Figure 4B: Buffer Impacts MapSnow Hill Road Force MainDurham CountyDurham, North Carolina®1 inch = 100 feet
0 10050Feet
Legend
Permanent Buffer Impact
Temporary Buffer Impact
Force Main Alignment
Limits of Disturbance
Stream
Wetlands
Pond
Zone 1 Buffer
Zone 2 Buffer
Sno
w Hill Ro
adUT1 to Little River
B11 - UT1 to Little River - Deemed AllowablePerpendicular Crossing for New Sewer InstallationTemporary Impact523 Square Feet of Zone 1498 Square Feet of Zone 2
B10 - UT1 to Little River - Deeme d AllowablePerpendicular Crossing for New Se wer Installa tionPermanent Impact1,893 Square Feet of Zone 11,511 Square Feet of Zone 2
Figure 4C: Buffer Impacts MapSnow Hill Road Force MainDurham CountyDurham, North Carolina®1 inch = 100 feet
0 10050Feet
Legend
Force Main Alignment
Permanent Buffer Impact
Temporary Buffer Impact
Limits of Disturbance
Stream
Zone 1 Buffer
Zone 2 Buffer
S
n
o
w
H
ill
R
o
a
d
UT2 to Little River
B12 - UT2 to Little River - Deeme d AllowablePerpendicular Crossing for New Se wer Installa tionTemporary Impact815 Square Feet of Zone 2
B13 - UT2 to Little River - Deemed AllowablePerpendicular Crossing for New Sewer InstallationPermanent Impact2,278 Square Feet of Zone 1860 Square Feet of Zone 2
Figure 4D: Buffer Impacts MapSnow Hill Road Force MainDurham CountyDurham, North Carolina®1 inch = 100 feet
0 10050Feet
Legend
Force Main Alignment
Permanent Buffer Impact
Temporary Buffer Impact
Limits of Disturbance
Stream
Wetlands
Zone 1 Buffer
Zone 2 Buffer
U T 2 to E n o R iv e rB14 - UT2 to Eno River - Deemed AllowablePerpendicular Crossing for New Sewer InstallationTemporary Impact1,825 Square Feet of Zone 11,216 Square Feet of Zone 2
Snow Hill Road Force Main – diffuse flow discussion
Diffuse flow will be maintained throughout the limits of disturbance and the riparian buffer through the
use of permanent seeding and planting of native and riparian vegetation, and maintenance of existing
drainage patterns throughout the buffered areas. No grading or permanent stormwater measures will
be put in place to channelize or concentrate stormwater runoff from the site. The erosion and sediment
control measures for the project were designed to meet NC DEQ requirements, including the NC Erosion
and Sedimentation Control Planning and Design Manual and the NC Construction General Permit
NCG01, as well as Title 15A, Chapter 4 of the NC Administrative Code. The proposed project will not
create concentrated stormwater flow through the buffer.
Description of Blasting
Blasting is necessary to fracture the subsurface rock so that it can be excavated by mechanical means
when the pipe laying construction equipment digs the pipe trench. It is confined to the pipe alignment,
and blasts are sized and spaced to provide the necessary fracturing while maintaining the fracturing
within the work area limits. Generally, a drill rig works ahead of the trench excavation equipment (pipe
laying crew), and drills pilot holes until the surface of the rock is located. Then, the rig will drill holes to
the depth required through the rock to set the dynamite in the proper location. Typically, the pilot hole
drilling is completed for a certain length ahead of the pipe laying crew to map out the rock profile. The
drilling and blasting crew returns to drill and set the dynamite. The pre-blast effort can take days or
weeks depending on how far ahead of the pipe laying the contractor wants to drill before blasting.
Blasting is typically performedin an isolated section where blast mats can be laid on top of the ground
surface above the blasting area. Setup for blasting may take several days, and a series of blasts in one
location will be performed in one day. The blast locations are dictated by the actual subsurface
conditions discovered during pre-drilling of the pipe alignment.
