HomeMy WebLinkAboutWI0500112_GEOTHERMAL_19980921GROUNDWATER SECTION
September 21, 1998
MEMORANDUM
To: fun Greer
Groundwater Section
Raleigh Regional Office
From: Mark Pritzl t1-/J Mark_Pritzl@mail.state.nc.us
Hydrogeological Technician II
illCGroup
Groundwater Section
Raleigh Central Office
Re: Receipt of Notification for a Closed-Loop Geothermal Water-Only Injection Well System.
Notification to construct and operate an injection well system for a geothermal heat pump system
has been filed by William J. Kaluza of Raleigh, North Carolina and a copy of the Notification is
enclosed for your files. This injection well system is deemed permitted by rule (NCAC TISA:
2C.21 l(u)2) and no regulatory action is necessary. If you have any questions, please contact me
at (919) 715-6166 or Amy Axon at (919) 715-6165.
cc: UIC Files
RROFiles
Enclosures
NCDENR
JAMES B. HUNTJR-
GOVERNOIi
WAYNE MCDEVITT
SECRETARY
A. PRESTON HOWARD,
JR., RE.
DIRECTOR
NORTH CAROLINA DEPARTMENT OF
ENVIRONMENT AND NATURAL RESOURCES
GROUNDWATER SECTION
September 1S, 1998
William 7. Kaluza
1248 Barclay Manor Way
Raleigh, NC 27614
Dear Mr. Kaluza:
DIVISION OF WATER QUALITY
In accordance with the notification submitted on your behalf of Bowman's Mechanical
Services dated September 14, 1998; the Groundwater Section acknowledges your
intention to construct closed -loop geothermal water -only injection wells for the
operation of a ground -source heat pump. The system as described in your notification
will not require an injection well permit and is deemed permitted by rule (North
Carolina Administrative Code Title 15A: 2C.4211(u)(2). The Underground Injection
Control Group has added your site to our inventory. If you modify your system, please
contact the Groundwater Section to verify compliance. Thank you for submitting this
notification.
If you have any questions regarding geothermal heat pump weals please feel free to
contact me at (919) 715-6166 or Amy Axon at (919) 715-6165.
Sincerely,
Mark Pritzl
Hydrogeological Technician II
Underground Injection Control Program
cc: CAC Files
RRO Files
GROUNDWATER SECTION
P.0 BOX 29578, RALEMH, NC 27525-057B - 2728 CAPITAL BLVD., RALEIGH, NC, 27604
PHONE 91 9.733-3ZZ I FAX 91 9.715-0508
AN EQUAL OPPORTUNITY/AFFIRMATIVE ACTION EMPLOYER - 50% RECYCLEAIT0% POST -CONSUMER PAPER
NORTH CAROLINA
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
NOTIFICATION OF INTENT TO CONSTRUCT A CLOSED -LOOP
GEOTHERMAL WATER -ONLY INJECTION WELL SYSTEM
(GROUND COUPLED HEAT• PUMP)
Type 5QW Wells
In Accordance with the provisions ofNCAC Title 15A: 02C.0200
Complete application and mail to address on the back page.
This is not the proper form to be used for injection wells in an open -loop geothermal system,
Do not use this form for systems that circulate anv substances other than water.
TO: DIRECTOR, NOS RTH CAROLINA DIVISION OF WATER QUALITY
DATE: -, 4 . 19 9.
L0
co
cn
rn
A. SYSTEM CLASSIFICATION Does the proposed system circulate potable water in continuous
piping that completely isolates the fluid from the environment?
YES V If yes, then continue completing this form.
NO If no, do not complete this form. Form GW-57 HP, Application For' -
Permit To Construct And/Or Use A Well(s) For Injection With A Heat
Pump System, should be completed.
B. SYSTEM FLUID Will any additives be introduced to the system's circulating heat transfer
fluid? This includes, but is not limited to corrosion inhibitors and/or antifreezes.
YES
NO
C. PROPERTY OWNER
If yes, do not complete this form, Form GW-57 HP, Application For
Permit To Construct And/Or Use A Well(s) For Injection With A Heat
Pump System. should he completed.
If no, then continue completing this form.
Name: y�/,/If �r�.�7 ,J A/4I01. c,
Address: s! F I?a r.. Ix, /4 a,, ;,-
City: Rif, Ie sy I State: Zip Code: j
County: Telephone: `ii Sjj ? '� yide , G i
STATUS OF PROPERTY OWNER
Private: I Federal:
State:
Commercial:
Municipal: Native American Lands:
GW-57 CL (May 1998)
Page 1 of 4
. .
E. FACILITY (SITE) DATA
F.
G.
(Fill out ONLY if the Status of Owner is Federal, State, Municipal or Commercial).
