Loading...
HomeMy WebLinkAboutWI0500113_GEOTHERMAL_20030806DIVISION OF WATER QUALITY GROUNDWATER SECTION August 6, 2003 MEMORANDUM To: From: Jay Zimmerman, L.G. Regional Groundwater Supervisor Groundwater Section Raleigh Regional Office Mark Pritzl Mark.Pritzl@ncmail.net Hydrogeological Technician II UIC Program Groundwater Section Raleigh Central Office Re: Receipt of Notification for a Closed-Loop Geothermal Water-Only Injection Well System (type 5QW injection well.) Notification to construct and operate 3 wells for a closed-loop geothermal heat pump system has been filed by Ms. Guthrie in Cary, and a copy of the Notification is enclosed for your files. This injection well system is deemed permitted by rule (NCAC Tl5A: 2C.21 l(u)2) and no regulatory action is necessary. If you have any questions, please contact me at (919) 715-6166. cc: CO-UIC Files Enclosures NORm CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES NOTIFICATION OF INTENT TO CONSTRUCT A CLOSED-LOOP GEOTHERMAL WATER-ONLY INJECTION WELL SYSTEM (GROUND COUPLED BEAT P UMP) Type SQW WeBs In Acconlance with the provisions ofNCAC Title ISA: 02C.0200 Complete application and mail to address on the back. page. This is !!!!.the proper form to be used for injection wells in an open-loop geothermal system. Do not use this form for systems that ci.-culate any substances other than water. TO: DIRECTOR, NOR1H CAROLINA DIVISION OF WATER QUALITY DATE: 8: -I . 20 o3 A. SYSTEM CLASSIFICATION Does the proposed system circulate potable water in continuous piping that completely isolates the fluid from the environment? YES _j__ If yes, then continue completing this form. NO If no, do not complete this form. Form GW-57 HP, Application For Permit To Construct And/Or Use A Well(s) For Injection With A Heat Pump System, should be completed. B. SYSTEM FLUID Will any additives be introduced to the system's circulating heat transfer fluid? This includes, but is not limited to corrosion inhibitors and/or antifreezes. YES If yes, do not complete this form. Form GW-57 HP, Application For Permit To Construct And/Or Use A Well(s) For Injection With A Heat Pump System, should be completed. NO 1_ If no, then continue completing this form. C. PROPERTY OWNER ~ §JP:J>cii~~·ti-r City: CA:t'..:J_ State: ZJ.e Code:_c3-!..--!J$~/ / ___ _ County: ~ Telephone: ---~--_.K...,!5a.-=--....,,5 .. 75..,,-=:.;j.__ ______ --;=;;,.... 8 D. STATUS OF PROPERTY OWNER l> C: Ver.3/01 Private: .1_ State: Federal: Municipal: __ GW/UIC-57 CL Commercial: Native American Lands: -~---.-, ... ·i;-.~£1:"" Page 1 en I CJl -0 3: ~ w 0) of4 -· ., • > ; , ;:-t . -~ -::-:-.-:::.;i, ,_ fTJ ......... ;:o~- U':->'" f'TI :::0 r, C, :.::: E. FACILITY (SITE) DATA F. G. (Fill out ONLY if the Status of Owner is Federal, State, Municipal or Commercial). Name of Business or Facility: ____________________ _ Address: ___________________________ _ City: ________ State: __ Zip Code: ____ County: ____ _ Telephone: _________ Contact Person: ___________ _ Standard Industrial Code(s), SIC, which describes commercial facility: _______ _ HEAT PUMP CONTRACTOR DATA Name: f V ll'JUfo (; uS-r S~ fl. v1 C t:-~ Address: e · o. &0)t 3b!2.. City: f:\f fl' State: IUC.. Zip Code: .t."7s'oz County: CHlfl'fflll"" Telephone: till q-~'1-"71'1 o Contact Person: 6, "' E"'•"''-ec.,s-r CONSTRUCTION DATA (check one) EXISTING WELL(S) being proposed for use as a ground-coupled heat pump well(s). Provide the infonnation in (1) through (3) below to the best of your knowledge. Attach a copy of Form GW-1 (Well Construction Record) if available. PROPOSED WELL(S) to be constructed for use as a ground-coupled heat pump well(s). Provide the information in (1) through (3) below as PROPOSED construction specifications. Submit Fonn GW-1 after construction. (1) WellDrillingContractor'sName: LAk~ Vt\u.f''1 t.t}e« f.o . .:C,-.>C . NC Contractor Certification number:_~l ..;_2____.;.b_'I ____________ _ Date to be constructed: 1-ll -oj Number of borings: -=3 ______ _ ua'' Approximate depth of each boring (feet): __ ..... 1_....;..-,_., ___________ _ (2) Well casing: Is the well(s) cased? (3) NOTE: (a) YES , If yes, then provide the casing information below. Type: Galvanized steel __ Black steel __ Plastic __ Other (specify) ____ _ Casing depth: From ___ to ___ ft. (reference to land surface) Casing extends above ground ____ inches (b) NO .:i:,_ Grout (grout the vertical length of the borehole to a minimum depth of 20 feet b.1.s. ): (a) Grout type: Cement__ Bentonite ..K_ Other (specify) ______ _ (b) Grouted surface and grout depth (reference to land surface): __ around closed loop piping; from O to 100 (feet). __ around well casing; from __ to __ (feet). ;:;~~:~t::~::i!