IPaC resource list
This report is an automatically generated list of species and other resources such as critical habitat
(collectively referred to as trust resources) under the U.S. Fish and Wildlife Service's (USFWS)
jurisdiction that are known or expected to be on or near the project area referenced below. The list
may also include trust resources that occur outside of the project area, but that could potentially be
directly or indirectly affected by activities in the project area. However, determining the likelihood and
extent of effects a project may have on trust resources typically requires gathering additional site-
specific (e.g., vegetation/species surveys) and project-specific (e.g., magnitude and timing of proposed
activities) information.
Below is a summary of the project information you provided and contact information for the USFWS
office(s) with jurisdiction in the defined project area. Please read the introduction to each section that
follows (Endangered Species, Migratory Birds, USFWS Facilities, and NWI Wetlands) for additional
information applicable to the trust resources addressed in that section.
Location
Durham County, North Carolina
Local office
Raleigh Ecological Services Field Office
(919) 856-4520
(919) 856-4556
MAILING ADDRESS
Post Office Box 33726
Raleigh, NC 27636-3726
PHYSICAL ADDRESS
551 Pylon Drive, Suite F
U.S. Fish & Wildlife ServiceIPaCInformation for Planning and Consultation
Page 1 of 11IPaC: Explore Location resources
1/19/2021https://ecos.fws.gov/ipac/location/3TCSQCBFF5BFRHPXGLUBLEUIAU/resources
Raleigh, NC 27606-1487
Page 2 of 11IPaC: Explore Location resources
1/19/2021https://ecos.fws.gov/ipac/location/3TCSQCBFF5BFRHPXGLUBLEUIAU/resources
Endangered species
This resource list is for informational purposes only and does not constitute an analysis of project
level impacts.
The primary information used to generate this list is the known or expected range of each species.
Additional areas of influence (AOI) for species are also considered. An AOI includes areas outside of the
species range if the species could be indirectly affected by activities in that area (e.g., placing a dam
upstream of a fish population even if that fish does not occur at the dam site, may indirectly impact the
species by reducing or eliminating water flow downstream). Because species can move, and site
conditions can change, the species on this list are not guaranteed to be found on or near the project
area. To fully determine any potential effects to species, additional site-specific and project-specific
information is often required.
Section 7 of the Endangered Species Act requires Federal agencies to "request of the Secretary
information whether any species which is listed or proposed to be listed may be present in the area of
such proposed action" for any project that is conducted, permitted, funded, or licensed by any Federal
agency. A letter from the local office and a species list which fulfills this requirement can only be
obtained by requesting an official species list from either the Regulatory Review section in IPaC (see
directions below) or from the local field office directly.
For project evaluations that require USFWS concurrence/review, please return to the IPaC website and
request an official species list by doing the following:
1. Draw the project location and click CONTINUE.
2. Click DEFINE PROJECT.
3. Log in (if directed to do so).
4. Provide a name and description for your project.
5. Click REQUEST SPECIES LIST.
Listed species
and their critical habitats are managed by the Ecological Services Program of the U.S. Fish and Wildlife
Service (USFWS) and the fisheries division of the National Oceanic and Atmospheric Administration
(NOAA Fisheries ).
Species and critical habitats under the sole responsibility of NOAA Fisheries are not shown on this list.
Please contact NOAA Fisheries for species under their jurisdiction.
1. Species listed under the Endangered Species Act are threatened or endangered; IPaC also shows
species that are candidates, or proposed, for listing. See the listing status page for more
information. IPaC only shows species that are regulated by USFWS (see FAQ).
2.NOAA Fisheries, also known as the National Marine Fisheries Service (NMFS), is an office of the
National Oceanic and Atmospheric Administration within the Department of Commerce.
The following species are potentially affected by activities in this location:
1
2
Page 3 of 11IPaC: Explore Location resources
1/19/2021https://ecos.fws.gov/ipac/location/3TCSQCBFF5BFRHPXGLUBLEUIAU/resources
Amphibians
Fishes
Clams
Flowering Plants
NAME STATUS
Neuse River Waterdog Necturus lewisi
Wherever found
There is proposed critical habitat for this species. Your location
overlaps the critical habitat.
https://ecos.fws.gov/ecp/species/6772
Proposed Threatened
NAME STATUS
Carolina Madtom Noturus furiosus
Wherever found
There is proposed critical habitat for this species. Your location
overlaps the critical habitat.