Name of Business or Facility: ______________________ _
Address: ------------------------------City: _________ State: __ Zip Code: _____ County: ____ _
Telephone: __________ Contact Person: ____________ _
Standard Industrial Code(s), SIC, which describes commercial facility: ---------
HEAT PUMP CONTRACTOR DATA
Name: ~~ /lJedt~ ~
Address: 1-Z.l 'J .S::!ucd ,·vgot J)r.
City: VlJ\.u State:~. Zip Code: ;l lS"l l County: W,.Ke.,
Telephone:\ q \C-\-4~l-4S't>'i Contact Person: _.s+eve ___ &~u_/Yl_tt_,J ______ _
<,Wt-17Z.-2-1S't
CONSTRUCTION DATA (check one)
(1)
EXISTING WELL(S) being proposed for use as a ground-coupled heat pump
well(s). Provide the information in (1) through (4) below to the best of your
knowledge. Attach a copy of Form GW-1 (Well Construction Record) if available.
PROPOSED WELL(S) to be constructed for use as a ground-coupled heat pump
well(s) . Provide the information in (I) through (4) below as PROPOSED
construction specifications. Submit Form GW-1 after construction.
Well Drilling Contractor's Name: B;nJ's lJel 11),;\\,',vj 1 T,.JC .
NC Driller Registration number: ,s-ttl{
Date to be constructed: ~--/-9'1 Number of borings: 4
Approximate depth of each boring (feet):_5~0_0_' ______________ _
(2) Well casing: Is the well(s) cased?
(a) YES If yes, then provide the casing information below.
Type: Galvanized steel __ Black steel __ Plastic __ Other (specify) _____ _
Casing depth: From ___ to ___ ft. (reference to land surface)
Casing extends above ground ____ inches
(b) NO ~
(3) Grout (grout the vertical length of the borehole to a minimum depth of 20 feet b.l.s.):
NOTE:
(a) Grout type: Cement__ Bentonite ~ Other (specify) _______ _
(b) Grouted surface and grout depth (reference to land surface):
v around closed loop piping; from O to So (feet).
__ around well casing; from __ to __ (feet).
THE WELL DRILLING CONTRACTOR CAN SUPPLY THE DATA FOR EITHER EXISTING OR
PROPOSED WELLS IF THIS INFORMATION IS UNAVAILABLE BY OTHER MEANS.
GW-57 CL (May 1998) Page 2 of 4
:
X
H. INJECTION-RELATED EQUIPMENT
Attach a diagram showing the engineering layout of the injection equipment and exterior piping/tubing
associated with the injection operation. The manufacturer's brochure may provide supplementary
information.
I. LOCATION OF WELL(S) Attach two maps.
( 1) Include a site map ( can be drawn) showing: buildings, property lines surface water bodies,
potential sources of groundwater contamination and the orientation of and distances between
the proposed well(s) and any existing well(s) or waste disposal facilities such as septic tanks
or drain fields located within 200 feet of the ground-coupled heat pump well system. Label all
features clearly and include a north an-ow.
(2) location map referencing the site to two nearby permanent reference points (such as roads,
streams and highway intersections).
J. PERMIT LIST: Attach a list of all permits or construction approvals that are related to the site.
K.
Examples include:
(1) Hazardous Waste Management program permits under RCRA
(2) NC Division of Water Quality Non-Discharge permits
(3) Sewage Treatment and Disposal Permits
CERTIFICATION
"I hereby certify, under penalty of law, that I have personally examined and am familiar with the
information submitted in this document and all attachments thereto and that, based on my inquiry of
those individuals immediately responsible for obtaining said information, I believe that the information
is true, accurate and complete. I am aware that there are significant penalties, including the possibility
of fines and imprisonment, for submitting false information. I agree to construct, operate, maintain,
repair, and if applicable, abandon the ground-source heat pump system and all related appurtenances in
accordance with the approved specifications and conditions of the Permit."
If authorized agent is acting on behalf of the well owner,
please supply a letter signed by the owner
authorizing the above agent.
GW-57 CL (May 1998) Page 3 of4
X L. CONSENT OF PROPERTY OWNER (Owner means any person who holds the fee or other property
rights in the well being constructed. A well is real property and its construction on land rests
ownership in the landowner in the absence of contrary agreement in writing.)
If the property is owned by someone other than the applicant, the property owner hereby consents to
allow the applicant to construct each injection well as outlined in this application and :that it shall be
the responsibility of the applicant to ensure that the ground-source heat pump system's well(s)
conforms to the Well Construction Standards (Title 15A NCAC 2C .0200)
(Signature Of
Please return two copies of the completed Application package to:
UIC Program
Groundwater Section
North Carolina DENR-DWQ
P .0. Box 29578
Raleigh, NC 27626-0578
Telephone (919) 715-6165
GW-57 CL (May 1998) Page 4 of4
vro;
anQ-aU
®4.�3
ltd
1
1
y Maw?, Lam+1-1
exri'r% s Q Ste'sz w-,
.2
cs
Q
Nel