%~:~~:;~:~~-r;;:a~;AB~O~T==i~:~IN~.;~~; Ver.3/01 ,:.;GW/UIC-57 CL Page 2 of4 H. INJECTION-RELATED EQUIPMENT Attach a diagram showing the engineering layout of the injection equipment and exterior piping/tubing associated with the injection operation. The manufacturer's brochure may provide supplementary information. I. LOCATION OF WELL(S) Attach two maps. (1) Include a site map (can be drawn) showing: buildings, property lines surmce water bodies, potential sources of groundwater contamination and the orientation of and distances between the proposed well(s) and any existing well(s) or waste disposal facilities such as septic tanks or drain fields located within 200 feet of the ground-coupled beat pump well system. Label all features clearly and include a north arrow. (2) location map referencing the site to two nearby permanent reference points (such as roads, streams and highway intersections). J. PERMIT LIST: Attach a list of all permits or construction approvals that are related to the site. Examples include: (1) Hazardous Waste Management program pennits under RCRA (2) NC Division of Water Quality Non-Discharge permits (3) Sewage Treatment and Disposal Pennits K.. CERTIFICATION "I hereby certify, under penalty of law, that I have personally examined and am familiar with the information submitted in this document and all attachments thereto and that, based on my inquiry of those individuals immediately responsible for obtaining said information, I believe that the information is true, accurate and complete. I am aware 1hat there are significant penalties, including the possibility of fines and imprisonment. for submitting false infonnation. I agree to construct, operate, maintain, repair, and if applicable, abandon the ground-source heat pump system and all related appurtenances in Ver.3/01 accordance with the approved specifications and itions of the Permit" _.-.s:"; . ..:.!-~' .. :. If authorized agent is acting on behalf of the well owner, please supply a letter signed by the owner authorizing the above agent. Page 3 of4 L. CONSENT OF PROPERTY OWNER (Owner means any person who holds the fee or other property rights in the well being constructed. A well is real property and its construction on land rests ownership in the landowner in the absence of contrary agreement in writing.) If the property is owned by someone other than the applicant, the property owner hereby consents to allow the applicant to construct each injection well as outlined in this application and that it shall be the responsibility of the applicant to ensure that the ground -source heat pump system's well(s) conforms to the Well Constriction Standards (Title 15A NCAC 2C .0200) (Signet uProperty Owner If Different From Applicant) Please return two copies of the completed Application package to: UIC Program Groundwater Section North Carolina DENR-DWQ 1636 Mail Service Center Raleigh, NC 27699-1636 Telephone (919) 715-6165 Ver.3/O1 GWNIC-57 CL Page 4 of 4 WV" P+, 164.960 &ova fwd. Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P. E. Director Division of Water Quality Coleea H. Sullins, Deputy Director Division of Water Quality August 5, 2003 Ms. Ruth L. Guthrie 146 Lochwood West Cary, NC 27511 RE: Notification of intent to construct Type 5QW injection wells Dear Ms. Ruth: In accordance with the notification you submitted to the UIC Program on August 5, 2003, the Groundwater Section acknowledges your intent to construct 3 closed -loop geothermal water -only injection wells for the operation of a ground -source heat pump. The system as described in your notification is deemed permitted by rule (North Carolina Administrative Code Title 15A: 2C.0211(u)(2)) and will not require an injection well permit from the state, but you should check with your county health department prior to constructing the system because they may have additional construction or permitting requirements for this type of system. If you modify your system at any time, please contact the Groundwater Section to verify compliance with applicable rules. Thank you for submitting this notification. If you have any questions regarding geothermal heat pump wells or injection well rules please contact me at (919)715-6166. Sincerely, Mark Pritzl Hydrogeological Technician UIC Program cc: RRO-UIC files CO-UIC files 474 N. C. Division of Water Quality J Groundwater Section 1636 Mail Service Center Raleigh, N.C. 27699-1636 Phone: (919) 733-3221 Fax: (919) 715-0588 Internet: httpilgw.ehnr.state.nc.us Customer Service 1-877-23-6748