https://ecos.fws.gov/ecp/species/528
Proposed Endangered
NAME STATUS
Atlantic Pigtoe Fusconaia masoni
Wherever found
There is proposed critical habitat for this species. The location of the
critical habitat is not available.
https://ecos.fws.gov/ecp/species/5164
Proposed Threatened
Dwarf Wedgemussel Alasmidonta heterodon
Wherever found
No critical habitat has been designated for this species.
https://ecos.fws.gov/ecp/species/784
Endangered
NAME STATUS
Michaux's Sumac Rhus michauxii
Wherever found
No critical habitat has been designated for this species.
https://ecos.fws.gov/ecp/species/5217
Endangered
Smooth Coneflower Echinacea laevigata
Wherever found
No critical habitat has been designated for this species.
https://ecos.fws.gov/ecp/species/3473
Endangered
Page 4 of 11IPaC: Explore Location resources
1/19/2021https://ecos.fws.gov/ipac/location/3TCSQCBFF5BFRHPXGLUBLEUIAU/resources
Critical habitats
Potential effects to critical habitat(s) in this location must be analyzed along with the endangered
species themselves.
This location overlaps the critical habitat for the following species:
Migratory birds
The birds listed below are birds of particular concern either because they occur on the USFWS Birds of
Conservation Concern (BCC) list or warrant special attention in your project location. To learn more
about the levels of concern for birds on your list and how this list is generated, see the FAQ below. This
is not a list of every bird you may find in this location, nor a guarantee that every bird on this list will be
found in your project area. To see exact locations of where birders and the general public have sighted
birds in and around your project area, visit the E-bird data mapping tool (Tip: enter your location,
desired date range and a species on your list). For projects that occur off the Atlantic Coast, additional
maps and models detailing the relative occurrence and abundance of bird species on your list are
NAME TYPE
Carolina Madtom Noturus furiosus
https://ecos.fws.gov/ecp/species/528#crithab
Proposed
Neuse River Waterdog Necturus lewisi
https://ecos.fws.gov/ecp/species/6772#crithab
Proposed
Certain birds are protected under the Migratory Bird Treaty Act
and the Bald and Golden Eagle Protection Act .
Any person or organization who plans or conducts activities that may result in impacts to migratory
birds, eagles, and their habitats should follow appropriate regulations and consider implementing
appropriate conservation measures, as described below.
1. The Migratory Birds Treaty Act of 1918.
2. The Bald and Golden Eagle Protection Act of 1940.
Additional information can be found using the following links:
• Birds of Conservation Concern http://www.fws.gov/birds/management/managed-species/
birds-of-conservation-concern.php
• Measures for avoiding and minimizing impacts to birds
http://www.fws.gov/birds/management/project-assessment-tools-and-guidance/
conservation-measures.php
• Nationwide conservation measures for birds
http://www.fws.gov/migratorybirds/pdf/management/nationwidestandardconservationmeasures.pdf
1 2
Page 5 of 11IPaC: Explore Location resources
1/19/2021https://ecos.fws.gov/ipac/location/3TCSQCBFF5BFRHPXGLUBLEUIAU/resources
available. Links to additional information about Atlantic Coast birds, and other important information
about your migratory bird list, including how to properly interpret and use your migratory bird report,
can be found below.
For guidance on when to schedule activities or implement avoidance and minimization measures to
reduce impacts to migratory birds on your list, click on the PROBABILITY OF PRESENCE SUMMARY at
the top of your list to see when these birds are most likely to be present and breeding in your project
area.
NAME BREEDING SEASON (IF A BREEDING
SEASON IS INDICATED FOR A BIRD
ON YOUR LIST, THE BIRD MAY
BREED IN YOUR PROJECT AREA
SOMETIME WITHIN THE
TIMEFRAME SPECIFIED, WHICH IS A
VERY LIBERAL ESTIMATE OF THE
DATES INSIDE WHICH THE BIRD
BREEDS ACROSS ITS ENTIRE
RANGE. "BREEDS ELSEWHERE"
INDICATES THAT THE BIRD DOES
NOT LIKELY BREED IN YOUR
PROJECT AREA.)
