Loading...
HomeMy WebLinkAboutwq0042330_Application (FTSE)_20210208DWR Division of Water Resources Qr�r rvi d,-)N 3'7 d 1 ` ` r ) t sT ) Stael f North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: ig IQI O co30 (to be completed by DWR) Ali items must be completed or the application will be returned I- APPLICANT INFORMATION: 1. Applicant's name: City of Wilson, North Carolina (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ® Municipal ❑ Other 3. Signature authority's name: W.T. Bass, IV, P.E. per 15A NCAC 02T .0106(b) Title: Public Works Director 4. Applicant's mailing address: 1800 Herring Avenue E / P.O. Box 10 City: Wilson State: North Carolina Zip: p: 27894-0010 ' "f 0 v 5. Applicant's contact information: /� -h loft._ , K , , 1 '„ti Phone number: (IQ) 399-2467 Email Address: bbassc ..wilsonnc.org f -f-: A II. PROJECT INFORMATION: �'�'S ro ,, 0 1. Project name: City of Wilson - Lower Bloomery Swamp Sewer Improvements w° oo. "n � 2. Application/Project status: ❑ Proposed (New Permit) ® Existing Permit/Project If a modification, provide the existing permit number: WQ007486 and issued date: July 9, 1982 tr`�a l• 5' co 0 If new construction but part of a master plan, provide the existing permit number: WQ00 m pa m 3. County where project is located: Wilson O co 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.7101` Longitude: -77.9534 ' A c9 o 5. Parcel ID (if applicable): 3711-00-6720.000 — (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: I. Professional Engineer: W. Landon Younce, PE License Number: 030003 Firm: Green Engineerine, PLLC Mailing address: 303 Goldsboro St E r' P.O. Box 609 City: Wilson State: North Carolina Zip: 27893- Phone number: (252) 237-5365 Email Address: Lyounec0nreeneng.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Hominy Creek Water Reclamation Facility Permit Number: NC0023906 Owner Name: City of Wilson, North Carolina V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): I. Permit Number(s): WQ Downstream (Receiving) Sewer Size: 30- inch System Wide Collection System Permit Number(s) (if applicable): WQCS _ Owner Name(s): City of Wilson FORM: FTA 04-16 Page 1 of 5 THE COMPLETED APPLICATION PACKAGE INCLDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE: REGIONAL OFFICE ADDRESS COUNTIES SERVED Asheville Regional Office 2090 US Highway 70 Swannanoa, North Carolina 28778 (828) 296-4500 (828) 299-7043 Fax Avery, Buncombe, Burke, Caldwell, Cherokee, Clay, Graham, Haywood, Henderson, Jackson, Macon, Madison, McDowell, Mitchell, Polk, Rutherford, Swain, Transylvania, Yancey Water Quality Section Fayetteville Regional Office 225 Green Street Suite 714 Fayetteville, North Carolina 28301-5094 (910) 433-3300 (910) 486-0707 Fax Anson, Bladen, Cumberland, Hametl, Hoke, Montgomery, Moore, Robeson, Richmond, Sampson, Scotland Water Quality Section Mooresville Regional Office 610 E. Center Avenue Mooresville, North Carolina 28115 (704) 663-1699 (704) 663-6040 Fax Alexander, Cabarrus, Catawba, Cleveland, Gaston, Iredell, Lincoln, Mecklenburg, Rowan, Stanly, Union Water Quality Section Raleigh Regional Office 1628 Mail Service Center Raleigh, North Carolina 27699-1628 (919) 791-4200 (919) 788-7159 Fax Chatham, Durham, Edgecombe, Franklin, Granville, Halifax, Johnston, Lee, Nash, Northampton, Orange, Person, Vance, Wake, Warren, Wilson Water Quality Section Washington Regional Office 943 Washington Square Mall Washington, North Carolina 27889 (252) 946-6481 (252) 975-3716 Fax Beaufort, Bertie, Camden, Chowan, Craven, Currituck, Dare, Gates, Greene, Hertford, Hyde, Jones, Lenoir, Martin, Pamlico, Pasquotank, Perquimans, Pitt, Tyrrell, Washington, Wayne Water Quality_ Section Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, North Carolina 28405 (910) 796-7215 (910) 350-2004 Fax Brunswick, Carteret, Columbus, Duplin, New Hanover, Onslow, Pender Water Quality Section Winston-Salem Regional Office 450 W. Hanes Mill Road Suite 300 Winston-Salem, North Carolina 27105 (336) 776-9800 Alamance, Alleghany, Ashe, Caswell, Davidson, Davie, Forsyth, Guilford, Rockingham, Randolph, Stokes, Suny, Watauga, Wilkes, Yadkin Water Quality Section INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page 3 of 3 VI. GENERAL REQUIREMENTS I. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®N,'A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes 0No ®NSA 3. If the Applicant is a Home. Property Owners' Association, has an Operational Agreement (FORM: I-1OA) been attached? ❑ Yes ❑No ®N/A 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Residential Leased ❑ Retail with food preparation/service ❑ School / preschool / day care ❑ Medical / dental i veterinary facilities ❑ Food and drink facilities 0 Church O Businesses / offices / factories ❑ Nursing Home ❑ Car Wash ❑ Hotel and/or Motels ❑ Swimming Pool +Clubhouse 0 Swimming Pool/Filter Backwash ® Other (Explain in Attachment) 5. Nature of wastewater : 100 % Domestic/Commercial % Commercial _ % Industrial (Sec I5A NCAC 02T .0103(20)) �Is there a Pretreatment Program in effect? ® Yes ❑ No 6. Has a flow reduction been approved under I5A NCAC 02T .0114(f)? ❑ Yes ® No If yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f) Daily Design Flow Lb No. of Units Flow MA - All Flows Exit►:nc as Permitted gal/ N/A GPD gal/ GPD gal/ GPD gal? GPD gall GPD gal! GPD Total NIA GPD a See I5A NCAC 02T .0114(b), (d). (c)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.0 I 14] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. S. Wastewater generated by project: 0 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: Rehabilitation