Bald Eagle Haliaeetus leucocephalus
This is not a Bird of Conservation Concern (BCC) in this area, but
warrants attention because of the Eagle Act or for potential
susceptibilities in offshore areas from certain types of development or
activities.
https://ecos.fws.gov/ecp/species/1626
Breeds Sep 1 to Jul 31
Blue-winged Warbler Vermivora pinus
This is a Bird of Conservation Concern (BCC) only in particular Bird
Conservation Regions (BCRs) in the continental USA
Breeds May 1 to Jun 30
Prairie Warbler Dendroica discolor
This is a Bird of Conservation Concern (BCC) throughout its range in the
continental USA and Alaska.
Breeds May 1 to Jul 31
Prothonotary Warbler Protonotaria citrea
This is a Bird of Conservation Concern (BCC) throughout its range in the
continental USA and Alaska.
Breeds Apr 1 to Jul 31
Red-headed Woodpecker Melanerpes erythrocephalus
This is a Bird of Conservation Concern (BCC) throughout its range in the
continental USA and Alaska.
Breeds May 10 to Sep 10
Page 6 of 11IPaC: Explore Location resources
1/19/2021https://ecos.fws.gov/ipac/location/3TCSQCBFF5BFRHPXGLUBLEUIAU/resources
Probability of Presence Summary
The graphs below provide our best understanding of when birds of concern are most likely to be
present in your project area. This information can be used to tailor and schedule your project activities
to avoid or minimize impacts to birds. Please make sure you read and understand the FAQ "Proper
Interpretation and Use of Your Migratory Bird Report" before using or attempting to interpret this
report.
Probability of Presence ( )
Each green bar represents the bird's relative probability of presence in the 10km grid cell(s) your
project overlaps during a particular week of the year. (A year is represented as 12 4-week months.) A
taller bar indicates a higher probability of species presence. The survey effort (see below) can be used
to establish a level of confidence in the presence score. One can have higher confidence in the
presence score if the corresponding survey effort is also high.
How is the probability of presence score calculated? The calculation is done in three steps:
1. The probability of presence for each week is calculated as the number of survey events in the week
where the species was detected divided by the total number of survey events for that week. For
example, if in week 12 there were 20 survey events and the Spotted Towhee was found in 5 of
them, the probability of presence of the Spotted Towhee in week 12 is 0.25.
2. To properly present the pattern of presence across the year, the relative probability of presence is
calculated. This is the probability of presence divided by the maximum probability of presence
across all weeks. For example, imagine the probability of presence in week 20 for the Spotted
Towhee is 0.05, and that the probability of presence at week 12 (0.25) is the maximum of any week
of the year. The relative probability of presence on week 12 is 0.25/0.25 = 1; at week 20 it is
0.05/0.25 = 0.2.
3. The relative probability of presence calculated in the previous step undergoes a statistical
conversion so that all possible values fall between 0 and 10, inclusive. This is the probability of
presence score.
To see a bar's probability of presence score, simply hover your mouse cursor over the bar.
Breeding Season ( )
Yellow bars denote a very liberal estimate of the time-frame inside which the bird breeds across its
entire range. If there are no yellow bars shown for a bird, it does not breed in your project area.
Survey Effort ( )
Rusty Blackbird Euphagus carolinus
This is a Bird of Conservation Concern (BCC) throughout its range in the
continental USA and Alaska.
Breeds elsewhere
Wood Thrush Hylocichla mustelina
This is a Bird of Conservation Concern (BCC) throughout its range in the
continental USA and Alaska.
Breeds May 10 to Aug 31
Page 7 of 11IPaC: Explore Location resources
1/19/2021https://ecos.fws.gov/ipac/location/3TCSQCBFF5BFRHPXGLUBLEUIAU/resources
Vertical black lines superimposed on probability of presence bars indicate the number of surveys
performed for that species in the 10km grid cell(s) your project area overlaps. The number of surveys is
expressed as a range, for example, 33 to 64 surveys.
To see a bar's survey effort range, simply hover your mouse cursor over the bar.
No Data ( )
A week is marked as having no data if there were no survey events for that week.
Survey Timeframe
Surveys from only the last 10 years are used in order to ensure delivery of currently relevant
information. The exception to this is areas off the Atlantic coast, where bird returns are based on all
years of available data, since data in these areas is currently much more sparse.
Tell me more about conservation measures I can implement to avoid or minimize impacts to migratory birds.
Nationwide Conservation Measures describes measures that can help avoid and minimize impacts to all birds at any
location year round. Implementation of these measures is particularly important when birds are most likely to occur in
the project area. When birds may be breeding in the area, identifying the locations of any active nests and avoiding
their destruction is a very helpful impact minimization measure. To see when birds are most likely to occur and be
breeding in your project area, view the Probability of Presence Summary.Additional measures or permits may be
advisable depending on the type of activity you are conducting and the type of infrastructure or bird species present
on your project site.
What does IPaC use to generate the migratory birds potentially occurring in my specified location?
The Migratory Bird Resource List is comprised of USFWS Birds of Conservation Concern (BCC)and other species that
may warrant special attention in your project location.
The migratory bird list generated for your project is derived from data provided by the Avian Knowledge Network
(AKN). The AKN data is based on a growing collection of survey, banding, and citizen science datasets and is queried
and filtered to return a list of those birds reported as occurring in the 10km grid cell(s) which your project intersects,
and that have been identified as warranting special attention because they are a BCC species in that area, an eagle
(Eagle Act requirements may apply), or a species that has a particular vulnerability to offshore activities or
development.
Again, the Migratory Bird Resource list includes only a subset of birds that may occur in your project area. It is not
representative of all birds that may occur in your project area. To get a list of all birds potentially present in your
project area, please visit the AKN Phenology Tool.
What does IPaC use to generate the probability of presence graphs for the migratory birds potentially occurring in
my specified location?
The probability of presence graphs associated with your migratory bird list are based on data provided by the Avian
Knowledge Network (AKN). This data is derived from a growing collection of survey, banding, and citizen science
datasets .
Probability of presence data is continuously being updated as new and better information becomes available. To learn
more about how the probability of presence graphs are produced and how to interpret them, go the Probability of
Presence Summary and then click on the "Tell me about these graphs" link.
How do I know if a bird is breeding, wintering, migrating or present year-round in my project area?
Page 8 of 11IPaC: Explore Location resources
1/19/2021https://ecos.fws.gov/ipac/location/3TCSQCBFF5BFRHPXGLUBLEUIAU/resources
To see what part of a particular bird's range your project area falls within (i.e. breeding, wintering, migrating or year-
round), you may refer to the following resources:The Cornell Lab of Ornithology All About Birds Bird Guide, or (if you
are unsuccessful in locating the bird of interest there), the Cornell Lab of Ornithology Neotropical Birds guide. If a bird
on your migratory bird species list has a breeding season associated with it, if that bird does occur in your project area,
there may be nests present at some point within the timeframe specified. If "Breeds elsewhere" is indicated, then the
bird likely does not breed in your project area.
What are the levels of concern for migratory birds?
Migratory birds delivered through IPaC fall into the following distinct categories of concern:
1. "BCC Rangewide" birds are Birds of Conservation Concern (BCC) that are of concern throughout their range
anywhere within the USA (including Hawaii, the Pacific Islands, Puerto Rico, and the Virgin Islands);
2. "BCC - BCR" birds are BCCs that are of concern only in particular Bird Conservation Regions (BCRs) in the
continental USA; and
3. "Non-BCC - Vulnerable" birds are not BCC species in your project area, but appear on your list either because of
the Eagle Act requirements (for eagles) or (for non-eagles) potential susceptibilities in offshore areas from certain
types of development or activities (e.g. offshore energy development or longline fishing).
Although it is important to try to avoid and minimize impacts to all birds, efforts should be made, in particular, to avoid
and minimize impacts to the birds on this list, especially eagles and BCC species of rangewide concern. For more
information on conservation measures you can implement to help avoid and minimize migratory bird impacts and
requirements for eagles, please see the FAQs for these topics.
Details about birds that are potentially affected by offshore projects
For additional details about the relative occurrence and abundance of both individual bird species and groups of bird
species within your project area off the Atlantic Coast, please visit the Northeast Ocean Data Portal. The Portal also
offers data and information about other taxa besides birds that may be helpful to you in your project review.