or replacement of existing sewer with no new flow expected 0 Other (Explain): FORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 24"0 5,495 PVC 24"0 1,485 DIP Wit. i0"0 40 DIP 8"0 145 DIP • Section II & I11 of the MDC for Permitting of Gravity Sewers contains information related to design criteria • Section 111 contains information related to minimum slopes for gravity sewer(s) • Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & M DC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: N+A 2. Approximate Coordinates (Decimal Degrees): Latitude: . Longitude: - s_ 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material N/A N/A N/A 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B): Z Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day Must be permanent to facility Or if the pump station has an average daily flow Tess than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - I5A NCAC 02T .0305(h)( 1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): z It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. D If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: Fi'A 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(4 I. Does the project comply with all separations found in 1 5A NCAC 02T .0305(f) & (e) 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: ® Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches D I 5A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(t) cannot be achieved. **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage If noncompliance with 02T.0305(f) or (g), see Section X of this application Does the project comply with separation requirements for wetlands? (50 feet of separation) ❑ Yes ® No ❑ N!A i- See the Division's draft separation requirements for situations where separation cannot be meet No variance is required if the alternative design criteria specified is utilized in design and construction As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per I5A NCAC 02B .0200? ® Yes ❑ No ❑ N: A This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project require coverage,`authorization under a 404 Nationwide or individual permits or 401 Water Quality Certifications? Information can be obtained from the 401 & Buffer Permitting, Branch ®Yes ❑No 5. Does project comply with I5A NCAC 02T.0105(c)(6) (additional permits,'certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6) directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No ❑ NIA i- If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with I5A NCAC 02T, the Minimum Dcsi >n Criteria for the Permittine of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. Professional Engineer's Certification: I, W Landon Younce, FE attest that this application for (Professional Engineer's name from Application Item I11.1.) Lower Bloomery Swamp Sewer Improvements has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes I43-215.6A and I43-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. Sr Ac North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per I5A NCAC 02T .0106(b): I, WT Bass, IV, PE — Public Works Director (Signature Authority's name & title from Application Item 1.3.) Lower Bloomery Swamp Sewer Improvements has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. 1 also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. attest that this application for NOTE — In accordance with General Statutes 143-215.6A and I43-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: 11ZfVZ l FORM: FTA 04-16 Page 5 of 5 USGS TOPOGRAPHICAL MAP LOWER BLOOMERY SWAMP SEWER IMPROVEMENTS LAT: 35.70001, LONG: -77.953 (LOCATION OF EX. LIFT STATION) 4• • • • 7 Q) J II II Ill een Engineering Green Engineering, PLLC Water, Wastewater, Surveying Planning, Project Management 303 Goldsboro Street East • PO Box 609 • Wilson, NC 27894 TEL 252.237.5365 • FAX 252.243.7489 WWW.GREENENGINEERING.COM February 1, 2021 NCDEQ Water Quality Regional Operations Section Raleigh Regional Office 3800 Barrett Drive Raleigh, North Carolina 27609 Attention: Mr. Scott Vinson Water Resources Regional Supervisor SUBJECT: Fast -Track Sewer System Extension Application Lower Bloomery Swamp Sewer Improvements City of Wilson, North Carolina PN: 13-059 Dear Mr. Vinson: NC Dept ofEnvlronmental Quality FEB` 8 2991 Raleigh Regional Office Back in 2014, the City of Wilson acquired our services to design gravity sewer improvements of the Lower Bloomery Swamp interceptor. After completion of the design phase, the City chose to table the project for future budgeting. All existing flows contributing to the gravity system flow downstream and are collected at the City's Contentnea Pump Station. That pump station is not being upgraded at this time. Please find attached two (2) copies of each of the following documents for your review and approval: • Fast -Track Sewer Application Form — One (1) original and one (1) copy • 8 %" x II" copy of project location on USGS Quadrangle Maps • Street Level Aerial Photography for location referencing Also, please find attached check in the amount of $480.00 to cover the application review fee. If you should have any questions or require additional information, please call. Respectfully, W'Landon9 ounce, P.E. Enclosures: As stated. cc: Mr. W. T. Bass, IV, P.E. — Public Works Director, City of Wilson Mr. Barry Parks — Director of Water Resources, City of Wilson W.• WILSOlI3O$9`.Offece'PER2 TS'Scwer Pennirxatt vtnson • NCDEQ - fast track sewer Itg2-1-2021).doc USGS TOPOGRAPHICAL MAP LOWER BLOOMERY SWAMP SEWER IMPROVEMENTS LAT: 35.70001, LONG: -77.953 (LOCATION OF EX. LIFT STATION c cu C