Alternately, you may download the bird model results files underlying the portal maps through the NOAA NCCOS
Integrative Statistical Modeling and Predictive Mapping of Marine Bird Distributions and Abundance on the Atlantic
Outer Continental Shelf project webpage.
Bird tracking data can also provide additional details about occurrence and habitat use throughout the year, including
migration. Models relying on survey data may not include this information. For additional information on marine bird
tracking data, see the Diving Bird Study and the nanotag studies or contact Caleb Spiegel or Pam Loring.
What if I have eagles on my list?
If your project has the potential to disturb or kill eagles, you may need to obtain a permit to avoid violating the Eagle
Act should such impacts occur.
Proper Interpretation and Use of Your Migratory Bird Report
The migratory bird list generated is not a list of all birds in your project area, only a subset of birds of priority concern.
To learn more about how your list is generated, and see options for identifying what other birds may be in your project
area, please see the FAQ "What does IPaC use to generate the migratory birds potentially occurring in my specified
location". Please be aware this report provides the "probability of presence" of birds within the 10 km grid cell(s) that
overlap your project; not your exact project footprint. On the graphs provided, please also look carefully at the survey
effort (indicated by the black vertical bar) and for the existence of the "no data" indicator (a red horizontal bar). A high
survey effort is the key component. If the survey effort is high, then the probability of presence score can be viewed as
more dependable. In contrast, a low survey effort bar or no data bar means a lack of data and, therefore, a lack of
certainty about presence of the species. This list is not perfect; it is simply a starting point for identifying what birds of
concern have the potential to be in your project area, when they might be there, and if they might be breeding (which
Page 9 of 11IPaC: Explore Location resources
1/19/2021https://ecos.fws.gov/ipac/location/3TCSQCBFF5BFRHPXGLUBLEUIAU/resources
means nests might be present). The list helps you know what to look for to confirm presence, and helps guide you in
knowing when to implement conservation measures to avoid or minimize potential impacts from your project
activities, should presence be confirmed. To learn more about conservation measures, visit the FAQ "Tell me about
conservation measures I can implement to avoid or minimize impacts to migratory birds" at the bottom of your
migratory bird trust resources page.
Facilities
National Wildlife Refuge lands
Any activity proposed on lands managed by the National Wildlife Refuge system must undergo a
'Compatibility Determination' conducted by the Refuge. Please contact the individual Refuges to
discuss any questions or concerns.
THERE ARE NO REFUGE LANDS AT THIS LOCATION.
Fish hatcheries
THERE ARE NO FISH HATCHERIES AT THIS LOCATION.
Wetlands in the National Wetlands Inventory
Impacts to NWI wetlands and other aquatic habitats may be subject to regulation under Section 404 of
the Clean Water Act, or other State/Federal statutes.
For more information please contact the Regulatory Program of the local U.S. Army Corps of Engineers
District.
Please note that the NWI data being shown may be out of date. We are currently working to update our
NWI data set. We recommend you verify these results with a site visit to determine the actual extent of
wetlands on site.
This location overlaps the following wetlands:
FRESHWATER FORESTED/SHRUB WETLAND
PFO1A
PSS1A
FRESHWATER POND
PUB3Kr
RIVERINE
R2UBH
Page 10 of 11IPaC: Explore Location resources
1/19/2021https://ecos.fws.gov/ipac/location/3TCSQCBFF5BFRHPXGLUBLEUIAU/resources
Data limitations
The Service's objective of mapping wetlands and deepwater habitats is to produce reconnaissance level information
on the location, type and size of these resources. The maps are prepared from the analysis of high altitude imagery.
Wetlands are identified based on vegetation, visible hydrology and geography. A margin of error is inherent in the use
of imagery; thus, detailed on-the-ground inspection of any particular site may result in revision of the wetland
boundaries or classification established through image analysis.
The accuracy of image interpretation depends on the quality of the imagery, the experience of the image analysts, the
amount and quality of the collateral data and the amount of ground truth verification work conducted. Metadata
should be consulted to determine the date of the source imagery used and any mapping problems.
Wetlands or other mapped features may have changed since the date of the imagery or field work. There may be
occasional differences in polygon boundaries or classifications between the information depicted on the map and the
actual conditions on site.
Data exclusions
Certain wetland habitats are excluded from the National mapping program because of the limitations of aerial imagery
as the primary data source used to detect wetlands. These habitats include seagrasses or submerged aquatic
vegetation that are found in the intertidal and subtidal zones of estuaries and nearshore coastal waters. Some
deepwater reef communities (coral or tuberficid worm reefs) have also been excluded from the inventory. These
habitats, because of their depth, go undetected by aerial imagery.
Data precautions
Federal, state, and local regulatory agencies with jurisdiction over wetlands may define and describe wetlands in a
different manner than that used in this inventory. There is no attempt, in either the design or products of this
inventory, to define the limits of proprietary jurisdiction of any Federal, state, or local government or to establish the
geographical scope of the regulatory programs of government agencies. Persons intending to engage in activities
involving modifications within or adjacent to wetland areas should seek the advice of appropriate federal, state, or
local agencies concerning specified agency regulatory programs and proprietary jurisdictions that may affect such
activities.
R4SBC
R5UBH
A full description for each wetland code can be found at the National Wetlands Inventory website
Page 11 of 11IPaC: Explore Location resources
1/19/2021https://ecos.fws.gov/ipac/location/3TCSQCBFF5BFRHPXGLUBLEUIAU/resources
NCHPO HPOWEB
State of North Carolina DOT, Esri, HERE, Garmin, INCREMENT P, NGA,
USGS
Local districts & boundaries
Local individual resources & centerpoints
Local Landmark
Local Landmark, Gone
Local HD Center Point
1/19/2021 11:17:15 AM
0 0.5 10.25 mi
0 0.8 1.60.4 km
1:36,112
North Carolina State Historic Preservation Office
State of North Carolina DOT, Esri, HERE, Garmin, INCREMENT P, NGA, USGS | Esri, HERE |
DWR Pre-Fil ing Meeting Req u est Form
Contact Name *
Contact Email Addre ss *
Proje ct Owne r *
Proje ct Name *
Proje ct County *
Owne r Addre ss:*
Is this a transportation proje ct?*
Type (s) of approv al sought from the DWR:
Doe s this proje ct hav e an e xisting proje ct ID#?*
Ple ase list all e xisting proje ct ID's associate d with this proje cts.*
Do you know the name of the staff me mbe r you would like to re que st a me e ting with?
Ple ase giv e a brie f proje ct de scription be low.*
Please give a couple of dates you are available for a meeting.
Keven Arrance
karrance@hazenandsawyer.com
City of Durham, Water Management
Snow Hill Road Force Main
Durham
City
Durham
State / Province / Region
NC
Postal / Zip Code
27704
Country
USA
Street Address
1600 Mist Lake Drive
Address Line 2
Yes No
401 Water Quality Certification -
Regular
401 Water Quality Certification -
Express
Individual Permit Modification
Shoreline Stabilization
Yes No
20-241
The project consists of construction of a new sewer force main, connecting
the new Snow Hill Road Pump Station (currently under construction) to the
existing Eno River Pump Station. The proposed force main extends
approximately 2.78 miles. The proposed project generally follows either
existing sewer easements or roadway rights-of-way. A stream determination
for buffer applicability was conducted on 9/10/2020 for the project.
Installation of the proposed force main will be by open cut trenching for the
majority of the length. Trenchless installation techniques will be used to
install the crossing of the Eno River (mainstem and an oxbow).
Ple ase attach the docume ntation you would like to hav e the me e ting about.
Signature *
Submittal Date
11/4/2020
11/5/2020
11/6/2020
11/23/2020
11/24/2020
SHRFM_topo_prefiling mtg map.pdf 615.43KB
pdf only
By digitally signing below, I certify that I have read and understood that per the Federal Clean Water Act Section
401 Certification Rule the following statements:
· This form completes the requirement of the Pre-Filing Meeting Request in the Clean Water Act Section 401 Certification
Rule.
· I understand by signing this form that I cannot submit my application until 30 calendar days after this pre-filing
meeting request.
· I also understand that DWR is not required to respond or grant the meeting request.
Your project’s thirty-day clock started upon receipt of this application. You will receive notification regarding meeting location
and time if a meeting is necessary. You will receive notification when the thirty-day clock has expired, and you can submit an
application.
11/2/2020